2
Call your Account Representative for floor stock availability or go on-line at www.independencetube.com. CSA G40.21 50W (350W) INDEPENDENCE TUBE is now manufacturing cold-formed HSS tubing to the Canadian specification CSA G40 50W, or what is commonly referred to as 350W. 6226 West 74th Street Chicago, IL 60638 1-800-376-6000 1-708-563-1950 (FAX) www.independencetube.com Comparison of ASTM A500 Grade C to CSA G40.21 50W Round Sections Mechanical Properties ASTM A500 Grade C CSA G40.21 50W O.D. Tolerance ASTM A500 Grade C CSA G40.21 50W Yield Strength 46,000 psi min 50,000 psi min >1.9"-2.5" Incl. +/-.75% +/-.020" Tensile Strength 62,000 psi min 65,000 psi min Over 2.5"-3.5" Incl. +/-.75% +/-.030" Elongation in 2" 21 min* 22 min* Over 3.5"-5.5" Incl. +/-.75% +/-.040" Over 5.5" +/-.75% +/-1% Comparison of ASTM A500 Grade C to CSA G40.21 50W Square & Rectangular Sections Mechanical Properties ASTM A500 Grade C CSA G40.21 50W O.D. Tolerance ASTM A500 Grade C CSA G40.21 50W Yield Strength 50,000 psi min 50,000 psi min >2.5" Incl. +/-.020" +/-.020" Tensile Strength 62,000 psi min 65,000 psi min Over 2.5"-3.5" Incl. +/-.025" +/-.030" Elongation in 2" 21 min* 22 min* Over 3.5"-5.5" Incl. +/-.030" +/-.040" Over 5.5" +/-1% +/-1% ASTM A500 Grade C CSA G40.21 50W Wall Thickness +/-10% +10% / -5% Mass N/A +10% / -3.5% Straightness (Max allowed) 1/8" X length (in feet) divided by 5 1/8" X length (in feet) divided by 5 Squareness +/- 2 degrees +/- 2 degrees January 2017

CSA G40.21 50W (350W) - Independence Tube · Call your Account Representative for floor stock availability or go on-line at . CSA G40.21 50W (350W) INDEPENDENCE TUBE is now

  • Upload
    lamdan

  • View
    222

  • Download
    0

Embed Size (px)

Citation preview

Call your Account Representative for floor stock availability or go on-line at www.independencetube.com.

CSA G40.21 50W (350W)INDEPENDENCE TUBE is now

manufacturing cold-formed HSS

tubing to the Canadian specification

CSA G40 50W, or what is

commonly referred to as 350W.

6226 West 74th StreetChicago, IL 60638

1-800-376-60001-708-563-1950 (FAX)

www.independencetube.com

Comparison of ASTM A500 Grade C to CSA G40.21 50W Round Sections

Mechanical Properties

ASTM A500 Grade C

CSA G40.21 50W O.D. ToleranceASTM A500

Grade CCSA G40.21 50W

Yield Strength 46,000 psi min 50,000 psi min >1.9"-2.5" Incl. +/-.75% +/-.020"

Tensile Strength 62,000 psi min 65,000 psi min Over 2.5"-3.5" Incl. +/-.75% +/-.030"

Elongation in 2" 21 min* 22 min* Over 3.5"-5.5" Incl. +/-.75% +/-.040"

Over 5.5" +/-.75% +/-1%

Comparison of ASTM A500 Grade C to CSA G40.21 50W Square & Rectangular Sections

Mechanical Properties

ASTM A500 Grade C

CSA G40.21 50W O.D. ToleranceASTM A500

Grade CCSA G40.21 50W

Yield Strength 50,000 psi min 50,000 psi min >2.5" Incl. +/-.020" +/-.020"

Tensile Strength 62,000 psi min 65,000 psi min Over 2.5"-3.5" Incl. +/-.025" +/-.030"

Elongation in 2" 21 min* 22 min* Over 3.5"-5.5" Incl. +/-.030" +/-.040"

Over 5.5" +/-1% +/-1%

ASTM A500 Grade C CSA G40.21 50W

Wall Thickness +/-10% +10% / -5%

Mass N/A +10% / -3.5%

Straightness (Max allowed) 1/8" X length (in feet) divided by 5 1/8" X length (in feet) divided by 5

Squareness +/- 2 degrees +/- 2 degrees

January 2017

Call your Account Representative for floor stock availability or go on-line at www.independencetube.com.

CSA G40.21 50 W (350W)

6226 West 74th StreetChicago, IL 60638

1-800-376-60001-708-563-1950 (FAX)

www.independencetube.com

Corner Radii (Wall thickness in inches) MaximumPerimeter

to 24" incl.

Perimeter

over 24"

To .109" incl. 3t .218" —

Over .109" – .134" incl. 3t .268" —

Over .134" – .156" incl. 3t .312" —

Over .156" – .188" 3t .470" —

Over .188" – .250" 3t .625" .750"

Over .250" – .313" 3t .785" .940"

Over .313" – .375" 3t .938" 1.125"

Over .375" – .500" 3t 1.250" 1.500"

Over .500" 3t — 3t

Comparison of ASTM A500 Grade C to CSA G40.21 50W Square & Rectangular Sections

ASTM A500 Grade C CSA G40.21 50WTwist (max 3 feet of length)

1.5 and under .050" .050"

Over 1.5 – 2.5 incl. .062" .062"

Over 2.5 – 4.0 incl. .075" .075"

Over 4.0 – 6.0 incl. .087" .087"

Over 6.0 – 8.0 incl. .100" .100"

Over 8.0 .112" .112"

NOTE: Tolerance includes allowance for convexity and concavity. For rectangular sections, the tolerance calculated for the larger flat dimension shall also apply to the smaller flat dimension. This tolerance shall be increased by 50% when applied to the smaller dimension for rectangular sections whose ratio of cross-sectional dimensions is between 1.5 and 3, and by 100% when this ratio exceeds 3.

January 2017