    DRG. No.

    RATING :

    1 R0

    2 R0

    3 R0

    4 R0

    5 LV BUSDUCT R0

    6 HV CABLE BOX R0

    7 GA OF MARSHALLING BOX R0

    8 MARSHALLING BOX WIRING DIAGRAM R0

    9 FOUNDATION R0

    10 GTP R0

    11 GTP R0

    1

    Date Date 11.04.14

    FORM NO:FM/TF/PMG/34

    FIRST SUBMISSIONGA OF TRANSFORMER (ADA1720007) 31GA1319

    ADA1720008 FIRST SUBMISSION

    31CD1445

    FIRST SUBMISSION

    31CD1448 FIRST SUBMISSION

    CUSTOMER DRAWING LISTPCN

    4500kVA 33/0.433 kV 3 PHASE TRANSFORMER

    ADA1720007

    ADA1720008

    TRANSFORMER DIVISION 41CL0598 R0

    SR.

    No.DESCRIPTION DRG. No. REV. STATUS

    P.O No. :

    CUSTOMER : M/s. SIEMENS LTD.

    GA OF TRANSFORMER (ADA1720008) 31GA1320 FIRST SUBMISSION

    RATING & DIAGRAM PLATE (ADA1720007) 31RD1084 FIRST SUBMISSION

    31CD1447 FIRST SUBMISSION

    31CD1446

    31CD1449 FIRST SUBMISSION

    ADA1720007

    FIRST SUBMISSION

    FIRST SUBMISSION

    DNA KVRR SP

    Sign

    RATING & DIAGRAM PLATE (ADA1720008) 31RD1085 FIRST SUBMISSION

    Rev.no Revision Note sign 11.04.14 11.04.14

  • 7/25/2019 Customer Drawings ADA1720007 08

    2/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    3/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    4/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    5/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    6/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    7/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    8/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    9/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    10/12

  • 7/25/2019 Customer Drawings ADA1720007 08

    11/12

    Doc ADA1720008

    DATE : 11.04.2014 REV NO 0

    SR.NO DESCRIPTION UOM PARTICULARS

    1 Name Of Manufacturer RAYCHEM RPG (P) LTD

    2 Service OUTDOOR

    3 Reference Standard IS 2026,2011

    4 Kva Rating ( Hv / Lv W inding ) KVA 4500

    5 Rated Voltage

    A. H.V. Winding VOLT 33000B. L.V. Winding VOLT 433

    6 Rated Frequency Hz 50

    7 No Of Phases 3

    8 Connections With Symbol

    A. H.V. Winding Delta

    B. L.V. Winding Star

    9 Vector Group Dyn11

    10 Tappings On Hv

    A. Type Off Circuit Tap Changer

    B. Number Of Steps 4 steps 5 position

    C. Tap Range +5%to-5% @ 2.5%

    11 Winding Material COPPER

    12 Insulation Class A

    13Type Of Cooling

    ONAN

    14 Temp. Rise Over Reference Amb. Temp. Of 50 C

    A. In Oil By Thermometer C 55

    B. In W inding By Resistance C 55

    15 Total Loss At Rated Voltage On Principal Tappings & Rated Frequency @75C

    Component Losses

    A.No Load Loss (Max) KW 5.00

    B.Load Loss (Max) KW 38.0

    16 Impedance At Principal Tap (+/- IS tol) % 7.15

    A. Reactance % 7.10

    B. Resistance At 75C % 0.84

    17 Insulation Level

    A.Separate Source Power Frequency Voltage Withstand

    I. Hv Winding KV RMS 70

    Ii.Lv Winding KV RMS 3

    B.Full Wave Lighting Impulse Withstand Voltage

    I. Hv Winding KV PEAK 170Ii.Lv Winding KV PEAK NA

    18 Efficiency At 75 C & Unity Power Factor

    A. At Full Load % 99.05

    B. At 3/4 Full Load % 99.22

    C. At 1/2 Full Load % 99.36

    19 Regulation At Full Load & 75C

    A. At Unity Power Factor % 1.10

    B. At 0.8 Power Factor Lagging % 5.07

    B. At 0.9 Power Factor Lagging % 3.41

    20 Terminal Arrangements

    A. Hv Side BARE BUSHING

    B. Lv Side Bus duct flange

    21 Approx. Weight

    A. Core & Winding Kg 4700

    B. Tank & Fittings Kg 3300

    C. Oil Kg 2000

    D.Total Mass Kg 10000

    C.Oil Ltrs. 2440

    Note:

    1. Efficiency and regulation values are calculated based on nominal values of NLL,LL & %Z.

    2. Weights and dimensions are subject to +/- 10% tol

    GUARANTEED TECHNICAL PARTICULARS

    ared by : PD Approved by : SP

    Page 1 of 1

    FORM NO.FM/TF/PMG/13

  • 7/25/2019 Customer Drawings ADA1720007 08

    12/12

    Doc ADA1720007

    DATE : 11.04.2014 REV NO 0

    SR.NO DESCRIPTION UOM PARTICULARS

    1 Name Of Manufacturer RAYCHEM RPG (P) LTD

    2 Service INDOOR

    3 Reference Standard IS 2026,2011

    4 Kva Rating ( Hv / Lv W inding ) KVA 4500

    5 Rated Voltage

    A. H.V. Winding VOLT 33000B. L.V. Winding VOLT 433

    6 Rated Frequency Hz 50

    7 No Of Phases 3

    8 Connections With Symbol

    A. H.V. Winding Delta

    B. L.V. Winding Star

    9 Vector Group Dyn11

    10 Tappings On Hv

    A. Type Off Circuit Tap Changer

    B. Number Of Steps 4 steps 5 position

    C. Tap Range +5%to-5% @ 2.5%

    11 Winding Material COPPER

    12 Insulation Class A

    13Type Of Cooling

    ONAN

    14 Temp. Rise Over Reference Amb. Temp. Of 50 C

    A. In Oil By Thermometer C 55

    B. In W inding By Resistance C 55

    15 Total Loss At Rated Voltage On Principal Tappings & Rated Frequency @75C

    Component Losses

    A.No Load Loss (Max) KW 5.00

    B.Load Loss (Max) KW 38.0

    16 Impedance At Principal Tap (+/- IS tol) % 7.15

    A. Reactance % 7.10

    B. Resistance At 75C % 0.84

    17 Insulation Level

    A.Separate Source Power Frequency Voltage Withstand

    I. Hv Winding KV RMS 70

    Ii.Lv Winding KV RMS 3

    B.Full Wave Lighting Impulse Withstand Voltage

    I. Hv Winding KV PEAK 170Ii.Lv Winding KV PEAK NA

    18 Efficiency At 75 C & Unity Power Factor

    A. At Full Load % 99.05

    B. At 3/4 Full Load % 99.22

    C. At 1/2 Full Load % 99.36

    19 Regulation At Full Load & 75C

    A. At Unity Power Factor % 1.10

    B. At 0.8 Power Factor Lagging % 5.07

    B. At 0.9 Power Factor Lagging % 3.41

    20 Terminal Arrangements

    A. Hv Side Cable box

    B. Lv Side Bus duct flange

    21 Approx. Weight

    A. Core & Winding Kg 4700

    B. Tank & Fittings Kg 3300

    C. Oil Kg 2000

    D.Total Mass Kg 10000

    C.Oil Ltrs. 2440

    Note:

    1. Efficiency and regulation values are calculated based on nominal values of NLL,LL & %Z.

    2. Weights and dimensions are subject to +/- 10% tol

    GUARANTEED TECHNICAL PARTICULARS

    ared by : PD Approved by : SP

    Page 1 of 1

    FORM NO.FM/TF/PMG/13