7
Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21 F-Frame Product Selection Table 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere Rating @40°C 100 125 150 175 200 225 240V AC Maximum, 125V DC (Includes Terminals on Load End Only) 65 kAIC @ 240V AC Type ED 2-Pole Catalog Number ED2100 ED2125 ED2150 ED2175 ED2200 ED2225 Price U.S. $ 357. 357. 357. 357. 357. 357. 3-Pole Catalog Number ED3100 ED3125 ED3150 ED3175 ED3200 ED3225 Price U.S. $ 885. 885. 885. 885. 885. 885. 1 00 kAIC @ 240V AC Type EDH 2-Pole Catalog Number EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 Price U.S. $ 850. 850. 850. 850. 850. 850. 3-Pole Catalog Number EDH3100 EDH3125 EDH3150 EDH3175 EDH3200 EDH3225 Price U.S. S 1,280. 1,280. 1,280. 1,280. 1,280. 1,280. 200 kAIC @ 240V AC Type EDC Current Limiting 2-Pole Catalog Number EDC2100 EDC2125 EDC2150 EDC2175 EDC2200 EDC2225 Price U.S. S 1,200. 1,200. 1,200. 1,200. 1,200. 1,200. 3-Pole Catalog Number EDC3100 EDC3125 EDC3150 EDC3175 EDC3200 EDC3225 Price U.S. S 1,655. 1,655. 1,655. 1,655. 1,655. 1,655. Note: Instruction Leaflet/FRED Number 29C101 Table 12-34. Type EHDThermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous @40°C 10© 15 20 25 30 35 - - 40 45 50 60 70 80 90 100 277V AC Maximum, 125V DC 14 kAIC @ 277V AC 480V AC Maximum, 250V DC 14 kAIC @ 480V AC Type EHD (Includes Terminals on Load End Only) 1-Pole Catalog Number EHD1010 EHD1015® EHD1020© EHD1025 EHD1030 EHD1035 EHD1040 EHD1045 EHD1050 EHD1060 EHD1070 EHD1080 EHD1090 EHD1100 Price U.S.S 123. 123. 123. 123. 123. 123. 123. 123. 123. 123. 238. 239. 238. 238. 2-Pole Catalog Number EHD2010 EHD2015 EHD2020 EHD2025 EHD2030 EHD2035 EHD2040 EHD2045 EHD2050 EHD2060 EHD2070 EHD2080 EHD2090 EHD2100 Price U.S.S 387. 387. 387. 387. 387. 387. 387. 387. 387. 387. 505. 505. 505. 505. 3-Pole Catalog Number EHD3010 EHD3015 EHD3020 EHD3025 EHD3030 EHD3035 EHD3040 EHD3045 EHD3050 EHD3060 EHD3070 EHD3080 EHD3090 EHD3100 Price U.S.S 498. 498. 498. 498. 498. 498. 498. 498. 498. 498. 600. 600. 600. 600. © Not UL listed. 5 kAIC interrupting rating. ® UL listed for SWD applications, see NEC Article 240-83 (d). Note: Instruction Leaflet/FRED Number 29C101 Discount Symbol. CB-2 CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T*N

Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

  • Upload
    others

  • View
    5

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

Cutler-HammerJanuary 2001Vol. 1, Ref. No. [04871

Molded Case Circuit Breakers10-225 Amperes 12-21

F-Frame

Product SelectionTable 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed

MaximumContinuousAmpereRating@40°C

100125150175200225

240V AC Maximum, 125V DC (Includes Terminals on Load End Only)

65 kAIC @ 240V ACType ED2-PoleCatalogNumber

ED2100ED2125ED2150ED2175ED2200ED2225

PriceU.S. $

357.357.357.357.357.357.

3-Pole

CatalogNumber

ED3100ED3125ED3150ED3175ED3200ED3225

PriceU.S. $

885.885.885.885.885.885.

1 00 kAIC @ 240V ACType EDH2-Pole

CatalogNumber

EDH2100EDH2125EDH2150EDH2175EDH2200EDH2225

PriceU.S. $

850.850.850.850.850.850.

3-Pole

CatalogNumber

EDH3100EDH3125EDH3150EDH3175EDH3200EDH3225

PriceU.S. S

1,280.1,280.1,280.1,280.1,280.1,280.

200 kAIC @ 240V ACType EDC Current Limiting2-PoleCatalogNumber

EDC2100EDC2125EDC2150EDC2175EDC2200EDC2225

PriceU.S. S

1,200.1,200.1,200.1,200.1,200.1,200.

3-PoleCatalogNumber

EDC3100EDC3125EDC3150EDC3175EDC3200EDC3225

PriceU.S. S

1,655.1,655.1,655.1,655.1,655.1,655.

Note: Instruction Leaflet/FRED Number 29C101

Table 12-34. Type EHD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

MaximumContinuous

@40°C

10©1520253035 - -40455060708090

100

277V AC Maximum, 125V DC14 kAIC @ 277V AC

480V AC Maximum, 250V DC14 kAIC @ 480V AC

Type EHD (Includes Terminals on Load End Only)1-Pole

CatalogNumber

EHD1010EHD1015®EHD1020©EHD1025EHD1030EHD1035EHD1040EHD1045EHD1050EHD1060EHD1070EHD1080EHD1090EHD1100

PriceU.S.S

123.123.123.123.123.123.123.123.123.123.238.239.238.238.

2-PoleCatalogNumber

EHD2010EHD2015EHD2020EHD2025EHD2030EHD2035EHD2040EHD2045EHD2050EHD2060EHD2070EHD2080EHD2090EHD2100

PriceU.S.S

387.387.387.387.387.387.387.387.387.387.505.505.505.505.

3-PoleCatalogNumber

EHD3010EHD3015EHD3020EHD3025EHD3030EHD3035EHD3040EHD3045EHD3050EHD3060EHD3070EHD3080EHD3090EHD3100

PriceU.S.S

498.498.498.498.498.498.498.498.498.498.600.600.600.600.

© Not UL listed. 5 kAIC interrupting rating.® UL listed for SWD applications, see NEC Article 240-83 (d).

Note: Instruction Leaflet/FRED Number 29C101

Discount Symbol. CB-2

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T*N

Page 2: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

12-2

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

January 2001

12

Product Line OverviewVol. 1, Ref. No. [0468]

Product Line DescriptionCutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as, “. . . a device for closing and inter-rupting a circuit between separable contacts under both normal and abnormal conditions,” and furthermore as, “. . . a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material.” The NEC describes them as, “A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating.”

So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and con-nected apparatus, such as motors and motor starters, against short circuits.

In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry.

This family of circuit breakers includes:

■ Thermal Magnetic Trip Breakers■ Electronic rms Trip Breakers■ Molded Case Switches■ Motor Circuit Protectors■ Current Limiting Breakers■ Special Application Breakers■ World Breakers

Special CalibrationSpecial non-UL-listed calibrations are available for certain ambient temperatures other than 40°C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 400 Hz applications. Maximum thermal calibration is limited to 135A at 400 Hz.

50°C CalibrationAdd suffix V to Catalog Number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50°C ambients.

Moisture-Fungus TreatmentAll circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment.

Freeze-Tested Circuit BreakersThe circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -40°C.

Marine ApplicationsF-Frame circuit breakers can be sup-plied to meet the following marine specifications:

■ U.S. Coast Guard CFR 46 ABS — American Bureau of Shipping IEEE 45

These specifications generally require molded case circuit breakers to be supplied with 50°C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied.

Circuit breakers can also be supplied to meet UL489 Supplement SA (Marine Use) and UL489 Supplement SB (Naval Use).

UL489 Supplement SA applies to vessels over 65 feet in length. Requirements include 40°C ambient calibration, spe-cial labeling, and no use of aluminum conductors or terminals.

UL 489 Supplement SB requires 50°C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals.

Standards and CertificationsMolded case circuit breakers are designed to conform with the follow-ing standards:

■ Underwriters Laboratories, Inc., Standard UL489, Molded Case Circuit Breakers and Circuit Breaker Enclosures

■ National Electrical Manufacturers Association Standards Publication No. AB1-1993, Molded Case Circuit Breakers

■ Australian Standard AS 2184, Molded Case Circuit Breakers

■ British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: Circuit Breakers

■ Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch Circuit Breakers

■ International Electrotechnical Commission Recommendations IEC 157-1, Circuit Breakers

■ Japanese T-Mark Standard Molded Case Circuit Breakers

■ South African Bureau of Standards, Standard SABS 156, Standard Specification for Molded Case Circuit Breakers

■ Swiss Electro-Technical Association Standard SEV 157-1, Safety Regula-tions for Circuit Breakers

■ Union Technique de l’Electricite Standard NF C 63-120, Low Voltage Switchgear and Control Gear Circuit Breaker Requirements

■ Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, Circuit Breakers

Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application.

Molded case circuit breakers equal or exceed Federal Specification Classifi-cation W-C-375b requirements for the particular class associated with the cir-cuit breaker frame being considered.

Note: For further information, see Circuit Breaker, CD-ROM SA.74A.01.T.E.

Suffix H01 400 Hz 20% Adder

Suffix J01 Fungus Treated $325. + 20% Adder

Suffix F01 Freeze Tested 20% Adder

Suffix H08 “Marine” 10% Adder

Suffix H09 “Naval” 10% Adder

Page 3: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

12January 2001 Product Line OverviewVol. 1, Ref. No. [0469]

Quick ReferenceTable 12-1. Industrial Circuit Breakers

� N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit.� Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250V DC.� Not defined in W-C-375b.

CircuitBreakerType

Cont.Amp.Rating@ 40°C

No.Poles

Volts Type of Trip �

Federal Spec.W-C-375b

UL Listed Interrupting Ratings rms Symmetrical Amperes PageNumberAC DC AC Ratings Volts DC �

120 120/240 240 277 480 600 125 250 125/250

G-FrameGBGB

15 – 10015 – 100

12, 3

120240

125125/250

N.I.T. 11a10b, 11b, 12b, 14b, 15b

65,000 —

——

—65,000

——

——

——

14,000—

——

—14,000

12-912-9

GHBGHBGHBGHBHGHBGQ

15 – 10015 – 10015 – 10015 – 10015 – 3015 – 20

12, 312, 311

120240277277/480277277

125125/250125125/250125—

N.I.T. 11a10b, 11b, 12b, 14b, 15b12c, 13a, 13b

65,000 ———65,00065,000

——————

—65,000————

——14,00014,000 25,00014,000

———14,000——

——————

14,000—14,000—14,000—

——————

—14,000 —14,000——

12-912-912-912-912-912-9

GHBSGBHS

15 – 3015 – 20

1, 21, 2

277/480347/600

——

—N.I.T.

——

65,000—

65,000—

——

14,000—

——

—10,000

——

——

——

11-1411-14

GCGC

15 – 10015 – 100

12, 3

120240

125125/250

N.I.T. 11a10b, 11b, 12b, 14b, 15b

65,000 —

——

—65,000

——

——

——

14,000—

——

—14,000

12-1112-11

GDGD

15 – 5015 – 100

23

480480

125/250250

N.I.T.N.I.T.

13b13b

——

——

65,00065,000

——

14,00022,000

——

——

—10,000

10,000—

12-812-8

GHCGHCGHCGHCHGHC

15 – 10015 – 10015 – 10015 – 10015 – 30

12, 312, 31

120240277277/480277

125125/250125125/250125

N.I.T. 12c, 13a13b12c, 13a13b

65,000 ———65,000

—————

—65,000———

——14,00014,000 25,000

———14,000—

—————

14,000—14,000—14,000

—————

—14,000—14,000—

12-1112-1112-1112-1112-11

New E125 FrameE125B 15 – 125 1

2, 3, 4277480

250 N.I.T. ——

35,000—

——

25,00025,000

18,000—

—18,000

——

10,000—

—10,000

——

12-16

E125E 15 – 125 2, 3, 4 600Y/347 250 N.I.T. — — — 35,000 — 25,000 18,000 10,000 10,000 — 12-16

E125S 15 – 125 12, 3, 4

347600Y/347

250 N.I.T.N.I.T.

——

100,000—

——

85,00085,000

35,000—

—35,000

—22,000

35,000—

—35,000

——

12-16

E125H 15 – 125 12, 3, 4

347600Y/347

250 N.I.T. ——

200,000—

——

100,000100,000

65,000—

—65,000

—25,000

42,000—

—42,000

——

12-17

F-FrameEDEDHEDC

100 – 225100 – 225100 – 225

2, 32, 32, 3

240240240

125125125

N.I.T. 12b14b1

———

———

65,000100,000200,000

———

———

———

10,00010,00010,000

———

———

12-2112-2112-21

EHDEHD

15 – 10015 – 100

12, 3

277480

125250

N.I.T. 13a13b

——

——

—18,000

14,000—

—14,000

——

10,000—

—10,000

——

12-2112-21

FDBFDB

15 – 15015 – 150

2, 34

600600

250250

N.I.T. 18a�

— —

——

18,00018,000

——

14,00014,000

14,00014,000

——

10,00010,000

——

12-2212-22

FDFDFD

15 – 22515 – 22515 – 225

12, 34

277600600

125250250

N.I.T. 13a22a�

— ——

— ——

—65,00065,000

25,000——

—25,00025,000

—18,00018,000

10,000——

—10,00010,000

— ——

12-2212-2212-22

HFDHFDHFD

15 – 22515 – 22515 – 225

12,3 4

277600600

125250250

N.I.T. 13a22a�

— ——

— ——

—100,000100,000

65,000——

—65,00065,000

—25,00025,000

10,000——

—22,00022,000

— ——

12-2212-2212-22

FDCFDC

15 – 22515 – 225

2, 3 4

600600

250250

N.I.T. 24a�

— —

— —

200,000200,000

— —

100,000100,000

35,00035,000

— —

22,00022,000

— —

12-2212-22

New J250 FrameJ250EJ250SJ250H

63 – 25063 – 25063 – 250

2, 3, 42, 3, 42, 3, 4

600600600

250250250

I.TI.TI.T

———

— ——

— ——

65,00085,000

100,000

———

25,00035,00065,000

18,00018,00025,000

———

10,00022,00022,000

— ——

12-2812-2812-28

Page 4: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

Cutler-HammerJanuary 2001Vol. 1, Ref. No. [0485]

Molded Case Circuit Breakers10-225 AmperesF-Frame

12-19

ContentsDescription

Product Description

Technical Dataand Specifications

Dimension/Weights

Product Selection ..

F-FramePage

12-19

12-1912-2012-20

Product Description• All F-Frame Circuit Breakers are

HACR rated.• All circuit breakers 10 through

50 amperes are suitable for HID(high intensity discharge) use.

• All F-Frame circuit breakers aresuitable for reverse feed use.

Typical F-Frame Breaker

Technical Data and SpecificationsTable 12-28. UL489 Interrupting Capacity RatingsCircuitBreakerType

EDEDHEDCEHD

FOBFD

HFD

FDC

Numberof Poles

2,32,32,312,32,3,412,3,412,3,42,3,4

Interrupting Capacity (Symmetrical Amperes) (kA)Volts AC (50/60 Hz)240

65100200

1818

65

100200

277

14

—25

65

480

1414

25

65100

600

_

14

18

2535

Volts DC &125

10101 01 0

—10

10

250 @®

1 010

1 0

2222

© DC ratings apply to substantially non-inductive circuits.® 2-pole circuit breaker, or two poles of 3-pole circuit breaker.® Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

Table 12-29. IEC 157-1 (PI) Interrupting Capacity Ratings (P1)

CircuitBreakerType

EDEDHEDCFOBFD

HFD

FDC

Number ofPoles

2,32,32,32,3,4

12,3,412,3,4

2,3,4

Interrupting Capacity (Symmetrical Amperes) (kA)Volts AC (50/60 Hz)220, 240

65100200

18

2565

65100

200

380,415

14

35

65

100

440

14

35

65

100

500

14

18

25

35

Volts DC A125

101010

—10

10

250 @®

10

10

22

22

® DC ratings apply to substantially non-inductive circuits.® 2-pole circuit breaker, or two poles of 3-pole circuit breaker.© Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T.N

Page 5: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

12-20 Molded Case Circuit Breakers10-225 AmperesF-Frame .. f-i -i

Cutler-HammerJanuary 2001

Vol. 1, Ref. No. [0486J

Dimensions/WeightsTable 12-30. Dimensions in Inches (mm)Numberof Poles

12

34

Width

1.375(35)2.75 (70)

4.125(105)5.5(140)

Height

6(152)6(152)

6(152)6(152)

Depth

3.375 (86)3.375 (86)

3.375 (86)3.375 (86)

Table 12-31. Approximate Shipping Weight, Lbs. (Kg)Breaker Type

ED, EDH, EDC

EHD, FOB, FD, HFD, FDC

Number of Poles1

—2 (.907)

2 3

3(1.361)

3(1.361)

4.5(2.041)

4.5(2.041)

4

6(2.721)

Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbersfor circuit breakers or trip units.

Table 12-32. Circuit Breaker Catalog Numbering System

FDC 3 100 L

Circuit BreakerType

EHDFOBFDHFDFDC

Numberof Poles

1 = 1 Pole2 = 2 Poles3 = 3 Poles4 = 4 Poles

Trip Ar

010015020025030035

J

0450500600700800901001 1 0125150175 (FD,200 (FD,225 (FD,

HFD, FDC, 2-, 3-, 4-Pole Only)HFD, FDC, 2-, 3-, 4-Pole Only)HFD, FDC, 2-, 3-, 4-Pole Only)

Circuit BreakerType

EDEDHEDC

Numberof Poles

2 = 2-Pole3 = 3-Pole

200

SuffixE = 100% Protected (4-Pole only) Neutral PoleEH = 50% Protected (4-Pole only)K = High Magnetic Molded Case SwitchL = Line and Load TerminalsS = Stainless Steel TerminalsV = 50°C CalibrationW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (< 100 Amperes)

SuffixL = Line and Load TerminalsW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (100 Amperes)

X

E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

Page 6: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

Cutler-HammerJanuary 2001Vol. 1, Ref. No. I0489]

Molded Case Circuit Breakers10-225 AmperesF-Frame

12-23

Molded Case SwitchesMolded Case Switches are used ascompact switches in applicationsrequiring high current switchingcapabilities. Molded case switchesare constructed of circuit breakercomponents and are of the highinstantaneous automatic type. Moldedcase switches are listed in accordancewith Underwriters Laboratories, Inc.,Standard UL 1087.

Line and Load TerminalsLine and Load Terminals provide wireconnecting capabilities for specificranges of continuous current ratingsand wire types. Except as noted,terminals comply with UnderwritersLaboratories, Inc., Standards UL486Aand UL486B. Unless otherwisespecified, F-Frame circuit breakersare factory equipped with loadterminals only.

Ordering InformationF-Frame circuit breakers and moldedcase switches have load terminalsonly as standard equipment. Whenstandard line-end terminals (same asstandard load-end terminals) arerequired, add Suffix L to the circuitbreaker Catalog Number. When non-standard or optional line and/or loadterminals are required, order by stylenumber. Specify if factory installationis required.

Table 12-37. Molded Case SwitchesMaximumContinuousAmpere Rating@40°C

480V AC Maximum,250V DCComplete Circuit Breakerwith Load Side Terminals OnlyCatalogNumber

PriceU.S. S

600V AC Maximum,250V DCComplete Circuit Breakerwith Load Side Terminals OnlyCatalogNumber

PriceU.S. $

2-Pole100150225

EHD2100K 476. FD2100KFD2150KFD2225K

535.001,135.001,135.00

3-Pole100150225

EHD3100K 570. FD3100KFD3150KFD3225K

665.001,240.001,190.00

4-Pole100150225 E —

FD4100KFD4150KFD4225K

930.001,735.001,665.00

Note: Molded Case Switches may open above 1800 amperes.Note: Instruction Leaflet/FRED Number 29C101

Table 12-38. Line and Load TerminalsMaximumBreakerAmperes

Terminal BodyMaterial

Wire Type AWG WireRange

Metric WireRange mm2

Package of 3 TerminalsCatalogNumber

PriceU.S. $

Standard Pressure Type Terminals20 (END)

100225

SteelSteelAluminum

Cu/AICu/AICu/AI

14-1014-1/014-4/0

2.5- 42.5- 50

25 - 95

3T20FB ©3T100FB3TA225FD

6.106.10

89.00Optional Pressure Terminals

50100200225

AluminumAluminumStainless SteelAluminum

Cu/AICu/AICuCu/AI

14-414-1/04-4/06 - 300 kcmil

2.5- 252.5- 50

25 - 9516 -150

3TA50FB ®3TA100FD3T150FB3TA225FDK i

6.106.106.10

89.00® Not for use with ED, EDH, EDC breakers.® Includes terminal shield kit. Adds approximately 3 inches (76.2) to breaker height. Available for

use on 3-pole breaker only.

Discount Symbol. CB-2

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog E:t>N

Page 7: Cutler-Hammer Molded Case Circuit Breakers 12-21 10-225 … · 2015-07-15 · Cutler-Hammer January 2001 Vol. 1, Ref. No. [04871 Molded Case Circuit Breakers 10-225 Amperes 12-21

Cutler-HammerJanuary 2001Vol. 1,Ref . No. [06431

Molded Case Circuit BreakersInternal AccessoriesUndervoltage Release Mechanism

12-177

Table 12-353. E125 Undervoltage Release MechanismElectrical RatingsVolts

122448-6048-60

1 1 0 - 1 2 71 1 0 - 1 2 5208 - 240220 - 250380 - 500525 - 600

Frequency Hz

50/60, DC50/60, DC50/60DC50/60DC50/60DC50/6050/60

CatalogNumber

UVR012CPKUVR024CPKUVR048APKUVR048DPKUVR120APKUVR125DPKUVR240APKUVR250DPKUVR480APKUVR600APK

PriceU.S.S

489.489.489.489.489.489.489.489.489.489.

Note: Instruction Leaflet/FRED Number 29C155

Table 12-354. F-Frame Factory Mounted (For F-Frame Breaker and F-Frame HMCP) Undervoltage Release MechanismVoltage Rating(AC Freq. = 50/60 Hz)

Connection Type and Location18-inch Pigtail LeadsSame SideSuffixNumber

AdderU.S.S

Rear &SuffixNumber

AdderU.S.S

Opposite SideSuffixNumber

AdderU.S.S

Terminal BlockSame SideSuffixNumber

AdderU.S.S

Left-Pole Mounting AC Ratings12V AC24V AC48V AC60V AC

110- 127V AC208 - 240V AC380 - 480V AC525 - 600V AC

U01U05U37U97U13U17U21U25

489.489.489.439.489.489.489.489.

U02U06U38U98U14U18U22U26

489.489.489.489.489.489.489.489.

U03U07U39U99U15U19U23U27

489.489.489.489.489.489.489.489.

U04U08U40U100U16U20U24U28

489.489.489.489.489.489.489.489.

Right-Pole Mounting AC Ratings 2i^12V AC24V AC48V AC60V AC

110 -127V AC208 - 240V AC380 -480V AC525 -600V AC

U49U53U85U101U61U65U69U73

489.489.489.489.489.489.489.489.

U50U54U86U102U62U66U70U74

489.489.489.489.489.489.489.489.

U51U55U87U103U63U67U71U75

489.489.489.489.489.489.489.489.

U52U56U88U104U64U68U72U76

489.489.489.489.489.489.489.489.

Left-Pole Mounting DC Ratings12V DC24V DC48V DC60V DC

110 -127V DC220 - 250V DC

U29U33U37U97U41U45

489.489.489.489.489.489.

U30U34U38U98U42U46

489.489.489.489.489.489.

U31U35U39U99U43U47

489.489.489.489.489.489.

U32U36U40U100U44U48

489.489.489.489.489.489.

Right-Pole Mounting DC Ratings (•.12V DC24V DC48V DC60V DC

110 -127V DC220 - 250V DC

U77U81U85U101U89U93

489.489.489.489.489.489.

U78U82U86U102U90U94

489.489.489.489.489.489.

U79U83U87U103U91U95

489.489.489.489.489.489.

U80U84U88U104U92U96

489.489.489.489.489.489.

® Standard pigtail lead exit location.© Standard mounting location.® Not for use on right pole of 4-pole circuit breaker.Note: Instruction Leaflet/FRED Number 29C160 and 29C179 (HMCP)Note: F-frame circuit breakers are factory sealed. Underwriters Laboratories, requires that internal accessories be installed at the factory.Internal accessories are UL listed for factory installation under E7819.Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation shouldbe done before the circuit breaker is mounted and connected.

Discount Symbol. CB-2

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F:T*N