4
CV20-60 Lister Petter Generating Set Technical Data Sheet ISO9001:2000 GENERATING SETS

CV20-60 Lister Petter Generating Set Technical Data Sheet

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CV20-60 Lister Petter Generating Set Technical Data Sheet

CV20-60 Lister Petter

Generating Set Technical Data Sheet

ISO9001:2000 GENERATING SETS

Page 2: CV20-60 Lister Petter Generating Set Technical Data Sheet

Powered by

Lister Petter Engines Generating Set

Page 2 of 4 Specifications may change without notice

SPECIFICATIONS

Standard Features

Lister Petter diesel engine and Stamford alternator

12V DC starting motor and storage battery

Brushless, Self-excited, IP23, insulation class H alternator

52°C radiator as standard

Key start panel control system

8-hour base tank

Open skid

All generating sets go through rigorous

load-bank testing, including 50% load, 75%

load, 100% load, 110% load, and all protective

functions (over-speed stop, high water

temperature, low oil pressure, battery charging

fail, emergency stop)

Genset Technical Data

3-Phase, 60Hz @ 1800 RPM, 208/120 Volts

Genset

Model

Genset Specification Engine Specification

Alternator

Model

kW Fuel

Cons

100%

(L/H)

dB(A)

@ 7m

Tank

(L) Model Cyl Gov Asp

Standby Prime

CV20-60 Lister 17 15.5 4.6 N/A 120 LPWS4 4 M NA PI044

Performance Information

Voltage Regulation

Voltage regulation maintained within ±0.5% as follow:

Power factor Between 0.8~1.0 lag

From no load to full load, any steady load

Speed droop variation under 5%

Frequency/Speed Variation

Change load from 0-100%, Frequency/Speed Droop Ratio within 5%

Page 3: CV20-60 Lister Petter Generating Set Technical Data Sheet

Powered by

Lister Petter Engines Generating Set

Page 3 of 4 Specifications may change without notice

Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Standards Compliance

ISO8528, GB/T2820

EN12601:2001, EN60034-22:1997, EN60204-1:2006

ISO9001:2000 Quality Control System

Dimensions and Weight

ENGINE SPECIFICATIONS

Lister-Petter Diesel Engine

Technical Data

Engine Model LPWS4

Emissions statement EPA tier 4

Number of Cylinders 4

Cylinder arrangement Vertical in-line

Cycle 4 stroke

Aspiration Natural Aspiration

Bore×Stroke (mm×mm) 86 x 80

Displacement (Liter) 1.86

Compression Ratio 18.5:1

Prime Power/Speed (kW/rpm) 18.6/1800

Standby Power/Speed (kW/rpm) 20.3/1800

Speed Governor Mechanical

Cooling System Water-cooled

Fuel Consumption at 100% Load (g/kWh) 210(at 1800RPM)

Starter Motor 12 V

Alternator 12 V

Open Skid

Overall size (L*W*H)

1400×500×900mm

Weight: 510kg

Page 4: CV20-60 Lister Petter Generating Set Technical Data Sheet

Powered by

Lister Petter Engines Generating Set

Page 4 of 4 Specifications may change without notice

ALTERNATOR SPECIFICATIONS

Stamford Alternator (Standard)

Technical Data

Alternator Model PI044

Exciter type Brushless, Self-excited

Power factor 0.8

Voltage Adjust range ≥5%

Voltage Regulation NL-FL ≤±1%

Insulation Grade H

Protection Grade IP23

Control System

DSE 702Key Start

Start/Stop controller

Ampere meter

Voltmeter and selector switch

Frequency meter / Water temperature gauge / Oil pressure

gauge / Hour counter / Battery voltage meter

Emergency stop pushbutton

Alarm System: Over speed, High Engine Temperature, Low Oil

Pressure, Charge Fail

Protection System: Over speed, High Engine Temperature,

Low Oil Pressure, Emergency Stop

4131 N. Central Expwy., Suite 200Dallas, Texas 75204Phone: 469.757.4271Fax: 469.757.4272