Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
DDD SSS RRRTTTDEEEES RTEEEEXTREMEXTREMEXTREMEXTREMEXTREMEXTREME
DDDDXXXXXX
Chill DownChill Down
Desert HeatDesert Heat
with DXKwith DXK
Chill Down
Desert Heat
with DXK
55°C
Imported
2016 Range
DESERT XTREME KOOLING (DXK)
*47%
NEW
DESERT XTREME KOOLING (DXK)
HEAVY DUTYAIRCONDITIONER
DESERT XTREME KOOLING (DXK)
R410AECO-FRIENDLY
DXK37CSS-S6
DXK50CS-S6
DXK53CSS-S6 / DXK74CSS-S6
*37%
NEW R410AECO-FRIENDLY
HYBRIDAIRCONDITIONER
+
HIGH CAPACITY MACHINES
HYBRID AC FOR ELECTRICITY SAVING UPTO 47%
We have designed the machines using higher capacity compressor + Bigger Condensor Unit for maximum, heat rejection for better cooling & higher energy efficiency, thereby we claim for Machine Capacities.
AMBIENT55 C
Super Tropical
HIGH CAPACITYMACHINE
ELECTRICITYSAVING UPTO
37%
COPPER
100%
HIGH CAPACITYMACHINE
Increase Your Comfort
LONG REACHAIR FLOW
SELF CLEANOPERATION
SELFDIAGNOSTIC
3D AIR
5 Star Rating
ELECTRICITYSAVING UPTO
47%
UPTO80 FEETLONGER
REFRIGERANTPIPE LENGTH
Upto 172 sq.ft.*
Upto 450 sq.ft.*
1.1 Ton
2.2 Ton
AREA COVERAGE MODEL NO. CAPACITY
DXK37CSS-S6
DXK74CSS-S6
DXK50CS-S6
DXK53CSS-S6 1.6 Ton
1.5 Ton Upto 225 sq.ft.*
Upto 280 sq.ft.*
SELF DIAGNOSIS FUNCTIONIn the case, when air conditioner malfunction, an internal Micro- Computer Automatically runs Self Diagnosis Function. The Self Diagnosis function displays the flashing lights on the indoor unit and the User is able to identify the problem by referring the user’s manual troubleshooting table and inform the problem.
SELFDIAGNOSTIC
HYBRID AC gives bigger area coverage1.5 timescompared to Conventional AC & still gives electricity savings upto 47%*
MAXIMUM COOLING CAPACITY MODEL NO.
DXK37CSS-S6
DXK74CSS-S6
DXK50CS-S6
DXK53CSS-S6
13500 BTU/hr.
19000 BTU/hr.
21000 BTU/hr.
26272 BTU/hr.
R410AECO-FRIENDLY
DESERT XTREME KOOLING (DXK)
HYBRIDAIRCONDITIONER
+
DXK53CSS-S6
Indoor Unit
Outdoor Unit
BEE Star Rating
SPECIFICATIONS
Unit
MODEL
5 STAR 5 STAR
+HYBRID - HEAVY DUTY AC (R410A)
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35 ºC. ** Under Standard Installation & Lab Test Condition*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be Air- conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specications without any prior notice
Compressor Type
Power Source
Maximum Cooling Capacity * Watts
BTU/h
BEE Rated Cooling Capacity W
BTU/h
Input Power ** ( Minimum ~ Maximum)
BEE Rated EER / COP
Current ( minimum ~ maximum ) **
Dimension (H x W x D) Outdoor Unit
Weight Outdoor Unit
Air Flow ( CMH )
Long Reach AirFlow Upto
Self Diagnosis Function
Sound Level (H/M/L)
Louver Swing
Special Filter
Blower Fan
DC Fan Motor Speed
Refrigerant
Refrigerant Injection in Coil
Refrigerant Piping Gas Line
Main Power Supply to
Connecting wiring
Area Coverage ***
Super Tropical - Return Cooled Rotary
Ton 1.6 2.2
6154 7700
21000 26272
Maximum EER / COP * W/w 5.04 4.28
Ton 1.6 2.0
5700 7625
19448 25248
watts 1220 ~ 1450 1800 ~ 2050
W/w 3.93 3.72
5.5 ~ 6.5 8.0 ~ 9.2A
Indoor Unit mm
mm 640 x 850 (+65) x 290 750 x 880 (+88) x 340
Indoor Unit Kgs 17 17
Kgs 44 57
Indoor Unit 1200 1400
Indoor Unit Feet 56 60
Indoor Unit Yes
Indoor Unit dB
Indoor Unit 3D + 3D AUTO
Indoor Unit
Indoor Unit Anti - Micro Bial
Indoor Unit
Indoor Unit 5 Point - Multi Port
mm
22.5 mm x 3 cores (including earthing cable ) 2 1.5 mm x 4 cores (including earthing cable ) B/w IDU & ODU
Sq.Feet 172 ~ 280 300 ~ 450
mm
Liquid Line
339 x 1197 x 262 339 x 1197 x 262
42 / 39 / 36 46 / 42 / 39
Enzyme + Photocatalytic Deodorizing Filter + Anti Bacterial
Auto/Powerful/High/Med/Low/Dry
3m /hr
Outdoor Unit
DXK53CSS-S6
DXC53CSS-S6
DXK74CSS-S6
DXK74CSS-S6
DXC74CSS-S6
DXK50CS-S6
3 STAR
45 / 43 / 41
2D
Anti Bacterial
Auto/Powerful/High/ Med/ Low
6.35 ( 1/4" )
15.88 ( 5/8" )
172 ~ 225
1 Phase, 220 / 230 V, 50 Hz
1.5
5569
19000
3.41
1.5
5280
18015
1400 ~ 1615
3.27
6.5 ~ 7.1
309 x 890 x 251
14
40
1050
40
640 x 850 (+65) x 290
Non Anti - Micro Bial
DXK50CS-S6
DXC50CS-S6
DXK37CSS-S6
5 STAR
1.12
3957
13500
3.96
1.1
3600
12283
700 ~ 1000
3.60
4.0 ~ 4.7
268 x 790 x 213
595 x 780 x 290
9.5
34
750
20
38 / 34 / 31
3D + 3D AUTOEnzyme+Solar+Anti-
Bacterial Filter
Anti - Micro Bial
4 Point - Multi Port
12.7 ( 1/2" )
2 1.5 mm x 3 cores (earthing cable )
129 ~ 172
DXK37CSS-S6
DXC37CSS-S6
ECO SMART- HEAVY DUTY AC (R410A)
AMBIENT55 C
Super Tropical
Sales & Service Offices in India:
JET AIR FLOW
Jet air flow technology gives long reachairflow upto 50 ft. for 1.5 times biggercoverage compared to conventional AC.
LONG REACH AIR FLOWIncrease Your Comfort
LONG REACHAIR FLOW
3D AIR3D AIR
3D AUTO
IAPL House, 2/8, West Patel Nagar Near Patel Nagar Metro Station- New Delhi- 110008 (INDIA) Tel.: 011-47230000-99, Toll Free No.: 1800 102 0055 Email: [email protected], Website: www.iaplgroup.com
1400 CMH
DXK53CSS-S6 (1.6 Ton) DXK74CKS-6 (2.2 Ton)
1200 CMH
R410A R410A
6.35 ( 1/4" )
15.88 ( 5/8" )
5 Point - Multi Port
Yes
AHMEDABAD: 9978991675, BANGALORE: 9035007043, BHOPAL: 9630033376, BHUBNESHWAR: 7381002850, BIHAR: 9334319838, CHENNAI: 8939991871, COCHIN: 9946936566, DEHRADUN: 9899143552, DELHI: 8826392381, DELHI NCR: 8800490704, HARYANA: 8929602345, HYDERABAD: 9885651712, INDORE: 9630033341, J&K: 9915009212, JAIPUR: 9983361035, KOLKATA: 8697744670, LUCKNOW: 9839054383, MUMBAI: 8879599905, NAGPUR: 9657004567, NASIK: 7769002430, NOIDA: 9899143552, PUNE: 8879599905, PUNJAB: 9915009212, RAJKOT: 9727731456, RAIPUR: 8879599905, JHARKHAND: 8697706530, SURAT: 9978996351, THRISSUR: 9946446067, VADODARA: 9978906175 .