Upload
mansour14
View
225
Download
0
Embed Size (px)
Citation preview
8/12/2019 d2u Integration and TRX CEM Capacity
1/12
All Rights Reserved Alcatel-Lucent 2008
BTS multistandard
d2U intgration
July 2009
8/12/2019 d2u Integration and TRX CEM Capacity
2/12
8/12/2019 d2u Integration and TRX CEM Capacity
3/12
All Rights Reserved Alcatel-Lucent 2009
Example:MBI 3 3 sectors 1 telecom subrack remove for d2U integration
Max Twin TRX 4Max xCEM Board 3
Max MC TRX 3Max xCEM Board 3 ?
To BE CHECK FOR POWER DISSIPATION
8/12/2019 d2u Integration and TRX CEM Capacity
4/12
All Rights Reserved Alcatel-Lucent 2009
Example:
MBI 5 3 sectors 1 telecom subrack remove for d2U integration
Max Twin TRX 8Max xCEM Board 3
Max MC TRX 6Max xCEM Board 3
To
BE CHECK FOR POWER DISSIPATION
8/12/2019 d2u Integration and TRX CEM Capacity
5/12
All Rights Reserved Alcatel-Lucent 2009
Example:
CIMA(G3 medi)- 3 sectors 1 telecom subrack remove for d2U integration
Max Twin TRX 8Max xCEM Board 3
Max MC TRX 6Max xCEM Board 3
To BE CHECK FOR POWER DISSIPATION
8/12/2019 d2u Integration and TRX CEM Capacity
6/12
All Rights Reserved Alcatel-Lucent 2009
Example:
CIDE(G4 medi)- 3 sectors 1 telecom subrack remove for d2U integration
Max Twin TRX 8Max xCEM Board 3
Max MC TRX 6Max xCEM Board 3
To BE CHECK FOR POWER DISSIPATION
8/12/2019 d2u Integration and TRX CEM Capacity
7/12
All Rights Reserved Alcatel-Lucent 2009
Example:COME (G3 medi outdoor) - 3 sectors depend of d2U configuration and thermal dissipation
Max Twin TRX 10Max xCEM Board 3
Max MC TRX 8Max xCEM Board 3
Max Twin TRX 12Max xCEM Board 3
Max MC TRX 9Max xCEM Board 3 ?
8/12/2019 d2u Integration and TRX CEM Capacity
8/12
All Rights Reserved Alcatel-Lucent 2009
Example:
CODE (G4 medi outdoor) - 3 sectors d2U integration in user space
Max Twin TRX 12Max xCEM Board 3
Max MC TRX 10Max xCEM Board 3
8/12/2019 d2u Integration and TRX CEM Capacity
9/12
8/12/2019 d2u Integration and TRX CEM Capacity
10/12
All Rights Reserved Alcatel-Lucent 2009
Example:
MBO1E - 3 sectors depend of d2U configuration and thermal dissipation
Max Twin TRX 6Max xCEM Board 3Max MC TRX 5Max xCEM Board 3
Max Twin TRX 3Max xCEM Board 3Max MC TRX 3Max xCEM Board 3
8/12/2019 d2u Integration and TRX CEM Capacity
11/12
All Rights Reserved Alcatel-Lucent 2009
Example:
MBO2 - 3 sectors depend of d2U configuration and thermal dissipation
Max Twin TRX 12Max xCEM Board 3Max MC TRX 10Max xCEM Board 3
Max Twin TRX 10Max xCEM Board 3Max MC TRX 9Max xCEM Board 3
8/12/2019 d2u Integration and TRX CEM Capacity
12/12
All Rights Reserved Alcatel-Lucent 2009
Example:
MBO2E - 3 sectors depend of d2U configuration and thermal dissipation
Max Twin TRX 12Max xCEM Board 3Max MC TRX 10Max xCEM Board 3
Max Twin TRX 12Max xCEM Board 3Max MC TRX 10Max xCEM Board 3