• The indoor unit is quiet in operation. The sound levels are as low as 44dB(A),comparable to refrigerator humming or a quiet conversation.
• You can select a high fan speed, providing you maximum reach.
• The indoor unit contains an air filter which removes microscopic particles and dust.
COMFORT
• Since the indoor unit has a low height it fits flush into a narrow ceiling void. Theinstallation of the unit only requires a false ceiling of only 360mm.
FLEXIBLE INSTALLATION AND MAINTENANCE
Air conditioner350 mm
Ordinary duct(Field supply)
Ordinary duct(Field supply)
Air blow Air intake360 mm or more
Concealed ceiling units are built into the false ceiling, leaving only the suction anddischarge grilles visible. Because the compact suction and discharge grilles can beplaced wherever you want, they are ideal for achieving uniform temperaturedistribution in large and heavily partitioned areas.Not only are concealed ceiling units visually the most unobtrusive, they are alsoamong the quietest type of air conditioning.
• The air discharge unit can beseparated from the actual airconditioner for use in long or largeareas by means of flexible ductsystems (ESP up to 250Pa). In thisway even very big areas can be keptcomfortable.
Long area
1
2
suction grille
discharge grille(field supply)of the flexible ducts
1
2
• Special anti-corrosion treatment ofthe outdoor unit’s heat exchanger fin,gives greater resistance against acidrain and salt corrosion. Additionalresistance is provided by a rust proofsteel sheet on the underside of the unit.
An anti-corrosion heatexchanger cutaway view
Aluminium
Hydrophilic film
Corrosion-resistantAcrylic resin
Heat exchanger
• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.
hayez_EPLE05-30B 19/01/06 10:54 Page 4
mov93585_EPLE05-30B
Cyan Magenta Yellow Black
COOLING ONLY - NON INVERTER(air cooled)
Cooling capacity nominal kWNominal input nominal kWEEREnergy labelAnnual energy consumption cooling kWhHEAT PUMP - NON INVERTER/INVERTER CONTROLLED(air cooled)
Cooling capacity nominal kWHeating capacity nominal kWNominal input cooling nominal kW
heating nominal kWEERCOPEnergy label cooling
heatingAnnual energy consumption cooling kWh
Notes:1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).
Capacity and power inputFDQ125B
RR125BW1
12.54.792.61
D2,395
FDQ125B FDQ125BV3 FDQ200BV3 FDQ250BV3RQ125BW1 RZQ125B8V3/BW1 RZQ200BW1 RZQ250BW1
12.5 12.5 20 2514.6 14 23 274.79 4.15 6.43 8.314.51 3.69 7.54 8.852.61 3.01 3.11 3.013.24 3.79 3.05 3.05
D B - -C A - -
2,395 2,075 - -
FDQ125B FDQ200B FDQ250B
350x1,400x662 450x1,400x90059 93 9343 69 8943 69 89
3 steps (direct drive) 2 steps (direct drive)44 45 4744 45 4775 81 82
ø9.52 ø12.7ø15.9 ø22.2
- ø25both liquid and gas pipes
COOLING ONLY/HEAT PUMP
Dimensions HxWxD mmWeight kgAir flow rate cooling M m3/min
heating M m3/minFan speedSound pressure level cooling H dB(A)
heating H dB(A)Sound power level cooling H dB(A)Piping connections liquid mm
gas mmdrain mm
Heat insulation
Specifications indoor units
FDQ125B FDQ200-250B
- Information is not available.
Indoor units : FDQ-B
hayez_EPLE05-30B 19/01/06 10:54 Page 5
mov93585_EPLE05-30B
Cyan Magenta Yellow Black
Dimensions HxWxD mmWeight kgCasing colourSound pressure level H dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBHEAT PUMP - NON INVERTER/INVERTER CONTROLLED
Dimensions HxWxD mmWeight kgCasing colourSound pressure level nominal dB(A)
Sound power level nominal dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB
heating from ~ to °CWB
1,170x900x320106
Ivory white5367
Hermatically scaled scroll typeR-410A
3.7070(equivalent length 90)
30-15~46
RQ125BW1 RZQ125B8V3/BW1 RZQ200BW1 RZQ250BW1
1,170x900x320 1,345x900x320 1,600x930x765108 106 225 226
Ivory white Ivory white53 (cooling) 50 (cooling - H) 57 57
45 (night quiet mode)67 (cooling) 66 (cooling - H) 78 78
Hermatically scaled scroll type Hermatically scaled scroll typeR-410A R-410A
3.7 4.3 8 970(equivalent length 90) 75 (equivalent length 95) 100 100
30 30 30 30-5~46 -15~50 -5~46-10~15 -20~15.5 -15~15
COOLING ONLY - NON INVERTER RR125BW1
Specifications outdoor units
KKPJ5F180 KKPJ5F180 - -- - KWC26B280
KHRQ22M20TA KHRQ22M20TAKHRQ127H KHRQ127H KHRQ250H
- KHRQ22M20TA (x3)
- KRP58M51 - -
Central drain plugCentral drain pan kitRefrigerant branch piping for twin
for triplefor double twin
Demand adapter kit remote control of soundreduction and power input
OUTDOOR UNITS RR/RQ125B RZQ125B RZQ200B RZQ250B
Accessories
Accessories: control systemsINDOOR UNITS FDQ125B FDQ200B FDQ250B
Wired remote control BRC1D52Central remote control DCS302C51Unified ON/OFF control DCS301B51Schedule timer DST301B51Remote ON/OFF, forced OFF EKRORO
AccessoriesINDOOR UNITS FDQ125B FDQ200B FDQ250B
Wiring adapter for electrical appendices KRP4A51Adapter for wiring (interlock for fresh air intake) KRP1B54Interface adapter for Sky Air series DTA112B51Option PCB for ext. electrical heater, humidifier and/or hour meter* EKRP1B2
Notes:1) V1 = 1~, 230V, 50Hz; V3 = 1~, 230V, 50Hz2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • equivalent refrigerant piping length 7.5m • level difference 0m.3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • equivalent refrigerant piping length 7.5m • level difference 0m.4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.5) The external static pressure is changeable: change the connectors inside the electrical box, this pressure means “high static pressure - standard - low static pressure”.6) The external static pressure is changeable: change the connectors inside the electrical box, this pressure means “high static pressure - standard”.7) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.8) The sound pressure level is measured via a microphone at a certain distance from the unit (for measuring conditions: please refer to the technical data books).9) The sound power level is an absolute value indicating the "power" which a sound source generated.
* Electrical heater, humidifier and hour meter are field supplied. These parts should not be installed inside the unit.
hayez_EPLE05-30B 19/01/06 10:54 Page 6
mov93585_EPLE05-30B
Cyan Magenta Yellow Black
Wired remotecontrol (Optional)
• Daikin remote controls give you easy control at your fingertips.
• The wired remote control provides you with a schedule timer, enabling the airconditioning to be programmed daily or weekly.
• The optional remote ON/OFF enables you to start/stop the air conditioning from amobile phone via a telephone remote control (field supply). The optional forced OFF enables you to switch off the unit automatically. E.g. when awindow is opened, the unit switches off.
ENERGY EFFICIENT
• This model can be used for cooling only or heating.
• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin, triple,double twin (connecting up to 4 indoors in the same room to a single outdoor).
When you go out push the“Home leave operation”button, and the airconditioner will adjustcapacity to reach thepreset temperature for“Home leave operation”.
When you return, youwill be welcomed bya comfortableair-conditioned room.
Push the “Home leaveoperation” button again,and the air conditionerwill adjust capacity tothe set temperature fornormal operation.
While out of the home
Improved comfort:The rapid start up time provided by the inverter increases comfort by reducing the leadtime in obtaining the required indoor temperature. As soon as the required temperatureis reached, the inverter unit continuously scans the room for small changes and adjuststhe room temperature in seconds, thereby increasing comfort once again.
• The ‘home leave’ operation button prevents large temperature differences bycontinuously operating at a minimum (heating mode) or maximum (cooling mode) presetlevel while you’re out or sleeping. It also allows the indoor temperature to return quicklyto your favourite comfort level.
ONE PUSH PUSH AGAIN
Inverter air conditioning
Non inverterair conditioning
Set point
Large temperaturedifference
Repeats hot and cold cycles
Keeps temperature stable
Startup time reducedby about 1/3
Slow start-upSmallertemperaturedifference
• Energy label: up to class A
• Inverter technologyImproved energy efficiency:The use of integrated inverter control ensures maximum energy efficiency by supplyingonly the required heating or cooling load where a standard non inverter unit would supplymaximum load in an on/off regime.
APPLICATION OPTIONS
hayez_EPLE05-30B 19/01/06 10:54 Page 1
mov93585_EPLE05-30B
Cyan Magenta Yellow Black
EPLE
05-3
0B /
1625
/ 01
/06
/ La
Mov
ida
Prin
ted
on n
on-c
hlor
inat
ed p
aper
/ Pr
inte
d in
Bel
gium
Daikin products are distributed by:
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikineurope.com
Daikin’s unique position as a manufacturerof air conditioning equipment, compressorsand refrigerants has led to its closeinvolvement in environmental issues. Forseveral years Daikin has had the intention tobecome a leader in the provision ofenvironmental friendly products. Thischallenge demands the eco design anddevelopment of a wide range of productsand an energy management system; whichinvolves energy conservation and reductionof waste.
“The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet tothe best of its knowledge. No express or implied warranty isgiven for the completeness, accuracy, reliability or fitness forparticular purpose of its content and the products and servicespresented therein. Specifications are subject to change withoutprior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arisingfrom or related to the use and/or interpretation of this leaflet.All content is copyrighted by Daikin Europe N.V..”
Daikin Europe N.V. is approved by LRQA for itsQuality Management System in accordance withthe ISO9001 standard.ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as toservices related to the product.
ISO14001 assures an effective environmentalmanagement system in order to help protect humanhealth and the environment from the potentialimpact of our activities, products and services andto assist in maintaining and improving the qualityof the environment.
Daikin units comply with the European regulationsthat guarantee the safety of the product.
Daikin Europe N.V. participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory.
hayez_EPLE05-30B 19/01/06 10:54 Page 2
mov93585_EPLE05-30B
Cyan Magenta Yellow Black