4
DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 CONTENTS 개요 ........................................ 2 표준사양 .................................. 2 압력손실 .................................. 2 표준크기 .................................. 3 형식기호 .................................. 4 설치방법 .................................. 4 FLOW STRAIGHTENER www.flotron.co.kr

Data Sheet (Flow Straightener) · 2020. 12. 31. · DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 표준크기 1. Flow Straightener mm inch A형 B형 25 1 300 225 40

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Data Sheet (Flow Straightener) · 2020. 12. 31. · DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 표준크기 1. Flow Straightener mm inch A형 B형 25 1 300 225 40

DATA SHEETUS Series KODS-US-01Flow Straightener Mar. 2009

CONTENTS

■ 개요 ............................................…2

■ 표준사양 ......................................…2

■ 압력손실 .....................................…2

■ 표준크기 ....................................…3

■ 형식기호 ......................................…4

■ 설치방법 ......................................…4

FLOW STRAIGHTENER

www.flotron.co.kr

Page 2: Data Sheet (Flow Straightener) · 2020. 12. 31. · DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 표준크기 1. Flow Straightener mm inch A형 B형 25 1 300 225 40

DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009

■ 개 요 유량계로 유입되는 전단부의 배관에서는 배관의 형상(Elbow, Reducer 등), 펌프의 종류에 따라 과대유량, 소용돌이,

유속의 불균형 등으로 유량계의 정밀 유량측정에 커다란 영향을 일으킬 수 있습니다.

정류관(Flow Straightener)은 이러한 현상을 방지하여 유량측정의 정밀도를 향상시키므로 Turbine Flowmeter,

Vortex Flowmeter, Mag Flowmeter 등의 유량계는 반드시 설치할 것을 권장합니다.

일반적으로 유입측의 직관부 길이를 15 ~ 50D로 (D : 배관의 직경) 권장하고 있으나, Flow Straightener를 설치할

경우 유량계 전단부의 길이는 9D 또는 12D로 줄일 수 있으며 또한 유속의 정류효과가 우수하므로 정밀측정에 큰

도움을 줍니다.

아울러 유량계 후단부에는 하류관(Downstream Pipe)을 표준길이 5D로 설치하여 사용할 것을 권장하고 있습니다.

■ 표준사양

Pipe Flange Inner Tube

US□□□D1 JIS 10K 14

US□□□D2 JIS 20K 28

US□□□D3 JIS 30K 51

US□□□D5 ANSI 150# 20

US□□□D6 ANSI 300# 52

US□□□ 1 JIS 10K 14

US□□□ 2 JIS 20K 34

US□□□ 3 JIS 30K 51

US□□□ 5 ANSI 150# 19.3

US□□□ 6 ANSI 300# 50.6

※ 1. 최고허용압력은 상온에서 각 플랜지 규격에 대한 값이며, 사양에 따라 차이가 있을 수 있습니다.

2. 재질기호는 사용조건에 따라 다를 수 있습니다.

3. Downstream Pipe에 대한 사양은 위 표와 동일합니다.

■ 압력손실 Flow Straightener를 통과한 유체의

압력손실 이론값은 다음과 같습니다.

(이때 압력손실 상수값 C는 우측의 그래프를

참조해 주십시요.)

ΔP : Pressure Loss (MPa)

C : 압력손실 상수

(Pressure Loss Coefficient)

ρ : 밀도 (Density, kg/m3)

www.flotron.co.kr 02

Sky Blue

(7.5 B4/4)

N/A

도장색

(Finish Color)

사용온도범위

(℃)

최고 허용압력

(kgf/cm2)

-10 ~ 300

SUS304

or

SUS316

A182-F304

or

A182-F316

A182-F304

or

A182-F316

A182-F304

or

A182-F316

SUS304

or

SUS316

SUS304

or

SUS316-196 ~ 300

형식기호 플랜지 구분재 질

ΔP = C · ρ · 10-5

STPG370 SS400 SUS304

A53-B(S)

or

A106-B(S)

A105 304SS

BCBCBCBCBC

1

0.5

0.2

0.1

0.02

0.05

압력

손실

상수

, C (액

체)

유 량 (m3/h)

25

10.01

2

5

10

2 5 10 20 50 100 200 500 1000 2000

40 50 80 100 150 200 2503001000

500

200

100

50

20

10

5

2

1

압력

손실

상수

, C (기

체.스

팀)

10 20 50 100 200 500 1000 2000 5000 10000 20000

← 액체

← 기체,스팀

배관크기 (mm) :

Page 3: Data Sheet (Flow Straightener) · 2020. 12. 31. · DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 표준크기 1. Flow Straightener mm inch A형 B형 25 1 300 225 40

DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009

■ 표준크기

1. Flow Straightener

mm inch A형 B형

25 1 300 225

40 1-1/2 480 360

50 2 600 450

80 3 960 720

100 4 1200 900

150 6 1800 1350

200 8 2400 1800

250 10 3000 2250

300 12 3600 2700

350 14 4200 3150

400 16 4800 3600

mm inch Boss 1 Boss 2 L A1 A2 B1 B2 B3 H

25 1 DS025□□ Ⅰ 1/2" NPT - 125 60 65 - - - 45

40 1-1/2 DS040□□ Ⅰ 1/2" NPT - 200 100 100 - - - 45

50 2 DS050□□ Ⅰ 1/2" NPT - 250 125 125 - - - 45

80 3 DS080□□ Ⅰ 1/2" NPT - 400 200 200 - - - 45

100 4 DS100□□ Ⅰ 1/2" NPT - 500 250 250 - - - 45

150 6 DS150□□ Ⅱ 1/2" NPT 3/4" NPT 750 - - 370 230 150 45

200 8 DS200□□ Ⅱ 1/2" NPT 3/4" NPT 1000 - - 500 300 200 45

250 10 DS250□□ Ⅱ 1/2" NPT 3/4" NPT 1250 - - 620 380 250 45

300 12 DS300□□ Ⅱ 1/2" NPT 3/4" NPT 1500 - - 750 450 300 45

350 14 DS350□□ Ⅱ 1/2" NPT 3/4" NPT 1750 - - 850 550 350 45

400 16 DS400□□ Ⅱ 1/2" NPT 3/4" NPT 2000 - - 1000 600 400 45

※ 1. 상기 표는 표준규격으로써 사양에 다를 수 있으며, 표준과 상이하게 할 경우에는 요구사양에 별도 명시해 주십시요.

2. 통상적으로 Boss 1은 압력계용, Boss 2는 온도계용으로 사용됩니다.

www.flotron.co.kr 03

US080□□□

US050□□□

US040□□□

치 수 (mm)

US100□□□

US300□□□

연결플랜지 크기

형태

2. Downstream Pipe

면간길이, L (mm)형식기호

US025□□□

US400□□□

Boss 크기연결플랜지 크기형식기호

US150□□□

US350□□□

US250□□□

US200□□□

L

Inner Tube

Boss 1

L

A1 A2

H

L

B1 B2 B3

Boss 1 Boss 2

< 형태 Ⅱ >< 형태 Ⅰ >

H

Page 4: Data Sheet (Flow Straightener) · 2020. 12. 31. · DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009 표준크기 1. Flow Straightener mm inch A형 B형 25 1 300 225 40

DATA SHEET US Series KODS-US-01 Flow Straightener Mar. 2009

■ 형식기호CODE FLOW STRAIGHTENER

US Flow straightener (Up-stream Pipe)

DS Downstream Pipe (하류관)

CODE FLANGE CONNECTION (배관크기)

025 25 mm (1")

040 40 mm (1-1/2")

050 50 mm (2")

080 80 mm (3")

100 100 mm (4")

150 150 mm (6")

200 200 mm (8")

250 250 mm (10")

300 300 mm (12")

350 350 mm (14")

400 400 mm (16")

□□□ 상기 이외의 경우

CODE MATERIAL

B Stainless Steel 304

C Stainless Steel 316

D Carbon Steel

O 상기 이외의 경우

CODE FLANGE RATING

1 JIS 10K RF

2 JIS 20K RF

3 JIS 30K RF

5 ANSI 150# RF

6 ANSI 300# RF

7 ANSI 600# RF

9 기타 Flange

CODE UP-STREAM TYPE (Flow Straightener에만 적용)

A Straightener (세관형, 12D) - 기본형

B Flow Conditioner (다공판형, 9D)

■ 설치방법

www.flotron.co.kr 04

A형:12D, B형:9D 5D

Flow Straightener Downstream Pipe유량계

(D : 배관크기)