Special Feature:
Fuse: Built-out
1.5 times rated power for 10s,2times for 2s(inverter)
Remote Control(Optional)
USB:5V,2.1A(Optional)
Protection: LED Indicator& Audible Alarm.
12V or 24V or 48VDC input
Input voltage range: -15% ~ +25%
Output voltage regulation: ±10%
3-Step Charger build in (Optional)
AC Auto-Transfer switch
Switchable UPS and ECO model
CE and RoHS Approved
Inverter with ups function
Congratulations and thank you for purchasing ours inverter ,Carefully read,
understand and comply with all instructions before use.
Ower’s ManualDC TO AC INVERTER
Appendix III:Battery Connect
In renewable energy systems, batteries are connected to each other in one of
three ways:
Series (voltage increases, amperage stays the same as a single battery)
Parallel (voltage stays the same as a single battery, amperage increases)
Series/Parallel (both voltage and amperage increase)
-17-
1. Important Safety Information............................................................
1.1 General Safety Precautions..............................................................
1.2 Precautions When Working With Batteries.........................................
2. General Information ...........................................................................
3. Application.........................................................................................
4.Electrial Performance.........................................................................
4.1 Inverter..........................................................................................
4.1.1 What is an Inverter?...............................................................
4.1.2 Pure Sine Wave Inverter..........................................................
4.1.3 Modified Sine Wave Inverter...................................................
4.1.4 Soft Start function.................................................................
4.2 AC Charger(Option)........................................................................
4.2.1 3-Step Charging....................................................................
4.3 UPS Mode and ECO mode...............................................................
5. Mechanical Drawing..........................................................................
5.1 Front Panel...................................................................................
5.2 Rear Panel....................................................................................
6. Protection Features:..........................................................................
6.1 Inverter Protection........................................................................
6.1.1 Modified sine wave inverter...................................................
6.1.2 Pure sine wave inverter..........................................................
6.2 AC charger protection(option)........................................................
7. Installation........................................................................................
7.1 Location.......................................................................................
7.2 DC Wire.......................................................................................
7.3 AC Wire.......................................................................................
7.4 Connections & Operations............................................................
8.Trouble Shooting Guide......................................................................
9. Specification.....................................................................................
9.1 Inverter with AC Auto Switch........................................................
9.2 Inverter with AC Auto Switch and Charger Function.......................
10.Warranty ........................................................................................
1
1
1
2
2
3
3
3
3
3
3
3
3
4
4
4
6
6
6
7
8
8
8
8
8
9
9
11
13
15
6
11
Appendix II: DC Wire
For correct operation, the battery voltage should be between 0.9xVnom and 1.29x
Vnom where Vnom is 12V, 24V or 48V depending on model, and must be able to
supply sufficient current to your inverter. The following table displays the
recommended things(battery cable, Fuse, Battery Capacity) per inverter type :
-16-
1.2 Precautions When Working With Batteries
1.2.1 If battery acid contacts skin or clothing, wash immediately with soap and
water. If acid enters eyes, immediately flood eye with running cold water
and get medical attention immediately.
1.2.2 Never smoke or allow a spark or flame in the vicinity of a battery or engine.1.2.3 Do not drop a metal tool on the battery. The resulting spark or short-circuit
on the battery may cause an explosion.
1.2.4 Remove personal metal items such as rings, bracelets, necklaces, and
CAUTION: Equipment Damage The output side of the inverter's AC wiring should at no time be connected
to public power or a generator. This condition is far worse than a short circuit.
If the unit survives this condition, it will shut down until corrections are made.
Installation should ensure that the inverter's AC output is at no time be connected
to its AC input.
-1-
1.1 General Safety Precautions
1.1.1 Do not expose the Inverter to rain, snow, spray, bilge or dust. To reduce
risk of hazard, do not cover or obstruct the ventilation openings. Do not
install the Inverter in a zero-clearance compartment,Overheating may
result. Allow at least 30CM of clearance around the inverter for air flow.
Make sure that the air can circulate freely around the unit. A minimum air
flow of 145CFM is required.
1.1.2 To avoid risk of fire and electronic shock, make sure that existing wiring
is in good electrical condition and that the wire is not undersized. Do not
operate the Inverter with damaged or substandard wiring.
1.1.3 This equipment contains components which may produce arcs or
sparks. To prevent f ire or explosion do not install in compartments
containing batteries or flammable materials or in a location which require
igni t ion protected equipment. This includes any space containing
gasoline-powered machinery, fuel tanks, or joints, fittings, or other
connection between components of the fuel system.
1.1.4 Do not disassemble the Inverter. It contains no user-serviceable
parts. Attempting to service the Inverter yourself may result in
electrical shock or fire. Internal capacitors remain charged after all power
is disconnected.
1.1.5 To reduce the risk of electrical shock, disconnect both AC and DC power
from the Inverter,before attempting any maintenance or cleaning.
Turning off controls will not reduce this risk
1. Important Safety Information
20A 3
35A 4
20A 4
35A
20A
5
5
25A
20A
6
6
35A 8
20A 8
35A
20A
20A
20A
10
10
10
10
10. Warranty
We warrant this product against defects in initial PCB, components and any
manufacturing defects for one full year from date of purchase and will repair
or replace any defective inverter. This warranty is issued only at the time of
original purchase; it is non-transferable. Damage caused by accident, misuse,
do-it-yourself repairs, sand, oil or water is not covered by this warranty. This
is only warranty and the company makes no other warranties, express or
implied, including warranties of merchant ability and fitness for a particular
purpose.Appendix I
Remote Control Switch
Power ON/OFF Switch
Power ON/OFF switch is to turn the inverter on or off.
Battery Capacity/Load Voltage indicator
Load: Show the approximate connected equipment load level.
Four Levels---25%,50%,75%,100%.
Battery: Show the battery residual capacity.
Four Levels---25%,50%,75%,100%.
AC In Indicator
AC In: after correct connect the AC mains , the light will turn on.
Bypass: under Bypass function,the light will on .
Charge In:Under charge function ,the light will on
Fault: Turns red show fault, refer to Troubleshooting of Inverter Manual.
Connecting the Communications Cable
The communications cable is 3meters, 6-conductor cable (wired like a normal
telephone-type cable). This cable is connected to the RJ11 jack on the rear of
the remote control and to the REMOTE port located on the rear of the inverter.
ONOFF
BYPASS
INVERTER
ACCHARGE
AC IN
LOADBATTERY
100%
25%
Model No KS-03
50%
75%
ONOFF
BYPASS
INVERTER
AC IN
LOADBATTERY
100%
25%
Model No KS-02
50%
75%
Inverter Remote Controller
Green : Power OnFlash : Fault
-15-
Notice:
Inverter's ON/OFF Switch and Remote control's ON/OFF Switch is in parallel.
To use this remote control, must turn the inverter's ON/OFF Switch to OFF,and
vice versa.
watches when working with a lead-acid battery. A lead-acid battery
produces a short-circuit current high enough to weld a ring or the like to
metal, causing a severe burn.
1.2.5 To reduce the risk of injury, charge only deep-cycle lead acid, lead
antimony, lead calcium gel cell , absorbed mat, or NiCad/NiFe type
rechargeable ba t te r ies . Other types of batteries may burst , causing personal injury and damage.
1.2.6 Sparks may result during final battery connection.Always observe proper polarity as batteries are connected
2 General Information .
I nverter with UPS function is a combination of an inverter,AC Auto-
transfer switch and battery charger (Option) into one complete system with a peak dc to ac conversion efficiency of 90%. It is packed with unique features
and it is one of the most advanced system in the market today. There are two model to your choose.
UPS model:it also called the AC priority .the AC power will be direct to
the loads through bypass ways. if have charger build in, AC power also will be
used to charge the battery ;
ECO model : it also called the Battery Priority . the inverter will always
prefer to inverter electricity from battery first even there is a qualified AC
input present .only when the battery voltage reaches the low voltage point.
(11Vdc for 12V battery ,22V dc for 24V battery ,44V dc for 48V battery ), the
inverter transfer to AC input to charge the battery, and switch back to battery
when the battery voltage from (13Vdc for 12V battery,26V dc for 24V battery,
52V dc for 48V battery ),
3. Application
Power tools–circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors.
Office equipment – computers, printers, monitors, facsimile machines,
Household items – vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines.
Kitchen appliances – coffee makers, blenders, ice markers, toasters.
Industrial equipment – metal halide lamp, high – pressure sodium lamp.
Home entertainment electronics – television, VCRs, video games, stereos, musical instruments, satellite equipment.
Note: When under the AC bypass function , if have charger build in , the
charger will charge the battery.
-2-
100%
25%
50%
75%
Inverter Remote Controller
100%
25%
50%
75%
Green : Power OnFlash : Fault
Model Item
KSC300M KSC500M KSC1000M KSC1500M KSC2000M
Rated Power 300W 500W 1000W 1500W 2000W
Surge Power 120%<Load<150% Rated power for 10s,150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% Inverter AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Modified Sine Wave at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. DC Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
Model Item
KSC2500M KSC3000M KSC4000M KSC5000M KSC6000M
Rated Power 2500W 3000W 4000W 5000W 6000W
Surge Power 120%<Load<150% Rated power for 10s
150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Modified Sine Wave at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
AC Out Receptacle USA, UK, Germany, France, Australia, Brazil, Italy, South Africa, etc.
Cooling Temperature and Load Controlled
Operating
Temperature
-5°C to 40°C
Storage Temperature -5°C to 85°C Environment
Relative Humidity 20% ~ 90% RH non-condensing
-14-
Modified Sine Wave Inverter with AC Auto Switch and Charger
4. Electrical Performance
4.1. Inverter
4.1.1 What is an Inverter?
Power inverter is an electronic device that convert DC(Direct Current) battery power to standard AC(Alternating Current) power. DC is the power that is produced by battery while AC is the standard power needed to run
electrical equipment. A power inverter does the opposite of a rectifier and is
used in places and situations where AC power is not available.
4.1.2 Pure Sine Wave Inverter
If you want to run your equipment exactly to the manufacturer's specifications,
choose a pure sine wave inverter. With pure sine wave, motor loads start easier
and run cooler. Some equipment only operate properly with pure sine wave
inverter, such as laser printers, variable speed motors and digital clocks.
4.1.3 Modified Sine Wave Inverter
If your equipment can accept some voltage fluctuation , consider a modified sine wave inverter . These inverters provide mobile power at a more affordable
price and come in a full range of size from handheld to high performance . Do
not use to power sensitive devices such as medical equipment or computers .
Some audio equipment may perform poorly if run on Modified Sine Wave power Inverter
4.1.4 Soft Start function our inverter is engineer with Soft Start features , when the inverter is turning
on , the output voltage gradually ramp up from 0VAC to Rated Voltage in about
1 Sec, this effectively reduce high starting inrush current drawn by AC loads
such as switched mode power supplies and inductive loads .
Do not parallel the AC output of the inverters to increase CAUTION:power capacity as they have no stacking functionality.
4.2 AC Charger(Option)
4.2.1 3-Step ChargingA) Bulk Charge Stage: Current is supplied to the battery at a constant rate while
PURE SINE WAVE(PSW) MODIFIED SINE WAVE (MSW)
-3-
This AC battery charger is high efficiency charger that will fully charge and maintain a battery at it’s proper storage voltage without the damaging effects cased by trickle chargers .it is and ideal charger for everyday charging use or long term storage and maintenance .
9.2 Inverter with AC Auto Switch and Charger Function
Model Item
KSC300P KSC500P KSC1000P KSC1500P KSC2000P
Rated Power 300W 500W 1000W 1500W 2000W
Surge Power 120%<Load<150% Rated power for 10s,150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% Inverter AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Pure Sine Wave(THD<4%) at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. DC Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
Model Item
KSC2500P KSC3000P KSC4000P KSC5000P KSC6000P
Rated Power 2500W 3000W 4000W 5000W 6000W
Surge Power 120%<Load<150% Rated power for 10s
150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Pure Sine Wave(THD<4%) at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
AC Out Receptacle USA, UK, Germany, France, Australia, Brazil, Italy, South Africa, etc.
Cooling Temperature and Load Controlled
Operating
Temperature
-5°C to 40°C
Storage Temperature -5°C to 85°C Environment
Relative Humidity 20% ~ 90% RH non-condensing
-13-
Pure Sine Wave Inverter with AC Auto Switch and Charger
voltage gradually rises.
B) Absorption Charge: Voltage remains constant and current reduces as the
battery becomes charged. This ensures complete charging.
C) Floating Stage: After the battery reach full charge, charging voltage is
reduced to a lower level to prevent gassing and to prolong life. This stage is
often referred to as a maintenance charge. Rather than charging a battery, it
keeps an already-charged battery from discharging while providing load current.
Absorb Charging: 14.6 Vdc(12V version)/
29.2Vdc(24V version)
Float Charging: 13.8Vdc(12V version)/
27.6Vdc(24V version)
*Charging voltages can be customized
in factory.
4.3 UPS Mode and ECO mode
4.3.1 UPS Mode : the AC input of the inver ter is cont inual ly moni tored.
Whenever AC power falls ,the inverter automatically transfers back to
the inverter mode with minimum power interruption to your appliances-
as long as the inverter is turned on. The transfer time is usually fast enough
to keep your equipment (including computers) powered up. The time will
be less than 16 milliseconds .4.3.2 ECO Mode : Battery voltage is lower than alarm point , the inverter
automatically transfers back to the AC utility to the loads, the transfer
time also very fast enough to keep your equipment(including computers)
powered up . The time will be less than 16 milliseconds. After low battery
voltage shut off, the inverter is able to restore to work after the battery
voltage recovers to 13V/26V/52V(With power switch still in “ON” Position).
5. Mechanical Drawing
5.1 Front Panel
Time
Ich
arg
eV
ch
arg
e
Bulk Absorption Float
FUSE
ON
OFF
UPS Mode
ECO Mode
2.1
A/5
V
Inverter Fault
AC-IN By- Pass
AC Charger
AC Output
AC Input
GND
Remote
-4-
With charger type
Model Item
KS300MT KS500MT KS1000MT KS1500MT KS2000MT
Rated Power 300W 500W 1000W 1500W 2000W
Surge Power 120%<Load<150% Rated power for 10s,150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% Inverter AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Waveform Modified Sine Wave at rated input voltage
O
U
T
P
U
T Protection AC short circuit, Overload, Over temperature
Bat. DC Voltage 12V/24V/48V
AC Voltage 90-120V/180-240V
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T
Battery Types Open & sealed lead acid battery
Model Item
KS2500MT KS3000MT KS4000MT KS5000MT KS6000MT
Rated Power 2500W 3000W 4000W 5000W 6000W
Surge Power 120%<Load<150% Rated power for 10s 150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Modified Sine Wave at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
AC Out Receptacle USA, UK, Germany, France, Australia, Brazil, Italy, South Africa, etc.
Cooling Temperature and Load Controlled
Operating
Temperature
-5°C to 40°C
Storage Temperature -5°C to 85°C Environment
Relative Humidity 20% ~ 90% RH non-condensing
-12-
Modified Sine Wave Inverter with AC Auto Switch
A) ON/OFF Switch: this switch controls ON/OFF operation of the unit
B) AC Input: plug AC input cable into it and AC source
C) AC Outlet: For application demands of different geographic areas all over the world, there are many different kinds of optional AC receptacle to choose from.
AC Input Terminal Block: a screw type terminal block for attaching AC output wires. Each slot is labeled L for Lines and N for Neutral. Connect the incoming Line wire to the input L slot, Connect the incoming Neutral wire to the input N slot.
AC Output Terminal Block: a screw type terminal block for attaching AC
output wires. Each slot is labeled L for Lines and N for Neutral. Connect the outgoing Line wire to the output L slot, Connect the outgoing Neutral wire to
the output N slot.
D) Hardwire Terminal Block: when the load current is >15A, must use Hardwire terminal connection.
E) Fuse breaker: under “bypass mode”, when the AC output is shorted or the
load current exceeds the rated current of the fuse breaker, the fuse breaker
will be burned to stop bypassing energy from the utility getting to present possible danger.
F) Ventilation holes: the inverter requires suitable ventilation to work properly. Please make sure there is good ventilation and the lifespan of the inverter can be preserved.
-5-
FUSE
ON
OFF
UPS Mode
ECO Mode
2.1
A/5
V
Inverter Fault
AC-IN By- Pass
AC Output
AC Input
GND
Remote
Without charger type
AC OUTPUT AC INPUTOpen this cover before connecting
9. Specification
9.1 Inverter with AC Auto Switch
Model Item
KS300PT KS500PT KS1000PT KS1500PT KS2000PT
Rated Power 300W 500W 1000W 1500W 2000W
Surge Power 120%<Load<150% Rated power for 10s,150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% Inverter AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Waveform Pure Sine Wave(THD<4%) at rated input voltage
O
U
T
P
U
T Protection AC short circuit, Overload, Over temperature
Bat. DC Voltage 12V/24V/48V
AC Voltage 90-120V/180-240V
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T
Battery Types Open & sealed lead acid battery
Model Item
KS2500PT KS3000PT KS4000PT KS5000PT KS6000PT
Rated Power 2500W 3000W 4000W 5000W 6000W
Surge Power 120%<Load<150% Rated power for 10s 150%<Load<200% Rated power for 2s
100V/110V/115V/120Vac or 220V/230V/240Vac
AC output regulation: 10% AC Voltage
Frequency:50Hz±1%,60Hz±1%,50/60Hz(Optional),switch by manual
Charger DC Voltage 12V/24V/48V
Waveform Pure Sine Wave(THD<4%) at rated input voltage
O
U
T
P
U
T
Protection AC short circuit, Overload, Over temperature
Bat. Voltage 12V/24V/48V
Charger AC Voltage 90-120V/180-240V
Efficiency More than 85%
Protection Battery Low Alarm, Battery Low Shutdown, Battery Polarity Reverse by Fuse
I
N
P
U
T Battery Types Open & sealed lead acid battery
AC Out Receptacle USA, UK, Germany, France, Australia, Brazil, Italy, South Africa, etc.
Cooling Temperature and Load Controlled
Operating
Temperature
-5°C to 40°C
Storage Temperature -5°C to 85°C Environment
Relative Humidity 20% ~ 90% RH non-condensing
-11-
Pure Sine Wave Inverter with AC Auto Switch
G) Frame ground(FG):connect a copper wire between the grounding terminal
on the inverter and earth grounding system or vehicle chassis.
H) Communication port: for remote control purpose,the unit can be connected
a remote control panel by using the optional cable
I) UPS and ECO mode switch: Automatic mains priority circuit
A) DC Battery Terminals: Connect the inverter to battery or other power sources.
Negative (-) and Positive (+) DC terminals should be kept insulated to protect
from accidental short circuits.
B) Fuse: Fuse was built-out is a very good design as you can very easy to change the fuse outside the inverter if your inverter fuse was blown.
C) Fan Operation:
Load and temperature multiple control the cooling fan .when loads over 20% rate power or inner temperature is over 45 ºC
6.1 INVERTER PROTECTION
5.2.Rear Panel
J) Led indication: Operating status, warning
Inverter: The inverter started up and output is normal.
Fault: Warning user there is some problem,need to check the system now. Such as low voltage,over voltage,over load,short circuit and so on. AC in: The status of utility is normal.
Bypass: The unit is working under “bypass mode”, the AC electricity consumed by the loads is provided by the utility instead of the inverter.
AC charger: The built-in AC charger is charging external batteries.
F U S
F U S
F U S
F U S
F U S
F U S
F U S
F U S
F U S
-6-
6. Protection Features:
6.1.1 Modified sine wave inverter
A)Input Low Voltage Protection
When battery voltage is below 10.5V±0.5V(12V version)/21V±1.0V(24V
version)/ 42V±2.0V(48V version), a buzzer will alarm and fault light turn on
Notice: M—Modified sine wave inverter P---Pure sine wave inverter -10-
need to recharge.
When input voltage is below 10V±0.5V(12V version)/20V±1.0V(24V
version)/ 40V±2.0V(48V 12V version), AC output will be automatically shut off, a buzzer alarm and fault light turn red.
B) Input Over Voltage Protection
When input voltage reach 16V±0.5V (12V version)/32V±1.0V (12V version)/
64V±2.0V (48V version), the fault light turn red and the AC output will be shut
off automatically.
C) Short Circuit Protection
When short circuits occur, fault light turn red, output will be shut off.
D) Overload ProtectionWhen overloads occur, fault light turn red, output will be shut off.
E) Reverse polarity protection
When battery terminals are reverse connected, fuse will be burned to protect appliances.
F) Over Temperature Protection
When heat sink temperature exceeds 45ºC, the inner cooling fan will automatically
turn on to cool the inverter,When inner temperature exceeds 75ºC, AC output will
automatically shut off.
6.1.2 Pure sine wave inverter
A) Input Low Voltage Protection:
When battery voltage is below 10.5V±0.5V(12V version)/21V±1V(24V
version)/ 42V±2V(48V version), Buzzer sound 2times, which indicates
DC power supply voltage is descending and batteries need to recharge.
When input voltage is below 10V±0.5V(12V version)/20V±14V(24V
version)/ 40V±2V(48V version), Buzzer sound 3 times and red light turn
on , AC output will be automatically shut off.
B) Input Over Voltage Protection
When input voltage reach 16V±0.5V (12V version)/32V±1V (24V version)/
64V±2V (48V version), Buzzer sound 4times and red light turn on, the AC
output will be shut off automatically.
C) Short Circuit Protection
When short circuits occur, buzzer sounds 11 times and red light turn on, output
will be shut off.
-7-
red which indicates DC power supply voltage is descending and batteries
6
2
4
6 2 4
6
2 4
Red light turn on--M
Buzzer sound many times andred light turn on --P
red light turn on --P
qualified electrician about the specific wire gauge required in term of wire material and inverter power .
7.4 Connections & OperationsStep 1 Connect the (+) and (-) cables from the battery to the respective terminals of the unit.Step 2 Plus in the AC source to real panel AC Input Socket(Hard Block Terminal)
Step 3 Connect the earth cable from the AC ground system to that of the unit
Step4 To start the unit, turn on the ON/OFF switch. LED green lights on, Charger and AC power on.Step5 Connect consumer unit to the socket in the front of the unit
Step 6 Make sure the cable is firmly connected in the socket. If the connection is not firm enough, the plug will heat up and cause unit damage
Step 7 USB only supply output power source
Warning: The output voltage of this unit must never be connected in it's input
AC terminal, overload or damage may result.Always switch on the inverter
before plugging in any appliance. Damage caused by AC wiring mistakes are
not covered under warranty .
8. Trouble shooting GuideTrouble shooting contains information about how to trouble shoot possible
error conditions while using the InvertersThe following chart is designed to help you quickly pinpoint the most common inverter failures.
-9-
6.2 AC charger protection(option)
A) Over charging protection B) Short circuit protectionC) Over Temperature protectionD) Reverse Polarity Portection .
7 INSTALLATION
Please instal l the equipment in a location of Dry, Clean, Cool with good ventilation.
Working temperature: -5℃ to 40℃ Storage temperature: -5℃ to 70℃ Relative Humidity: 0% to 95%_non-condensing
Cooling: Forced air
7.2 DC WireThough your Inverter is a high-efficiency converter of electricity, its rated
output capacity is limited by the length and gauge of the cabling running from
the battery to the unit. Use the shortest length and largest diameter cabling to
fit your Inverter's DC Input terminals. Shorter and heavier gauge cabling
reduces DC voltage drop and allows for maximum transfer of current. Your
Inverters is capable of delivering peak wattage at up to 200% of its rated
continuous wattage output for brief periods of time. Heavier gauge cabling
should be used when continuously operating heavy draw equipment under
these conditions. Tighten your Inverters and battery terminals to approximately
0.8 Meter to create an efficient connection and to prevent excessive heating at
this connection. Insufficient tightening of the terminals could void your
warranty.
7.3 AC Wire when in bypass mode the AC input power will supply both the loads and
AC charger, a thicker wire gauge for AC input is required,please consult a
Via MOSfet(Optional): When battery terminals are reverse connected, the
inverter won't work unit correct connect.F) Over Temperature Protection
When hea t s ink t empera tu re exceeds 45 ºC , the inner coo l ing fan wi l l
automatically turn on to cool the inverter; When inner temperature exceeds
75ºC, AC output will automatically shut off, Buzzer sound 5 times and red
light turn on.
D) Overload ProtectionWhen overloads occur, buzzer sounds many times and red light turn on, output
will be shut off.E) Reverse polarity protection: Fuse or MOSfet
Via Fuse: When battery terminals are reverse connected, fuse will be burned
to protect appliances.
-8-
7.1 Location.
Low battery