LWS - LHB LED High Bay Description Performance Data Input Voltage: 120-277V Lens: No lens (standard). An opaque diffused acrylic lens is available for applications where glare reduction is needed. Mounting: Fixture mounting options include: Pendant, Surface Mount Brackets, Toggle & Cable, Safety Hook / No Cord, and Safety Hook with 6’ Cord. NEMA Plug: Plug offerings are compliant to the standards set forth by the US National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. Color Temperature: 4000K NW (standard), 5000K CW. LED Lifetime: All LED’s are rated for a minimum of 100,000 hours of continuous operation at ambient temperatures from -40°F/-40°C to 104°F/40°C. Color Rendering Index (CRI): Minimum of 70 or higher. Dimming: 0-10V standard dimming capability. Surge Protection: Thermally protected 20kA/ 40kV varistor type surge suppressor is included and meets ANSI C136.2-2015: Extreme Level. Also meets IEC61643-11 Class II / EN61643-11 Type 2, and US Dept of Energy MSSLC Model Spec for surge protection. The device is wired in series with the luminaire input power in order to interrupt power to the luminaire when consumed, protecting the LED power supply and circuit boards from additional electrical surges. Lumecon ETD™ System: The enhanced thermal dissipation system engines are thermally bonded to provide maximum thermal dissipation to the exterior of the fixture to ensure long life. To protect the light engine panel from moisture and corrosion, the LED light engine panel is uniformly coated with a UV stabilized acrylic polymer resin that meets MIL and ASTM dielectric standards, UL, and IPC standards for flammability, moisture resistance and thermal shock. DesignLights Consortium ® (DLC) Qualified Product: The 4000K NW and 5000K CW are DLC ® Qualified. Unless noted, not all versions of this product may be DLC ® qualified. For a complete list of Lumecon DLC ® Qualified Products visit: www. designlights.org. Certification Data: ETL Listed to UL 1598, UL 8750 and CSA 22.2 No. 250 for Wet Locations. *Full compliance and test documentation is available for TM-21, LM-79, LM-80, ETL Listing to UL1598 and UL 8750 and Lighting Facts. Manufacturing Origin: US Manufactured and Assembled. Warranty: 10 Year L70 performance based warranty. For full warranty terms, please visit our website: www.lumecon.com Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009 Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice. Sheet/LWS-LHB_05142018 Technical Specifications Model Watts Equiv Delivered Lumens Efficacy LWS-LHB-120-X-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID 17,596 Lm 147 LPW LWS-LHB-120-D-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID 15,927 Lm 133 LPW LWS-LHB-120-X-CW 121W 4-LAMP T5HO, 6-LAMP T8, 400W HID 17,473 Lm 145 LPW LWS-LHB-120-D-CW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID 15,852 Lm 132 LPW LWS-LHB-150-X-NW 150W 4-LAMP T5HO, 6-LAMP T8, 400W HID 21,113 Lm 141 LPW LWS-LHB-150-D-NW 148W 4-LAMP T5HO, 6-LAMP T8, 400W HID 19,283 Lm 130 LPW LWS-LHB-150-X-CW 151W 4-LAMP T5HO, 6-LAMP T8, 400W HID 21,338 Lm 141 LPW LWS-LHB-150-D-CW 149W 4-LAMP T5HO, 6-LAMP T8, 400W HID 19,194 Lm 129 LPW LWS-LHB-190-X-NW 187W 6-LAMP T5HO, 8-LAMP T8 27,185 Lm 145 LPW LWS-LHB-190-D-NW 187W 6-LAMP T5HO, 8-LAMP T8 24,267 Lm 130 LPW LWS-LHB-190-X-CW 187W 6-LAMP T5HO, 8-LAMP T8 26,913 Lm 144 LPW LWS-LHB-190-D-CW 187W 6-LAMP T5HO, 8-LAMP T8 24,023 Lm 129 LPW LWS-LHB-250-X-NW 250W 8-LAMP T5HO 35,375 Lm 142 LPW LWS-LHB-250-D-NW 250W 8-LAMP T5HO 31,633 Lm 127 LPW LWS-LHB-250-X-CW 250W 8-LAMP T5HO 35,020 Lm 140 LPW LWS-LHB-250-D-CW 250W 8-LAMP T5HO 31,316 Lm 125 LPW LWS-LHB-285-X-NW 284W 8-LAMP T5HO 39,298 Lm 139 LPW LWS-LHB-285-D-NW 282W 8-LAMP T5HO 35,167 Lm 125 LPW LWS-LHB-285-X-CW 288W 8-LAMP T5HO 39,546 Lm 137 LPW LWS-LHB-285-D-CW 287W 8-LAMP T5HO 35,301 Lm 123 LPW The LWS-LHB linear High Bay fixture is the first of its kind in the Lumecon Workmen Series and delivers the illumination performance to replace conventional lighting systems, such as HID and fluorescent, one-for-one. The unique linear high bay design makes this a perfect energy saving solution for manufacturing, storage, warehousing and other indoor spaces with mounting heights from 10’ to 40’. WORKMEN SERIES

Description Performance Data - lumecon.com · National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. ... TC6 - Toggle & Cable

  • Upload
    hahanh

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Description Performance Data - lumecon.com · National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. ... TC6 - Toggle & Cable

LWS - LHBLED High Bay

Description Performance Data

Input Voltage: 120-277V

Lens: No lens (standard). An opaque diffused acrylic lens is available for applications where glare reduction is needed.

Mounting: Fixture mounting options include: Pendant, Surface Mount Brackets, Toggle & Cable, Safety Hook / No Cord, and Safety Hook with 6’ Cord.

NEMA Plug: Plug offerings are compliant to the standards set forth by the US National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options.

Color Temperature: 4000K NW (standard), 5000K CW.

LED Lifetime: All LED’s are rated for a minimum of 100,000 hours of continuous operation at ambient temperatures from -40°F/-40°C to 104°F/40°C.

Color Rendering Index (CRI): Minimum of 70 or higher.

Dimming: 0-10V standard dimming capability.

Surge Protection: Thermally protected 20kA/ 40kV varistor type surge suppressor is included and meets ANSI C136.2-2015: Extreme Level. Also meets IEC61643-11 Class II / EN61643-11 Type 2, and US Dept of Energy MSSLC Model Spec for surge protection. The device is wired in series with the luminaire input power in order to interrupt power to the luminaire when consumed, protecting the LED power supply and circuit boards from additional electrical surges.

Lumecon ETD™ System: The enhanced thermal dissipation system engines are thermally bonded to provide maximum thermal dissipation to the exterior of the fixture to ensure long life. To protect the light engine panel from moisture and corrosion, the LED light engine panel is uniformly coated with a UV stabilized acrylic polymer resin that meets MIL and ASTM dielectric standards, UL, and IPC standards for flammability, moisture resistance and thermal shock.

DesignLights Consortium® (DLC) Qualified Product: The 4000K NW and 5000K CW are DLC® Qualified. Unless noted, not all versions of this product may be DLC® qualified. For a complete list of Lumecon DLC® Qualified Products visit: www.designlights.org.

Certification Data: ETL Listed to UL 1598, UL 8750 and CSA 22.2 No. 250 for Wet Locations. *Full compliance and test documentation is available for TM-21, LM-79, LM-80, ETL Listing to UL1598 and UL 8750 and Lighting Facts.

Manufacturing Origin: US Manufactured and Assembled.

Warranty: 10 Year L70 performance based warranty. For full warranty terms, please visit our website: www.lumecon.com

Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved.

Note: Specifications and photometric data are subject to change at any time without notice.Sheet/LWS-LHB_05142018

Technical Specifications

Model Watts Equiv DeliveredLumens Efficacy

LWS-LHB-120-X-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID

17,596 Lm 147 LPW

LWS-LHB-120-D-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID

15,927 Lm 133 LPW

LWS-LHB-120-X-CW 121W 4-LAMP T5HO, 6-LAMP T8, 400W HID

17,473 Lm 145 LPW

LWS-LHB-120-D-CW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID

15,852 Lm 132 LPW

LWS-LHB-150-X-NW 150W 4-LAMP T5HO, 6-LAMP T8, 400W HID

21,113 Lm 141 LPW

LWS-LHB-150-D-NW 148W 4-LAMP T5HO, 6-LAMP T8, 400W HID

19,283 Lm 130 LPW

LWS-LHB-150-X-CW 151W 4-LAMP T5HO, 6-LAMP T8, 400W HID

21,338 Lm 141 LPW

LWS-LHB-150-D-CW 149W 4-LAMP T5HO, 6-LAMP T8, 400W HID

19,194 Lm 129 LPW

LWS-LHB-190-X-NW 187W 6-LAMP T5HO, 8-LAMP T8

27,185 Lm 145 LPW

LWS-LHB-190-D-NW 187W 6-LAMP T5HO, 8-LAMP T8

24,267 Lm 130 LPW

LWS-LHB-190-X-CW 187W 6-LAMP T5HO, 8-LAMP T8

26,913 Lm 144 LPW

LWS-LHB-190-D-CW 187W 6-LAMP T5HO, 8-LAMP T8

24,023 Lm 129 LPW

LWS-LHB-250-X-NW 250W 8-LAMP T5HO 35,375 Lm 142 LPW

LWS-LHB-250-D-NW 250W 8-LAMP T5HO 31,633 Lm 127 LPW

LWS-LHB-250-X-CW 250W 8-LAMP T5HO 35,020 Lm 140 LPW

LWS-LHB-250-D-CW 250W 8-LAMP T5HO 31,316 Lm 125 LPW

LWS-LHB-285-X-NW 284W 8-LAMP T5HO 39,298 Lm 139 LPW

LWS-LHB-285-D-NW 282W 8-LAMP T5HO 35,167 Lm 125 LPW

LWS-LHB-285-X-CW 288W 8-LAMP T5HO 39,546 Lm 137 LPW

LWS-LHB-285-D-CW 287W 8-LAMP T5HO 35,301 Lm 123 LPW

The LWS-LHB linear High Bay fixture is the first of its kind in the Lumecon Workmen Series and delivers the illumination performance to replace conventional lighting systems, such as HID and fluorescent, one-for-one. The unique linear high bay design makes this a perfect energy saving solution for manufacturing, storage, warehousing and other indoor spaces with mounting heights from 10’ to 40’.

WORKMEN SERIES

Page 2: Description Performance Data - lumecon.com · National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. ... TC6 - Toggle & Cable

LWS - LHBLED High Bay

Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.

Ordering Information

OCC Sensor Patterns

LWS-LHB - Options / Ordering Example: LWS-LHB-120-D-1-NW-X-X-X-X-X

WATTAGE

120 - 120 Watts150 - 150 Watts190 - 190 Watts 250 - 250 Watts285 - 285 Watts

LENS

X - NoneD - Diffused

VOLTAGE

1 - 120v - 277v

COLOR TEMPERATURE

NW - NeutralCW - Cool

CONTROLS/OCC SENSOR

X - NoneOC1 - On/OffOC3 - Dim/High Occupancy

FACTORY INSTALLED NEMA PLUG

X - None515P - 15 amp 120V Straight Blade PlugL515 - 15 amp 120V Twist Lock PlugL615 - 15 amp 240V Twist Lock PlugL715 - 15 amp 277V Twist Lock Plug *NEMA Plug used with TC6 & HC6 Mounts Only

BATTERY BACK-UP

X - NoneBB - Battery Back - Up

WIRE GUARD

X - NoneWG - Wire Guard

MOUNTING METHODS

X - NoneP - Pendant SM - Surface MountTC - Toggle & CableTC6 - Toggle & Cable / 6‘ Cord H - Safety Hook / No CordHC6 - Safety Hook / 6’ Cord

If OCC Sensor Option is selected, mounting height specifications need to be clarified: Mounting height between 0’ - 10’ Mounting height between 10’ - 40’ Mounting height over 40’+

Dimensions & Weights

Model Width Length Height(w/ junction

box)

Height (w/o junction

box)

Weight

LWS-LHB-120 24.94” 24.06” 4.625” 2.44” 11 lbs.

LWS-LHB-150 24.94” 24.06” 4.625” 2.44” 11 lbs.

LWS-LHB-190 24.94” 24.06” 4.625” 2.44” 12 lbs.

LWS-LHB-250 24.94” 24.06” 4.625” 2.44” 14 lbs.

LWS-LHB-285 24.94” 24.06” 4.625” 2.44” 14 lbs.

WORKMEN SERIES

Sheet/LWS-LHB_05142018

Page 3: Description Performance Data - lumecon.com · National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. ... TC6 - Toggle & Cable

LWS - LHBLED High Bay

Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.

Photometric IllustrationFor .ies files of this product, please visit the downloads tabs on the LWS-LHB product page: http://lumecon.com/products/lws-hb/

LWS-LHB-120

LWS-LHB-190

LWS-LHB-150

LWS-LHB-285

20’ MH 20’ MH

20’ MH 20’ MH

WORKMEN SERIES

Sheet/LWS-LHB_05142018

Page 4: Description Performance Data - lumecon.com · National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options. ... TC6 - Toggle & Cable

LWS - LHBLED High Bay

Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.

Performance Data

ELECTRICAL LOAD DATA

LWS - LHB - 120 109 120.64 1.12 0.64 0.56 0.48

LWS - LHB - 150 134 150.92 1.40 0.81 0.70 0.61

LWS - LHB - 190 172 187.22 1.73 1.00 0.87 0.75

LWS - LHB - 250 147 250.00 2.31 1.34 1.16 1.00

LWS - LHB - 285 172 288.28 2.67 1.54 1.33 1.16

Fixture Model 120V 208V 240V 277VDrive Current(mA)

System Watts(W)

AC Current Load (A)

LUMEN MAINTENANCEData in the table below references projected performance in a 25°C ambient and is based on 10,000 hours of LED testing. Performance data has been tested per IESNA LM-80-08 and projected per IESNA TM-21-11.

Use the lumen maintenance factor that corresponds to the desired number of operating hours below to calculate LLF.

LWP-LA-60 1.0 0.95 0.91 0.88 0.84

LWS - LHB - 120 1.0 0.98 0.93 0.89 0.84

LWS - LHB - 150 1.0 0.98 0.93 0.89 0.84

LWS - LHB - 190 1.0 0.92 0.83 0.76 0.67

LWS - LHB - 250 1.0 0.92 0.83 0.76 0.67

LWS - LHB - 285 1.0 0.92 0.83 0.76 0.67

Fixture Model 50,000 70,000 100,00025,0000

Lumen Maintenance Factors @ 25°C, by hours:

WORKMEN SERIES

Sheet/LWS-LHB_05142018