LWS - LHBLED High Bay
Description Performance Data
Input Voltage: 120-277V
Lens: No lens (standard). An opaque diffused acrylic lens is available for applications where glare reduction is needed.
Mounting: Fixture mounting options include: Pendant, Surface Mount Brackets, Toggle & Cable, Safety Hook / No Cord, and Safety Hook with 6’ Cord.
NEMA Plug: Plug offerings are compliant to the standards set forth by the US National Electrical Manufacturers Association (NEMA) and include both straight blade and twist lock options.
Color Temperature: 4000K NW (standard), 5000K CW.
LED Lifetime: All LED’s are rated for a minimum of 100,000 hours of continuous operation at ambient temperatures from -40°F/-40°C to 104°F/40°C.
Color Rendering Index (CRI): Minimum of 70 or higher.
Dimming: 0-10V standard dimming capability.
Surge Protection: Thermally protected 20kA/ 40kV varistor type surge suppressor is included and meets ANSI C136.2-2015: Extreme Level. Also meets IEC61643-11 Class II / EN61643-11 Type 2, and US Dept of Energy MSSLC Model Spec for surge protection. The device is wired in series with the luminaire input power in order to interrupt power to the luminaire when consumed, protecting the LED power supply and circuit boards from additional electrical surges.
Lumecon ETD™ System: The enhanced thermal dissipation system engines are thermally bonded to provide maximum thermal dissipation to the exterior of the fixture to ensure long life. To protect the light engine panel from moisture and corrosion, the LED light engine panel is uniformly coated with a UV stabilized acrylic polymer resin that meets MIL and ASTM dielectric standards, UL, and IPC standards for flammability, moisture resistance and thermal shock.
DesignLights Consortium® (DLC) Qualified Product: The 4000K NW and 5000K CW are DLC® Qualified. Unless noted, not all versions of this product may be DLC® qualified. For a complete list of Lumecon DLC® Qualified Products visit: www.designlights.org.
Certification Data: ETL Listed to UL 1598, UL 8750 and CSA 22.2 No. 250 for Wet Locations. *Full compliance and test documentation is available for TM-21, LM-79, LM-80, ETL Listing to UL1598 and UL 8750 and Lighting Facts.
Manufacturing Origin: US Manufactured and Assembled.
Warranty: 10 Year L70 performance based warranty. For full warranty terms, please visit our website: www.lumecon.com
Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved.
Note: Specifications and photometric data are subject to change at any time without notice.Sheet/LWS-LHB_05142018
Technical Specifications
Model Watts Equiv DeliveredLumens Efficacy
LWS-LHB-120-X-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID
17,596 Lm 147 LPW
LWS-LHB-120-D-NW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID
15,927 Lm 133 LPW
LWS-LHB-120-X-CW 121W 4-LAMP T5HO, 6-LAMP T8, 400W HID
17,473 Lm 145 LPW
LWS-LHB-120-D-CW 120W 4-LAMP T5HO, 6-LAMP T8, 400W HID
15,852 Lm 132 LPW
LWS-LHB-150-X-NW 150W 4-LAMP T5HO, 6-LAMP T8, 400W HID
21,113 Lm 141 LPW
LWS-LHB-150-D-NW 148W 4-LAMP T5HO, 6-LAMP T8, 400W HID
19,283 Lm 130 LPW
LWS-LHB-150-X-CW 151W 4-LAMP T5HO, 6-LAMP T8, 400W HID
21,338 Lm 141 LPW
LWS-LHB-150-D-CW 149W 4-LAMP T5HO, 6-LAMP T8, 400W HID
19,194 Lm 129 LPW
LWS-LHB-190-X-NW 187W 6-LAMP T5HO, 8-LAMP T8
27,185 Lm 145 LPW
LWS-LHB-190-D-NW 187W 6-LAMP T5HO, 8-LAMP T8
24,267 Lm 130 LPW
LWS-LHB-190-X-CW 187W 6-LAMP T5HO, 8-LAMP T8
26,913 Lm 144 LPW
LWS-LHB-190-D-CW 187W 6-LAMP T5HO, 8-LAMP T8
24,023 Lm 129 LPW
LWS-LHB-250-X-NW 250W 8-LAMP T5HO 35,375 Lm 142 LPW
LWS-LHB-250-D-NW 250W 8-LAMP T5HO 31,633 Lm 127 LPW
LWS-LHB-250-X-CW 250W 8-LAMP T5HO 35,020 Lm 140 LPW
LWS-LHB-250-D-CW 250W 8-LAMP T5HO 31,316 Lm 125 LPW
LWS-LHB-285-X-NW 284W 8-LAMP T5HO 39,298 Lm 139 LPW
LWS-LHB-285-D-NW 282W 8-LAMP T5HO 35,167 Lm 125 LPW
LWS-LHB-285-X-CW 288W 8-LAMP T5HO 39,546 Lm 137 LPW
LWS-LHB-285-D-CW 287W 8-LAMP T5HO 35,301 Lm 123 LPW
The LWS-LHB linear High Bay fixture is the first of its kind in the Lumecon Workmen Series and delivers the illumination performance to replace conventional lighting systems, such as HID and fluorescent, one-for-one. The unique linear high bay design makes this a perfect energy saving solution for manufacturing, storage, warehousing and other indoor spaces with mounting heights from 10’ to 40’.
WORKMEN SERIES
LWS - LHBLED High Bay
Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.
Ordering Information
OCC Sensor Patterns
LWS-LHB - Options / Ordering Example: LWS-LHB-120-D-1-NW-X-X-X-X-X
WATTAGE
120 - 120 Watts150 - 150 Watts190 - 190 Watts 250 - 250 Watts285 - 285 Watts
LENS
X - NoneD - Diffused
VOLTAGE
1 - 120v - 277v
COLOR TEMPERATURE
NW - NeutralCW - Cool
CONTROLS/OCC SENSOR
X - NoneOC1 - On/OffOC3 - Dim/High Occupancy
FACTORY INSTALLED NEMA PLUG
X - None515P - 15 amp 120V Straight Blade PlugL515 - 15 amp 120V Twist Lock PlugL615 - 15 amp 240V Twist Lock PlugL715 - 15 amp 277V Twist Lock Plug *NEMA Plug used with TC6 & HC6 Mounts Only
BATTERY BACK-UP
X - NoneBB - Battery Back - Up
WIRE GUARD
X - NoneWG - Wire Guard
MOUNTING METHODS
X - NoneP - Pendant SM - Surface MountTC - Toggle & CableTC6 - Toggle & Cable / 6‘ Cord H - Safety Hook / No CordHC6 - Safety Hook / 6’ Cord
If OCC Sensor Option is selected, mounting height specifications need to be clarified: Mounting height between 0’ - 10’ Mounting height between 10’ - 40’ Mounting height over 40’+
Dimensions & Weights
Model Width Length Height(w/ junction
box)
Height (w/o junction
box)
Weight
LWS-LHB-120 24.94” 24.06” 4.625” 2.44” 11 lbs.
LWS-LHB-150 24.94” 24.06” 4.625” 2.44” 11 lbs.
LWS-LHB-190 24.94” 24.06” 4.625” 2.44” 12 lbs.
LWS-LHB-250 24.94” 24.06” 4.625” 2.44” 14 lbs.
LWS-LHB-285 24.94” 24.06” 4.625” 2.44” 14 lbs.
WORKMEN SERIES
Sheet/LWS-LHB_05142018
LWS - LHBLED High Bay
Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.
Photometric IllustrationFor .ies files of this product, please visit the downloads tabs on the LWS-LHB product page: http://lumecon.com/products/lws-hb/
LWS-LHB-120
LWS-LHB-190
LWS-LHB-150
LWS-LHB-285
20’ MH 20’ MH
20’ MH 20’ MH
WORKMEN SERIES
Sheet/LWS-LHB_05142018
LWS - LHBLED High Bay
Email: [email protected] Website: www.lumecon.com Phone: 248-477-5009Copyright © 2018 Lumecon LLC. All Rights Reserved. Note: Specifications and photometric data are subject to change at any time without notice.
Performance Data
ELECTRICAL LOAD DATA
LWS - LHB - 120 109 120.64 1.12 0.64 0.56 0.48
LWS - LHB - 150 134 150.92 1.40 0.81 0.70 0.61
LWS - LHB - 190 172 187.22 1.73 1.00 0.87 0.75
LWS - LHB - 250 147 250.00 2.31 1.34 1.16 1.00
LWS - LHB - 285 172 288.28 2.67 1.54 1.33 1.16
Fixture Model 120V 208V 240V 277VDrive Current(mA)
System Watts(W)
AC Current Load (A)
LUMEN MAINTENANCEData in the table below references projected performance in a 25°C ambient and is based on 10,000 hours of LED testing. Performance data has been tested per IESNA LM-80-08 and projected per IESNA TM-21-11.
Use the lumen maintenance factor that corresponds to the desired number of operating hours below to calculate LLF.
LWP-LA-60 1.0 0.95 0.91 0.88 0.84
LWS - LHB - 120 1.0 0.98 0.93 0.89 0.84
LWS - LHB - 150 1.0 0.98 0.93 0.89 0.84
LWS - LHB - 190 1.0 0.92 0.83 0.76 0.67
LWS - LHB - 250 1.0 0.92 0.83 0.76 0.67
LWS - LHB - 285 1.0 0.92 0.83 0.76 0.67
Fixture Model 50,000 70,000 100,00025,0000
Lumen Maintenance Factors @ 25°C, by hours:
WORKMEN SERIES
Sheet/LWS-LHB_05142018