47
Designing and Operating an Energy Efficient Foodservice Facility Don Fisher, P. Eng. Fisher Consultants PG&E Food Service Technology Center 925-866-5770 [email protected] March 12, 2014 Winnipeg, MB

Designing and Operating an Energy Efficient Foodservice ... › wp-content › uploads › 1.1-Intro-to-EE-in-FS… · Efficient Foodservice Facility Don Fisher, P. Eng. Fisher Consultants

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Designing and

    Operating an Energy

    Efficient Foodservice

    Facility

    Don Fisher, P. Eng. Fisher Consultants

    PG&E Food Service Technology Center 925-866-5770 [email protected]

    March 12, 2014 Winnipeg, MB

  • Your online toolbox

    Reports

    Energy saving tips

    Design guides

    Cost calculators

    Energy Star

    Rebates

    www.Fishnick.com

  • What the Food Service Technology Center has been doing for over 20 years . . .

    • Appliance Testing

    • Real World Energy Use Monitoring

    • Kitchen Ventilation Laboratory

    • Site Survey/Energy Audits

    • Equipment Specification Review

    • Facility Design Assistance

    • Publications

    • Seminars

    • Utility Food Service Equipment Rebates

    • Online Resources

    www.FISHNICK.COM

  • – create ASTM Standard Test Methods

    & “miles-per-gallon” numbers for appliances

    The controlled environment “levels the playing field.”

    Appliance Testing Laboratory

  • A single appliance can consume more energy per year than your home!

    >

  • If your had to gas each appliance every morning, one’s perspective would quickly change…

  • Fryer $2,000/yr

    Range $1,000/yr

    Broiler $3,000/yr

    Manual Griddle $3,000/yr

    Ovens $2,000/yr

    Refrigerated Chef Base $400/yr

    Total Operating Cost $11,400

    Consider this line’s Energy Bill

  • Food Service is Energy Intensive!

    Source: www.energy.ca.gov/2006publications/CEC-400-2006-005/CEC-400-2006-005.PDF

    7 times more 5 times more

  • Commercial kitchens use 5 times more energy per square foot than rest of the

    building! kitchen

  • How does it break down?

    Food Prep

    35%

    HVAC

    28%

    Sanitation

    18%

    Lighting

    13%

    Refrig

    6%

  • Diversity: There are commercial kitchens in almost every type of building...

    • Hotels/Hospitality

    • Supermarkets

    • Prisons

    • Hospitals

    • Corporate Offices

    • Large Retail

    • Schools and Universities

  • ...and a huge variety of restaurants.

    • Kiosks

    • Cafes

    • Bars

    • Quick Service

    • Fast Casual

    • Full Service

    • Fine Dining

  • Each commercial kitchen can include dozens of energy uses.

    Example: A typical McDonald’s kitchen has about

    70 different pieces of gas and electric equipment.

  • $1.00/watt per year!

    • 100 watt bulb

    • Operating 24 hr/day

    • 365 days per year

    • @ $0.11/kWh

    100W x 24 x 365 = 657,000 Wh/yr

    = 657 kWh x $0.11/kWh

    = $96/yr

    100

    W

  • …at $1.20 per

    therm!

    (~$11.50 per GJ)

    • Rated input: 144,000 Btu/hr

    • Assume average consumption of 100,000 Btu/h

    • Over a 10 hr Day

    • 360 days per year

    • @ $1.20/therm

    100,000 Btu/h = 1 therm, so..

    1 therm x 10 hr x 360 days = 3600 therms/yr

    = 3600 therms x $1.20 = $4320/yr!

  • How efficient is this broiler?

  • Why not a lid?

  • What is Energy Efficiency?

    The percentage of energy consumed by an appliance that actually goes into cooking the food.

    Efficiency = = %

  • You buy and resell energy!

    Efficiency = energy you sold

    energy you bought

  • Food is Energy

    Like it or not, you are in the energy business!

  • Every dollar of energy that you save is pure profit!

  • But the commercial kitchen is a complicated and challenging

    environment!

  • And while kitchen operators are highly skilled at controlling

    labor and food costs…

  • …utility costs remain essentially

    “out of control”

  • Bottom Line: You can’t control what you don’t

    measure and monitor!

  • DATE DAYS THERMS therms/norm USE/DAY CHARGE

    Sep 30-Sep 30 565 565 18.8 307.58

    Oct 31-Oct 31 605 585 19.5 328.4

    Nov 1-Dec 31 802 776 25.9 577.11

    Dec 30-Dec 29 695 719 24 501.9

    Jan 31-Jan 32 786 737 24.6 583.64

    Feb 2-Mar 30 650 650 21.7 485.45

    Mar 1-Apr 30 666 666 22.2 492.89

    Apr 29-Apr 28 621 665 22.2 347.47

    May 31-May 32 665 623 20.8 371.14

    Jun 27-Jun 27 538 598 19.9 302.83

    Jul 28-Jul 31 571 553 18.4 320.58

    Aug 28-Aug 31 553 535 17.8 310.9

    Sep 28-Sep 31 594 575 19.2 332.95

    Tracking Utility Costs (aka Utility Accounting)

    • Under utilized tool in the foodservice world, despite spreadsheet literacy of this industry.

    • Foundation of an energy/water efficiency initiative - particularly for multi-unit operations.

    • 12-month consumption patterns tell important story.

  • Quick-Service Restaurant: 12-Month Electricity History

    0

    5000

    10000

    15000

    20000

    25000

    30000

    35000

    40000

    45000

    50000

    Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov

    kW

    h p

    er

    Mo

    nth

    Base Load

    Space Cooling

    Vestibule

    Heating

    Canadian Climate Zone

    ???

  • Quick-Service Restaurant: 12-Month Gas History

    0

    50

    100

    150

    200

    250

    300

    350

    Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov

    MB

    tu p

    er

    Mo

    nth

    Base Load

    Outdoor Air & Space

    Heating

    Canadian Climate Zone

  • Quick-Service Restaurant: 12-Month Water History

    0

    100

    200

    300

    400

    500

    600

    700

    800

    900

    Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov

    M3 W

    ate

    r

    Base Load

    Irrigation

    Canadian Climate Zone

  • Even a small drip adds

    up:

    50,000 gallons/yr

    water/sewer: $330

    gas: $640

    Total: $970!

    $1.20/therm gas & $5.00 per unit water/sewer

  • Coffee Chain removes a water waster...

  • The Audit Starts with

    Energy Accounting

  • Cooking Appliances

    Water Heating

    Ware Washing Exhaust System Lighting & Air Conditioning

    What an Energy Audit Tackles

    Refrigeration

  • http://www.fishnick.com/about/services/sitesurveys/

  • http://www.fishnick.com/about/services/sitesurveys/

  • Energy Efficient Cooking Equipment

  • 42

    ASTM Test Methods for 35 appliance types!

  • What have we learned?

  • Appliances are not created equal!

  • Refrigeration Fryers Hot Holding

    Cabinets

    Steamers

    www.energystar.gov/cfs

    ENERGY STAR Categories

    Ice Machines Dish Machines Griddles Convection

    Ovens

  • What makes an appliance more efficient?

    Induction

    Smart Controls

    Insulation

    Powered or

    IR Burners

    Good Heat Exchange

  • ...less efficient?

    No Insulation

    Poor Heat

    Exchange

    Manual Control

    Low-Cost

    Components

  • Insulation Saves Energy!

    40% Reduction in Energy Use