Designing and
Operating an Energy
Efficient Foodservice
Facility
Don Fisher, P. Eng. Fisher Consultants
PG&E Food Service Technology Center 925-866-5770 [email protected]
March 12, 2014 Winnipeg, MB
Your online toolbox
Reports
Energy saving tips
Design guides
Cost calculators
Energy Star
Rebates
www.Fishnick.com
What the Food Service Technology Center has been doing for over 20 years . . .
• Appliance Testing
• Real World Energy Use Monitoring
• Kitchen Ventilation Laboratory
• Site Survey/Energy Audits
• Equipment Specification Review
• Facility Design Assistance
• Publications
• Seminars
• Utility Food Service Equipment Rebates
• Online Resources
www.FISHNICK.COM
– create ASTM Standard Test Methods
& “miles-per-gallon” numbers for appliances
The controlled environment “levels the playing field.”
Appliance Testing Laboratory
A single appliance can consume more energy per year than your home!
>
If your had to gas each appliance every morning, one’s perspective would quickly change…
Fryer $2,000/yr
Range $1,000/yr
Broiler $3,000/yr
Manual Griddle $3,000/yr
Ovens $2,000/yr
Refrigerated Chef Base $400/yr
Total Operating Cost $11,400
Consider this line’s Energy Bill
Food Service is Energy Intensive!
Source: www.energy.ca.gov/2006publications/CEC-400-2006-005/CEC-400-2006-005.PDF
7 times more 5 times more
Commercial kitchens use 5 times more energy per square foot than rest of the
building! kitchen
How does it break down?
Food Prep
35%
HVAC
28%
Sanitation
18%
Lighting
13%
Refrig
6%
Diversity: There are commercial kitchens in almost every type of building...
• Hotels/Hospitality
• Supermarkets
• Prisons
• Hospitals
• Corporate Offices
• Large Retail
• Schools and Universities
...and a huge variety of restaurants.
• Kiosks
• Cafes
• Bars
• Quick Service
• Fast Casual
• Full Service
• Fine Dining
Each commercial kitchen can include dozens of energy uses.
Example: A typical McDonald’s kitchen has about
70 different pieces of gas and electric equipment.
$1.00/watt per year!
• 100 watt bulb
• Operating 24 hr/day
• 365 days per year
• @ $0.11/kWh
100W x 24 x 365 = 657,000 Wh/yr
= 657 kWh x $0.11/kWh
= $96/yr
100
W
…at $1.20 per
therm!
(~$11.50 per GJ)
• Rated input: 144,000 Btu/hr
• Assume average consumption of 100,000 Btu/h
• Over a 10 hr Day
• 360 days per year
• @ $1.20/therm
100,000 Btu/h = 1 therm, so..
1 therm x 10 hr x 360 days = 3600 therms/yr
= 3600 therms x $1.20 = $4320/yr!
How efficient is this broiler?
Why not a lid?
What is Energy Efficiency?
The percentage of energy consumed by an appliance that actually goes into cooking the food.
Efficiency = = %
You buy and resell energy!
Efficiency = energy you sold
energy you bought
Food is Energy
Like it or not, you are in the energy business!
Every dollar of energy that you save is pure profit!
But the commercial kitchen is a complicated and challenging
environment!
And while kitchen operators are highly skilled at controlling
labor and food costs…
…utility costs remain essentially
“out of control”
Bottom Line: You can’t control what you don’t
measure and monitor!
DATE DAYS THERMS therms/norm USE/DAY CHARGE
Sep 30-Sep 30 565 565 18.8 307.58
Oct 31-Oct 31 605 585 19.5 328.4
Nov 1-Dec 31 802 776 25.9 577.11
Dec 30-Dec 29 695 719 24 501.9
Jan 31-Jan 32 786 737 24.6 583.64
Feb 2-Mar 30 650 650 21.7 485.45
Mar 1-Apr 30 666 666 22.2 492.89
Apr 29-Apr 28 621 665 22.2 347.47
May 31-May 32 665 623 20.8 371.14
Jun 27-Jun 27 538 598 19.9 302.83
Jul 28-Jul 31 571 553 18.4 320.58
Aug 28-Aug 31 553 535 17.8 310.9
Sep 28-Sep 31 594 575 19.2 332.95
Tracking Utility Costs (aka Utility Accounting)
• Under utilized tool in the foodservice world, despite spreadsheet literacy of this industry.
• Foundation of an energy/water efficiency initiative - particularly for multi-unit operations.
• 12-month consumption patterns tell important story.
Quick-Service Restaurant: 12-Month Electricity History
0
5000
10000
15000
20000
25000
30000
35000
40000
45000
50000
Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov
kW
h p
er
Mo
nth
Base Load
Space Cooling
Vestibule
Heating
Canadian Climate Zone
???
Quick-Service Restaurant: 12-Month Gas History
0
50
100
150
200
250
300
350
Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov
MB
tu p
er
Mo
nth
Base Load
Outdoor Air & Space
Heating
Canadian Climate Zone
Quick-Service Restaurant: 12-Month Water History
0
100
200
300
400
500
600
700
800
900
Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov
M3 W
ate
r
Base Load
Irrigation
Canadian Climate Zone
Even a small drip adds
up:
50,000 gallons/yr
water/sewer: $330
gas: $640
Total: $970!
$1.20/therm gas & $5.00 per unit water/sewer
Coffee Chain removes a water waster...
The Audit Starts with
Energy Accounting
Cooking Appliances
Water Heating
Ware Washing Exhaust System Lighting & Air Conditioning
What an Energy Audit Tackles
Refrigeration
http://www.fishnick.com/about/services/sitesurveys/
http://www.fishnick.com/about/services/sitesurveys/
Energy Efficient Cooking Equipment
42
ASTM Test Methods for 35 appliance types!
What have we learned?
Appliances are not created equal!
Refrigeration Fryers Hot Holding
Cabinets
Steamers
www.energystar.gov/cfs
ENERGY STAR Categories
Ice Machines Dish Machines Griddles Convection
Ovens
What makes an appliance more efficient?
Induction
Smart Controls
Insulation
Powered or
IR Burners
Good Heat Exchange
...less efficient?
No Insulation
Poor Heat
Exchange
Manual Control
Low-Cost
Components
Insulation Saves Energy!
40% Reduction in Energy Use