26
100 100 300 300 300 Plastic DPM Compacted backfill Min. 300mm overlap with Bentonite Paste in the lap 1.1 Metre wide piece of SikaProof Bentonite fully bonded to cast concrete SikaProof Bentonite Detail no: SB01 - Nov 2013 Scale 1:5 Plastic DPM overlap - Compacted Backfill SikaSwell P Profile 2010H

Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

100 100

300 300

30

0

Plastic DPM

Compacted backfill

Min. 300mm overlap with Bentonite Paste in the lap

1.1 Metre wide piece of SikaProof Bentonite fully bonded to cast concrete

SikaProof Bentonite

Detail no: SB01 - Nov 2013

Scale 1:5

Plastic DPM overlap - Compacted

Backfill

SikaSwell P Profile 2010H

jktan
Stamp
Page 2: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

100 100

300 300

30

0

Min. 300mm overlap with Bentonite Paste in the lap

Minimum 6mm Coreflute board protection

Granular free drainage backfill

100mm perforated drainage pipe wrapped in geotextile filter fabric

Plastic DPM

1.1 Metre wide piece of SikaProof Bentonite fully bonded to cast concrete

Plastic DPM overlap - Free Draining

Backfill

SikaProof Bentonite

Scale 1:5

Detail no: SB02 - Nov 2013

SikaSwell P Profile 2010H

jktan
Stamp
Page 3: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

200mm

SikaSwellP Profile 2010H

SikaProof Bentonite patches

Compacted backfill

Fill void with Sika Grout 212

Minimum 50mm site concrete

Mortar pads

SECTION

SikaProof Bentonite

Allow 300mm overlap of SikaProof Bentonite to laponto under slab waterproof

SikaSwellP Profile 2010H

SikaProof Bentonite preappliedin pre-cast yard

Detail no: SB03 - Nov 2013

Scale 1:10

Precast Lift Pit Detail - Compacted

Backfill

jktan
Stamp
Page 4: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

SikaSwellP Profile 2010H

50mm Site concrete

50mm Site concrete

Compacted backfill

SECTION

SikaSwellP Profile 2010H

Note:Laps in SikaProof Bentonite to be taken minimum300mm past corner angles and construction joints

40mm angle fillet of SikaProof Bentonite Paste

SikaProof Bentonite preapplied toinside face of outside shutterprior to concrete pour

SikaProof Bentonite

Scale 1:10

Detail no: SB04 - Nov 2013

Typical Lift Pit - Cast In-situ

Compacted Backfill

jktan
Stamp
Page 5: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Compacted backfill

Detail no: SB05 - Nov 2013

SikaProof Bentonite shot fired to wall using mechanicalfasteners or preapplied to inside face of outside shutter.

SikaProof Bentonite

Pre-cast - Compacted Backfill

Application to Walls

Scale 1:5

jktan
Stamp
Page 6: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Note:Blowholes and minor imperfections shall be bagged with Sika MonoTop Fairing Coat or other appropriate motar.Not required if pre-applied to shutter.

SikaProof Bentonite shot fired to wall using mechanicalfasteners or preapplied to inside face of outside shutter.

Granular free drainage backfill

Minimum 6mm Coreflute board protection

In-situ Wall - Free Draining Backfill

Application to Walls

SikaProof Bentonite

Scale 1:5

Detail no: SB06 - Nov 2013

jktan
Stamp
Page 7: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Compacted backfill

In-situ Wall - Compacted backfill

Application to Walls

SikaProof Bentonite shot fired to wall using mechanicalfasteners or preapplied to inside face of outside shutter.

Note:Blowholes and minor imperfections shall be bagged with Sika MonoTop Fairing Coat or other appropriate motar.Not required if pre-applied to shutter.

SikaProof Bentonite

Scale 1:5

Detail no: SB07 - Nov 2013

jktan
Stamp
Page 8: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

100 100

10

0

100

Second layer of SikaProof Bentonite

Jubilee clip

Boxed Out Pipe Penetration

Free Draining Backfill

SikaProof Bentonite

SikaSwell P Profile 2010H

SikaProof Bentonite

Minimum 6mm Coreflute board protection

Detail no: SB08 - Nov 2013

Sika Grout 212 finished flushwith surface

Scale 1:5

jktan
Stamp
Page 9: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

100 100

Detail no: SB09 - Nov 2013

SikaSwell P Profile 2010H

SikaProof Bentonite

Sika Grout 212 finished flushwith surface

150mm Concrete haunchingaround pipe with tie to wall

Boxed Out Pipe Penetration

Free Draining Backfill

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 10: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

10

0

100

Second layer of SikaProof Bentonite

Jubilee clip

Minimum 6mm Coreflute board protection

Detail no: SB10 - Nov 2013

Cast In Pipe Penetration

Free Draining Backfill

SikaProof Bentonite

SikaSwell P Profile 2010H

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 11: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

SikaProof Bentonite

150mm Concrete haunchingaround pipe with tie to wall

SikaSwell P Profile 2010H

Detail no: SB11 - Nov 2013

SikaProof Bentonite

Scale 1:5

Cast In Pipe Penetration

Compacted Backfill

jktan
Stamp
Page 12: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Concrete Walls - External Corner

- Post Fixed

SikaProof Bentonite shot fired to wall using mechanical fasteners or preapplied to inside face of outside shutter.

Note:Blowholes and minor imperfections shall be bagged with Sika MonoTop Fairing Coat or other appropriate motar.

External corner rounded off to6mm radius

SikaProof Bentonite

Detail no: SB12 - Nov 2013

Scale 1:5

jktan
Stamp
Page 13: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

SikaProof Bentonite

Concrete Walls - Internal Corner

- Post Fixed

40mm sand / cement cove

Detail no: SB13 - Nov 2013

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 14: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

15

01

50

Detail no: SB14 - Nov 2013

Pre-cast - Free Draining

Termination at Ground Level

4mm Sikalastic 152 taken 150mm above ground leveland lapped 150mm behind SikaProof Bentonite with40mm wide strip of SikaProof Bentonite Paste in the lap.

SikaProof Bentonite preapplied to formwork in pre-cast yard

Sikaflex 11 FC

SECTION

Ground level

25mmX2mm aluminium termination bar fixed @ maximum 300mm centres with mechanical fastener

Granular free drainage backfill

Minimum 6mm Coreflute board protection

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 15: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

200mm Square patch of SikaProof Bentoniteand bedded into paste and fastened into place

Detail no: SB15 - Nov 2013

Concrete Walls - Tie Bolt Hole

Compacted or Free Draining Backfill

SikaProof Bentonite

Sika Grout 212 finished flushwith surface

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 16: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

15

01

50

Sikaflex 11 FC

4mm Sikalastic 152 taken 150mm above ground leveland lapped 150mm behind SikaProof Bentonite with40mm wide strip of SikaProof Bentonite Paste in the lap.

SikaProof Bentonite shot fired to wall using mechanicalfasteners or preapplied to inside face of outside shutter.

Blowholes and minor imperfections shall be bagged with Sika MonoTop Fairing Coat or other appropriate motar.

Detail no: SB16 - Nov 2013

Pre-cast - Free Draining

Termination at Ground Level

Granular free drainage backfill

SECTION

Minimum 6mm Coreflute board protection

25mmX2mm aluminium termination bar fixed @ maximum 300mm centres with mechanical fastener

Ground level

SikaProof Bentonite

Scale 1:5

jktan
Stamp
Page 17: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Note:Blowholes and minor imperfections shall be bagged with Sika MonoTop Fairing Coat or other appropriate motar.

SikaProof Bentonite preapplied to formwork in pre-cast yard

Granular free drainage backfill

Minimum 6mm Coreflute board protection

Pre-cast - Free Draining Backfill

Application to Walls

SikaProof Bentonite

Scale 1:5

Detail no: SB17 - Nov 2013

jktan
Stamp
Page 18: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Water Proof to Pile Caps

Reinforced concrete

SikaSwell - P Profile Type 2010Hadhered with SikaSwell S-2 aroundprofile of pipe with 100mm cover

SikaProof Bentonite

40mm Fillet of SikaProof Bentonite Paste around profile of pile cap

Sikalastic 152 taken down sides of pile and below line of membrane

SikaProof Bentonite

Detail no: SB18 - Nov 2013

Scale 1:5

jktan
Stamp
Page 19: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Scale 1:20

Detail no: SB19 - Nov 2013

SikaProof Bentonite shot fired to wall using mechnical fasterners with washers. Waterproofing to secant piles shall be installed prior to the application of SikaProof Bentonite forunderslab waterproofing.

SikaProof Bentonite dressed around pile and taken 300mmout horizontal to piles to be cut and splayed to receiveunderslab application.

Apply a 40mm fillet of SikaProof Bentonite Pasteover SikaProof Bentonite along profile of the piles.

Secant Piles

Water Proof to Secant Piles - Step 1

SikaProof Bentonite

jktan
Stamp
Page 20: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Detail no: SB20 - Nov 2013

Secant Piles

Cut SikaProof Bentonite to follow the profile of the piles

Waterproofing to underslab shall be installed afterthe application of the SikaProof Bentonite to the piles.

Place SikaProof Bentonite tight against secant piling.

Scale 1:20

Water Proof to Secant Piles - Step 2

SikaProof Bentonite

jktan
Stamp
Page 21: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

30

0

Sheet piling

Reinforced concrete

SikaProof Bentonite

Step 3

Step 2

Step 1

SikaProof Bentonite shot fired to steel sheet pilingusing approved fixings and following the profile of the piles.

Apply a 40mm fillet of SikaProof BenronitePaste over 300mm cut and splayed SikaProof Bentonite along the profile of the piles

Cut SikaProof Bentonite to follow the profile of the piles

Place SikaProof Bentonite tightagainst sheet piling

Waterproofing to underslab shall be installed after the application of the SikaProof Bentonite

to the piles

Detail no: SB21 - Nov 2013

Water Proof to Steel Sheet Piling

Not To Scale

SikaProof Bentonite

jktan
Stamp
Page 22: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

Secondary overlap of SikaProof Bentonite with 60mm wide Bentonite Paste in lap

Self compacting concrete mix

SikaProof Bentonite pre-fixed to precast panel

SikaSwell - P Profile Type 2010Hadhered with SikaSwell S-2

Note:Blowholes and imperfections shall be bagged with Sika MonoTopFaining Coat or other appropriate cement based mortar

Detail no: SB22 - Nov 2013

SikaProof Bentonite

Pre-cast Stitch Joint Detail

Easy Access

Scale 1:5

jktan
Stamp
Page 23: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

PEF rod

Detail no: SB23 - Nov 2013

100mm wide strip of SikaProof Bentonite

Sika Grout 212

Self compacting concrete with Sika Control 40

SikaProof Bentonite pre fixed at Pre-cast yard

SikaProof Bentonite

Pre-cast Stitch Joint Detail for

Limited Access Installation 1

Scale 1:5

jktan
Stamp
Page 24: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

150 (N.T.S)

50 (

N.T

.S)

150 (N.T.S)

SikaSwell P Profile 2010H

SikaProof Bentonite

Sika Grout 212 SikaProof Bentonite bonded in pre-cast beds to panel

SikaProof Bentonite pre-fixed to 6mm Hardiflex board taken 150mm past joint edge either side with 150mm SikaProof Bentonite Paste in both laps.

Pre-cast Stitch Joint Detail for

Limited Access Installation 2

Detail no: SB24 - Nov 2013

Scale 1:5

jktan
Stamp
Page 25: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

100 100

300

min

.

Pre-cast Panel / Footing Junction

Scale 1:5

Detail no: SB25 - Nov 2013

Floor Level

Min. 200mm overlapto base of footing

Minimum 6mm Coreflute board protection

Compacted backfill

SECTION

Note:

Timber boxing to rear of footing and

timber panel guide must be removed.SikaProof Bentonite preapplied in pre-cast yard

SikaSwell P Profile 2010H

Sika Grout 212 fillet

SikaProof Bentonite

SikaProof Bentonite

jktan
Stamp
Page 26: Detail no: SB01 - Nov 2013 · 2 days ago · Detail no: SB25 - Nov 2013 Floor Level Min. 200mm overlap to base of footing Minimum 6mm Coreflute board protection Compacted backfill

150 (N.T.S) 150 (N.T.S)

50 (

N.T

.S)

Sika Grout 212

SikaProof Bentonite bonded in pre-cast beds to panels

Pre-cast Panel sealant joint Detail

for Limited Access Installations

SikaProof Bentonite

SikaProof Bentonite pre-fixed to 6mm Hardiflex board taken 150mm past joint edge either side with 150mm SikaProof Bentonite Paste in both laps.

Scale 1:5

Sikaflex Sealant on PEF rod

Detail no: SB26 - Nov 2013

jktan
Stamp