Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
HWS
HWSHWS
HWS
9.000
9.100
9.200
9.300
9.400 9.5
00
9.60
0
9.70
0
9.80
0
9.90
0
10.0
00
10.10
0
10.2
00
10.30010.400
10.500
10.097
10.392
10.744
10.914
11.14811.203
11.34111.067
10.781
10.580
10.306
9.638
8.852
9.066
8.7698.804
8.915
8.872 9.084 9.870
10.117
10.80410.103
9.880
9.636
9.610
9.855 10.216
TOP
OF K
ERB
ED 14163 OPW - 01 C
issue
Date 1 MAY 2014
Scale 1: 150 @ A3Design DrawnSheet 01 OF 03
JV
CLIENT
DWGTITLE
JV
LANDSCAPE PLAN - OPERATIONAL WORKS
DIAL BEFORE
YOU DIG
WWW. 1100.com.au
LANDSCAPE DESIGN INTENT BY MURPHY HOMES PTY LTD
SELECT EXPOSED
AGGREGATE
DRIVEWAY
1800 HIGH
RETURN
TIMBER PALING
FENCE & GATE
1800 HIGH
RETURN
TIMBER PALING
FENCE & GATE
1800 HIGH TIMBER
PALING FENCE
TURF
TURF
1 x CUP ana
45 litre
(2.0m high at planting)
1 x ACM smi
45 litre
(2.0m high at planting)
6 x DIE bic
4 x TRA Tri
3 x SYZ Res
1.0m high at planting
TURF
TURF
TE
TE
TE
TE
TE
TE
TE
TE
TE
TE
TE
TURF
TURF
1800 HIGH TIMBER
PALING FENCE
1800 HIGH TIMBER PALING FENCE
TO BE LAPPED / CAPPED & PAINTED
WITH EXPRESSED POSTS.
ARTICULATED FENCE
1800 HIGH TIMBER
PALING FENCE
2 x DIE bic
4 x DIE bic
3 x SYZ Res
1.0m high at planting
4 x TRA Tri
1 x ACM smi
45 litre
(2.0m high at planting)
4 x DIE bic
5 x MET LD
TE
1800 HIGH TIMBER
PALING FENCE
DETAILS PLAN - OPERATIONAL WORKS
DIAL BEFORE
YOU DIG
WWW. 1100.com.au
c
ed
MIN 1500mm
c
ed
c
ed
Tree Planting Distances from Services
ED 14163 OPW - 02 C
issue
Date 1 MAY 2014Scale
Design DrawnSheet 02 OF 03
JV
CLIENT
DWGTITLE
JV
SPECIFICATION AND PLANT SCHEDULE PLAN - OPERATIONAL WORKS
DIAL BEFORE
YOU DIG
WWW. 1100.com.au
SPECIFICATION FOR LANDSCAPE WORKS
GENERAL CONDITIONS
SITE PREPARATION /
EARTHWORKS
MATERIALS / SERVICES
HARDSCAPE
PLANT MANAGEMENT
SOFTSCAPE
IRRIGATION
SCOPE PERFORMANCE
TURF
LANDSCAPE
ESTABLISHMENT PERIOD
ALL LANDSCAPE CONSTRUCTION WORK IS TO BE CARRIED OUT IN COMPLIANCE WITH RELEVENT COUNCIL APPROVALS AND TO
INDUSTRY BEST PRACTICE. ANY CHANGES FROM DESIGN DOCUMENTATION MUST BE APPROVED BY PROJECT LANDSCAPE ARCHITECT
PRIOR TO CONSTRUCTION ON SITE.
EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE UNDERTAKEN WHERE NECESSARY TO ENSURE NO DETRIMENTAL EFFECT
TO DOWNSTREAM WATERWAYS OR NEIGHBOURING SITES.
PRIOR TO COMMENCEMENT OF WORKS, EXISTING SITE CONDITION IS TO BE DOCUMENTED BY CONTRACTOR. ALL EXISTING AND
PROPOSED SERVICES ON SITE ARE TO BE LOCATED AND CLEARLY IDENTIFIED. ALL BUILDING RUBBISH AND DELETERIOUS MATERIALS
ARE TO BE REMOVED FROM SITE TO APPROVED WASTE LOCATION.
LANDSCAPE AREAS SHALL BE SCARIFIED TO A DEPTH OF 150mm TO PROMOTE GOOD GROWTH FOR TURF AND PLANTING.
ALL MATERIALS TO BE USED IN THE CONSTRUCTION OF THE DESIGNED LANDSCAPE ARE TO BE OF AND INDUSTRY STANDARD QUALITY
AND FROM A SUSTAINABLE SOURCE WHERE POSSIBLE. NO MATERIALS USED ON SITE SHALL BE TOXIC TO HUMANS, ANIMALS OR
PLANTS.
ALL SELECT ITEM MATERIALS ARE TO BE APPROVED BY CLIENT PRIOR TO CONSTRUCTION ON SITE.
PROVIDE SERVICE CONDUITS TO ALL GARDEN BEDS FOR IRRIGATION AND DRAINAGE PURPOSE. PROVIDE CONDUITS FOR LIGHTING
WHERE REQUIRED.
ENSURE ADEQUATE DRAINAGE TO PLANTING AREAS FOR SPECIFIC SITE SOIL CONDITIONS VIA THE USE OF SLOTTED AGRICULTURAL
DRAIN (SELECT TYPE FOR APPLICATION ), OVERLAND FLOW PATHS WITHIN GARDENS ( SELECT RIVER GRAVEL ON GEOFABRIC
MATERIAL) AND SURFACE STORMWATER PITS ( LOCATED IN GENERALLY CONCEALED POSITIONS ).
PROPOSED HARDSCAPE ITEMS ARE TO BE CONSTRUCTED TO AUSTRALIAN STANDARDS AND RELEVENT COUNCIL CODES BY A
SUITABLY LICENCED CONTRACTOR. WORKPLACE HEALTH AND SAFETY REGULATIONS MUST BE IMPLEMENTED DURING CONSTRUCTION
PHASE.
SETOUT OF ALL SOFTSCAPE AREAS TO BE IN ACCORDANCE WITH APPROVED PLANS. PLANTING AREAS TO BE MOUNDED TO ACHIEVE
ADEQUATE DRAINAGE AND AESTHETIC PRESENTATION.
SOIL: A GOOD QUALITY FRIABLE, MODERATELY DRAINING, ORGANIC ENRICHED LANDSCAPING SOIL MIX SHALL BE IMPORTED FROM AN
APPROVED SOURCE. THE SOIL SHOULD NOT CONTAIN ANY CLAY AND BE FREE FROM CONTAMINENTS SUCH AS WEEDS, STICKS AND
ROCKS. IMPLEMENTATION WITHIN GARDEN AREAS TO A MIN. OF 300mm DEPTH.
ORGANIC MULCH: HOOP PINE MULCH IN ITS VARIETY OF FORMS IS TO BE SUPPLIED AND INSTALLED TO A MIN. DEPTH OF 100mm. MULCH
IS TO BE FREE OF FOREIGN MATTER INCLUDING WEEDS, SOIL, STICKS AND ROCKS. AVOID PLACEMENT OF MULCH AGAINST STEM OR
TRUNK OF PLANTS. GRADE MULCH TO BE SELF RETAINED WITHIN GARDEN EDGING.
GRAVEL MULCH: SELECTED WASHED RIVER MULCH GRADED IN SIZE AND COLOUR. USE IN AREAS AS SPECIFIED ON PLANS. TO BE USED
TO SEPERATE ORGANIC MULCH FROM THE WALLS OF BUILDINGS, ADJACENT PATHS AND TOO FACILITATE DRAINAGE WITHIN GARDEN
BEDS. MIN. DEPTH TO BE TWICE THE DIAMETER OF THE LARGEST PEBBLE.
ALL PLANT SPECIES ARE DETAILED WITHIN THE PLANT SCHEDULE . NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR ACCEPTANCE BY
COUNCIL AND PROJECT LANDSCAPE ARCHITECT.
THE CONTRACTOR SHALL OBTAIN ALL PLANTS AS SPECIFIED FROM AN ACCREDITED NURSERY OR OTHER APPROVED SOURCE. PLANTS
SHALL BE PRE-WATERED PRIOR TO ARRIVING ON SITE.
PLANTS SHALL BE HEALTHY, HARDY AND OF GOOD FORM. THE ROOT SYSTEM OF EACH PLANT SHOULD NOT BE ROOTBOUND AND BE
CONDUCIVE TO SUCCESSFUL TRANSPLANTATION. ALL PLANTS TO BE PEST AND DISEASE FREE WITH CONTAINERS FREE FROM WEEDS.
STREET TREE SPECIES ARE TO COMPLY WITH NATSPEC AND RELEVENT COUNCIL CONDITIONS.
STAKE TREES WITH A MIN. OF TWO 50x50 HWD STAKES AND HESSION STRAP OR SIMILAR AS NOT TO DAMAGE TREE. FIGURE '8' DETAIL
RECOMMENDED.
NO TYPE OF STAKE TO BE PLACED THROUGH ROOTBALL OF PLANT AT ANY TIME.
EACH PLANT TO HAVE ADDED WATER CRYSTALS TO PLANTING HOLE AND WATERED IN AFTER PLANTING AS REQUIRED.
PLANT STOCK MAY BE REJECTED IF NOT CONFORMING WITH ABOVE SPECIFICATIONS.
TURF SHALL CONSIST OF A DENSE, WELL ROOTED, VIGOROUS GRASS GROWTH WITH MIN. 25mm OF TOPSOIL. TURF IS TO BE
DELIVERED TO SITE WITHIN 24 HOURS OF BEING CUT. TURF SHOULD BE FREE FROM DELETERIOUS MATERIAL INCLUDING WEEDS,
SEEDS OR ROOTS INCLUDING NUT GRASS AND OXALIS. TURF SHALL BE SUPPLIED IN UNIFORM SIZE IN UNBROKEN CONDITION.
MOISTURE LEVEL OF TURF TO REMAIN CONSISTANT DURING LAYING. TURF TO BE LAID ALONG CONTOUR AND PINNED IF GREATER
THAN 1:4 SLOPE.
PREPARE SUBGRADE TO A LEVEL BASE WITH AN APPROVED TOPSOIL AND SPREAD UNDER TURF FERTILIZER AT RECCOMMENDED
RATE. TURF TO FINISH LEVEL WITH PATHS, EDGES AND KERBS AFTER ROLLING AND SETTLEMENT.
IRRIGATION TO BE INSTALLED BY A SUITABLY QUALIFIED CONTRACTOR AND BE INSTALLED IN ACCORDANCE WITH ALL COUNCIL WATER
REGULATIONS.
THE MOST WATER EFFICIENT METHOD OF IRRIGATION IS TO BE USED, CONNECTED TO TANK SUPPLY WHERE POSSIBLE.
CONDUITS TO BE LAID TO ALL GARDEN AREAS TO PROVIDE A REGULATED COVERAGE. FLUSH AND PRESSURE TEST PRIOR TO
COMMISSIONING.
PROVIDE AS CONSTRUCTED DRAWINGS CLEARLY SHOWING LOCATION OF ALL IRRIGATION COMPONENTRY.
THE CONTRACTOR SHALL BE RESONSIBLE FOR THE CARE AND MAINTENANCE OF ALL LANDSCAPE WORKS FOR A PERIOD OF 13 WEEKS
AFTER COMPLETION.
MAINTENANCE IS TO INCLUDE MOWING OF TURF, REMOVAL AND SPRAYING OF WEEDS, PRUNING AND TRIMMING OF SHRUBS WHERE
REQUIRED, REPLACEMENT OF DEAD OR DISEASED PLANT STOCK AND CORRECT WORKING OF IRRIGATION SYSTEM.
WATER IS TO BE PROVIDED TO ALL SOFT LANDSCAPING AT A REQUIRED RATE DURING THE ESTABLISHMENT PERIOD TO ENSURE
HEALTHY AND VIGOROUS GROWTH.
element design
TM
PLANT SCHEDULE
TREE SPECIES
Code Botanical Name Common Name
GROUNDCOVER SPECIES
QuantitySize
Code Botanical Name Common Name QuantitySize
Code Botanical Name Common Name QuantitySize
element design
SHRUB SPECIES
TM
Contractor to confirm plant quantities prior to ordering
(REFER ADDITIONAL NOTE)
ACM smi Acmena smithii Small Leaf Lilly Pilly
245 litre
Tree Planting Distances from Services
ED 14163 OPW - 03 C
issue
Date 1 MAY 2014Scale
Design DrawnSheet 03 OF 03
JV
CLIENT
DWGTITLE
JV
SYZ Res Syzygium Resilence Hedging Lilly Pilly
6300 pot
MET col Metrosideros "Little Dugald" Little Dugald
5200 pot
CUP ana Cupaniopsis anacardiodes Tuckeroo145 ltre
TRA tri Trachelospermum 'Tricolour' Tricolour Jasmine 140 pot8
DIE bic Dietes bicolor Wild Iris
16
140 pot
OFFICE USE ONLYAMENDMENTS TO SCHEDULE
REV.STAGED
PLANDATE DESCRIPTION OF CHANGE TO SCHEDULE
15.01.14 A WD'S WORKING DRAWINGS
07.04.14 B WD'S WORKING DRAWINGS
22.04.14 C WD'S WORKING DRAWINGS
28.04.14 D WD'S WORKING DRAWINGS
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
00028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Cover Sheet
DRAWING LIST
000 Cover Sheet
001 3D Perspectives
100 Site Plan
200 Ground Floor
202 Roof Plan
300 Elevations
301 Elevations
302 Sections
400 Slab Layout Plan
500 Electrical Plan
700 Kitchen Details
701 Wet Area Details
All material shall be new UNO. Reused items to be checked for soundness etc. prior to use.
- AS PER ENGINEERS DETAILS
b. Walls to have a continuous cavity kept clear of mortar droppings.
a. Brickwork to conform to AS 3700 1998 Masonry in buildings
c. Ceramic tiles or other approved impervious material to walls above showers to 1800mm min above floor.
c. Brick foundation walls under timber floors to have vents at 7500 sq mm per metre length of externalwall. (Approx. 1 brick sized vent every 2 metres.)
a. Floor surfaces to bath & laundry shall be impervious, with junctions between wall and floor flashed to preventmoisture penetration into walls.
Dimensions take preference to scale and are to structure not finish.
Work shall comply with the Building Code of Australia, Building Act Qld, and all relevant current AustralianStandards. Any outdated Standards listed in these notes are to be taken to refer to the current edition.
Check and verify dimensions and confirm any existing dimensions marked.
All dimensions in millimetres.
d. Ground surface to be sloped 1:20 (min) away from building for 900mm (min) and to a pointwhere ponding will not occur near the building.
b. Footings shall be placed as per builders spec or engineers details.
c. Footings to found in non-expansive natural material having a minimum allowable bearing capacity of 100kPa.
e. Dish drains and ag-pipes to be provided as indicated to facilitate drainage of water awayfrom building into drainage system.
It is at the Builders discretion to position bulkheads or service panels underfloor framing to accommodate plumbing services
a. Site to be excavated and or filled to levels shown.
6. UNO = Unless Noted Otherwise.
OMP = Outer Most Point. DPC = Damp Proof Course.
a. All sizes of timber members deduced from AS 1684
c. Sizes of timber members may vary upon ordering requirements but must remain within the guidelinesof the said reference material.
b. All remaining sizes of items deduced from Australian Domestic Construction Manual orrelevant manufacturers specification.
Manufacturers specification means a current approved specification for use under the conditionsapplicable.
STEELWORK
BRICKWORK
REINFORCED CONCRETE
AS APPLICABLE - REFER DWG FOR MATERIALS USED.
WET AREA SURFACES
FRAMING TIMBER
BLOCKWORK
MATERIALS AND CONSTRUCTION
GENERAL NOTES:
SITE WORKS
DESIGN LOADS
c.Any variation at construction stage to comply with Council policy.
b. Position of retaining walls may vary and must be verified by builder prior to commencement.a. All retaining walls are to comply with Council policy on retaining walls and embankments on residential building sites.
RETAINING WALLS
- AS PER ENGINEERS DETAILS
- AS PER ENGINEERS DETAILS
- AS PER AS 1684. 1999 National timber framing code
4.3.
2.1.
5.
7.
d. Provide wall ties at 600mm spacings both vertical and horizontal andwithin 300mm of articulation joints. Brick ties to be stainless steel.
STAIR REQUIREMENTS
Min. tread 240mm, Min.riser 115mm, Max. riser 190mm. Space between open treads Max. 125mm. Treads to be a nonslip surface. Balustrades : min. 1000mm above landings with max. opening of 125mm and in accordanced with BCA3.9.2. For stainless steel ballustrade, refer to table 3.9.2.1 (Wire balustrade construction - required wire tension andmaximum permissible deflection) of the BCA
b. All wet areas to comply with BCA 3.8.1.2 and AS 3740. Splashbacks shall be imperviousfor 150mm above sinks, troughs and hand basins within 75mm of the wall.
TILED DECKS:
Tiled decks over livable areas are to be, in the following order over the floor joists : 19mm compressedFC sheet, with one layer of parchem emerproof 750 with a second layer of sand seed with a DFT of1300 micron, installed to manuf. specifications, and floor tiles over, all corners to have 20mm masticsealant under parchem emerproof 720
SAFTEY GLAZING TO BE USED IN THE FOLLOWING CASES:
a. All rooms - within 500mm vertical of the floorb. Bathrooms within 1500mm vertical of the floorsc. Fully glazed doorsd. Shower screense. Within 300mm of a door and <1200mm above floor levelf. window sizes are nominal only, actual sizes will vary with manufacturer, flashing all round
These plans are to be read in conjuction with any structural and civil engineering computions and drawings
All buildings shall be protected against termite attack in accordance with AS 3660.1 and a durable notice shallbe left in the meter box indicating type of barrier and required periodical inspections
All works shall comply with but not limited to the building code of australia and theaustralian standards listed below.
AS 1288 - 1994 GLASS IN BUILDINGS SELECTION AND INSTALLATION
AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
AS 1684 - 1999 NATIONAL TIMBER FRAMING CODEAS 2049 - 1992 ROOF TILES
AS 2050 - 1995 INSTALLATION OF ROOF TILES
AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION
AS /NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGS
AS 3600 - 1994 CONCRETE STRUCTURESAS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES
AS 3700 - 1998 MASONRY IN BUILDINGSAS 3786 - 1993 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
AS 4055 - 1992 WIND LOADING FOR HOUSESAS 4100 - 1996 STEEL STUCTURES
Smoke detectors to be hard wired with emergency back-up and comply with AS3786
Wind speed as nominated on bracing plan or soil test
Provide lift-off hinges to WC or open out door or min. 1200mm clearance from door to pan.
All construction materials supplied must take into account proximity to coastal or industrial environments, in accordance with manuf. specifications
These plans are protected by copy right and are the property of the author.
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
00128.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
3D Perspectives
HWS HWS
K
K
LTBM
E
E
S
9.0
00
9.100
9.200
9.30
0
9.400
9.50
0
9.6
00
9.7
00
9.8
00
9.9
00
10.0
00
10.100
10.2
00
10.3
00
10.4
00
10.5
00
10.003
10.097
10.392
10.744
10.914
11.148
11.203
11.341
11.067
10.781
10.580
10.306
9.638
8.852
9.066
8.769
8.915
9.084
9.682
9.870
10.117
10.804
10.10
3
9.880
9.636
9.610
9.855
10.216EMT
TO
P O
F K
ER
B
TAP TAP
MBTAPTAPMB
PROPOSED RESIDENCEGROUND FFL = 10.070
PAD RL = 9.760
CROSSOVER25m²To Local ShireCouncil requirements
PROPOSEDDRIVEWAY
45m²
DP-C DP
DPDP
DP
FENCE MOUNTEDCLOTHESLINE
97º17'25" (22.291m)
3.5m WIDEEASEMENT
9X9m C
ORNER TRUNCATIO
N
9X9m CORNER TRUNCATION
A N D E R S O N C O U R T
E A
L E
S
R
O A
D
277º17'25" (35.163m)
KE
RB
142º17'25" (9.713m)
7º17
'25"
(14
.199
m)
7º17
'25"
(15
.051
m)
22º1
7'25
" (3
.122
m)
52º1
7'25"
(3.10
6m)
82º17'25" (3.106m)
5200
WA
LL
4750 O
MP
6550
WA
LL
6100 O
MP
5200
WA
LL
4750 O
MP
4950 WALL
4500 OMP
3867
WA
LL
3417 O
MP
4509 O
MP
3476
OM
P
6284 WALL
5834 OMP
KERB
5000 MAX.
SHED STORE(6m³ Minimum)
SHED STORE(6m³ Minimum)
EXISTING TREERelocate
TO
P O
F B
AT
TE
R
TO
E O
F B
AT
TE
R
TOP OF BATTER
TOE OF BATTER
TOE OF BATTER
TOP OF BATTER
TOP OF BATTER
TOE OF BATTER
TO
P O
F B
AT
TE
R
TO
E O
F B
AT
TE
RTOP OF BATTER
TOE OF BATTER
PRIVATEOPEN SPACE -139m² TOTAL
PRINCIPALPRIVATE
OPEN SPACE4x4m - 16m²
PRINCIPALPRIVATE
OPEN SPACE4x4m - 16m²
PRIVATEOPEN SPACE -120.6m² TOTAL
FENCE MOUNTEDCLOTHESLINE
BIN STORE BIN STORE
LETTERBOX
TANDEMPARKING
4800
5400
DP-C
DPDP
FIL
L 56
0A
PP
RO
X'
CU
T 5
60A
PP
RO
X'
CU
T /
FIL
L LI
NE
CU
T 4
0
CU
T 1
40
CU
T 2
40
CU
T 3
40
CU
T 4
40
FIL
L 60
FIL
L 26
0
FIL
L 16
0
FIL
L 36
0
FIL
L 46
0
A N
D E
R S
O N
C
O U
R T
SITE TYPE E: 600m² - <900m² REQUIRED PROPOSED COMPLIANCE
Minimum Street FrontageMaximum Site CoverageMaximum Floor Area (dwellings)Maximum Floor Area (outbuildings)Maximum Floor Area(first floor balconies, decks, pergolas, etc)Maximum Building Height (dwellings)Maximum Building Height (outbuildings)Minimum Landscaped AreaMinimum Principal Private open SpaceCar Parking and Access
6.0m50%38060²12m²
8.5m4.8m30%16m² - 24m²1
35m35.1%248.52m²N / AN / A
5mN / A31.25%24m²4
YesYesYesN / AN / A
YesN / AYesYesYes
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 150
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
10028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Site Plan
1 : 150
SITE PLAN1
NOTE: STORMWATER DRAINAGE CALCULATED FOR BUILDING ROOF AREAS AND ORPAVED AREAS SHOWN ON THIS PROPOSED DEVELOPMENT ONLY, AND MAY NOT BEADEQUATE FOR ANY SUBSEQUENT ROOF OR PAVED AREAS.MIN 100x75 DOWNPIPES ( EACH TO DRAIN MAX 40.00m SQU ROOF AREA) DISCHARINGINTO 100mm S/W DRAINAGE PIPEWORK (EACH RUN CARRYING MAX CAPACITY OF 8litres/sec) MIN GRADE TO RUBBLE PITS ON SITE TO BE 1%. ALL STORMWATER & DRAINAGETO BE IN COMPLIANCE WITH BCA PARTS 3.1.2 & 3.5.2 AS WELL AS ASNZS3500
NOTE : FINAL POSITIONS OF DOWNPIPES,METERBOX, TAPS, AC ODU, WATERTANK, GASBOTTLES AND HOT WATER SYSTEM, MAYDIFFER TO PLAN DUE TO SITE CONDITIONS.
Areas
Name Area
UNIT 1 GARAGE 20.85 m²
UNIT 1 LIVING 103.49 m²
UNIT 1 PORCH 2.53 m²
UNIT 1 TERRACE 7.85 m²
UNIT 2 GARAGE 20.85 m²
UNIT 2 LIVING 103.34 m²
UNIT 2 PORCH 2.23 m²
UNIT 2 TERRACE 8.20 m²
Grand total 269.34 m²
Areas Unit 1
Name Area
UNIT 1 GARAGE 20.85 m²
UNIT 1 LIVING 103.49 m²
UNIT 1 PORCH 2.53 m²
UNIT 1 TERRACE 7.85 m²
Grand total 134.72 m²
Areas Unit 2
Name Area
UNIT 2 GARAGE 20.85 m²
UNIT 2 LIVING 103.34 m²
UNIT 2 PORCH 2.23 m²
UNIT 2 TERRACE 8.20 m²
Grand total 134.62 m²
LEGEND
DP DOWNPIPE
DP-C DOWNPIPE-COLORBOND. Colour tomatch abuttingpost/wall
MB METER BOX
TAP 12mm HOSE COCK -EXTERNAL
PROPOSED RESIDENCELOT 167SITE AREA = 708m²SITE COVERAGE = 35.1%
AREA SCHEDULE -(Excluding un-enclosed
external spaces)
UNIT 2 LIVING 103.34 m²
UNIT 2 GARAGE 20.85 m²
UNIT 1 LIVING 103.49 m²
UNIT 1 GARAGE 20.85 m²
Grand total 248.52 m²
HWS HWS
560 MH560 MH
L'DRY
GARAGE
LIVING
ENTRY
PORCH
UNIT 2
150 90 2230 220 300070
53070
2420 70 3035 160 3035 70 242070
53070
3000 220 2230 90 150
1302
2302
2124 Panel 820
DINING
820
820
820
820
820
720
720
SW1818 SW1206
SW
1809
SW
1809
SW1215
SW
1215
SW1212
2121SGD1500
1200
420
BED 1
WIR
EN'S
KITCHEN
BATHBED 3 BED 2
BRM
L'DRY
GARAGE
LIVING
ENTRY
PORCH
UNIT 1
2124 Panel820
DINING
820
820
820
820
820
720
720
SW1818SW1206
SW
1809
SW
1809
SW1215
SW
1215
SW1212
2121SGD1500
1200
420
BED 1
WIR
EN'S
KITCHEN
BATHBED 3BED 2
BRM
LINEN
2470 18990 2470
23930
220 8560 70 3035 160 3035 70 8560 220
1200 2540 70 340070
1500 70 3035 160 3035 70 150070
3400 70 2320 220 1200
1200 6230 1570 5930 1570 6230 1200
23930
1350
220
6000
70 4
707
0530
70
3000
220
220
3150
70
630
70
1100
800
2670
70
3000
220
70
1030
70 5
307
01300
220
220
1800
70
1280
70
5270
220
2830
90
150
3920
5010
3070
12000
1800
LINEN
1800
PATIOPATIO
SD
SD
MB
SD
SD
MB
70 1330 70 1620 70 70 1620 70 1330 70950 70 2015 160 2015 70 950
150 90 1330 220
150
90
1110
220 133090
150
OBS
OBS
TAP
TAP
FIR
E R
AT
ED
PA
RT
Y W
ALL
RE
FE
R D
ET
AIL
FW
FW
FW
900
VA
N
900
VA
N
WM
SK
HP+RH
DW
UBO
PTYOHC
REF
IB
900x900
900x900
FW
FW
HWD POST90x90
HWD POST90x90
DP
DP
LT
DP-C
TAP
TAP
HWD POST90x90
HWD POST90x90
DP
DP
FW
FW
FW
900
VA
N
900
VA
N
WM
SK
HP+RH
DW
UBO
PTYOHC
REF
IB
900x900
900x900
FW
LT
FW
OBS
OBS
GAS HWS GAS HWS
GASBOTTLES
GASBOTTLES
DP DP
DP-C
AC-M AC-LAC-MAC-L
1 : 100
GROUND FLOOR PLAN1
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
20028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Ground Floor
Areas
Name Area
UNIT 1 GARAGE 20.85 m²
UNIT 1 LIVING 103.49 m²
UNIT 1 PORCH 2.53 m²
UNIT 1 TERRACE 7.85 m²
UNIT 2 GARAGE 20.85 m²
UNIT 2 LIVING 103.34 m²
UNIT 2 PORCH 2.23 m²
UNIT 2 TERRACE 8.20 m²
Grand total 269.34 m²
NOTES :- FINAL POSITIONS OF DOWNPIPES, METERBOX, TAPS, AC ODU, WATERTANK, GAS BOTTLES AND HOT WATER SYSTEM, MAY DIFFER TO PLAN DUE TO SITE CONDITIONS.- LIFT OFF HINGES TO WC DOOR- SARKING TO ROOF- R1.5 INSULATION TO CEILINGS- ALL SHOWER ROSES TO BE AAA RATED- WATER PRESSURE LIMITED TO 500 KPA AT THE METER- ROOMS WITH NO NATURAL VENTILATION TO HAVE MECHANICAL VENTILATION INSTALLED- PROVIDE WATER AND POWER PROVISION TO DISHWASHER SPACE- WINDOW, SGD & INTERNAL DOOR SIZES ARE NOMINAL ONLY & TO BE CONFIRMED WITH MANUFACTURER- ARTICULATION JOINTS TO ENGINEER'S DETAIL
LEGEND
900 VAN VANITY UNIT - 900LONG
900x900 SHOWER - 900x900
AC-L AIR-CONDITIONER,Living
AC-M AIR-CONDITIONER,Master Bed
DP DOWNPIPE
DP-C DOWNPIPE-COLORBOND. Colour tomatch abuttingpost/wall
DW DISHWASHER
FW FLOOR WASTE
HP+RH HOT PLATE ANDRANGEHOOD
IB ISLAND BENCH
LT LAUNDRY TUB
MB METER BOX
OBS OBSCURE GLAZING
OHC CUPBOARD -OVERHEAD
PTY PANTRY FITOUT
REF REFRIGERATOR
SD SMOKE ALARM -IONISATION
SK SINK
TAP 12mm HOSE COCK -EXTERNAL
UBO OVEN - UNDERBENCH
WM WASHING MACHINE
PITCH 22.5°
PITCH 22.5°
PIT
CH
22.
5°
PIT
CH
22.
5°
PIT
CH
22.
5°
PITCH 22.5°
PIT
CH
22.
5°
PITCH 22.5°
DP-C
DP DP
DPDP
6284 WALL
5834 OMP
3867
WA
LL
3417 O
MP
4950 WALL
4500 OMP
4509 O
MP
5200
WA
LL
4750 O
MP
6550
WA
LL
6100 O
MP
5200
WA
LL
4750 O
MP
3476
OM
P
DP-C
DP DP
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
20228.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Roof Plan
1 : 100
ROOF PLAN1
LEGEND
DP DOWNPIPE
DP-C DOWNPIPE-COLORBOND. Colour tomatch abuttingpost/wall
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
2100 J
OIN
ER
Y
86
1500 V
EN
EE
R
O/H
450POST
600
O/H
450
VENEER
450FRAME
600
SW1809SW1809
Cs
Cs
Cbr-f
WbCbrCbr
HWD POST90x90
PITCH 22.5°
CfgCfg
NGL
SW
1215
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
2100 J
OIN
ER
Y
172
172
O/H
450
VENEER
450
POST
600
VENEER
450FRAME
600
FRAME
600
O/H
450
1500 V
EN
EE
R
CsCs
Cs
CsCs
Cfg Cfg
Wb
Cbr-f
Cbr Cbr Cbr CbrWb
Cbr-f2124 Panel820
SW1818
SW1206
2124 Panel820
SW1818
SW1206OBS OBS
HWD POST90x90
HWD POST90x90
PITCH 22.5°
NGL
POST
600
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
30028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Elevations
1 : 100
ELEVATION2
LEGEND
Cbr Common Brick,Render Finish
Cbr-f Common Brick,Render Finish,Feature Colour
Cfg Colorbond Fascia &Gutter
Cs Colorbond SteelRoofing
OBS OBSCURE GLAZING
Wb Scyon Linea Cladding
1 : 100
ELEVATION1
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
2100 J
OIN
ER
Y
1500 V
EN
EE
R
VENEER
450FRAME
600
O/H
450
O/H
450POST
600
86
SW1809 SW1809
HWD POST90x90
PITCH 22.5°
Cbr-f
Wb
Cs
Cs
Cbr CbrCfgCfg
NGL
SW
1215
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
2100 J
OIN
ER
Y
O/H
450POST
600
O/H
450POST
600
OBS OBS
86
86
SW1215SW12122121SGD
SW1215 SW12122121SGD
HWD POST90x90
PITCH 22.5°
HWD POST90x90
Cs
Cbr CbrCfgCfg
NGL
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
30128.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Elevations
1 : 100
ELEVATION4
1 : 100
ELEVATION3
LEGEND
Cbr Common Brick,Render Finish
Cbr-f Common Brick,Render Finish,Feature Colour
Cfg Colorbond Fascia &Gutter
Cs Colorbond SteelRoofing
OBS OBSCURE GLAZING
Wb Scyon Linea Cladding
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
WAFFLE POD SLABTO ENGINEERS DETAILS
22.5º PITCH TRUSSES @900CTRS TO MANUFACTURERSSPECIFICATIONS
PARTY WALL BETWEEN EACH UNITTO COMPLY WITH THE FIRE &ACOUSTICS SECTIONS OF THE BCA& MANUFACTURERS SPECIFICATIONSREFER DETAIL
GARAGELIVING DINING GARAGE LIVINGDINING
NATURAL GROUND LINEShown dashed
RLGround Floor
10.070
SFLGF Ceiling
12.510
2440 C
EIL
ING
WAFFLE POD SLABTO ENGINEERS DETAILS
22.5º PITCH TRUSSES @900CTRS TO MANUFACTURERSSPECIFICATIONS
PORCHENTRYDININGBATH
172
NATURAL GROUND LINEShown dashed
22.5º PITCHCOLORBOND ROOFING
BATTEN MAY BECONTINUOUS OVERPARTY WALL.REFER BCA
TRUSSES TOMANUFACTURERSSPECIFICATIONS
MINERAL FIBRE INSULATIONTo fill void between stud framingand roof sheeting
PARTY WALL BETWEEN EACH UNITTO COMPLY WITH THE FIRE &ACOUSTICS SECTIONS OF THE BCA& CSR SPECIFICATIONS
UNIT 1 UNIT 2
16mm GYPROCKFYRCHEK plasterboard
70mm TIMBER STUD
75 GOLD BATTS 1.5
20mm MIN CAVITYBETWEEN TIMBER STUDS
70 20 7016 16
160
PARTY WALLCSR wall system "CSR 556".FRL 60/60/60 withminimum Rw+Ctr 50.Continuous from concrete buildingslab to underside of rood sheeting,between all sole-occupancy units
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
As indicated
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
30228.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
SectionsNOTES:- SELECTED ROOF FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ROOF BATTENS FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ROOF TRUSSES TO MANUFACTURERS SPECIFICATION- BRACING OF TRUSSES TO BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ALL TIMBER SIZES TO CONFORM WITH BCA STANDARDS- SLAB & FOOTINGS TO ENGINEERS DETAIL- FLOORING MEMBERS TO ENGINEERS DETAIL
1 : 100
SECTION1
1 : 100
SECTION2
1 : 10
PARTY WALL DETAIL - "CSR 556" WALL SYSTEM3
86DN
LINE OF BRICKWORK
90x90 HWDPOST FOOTINGTO ENGRS DETAILS
90x90 HWDPOST FOOTINGTO ENGRS DETAILS
RL. 10.070 m
RL. 9.984 m
RL. 9.898 m RL. 9.898 m
RL. 9.984 m
86DN
172DN172DN
90x90 HWDPOST FOOTINGTO ENGRS DETAILS
90x90 HWDPOST FOOTINGTO ENGRS DETAILS
LINE OF BRICKWORK
LINE OF BRICKWORK
LINE OF BRICKWORK
LIN
E O
F B
RIC
KW
OR
K
LIN
E O
F B
RIC
KW
OR
K
LIN
E O
F B
RIC
KW
OR
K
LIN
E O
F B
RIC
KW
OR
K
2230 90 150150 90 2230
2470 18990 2470
23930
150
90
2830
2830
90
150
3070
5010
3920
12000
3920
5010
3070
12000
1110
90
150
1350
133090
150 15090
1330
1200 6230 1570 5930 1570 6230 1200
23930
FIR
E R
AT
ED
PA
RT
Y W
ALL
FO
OT
ING
TO
EN
GR
S D
ET
AIL
S
DOOR TRACK
DOOR PANEL
DOOR JAMB
20
20mm RECESS
10mm FALL
30
30
FALL DRIVE 1:100FOR 1000mm MIN
30mm STEP DOWN
WAFFLE POD TOENGINEERS DETAILS
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
As indicated
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
40028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Slab Layout Plan
1 : 100
SLAB LAYOUT PLAN1
1 : 10
GARAGE DOOR DETAIL2
NOTES :- EXTERNAL PATIO & PORCH SLABS TO HAVE A 1:100 FALL AWAY FROM HOUSE- SLAB & FOOTINGS TO ENGINEERS DETAIL- TERMITE TREATMENT TO BE INSTALLED AS PER MANUFACTURERS SPEC. & IN ACCORDANCE WITH AS 3660.1- ALL DIMENSIONS TO BE CHECKED AGAINST FLOOR PLAN DIMENSIONS- ALL DIMESIONS, LEVELS, HEIGHTS TO BE CONFIRMED ON SITE
HWS
HWS HWS
560 MH560 MH
NOTE* - STANDARD HEIGHTS UNLESSSTARTED OTHERWISE.- KITCHEN BENCH DGPO 1100- MICROWAVE 600- RANGEHOOD 1900- LAUNDRY 1350- BATHROOM 1200- LIGHT SWITCHES 1350- DISHWASHER 600- NBN & SGPO 1450
LIGHTING TO COMPLY WITH 40% ENERGYEFFICIENCY REQUIREMENTS
CEILING FAN
CEILING FAN/LIGHT
RECESSED DOWNLIGHT
SINGLE FLOURESCENT
WALL BUNKER LIGHT
PHONE POINT
TELEVISION POINT
EXHAUST FAN
SINGLE GPO ( 300 high)
DOUBLE GPO ( 300 high)
SINGLE GPO ( refer to notes)
DOUBLE GPO ( refer to notes)
WATERPROOF GPO
METER BOX
HOT WATER SYSTEM
NATIONAL BROADBANDNETWORK CONNECTION BOX
SMOKE ALARM
AIR-CONDITIONER
Note – Position of external items is indicative only andmay be amended to comply with relevant regulationsand/or to suit the orientation of the dwelling on the site.
UNIT 1 UNIT 2
ACC ACC
MB
SD
NBNSD
2-WAY
NBN
MB
SD
SD
2-WAY
GAS HWS GAS HWS
AC
AC
AC
AC
ACCACC
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 100
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
50028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Electrical Plan
Electrical Schedule
Name CountAIR-CONDITIONER 4
AIR-CONDITIONERCONDENSER
4
CEILING FAN 2
CEILING FAN / LIGHT 6
DOUBLE GPO 10
DOUBLE GPO (300 high) 14
HOT WATER SYSTEM 2
METER BOX 2
NBN BOX 2
PHONE POINT 4
RECESSED DOWNLIGHT 36
SINGLE FLOURESCENT 2
SINGLE GPO 8
SINGLE GPO (300 high) 2
SMOKE ALARM 4
TELEVISION POINT 4
WALL BUNKER LIGHT 4
WATERPROOF GPO SINGLE(900 AFL)
2
1 : 100
ELECTRICAL PLAN1
LEGEND
AC AIR-CONDITIONER
ACC AIR-CONDITIONERCONDENSER
MB METER BOX
NBN NATIONALBROADBANDNETWORK BOX
SD SMOKE ALARM -IONISATION
700
1
2
END PANEL
OVERHEADCUPBOARDS
DRAWERDRAWERS
200 OVERHANG
HP+RHUBO
OHC REF
SKMW DW
PTY
2400
800
1100
700
900 1500 1000
OVERHEADCUPBOARDS
OVERHEADCUPBOARDS
SLIDE OUTRANGE HOOD
END PANEL
HP+RH
UBO
PTY
DRAWERS
DRAWER
DWMW
550
650
900
340
2100
300
BENCH
OVERHEADCUPBOARDS
2440
NOBULKHEAD
FRIDGE RECESS
SHELD RECESSED20mm FROM FACEOR CUPBOARD
1800
300
340
2440
1000
END PANEL
NO BULKHEAD
Four WhiteMelamineShelves
900
2100
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
As indicated
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
70028.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Kitchen Details
1 : 20
PART FLOOR PLAN - KITCHENA
1 : 50
ELEVATION - KITCHEN1
1 : 50
ELEVATION - KITCHEN2
1 : 50
BENCH SECTION3
1 : 50
FRIDGE RECESS4
1 : 50
PANTRY DETAIL5
LEGEND
DW DISHWASHER
HP+RH HOT PLATE ANDRANGEHOOD
MW MICROWAVE SHELF
OHC CUPBOARD -OVERHEAD
PTY PANTRY FITOUT
REF REFRIGERATOR
SK SINK
UBO OVEN - UNDERBENCH
DASHED LINE INDICATES EXTENTSOF 100mm SKIRTING TILES
900x900
FW
TRH TR90
0 V
AN
FW
7011
2
3
4
DASHED LINE INDICATESEXTENTS OF 100mmSKIRTING TILES
TRH
FW
900
VA
N
900x900
FW
TR
7015
6
7
8
DASHED LINE INDICATES EXTENTSOF 100mm SKIRTING TILES
FW
LTWM
701
9
TRH
750 T
RH
2000
1000
MIR
ROR
TR
1000 T
R
1000
150
850
900
750 T
RH
TRH
TR
2000
750 T
RH
TRH
TR
2000
1000 T
R
MIR
ROR
1000
150
850
900
TRH
750 T
RH
PROVIDE NOGGINGS FORFUTURE CLOTHES DRYER
1200 1500
DWG NO:
SCALE:
DATE:
JOB NO:
ISSUE:
JOB ADDRESS:
CHECKED:DRAWN:CLIENT:
c
S.P:
PARISH:
COUNTY:
LAND AREA:
PROPERTY DETAILS
USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.
STAGED PLAN:DESIGN:
CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________
THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD
BUILDING DESIGNERSJAZZDESIGNS
1 : 50
MURPHY HOMES
LOT 167 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740
70128.04.14
14 00005
DDH BJC
BASSETT
WORKING DWG'S
CARLISLE
708m²
SP 262600RICHMOND 28 -AVALON FACADE
Wet Area Details
1 : 50
UNIT 1 PART FLOOR PLAN - BATH (UNIT 2 MIRRORED)A
1 : 50
UNIT 1 PART FLOOR PLAN - ENSUITE (UNIT 2 MIRRORED)B
1 : 50
UNIT 1 PART FLOOR PLAN - LAUNDRY (UNIT 2 MIRRORED)C
LEGEND
900 VAN VANITY UNIT - 900LONG
900x900 SHOWER - 900x900
FW FLOOR WASTE
LT LAUNDRY TUB
TR TOWEL RAIL
TRH TOILET ROLLHOLDER
WM WASHING MACHINE
1 : 50
ELEVATION1
1 : 50
ELEVATION2
1 : 50
ELEVATION3 1 : 50
ELEVATION4
1 : 50
ELEVATION5
1 : 50
ELEVATION6
1 : 50
ELEVATION7
1 : 50
ELEVATION8
1 : 50
ELEVATION9