53
Development of a Burnthrough Test Standard For Thermal Acoustic Insulation Tim Marker FAA Technical Center

Development of a Burnthrough Test Standard For Thermal

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Development of a Burnthrough Test Standard For Thermal

Development of a Burnthrough Test StandardFor Thermal Acoustic Insulation

Tim MarkerFAA Technical Center

Page 2: Development of a Burnthrough Test Standard For Thermal

Manchester 737 Accident, 1985

Page 3: Development of a Burnthrough Test Standard For Thermal

Full-Scale Testing of Surplus Aircraft

Page 4: Development of a Burnthrough Test Standard For Thermal

Burnthrough Entry Paths

Page 5: Development of a Burnthrough Test Standard For Thermal

Full-Scale Burnthrough Test Rig

Page 6: Development of a Burnthrough Test Standard For Thermal

Full-Scale Testing at FAA Tech Center

Page 7: Development of a Burnthrough Test Standard For Thermal

0

200

400

600

800

1000

1200

1400

1600

1800

2000

0 60 120 180 240 300 360 420 480 540

Time (seconds)

Tem

pera

ture

(o F)

Aluminum Skin

0.42lb/ft3 Fiberglass with Metallized PVF Film

0.42 lb/ft3 Fiberglass with Polyimide Film

Fiberglass/Ceramic Paper with Metallized PVF Film

Rigid Polyimide Foam/Ceramic/QuartzelCeramic Fibers with Polyimide Film

Oxidized Polyacrylonitrile Fiber with Polyimide Film

Full-Scale Test Results Using Various Materials

Page 8: Development of a Burnthrough Test Standard For Thermal

Laboratory Scale Test Development

Page 9: Development of a Burnthrough Test Standard For Thermal

Initial Lab-Scale Burnthrough Test Apparatus

Page 10: Development of a Burnthrough Test Standard For Thermal

Initial Lab-Scale Burnthrough Test Apparatus

Page 11: Development of a Burnthrough Test Standard For Thermal

Initial Burnthrough Testing

Page 12: Development of a Burnthrough Test Standard For Thermal

Second GenerationCurved Test Frame

Page 13: Development of a Burnthrough Test Standard For Thermal

Third Generation Framewith Aluminum Skin

Page 14: Development of a Burnthrough Test Standard For Thermal

Initial Blanket Installation Method

BurnthroughBurnthrough

Page 15: Development of a Burnthrough Test Standard For Thermal

Overlapped Installation Technique

Page 16: Development of a Burnthrough Test Standard For Thermal

Overlapped Insulation Attachment

Page 17: Development of a Burnthrough Test Standard For Thermal

Third GenerationTest Frame

Page 18: Development of a Burnthrough Test Standard For Thermal

Third Generation FrameWith 24- by 24-inch Void

Page 19: Development of a Burnthrough Test Standard For Thermal

Third Generation FrameWithout Lower Skin

Page 20: Development of a Burnthrough Test Standard For Thermal

Proposed Combination Test Rig

Page 21: Development of a Burnthrough Test Standard For Thermal

Finalized Test Frame

Page 22: Development of a Burnthrough Test Standard For Thermal

Heat Flux Measurement on Backface of Samples

Page 23: Development of a Burnthrough Test Standard For Thermal

Heat Flux Measurement on Backface of Samples

Page 24: Development of a Burnthrough Test Standard For Thermal

Finalized Test Rig

Page 25: Development of a Burnthrough Test Standard For Thermal

Typical Blanket Installation on Test Rig

Page 26: Development of a Burnthrough Test Standard For Thermal

Laboratory-Scale Test Refinements to Calibration and Test Procedures

Page 27: Development of a Burnthrough Test Standard For Thermal

Individual Calibration Rigs

Page 28: Development of a Burnthrough Test Standard For Thermal

Data Collection Procedure is Critical

Effect of Soot Buildup on Calorimeter Performance(2 minute warm-up away from calorimeter surface)

10

11

12

13

14

15

16

17

0 2 4 6 8 10 12

Time (minutes)

Hea

t Flu

x (B

tu/ft

2 sec

)

1900 ft/min2000 ft/min2100 ft/min2200 ft/min2400 ft/min2600 ft/min

Date: 11/24/99

Data Collection Period

Page 29: Development of a Burnthrough Test Standard For Thermal

Data Collection Procedure is Critical

Average Rake Temperature Vs. TimeAt Various Air Velocity Settings

1600

1700

1800

1900

2000

0 2 4 6 8 10

Time (minutes)

Tem

pera

ture

(o F)

1900 ft/min2000 ft/min2100 ft/min2200 ft/min2400 ft/min

Data Collection Period

Page 30: Development of a Burnthrough Test Standard For Thermal

Laboratory-Scale Test Refinements to Burner Equipment

Page 31: Development of a Burnthrough Test Standard For Thermal

Different Types of Stators

2 3/4” I.D. 2 5/8” I.D.

C.C.W. C.W.

4” O.D. 3 7/8” O.D.

C.W. C.W.

No Disc Disc

Page 32: Development of a Burnthrough Test Standard For Thermal

Monarch H215 Internal Stator with Static Disc

Static DiscNozzle

Page 33: Development of a Burnthrough Test Standard For Thermal

Preferred Position of Igniters to Achieve Calibration

10-11 o’clock

Page 34: Development of a Burnthrough Test Standard For Thermal

Fuel Nozzle Location

Page 35: Development of a Burnthrough Test Standard For Thermal

Laboratory-Scale TestMeasurement of Intake Air Velocity

Page 36: Development of a Burnthrough Test Standard For Thermal

Park DPL Burner Air Intake

Page 37: Development of a Burnthrough Test Standard For Thermal

Intake Airbox Holding Air Velocity Meter

Page 38: Development of a Burnthrough Test Standard For Thermal

Intake Air Velocity Measurement System

Page 39: Development of a Burnthrough Test Standard For Thermal

Primary Factors Influencing Calibration/Test Results

• Air Intake Velocity

• Fuel Flowrate

• Proper Burner Components/Adjustments(stators, position of igniters, correct fuel nozzle)

• Instrumentation (type/size of thermocouple, calorimeter type,method of collecting/reducing data)

• Fuel Temperature

• Environmental Conditions (relative humidity, barometric pressure)

Page 40: Development of a Burnthrough Test Standard For Thermal

Burner Correlation With Full-Scale Test Results

Page 41: Development of a Burnthrough Test Standard For Thermal

0

30

60

90

120

150

Failu

re T

ime

(Sec

onds

)

1:241:36

1:38

2:14

1:24 Avg

1:54 Avg

2000 ft/min 2100 ft/min 2200 ft/min

Full Scale Testsin 707

Lab Scale Tests with Burner.0

63-In

ch A

lcla

d +

3 La

yer A

eroc

or

.063

-Inch

Alc

lad

+ 4

Laye

r Aer

ocor

1:22 Avg

1:37 Avg

Correlation Using 6 GPH Burner (Full-Scale vs. Lab-Scale)

Page 42: Development of a Burnthrough Test Standard For Thermal

Round Robin Testing

Objective:

To identify and correct problems with proposed burnthrough test equipment toensure similarity between labs

Methodology:

Prove similarity of test equipment between labs through testing of identical samples

Participants:7 Domestic Labs, 3 European Labs

Status:4 round robins completed

Additional smaller round robins scheduled

Page 43: Development of a Burnthrough Test Standard For Thermal

Round Robin I Histogram

Round Robin I Material A Distribution

0

2

4

6

8

10

12

Failure Range (Seconds)

Freq

uenc

y

0-15

16-3

0

31-4

5

46-6

0

61-7

5

76-9

0

91-1

05

106-

120

121-

135

136-

150

151-

165

166-

180

181-

195

196-

210

211-

225

346-

360

Avg = 102.9

Standard Dev = 68.8

??

Page 44: Development of a Burnthrough Test Standard For Thermal

Round Robin I Material A Modified Distribution

0

2

4

6

8

10

12

Failure Range (Seconds)

Freq

uenc

y

0-15

16-3

0

31-4

5

46-6

0

61-7

5

76-9

0

91-1

05

106-

120

121-

135

136-

150

151-

165

Avg = 83.0

Standard Deviation = 28.0

Round Robin I Modified Histogram

Page 45: Development of a Burnthrough Test Standard For Thermal

Variety of Burner Components Used in Early Round Robins

Lab Code (A-J)

Internal Turbulator Rotation

Internal Turbulator

O.D. (inches)

Internal Turbulator Type

End Turbulator Rotation

End Turbulator

I.D. (inches)

End Turbulator Type

Static Disc Used (Y/N)

Tabs Used (Y/N) Nozzle Type

A CCW 4.000 Monarch H215 CW 2.75 Monarch F124 Y Y Hago 6.00B CW 4.000? Monarch 4L CW 2.75 Monarch F124 Y Y ?C N/A N/A N/A N/A N/A N/A N/A N/A N/AD CW 4.000 Monarch 4 1/2 L CW 2.75 Monarch F124 Y Y Monarch 2.00E CW 4.000 Monarch 4 1/2 L CW 2.75 Monarch F124 Y Y Monarch 6.00 80o PLPF CW 3.875 Monarch 3 7/8L CW 2.625 Monarch F124A Y Y Monarch 6.00 80o PLPG CCW 4.000 Monarch H215 CW 2.75 Monarch F124 Y Y ?H CCW 4.000 Monarch H215 CW 2.75 Monarch F124 Y Y Monarch 6.00 80o PLPI CCW 4.000 Monarch H215 CW 2.75 Monarch F124 Y Y Monarch 6.00 80o PLPJ CCW 4.000 Monarch H215 CW 2.75 Monarch F124 Y N Monarch 6.00 80o PLP

Round Robin I & II

Lab Code (A-J)

Internal Turbulator Rotation

Internal Turbulator

O.D. (inches)

Internal Turbulator Type

End Turbulator Rotation

End Turbulator

I.D. (inches)

End Turbulator Type

Static Disc Used (Y/N)

Tabs Used (Y/N) Nozzle Type

A CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLB CCW 4.000 Monarch H215* CW 2.75 Monarch F124 N N Monarch 6.00 80o PLC CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLD CCW 4.000 Monarch H215* CW 2.75 Monarch F124 N N Monarch 6.00 80o PLE CCW 4.000 Monarch H215* CW 2.75 Monarch F124 N N Monarch 6.00 80o PLF CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLG CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLH CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLI CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PLJ CCW 4.000 Monarch H215 CW 2.75 Monarch F124 N N Monarch 6.00 80o PL

Round Robin III

Page 46: Development of a Burnthrough Test Standard For Thermal

Round Robin III Histogram

0

5

10

15

20

25

30

Failure Range (Seconds)

Freq

uenc

y

1 to 10 11 to 20 21 to 30 31 to 40 41 to 50 51 to 60 61 to 70 71 to 80

Standard Deviation = 12 seconds

Average = 30 seconds

Page 47: Development of a Burnthrough Test Standard For Thermal

Round Robin IV Histogram

0

5

10

15

20

25

Failure Range (Seconds)

Freq

uenc

y

Average = 28 seconds

Standard Deviation = 8 seconds

1 to 10 11 to 20 21 to 30 31 to 40 41 to 50 51 to 60

Page 48: Development of a Burnthrough Test Standard For Thermal

0

10

20

30

40

50

60

70

80

90

100

Stan

dard

Dev

iatio

n (S

econ

ds)

RR I RR II RR III RR IV

FG (0.60 lb3/ft)

Oxidized Polyacrylonitrile

Standard Deviation Trend

Page 49: Development of a Burnthrough Test Standard For Thermal

Conclusion, Round Robins I, II, III, and IV

Decreasing standard deviation trend result of:

Standardization of Calibration and Test Procedures

Standardization of Test Burner/Apparatus

Overall Increased Familiarization with Proposed Test Method

Page 50: Development of a Burnthrough Test Standard For Thermal

Future Considerations

Conduct additional round robin test series to fully refine test method

Calibration of heat flux transducers (completed)

Calibration of air velocity meters (current)

Standardization of air velocity measurement

Conduct laboratory scale tests to investigate installation requirements

Overlap at vertical formers

Overlap at horizontal seams

Attachment Methods

Conduct full-scale confirmation tests in support of Advisory Circular

Page 51: Development of a Burnthrough Test Standard For Thermal

Blanket Overlap Testing

Page 52: Development of a Burnthrough Test Standard For Thermal

Full-Scale Overlap Testing

Page 53: Development of a Burnthrough Test Standard For Thermal

Task Group Participants

Task Group Meeting: Wednesday morning 9:00

Becky Wulliman John Brooks

Tom Tompkins Dan Trahan

Anne Mansuet Khang Tran

Steve Morgan Susahn Briggs

Hank Lutz Yo Ishikawa

Kurt Doman Alain Jacques

David Erb Bob Gardner

Jim Clyne Chad Miller