2
amdl health Digital 12-Channel ECG Machine ME 1280 Key Features 12.1 inches color TFT, 12 waveform synchronously display Portable and folding design QWERTY keyboard, multi-function shortcut keys, easy for operation Waterproof keyboard design Built-in 2GB SD Card for data storage Digital filters for better performance Baseline correction algorithm 24-bit high-resolution data sampling 1000Hz high frequency data sampling Adapt 24-bit high-accuracy data saving ensure the accuracy of follow-up data analysis

Digital 12-Channel ECG Machine ME 1280 · 2014. 5. 30. · Mediaid Inc. & AMDL Health are part of the Opto Circuits Group P/N: 51030002600 amdlhealth Contact us for support : 1800

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • amdl health

    Digital 12-Channel ECG MachineME 1280

    Key Features

    12.1 inches color TFT, 12 waveform synchronously display

    Portable and folding design

    QWERTY keyboard, multi-function shortcut keys, easy for operation

    Waterproof keyboard design

    Built-in 2GB SD Card for data storage

    Digital filters for better performance

    Baseline correction algorithm

    24-bit high-resolution data sampling

    1000Hz high frequency data sampling

    Adapt 24-bit high-accuracy data savingensure the accuracy of follow-up dataanalysis

    •••

    ••••

  • Advanced Micronic Devices Limited

    Phone: +91 80 42991800–855 Email: [email protected] Website: www.amdlcorp.comPinnacle Square, - Amarjyothi Layout, Domlur, Bengaluru 560071, India 154

    Mediaid Inc. & AMDL Health are part of the Opto Circuits Group

    P/N: 51030002600

    amdl health

    Contact us for support : 1800 103 1100

    Digital 12-Channel ECG Machine ME 1280Technical Specifications

    400mm x 330mm x 100mm (WxHxD)

    ≤7Kgs

    Measure and Diagnosis of ECG Waveform

    AC 100-240V 50/60Hz

    60VA

    Company with IEC 60601-1 and IEC 60601-1-2

    12.1” Color TFT

    800x600 pixels

    Rechargeable Lithium battery, 11.1V/4.0AH

    Used continuously for 3/1.5 hours, print 400/200

    shares of cardiogram

    Yes

    HR range

    HR precision

    Coefficient Error

    Measure info of ECG waveform

    Diagnosis analyze

    30bpm-350bpm

    ±1bpm (10s average)

    ≤ 5%, 0.333P time limit, PR interphase, QRS time limit, QT

    interphase, QTC interphase, RR iterphase, RV5swing,

    SV1swing, RV6swing, SV2swing, RV5+SV1swing, Paxis,

    QRSaxis

    ≥ 140 types

    Size and Weight

    Size

    Weight

    Power Supply

    Power Voltage

    Input Current

    Standard

    Display

    Type

    Resolution

    Battery

    Type

    Operating time

    Indication of battery

    capability

    Thermal dot array

    40dots/mm

    40dots/mm

    5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s,

    50mm/s, error: ±3%

    ≤ 0.5mm/30M295mm/280mm

    210mm/216mm

    Folded thermo sensitive printing paper

    Real thermo sensitive printing paper

    More than 10 kind of printing methods

    (3x4, 3x4+1R, 3x4+3R, 6x2, 6x2+1R, 12x1 Manual 3path,

    Manual 6path, Manual 12path, single-lead rhythm,

    three-leads rhythm and so on)

    Recorder

    Recording way

    Horizontal resolution

    Vertical resolution

    Recording speed

    Recording linearity

    Paper length

    Paper width

    Paper type

    Recording type

    100groups of ECG data

    SD card or U disk

    Background storage automatically

    xml

    Data Storage

    Fixed Memory

    Optional Memory

    Storage mode

    Storage format

    Standard PC 104 (position)

    1xRJ-45 socket

    2 x USB Host (support hot-swap)

    1 x Standard SD cad socket

    Input/Output Specification

    Touch screen option

    Keyboard

    Network connector

    USB connector

    SD card

    12-lead, defibrilator-proof, Pacemaker pulse rejection

    4000V, Type CF applied part

    ≥ ±500mv0.05Hz-150Hz(-3dB)

    0.05Hz, 0.15Hz, 0.25Hz, 0.5Hz

    25Hz, 35Hz, 45Hz

    75Hz, 100Hz, 150Hz

    2.5, 5, 10, 20, 10/5, AGC(mm/mv)

    ±5%

    5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s,

    50mm/s

    ≥50MΩ≤ 50nA≤ 10µA≥109db (with AC filter)

    ≤5s

    ≤1s5000V 360J

    ≤5s

    ≤10s≤10%≤1VIEC 60601-2-51

    Display of ECG Collection

    Signal input

    Degree of protection against

    electric shock

    Polarization voltage resistance

    Response to frequency

    Baseline filter

    ECG filter

    Lowpass filter

    Gain selection

    Gain accuracy

    Time base selection

    Input impedance

    Current of input loop

    Patient leakage current

    CMRR

    Time for response to wave

    displaying

    Time for baseline recovered

    after switching leads

    Defibrilator - proof

    Recovering time for

    defibrilator-proof

    Recovering time for defibrilator

    electrode polarization

    Energy reduced

    Voltage transfer

    Standard complied with

    5~40° C

    25% ~ 93% (non condensing)

    700~1060 hPa

    Environmental Specifications

    Operating temperature

    Relative humidity

    Atmospheric Pressure

    -20~+55

    25%~95% (non condensing)

    500~1060 hPa

    ° C

    Transportation and Storage

    Temperature

    Relative humidity

    Atmospheric Pressure

    Page 1Page 2