Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
amdl health
Digital 12-Channel ECG MachineME 1280
Key Features
12.1 inches color TFT, 12 waveform synchronously display
Portable and folding design
QWERTY keyboard, multi-function shortcut keys, easy for operation
Waterproof keyboard design
Built-in 2GB SD Card for data storage
Digital filters for better performance
Baseline correction algorithm
24-bit high-resolution data sampling
1000Hz high frequency data sampling
Adapt 24-bit high-accuracy data savingensure the accuracy of follow-up dataanalysis
•
•
•••
•
••••
Advanced Micronic Devices Limited
Phone: +91 80 42991800–855 Email: [email protected] Website: www.amdlcorp.comPinnacle Square, - Amarjyothi Layout, Domlur, Bengaluru 560071, India 154
Mediaid Inc. & AMDL Health are part of the Opto Circuits Group
P/N: 51030002600
amdl health
Contact us for support : 1800 103 1100
Digital 12-Channel ECG Machine ME 1280Technical Specifications
400mm x 330mm x 100mm (WxHxD)
≤7Kgs
Measure and Diagnosis of ECG Waveform
AC 100-240V 50/60Hz
60VA
Company with IEC 60601-1 and IEC 60601-1-2
12.1” Color TFT
800x600 pixels
Rechargeable Lithium battery, 11.1V/4.0AH
Used continuously for 3/1.5 hours, print 400/200
shares of cardiogram
Yes
HR range
HR precision
Coefficient Error
Measure info of ECG waveform
Diagnosis analyze
30bpm-350bpm
±1bpm (10s average)
≤ 5%, 0.333P time limit, PR interphase, QRS time limit, QT
interphase, QTC interphase, RR iterphase, RV5swing,
SV1swing, RV6swing, SV2swing, RV5+SV1swing, Paxis,
QRSaxis
≥ 140 types
Size and Weight
Size
Weight
Power Supply
Power Voltage
Input Current
Standard
Display
Type
Resolution
Battery
Type
Operating time
Indication of battery
capability
Thermal dot array
40dots/mm
40dots/mm
5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s,
50mm/s, error: ±3%
≤ 0.5mm/30M295mm/280mm
210mm/216mm
Folded thermo sensitive printing paper
Real thermo sensitive printing paper
More than 10 kind of printing methods
(3x4, 3x4+1R, 3x4+3R, 6x2, 6x2+1R, 12x1 Manual 3path,
Manual 6path, Manual 12path, single-lead rhythm,
three-leads rhythm and so on)
Recorder
Recording way
Horizontal resolution
Vertical resolution
Recording speed
Recording linearity
Paper length
Paper width
Paper type
Recording type
100groups of ECG data
SD card or U disk
Background storage automatically
xml
Data Storage
Fixed Memory
Optional Memory
Storage mode
Storage format
Standard PC 104 (position)
1xRJ-45 socket
2 x USB Host (support hot-swap)
1 x Standard SD cad socket
Input/Output Specification
Touch screen option
Keyboard
Network connector
USB connector
SD card
12-lead, defibrilator-proof, Pacemaker pulse rejection
4000V, Type CF applied part
≥ ±500mv0.05Hz-150Hz(-3dB)
0.05Hz, 0.15Hz, 0.25Hz, 0.5Hz
25Hz, 35Hz, 45Hz
75Hz, 100Hz, 150Hz
2.5, 5, 10, 20, 10/5, AGC(mm/mv)
±5%
5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s,
50mm/s
≥50MΩ≤ 50nA≤ 10µA≥109db (with AC filter)
≤5s
≤1s5000V 360J
≤5s
≤10s≤10%≤1VIEC 60601-2-51
Display of ECG Collection
Signal input
Degree of protection against
electric shock
Polarization voltage resistance
Response to frequency
Baseline filter
ECG filter
Lowpass filter
Gain selection
Gain accuracy
Time base selection
Input impedance
Current of input loop
Patient leakage current
CMRR
Time for response to wave
displaying
Time for baseline recovered
after switching leads
Defibrilator - proof
Recovering time for
defibrilator-proof
Recovering time for defibrilator
electrode polarization
Energy reduced
Voltage transfer
Standard complied with
5~40° C
25% ~ 93% (non condensing)
700~1060 hPa
Environmental Specifications
Operating temperature
Relative humidity
Atmospheric Pressure
-20~+55
25%~95% (non condensing)
500~1060 hPa
° C
Transportation and Storage
Temperature
Relative humidity
Atmospheric Pressure
Page 1Page 2