8
Digital Implant No.1 Abutment Digital

Digital Abutment · 2019. 6. 28. · Digital Abutment Product Catalog Digital Abutment 06 07 Pre-Molar UF(II) Angled Abutment_Hex No. Code Cuff Post Marking 1 DPR 1540H 1.5 4.0 P14

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

  • Digital Implant No.1

    AbutmentDigital

  • Digital Abutment Product Catalog Digital Abutment

    02 03

    MORE developed thanthe Ready-made Abutments, MORE convenient thanthe Customized Abutments!

    CEJ Cemento Enamel junctionDigital abutment was created based on the CEJ therefore has excellent esthetic appearance, and is healed more similar to a natural teeth due to its induction to sufficient gingiva adhesion.

    Maxillary

    Mandible

    Molar

    Premolar

    CanineIncisor

    Molar

    Prem

    olar

    Canin

    eInciso

    r

    A Clinical Application Example of Digital Abutment

    An Abutment optimized for Immediate Loading during Flapless Surgery Modification possible during immediate loading even if the height of gingiva changes The convenience of not needing to detach the abutment up to the Final prosthetic placement after the Implant Surgery The possibility of Double Crown Technique in the case of Full mouth Flapless Surgery, within the range of errors

    Prosthetic production process using Digital Abutment in DIOnavi Surgery

  • Digital Abutment Product Catalog Digital Abutment

    02 03

    Lower Incisor Upper Incisor Canine Pre-Molar Molar

    Cross Section

    Cervical MarginCross Section

    Facial Side

    Connection UF(II) Narrow UF(II) Narrow / UF(II) UF(II) UF(II) UF(II)

    Cervical Margin Dimension (Mesiodistal x faciolingual)

    5 X 5.2 6.1 X 5.7 5.3 X 6.3 5.8 X 6.8 7.3 X 7.8

    Ratio (%) 70% 70% / 85% 85% 85% 85%

    단면

    치경부단면

    디지털어버트먼트

    LowerIncisor하악전치

    UpperIncisor상악전치

    Canine견치

    Pre-Molar소구치칯

    Molar대구치

    L25

    U25 C25

    P25

    M25

    단면

    치경부단면

    디지털어버트먼트

    LowerIncisor하악전치

    UpperIncisor상악전치

    Canine견치

    Pre-Molar소구치칯

    Molar대구치

    L25

    U25 C25

    P25

    M25

    단면

    치경부단면

    디지털어버트먼트

    LowerIncisor하악전치

    UpperIncisor상악전치

    Canine견치

    Pre-Molar소구치칯

    Molar대구치

    L25

    U25 C25

    P25

    M25

    단면

    치경부단면

    디지털어버트먼트

    LowerIncisor하악전치

    UpperIncisor상악전치

    Canine견치

    Pre-Molar소구치칯

    Molar대구치

    L25

    U25 C25

    P25

    M25

    단면

    치경부단면

    디지털어버트먼트

    LowerIncisor하악전치

    UpperIncisor상악전치

    Canine견치

    Pre-Molar소구치칯

    Molar대구치

    L25

    U25 C25

    P25

    M25

    Scan Adapter Function

    Protect Cap Lock-Groove

    Marking

    UF(II) Connection

    Shoulder Margin

    L25 · L Lower Incisor 2 Cuff Height 5 Post HeightU25 · U Upper Incisor 2 Cuff Height 5 Post HeightC25 · C Canine 2 Cuff Height 5 Post HeightP25 · P Pre-Molar 2 Cuff Height 5 Post HeightM25 · M Molar 2 Cuff Height 5 Post Height

    Attention

    0.5 unit marking exempted in accordance with marketingex) Cuff 2.5 = 2 / Post 5.5 = 5

    UF(II) NarrowConnection

    UF(II)Connection

  • Digital Abutment Product Catalog Digital Abutment

    04 05

    Lower Incisor

    Upper Incisor

    UF(II) Narrow Angled Abutment_Hex

    UF(II) Narrow Angled Abutment_Hex

    UF(II) Narrow Protect Cap

    UF(II) Narrow Protect Cap

    No. Code Cuff Post Marking

    1 DLN 2555H 2.5

    5.5

    L252 DLN 3555H 3.5 L353 DLN 4555H 4.5 L454 DLN 5555H 5.5 L555 DLN 2570H 2.5

    7.0

    L276 DLN 3570H 3.5 L377 DLN 4570H 4.5 L478 DLN 5570H 5.5 L57

    No. Code Cuff Post Marking

    1 DUN 2555H 2.5

    5.5

    U252 DUN 3555H 3.5 U353 DUN 4555H 4.5 U454 DUN 5555H 5.5 U555 DUN 2570H 2.5

    7.0

    U276 DUN 3570H 3.5 U377 DUN 4570H 4.5 U478 DUN 5570H 5.5 U57

    No. Code Post

    9 DCLN 55 5.510 DCLN 70 7.0

    No. Code Post

    9 DCUN 55 5.510 DCUN 70 7.0

    UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H

    UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H

    Post

    (5.5

    )Po

    st (5

    .5)

    Post

    (7)

    Post

    (7)

    Cuff

    Cuff

    Cuff

    Cuff

    3.47

    3.64

    4.13

    3.99

    UF(II) Narrow Screw

    UF(II) Narrow Screw

    D

    C

    Hex Non-Hex

    D

    C

    L

    Hex Non-Hex

    FixtureLevel

    FixtureLevel

    Drill

    33 / 8.5

    33 / 10

    33 / 11.5

    33 / 13

    L1 / L2 Dia.

    DSU 2708M

    DSU 2710M

    DSU 2711M

    DSU 2713M

    Ø2.7L1 / L2

    Starter Drill

    30 / 15

    Dia.

    SD 1530M

    Ø1.5 L1 / L2

    Initial Drill

    34.5 / 17.5

    Dia.

    DHF 2015SM

    Ø2.0

    8.57

    DSU

    2708

    M

    L2

    0.5

    L1

    D

    DSU

    27xx

    M

    L1 / L2

    Parallel PinD1 / D2 Ø2.0 / Ø2.7

    22/10 PP 2022

    PP 202323/16

    1.2 Hex Screw Driver

    16

    20

    Length Type Machine Ratchet

    -

    -

    MD 1230

    HD 1220A

    L

    L

    L2

    L1

    D

    L2

    0.5

    L1

    D

    Ø2.0

    78.5

    1011.5

    1315

    L1

    L2

    D1

    D2

    Hex 1.2

    C

    Apex Apex

    Hex 1.7 Hex 1.7

    L

    Ø3.3Ø3.0

    FixtureLevel

    DHex 1.2

    C

    Diameter

    Cuff/Height

    H

    0.5Ø4.2

    C6H10

    FixtureLevel

    C

    L

    Hex Non-Hex

    D

    FixtureLevel

    C

    15°

    Hex Non-Hex

    D

    FixtureLevel

    C

    L

    FixtureLevel

    Hex Non-Hex

    D

    L

    D

    Tap Drill

    Code

    Diameter

    UNTD 3015 UNTD 3315

    Ø3.0 Ø3.3

    Fixture Driver

    6

    12

    18

    Length Type Machine Ratchet

    Diameter

    UNFDC 3006

    UNFDC 3012

    UNFDC 3018

    UNFDW 3006

    UNFDW 3012

    UNFDW 3018

    Ø3.0 / Ø3.3

    Option) Available(별매품)

    L

    L

    L

    D

    D

    D

    CFixtureLevel

    D

    Torque Wrench

    *Bottom Case

    DTW 0060

    8.5 / 10 / 11.5 / 13 / 15 / 18

    Depth Gauge DPG 2050

    D

    D

    C

    L

    FixtureLevel

    1.2 Hex

    L

    D

    L

    D

    L

    D

    L2

    L1

    D

    L2

    0.5

    L1

    D

    Ø2.0

    78.5

    1011.5

    1315

    L1

    L2

    D1

    D2

    8.57

    DSU

    2708

    M

    L2

    0.5

    L1

    D

    DSU

    27xx

    M

    L

    L

    D

    C

    Hex Non-Hex

    D

    C

    L

    Hex Non-Hex

    FixtureLevel

    FixtureLevel

    Drill

    33 / 8.5

    33 / 10

    33 / 11.5

    33 / 13

    L1 / L2 Dia.

    DSU 2708M

    DSU 2710M

    DSU 2711M

    DSU 2713M

    Ø2.7L1 / L2

    Starter Drill

    30 / 15

    Dia.

    SD 1530M

    Ø1.5 L1 / L2

    Initial Drill

    34.5 / 17.5

    Dia.

    DHF 2015SM

    Ø2.0

    8.57

    DSU

    2708

    M

    L2

    0.5

    L1

    D

    DSU

    27xx

    M

    L1 / L2

    Parallel PinD1 / D2 Ø2.0 / Ø2.7

    22/10 PP 2022

    PP 202323/16

    1.2 Hex Screw Driver

    16

    20

    Length Type Machine Ratchet

    -

    -

    MD 1230

    HD 1220A

    L

    L

    L2

    L1

    D

    L2

    0.5

    L1

    D

    Ø2.0

    78.5

    1011.5

    1315

    L1

    L2

    D1

    D2

    Hex 1.2

    C

    Apex Apex

    Hex 1.7 Hex 1.7

    L

    Ø3.3Ø3.0

    FixtureLevel

    DHex 1.2

    C

    Diameter

    Cuff/Height

    H

    0.5Ø4.2

    C6H10

    FixtureLevel

    C

    L

    Hex Non-Hex

    D

    FixtureLevel

    C

    15°

    Hex Non-Hex

    D

    FixtureLevel

    C

    L

    FixtureLevel

    Hex Non-Hex

    D

    L

    D

    Tap Drill

    Code

    Diameter

    UNTD 3015 UNTD 3315

    Ø3.0 Ø3.3

    Fixture Driver

    6

    12

    18

    Length Type Machine Ratchet

    Diameter

    UNFDC 3006

    UNFDC 3012

    UNFDC 3018

    UNFDW 3006

    UNFDW 3012

    UNFDW 3018

    Ø3.0 / Ø3.3

    Option) Available(별매품)

    L

    L

    L

    D

    D

    D

    CFixtureLevel

    D

    Torque Wrench

    *Bottom Case

    DTW 0060

    8.5 / 10 / 11.5 / 13 / 15 / 18

    Depth Gauge DPG 2050

    D

    D

    C

    L

    FixtureLevel

    1.2 Hex

    L

    D

    L

    D

    L

    D

    L2

    L1

    D

    L2

    0.5

    L1

    D

    Ø2.0

    78.5

    1011.5

    1315

    L1

    L2

    D1

    D2

    8.57

    DSU

    2708

    M

    L2

    0.5

    L1

    D

    DSU

    27xx

    M

    L

    L

  • Digital Abutment Product Catalog Digital Abutment

    04 05

    Upper Incisor

    Canine

    UF(II) Angled Abutment_Hex

    UF(II) Protect Cap

    No. Code Cuff Post Marking

    1 DUR 2555H 2.5

    5.5

    U252 DUR 3555H 3.5 U353 DUR 4555H 4.5 U454 DUR 5555H 5.5 U555 DUR 2570H 2.5

    7.0

    U276 DUR 3570H 3.5 U377 DUR 4570H 4.5 U478 DUR 5570H 5.5 U57

    UF(II) Angled Abutment_HexNo. Code Cuff Post Marking

    1 DCR 2555H 2.55.5

    C252 DCR 3555H 3.5 C353 DCR 2570H 2.5

    7.0C45

    4 DCR 3570H 3.5 C55

    No. Code Post

    9 DCUR 55 5.510 DCUR 70 7.0

    UF(II) Protect CapNo. Code Post

    9 DCCR 55 5.510 DCCR 70 7.0

    Post

    (5.5

    )Po

    st (7

    )Cu

    ffPo

    st (5

    .5)

    Cuff

    Cuff

    Post

    (7)

    Cuff 4.49

    5.27

    5.11

    4.85

    UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

    UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

  • Digital Abutment Product Catalog Digital Abutment

    06 07

    Pre-MolarUF(II) Angled Abutment_Hex

    No. Code Cuff Post Marking

    1 DPR 1540H 1.5

    4.0

    P142 DPR 2540H 2.5 P243 DPR 3540H 3.5 P344 DPR 4540H 4.5 P445 DPR 1555H 1.5

    5.5

    P156 DPR 2555H 2.5 P257 DPR 3555H 3.5 P358 DPR 4555H 4.5 P45

    UF(II) Protect CapNo. Code Post

    9 DCPR 40 4.010 DCPR 55 5.5

    MolarUF(II) Angled Abutment_Hex

    No. Code Cuff Post Marking

    1 DMR 1540H 1.5

    4.0

    M142 DMR 2540H 2.5 M243 DMR 3540H 3.5 M344 DMR 4540H 4.5 M445 DMR 1555H 1.5

    5.5

    M156 DMR 2555H 2.5 M257 DMR 3555H 3.5 M358 DMR 4555H 4.5 M45

    UF(II) Protect CapNo. Code Post

    9 DCMR 40 4.010 DCMR 55 5.5

    Post

    (4.0

    )Po

    st (4

    .0)

    Post

    (5.5

    )Po

    st (5

    .5)

    Cuff

    Cuff

    Cuff

    Cuff

    6.29

    6.14

    5.78

    4.84

    UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

    UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

  • Digital Abutment Product Catalog Digital Abutment

    06 07

    The Advantages of Digital Abutment

    Digital Abutment Workflow

    In the case of Immediate Loading, it is possible to instantly choose the abutment based on the patients’ oral environment.

    The prosthetic production time for the Digital Abutment is reduced because it doesn’t need to go through the Milling and CAD process due to its data in the Digital Library.

    Taking the Digital Impression is very convenient for the Digital Abutment because it functions as a Scan adaptor and there is no need to take the exact impression up to the margin because its’ data is stored in the Digital Library.

    DIOnavi.

    Scanning

    Image taking

    Image taking

    Implant Planning

    Matching Software

    Production

    1) CT shooting2) Trios or Plaster model scan

    1) Implant Procedure2) Digital Abutment Placement3) Trios or Plaster model scan

    1) CT and Trios Scan Data matching2) Provisional crown design3) Implant planning4) Guide stent design

    1) Trios Scan data and Digital Abutment Library Matching2) Crown Design3) Prosthetic Production

    1) Guide stent production2) Digital Abutment Library Matching3) Provisional crown Production (Abutment JIG)

    T IP

    In the case where the fixture implantation depth does not match the planning depth due to change of operation environment during surgery- It is possible to choose the different height cuffs of Digital Abutment.- The provisional Crown that is custom fitted to the DA can be used as it is even if the cuff changes and it can be modified on the field but if there is too much height difference, it should be remanufactured.- If not using the Provisional crown, healing can be induced by attaching a protect cap.

  • DIO Implant 66, Centum seo-ro, Haeundae-gu, Busan 612-020, Korea Tel +82 51 745 7777 Fax +82 51 745 7778 www.dioimplant.com