Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
Digital Implant No.1
AbutmentDigital
Digital Abutment Product Catalog Digital Abutment
02 03
MORE developed thanthe Ready-made Abutments, MORE convenient thanthe Customized Abutments!
CEJ Cemento Enamel junctionDigital abutment was created based on the CEJ therefore has excellent esthetic appearance, and is healed more similar to a natural teeth due to its induction to sufficient gingiva adhesion.
Maxillary
Mandible
Molar
Premolar
CanineIncisor
Molar
Prem
olar
Canin
eInciso
r
A Clinical Application Example of Digital Abutment
An Abutment optimized for Immediate Loading during Flapless Surgery Modification possible during immediate loading even if the height of gingiva changes The convenience of not needing to detach the abutment up to the Final prosthetic placement after the Implant Surgery The possibility of Double Crown Technique in the case of Full mouth Flapless Surgery, within the range of errors
Prosthetic production process using Digital Abutment in DIOnavi Surgery
Digital Abutment Product Catalog Digital Abutment
02 03
Lower Incisor Upper Incisor Canine Pre-Molar Molar
Cross Section
Cervical MarginCross Section
Facial Side
Connection UF(II) Narrow UF(II) Narrow / UF(II) UF(II) UF(II) UF(II)
Cervical Margin Dimension (Mesiodistal x faciolingual)
5 X 5.2 6.1 X 5.7 5.3 X 6.3 5.8 X 6.8 7.3 X 7.8
Ratio (%) 70% 70% / 85% 85% 85% 85%
단면
치경부단면
디지털어버트먼트
LowerIncisor하악전치
UpperIncisor상악전치
Canine견치
Pre-Molar소구치칯
Molar대구치
L25
U25 C25
P25
M25
단면
치경부단면
디지털어버트먼트
LowerIncisor하악전치
UpperIncisor상악전치
Canine견치
Pre-Molar소구치칯
Molar대구치
L25
U25 C25
P25
M25
단면
치경부단면
디지털어버트먼트
LowerIncisor하악전치
UpperIncisor상악전치
Canine견치
Pre-Molar소구치칯
Molar대구치
L25
U25 C25
P25
M25
단면
치경부단면
디지털어버트먼트
LowerIncisor하악전치
UpperIncisor상악전치
Canine견치
Pre-Molar소구치칯
Molar대구치
L25
U25 C25
P25
M25
단면
치경부단면
디지털어버트먼트
LowerIncisor하악전치
UpperIncisor상악전치
Canine견치
Pre-Molar소구치칯
Molar대구치
L25
U25 C25
P25
M25
Scan Adapter Function
Protect Cap Lock-Groove
Marking
UF(II) Connection
Shoulder Margin
L25 · L Lower Incisor 2 Cuff Height 5 Post HeightU25 · U Upper Incisor 2 Cuff Height 5 Post HeightC25 · C Canine 2 Cuff Height 5 Post HeightP25 · P Pre-Molar 2 Cuff Height 5 Post HeightM25 · M Molar 2 Cuff Height 5 Post Height
Attention
0.5 unit marking exempted in accordance with marketingex) Cuff 2.5 = 2 / Post 5.5 = 5
UF(II) NarrowConnection
UF(II)Connection
Digital Abutment Product Catalog Digital Abutment
04 05
Lower Incisor
Upper Incisor
UF(II) Narrow Angled Abutment_Hex
UF(II) Narrow Angled Abutment_Hex
UF(II) Narrow Protect Cap
UF(II) Narrow Protect Cap
No. Code Cuff Post Marking
1 DLN 2555H 2.5
5.5
L252 DLN 3555H 3.5 L353 DLN 4555H 4.5 L454 DLN 5555H 5.5 L555 DLN 2570H 2.5
7.0
L276 DLN 3570H 3.5 L377 DLN 4570H 4.5 L478 DLN 5570H 5.5 L57
No. Code Cuff Post Marking
1 DUN 2555H 2.5
5.5
U252 DUN 3555H 3.5 U353 DUN 4555H 4.5 U454 DUN 5555H 5.5 U555 DUN 2570H 2.5
7.0
U276 DUN 3570H 3.5 U377 DUN 4570H 4.5 U478 DUN 5570H 5.5 U57
No. Code Post
9 DCLN 55 5.510 DCLN 70 7.0
No. Code Post
9 DCUN 55 5.510 DCUN 70 7.0
UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H
UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H
Post
(5.5
)Po
st (5
.5)
Post
(7)
Post
(7)
Cuff
Cuff
Cuff
Cuff
3.47
3.64
4.13
3.99
UF(II) Narrow Screw
UF(II) Narrow Screw
D
C
Hex Non-Hex
D
C
L
Hex Non-Hex
FixtureLevel
FixtureLevel
Drill
33 / 8.5
33 / 10
33 / 11.5
33 / 13
L1 / L2 Dia.
DSU 2708M
DSU 2710M
DSU 2711M
DSU 2713M
Ø2.7L1 / L2
Starter Drill
30 / 15
Dia.
SD 1530M
Ø1.5 L1 / L2
Initial Drill
34.5 / 17.5
Dia.
DHF 2015SM
Ø2.0
8.57
DSU
2708
M
L2
0.5
L1
D
DSU
27xx
M
L1 / L2
Parallel PinD1 / D2 Ø2.0 / Ø2.7
22/10 PP 2022
PP 202323/16
1.2 Hex Screw Driver
16
20
Length Type Machine Ratchet
-
-
MD 1230
HD 1220A
L
L
L2
L1
D
L2
0.5
L1
D
Ø2.0
78.5
1011.5
1315
L1
L2
D1
D2
Hex 1.2
C
Apex Apex
Hex 1.7 Hex 1.7
L
Ø3.3Ø3.0
FixtureLevel
DHex 1.2
C
Diameter
Cuff/Height
H
0.5Ø4.2
C6H10
FixtureLevel
C
L
Hex Non-Hex
D
FixtureLevel
C
15°
Hex Non-Hex
D
FixtureLevel
C
L
FixtureLevel
Hex Non-Hex
D
L
D
Tap Drill
Code
Diameter
UNTD 3015 UNTD 3315
Ø3.0 Ø3.3
Fixture Driver
6
12
18
Length Type Machine Ratchet
Diameter
UNFDC 3006
UNFDC 3012
UNFDC 3018
UNFDW 3006
UNFDW 3012
UNFDW 3018
Ø3.0 / Ø3.3
Option) Available(별매품)
L
L
L
D
D
D
CFixtureLevel
D
Torque Wrench
*Bottom Case
DTW 0060
8.5 / 10 / 11.5 / 13 / 15 / 18
Depth Gauge DPG 2050
D
D
C
L
FixtureLevel
1.2 Hex
L
D
L
D
L
D
L2
L1
D
L2
0.5
L1
D
Ø2.0
78.5
1011.5
1315
L1
L2
D1
D2
8.57
DSU
2708
M
L2
0.5
L1
D
DSU
27xx
M
L
L
D
C
Hex Non-Hex
D
C
L
Hex Non-Hex
FixtureLevel
FixtureLevel
Drill
33 / 8.5
33 / 10
33 / 11.5
33 / 13
L1 / L2 Dia.
DSU 2708M
DSU 2710M
DSU 2711M
DSU 2713M
Ø2.7L1 / L2
Starter Drill
30 / 15
Dia.
SD 1530M
Ø1.5 L1 / L2
Initial Drill
34.5 / 17.5
Dia.
DHF 2015SM
Ø2.0
8.57
DSU
2708
M
L2
0.5
L1
D
DSU
27xx
M
L1 / L2
Parallel PinD1 / D2 Ø2.0 / Ø2.7
22/10 PP 2022
PP 202323/16
1.2 Hex Screw Driver
16
20
Length Type Machine Ratchet
-
-
MD 1230
HD 1220A
L
L
L2
L1
D
L2
0.5
L1
D
Ø2.0
78.5
1011.5
1315
L1
L2
D1
D2
Hex 1.2
C
Apex Apex
Hex 1.7 Hex 1.7
L
Ø3.3Ø3.0
FixtureLevel
DHex 1.2
C
Diameter
Cuff/Height
H
0.5Ø4.2
C6H10
FixtureLevel
C
L
Hex Non-Hex
D
FixtureLevel
C
15°
Hex Non-Hex
D
FixtureLevel
C
L
FixtureLevel
Hex Non-Hex
D
L
D
Tap Drill
Code
Diameter
UNTD 3015 UNTD 3315
Ø3.0 Ø3.3
Fixture Driver
6
12
18
Length Type Machine Ratchet
Diameter
UNFDC 3006
UNFDC 3012
UNFDC 3018
UNFDW 3006
UNFDW 3012
UNFDW 3018
Ø3.0 / Ø3.3
Option) Available(별매품)
L
L
L
D
D
D
CFixtureLevel
D
Torque Wrench
*Bottom Case
DTW 0060
8.5 / 10 / 11.5 / 13 / 15 / 18
Depth Gauge DPG 2050
D
D
C
L
FixtureLevel
1.2 Hex
L
D
L
D
L
D
L2
L1
D
L2
0.5
L1
D
Ø2.0
78.5
1011.5
1315
L1
L2
D1
D2
8.57
DSU
2708
M
L2
0.5
L1
D
DSU
27xx
M
L
L
Digital Abutment Product Catalog Digital Abutment
04 05
Upper Incisor
Canine
UF(II) Angled Abutment_Hex
UF(II) Protect Cap
No. Code Cuff Post Marking
1 DUR 2555H 2.5
5.5
U252 DUR 3555H 3.5 U353 DUR 4555H 4.5 U454 DUR 5555H 5.5 U555 DUR 2570H 2.5
7.0
U276 DUR 3570H 3.5 U377 DUR 4570H 4.5 U478 DUR 5570H 5.5 U57
UF(II) Angled Abutment_HexNo. Code Cuff Post Marking
1 DCR 2555H 2.55.5
C252 DCR 3555H 3.5 C353 DCR 2570H 2.5
7.0C45
4 DCR 3570H 3.5 C55
No. Code Post
9 DCUR 55 5.510 DCUR 70 7.0
UF(II) Protect CapNo. Code Post
9 DCCR 55 5.510 DCCR 70 7.0
Post
(5.5
)Po
st (7
)Cu
ffPo
st (5
.5)
Cuff
Cuff
Post
(7)
Cuff 4.49
5.27
5.11
4.85
UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.
UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.
Digital Abutment Product Catalog Digital Abutment
06 07
Pre-MolarUF(II) Angled Abutment_Hex
No. Code Cuff Post Marking
1 DPR 1540H 1.5
4.0
P142 DPR 2540H 2.5 P243 DPR 3540H 3.5 P344 DPR 4540H 4.5 P445 DPR 1555H 1.5
5.5
P156 DPR 2555H 2.5 P257 DPR 3555H 3.5 P358 DPR 4555H 4.5 P45
UF(II) Protect CapNo. Code Post
9 DCPR 40 4.010 DCPR 55 5.5
MolarUF(II) Angled Abutment_Hex
No. Code Cuff Post Marking
1 DMR 1540H 1.5
4.0
M142 DMR 2540H 2.5 M243 DMR 3540H 3.5 M344 DMR 4540H 4.5 M445 DMR 1555H 1.5
5.5
M156 DMR 2555H 2.5 M257 DMR 3555H 3.5 M358 DMR 4555H 4.5 M45
UF(II) Protect CapNo. Code Post
9 DCMR 40 4.010 DCMR 55 5.5
Post
(4.0
)Po
st (4
.0)
Post
(5.5
)Po
st (5
.5)
Cuff
Cuff
Cuff
Cuff
6.29
6.14
5.78
4.84
UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.
UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.
Digital Abutment Product Catalog Digital Abutment
06 07
The Advantages of Digital Abutment
Digital Abutment Workflow
In the case of Immediate Loading, it is possible to instantly choose the abutment based on the patients’ oral environment.
The prosthetic production time for the Digital Abutment is reduced because it doesn’t need to go through the Milling and CAD process due to its data in the Digital Library.
Taking the Digital Impression is very convenient for the Digital Abutment because it functions as a Scan adaptor and there is no need to take the exact impression up to the margin because its’ data is stored in the Digital Library.
DIOnavi.
Scanning
Image taking
Image taking
Implant Planning
Matching Software
Production
1) CT shooting2) Trios or Plaster model scan
1) Implant Procedure2) Digital Abutment Placement3) Trios or Plaster model scan
1) CT and Trios Scan Data matching2) Provisional crown design3) Implant planning4) Guide stent design
1) Trios Scan data and Digital Abutment Library Matching2) Crown Design3) Prosthetic Production
1) Guide stent production2) Digital Abutment Library Matching3) Provisional crown Production (Abutment JIG)
T IP
In the case where the fixture implantation depth does not match the planning depth due to change of operation environment during surgery- It is possible to choose the different height cuffs of Digital Abutment.- The provisional Crown that is custom fitted to the DA can be used as it is even if the cuff changes and it can be modified on the field but if there is too much height difference, it should be remanufactured.- If not using the Provisional crown, healing can be induced by attaching a protect cap.
DIO Implant 66, Centum seo-ro, Haeundae-gu, Busan 612-020, Korea Tel +82 51 745 7777 Fax +82 51 745 7778 www.dioimplant.com