124 Technical data: Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 Hz Device consumption: approx. 4 VA Switching outputs: 16 (6) A/250 V~ Connecting cable button/switch: 230 V phase-independent supply cable Cable length up to 100 m 2-wire connection for COM: Cross-section as desired/length up to 100 m Admissible ambient temperature: –10 °C … +50 °C Protection class: Control unit: II according to EN 60730-1 when mounted in accordance with its designated use Protection type: Control units: IP 20 according to EN 60529 Channels: C1: Current pulse or time function 1…15 min with switch-off pre-warning (deselectable)/resettable and continuous function C2: Current pulse or time function 1…20 min with switch-off pre-warning (deselectable)/deactivatable and continuous function C3: Current pulse function C4: Current pulse function suitable for FI (RCD) in wet rooms Input cable length: up to 100 m, 230 V cables single- and multi-pole (NYM cable, NYIF riser, H05/H07 PVC wires) Use a screwdriver for programming U and I 4 inputs are potential-free • I 4 (L) I 4 (N) special connections for FI (RCD) in wet rooms • U1 is a universal voltage input for the activation via intercoms (8-48 V AC/DC) • Manual operation on the device for the installation test • Time range settings very easy to make directly on the device • Each module operates fully independently of the others (standalone function) For the online configurator, go to www.luxor400.com Living comfort controller (4 modules) Din rail program Luxury installation, simple and favorably priced! For the first time, it is possible to realize a luxury installa- tion in every housing facility. With LUXOR, we offer you the opportunity to satisfy the needs such as safety, comfort and energy savings of every home owner. Function: Modularly extendable system for standard living comfort installation. REG modules connected by means of a 2-wire COM interface. Expandable with up to 16 modules. Absolute functional safety by means of the “standalone” function of each module. The U and I 4 inputs are potential-free. Settings are very easy to make directly on the module. LUXOR 400 (base module) • Base module, expandable with up to 16 modules. • 4 x 16 A switching outputs • Manual switching • LEDs for displaying input/output signals • Potentiometers for adjusting the time functions • U1: Universal voltage input 8-48 V AC/DC • I 4 (L) and I 4 (N) for connecting FI (RCD) for wet rooms • 2-wire COM interface for communication with other modules • Adjustment possible for central ON/OFF, panic, and presence simulation • From generation*** capable of communication with LUXOR 411/412 and 414 LUXOR 400 (Basic module) 45,1 59,61 71,85 65,11 90 P LUXOR 400 S P LED lights up when a signal is active. LED lights up when the relay is switched on. Selector switch input button/switch Channel button for ON/OFF manual switching, and programming of the central functions Setting the resettable time function from 1 to 15 min with switch-off pre-warning (deselectable) and continuous light Setting the resettable time function from 1 to 20 min with switch-off pre-warning (deselectable) and continuous light Panic function Central OFF Presence simulation Central ON/Scene Operator interface: ! 1–20 min P S Dimension drawings Order No. LUXOR 400 (Basic module) 400 0 000

Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

124

Technical data:Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 HzDevice consumption: approx. 4 VASwitching outputs: 16 (6) A/250 V~Connecting cable button/switch:230 V phase-independent supply cableCable length up to 100 m2-wire connection for COM: Cross-section as desired/length up to 100 m

Admissible ambient temperature: –10 °C … +50 °CProtection class:Control unit: II according to EN 60730-1 when mounted in accordance with its designated useProtection type:Control units: IP 20 according to EN 60529

Channels:C1: Current pulse or time function

1…15 min with switch-off pre-warning (deselectable)/resettable and continuous function

C2: Current pulse or time function1…20 min with switch-off pre-warning (deselectable)/deactivatable and continuous function

C3: Current pulse functionC4: Current pulse function suitable for FI (RCD) in

wet rooms

Input cable length:up to 100 m, 230 V cables single- and multi-pole (NYM cable, NYIF riser,H05/H07 PVC wires)

Use a screwdriver for programming• U and I 4 inputs are potential-free• I 4 (L) I 4 (N) special connections for FI (RCD) in wet

rooms• U1 is a universal voltage input for the activation via

intercoms (8-48 V AC/DC)• Manual operation on the device for the installation test• Time range settings very easy to make

directly on the device• Each module operates fully independently of the others

(standalone function)

For the online configurator, go towww.luxor400.com

71,85

90

LUXOR 404

Living comfort controller (4 modules)

Din rail program

Luxury installation, simple and favorably priced!For the first time, it is possible to realize a luxury installa-tion in every housing facility. With LUXOR, we offer youthe opportunity to satisfy the needs such as safety,comfort and energy savings of every home owner.

Function:Modularly extendable system for standard living comfortinstallation. REG modules connected by means of a 2-wireCOM interface. Expandable with up to 16 modules. Absolutefunctional safety by means of the “standalone” function ofeach module. The U and I 4 inputs are potential-free. Settingsare very easy to make directly on the module.

LUXOR 400 (base module)• Base module, expandable with up to 16 modules.• 4 x 16 A switching outputs• Manual switching• LEDs for displaying input/output signals• Potentiometers for adjusting the time functions• U1: Universal voltage input 8-48 V AC/DC• I 4 (L) and I 4 (N) for connecting FI (RCD) for wet rooms• 2-wire COM interface for communication with other

modules• Adjustment possible for central ON/OFF, panic, and

presence simulation• From generation*** capable of communication with

LUXOR 411/412 and 414

LUXOR 400 (Basic module)

45,1

59,6171,85

65,11

90

P

LUXOR 400

S

P

LED lights up when a signal is active.

LED lights up when the relay is switched on.

Selector switch input button/switch

Channel button for ON/OFF manual switching, andprogramming of the central functions

Setting the resettable time function from 1 to 15 min withswitch-off pre-warning (deselectable) and continuous light

Setting the resettable time function from 1 to 20 min withswitch-off pre-warning (deselectable) and continuous light

Panic function

Central OFF

Presence simulation

Central ON/Scene

Operator interface:

!1–20 minPS

Dimension drawings Order No.

LUXOR 400 (Basic module) 400 0 000

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 124

Page 2: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

125

~, +10 %/–15 %

ox. 4 VAA/250 V~switch:pply cable

M: th up to 100 m

perature:

EN 60730-1 e with its designated use

g to EN 60529

functionoff pre-warning and continuous functionfunction

off pre-warning ble and continuous functionnn suitable for FI (RCD) in

ngle- and riser,

ogrammingal-freeections for FI (RCD) in wet

nput for the activation via

device for the installation testasy to make

y independently of the others

tor, go to

Living comfort controller (2/4 modules)

Din rail program

Function:Modular upgradeable LUXOR system for the standardliving comfort installation. REG modules connected via a2-wire COM interface. Upgradeable to max. 16 modules.Wholly reliable functionality thanks to the “stand-alone”function of each module. Completely floating and phase-independent inputs/outputs. Simplest settings on themodule itself.

LUXOR 404• 4 channel upgrade module• 4 x 16 A switching outputs• Manual controls• Display LED's• Potentiometers for setting the time function• I 4 (N) and I 4 (L) for connecting

FI (RCD) for wet rooms• U and I 4 inputs are potential-free• Switch-off pre-warning deselectable

LUXOR 402• 2 channel upgrade module• 2 x 16 A switching outputs with deactivatable time

function• Manual controsl• Display LED's• Key/switch selection option• U and I 4 inputs are potential-free• Switch-off pre-warning deselectable

LUXOR 404 (4-channel extension)

45,1

59,6171,85

65,11

90

LUXOR 404

LUXOR 402 (2-channel extension)

45,1

59,6144,85

65,11

90

LUXOR 402

!1–20 minPS

Leo Luxorwww.luxor400.com

FI (RCD)

P S

LUXOR 400

SP

Terminals for FI circuit breaker (RCD)

Application:For wet rooms such as. : Bathroom

Caution!Connect the FI circuit breaker (RCD) on the I 4 (L) and I 4 (N) terminals only (see figure).

The I 4 (N) terminal must be connected with or without FI(RCD) in every type of application!

Dimension drawings

!

400 0 000

Technical data:Operating voltage: 230 V, +10 %/–15 % Mains frequency: 50 HzPower consumption: approx. 4 VASwitch outputs: 16 (6) A/250 V~Contacts: floating working contactKey/switch connection: 230 V phase-independent supply cablecable length max. 100 m2-wire connection for COM: Any cross-section max. length 100 m

Permissible ambient temperature:–10 °C ... +50 °CProtection class: Control unit: II to EN 60730-1 for mounting with terminal box cover plateProtection rating: Control unit: IP 20 to EN 60529

Channels:C1: Current surge or time function

1…15 min with switch-off pre-warning (deselectable)/resettable and continuous function (immediately

resettable)C2: Current surge or time function

1…15 min with switch-off pre-warning (deselectable)/resettable and continuous function (immediatelyresettable)

C3: Current surge function (LUXOR 404 only)C4: Current surge function suitable for FI (RCD) for

wet rooms (LUXOR 404 only)

Order No.

LUXOR 404 (4-channel extension) 404 0 000LUXOR 402 (2-channel extension) 402 0 000

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 125

Page 3: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

126

Living comfort controller

Din rail program

Technical data for LUXOR 405:Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 HzPower consumption: approx. 3 VADimmer outputs: 2 x 300 VA or 1 x 500 VASuitable for filament bulbs, LV and HV halogen lampsConnecting cable key: 230 V phase-independentsupply cable, cable length max. 100 m2-wire connection for COM: Any cross-section/max. length 100 m

Permitted ambient temperature: –10 °C ... +50 °CProtection class to EN 60730-1: Control units: II formounting with terminal box cover plateProtection rating to EN 60529: Control units: IP 20

Channels:C1: Universal dimmer with 300 VA C2: Universal dimmer with 300 VA C1+ C2: Universal dimmer with 500 VA

Technical data for LUXOR 408/LUXOR 409:Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 HzPower consumption: approx. 4 VASwitch outputs: 6 VA/250 V~Connecting cable key: 230 V phase-independentsupply cable, cable length max. 100 m2-wire connection for COM: Any cross-section/max. length 100 m

Permitted ambient temperature: –10 °C ... +50 °CProtection class to EN 60730-1: Control units: II formounting with terminal box cover plateProtection rating to EN 60529: Control units: IP 20

Channels:C1 to C4: for shutter, blind and awning control

45,1

59,6171,85

65,11

90

LUXOR 405

Order No.

LUXOR 405 (Dimming module) 405 0 000LUXOR 408 (Shutter basic module) 408 0 000LUXOR 409 (Shutter upgrade module) 409 0 000DMB 2 (Power extension) 491 0 222

R, L, CPS M

LUXOR 405 (Dimming module)

DMB 2 (Power extension)

LUXOR 409 (Shutter upgrade module)

LUXOR 408 (Shutter basic module)

LUXOR 405 2-channel dimming moduleThe LUXOR 405 upgrade module is a universal dimmer forvarious lamp loads. It is suitable for both conventionaland electronic transformers. The device is also usablewithout basic module.

• 2-channel universal dimmer, each with 300 VA or 1-channel universal dimmer, with 500 VA

• Any number of keys can be connected to the inputsprovided

• Selection programs P1 to P4 as setting option for thedimming response

• Manual controls and display LED's• One additional input per channel for movement

indicator• Stand-alone function• Overcurrent display• CLEAR key for resetting in the event of malfunction• Setting input for 3 light settings

DMB 2 Power extension• Power extension (for LUXOR 405) of the 2 dimming

channels from 2 x 600 VA/1 x 1000 VA

LUXOR 408 Shutter basic moduleBasic shutter module for controlling a maximum of fourshutters, blinds or awnings. The module can be controlledby all familiar standard shutter keys. There are threegroups for individual channel programming and also thecentral UP/DOWN function. The module can be expandedwith channel upgrades and also with a time and sensormodule with connectable weather station.

• Selector switch for shutters, awnings and Venetian blindsfor each channel

• Separate control of 4 shutters with UP/DOWN/STOP• Central UP/DOWN of all shutters• Group function for one shutter group• Storable intermediate position for shading

and ventilation• UP/DOWN panic function controllable via LUXOR 400• Manual controls and display LED's• 6 A switching capacity per channel• Expandable by channel upgrade modules, time and

sensor module with optional connecting weatherstation

LUXOR 409 Shutter upgrade module• Separate control of 4 shutters with UP/DOWN/STOP• Central UP/DOWN of all shutters via LUXOR 408• Group functions for two shutter groups• Storable intermediate position for shading

and ventilation• UP/DOWN panic function controllable via LUXOR 400• Manual controls and display LEDs• 6 A switching capacity per channel

Dimension drawings

45,1

59,6171,85

65,11

90

LUXOR 408

71,85

90

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 126

Page 4: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

127

R 405:V~, +10 %/–15 %

rox. 3 VAVA or 1 x 500 VA

LV and HV halogen lamps30 V phase-independentax. 100 m

OM: th 100 m

erature: –10 °C ... +50 °C0730-1: Control units: II forcover plate

60529: Control units: IP 20

300 VA 300 VA with 500 VA

R 408/LUXOR 409:V~, +10 %/–15 %

rox. 4 VAV~

30 V phase-independentax. 100 m

OM: th 100 m

erature: –10 °C ... +50 °C0730-1: Control units: II forcover plate

60529: Control units: IP 20

and awning control

ule) 405 0 000module) 408 0 000de module) 409 0 000

491 0 222

M Living comfort controller

Din rail program/Wall mounting

Technical data:Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 HzDevice consumption: 5.5 VAInputs:3 light sensors1 wind sensor (LUXOR 413) or:connection for weather sensors (LUXOR 412) and 2 light sensorsWind speed: 2–20 m/sBrightness range:3 channels x 1000–100,000 lx (sun protection) 1 channel x 1–100 lx (twilight value)2-wire connection for COM:Cross-section as desired/length up to 100 m

Admissible ambient temperature:–10 °C … +50 °CProtection class according to EN 60730-1 whenmounted in accordance with its designated use: Control unit: IISensors: IIIProtection type according to EN 60529:Control units: IP 20Sensors: LUXOR 413 IP 43

Mounted light sensor IP 54

Accessories:

1–100.000 Lux

LUXOR 411 (sensor module)

LUXOR 411 (sensor module)+ max. 3 light sensors + wind sensorAutomatic control of shutters, Venetian blinds and awningsas a function of brightness, and automatic control of thegeneration 3 exterior lighting. If required, up to 3 light sensors with wall support can beconnected to the control device. • Three groups of blinds, e.g. on 3 different façades, can be

controlled separately and moved automatically to pre-defined positions (0–100 %). This requires one lightsensor for each façade.

• The automatic lighting control in the LUXOR system iseffected by the dimming switch channel with a settingrange of 1–100 lux. This allows, for example, entranceand house number lighting to be switched automatically(from generation 3***).

• The monitoring of the wind speed by means of theadditional wind sensor LUXOR 413 allows the sunprotection to drive automatically to a safe position, beforedamage can occur.

• The wind sensor (LUXOR 413) or the weather sensors canalso be retrofitted later on to the sensor module LUXOR411 (see page 102)

• For the wind sensor LUXOR 413, an additional powersupply unit is required

• Cable length of the sensor lines up to 100 m

45,1

59,6171,85

65,11

90

Order No.

LUXOR 411 (sensor module) 411 0 000Surface-mounted light sensor (max. 3) 907 0 008LUXOR 413 (sensor module) 413 0 000Power supply unitrequired for LUXOR 413 (4 modules) 907 9 330

Dimension drawings

Surface-mounted light sensor

LUXOR 413 (wind sensor optional)

Power supply unit 24 V DC(LUXOR 413)

115

mm85

mm

60 mm 28 mm

Connection diagram

LN

2 2 2

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 127

Page 5: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

128

Living comfort controller

Din rail program/Wall mounting

Technical data:Operating voltage:LUXOR 411: 230 V~, +10 %/–15 %LUXOR 412 is supplied by LUXOR 411 Mains frequency: 50 HzDevice consumption: 5.5 VAInputs:Connection for weather sensors including wind, rain,temperature and integrated light sensors (LUXOR 412)optional: 2 additional light sensors, 1 wind sensor (LUXOR 413)Brightness range:max. 3 channels: 1000–100,000 lx (sun protection)

1 channel: 1–100 lx (twilight value)Wind speed: 2–20 m/sTemperature range: 0 °C … +60 °C2-wire connection for COM:Cross-section as desired/length up to 100 m

Admissible ambient temperature:Control unit: –10 °C … +50 °CWeather sensors: –20 °C … +55 °CProtection class according to EN 60 730-1 when mounted in accordance with its designated use:Control unit: IISensors: IIProtection type according to EN 60 529:Control units: IP 20Sensors: IP 44

LUXOR 411 (sensor module)

LUXOR 411 + LUXOR 412 weather sensorsThe complete system for the reliable control of awnings,shutters and Venetian blinds – regardless of stormy, rainyor snowy weather. The weather sensory system providereliable protection, have everything under control and tellthe individual channels of the shutter modules in theLUXOR system what they have to do. For example, whichslat position the blinds are to move to, depending on thesun’s position. Starting from a set lux value, the pre-selectedblinds/awnings will move automatically to the pre-definedposition (0–100 %). Optionally, 2 additional light sensorscan be used to control a total of 3 groups of blindsdifferently, e. g. for 3 façades. • The monitoring of the wind speed allows the sun

protection to drive automatically to a safe position,before damage can occur.

• Shutters, exterior, entrance and house number lightingcan be controlled automatically by the LUXOR system bymeans of the twilight value setting. (from generation3***)

• Simple wall mounting by sensor arm that can be tiltedupward

• Optional mounting to pole up to Ø 60 mm• Cable length of the sensor lines up to 100 m• Frost is fixed to +3 °C, for awnings only

45,1

59,6171,85

65,11

90

Order No.

LUXOR 411 (sensor module) 411 0 000LUXOR 412 (weather sensory system) 412 0 000Surface-mounted light sensor 907 0 008Mast mounting (for LUXOR 412) 907 0 380

Dimension drawings

LUXOR 412 (weather sensory system)

Connection diagram

LN

2

2

2

135

66

280

160

1–100.000 Lux m/s ϑ

EAST WEST

2 SOUTH

44,85

90

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 128

Page 6: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

129

Living comfort controller

Din rail program

Technical data:Operating voltage: 230 V~, +10 %/–15 % Mains frequency: 50 HzDevice consumption: approx. 4 VA2-wire connection for COM:Cross-section as desired/length up to 100 mMemory locations: 128Power reserve: 5 h

Admissible ambient temperature: –10 °C … +50 °CProtection class according to EN 60 730: II whenmounted in accordance with its designated useProtection type according to EN 60 529: IP 20LUXOR 414 (clock modul)

LUXOR 414 (clock module)8-channel system clock for controlling any outputs of theLUXOR system. The time switch provides daily and weeklyprograms and also includes the option of astronomicalprograms for switching in accordance with sunrise andsunset. These features allow blinds and shutters to becontrolled and positioned comfortably and fully automati-cally in the range from 0 to 100 %.Automatic lighting control at the entrance area or allaround the house provides increased safety at nightfall.The automatic nighttime switch-off provides saving ofenergy.• 8 channels optionally with daily, weekly or astronomic

program• 128 freely programmable switching times and 732

preprogrammed astronomic switching times• Local database for simple entering of the location• Individual linking of the time switch channels to the

outputs by means of a selector switch• Positioning of drives (LUXOR 408/LUXOR 409) and

transmission of the dimming values (LUXOR 405) inpercent values 0–100 %

• Option to set manual or automatic mode• Off periods to suppress brightness or twilight signals

from the sensor module LUXOR 411 e. g. to suppresslighting in the early morning in summer

• Astronomic off periods to change the times of the upand down movements of shutters/awnings

• Offset ±120 min• Automatic summertime/wintertime change• User guidance by means of text line in the display

/–15 %XOR 411

VA

ors including wind, rain,ight sensors (LUXOR 412)ensors, 1 wind sensor

,000 lx (sun protection) value)

… +60 °CM:th up to 100 m

perature:°C+55 °Cg to EN 60 730-1 when

with its designated use:

g to EN 60 529:

e) 411 0 000ory system) 412 0 000ensor 907 0 008R 412) 907 0 380

Connection diagram

LN

±1hauto

Astro ±120 min%24 h7 d

Order No.

LUXOR 414 (clock modul) 414 0 000

Dimension drawings

45,1

59,61

65,11

44,85

90

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 129

Page 7: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

LUXOR 411Sensor module

�� ��

I1I1 I3I3I2I2

���� ��������

�� �

��

�� ��� �� �

I1I1 I2I2

I4 (N)I4 (N) I4 (L)I4 (L)

I3I3

��

������������

SOUTH

EAST WEST

T1 T2 T4T3 T

tLUXOR 400

T

LUXOR 402Upgrade module

LUXOR 400Basic module

Type

LUXOR 405Dimming module

LUXOR 404Upgrade module

LUXOR 408Roller shutter basic module

LUXOR 409Roller shutter upgrade module

Diode module for special fun

DMB 2Upgrade device

Surface-mounted light sen

LUXOR 412Weather sensor

Mast installation for LUXOR

LUXOR 413Wind sensor

Power supply unit needed fo

LUXOR 414Time module

LUXOR Set 3LUXOR Set 4

LUXOR Set 2

Living comfort controller

Startersets

130

Set 2:Convenience set for a single-family house. 8 separate lighting points with 3 central functions and 4time functions (for hallway, basement, outside lightingetc.).

Set 4:The perfect set for controlling roller shutters and Venetianblinds. 8 drives can be controlled individually or in groups,as well as manually or automatically, based on a scheduleor sunrise/sunset program. Blocked times allow you toprevent roller shutters and sun blinds from going up anddown in early morning hours. Also with convenient centralfunctions.

All 4 sets can be expanded as needed.

LUXOR Set 2:Suitable for 8 separate lighting units, 4 x time/switch and 4 x switch• Box• 1 LUXOR 400• 1 LUXOR 404

LUXOR Set 4:Suitable for 8 drives for roller shutters and Venetianblinds, 8 drives and 8 time channels with week programand astronomical clock• Box• 1 LUXOR 408• 1 LUXOR 409• 1 LUXOR 414

LUXOR Set 2

LUXOR Set 4

Set 3:The ideal set for a large single-family house with 10 separate lighting points and 4 time functions. Extradimming channels for living rooms, bedrooms etc. This setalso provides the advantages offered by the central functions.

LUXOR Set 3:Suitable for 10 separate lighting units, 4 x time/switch and 4 x switch, 2 x dimming• Box• 1 LUXOR 400• 1 LUXOR 404• 1 LUXOR 405

LUXOR Set 3

122_175_GB_2008 07.07.2008 15:37 Uhr Seite 130

Page 8: Din rail program - Duarte Neves · LUXOR 409 Shutter upgrade module • Separate control of 4 shutters with UP/DOWN/STOP • Central UP/DOWN of all shutters via LUXOR 408 • Group

LUXOR 411 – Threshold value brightness, wind, – – – 411 0 000Sensor module twilight and temperature

Switch

131

Living comfort controller

Installation

Connection of inputs/outputs and comfort functions (example)

*

Lighting Dimming Roller shutter with Sun protection Venetian and sun blinds

�� ��

I1I1 I3I3I2I2 I4I4

���� �������� ����

�� ���

��

�� ��� �� �

I1I1 I2I2

I4 (N)I4 (N) I4 (L)I4 (L)

I3I3

��

����������������

� �

L

N16 A

S

SOUTH

EAST WEST

T1 T2 T4T3 T T LS D1 BW2

ttttLUXOR 400 LUXOR 405 LUXOR 408

tLUXOR 411

T BW1

G1

=D2

LUXOR 414

Time control

*

LUXOR 402 2 Switch Presence simulation, 2 NO contact 16 A 402 0 000Upgrade module Time Central OFF, Panic function

LUXOR 400 4 Switch Presence simulation, 4 NO contact 16 A 400 0 000Basic module Time Central OFF, Panic function

Type Channels Function Central functions in conjunction Outputs Nominal current Order No.with basic modules floating at 250 V~

LUXOR 405 2 Dimming, Lightsetting, Presence simulation, 2 Triacs 2 x 300 W/VA 405 0 000Dimming module Nightlight Central OFF, Panic function (1 x 500 W/VA)

LUXOR 404 4 Switch Presence simulation, 4 NO contact 16 A 404 0 000Upgrade module Time Central OFF, Panic function

LUXOR 408 4 Motor control Central UP/DOWN, Panic 8 NO contact 6 A 408 0 000Roller shutter basic module 1 group

LUXOR 409 4 Motor control Central UP/DOWN, Panic 8 NO contact 6 A 409 0 000Roller shutter upgrade module 2 groups

Diode module for special functions (group function/central function) necessary Set with 2 devices 907 0 367

DMB 2 2 Dimming booster – 2 Triacs 2 x 600 W/VA 491 0 222Upgrade device (1 x 1000 W/VA)

Surface-mounted light sensor for LUXOR 411 907 0 008

LUXOR 412 – Sensor for brightness, twilight, – – – 412 0 000Weather sensor temperature, wind, rain

Mast installation for LUXOR 412/LUXOR 413, up to Ø 60 mm 907 0 380

LUXOR 413 – Wind sensor – – – 413 0 000Wind sensor

Power supply unit needed for LUXOR 413 907 9 330

LUXOR 414 8 Daily, weekly and – – – 414 0 000Time module astronomical program

*