52
® DIRECT CURRENT MOTORS Technical Catalogue November 2017 web edition

DIRECT CURRENT MOTORS - Dana SAC Benelux...2019/02/09  · A1- D1E1+ M A2E2- D1E1+ M A2E2-0 2 4 6 8 10 12 14 16 18 20 22 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 24 US l/min

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • ®

    DIRECT CURRENT MOTORS

    Technical Catalogue

    November

    2017

    web edition

  • 1IE/INDEX/02-2013

    Index

    DC motors

    Description Type Page

    Introducion 2

    12V DC - 0.35 kW - D.80 25021400 4

    24V DC - 0.4 kW - D.80 25021500 6

    12V DC - 0.5 kW - D.80 25024200 8

    24V DC - 0.5 kW - D.80 25024300 10

    12V DC - 0.7 kW - D.80 25021600 12

    24V DC - 0.8 kW - D.80 25021700 14

    12V DC - 0.8 kW - D.80 25021800 16

    24V DC - 0.8 kW - D.80 25021900 18

    12V DC - 1.6 kW - D.115 25021100 20

    24V DC - 2.2 kW - D.115 25021200 22

    12V DC - 1.5 kW - D.115 25022200 24

    12V DC - 1.5 kW - D.115 25022200 FAN 26

    24V DC - 2.0 kW - D.115 25022300 28

    24V DC - 2.0 kW - D.115 25022300 FAN 30

    12V DC - 1.6 kW - D.115 25022000 32

    24V DC - 2.2 kW - D.115 25022100 34

    12V DC - 1,6 kW - D.115 25022600 36

    24V DC - 2,2 kW - D.115 25022700 38

    24V DC - 3.0 kW - D.125 25021300 40

    24V DC - 3.0 kW - D.125 25021300 FAN 42

    24V DC - 3.0 kW - D.125 25022400 44

    24V DC - 3.0 kW - D.125 25022400 FAN 46

    Starting switch 120A 48

    Starting switch 150A 48

    © 2017 Dana Brevini Fluid Power S.p.A. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology, logos are trademarks or are registered trademarks of Dana Brevini Fluid Power S.p.A. or other companies Dana in Italy and other countries.

    The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana Brevini Fluid Power will not be held responsible for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical features of our products, Dana Brevini Fluid Power reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced (in while or in part) without the prior written consent of Dana Brevini Fluid Power. This catalogue supersedes all previous ones.

    Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating condi-tions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items.

    ®

  • 2IE/INTRO/02-2017

    A2+

    M

    A1- D1E1+

    M

    A2E2- D1E1+

    M

    A2E2-

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    4843

    38

    32

    2622

    2017

    1512

    63

    10 l/min

    IntroductionThis collection of technical tables lists all the DC motors approved by Dana Brevini Fluid Power and used in power units of its standard production. Dana Brevini Fluid Power offers a wide range of DC motors with rated voltage from 12 V to 24 V and power from 350 W to 3000 W. The diagrams shown are de-termined from tests performed with the characteristics specified in the same technical tables” and using the standard power units manufactured by Dana Brevini Fluid Power.The curves thus show the performances of the power unit in relation to the pump installed. One table describes the main characteristics of the pumps specifying their size (group)

    Motor typologyThe two main types of DC motors used by Dana Brevini Fluid Power are: • With permanent magnets, generally low power motors, reversible, in

    which the magnetic field is generated by permanet magnets and excita-tion is constant;

    • With wound fields: generally medium power, unidirectional, where both excitation and armature windings are electrically driven. These are then divided into two other families: series coonection and compound.

    Duty cycleIn order to ensure the correct choice of the motor, must be known the type of duty cycle required by the application and it has to be compared with the motor features.Duty types S1, S2, S3 are defined according to standards EN 60034-1, cor-responding to CEI 2-3.

    DefinitionsDuty typeA continuous, short time or periodic duty, comprising one or more loads re-maining constant for the duration specified, or a non-periodic duty in which generally load and speed vary within the permissible operating range.

    Thermal equilibriumThe state reached when the temperature rises of the several parts of the machine do not vary by more than 2°C over a period of 1 h.

    Cyclic duration factorThe ratio between the period of loading, including starting and electric brak-ing, and the duration of the duty cycle, expressed as a percentage.

    Continuous running duty – Duty type S1Operation at constant load of sufficient duration for thermal equilibrium to be reached.

    Short time duty – Duty type S2Operation at constant load during a given time, less than that required to reach thermal equilibrium, followed by a rest and de-energized period of suf-ficient duration to re-establish initial conditions

    Intermittent periodic duty – Duty type S3A sequence of identical duty cycles, each including a period of operation at constant load and a rest and de-energized period. The duration of a cycle is generally 10 min. The value S3 is expressed as a percentage For example S3= 25% means that the load on the motor can be constant for 25% of cycle time (2.5 minutes); then you need a rest position for the remaining 75 % of cycle time (7.5 minutes) before starting over a new cycle.

    Protection degreeThe degree of protection is indicated in accordance with standard EN 60034-5 corresponding to CEI 2-16. The codes to indicate degree of protection are made by the letters IP followed by two characteristics numerals.

    The protection degree are valid in many cases only for motors assembled on power units or other products manufactured by Dana Brevini Fluid Power.

    Insulation classThe insulation class indicated is in accordance with standard EN correspond-ing to CEI 15-26. It indicates the maximum appropriate temperature for the product in nominal operating conditions, without damages to the insulating material of the motor.

    Insulation class Y A E B F H

    Temperature (°C) 90 105 120 130 155 180

    How to choice the motorEach motor has its own characteristic curve. The main specifications are: flow rate (in l/min or US gpm), pressure (in bar or psi), current (in Ampere) and duty type S2 (in minutes) or S3 (in percentage of working time).

    Reference data • Maximum nominal pressure Pmax = 290 Bar (4206 psi)• Oil ISO VG32 at temperature 35°C (viscosity 40 cSt)• Outside temperature 25°C• Maximum nominal current Imax = 300A • Constant stabilized voltage detected at the terminals of the electric motor.

    As a function of pressure and pump displacement, determines the flow rate, drawing a vertical line from the pressure value, intercepting the curve relat-ing the pump, in fact you can read the flow rate on the ordinate. For example: pressure 100 bar (1450 psi), pump 3.8 cm³/rev (0.23 in³/rev), you have a flow rate of 10 l/min (2.6 US gpm).

    Permanent magnets

    Wound fieldsSeries Compound

    Reversible (nominal left)

    Unidirectional left

    Unidirectional left

    ®

  • 3IE/INTRO/02-2017

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26 22 20

    17

    15

    12

    63

    217 A

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280

    1.55 min

    5.1 %

    Introduction

    Start switchSwitch ON/OFF

    Thermal switch(optional)

    Battery

    Similarly you can read the value of current absorption in the related diagram. With the same data of the previous example you have a current consumption of 217 A.

    Taking again the current consumption on the S2-S3 diagram, you have a S2 duty equal to 1.55 ( 1’32’’) minutes and a S3 duty equal to 5.1 % (30 s on a cycle of 10 minutes).

    Example of installationThe following i san example of electrical connection

    All electrical connections and disconnections must be performed by trained, specialized personnel.

    When wiring a motor, it is important to consider the cross-sectional area and length of the power cables. Cables with overly small cross-sections and overly long lengths may cause voltage drops that could prevent the PU from operating properly.

    ISO M8 5 ÷ 7 Nm [3.69 ÷ 5.16 lbf · ft]

    ISO M6 3 ÷ 5 Nm [2.21 ÷ 3.69 lbf · ft]

    5/16-18 UNC-2A 5 ÷ 7 Nm [3.69 ÷ 5.16 lbf · ft]

    Quantity Unit Symbol Other units Symbol Equivalence Reverse Equivalence

    Flow rate Liters at minutes l/minUS Gallon /minutes US gal/min 1 US gal/min=3.7848 l/min 1 l/min = 0. 2642 US gal/minUK Gallon /minutes Imp gal/min 1 Imp gal/min=4.5456 l/min 1 l/min = 0.2199 Imp gal/minCubic feet /minutes cu ft/min 1 cu ft/min= 28.32 l/min 1 l/min = 0.0353 cu ft/min

    Pressure bar bar

    Pascal Pa 1 Pa= 10-5 bar 1 bar= 105 PaAtmosphere Atm 1 atm = 1.0132 bar 1 bar= 0.9869 atmKilogram force on cm² kgf /cm² 1 kgf /cm² = 0.9806 bar 1 bar= 1.0197 kgf/cm²Pound force on in² lbf/in² or psi 1 psi = 0.068948 bar 1 bar= 14.5038 psi

    Unit of measure conversion

    V = displacement (cm³/rev)Q = flow rate (l/min)T = torque (Nm)N = power (kW)n = speed (rpm)

    P = pressure difference between inlet and outlet (bar)

    mecc = mechanical efficiency

    vol = volumetric efficiency

    tot = total efficiency

    Flow rate from pump

    Torque absorbed by pump

    Power absorbed by pump

    Total efficiency

    Main formulae

    Use these tightening torque values on the motor terminals and the start switch.

    Q[l/min] = V[cm³/rev] · n[rpm] · vol

    · 10 -3

    T[Nm] = V[cm³/rev] · P [bar]

    20 · mecc

    N[kW] = 2 · 10 -3 · T[Nm] · n[rpm]

    60=

    Q[l/min] · P [bar]

    600 · tot

    tot =

    mecc ·

    vol

    Connection withoutthermal switch

    ®

  • 4

    25021400

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021400/01-2012

    88 [3.46]13.5 [0.53] 15.5 [0.73]

    143.5 [5.65]

    Ø76 [2.9

    9]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø80 [3.1

    5]

    50 [1.9

    7] M6

    101 [3.9

    8]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    Ø7 [0.28]

    mm [inches]

    12 VDC - 0.35 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 12 VDCPower 0.35 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.2 kg [4.85 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 5

    25021400

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    60

    65

    70

    75

    80

    85

    90

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    04070912 05

    02

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    21

    24

    27

    30

    33

    36

    39

    42

    45

    48

    51

    54

    S2 (min) S3 (%)

    Amp25 30 35 40 45 50 55 60 65 70 75 80 85

    IE/25021400/01-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 80A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021400 12VDC motor - 0.35 kW

    Code Description

    KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

    ®

  • 6

    25021500

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021500/00-2012

    88 [3.46]13.5 [0.53] 15.5 [0.73]

    143.5 [5.65]

    Ø76 [2.9

    9]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø80 [3.1

    5]

    50 [1.9

    7] M6

    101 [3.9

    8]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    Ø7 [0.28]

    mm [inches]

    24 VDC - 0.4 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 24 VDCPower 0.4 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.2 kg [4.85 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 7

    25021500

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    070912 05

    S2

    S3

    0 0

    2 6

    4 12

    6 18

    8

    10

    12

    14

    16

    18

    20

    24

    30

    36

    42

    48

    54

    60

    S2 (min) S3 (%)

    Amp5 10 15 20 25 30 35 40 45 50 55

    IE/25021500/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 50A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021500 24VDC motor - 0.4 kW

    Code Description

    KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

    ®

  • 8

    25024200

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25024200/01-2013

    mm [inches]

    19 [0.75]

    Ø 7

    8 [3

    .07]

    32,4

    [1.2

    8]

    M6

    154,9 [6.1]13.5 [0.53]

    101 [3.98]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø7.2

    [0.28]

    88 [3.4

    6]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    12 VDC - 0.5 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 12 VDCPower 0.5 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.5 kg [5.51 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 9

    25024200

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    60

    65

    70

    75

    80

    85

    90

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    04070912 05

    02

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    21

    24

    27

    30

    33

    36

    39

    42

    45

    48

    51

    54

    S2 (min) S3 (%)

    Amp25 30 35 40 45 50 55 60 65 70 75 80 85

    IE/25024200/01-2013

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 80A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25024200 12VDC motor - 0.35 kW

    Code Description

    KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

    ®

  • 10

    25024300

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25024300/01-2013

    mm [inches]

    19 [0.75]

    Ø 7

    8 [3

    .07]

    32,4

    [1.2

    8]

    M6

    154,9 [6.1]13.5 [0.53]

    101 [3.98]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø7.2

    [0.28]

    88 [3.4

    6]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    24 VDC - 0.5 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 24 VDCPower 0.5 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.5 kg [5.51 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 11

    25024300

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    070912 05

    S2

    S3

    0 0

    2 6

    4 12

    6 18

    8

    10

    12

    14

    16

    18

    20

    24

    30

    36

    42

    48

    54

    60

    S2 (min) S3 (%)

    Amp5 10 15 20 25 30 35 40 45 50 55

    IE/25024300/01-2013

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 50A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25024300 24VDC motor - 0.5 kW

    Code Description

    KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

    ®

  • 12

    25021600

    162 [6.38]

    115 [4.53]13.5 [0.53]

    Ø76 [2.9

    9]

    101 [3.9

    8]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]Ø7 [0.28]

    88 [3.46]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    M6

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    5.5

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021600/00-2012

    mm [inches]

    12 VDC - 0.7 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 12 VDCPower 0.7 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.7 kg [5.95 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 13

    25021600

    0

    20

    10

    40

    30

    60

    50

    80

    90

    70

    100

    110

    120

    130

    140

    150

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05070912

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    14

    15

    21

    24

    27

    30

    33

    36

    39

    42

    45

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

    IE/25021600/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021600 12VDC motor - 0.7 kW

    Code Description

    KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

    ®

  • 14

    25021700

    162 [6.38]

    115 [4.53]13.5 [0.53]

    Ø76 [2.9

    9]

    101 [3.9

    8]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]Ø7 [0.28]

    88 [3.46]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    M6

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    5.5

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021700/00-2012

    mm [inches]

    24 VDC - 0.8 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 24 VDCPower 0.8 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.7 kg [5.95 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 15

    25021700

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    60

    65

    70

    75

    80

    85

    90

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    12 09 07

    04

    02

    05

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    21

    24

    27

    30

    33

    36

    39

    S2 (min) S3 (%)

    Amp5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

    IE/25021700/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 80A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021700 24VDC motor - 0.8 kW

    Code Description

    KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

    ®

  • 16

    25021800

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    5.5

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021800/02-2013

    mm [inches]

    19 [0.75]

    Ø 7

    8 [3

    .07]

    32,4

    [1.2

    8]

    M6

    154,9 [6.1]13.5 [0.53]

    101 [3.98]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø7.2

    [0.28]

    88 [3.4

    6]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    12 VDC - 0.8 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 12 VDCPower 0.8 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.5 kg [5.51 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 17

    25021800

    0

    20

    10

    40

    30

    60

    50

    80

    90

    70

    100

    110

    120

    130

    140

    150

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05070912

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    14

    15

    21

    24

    27

    30

    33

    36

    39

    42

    45

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

    IE/25021800/02-2013

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021800 12VDC motor - 0.8 kW

    Code Description

    KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

    ®

  • 18

    25021900

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    5.5

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    02

    07

    09

    12

    04

    05

    IE/25021900/02-2013

    mm [inches]

    19 [0.75]

    Ø 7

    8 [3

    .07]

    32,4

    [1.2

    8]

    M6

    154,9 [6.1]13.5 [0.53]

    101 [3.98]

    6.5 [0.26]

    6.5 [0.26]

    3 [0.12]

    Ø7.2

    [0.28]

    88 [3.4

    6]

    Ø80 [3.1

    5]

    Ø14.9

    [0.5

    9]

    6.4

    [0.2

    5]

    24 VDC - 0.8 KW - D.80 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Voltage 24 VDCPower 0.8 kWNominal diameter 80 mm [3.15 in]

    Motor type PermanentmagnetRotation CCW-CWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 2.5 kg [5.51 lb]

    Code cc/rev. GR (Size)02 0.25 0504 0.45 0505 0.56 0507 0.75 05/109 0.9 05/112 1.2 05/1

    ®

  • 19

    25021900

    0

    10

    5

    20

    15

    30

    25

    40

    45

    35

    50

    55

    60

    65

    70

    75

    80

    85

    90

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    12 09 07

    04

    02

    05

    S2

    S3

    0 0

    1 3

    2 6

    3 9

    4 12

    5 15

    6 18

    7

    8

    9

    10

    11

    12

    13

    21

    24

    27

    30

    33

    36

    39

    S2 (min) S3 (%)

    Amp5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

    IE/25021900/02-2013

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 80A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021900 24VDC motor - 0.8 kW

    Code Description

    KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

    ®

  • 20

    25021100

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    4843

    38

    32

    2622

    2017

    1512

    63

    133 [5.24]

    158 [6.22]

    Ø98.3 [3.87]

    Ø114 [4.4

    9]

    90.4

    [3.5

    6]

    Ø35 [1.3

    8]

    Ø15 [0.5

    9]

    6.4

    [0.2

    5]

    1/4-20UNC

    12.3 [0.48] max

    11 [0.43] max

    M5 n°2

    M8

    9.1 [0.36] max

    D1E

    1A

    2E

    2

    IE/25021100/00-2012

    mm [inches]

    12 VDC - 1.6 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 12 VDCPower 1.6 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 21

    25021100

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26 22 20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280

    IE/25021100/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021100 12VDC motor - 1.6 kW

    25016600 12VDC motor - 1.6 kW with thermal switch

    90340008 Thermal switch

    Code Description

    KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)

    Motor with thermal switch

    ®

  • 22

    25021200

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    48

    43

    38

    32 26

    63

    2220171512

    133 [5.24]

    158 [6.22]

    Ø98.3 [3.87]

    Ø114 [4.4

    9]

    90.4

    [3.5

    6]

    Ø35 [1.3

    8]

    Ø15 [0.5

    9]

    6.4

    [0.2

    5]

    1/4-20UNC

    12.3 [0.48] max

    11 [0.43] max

    M5 n°2

    M8

    9.1 [0.36] max

    D1E

    1A

    2E

    2

    IE/25021200/00-2012

    mm [inches]

    24 VDC - 2.2 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 24 VDCPower 2.2 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 23

    25021200

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26

    22

    20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

    IE/25021200/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021200 24VDC motor - 2.2 kW

    25016700 24VDC motor - 2.2 kW with thermal switch

    90340008 Thermal switch

    Code Description

    KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)

    Motor with thermal switch

    ®

  • 24

    25022200

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    4843

    38

    32

    2622

    2017

    1512

    63

    111 [4.37]

    173 [6.81]

    Ø98.35 [3.87]

    Ø112 [4.4

    1]

    90.5

    [3.5

    6]

    Ø35 [1.3

    8]

    Ø15 [0.5

    9]

    6.4

    [0.2

    5]

    1/4-20UNC

    12 [0.47]

    6.4 [0.25]

    Ø 5.5 N° 6

    [0.22]

    M8

    8.5 [0.33]

    IE/25022200/00-2012

    mm [inches]

    12 VDC- 1.5 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0,9 05/1 43 4.3 110 1,0 05/1 48 4.8 112 1,2 05/1 60 6.0 115 1,5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 12 VDCPower 1.5 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 25

    25022200

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26 22 20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280

    IE/25022200/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022200 12VDC motor - 1.5 kW

    Code Description

    KIT07012.033 Starting switch kit 12VDC - 120A (fixing with clamp)

    ®

  • 26

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    4843

    38

    32

    2622

    2017

    1512

    63

    IE/25022200 FAN/02-2014

    157 [6.18]

    5 [0.2

    ]

    Ø14,8

    [0.5

    8]

    Ø35 [1.3

    8]

    Ø112 [4.4

    1]

    173 [6.81]46 [1.81]

    Ø 1

    16,6

    [4.5

    9]

    118 [4.6

    5]

    132 [5.2

    ]

    219 [8.62]

    Ø 110 [4.33]

    118 [4.65]

    132 [5.2]

    M8

    Ø 5.5 [0.22] N.6

    M8

    X

    mm [inches]

    12 VDC - 1.5 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0,9 05/1 43 4.3 110 1,0 05/1 48 4.8 112 1,2 05/1 60 6.0 115 1,5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 12 VDCPower 1.5 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 10

    S2 / S3 duty service see curvesInsulation class FWeight 7.4 kg [16.31 lb]

    X = see ordering code

    25022200 FAN®

  • 27

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26 22 20

    17

    15

    12

    63

    IE/25022200 FAN/02-2014

    S2

    S3

    0 0

    4 4

    8 8

    12 12

    16 16

    20 20

    24 24

    28 28

    32 32

    36 36

    40

    44 40

    44

    S2 (min) S3 (%)

    Amp110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    KIT07012.033 Starting switch kit 12VDC - 120A (fixing with clamp)Powerpack

    X mm [inch]

    Code Fan cooled

    motor

    Code Fan cooled

    motorwith thermal

    swich

    Code Fan cooled

    kit

    FP 52.6 [2.07] KIT09008.061 KIT09008.062 25017800

    MC 41.6 [1.64] KIT01008.065 KIT01008.088 25002300

    25022200 FAN

    Motor with thermal switch

    ®

  • 28

    25022300

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    48

    43

    38

    32 26

    63

    2220171512

    111 [4.37]

    173 [6.81]

    Ø98.35 [3.87]

    Ø11

    2 [

    4.4

    1]

    90

    .5 [

    3.5

    6]

    Ø3

    5 [

    1.3

    8]

    Ø1

    5 [

    0.5

    9]

    6.4

    [0

    .25

    ]

    1/4-20UNC

    12 [0.47]

    6.4 [0.25]

    Ø 5.5 N° 6

    [0.22]

    M8

    8.5 [0.33]

    IE/25022300/00-2012

    mm [inches]

    24 VDC - 2.0 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 24 VDCPower 2.0 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 29

    25022300

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26

    22

    20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

    IE/25022300/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022300 24VDC motor - 2.0 kW

    Code Description

    KIT07012.034 Starting switch kit 24VDC - 120A (fixing with clamp)

    ®

  • 30

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    48

    43

    38

    32 26

    63

    2220171512

    IE/25022300 FAN/02-2014

    157 [6.18]

    5 [0.2

    ]

    Ø14,8

    [0.5

    8]

    Ø35 [1.3

    8]

    Ø112 [4.4

    1]

    173 [6.81]46 [1.81]

    Ø 1

    16,6

    [4.5

    9]

    118 [4.6

    5]

    132 [5.2

    ]

    219 [8.62]

    Ø 110 [4.33]

    118 [4.65]

    132 [5.2]

    M8

    Ø 5.5 [0.22] N.6

    M8

    X

    mm [inches]

    24 VDC - 2.0 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 24 VDCPower 2.0 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 10

    S2 / S3 duty service see curvesInsulation class FWeight 7.4 kg [16.31 lb]

    25022300 FAN

    X = see ordering code

    ®

  • 31

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26

    22

    20

    17

    15

    12

    63

    IE/25022300 FAN/02-2014

    S2

    S3

    0 0

    4 4

    8 8

    12 12

    16 16

    20 20

    24 24

    28 28

    32 32

    36 36

    44

    40

    44

    40

    S2 (min) S3 (%)

    Amp40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    KIT07012.034 Starting switch kit 24VDC - 120A (fixing with clamp)Powerpack

    X mm [inch]

    Code Fan cooled

    motor

    Code Fan cooled

    motorwith thermal

    swich

    Code Fan cooled

    kit

    FP 52.6 [2.07] KIT09008.031 KIT09008.063 25017800

    MC 41.6 [1.64] KIT01008.067 KIT01008.077 25002300

    25022300 FAN

    Motor with thermal switch

    ®

  • 32

    25022000

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    4843

    38

    32

    2622

    2017

    1512

    63

    IE/25022000/00-2012

    M5 n°2

    Ø35 [1.3

    8]

    Ø112 [4.4

    1] Ø15 [0.5

    9]

    6.4

    3 [0.2

    5]

    11 [0.43]

    11.8 [0.46] 173 [6.81]

    115 [4.53]8.4 [0.33]

    Ø98.35 [3.87]

    90 [3.5

    4]

    1/4-20UNC

    M8

    mm [inches]

    12 VDC - 1.6 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 12 VDCPower 1.6 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 33

    25022000

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26 22 20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280

    IE/25022000/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Code Description

    KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022000 24VDC motor - 1.6 kW

    ®

  • 34

    25022100

    00

    0.5

    0.50

    0.75

    0.25

    1.00

    1.25

    1.0

    5.0

    4.5

    4.0

    3.5

    3.0

    2.5

    2.0

    1.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    05

    07

    09

    10

    04

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    24

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78

    60

    48

    43

    38

    32 26

    63

    2220171512

    IE/25022100/00-2012

    M5 n°2

    Ø35 [1.3

    8]

    Ø112 [4.4

    1] Ø15 [0.5

    9]

    6.4

    3 [0.2

    5]

    11 [0.43]

    11.8 [0.46] 173 [6.81]

    115 [4.53]8.4 [0.33]

    Ø98.35 [3.87]

    90 [3.5

    4]

    1/4-20UNC

    M8

    mm [inches]

    24 VDC - 2.2 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 1

    Voltage 24 VDCPower 2.2 kWNominal diameter 115 mm [4.53 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    ®

  • 35

    25022100

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    07

    09

    10

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32 26

    22

    20

    17

    15

    12

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

    IE/25022100/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Code Description

    KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022100 24VDC motor - 2.2 kW

    ®

  • 36

    25022600

    00

    0.50

    0.75

    0.25

    1.00

    1.25

    1.50

    1.75

    2.00

    1.0

    5.0

    6.0

    7.0

    8.0

    4.0

    3.0

    2.0

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    09

    10

    07

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    22 2017

    1512

    48

    60

    43

    3832

    26

    IE/25022600/00-2012

    Ø114.3

    [4.5

    ]

    Ø35 [1.3

    8] Ø

    15 [0.5

    9]

    6.4

    3 [0.2

    5]

    9.1 [0.36]

    11.8 [0.46]

    M5 n°2

    121.2 [4.77]8.4 [0.33]

    Ø98.32 [3.87]161.8 [6.37]

    90.4

    [3.5

    6]

    1/4-20UNC

    5-1

    6-1

    8U

    NC

    -2A

    mm [inches]

    12 VDC - 1.6 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

    Voltage 12 VDCPower 1.6 kWNominal diameter 115 mm [4.53 in]

    Motor type Serie “U”(USA)Rotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 117 1.7 120 2.0 1

    ®

  • 37

    25022600

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    04

    05

    10

    09

    07

    02

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    60 48 43 38 32 26 22

    20

    12

    17

    15

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280

    IE/25022600/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022600 12VDC motor - 1.6 kW

    25022800 12VDC motor - 1.6 kW with thermal swich

    Motor with thermal switch

    Code Description

    KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)

    ®

  • 38

    25022700

    00

    0.50

    0.75

    0.25

    1.00

    1.25

    1.50

    1.75

    2.00

    1.0

    5.0

    6.0

    7.0

    8.0

    4.0

    3.0

    2.0

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    20 40 60 80 100 120 140 160 180 200 220 240 260

    02

    04

    05

    09

    10

    07

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    48

    60

    43

    38

    20

    2226

    32

    17

    1512

    IE/25022700/00-2012

    Ø114.3

    [4.5

    ]

    Ø35 [1.3

    8] Ø

    15 [0.5

    9]

    6.4

    3 [0.2

    5]

    9.1 [0.36]

    11.8 [0.46]

    M5 n°2

    121.2 [4.77]8.4 [0.33]

    Ø98.32 [3.87]161.8 [6.37]

    90.4

    [3.5

    6]

    1/4-20UNC

    5-1

    6-1

    8U

    NC

    -2A

    mm [inches]

    24 VDC- 2.2 KW - D.115 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Performance with GR05 / GR1 pumps Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

    Voltage 24 VDCPower 2.2 kWNominal diameter 115 mm [4.53 in]

    Motor type Serie “U”(USA)Rotation CCWProtection class IP(with motor assembled on hydraulic power pack) 54

    S2 / S3 duty service see curvesInsulation class FWeight 6.7 kg [14.77 lb]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)02 0.25 05 22 2.2 104 0.45 05 26 2.6 105 0.56 05 32 3.2 107 0.75 05/1 38 3.8 109 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 117 1.7 120 2.0 1

    ®

  • 39

    25022700

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Amp

    bar

    psi0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

    200 40 60 80 100 120 140 160 180 200 220 240 260

    04

    05

    10

    09

    07

    02

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    60 48 43 38

    32

    22

    20

    12

    1715

    26

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

    S2

    S3

    IE/25022700/00-2012

    Current with GR05 / GR1 pumps Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev]

    Current with GR05 / GR1 pumps Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022700 24VDC motor - 2.2 kW

    25022900 24VDC motor - 2.2 kW with thermal swich

    Motor with thermal switch

    Code Description

    KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)

    ®

  • 40

    25021300

    138 [5.43]27.6 [1.09]

    6.5 [0.26] 12.5 [0.49]Ø110.5 [4.35]

    M6

    12 [0.47]

    43 [1.69] 207.5 [8.17]

    250.5 [9.86]

    22 [0.87]

    Ø1

    25

    [4

    .92

    ]

    Ø4

    2 [

    1.6

    5]

    Ø1

    29

    [5

    .08

    ]

    Ø5

    0 [

    1.9

    7]

    10

    2 [

    4.0

    2]

    Ø2

    4.2

    [0

    .95

    ]

    8 [

    0.3

    1]

    M5 n°2

    M8

    00

    1

    1.75

    2.00

    1.50

    1.25

    1.00

    0.75

    0.50

    0.25

    2.25

    2.50

    2

    10

    9

    8

    7

    6

    5

    4

    3

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    17

    20

    22

    12

    15

    10

    09

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    6.524

    26

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    26

    78

    60

    48

    43

    38

    63

    32

    IE/25021300/00-2012

    mm [inches]

    24 VDC - 3.0 KW - D.125 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Performance with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)09 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 122 2.2 126 2.6 132 3.2 138 3.8 1

    Voltage 24 VDCPower 3.0 kWNominal diameter 125 mm [4.92 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 20

    S2 / S3 duty service see curvesInsulation class FWeight 12 kg [26.46 lb]

    ®

  • 41

    25021300

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32

    26

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260

    0

    40

    20

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    22

    20

    17

    15

    12

    09

    10

    IE/25021300/00-2012

    Current with GR05 / GR1 pumps Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Current with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25021300 24VDC motor - 3.0 kW

    25023000 24VDC motor - 3.0 kW with thermal switch

    Code Description

    KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)

    Motor with thermal switch

    ®

  • 42

    00

    1

    1.75

    2.00

    1.50

    1.25

    1.00

    0.75

    0.50

    0.25

    2.25

    2.50

    2

    10

    9

    8

    7

    6

    5

    4

    3

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    17

    20

    22

    12

    15

    10

    09

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    6.524

    26

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    26

    78

    60

    48

    43

    38

    63

    32

    IE/25021300 FAN/00-2012

    M8

    A2

    E2

    D1

    E1

    193,9 [7.63]

    55.9 [2.2] 207,5 [8.17] Ø 110 [4.33]

    118 [4.65]

    133 [5.24]

    263,4 [10.37]

    Ø 1

    25 [4.9

    2]

    Ø50 [1.9

    7]

    Ø 1

    29 [5.0

    8]

    8 [0.3

    1]

    Ø 2

    0 [0.7

    9]

    5 [0.2

    ]

    133 [5.2

    4]

    118 [4.6

    5]

    M8

    X

    M5 n°2

    mm [inches]

    24 VDC - 3.0 KW - D.125 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Performance with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)09 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 122 2.2 126 2.6 132 3.2 138 3.8 1

    Voltage 24 VDCPower 3.0 kWNominal diameter 125 mm [4.92 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 20

    S2 / S3 duty service see curvesInsulation class FWeight 13.1 kg [28.88 lb]

    X = see ordering code

    25021300 FAN®

  • 43

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32

    26

    63

    0

    40

    20

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    22

    20

    17

    15

    12

    09

    10

    IE/25021300 FAN/00-2012

    S2

    S3

    0 0

    4

    8

    12

    4

    16

    8

    20

    12

    24

    16

    20

    24

    28

    32

    36

    40

    44

    48

    28

    32

    36

    40

    44

    48

    S2 (min) S3 (%)

    Amp100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260

    Current with GR05 / GR1 pumps Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Current with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    KIT07012.019 Starting switch kit 24VDC - 150A (fixing with clamp)Powerpack

    X mm [inch]

    Code Fan cooled

    motor

    Code Fan cooled

    motorwith thermal

    swich

    Code Fan cooled

    kit

    FP 53.2 [2.09] KIT09008.029 * 25017700

    MC 43.4 [1.71] KIT01008.118 KIT01008.119 25006100

    25021300 FAN

    Motor with thermal switch

    * please contact our sales department

    ®

  • 44

    25022400

    00

    1

    1.75

    2.00

    1.50

    1.25

    1.00

    0.75

    0.50

    0.25

    2.25

    2.50

    2

    10

    9

    8

    7

    6

    5

    4

    3

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    17

    20

    22

    12

    15

    10

    09

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    6.524

    26

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    26

    78

    60

    48

    43

    38

    63

    32

    IE/25022400/00-2012

    M5 n°2

    Ø 1

    25

    [4

    .92

    ]

    Ø 1

    29

    [5

    .08

    ]

    10

    2 [

    4.0

    2]

    Ø 5

    9 [

    2.3

    2]

    27,5 [1.08]

    131,5 [5.18]22 [0.87]

    6,5 [0.26] 11 [0.43]

    110,5 [4.35]

    M6

    M8

    12 [0.47]

    43 [1.69] 200 [7.87]

    243 [9.57]

    Ø 4

    2 [

    1.6

    5]

    24

    ,3 [

    0.9

    6]

    8 [

    0.3

    1]

    mm [inches]

    24 VDC - 3.0 KW - D.125 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Performance with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)09 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 122 2.2 126 2.6 132 3.2 138 3.8 1

    Voltage 24 VDCPower 3.0 kWNominal diameter 125 mm [4.92 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 20

    S2 / S3 duty service see curvesInsulation class FWeight 10,5 kg [23.15 lb]

    ®

  • 45

    25022400

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32

    26

    63

    S2

    S3

    0 0

    2 4

    4 8

    6 12

    8 16

    10 20

    12 24

    14 28

    16 32

    18 36

    20 40

    S2 (min) S3 (%)

    Amp60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260

    0

    40

    20

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    22

    20

    17

    15

    12

    09

    10

    IE/25022400/00-2012

    Current with GR05 / GR1 pumps Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Current with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    25022400 24VDC motor - 3.0 kW

    Code Description

    KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)

    ®

  • 46

    00

    1

    1.75

    2.00

    1.50

    1.25

    1.00

    0.75

    0.50

    0.25

    2.25

    2.50

    2

    10

    9

    8

    7

    6

    5

    4

    3

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    17

    20

    22

    12

    15

    10

    09

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    6.524

    26

    l/minUSgpm

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    26

    78

    60

    48

    43

    38

    63

    32

    IE/25022400 FAN/00-2012

    M8

    A2E

    2D

    1E

    1

    187,4 [7.38]

    55.9 [2.2] 200 [7.87] Ø 110 [4.33]

    118 [4.65]

    133 [5.24]

    255,9 [10.07]

    Ø 1

    25 [4.9

    2]

    Ø 5

    9 [2.3

    2]

    Ø 1

    29 [5.0

    8]

    8 [0.3

    1]

    Ø 2

    0 [0.7

    9]

    5 [0.2

    ]

    133 [5.2

    4]

    118 [4.6

    5]

    M8

    X

    M5 n°2

    mm [inches]

    24 VDC - 3.0 KW - D.125 MOTOR

    RATED FEATURES PUMP TYPE

    Performance with GR05 / GR1 pumpsDisplacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Performance with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Code cc/rev. GR (Size) Code cc/rev. GR (Size)09 0.9 05/1 43 4.3 110 1.0 05/1 48 4.8 112 1.2 05/1 60 6.0 115 1.5 1 63 6.3 117 1.7 1 78 7.8 120 2.0 122 2.2 126 2.6 132 3.2 138 3.8 1

    Voltage 24 VDCPower 3.0 kWNominal diameter 125 mm [4.92 in]

    Motor type Wound field compoundRotation CCWProtection class IP(with motor assembled on hydraulic power pack) 20

    S2 / S3 duty service see curvesInsulation class FWeight 11.6 kg [25.57 lb]

    X = see ordering code

    25022400 FAN®

  • 47

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    78 60 48 43 38 32

    26

    63

    0

    40

    20

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    Amp

    bar

    psi

    0

    0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200

    20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

    22

    20

    17

    15

    12

    09

    10

    IE/25022400 FAN/00-2012

    S2

    S3

    0 0

    4

    8

    12

    4

    16

    8

    20

    12

    24

    16

    20

    24

    28

    32

    36

    40

    44

    48

    28

    32

    36

    40

    44

    48

    S2 (min) S3 (%)

    Amp100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260

    Current with GR05 / GR1 pumps Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev]

    Current with GR1 pumps Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

    Thermal characteristics S2 - S3

    Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera-ture 35°C (viscosity 40 cSt), outside temperature 25°C.

    Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the terminals of the electric motor.

    ORDERING CODE

    Code Description

    KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)Powerpack

    X mm [inch]

    Code Fan cooled

    motor

    Code Fan cooled

    motorwith thermal

    swich

    Code Fan cooled

    kit

    FP 53.2 [2.09] * * 25017700

    MC 43.4 [1.71] * * 25006100

    25022400 FAN

    * please contact our sales department

    ®

  • 48IE/STARTING SWITCH/00-2012

    182,5 [3.25]

    Female Faston

    6.3-08 N.2

    64,5 [2.54]

    29 [1.15]

    Ø 5

    4.5

    [2.1

    5]

    26 [1.0

    2]

    M8 N

    .2

    5 [0.2]

    72 [2.83]

    Female Faston

    6.3-08 N.2

    57.3 [2.26]

    20 [0.79]

    Ø 4

    0 [

    1.5

    7]

    21

    [0

    .83

    ]

    M6

    N.2

    5 [0.2]

    mm [inches]

    mm [inches]

    RATED FEATURES

    Description 12 VDC 24 VDC

    Min cut-on voltage 8.4 V @ 20°C 11 V @ 60°C16.8 V @ 20°C 23 V @ 60°C

    Rated voltage 12 VDC 24 VDCCut off voltage 0.6 ÷ 4 VDC 1.2 ÷ 8 VDCCurrent consumption 1.9 ± 0.2 A 0.8 ± 0.1 AOperating temperature range -20 ÷ +60 °C -20 ÷ +60 °CVibration specification 9 g 9 gRated Current 120 A 120 ACoil short time duty S2 = 15 min S2 = 20 minProtection degree IP 67 IP 67Weight 290 gr [0.69 lb] 320 gr [0.71 lb]

    RATED FEATURES

    Description 24 VDC

    Min cut-on voltage 16.8 V @ 20°C 23 V @ 60°CRated voltage 24 VDCCut off voltage 1.2 ÷ 8 VDCCurrent consumption 1.1 ± 0.1 AOperating temperature range -30 ÷ +60 °CVibration specification 9 gRated Current 150 ACoil short time duty S3= 10% @ 350AProtection degree IP 54Weight 690 gr [1.52 lb]

    Wiring diagram

    Wiring diagram

    Starting switch: 120A

    Starting switch: 150A

    ORDERING CODE

    ORDERING CODE

    Motor type Code (12 VDC)Code

    (24 VDC)D. 80 fixing with clamp KIT07012.027 KIT07012.032D. 115 fixing with clamp KIT07012.033 KIT07012.034D. 115 fixing with screws KIT07012.025 KIT07012.026

    Motor type Code (24 VDC)D. 125 fixing with screws KIT07012.019

    ®

  • Dana Brevini Fluid Power S.p.A.Via Moscova, 642124 Reggio Emilia - ItalyTel. +39 0522 270711Fax +39 0522 270660www.dana.com/breviniinfo@brevinifl uidpower.com

    ®

    Code DOC00053 - Rev. 05