IEC 60870-5-101 Slave to PROFIBUS DP Master Gateway 5104-101S-PDPM
The 101S-PDPM modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a PROFIBUS slave device into a system. The IEC60870-5-101 Slave gateway is a powerful module designed with Slave support, enabling easy connection to an IEC 101 master device. In combination with the PROFIBUS DP Master support, the module provides a very powerful interface to the many PROFIBUS DP slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
DISCONTINUED IEC 60870-5-101 Slave to PROFIBUS DP Master Gateway 5104-101S-PDPM The ProLinx IEC60870-5-101 Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on an IEC 101 network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Master configurable DB9F port and one IEC 101 Slave configurable serial port.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in
the database • Protocol implementation conforms to the IEC 60870-
5-101 specification with fully configurable parameters
• Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
Latin America (Sales only) IEC 60870-5-101 Slave
+1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Configurable Parameters
Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time
Time DB Offset
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Communication parameters
PROFIBUS Master
Baud Rate: 9.6 kbit/s – 12 Mbit/s Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED
Serial Activity and Error LED Status
CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved
December 17, 2013.
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
IEC 60870-5-101 Slave to PROFIBUS DP Slave Gateway 5105-101S-PDPS
The 101S-PDPS modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a PROFIBUS DP master device into a system. The IEC60870-5-101 Slave gateway is a powerful module designed with Slave support, enabling easy connection to 101 master devices. IApplications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-101 Slave to PROFIBUS DP Slave Gateway 5105-101S-PDPS The ProLinx IEC60870-5-101 Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 101 network and a PROFIBUS DP master device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 101 Slave configurable serial port.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in the database • Protocol implementation conforms to the IEC 60870-5-101
specification with fully configurable parameters • Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave Configurable Parameters Data link address length
Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-101S-PDPS IEC 60870-5-101 Slave to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-103 Master to PROFIBUS DP Slave Gateway 5105-103M-PDPS
The 103M-PDPS modules are the ideal solution for the many applications where IEC 103 Master connectivity can be used to integrate a PROFIBUS DP master device into a system. The IEC60870-5-103 Master gateway is a powerful module designed with Master support, enabling easy connection to other IEC 103 slave devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-103 Master to PROFIBUS DP Slave Gateway 5105-103M-PDPS The ProLinx IEC60870-5-103 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 103 network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 103 Master configurable serial port.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters
Communication parameters Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master
Configurable Parameters Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-103M-PDPS IEC 60870-5-103 Master to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
IEC 60870-5-104 Server to IEC 60870-5-101 Master Gateway
5201-104S-101M
The ProLinx IEC 60870-5-104 Server to IEC 60870-5-101 Master Gateway creates a powerful connection between IEC 104 server devices on an Ethernet network and IEC 60870-5-101Master devices on a serial network. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one configurable IEC 101 Master serial port.
The ProLinx 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or event-driven data transmission. Firmware versions 3.00 and later support a wider range of IEC 60870-5-104 Edition 2 data types and Causes of Transmission than previously offered.
The ProLinx 101M driver can be configured to act as a IEC 60870-5-101 Master (controlling unit) communicating with IEC 60870-5-101 slaves (controlled units) on a serial communication network. The 101M driver supports polling of up to 16 slave devices, up to five sectors per slave, using up to 100 total polling commands.
Features Benefits
Powerful network integration
♦ Move data between dissimilar networks using two communication protocols on one gateway
♦ Protocols share access to a common memory database to exchange data between networks
♦ View diagnostic data for both networks from a single configuration/debug port
IEC 60870-5-104 Server protocol interface
♦ Adds an IEC 60870-5-104 Server (Slave) Input and Output link to an Ethernet network
♦ IEC 60870-5-104, Edition 2 Data Types and extended Cause of Transmission Support
♦ Advanced Event Buffer reporting controls allow better network data bandwidth utilization
IEC 60870-5-101 Master protocol interface
♦ Supports IEC 60870-5-101 Master specification: balanced/unbalanced mode, 16 sessions/5 sectors per session, timestamping
♦ Individually configurable serial application port
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics.
PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications - ProLinx
ProLinx® Communication gateways provide connectivity for two or more dissimilar
network types. The gateway, enclosed in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
General Specifications – 104 Server
Operating in Server mode (only), the 104S protocol implementation accepts commands from an IEC-60870-5-104 Client to read data stored in or write data into the gateway’s internal database memory registers. The 104S implementation is also capable of generating unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or cyclic (timing-driven) communication.
The remote Client device uses the fully-configurable gateway memory database to control outputs and monitor inputs to devices on the IEC 104 network. Changes to the gateway database can also be used to transfer monitoring and control data to devices connected to the gateway using another installed network protocol. The 104S gateway thus provides a data transfer solution between an IEC 60870-5-104 Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces.
General specifications include:
♦ User-definable database memory usage, based on data types and point counts
♦ Protocol implementation conforms to the IEC 60870-5-104 specification with fully-configurable parameters
♦ SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions (events)
General Specifications - 101 Master
The 101M module acts as an input/output module between the IEC 60870-5-101 network and many of the other serial and network protocols, as well as several proprietary interfaces. A 4000-word register space in the module exchanges data between the two protocols.
♦ Built in accordance to the approved international specification
♦ Support for the storage and transfer of up to 4000 registers between protocols
♦ User-definable module memory usage
♦ Configuration via a user-generated text file (downloadable to the module)
♦ Protocol implementation conforms to the IEC 60870-5-101 specification with fully configurable parameters
Schematic
Functional Specifications - IEC 60870-5-104 Server
IEC-60780-5-104 Server Functional Specifications Supported Message Types Accepts Client Monitor and Control Messages
Generates Timed Data Transmission Messages Generates Event Data Transmission Messages Supports all Edition 2 Causes of Transmission
Supported Data Types Monitor Points: M_SP_NA M_DP_NA M_ST_NA M_BO_NA M_ME_NA, NB, & NC M_IT_NA
Control Points: C_SC_NA C_DC_NA C_RC_NA C_BO_NA C_SE_NA, NB & NC
Maximum number of points (per Data Type)
500 Points for all Supported Data Types, except 50 Points for Types M_ME_NC and C_SE_NC 4000 total data words, maximum
Event Message Support Event Messages with or without Time Stamp Event Buffers up to 99 Events per Data Type Event Report Options: Latest Only or Multiple
Configurable Parameters Restricted IP Address Access List Supports "t0" Ethernet Connection Timeout Data Freeze Start and Freeze Interval Cyclic Data Transmission Time Data Type Priority Queues Data Validity Bit Checking and Timeout Control Bit Pulse On/Off Time And more...
Functional Specifications - IEC 60870-5-101 Master
The IEC 60870-5-101 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, and so on).
The gateway supports:
♦ 16 slaves (sessions with distinct Data Link Addresses)
♦ Each slave (session) supports up to 5 sectors (with distinct Common ASDU Addresses)
♦ Configurable General Interrogation messages during initialization
♦ Time comes from the 104S driver (remote host or NTP server)
♦ Supports General Interrogation, General Command and Time Synchronization Commands
General Parameters
Communication parameters Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2
Data Size: 5 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds
IEC 60870-5-101 Master
Configurable Parameters Baud Rate
Parity
RTS On
RTS Off
Minimum Delay
Receive Timeout
Data Link Address
Common ASDU Address
Where Automation Connects™
Global Distribution
We think like you do
ProSoft Technology® products are
distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support
We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices
We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology. com.
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications
Specification Description
Power Supply 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum
Operating Temperature -4°F to 122°F (-20°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Relative Humidity 5 to 95% (without condensation)
Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators
(On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port
(Ethernet protocol gateways only)
10Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s)
(Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals & Certifications
cULus ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cULus C22.2 No. 213-M1987
183151
Additional Products
ProSoft Technology® offers a full
complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information
To order this product, please use the following:
IEC 60870-5-104 Server to IEC 60870-5-101 Master Gateway
5201-104S-101M
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] fax to +33 (0) 5.61.78.40.52
Copyright © 2011 ProSoft Technology, Inc., all rights
reserved. April 7th, 2011
Specifications subject to change without notice.
IEC 60870-5-104 Server to IEC 60870-5-103 Master Gateway 5201-104S-103M
The 104S-103M modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate an IEC 103 slave device into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 client devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Electrical Power.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to IEC 60870-5-103 Master Gateway 5201-104S-103M The ProLinx IEC60870-5-104 Server to IEC60870-5-103 Master Gateway creates a powerful connection between devices on an IEC 104 network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters
Communication parameters Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master
Configurable Parameters Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-104S-103M IEC 60870-5-104 Server to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-104 Server to DF1 Master/Slave Gateway 5201/5202-104S-DFCM(4)
The 104S-DFCM modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DF1 Master/Slave devices into a system. The IEC60870-5-104 Server gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to DF1 Master/Slave Gateway 5201/5202-104S-DFCM(4) The ProLinx IEC60870-5-104 Server to DF1 Master/Slave Gateway creates a powerful connection between devices on an IEC 104 network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing
radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Specification Description Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH
x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-104S-DFCM 5202-104S-DFCM4
IEC 60870-5-104 Server to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-104 Server to DH-485 Gateway 5201-104S-DH485
The 104S-DH485 modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate a DH-485 device into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED
IEC 60870-5-104 Server to DH-485 Gateway
5201-104S-DH485 The ProLinx IEC60870-5-104 Server to DH-485 Gateway creates a powerful connection between devices on an IEC 104 Server network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on
change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in.
(13.2cmH x 6.934cmW x 11.48cmD)
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to
logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 16, 2013
IEC 60870-5-104 Server to DNP 3.0 Slave Gateway 5201-104S-DNPS
The 104S-DNPS modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DNP 3.0 DF1 Master or Slave devices into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to DNP 3.0 Slave Gateway 5201-104S-DNPS The ProLinx IEC60870-5-104 Server to DNP 3.0 Slave Gateway creates a powerful connection between devices on an IEC 104 Server network and a DNP master device. This stand-alone DIN-rail mounted protocol gateway provides one DNP 3.0 configurable serial port and one Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-104S-DNPS IEC 60870-5-104 Server to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway 5201-104S-DNPSNET
The 104S-DNPSNET modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DNP 3.0 DF1 Master or Slave devices into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DNP over Ethernet device support, the module provides a very powerful interface to the many DNP 3.0 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway 5201-104S-DNPSNET The ProLinx IEC60870-5-104 Server to DNP 3.0 over Ethernet creates a powerful connection between devices on an IEC 104 Server network and a DNP device. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-104S-DNPSNET IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-104 Server to Modbus Master/Slave Gateway 5201/5202-104S-MCM(4)
The 104S-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC 104 slave device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC60870-5-104 Server device support, the module provides a very powerful interface to the many IEC 104 client devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to Modbus Master/Slave Gateway 5201/5202-104S-MCM(4) The ProLinx IEC60870-5-104 Server to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and an IEC 104 client device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-104S-MCM 5202-104S-MCM4
IEC 60870-5-104 Server to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-104 Server to PROFIBUS DP Master Gateway 5204-104S-PDPM
The ProLinx IEC 60870-5-104 Server to PROFIBUS DP Master Gateways create a powerful connection between devices on an IEC 104 Server network and a PROFIBUS slave device. The module provides one Ethernet port and one PROFIBUS DP Master configurable DB-9F port.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED IEC 60870-5-104 Server to PROFIBUS DP Master Gateway
5204-104S-PDPM The IEC 60870-5-104 Server to PROFIBUS DP Master Gateway creates a powerful connection between devices on an IEC 104 network and a PROFIBUS DP slave. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Master configurable DB9F port and one IEC 104 Server Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-
5-104 specification with fully configurable parameters
• SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully- configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server Specification Description Configurable Parameters
Override StartDT Clear queue on close t1 timeout set value t2 timeout set value
Configuration Serial Port Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators
t3 timeout set value k (maximum queue) w (latest ack threshold)
Time DB Offset
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and
port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Communication Baud Rate: 9.6 kbit/s – 12 Mbit/s ProSoft Configuration Builder parameters PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs
Reset Cntrs Node address 0 - 125 – software selectable. Status Data Error codes, counters and port
status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED
Serial Activity and Error LED Status
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
IEC 60870-5-104 Server to
PROFIBUS DP Slave Gateway 5205-104S-PDPS
The IEC 60870-5-104 Server to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 104 network and PROFIBUS DP Master devices. This stand-alone DIN-rail mounted gateway provides one PROFIBUS DP-V0 Slave DB9F port and one IEC 104 Server Ethernet port.
The 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or event- driven data transmission. Firmware versions 3.00 and later support a wider range of IEC 60870-5-104 Edition 2 data types and Causes of Transmission than previously offered.
The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished using the provided ProSoft Configuration Builder software.
Features Benefits
Powerful network integration ♦ Move data between dissimilar networks using two communication protocols on one gateway ♦ Protocols share access to a common memory database to exchange data between networks ♦ View diagnostic data for both networks from a single configuration/debug port
IEC 60870-5-104 Server protocol interface
PROFIBUS DP-V0 Slave protocol interface
ProSoft Configuration Builder software included
♦ Adds an IEC 60870-5-104 Server (Slave) Input and Output link to a PROFIBUS DP network ♦ IEC 60870-5-104, Edition 2 Data Types and extended Cause of Transmission Support ♦ Advanced Event Buffer control parameters allow better data bandwidth utilization ♦ Adds PROFIBUS DP Slave device monitoring and control to a IEC 60870-5-104 network ♦ Easy configuration - GSD file provided ♦ PROFIBUS Slave status may be stored in gateway database and retrieval by either protocol ♦ Graphical drag-and-drop configuration tool for simple module configuration ♦ Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics ♦ View module database contents through serial connection to a desktop PC
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind ♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or
troubleshooting support helps you get going sooner and stay running longer ♦ Three-Year Warranty ensures reliability and protects against equipment failures
Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
General Specifications - 104S Server Operating in Server mode (only), the 104S protocol implementation accepts commands from an IEC-60870-5-104 Client to read data stored in or write data into the gateway’s internal database memory registers. The 104S implementation is also capable of generating unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or cyclic (timing-driven) communication.
The remote Client device uses the fully-configurable gateway memory database to control outputs and monitor inputs to devices on the IEC 104 network. Changes to the gateway database can also be used to transfer monitoring and control data to devices connected to the gateway using another installed network protocol. The 104S gateway thus provides a data transfer solution between an IEC 60870-5-104 Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces.
General specifications include:
• User-definable database memory usage, based on data types and point counts • Protocol implementation conforms to the IEC 60870-5-104 specification with fully-
configurable parameters • SNTP (Simple Network Time Protocol) time-stamping for detailed logging of data
transactions (events) General Specifications – PROFIBUS DP Slave The PROFIBUS DP-V0 Slave driver provides a powerful and easy-to-use interface between a PROFIBUS DP network and other networks. This slave implementation gives access to up to 244 bytes of PROFIBUS Input data and up to 244 bytes of PROFIBUS Output data, with a maximum configurable limit of 400 total data bytes. These Input and Output data areas are fixed in the ProLinx Gateway’s data memory, allowing the user to monitor or manipulate this data with either of the installed gateway protocols.
Functional Specifications
IEC-60780-5-104 Server Functional Specifications Supported Message Types Accepts Client Monitor and Control Messages
Generates Timed Data Transmission Messages Generates Event Data Transmission Messages Supports all Edition 2 Causes of Transmission
Where Automation Connects™ Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email. Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact
Supported Data Types Monitor Points: M_SP_NA M_DP_NA M_ST_NA M_BO_NA M_ME_NA, NB, & NC M_IT_NA
Control Points: C_SC_NA C_DC_NA C_RC_NA C_BO_NA C_SE_NA, NB & NC
information under distributor sales on the web site at:
www.prosoft-technology.com Whether your application is large or small, our technical professionals are there to help you choose the
Maximum number of points (per Data Type)
1000 Points for all Supported Data Types, except 50 Points for Types M_ME_NC and C_SE_NC 4000 total data words, maximum
right communication solution.
Event Message Support Event Messages with or without Time Stamp Event Buffers up to 99 Events per Data Type Event Report Options: Latest Only or Multiple
Configurable Parameters Restricted IP Address Access List Supports "t0" Ethernet Connection Timeout Data Freeze Start and Freeze Interval Cyclic Data Transmission Time Data Type Priority Queues Data Validity Bit Checking and Timeout Control Bit Pulse On/Off Time And more...
PROFIBUS DP Slave Functional Specifications GSD File PRLX05A5.GSD
Available on ProSoft Solutions DVD, or downloadable from ProSoft Technology® web site
Communication parameters Baud Rate: 9.6 kbps to 12 Mbps
Supported I/O length 244 bytes Input data 244 bytes Output data 400 total data bytes, maximum
Supported PROFIBUS DP-V0 features
Freeze Mode Sync Mode Auto Baud Setting
Additional Products
Configurable Parameters PROFIBUS Node Address: 0 to 125 Data byte swapping Action on loss of PROFIBUS connection Communication Fail Timeout Multiplier
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals
Current Load 500 mA max @ 32 VDC max
Operating Temperature -4° F to 122° F (-20° C to 50° C)
Storage Temperature -40° F to 185° F (-40 to 85° C)
Relative Humidity 5% to 95% (without condensation)
Dimensions Standard: 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 in H x 2.73 in W x 4.52 in D (13.2 cm H x 6.934 cm W x 11.48cm D)
ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: www.prosoft-technology.com
LED Indicators (On all gateways)
Configuration Serial Port
Ethernet Port (Ethernet protocol gateways only)
Application Serial Port(s) (Serial protocol gateways only)
Power & Hardware Fault Configuration & Application Communication Status Serial Configuration Port Activity and Error
DB-9M RS-232 only No hardware handshaking
10Base-T half-duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 sec, applied as specified in IEC 60950: Section 5.3.2, 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second for less than or equal to 5 minutes duration
RS-232/422/485 RS-232 handshaking configurable Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Copyright © 2015 ProSoft Technology, Inc.
All rights reserved. August 19, 2015
Serial Port Isolation 2500 V RMS port signal isolation per UL 1577 3000 VDC min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable ProSoft Solutions DVD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only)
Agency Approvals & Certifications UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D cUL C22.2 No. 213-M1987
Specifications subject to change without notice.
IEC 60870-5-104 Server to Rockwell Automation Remote I/O Gateway 5210-104S-RIO
The ProLinx IEC 60870-5-104 Server to Rockwell Automation Remote I/O Gateways create a powerful connection between devices on an IEC 104 Server network and Remote I/O devices. The module provides one Ethernet port and one Remote I/O port.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
IEC 60870-5-104 Server to Rockwell Automation Remote I/O Gateway 5210-104S-RIO The ProLinx IEC60870-5-104 Server to Rockwell Automation Remote I/O creates a powerful connection between devices on an IEC 104 network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5210-104S-RIO IEC 60870-5-104 Server to Rockwell Automation Remote I/O Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
EtherNet/IP™ to IEC 60870-5 104 Client Gateway
5201-DFNT-104C
The ProLinx EtherNet/IP™ to IEC 60870-5-104 Client gateway creates a powerful connection between an EtherNet/IP network and IEC 104 server devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port.
The EtherNet/IP protocol supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a server, the EtherNet/IP port is a very powerful data transfer tool.
The IEC 60870-5-104 client protocol implementation allows the transfer of monitored and control data to remote servers.
Features Benefits
Powerful network integration ♦ Allows movement of data between dissimilar networks using two communication protocols on one gateway
♦ Protocols share access to a common memory database to exchange data between networks
♦ View diagnostic data for both networks from a single configuration/debug port
EtherNet/IP Client and Server ♦ Integrate with widely available Rockwell Automation and 3rd party products and services worldwide
♦ Client/server Explicit Messaging communication supported
♦ 5 server connections
♦ 3 client connections supporting 100 communication commands per client
IEC60870-5-104 Client ♦ 4 connections for remote servers
♦ Supports up to 2 Common ASDU Addresses per server
♦ Supports monitored and control data
♦ Supports up 500 commands to the remote servers
♦ Timestamp events are available to the other protocol through the mailbox feature
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for management of gateway configuration files, as well as viewing communication and network diagnostics.
PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
General Specifications - ProLinx ProLinx Communication gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
General Specifications – IEC 60870-5-104C The ProLinx family EtherNet/IP to IEC 60870-5-104 Client communications module creates a powerful connection between an EtherNet/IP network and IEC 104 server devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Ethernet port.
General Specifications - EtherNet/IP™ The EtherNet/IP™ protocol is one of the primary connectivity tools used by different Rockwell Automation
® platforms.
♦ The Explicit Messaging aspect of the protocol has been implemented to provide asynchronous data transfer between the ProLinx gateway and Rockwell Automation hardware.
♦ Supported PLC Types PLC-2®, PLC-3
®, PLC-5
®, SLC™500, ControlLogix
®,
CompactLogix™, and MicroLogix™
♦ Messaging Types As a Client, PCCC Explicit Messaging
As a Server, PCCC or CIP Explicit Messaging
♦ Command Sets PLC-2/PLC-3/PLC5 Basic Command Set
PLC5 Binary Command Set
PLC5 ASCII Command Set
SLC500 Command Set
EtherNet/IP™ Server In server mode, the gateway accepts commands from one or more Clients to read/write data stored in the gateway’s internal registers.
Number of Connections 5 Supported PLC Types PLC2, PLC5, SLC and ControlLogix file types
supported
Internal Database Data Table File Size: 100 or 1000 words Data Table File Start: N10 to N109 (based on file size set to 100) or N10 to N19 (based on file set to 1000)
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP™ Client In Client mode, the gateway controls the read/write data transfer between the gateway and other EtherNet/IP devices.
Number of Clients Supported 1
Command List Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.
Polling of Command List User-configurable polling of commands, including disabled, continuous and on change of data (write only).
Other Configurable Parameters Number of Commands (up to 100 per Client)
Min Command Delay
Response Timeout
Retry Count
Command Error Pointer
Schematic
Functional Specifications - IEC 60870-5-104 Client
♦ Operating in the Client mode, the gateway generates commands to a server device to read/write data stored in the gateway's internal registers.
♦ The IEC 60870-5-104 Client communication protocol is built in accordance to the approved IEC specification.
♦ The gateway functions as a Client on the network supporting monitored and control data from IEC 60870-5-104 servers on the network.
♦ The gateway supports unsolicited messages, either cyclic or spontaneous.
♦ The gateway supports clock synchronization commands.
♦ The gateway supports Group interrogation (Global, General 1 to 16, Global Counters, Counters 1-4).
♦ The gateway supports up to 4 Client connections.
Supported Message Types Accepts Client Monitor and Control Messages
Supports all Edition 2 Causes of Transmission
Supported Data Types Monitor Points:
M_SP_NA
M_DP_NA
M_ST_NA
M_BO_NA
M_ME_NA, NB, NC
M_IT_NA
Control Points:
C_SC_NA
C_DC_NA
C_BO_NA
C_RC_NA
C_SE_NA, NB, NC
Maximum number of points (per Data Type)
1000 Points for all Supported Data Types, except
4000 total data words, maximum
Maximum number of commands 500 commands maximum for all four clients
Event Message Support Timestamp events are transferred to the other protocol through the mailbox feature.
Configurable Parameters t1 timeout set value
t2 timeout set value
t3 timeout set value
k (maximum queue)
w (latest ack threshold)
Where Automation Connects™
Global Distribution
We think like you do
ProSoft Technology® products are
distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support
We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices
We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology. com.
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications
Specification Description
Power Supply 24 Vdc nominal 18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum
Operating Temperature -4°F to 122°F (-20°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Relative Humidity 5% to 95% RH with no condensation
Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators
(On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port
(Ethernet protocol gateways only)
10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s)
(Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals and Certifications CB Safety
ATEX <Ex> II 3 G Ex nA IIC T4 X -20°C <= Ta <= 50°C
CE
cULus For Label & User Manual: <cULus> E183151 Class I Div 2 Groups A,B,C,D T6 -30°C <= Ta <= 60°C
E183151
Additional Products
ProSoft Technology® offers a full
complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information
To order this product, please use the following:
EtherNet/IP™ to IEC 60870-5-104 Client Gateway
5201-DFNT-104C
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] fax to +33 (0) 5.61.78.40.52
Copyright © 2011 ProSoft Technology, Inc., all rights
reserved. 5/25/2011
Specifications subject to change without notice.
DATASHEET
Modbus TCP/IP to PROFIBUS DPV1 Master SE Gateway
5204SE-MNET-PDPMV1
Automating integration for Schneider Electric® Modicon® processors and maximizing ease-of-use are the hallmark design criteria behind the new ProLinx® SE line of communication gateways. The first SE gateway, the 5204SE-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DP-V1 Master gateway, easily turns a Modicon M340™ or Quantum™ Programmable Automation Controllers (PAC) into a PROFIBUS DP-V1 Master. The new Application Communication Logic functions built into ProSoft Configuration Builder (PCB) automatically generate all the Unity™ Pro data types, variables, and logic required for the M340 or Quantum to perform PROFIBUS DP-V1 cyclic and acyclic communication.
PCB automatically generates customized export files based on the gateway's PROFIBUS DP network configuration. These files import into Unity Pro version 4 software without modification, eliminating the need to write additional communications message logic.
Automatically-generated Derived Function Block logic also provides advanced PROFIBUS DP-V1 acyclic message pass-through capability. Acyclic messaging allows access to extended slave data and diagnostics, as well as access to slave-specific special functions.
Whenever the PROFIBUS DP network configuration changes, new logic files can be automatically created, exported, and imported into an existing Unity Pro project, reducing engineering demands and cutting deployment time. Changes to the gateway's configuration can be password protected.
Features Benefits
New Application Communication Logic functions for use with Modicon M340 and Quantum PACs
♦ Designed specifically to enable a Modicon M340 or Quantum PAC using Modbus TCP/IP to act as a PROFIBUS DP-V1 Master
♦ Generates Unity Pro version 4.0 DFB logic and variable files from gateway configuration
♦ Automates the creation of application communication logic
♦ Ease-of-use means faster deployment, less engineering effort, fewer programming errors
Acyclic Pass-Through Capability ♦ Automatically generated DFBs enable advanced PROFIBUS DP-V1 acyclic messaging with minimal engineering and programming effort
♦ Acyclic messaging allows a M340 or Quantum PAC to communicate directly with PROFIBUS DP slaves, to access special slave features, and to get extended slave diagnostics and process data
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration ProSoft Configuration Builder (PCB), with new Application Communication Logic functions, provides a PC-based software configuration solution for managing gateway configuration files, viewing communication status, and monitoring network diagnostics, as well as password-protected configuration downloads. The 5204SE-MNET-PDPMV1 User Manual provides step-by-step instructions on how to move data from one network to the other.
General Specifications – ProLinx Gateways
ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
General Specifications - SE Modbus TCP/IP
The ProSoft Technology® special SE Modicon® Modbus TCP/IP implementation uses the gateway’s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and devices on other networks.
This special version of the protocol, the first of its kind, has been developed to add PROFIBUS DP-V1 Master capability to Modicon PACs using their native Modbus TCP/IP communications capabilities and Unity™ Pro version 4.0 programming software.
Modbus TCP/IP Server (Slave)
The Modbus TCP/IP (MNET) server driver in the 5204SE-MNET-PDPMV1 is a special adaptation of the standard ProSoft Technology MNET driver, enhanced with Application Communication Logic functions for Unity Pro version 4. This special driver accepts incoming connections on Service Port 502 for Clients using Modbus TCP/IP MBAP messages and from Clients on Service Port 2000 (or other Service Ports) for Clients using Encapsulated Modbus messages.
• Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination of data types throughout the 4000-register memory database for read requests from remote Modbus TCP/IP Clients
• The special version of the MNET server accepts write requests from remote Modbus TCP/IP Clients only when those requests write to register memory database addresses in the range specified for PROFIBUS Output data to be sent to slave devices on the PROFIBUS DP network
• Supports five independent server connections for Service Port 502 (MBAP)
• Supports five independent server connections for Service Port 2000 (Encapsulated)
• Modbus data types overlap in the gateway’s memory database, so the same data can be conveniently read or written as bit-level or register-level data
Modbus TCP/IP Client (Master)
• Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats
• Offers one Client connection with up to 100 commands to talk to multiple servers
Status Data
Error codes, counters, and port status available through automatically-created Application Communication Logic DFBs and variables
General Specifications - PDPMV1
The module supports Master specifications according to IEC 61158. Cyclic I/O data and acyclic message parameter data can be transferred with PROFIBUS DP-V1 Class 1 or Class 2 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DP-V0 or DP-V1 protocol.
Schematic
Functional Specifications - Modbus TCP/IP Modbus Commands Supported (Client and Server)
1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
Configurable Parameters: (Client and Server)
Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset
Configurable Parameters: Client Only
Minimum Command Delay Response Timeout Retry Count Command Error Pointer
Command List Up to 100 fully-configurable Client commands
Status Data Error codes reported individually for each command
Command List Polling Each command can be individually enabled or disabled; write-only-on-data-change is available
Functional Specifications - SE PROFIBUS DP-V1 Master Application Communication Logic functions in PCB automatically generate Unity Pro v4.0 DFB communication logic and variables for Modicon M340 and Quantum PAC systems from the PROFIBUS DP-V1 Master configuration
Easy-to-use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software
Project-unique GSD file import library
Automatic Bus Parameter calculation
Online slave diagnostics through PCB
Supports all standardized baud rates, up to 12 Mbps
Supports extended diagnostic data (DP-V1 only)
Auto baud detection at all valid PROFIBUS DP-V1 rates
CRC checksum determination of slave to processor configuration consistency
LED indicators for network Communication Status, Master Status, Token-Hold status, and Database (Configuration) Status
FDT/DTM PROFIBUS DP Master transport communication DTM software included (see PSW-CDTM-PDPM)
Up to 125 total slaves can be connected when using repeaters (up to 32 total nodes per network segment between repeaters)
Up to 1536 cyclic bytes input and 1536 bytes output data
Optically-isolated PROFIBUS DP interface with on-board DC-DC converter
Modbus TCP/IP pass-through of acyclic read and write messages (DP-V1 only)
Supports Sync and Freeze commands
Where Automation Connects™ Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology. com.
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20 H x 2.07 W x 4.52 D inches (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 H x 2.73 W x 4.52 D inches (13.2 cm H x 6.934 cm W x 11.48cm D)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s) (Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adaptor Note: The number of serial application ports depends on the module type, and the combination of protocols.
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only)
Agency Approval & Certification UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cUL C22.2 No. 213-M1987
243333 183151
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information To order this product, please use the following:
Modbus TCP/IP to PROFIBUS DPV1 Master SE Gateway 5204SE-MNET-PDPMV1
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2009. All Rights
Reserved. 12/22/2009
Specifications subject to change without notice.
'C' Programmable Application Development Module 5102-ADM4
The ProLinx Application Development Modules are the ideal solution for developing custom communication between your serial protocol networks and devices. Using the provided API, the module can be used as a bridge, a port splitter, or any of several other useful applications. Each port is individually programmable.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
'C' Programmable Application Development Module 5102-ADM4 The ProLinx 'C' Programmable Application Development Module provides a powerful platform for bridging communications between your custom serial protocols. This stand-alone DIN-rail mounted protocol gateway provides four fully programmable serial ports.
ADM The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module's hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API.
Applications for the ADM module may be developed using industry-standard DOS programming tools and the appropriate API components.
The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers.
Development Environment
• Operating system: General software DOS 6-XL • Compatible compiler (16-bit DOS target)
o Digital Mars C++ V8.49 (included) o Borland C++ V5.02
Application Programming Interfaces (API)
• Serial Port API: serial port functions • Backplane API: low level backplane functions • ADM API debug port functions: debug port functions,
database functions timer functions, high level backplane transfer functions, LED functions, flash read functions
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-ADM4 'C' Programmable Application Development Module
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
'C' Programmable over Ethernet Gateway 5201/5202-ADMNET(4)
The ProLinx Application Development Modules are the ideal solution for developing custom communication between your serial protocol networks and Ethernet devices. Using the provided API, the module can be used as a bridge, a port splitter, or any of several other useful applications. All application ports are individually programmable.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED 'C' Programmable over Ethernet Gateway
5201/5202-ADMNET(4) The ProLinx 'C' Programmable Gateway with Ethernet provides a powerful platform for bridging communications between your custom serial and Ethernet protocols. This stand-alone DIN-rail mounted protocol gateway provides either one or four fully programmable serial ports. The module provides one (ADMNET) or four (ADMNET4) serial ports, each individually configurable. ADMNET The ADM API Suite is provided to allow software developers access to the top layer of the serial ports. The ADMNET API suite accesses the Ethernet port.
Both APIs can be easily used without having detailed knowledge of the module's hardware design. The ADMNET API Suite consists of the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components.
General Protocol Specifications • Allows software developers to access
Serial/Ethernet ports without needing detailed knowledge of the module's hardware design
• API library functions are specified using the C programming language syntax
• Supports multi-threaded applications • The following compiler versions are compatible with
the MVI module API: o DigitalMars C++ V8.49 (included) o Borland C++ V5.02
• Operating System – General software DOS 6-XL • Flash ROM program space: 896 KB • RAM program and data space: 640 KB • Compact Flash socket: Up to 64 MB
ADM API Libraries Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention.
• Initialization – Open and close the API • Debug Port – Debug port user interface • Database – Read and write data to database
• Timer – Start and check timers • Backplane – Transfer data over the backplane • LED – Set user LED indicators • Flash – Parse configuration files • Miscellaneous – Configure the console
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED
Serial Activity and Error LED Status
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
'C' Programmable over Ethernet to Modbus Master/Slave Gateway 5201/5202-ADMNET(4)-MCM(4)
The ADMNET-MCM module is the ideal solution for many applications where Ethernet and serial connectivity need to be added to a Modbus Master/Slave platform. Example applications involving the ADMNET-MCM module include:
• Bar code scanner interface • Legacy ASCII protocol connections • Terminal port emulation • Printer driver (alarm/status printer) • Customized protocol implementations
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
'C' Programmable over Ethernet to Modbus Master/Slave Gateway 5201/5202-ADMNET(4)-MCM(4) The ProLinx 'C' Programmable Application Development Module with Ethernet to Modbus Master/Slave creates a powerful platform for developing and running 'C' applications to communicate with Modbus Master/Slave networks and devices. The module provides one (ADMNET-MCM) or four (ADMNET4-MCM4) serial ports, each individually configurable as a Modbus or custom Master or Slave.
ADMNET The ADM API Suite is provided to allow software developers access to the top layer of the serial ports. The ADMNET API suite accesses the Ethernet port.
Both APIs can be easily used without having detailed knowledge of the module's hardware design. The ADMNET API Suite consists of the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components.
General Protocol Specifications • Allows software developers to access Serial/Ethernet ports
without needing detailed knowledge of the module's hardware design
• API library functions are specified using the C programming language syntax
• Supports multi-threaded applications • The following compiler versions are compatible with the MVI
module API: o DigitalMars C++ V8.49 (included) o Borland C++ V5.02
• Operating System – General software DOS 6-XL • Flash ROM program space: 896 KB • RAM program and data space: 640 KB • Compact Flash socket: Up to 64 MB
ADM API Libraries Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention.
• Initialization – Open and close the API • Debug Port – Debug port user interface • Database – Read and write data to database • Timer – Start and check timers • Backplane – Transfer data over the backplane • LED – Set user LED indicators • Flash – Parse configuration files • Miscellaneous – Configure the console
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave
Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Specification Description
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-ADMNET-MCM 5202-ADMNET4-MCM4
'C' Programmable over Ethernet to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DISCONTINUED
'C' Programmable over Ethernet to Modbus TCP/IP Gateway
5201-ADMNET-MNET
The ProLinx® 'C' Programmable Application Development Module with Ethernet to Modbus TCP/IP creates a powerful platform for developing and running 'C' applications to communicate with Modbus TCP/IP networks and devices. The gateway provides one Ethernet port.
The ADMNET functionality allows the module to be programmed to accommodate devices with unique Ethernet protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real- time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers.
The Modbus TCP/IP protocol driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections. The driver recognizes both Modbus TCP/IP MBAP and Encapsulated Modbus messages.
Features Benefits
Powerful network integration ♦
♦
♦
Communicate between dissimilar networks
Shared database exchanges information from devices on both networks
View diagnostics between both networks
'C' Programmable over Ethernet ♦ Develop and deploy 'C' applications for a custom implementation, or to protect a proprietary algorithm
♦ Interface Modbus TCP/IP devices to Ethernet devices such as bar code scanners,
alarm/status printers, terminal port emulation, and legacy protocols
♦ Rapidly create specialized applications using a familiar programming language
Modbus TCP/IP protocol interface ♦ Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols
♦ Suitable for SCADA and "foreign device" interface applications
♦ Floating point data movement supported, including configurable support for Enron and Daniel® floating point applications
♦ Communicate with programmable controllers, intelligent devices, sensors and instruments
♦ Allows PCs and HMIs to monitor field devices
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or
troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total
solution to help you make our products fit your applications
Configuration The 'C' Programmable modules are completely configurable. The included API offers the option of text or binary configuration files, configuration through ladder logic, or hard- coded configuration within the application.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
'C' Programmable over Ethernet The ADMNET API is one component of the ProLinx ADM API Suite. The ADMNET API provides a simple module-level interface that is portable between members of the ProLinx Family. This is useful when developing an application that implements an Ethernet protocol for a particular device, such as a scale or bar code reader. After an application has been developed, it can be used on any of the ProLinx family modules.
Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components.
Development Environment • Operating system: General software DOS 6-XL • Compatible compiler (16-bit DOS target)
o Digital Mars C++ V8.49 (included) o Borland C++ V5.02
SDK Includes • ADM API LIB (library) File • ADM API Header File • Complete API Documentation • Image file creation utility • Image file download utility • DigitalMars 'C' compiler • General software DOS 6-XL • Example Code Files
Modbus TCP/IP ProSoft’s Modbus TCP/IP implementation uses the gateway’s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks.
Configurable floating point data movement is supported, including support for Enron or Daniel® floating point applications.
Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages..
• Supports five independent server connections for Service Port 502 (MBP) • Supports five independent server connections for Service Port 2000 (Encapsulated) • Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up
to 64,000 bits in any combination of data types throughout the memory database • Modbus data types overlap in the gateway’s memory database, so the same data
can be conveniently read or written as bit-level or register-level data.
Modbus TCP/IP Client (Master) • Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP
or Encapsulated Modbus message formats • Offers one client connection with up to 100 commands to talk to multiple severs
Status Data Error codes, counters, and port status available
Schematic
Functional Specifications 'C' Programmable over Ethernet Each API provides a library of function calls. This library supports any programming language that is compatible with the 'C' calling convention.
Initialization Open and close the API Debug
Port Debug port user interface
Database Read and write data to database
Timer Start and check timers
LED Set user LED indicators
Additional Products
®
Flash Parse configuration files ProSoft Technology offers a full
Modbus TCP/IP
complement of hardware and software solutions for a wide variety of industrial communication
Modbus Commands Supported (Client and Server)
1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers
6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple
platforms. For a complete list of products, visit
5: Force (Write) Single Coil Holding Registers our web site at: Configurable Parameters:
Gateway IP Address Modbus data type starting address offsets
www.prosoft-technology.com
(Client and Server) Floating point start address and database offset Configurable Parameters: Client Only
Minimum Command Delay Response Timeout Retry Count Command Error Pointer
Command List Up to 100 fully-configurable Client commands Status Data Error codes reported individually for each command Command List Polling Each command can be individually enabled or disabled;
write-only-on-data-change is available
Hardware Specifications Specification Description Power Supply 24 VDC nominal, 18 to 32 VDC allowed
Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x
11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status
Configuration Serial Port Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking 10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5
Copyright © ProSoft Technology, Inc. 2009-2013. All Rights Reserved. December 13, 2013
minutes duration Specifications subject to change without notice.
Shipped with Each Unit
Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility)
Agency Approval & Certification UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D cUL C22.2 No. 213-M1987
243333 183151
AppSrvCE Application Development Module 7000-ADM
The ProLinx 7000 series AppSrvCE Application Development Module is a highly flexible product that delivers programmability, communication protocols, and a powerful embedded historian. The module functionality is fully customizable and programmable using the EZ Design Studio software. Additionally, real-time data can easily be stored on the device using the integrated data historian. The AppSrvCE is the ideal solution for applications requiring custom 'C' programming, emissions monitoring and pharmaceutical manufacturing, or remote applications like utility RTUs, compressor monitoring and facilities monitoring.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
AppSrvCE Application Development Module 7000-ADM
Historian The AppSrvCE uses licensed software technology from OSIsoft to deliver an integrated data historian. The AppSrvCE can log real-time data at sub-second speed accessible using OSIsoft's PI product. Additionally, data can be accessed via an OPC HDA server. This historical data is ideal for sequence-of-event recording, process optimization and compliance reporting (FDA, EPA, etc.)
Features AppSrvCE is available with the following standard features. Additional and modified features are available.
• Supports all five IEC programming languages: Relay Ladder Logic, Sequential Function Chart, Function Block Diagram, Structured Text, and Instruction List
• 'C' for integration of custom code • Drag-and-drop/menu driven editors enable rapid
program development, reduce typing and syntax errors
• Object libraries make code reuse simple and efficient
• Easy debugging - Simulates code execution on the development station
• On-line monitoring with code selecting and real-time variable update
• Watch, Force I/O values and memory tags • Supports complex data structures:
o Three dimensional arrays o User defined structures
• Configuration tools for I/O drivers and communication protocols are managed from within EZ Design Studio. The multi-tasking execution engine allows for multiple tasks and priority levels including: o Cyclic tasks o Continuous task, background priority o I/O Sync task, execution sync. with I/O scan o Fault task, runs when a fault condition occurs o Start-up task, runs once prior to setting outputs
to initialize machine state
• AppSrvCE is an industrial platform with no rotating media
• Standard TCP/IP networking between the node and workstation enables:
o Remote program downloading o Remote monitoring o Remote node Start/Stop o Multi-node management
Module Features
Operating System
Microsoft Windows CE .NET.
Processor 300 MHz x 86 processor
Storage 32 Mbytes "Disk-on-a-Chip"
SDRAM 32 to 256 Mbytes
SRAM Battery-backed (512 Kbytes)
Timers (3) general purpose 16-bit , (1) Watchdog timer
IDE Interface Type I/II compact flash socket. Supports compact flash. IBM micro-drive, rotating media. Only Industrial Grade Compact Flash should be used.
Clock Battery-powered, real time
Software EZ Design Studio automation software for IEC 61131-3 programming
Protection DataSafe™ enabled, restores realtime data after a power failure
Status LEDs (9), 4 user defined, 5 system status
Standard PC Connections
USB Two USB 1.1 host interface ports. 1.5 and 12 Mbps. data rates
Ethernet Two Ethernet ports, both are 10/100 Base-T. IEEE 802.3 compliant, Category 5, RJ45 connectors
Serial Communi-cation
1- RS-232 port standard Add up to 5 additional RS-232, RS-422, RS-485 ports
Video Standard 15-pin VGA connector up to 1280x1024 (24-bit) display resolution
Protocols Serial and Ethernet protocols include Generic Serial, EtherNet/IP, Modbus RTU, Modbus ASCII and Modbus TCP/IP. Other protocols are available upon request
I/O Compatibility
Rockwell Automation
Rockwell Automation 1769 Compact I/O
Rockwell Automation 1794 Flex or 1795 Integra I/O
Custom Application Modules (CAMs)
Base model ships with a blank CAM. Other CAMs available at request.
Embedded High-performance I/O (optional)
Hardware Specifications
Temperature Operating: –20 to 60°C
Storage: -40 to 85°C
Mounting DIN-rail or panel mounting
Humidity 5% to 95% non-condensing
Vibration 10 to 500 Hz 2.0 G max. peak acceleration. 0.012 in (peak-to-peak) displacement
Shock Operating: 30 G peak for 11ms Storage: 50 G peak for 11ms
Weight 1.7 lbs. (771.107 g)
Power 10 to 24 VDC @ 0.25A
27 VDC max. User supplied.
Battery Lithium. Maintains a 30 day charge
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
7000-ADM AppSrvCE Application Development Module
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved. February 27, 2008
ASCII Generic Serial to PROFIBUS DP Slave Gateway 5105-ASCII-PDPS
The ASCII-PDPS modules are the ideal solution for the many applications where PROFIBUS DP Slave connectivity can be used to integrate an ASCII generic serial input device into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to a PROFIBUS master device. In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
ASCII Generic Serial to PROFIBUS DP Slave Gateway 5105-ASCII-PDPS The ProLinx ASCII Generic Serial to PROFIBUS DP Slave Gateway creates a powerful connection between a PROFIBUS DP master device and an ASCII input device. The module provides one PROFIBUS DP Slave port and one ASCII configurable serial port.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory
allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters
PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-ASCII-PDPS ASCII Generic Serial to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
BACnet/IP Client to PROFIBUS DP-V0 Slave Gateway
5205-BACNET-PDPS
The ProLinx® BACnet/IP Client to PROFIBUS DP-V0 Slave gateway creates a powerful connection between a PROFIBUS Master and BACnet/IP server devices. This stand-alone, DIN-rail-mounted, dual-protocol gateway provides a PROFIBUS Slave port and a BACnet/IP Client Ethernet port.
The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished, using the provided ProSoft Configuration Builder software.
The ProLinx BACnet/IP (Building Automation and Control networking) protocol implementation is designed specifically to meet the communication needs of building automation and control systems by providing limited BACnet/IP command support for such applications as heating, ventilating, and air-conditioning control, lighting control, access control, and fire detection systems.
Features Benefits
Powerful network integration ♦ Move data between dissimilar networks using two communication protocols on one gateway
♦ Protocols share access to a common memory database to exchange data between networks
♦ View diagnostic data for both networks from a single configuration/debug port
BACnet/IP Client ♦ Standard protocol for Building Automation and Control limited to Analog and Digital I/O commands
♦ Communicate with Building Automation controllers, HVAC, Fire and Safety equipment
♦ Support for Trane Building Control Unit (BCU)
PROFIBUS DP-V0 Slave ♦ Adds BACnet/IP device monitoring and control to a PROFIBUS DP network
♦ Easy configuration - GSD file provided
♦ 122 words input/122 words output, 200 words maximum I/O
Backed by ProSoft Technology ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics.
PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
General Specifications The ProLinx® Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
• Ethernet Configuration Port serves as a dual BACnet/IP Client application port • DIN to DB-9M serial port cable included per configurable serial port
BACnet/IP Client • The BACnet® driver supports a single UDP client to interface with one or more
devices that contain a BACnet/IP server • The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP
protocol primarily used with the Trane® BCU • The module controls the read/write data transfer between the gateway and other
BACnet/IP devices
PROFIBUS DP-V0 Slave • Input and Output data blocks are mapped by the user within the ProLinx module’s
data memory allowing the user maximum flexibility and data transfer with other protocols.
• A standard PRLX05A5.GSD file is provided on the Product CD • Baud rate communication parameters: 9.6 kbps to 12 Mbps • Status Data Error codes available on an individual command basis
Functional Specifications
BACnet/IP Client The BACnet/IP Client can be used to interface many different protocols with Ethernet-enabled BACnet devices. The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP protocol. Contact ProSoft Technology® Technical Support if you have any protocol compliance or functionality questions.
General One client
Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.
Service Port 1 to 65535
Function Code (limited) 12=Read Single Property 14=Read Multiple Properties 15=Write Single Property 16=Write Multiple Property
Data Type (limited) 0=Analog Input 1=Analog Output 3=Binary Input 4=Binary Output
Point Count 1 to 25
PROFIBUS DP-V0 Slave Slave configurable parameters PROFIBUS Node Address: 1 to 125
Data byte swapping Failsafe Action Communication Failure Mode
Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total
PROFIBUS DP-V0 Support Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Read/Write Mailbox Commands Commands allowing 1800 extended I/O data bytes
PROFIBUS DP to BACnetIP
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max @ 32 VDC max
Operating Temperature -4° F to 122° F (-20° C to 50°C)
Storage Temperature -40° F to 185° F (-40° C to 85°C)
Relative Humidity 5% to 95% (without condensation)
Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
BACnet/IP and Configuration Ethernet Port
10 Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
PROFIBUS Slave Port RS485, max. 12 MBit/s, isolated, EN 50170
Shipped with Each Unit Mini-DIN8-to-DB9M Adapter cable 6 ft RS232 null-modem configuration cable CD (docs and Configuration utility)
Agency Approvals & Certifications
UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cUL C22.2 No. 213-M1987
243333 183151
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information To order this product, please use the following:
BACnet/IP Client to PROFIBUS DP-V0 Slave Gateway 5205-BACNET-PDPS
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] fax to +33 (0) 5.61.78.40.52
Copyright © 2010 ProSoft Technology, Inc., all rights
reserved. 3/16/2010
Specifications subject to change without notice.
DF1 Master/Slave to IEC 60870-5-101 Slave Gateway 5102-DFCM3-101S
The DFCM-101S modules are the ideal solution for the many applications where IEC60870-5-101 Slave connectivity can be used to integrate DF1 Master/Slave devices into a system. The 101 gateway is a powerful module designed with Slave support, enabling easy connection to an IEC60870-5-101 Master device. In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to IEC 60870-5-101 Slave Gateway 5102-DFCM3-101S The ProLinx DF1 Master/Slave to IEC60870-5-101 Slave Gateway creates a powerful connection between devices on an IEC 101 network and DF1 devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one IEC 101 Slave configurable serial port and three DF1 Master or Slave configurable serial ports.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces. General specifications include: • User-definable module memory usage • Storage of IEC time used in module is available in the database • Protocol implementation conforms to the IEC 60870-5-101
specification with fully configurable parameters • Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave Configurable Parameters Data link address length
Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Specification Description Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DFCM3-101S DF1 Master/Slave to IEC 60870-5-101 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Master/Slave to IEC 60870-5-103 Master Gateway 5102-DFCM-103M
The DFCM-103M modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate IEC60870-5-103 devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC60870-5-103 device support, the module provides a very powerful interface to the many IEC60870-5-103 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to IEC 60870-5-103 Master Gateway 5102-DFCM-103M The ProLinx DF1 Master/Slave to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a DF1 network and IEC 103 slave devices. This stand-alone DIN-rail mounted protocol gateway provides two configurable serial ports.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters Communication parameters Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters Baud Rate
Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Specification Description Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DFCM-103M DF1 Master/Slave to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Master/Slave to ASCII Generic Serial Gateway 5102-DFCM-ASCII3
The DFCM-ASCII modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate ASCII serial input devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to ASCII Generic Serial Gateway 5102-DFCM-ASCII3 The ProLinx DF1 to ASCII Generic Serial Gateway creates a powerful connection between devices on a DF1 network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides one DF1 configurable serial port and three ASCII configurable serial ports.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex – Slave (not peer mode) Half Duplex – Polled
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DFCM-ASCII3 DF1 Master/Slave to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Master/Slave to Honeywell DE Master Gateway 5106-DFCM-DEM
The DFCM-DEM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate Honeywell DE devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE device support, the module provides a very powerful interface to the many Honeywell DE devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to Honeywell DE Master Gateway 5106/5126-DFCM-DEM(2) The ProLinx DF1 Master/Slave to Honeywell DE Master Gateway creates a powerful connection between devices on a DF1 network and Honeywell DE devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and eight Honeywell DE channels.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
DE Communications • Built in accordance with the Honeywell DE specification • Supports up to 8 single PV transmitters, 2 multivariable
transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal Assembly (FTA)
with ProSoft-supplied cable • Supports redundant and non-redundant FTA implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
LEDs for Visual Module Status
DE Active DE Error
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5106-DFCM-DEM DF1 Master/Slave to Honeywell DE Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Master/Slave to HART Multi-drop Gateway 5107/5127-DFCM-HART(2) The DFCM-HART modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate HART devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Hart device
DISCONTINUED DF1 Master/Slave to HART Multi-drop Gateway 5107/5127-DFCM-HART(2) The ProLinx DF1 Master/Slave to HART Multi-drop Gateway creates a powerful connection between devices on a DF1 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight HART channels. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters
support, the module provides a very powerful interface to the many HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected]
Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing radio,
smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates commands)
Half-Duplex – Polling Command List Up to 100 commands per Master port, each fully-
configurable for function, slave address, register to/from addressing and word/bit count
+1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Polling of Command List
User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words)
port Data Table location in database (0 to 3999)
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
Specification Description Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL
1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
HART Driver Command List Up to 100 fully configurable commands per
channel Polling of command list User configurable polling of commands,
including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products. Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved. December 17, 2013
The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol
gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature 0 to 50°C (32 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet RJ45 Connector modules only) Link and Activity LED indicators
DISCONTINUED DF1 Master/Slave to
HART Analog Gateway 5108-DFCM-HART / 5128-DFCM-HART
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 milliseconds
DF1 Master/Slave to HART Analog Gateway 5108-DFCM-HART / 5128-DFCM-HART
The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a DF1 network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.
Error Checking BCC and CRC
Miscellaneous Full hardware handshaking control, providing radio, smart modem and multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex - Master (Module generates commands)
Half-Duplex - Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List
User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications Isolated HART Analog Input Specifications
The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in
Open circuit detection time
1/2 second maximum
slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's
Over current +/-40mA continuous, maximum
internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex - Slave (not peer mode)
Common Mode Noise Rejection
Calibrated Accuracy @ 25°C
105dB
4 to 20 mA: 0.05% of reading
Configurable parameters per slave port
HART Analog
Half Duplex - Polled
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated
24V DC Isolation Voltage 1500 VDC
HART® is a registered trademark of the HART Communication Foundation
Configuration ProSoft Configuration Builder (PCB) provides a quick
The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications The ProLinx® Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Communication parameters
Configurable Parameters per Channel
HART Driver
Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
Hardware Specifications Specification Description
Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 1-4 ch: 190 mA max@ 32 VDC max 5-8 ch: 250 mA max@ 32 VDC max
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write
Operating Temperature
Storage Temperature
-20 to 50°C (-4 to 122°F)
-40 to 85°C (-40 to 185°F)
only) and dynamically user or automatic enabled.
Isolated HART Analog Input Specifications
Input Range Current: 4 to 20mA with HART
Resolution 16bits
Input Filter First Order Sync: 10 Hz
Current Input Resistance 247.6 ohms +/- 1%
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status HART Channel Activity (Green)
Specification Description
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specifications are subject to change without notice.
Copyright © ProSoft Technology, Inc. 2013. All Rights Reserved. December 17, 2013
HART Interface Four or eight HART Point-to-Point
channels (5x08 = 4 inputs; 5x28 = 8 inputs)
Screw terminals for each channel
Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Common Mode Rejection
105db @ DC
Over current +/- 40mA continuous, maximum
Overvoltage Protection
All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection
Accuracy 4 to 20 mA: 0.05% of reading @ 25°C
24VDC loop output power
Shipped with Each Unit
1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector
Certifications CE and ATEX
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Compatible products in this product line also include:
EtherNet/IP to HART Analog Gateway
(5208-DFNT-HART / 5228-DFNT-HART)
Modbus TCP/IP to HART Analog Gateway
(5208-MNET-HART / 5228-MNET-HART)
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
DF1 Master/Slave to PROFIBUS DP Master Gateway 5104-DFCM-PDPM
The DFCM-PDPM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus Master/Slave gateway is a powerful module designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to PROFIBUS DP Master Gateway 5104-DFCM-PDPM The ProLinx DF1 Master Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DF1 network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DP Master port.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex – Slave (not peer mode) Half Duplex – Polled
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable. Status Data Error codes, counters and port status
available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5104-DFCM-PDPM DF1 Master/Slave to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Master/Slave to PROFIBUS DP Slave Gateway 5105-DFCM-PDPS
The DFCM-PDPS modules are the ideal solution for the many applications where PROFIBUS connectivity can be used to integrate DF1 devices into a system. The PROFIBUS DP Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Master/Slave to PROFIBUS DP Slave Gateway 5105-DFCM-PDPS The ProLinx DF1 Master/Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a PROFIBUS DP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS DP Slave.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-DFCM-PDPS DF1 Master/Slave to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to IEC 60870-5-101 Slave Gateway 5201-DFNT-101S
The DFNT-101S modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate an IEC 101 master device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 101 Slave device support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to IEC 60870-5-101 Slave Gateway 5201-DFNT-101S The ProLinx EtherNet/IP to IEC60870-5-101S Gateway creates a powerful connection between devices on an EtherNet/IP network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 101 Slave configurable serial port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in the database • Protocol implementation conforms to the IEC 60870-5-101
specification with fully configurable parameters • Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave Configurable Parameters Data link address length
Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature 0 to 50°C (32 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-101S EtherNet/IP to IEC 60870-5-101 Slave Gateway
Note: The 5201-DFNT-101S is in a Final Sales Period of two years, effective October 14, 2008 until October 14, 2010. Thereafter, the product will continue to be supported until October 14, 2014. The recommended replacement product is the 5102-DFCM3-101S DF1 Master/Slave to IEC 101 Slave Communication Gateway.
For more information on the Product Retirement Program, please visit: http://www.prosoft-technology.com/products/product_retirement_program
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to IEC 60870-5-103 Master Gateway 5201-DFNT-103M
The DFNT-103M modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate an IEC 103 slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to IEC 60870-5-103 Master Gateway 5201-DFNT-103M The ProLinx EtherNet/IP to IEC60870-5-103 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications Polling of command list User configurable polling of commands,
including disabled, continuous and on change of data (write only).
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters Communication parameters Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters Baud Rate
Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-103M EtherNet/IP to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to IEC 60870-5-104 Server Gateway 5201-DFNT-104S
The DFNT-104S modules are the ideal solution for joining EtherNet/IP and IEC60870-5-104 Server networks. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 104 Server device support, the module provides a very powerful interface to the many IEC 104 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to IEC 60870-5-104 Server Gateway 5201-DFNT-104S The ProLinx EtherNet/IP to IEC60870-5-104 Server Gateway creates a powerful connection between an EtherNet/IP network and IEC 104 client devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include: • User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-104S EtherNet/IP to IEC 60870-5-104 Server Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to ASCII Generic Serial Gateway 5201/5202-DFNT-ASCII(4)
The DFNT-ASCII modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate ASCII serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to ASCII Generic Serial Gateway 5201/5202-DFNT-ASCII(4) The ProLinx EtherNet/IP to ASCII Generic Serial Gateway creates a powerful connection between devices on an EtherNet/IP network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port and up to four ASCII configurable serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-ASCII 5202-DFNT-ASCII4
EtherNet/IP to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to BOSCH Packaging Machinery Gateway 5201/5202-DFNT-BSCH(4)
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc).
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to BOSCH Packaging Machinery Gateway 5201/5202-DFNT-BSCH(4) The ProLinx EtherNet/IP to BOSCH Packaging Machinery Gateway creates a powerful connection between devices on an EtherNet/IP network and BOSCH packaging machinery. The module provides a single Ethernet port and up to four BOSCH configurable serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The BOSCH Master protocol driver supports Master implementations of the protocol on up to four ports. Each of the ports is individually configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
BOSCH Packaging Machinery The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc).
General Parameters Type Specifications
Internal Database 4000 registers (words) available BOSCH Modes Full-Duplex Error Checking BCC
BOSCH Master Driver Type Specifications General Full-Duplex, Point to Point Configurable Parameters per Master port
Min Command Delay, Number of Commands, Response Timeout, Retry Count, Slave List Error Pointer
BOSCH Commands supported
0x00 Protected Write 0x01 Unprotected Read
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-BSCH 5202-DFNT-BSCH4
EtherNet/IP to BOSCH Packaging Machinery Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
EtherNet/IP to CC-Link Local & Intelligent Station Gateway
5209-DFNT-CCLINK
ProSoft Technology's EtherNet/IP® to CC-Link communication gateway allows Rockwell Automation® control platform users to integrate CC-Link Master compatible products with existing EtherNet/IP control networks.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol and is user-configurable as both a Client and/or a Server. As a Client, the gateway can send commands and manage data flow among a large number of devices on the EtherNet/IP network. As a Server, the gateway can provide concurrent data transfer to multiple Clients.
The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.
Features Benefits Powerful network integration ♦ Communicate between dissimilar networks
♦ A shared, 10,000-word database exchanges information from devices on both networks
♦ Allows integration of EtherNet/IP-based systems onto a CC-Link Master-controlled network
EtherNet/IP ♦ Client/Server Explicit Messaging communication supported
♦ Allows up to five concurrent Server connections from multiple network Clients
♦ Provides three concurrent Client connections, supporting up to 100 commands per Client
CC-Link Intelligent or Local Station
♦ Compatible with CC-Link Version 1.10
♦ Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity
♦ Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station
♦ As a Local Station, provides a read-only list of all network slaves’ cyclic and status data
♦ CC-Link Partner Association (CLPA) Certification
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools used by different Rockwell Automation® platforms.
♦ The Explicit Messaging aspect of the protocol has been implemented to provide asynchronous data transfer between the ProLinx gateway and Rockwell Automation hardware.
♦ Supported PLC Types PLC-2®, PLC-3®, PLC-5®, SLC™500, ControlLogix™, CompactLogix™, and MicroLogix™
♦ Messaging Types As a Client, PCCC Explicit Messaging As a Server, PCCC or CIP Explicit Messaging
♦ Command Sets PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set
CC-Link CC-Link (Control & Communication Link) is an open-standard-based communication protocol that enables easy connection to Mitsubishi and other Master PLCs.
♦ CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide.
♦ The ProLinx CC-Link interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer.
♦ The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector.
Functional Specifications
EtherNet/IP Server In Server mode, the gateway accepts messages from one or more Clients that want to read data from or write data to the gateway's internal memory database.
Miscellaneous Binary, Integer or Floating point data supported, as well as other special data types, like timers, counters, ASCII files and more
EtherNet/IP Server Five independent TCP/IP Server sockets permit multiple Clients to see and change all user data contained in the gateway. The Server supports CIP and PCCC Explicit Message connections from EtherNet/IP Clients.
PCCC Data File Emulation (the Server looks like an SLC 5/05 to the Clients)
Data Table File Size: 100 or 1000 words Data Table File Start: - Fixed at N10 Data Table Range: N10 to N109, based on file size set to 100, or N10 to N19, based on file set to 1000 (Other data table types also supported)
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
Schematic
EtherNet/IP Client
In Client mode, the gateway controls read and write data transfers between the itself and other EtherNet/IP devices. Data transfer can be initiated and executed with no logic programming required in the target Rockwell Automation hardware.
EtherNet/IP Client Three simultaneous Client connections
Command List Each Client supports up to 100 read or write commands per Client, allowing up to three concurrent connections with Ethernet/IP devices.
Command Poll List User can enable or disable polling on a per-command basis, as well as choose to write continuously or only on change of data.
Configurable Parameters Number of commands (Up to 100 per client) Min Command Delay Response Timeout Retry Count (and much more)
CC-Link
CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing it's I/O data transfer capacity.
Maximum Number of Occupied Stations
4 stations, consecutive addresses
Maximum Number of Devices per Network
26-64 Devices depending on Local and Slave Stations configured
Device Types Supported Intelligent Device and Local Station
CC-Link Version supported CC-Link Version 1.10 cyclic data transmission
Message handling Cyclic Messages and Transient Messages
Cyclic Data Capacity 24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave
Additional I/O Data Transfer Capacity
Transient Messaging extends I/O data transfer capacity by more than 8,000 additional words
Transient Message Commands
System Information, Memory Access Information, RUN, STOP, Line Test, Memory Read, and Memory Write commands
Communication speed 10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps
Transmission path format Bus format (EIA RS485 conformance)
Transmission format HDLC conformance
Error control system CRC (X16+X12+X5+1)
Conformance Testing
Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.
Where Automation Connects Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at www.prosoft-technology. com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, and Ground terminals 2.5 mm screwdriver blade-sized terminals
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
General LED Indicators Power and General Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
CC-Link LED Indicators Run (Network Status) L Run (Data Link Execution) L Err (Data Link Comm Error) SD (Sending Data LED) RD (Receiving Data LED) ERR (Switch Setting Error)
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
CC-Link Interface Pin Description
DA Data Communication line A
DB Data Communication line B
DG Digital Ground
SLD Shield
FG Frame Ground
Shipped with Each Unit Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) CC-Link to Terminal Block connector
Agency Approval & Certification ISA
CC-Link Partner Association
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor.
EtherNet/IP to CC-Link Local Station & Intelligent Device Gateway 5209-DFNT-CCLINK
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to http://www.prosoft-technology.com
Distributors:
Place your order by email or fax to:
North American / Latin American / Asia Pacific
[email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2013. All
Rights Reserved. 11/7/2013
Specifications subject to change without notice.
EtherNet/IP to Command Language Master Gateway 5201/5202-DFNT-CLVM(4)
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). The CLV Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the CLV protocol (Master, Error Checking, Baud rate, etc).
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to Command Language Master Gateway 5201/5202-DFNT-CLVM(4) The ProLinx EtherNet/IP to Command Language Master Gateway creates a powerful connection between devices on an EtherNet/IP network and SICK barcode scanners. The module provides a single Ethernet port and up to four CLV Master configurable serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
CLV Master The CLV Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the CLV protocol (Master, Error Checking, Baud rate, etc).
General Specifications
Ports One to four ports to receive and/or transmit data
Receive buffer size 255 bytes Receive termination Termination character Receive database location 1 to 3896
Communication Configuration
Baud Rates 110 to 115,200 Parity None, Odd, Even Data Bits 5 to 8 Stop Bits 1 or 2 RTS On and Off Timing 0 to 65535 milliseconds Minimum Response Delay 0 to 65535 milliseconds Hardware Handshaking RTS/CTS Supports device type of CLV 41X, V1.10 H757 to V1.30 I415
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-CLVM 5202-DFNT-CLVM4
EtherNet/IP to Command Language Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to Honeywell DE Master Gateway 5206-DFNT-DEM
The DFNT-DEM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate Honeywell DE slave devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED
EtherNet/IP to Honeywell DE Master Gateway
5206-DFNT-DEM The ProLinx EtherNet/IP to Honeywell DE Master Gateway creates a powerful connection between devices on an EtherNet/IP network and Honeywell DE slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and eight Honeywell DE Master channels.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED
Serial Activity and Error LED Status Configuration Serial Port DB-9M RS-232 only
No hardware handshaking Polling of command list User configurable polling of commands,
including disabled, continuous and on Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
change of data (write only).
Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
DE Communications • Built in accordance with the Honeywell DE specification • Supports up to 8 single PV transmitters, 2 multivariable
transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal Assembly (FTA)
with ProSoft-supplied cable • Supports redundant and non-redundant FTA implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and
LEDs for Visual Module Status
DE Active DE Error
software solutions for a wide variety of industrial communication platforms.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in.
(13.2cmH x 6.934cmW x 11.48cmD)
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
EtherNet/IP to DF1 Master/Slave Gateway 5201/5202-DFNT-DFCM(4)
The DFNT-DFCM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DF1 devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to DF1 Master/Slave Gateway 5201/5202-DFNT-DFCM(4) The ProLinx EtherNet/IP to DF1 Master/Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each configurable
for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing
radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Specification Description Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-DFCM 5202-DFNT-DFCM4
EtherNet/IP to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to DH-485 Gateway 5201-DFNT-DH485
The DH485-DFNT modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a DH-485 device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to DH-485 Gateway 5201-DFNT-DH485 The ProLinx EtherNet/IP to DH-485 Gateway creates a powerful connection between devices on EtherNet/IP and DH-485 networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one DH-485 configurable serial port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-DH485 EtherNet/IP to DH-485 Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to DNP 3.0 Master Gateway 5201-DFNT-DNPM
The DFNT-DNPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DNP 3.0 Master serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP Master device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to DNP 3.0 Master Gateway 5201-DFNT-DNPM The ProLinx EtherNet/IP to DNP 3.0 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and DNP Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2 DNP Object Support DNPM Driver Manual contains full Object
Definition documentation
DNP Master
Node address 0 to 65534 – software selectable Slave count Up to 40 slave devices Command count Up to 300 user defined commands to
interface with remote slave devices
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-DNPM EtherNet/IP to DNP 3.0 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to DNP 3.0 Slave Gateway 5201-DFNT-DNPS
The DFNT-DNPS modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DNP 3.0 Slave devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to DNP 3.0 Slave Gateway 5201-DFNT-DNPS The ProLinx EtherNet/IP to DNP 3.0 Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and DNP master devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-DNPS EtherNet/IP to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to DNP 3.0 over Ethernet Gateway 5201-DFNT-DNPSNET
The DFNT-DNPSNET modules are the ideal solution for joining EtherNet/IP and DNP over Ethernet networks. This Ethernet to Ethernet gateway is a powerful module designed with both Client and Server support for each protocol, enabling easy connections between the dissimilar network types. The module utilizes a shared database so that the two protocols can quickly and easily transfer data between themselves. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to DNP 3.0 over Ethernet Gateway
5201-DFNT-DNPSNET The ProLinx EtherNet/IP to DNP over Ethernet Gateway creates a powerful connection between devices on EtherNet/IP and DNP over Ethernet networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Specification Description
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-DNPSNET EtherNet/IP to DNP 3.0 over Ethernet Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to GE Ethernet Global Data Gateway 5201-DFNT-EGD
The DFNT-EGD modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). In combination with the GE Ethernet Global Data device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to GE Ethernet Global Data Gateway 5201-DFNT-EGD The ProLinx EtherNet/IP to GE Ethernet Global Data Gateway creates a powerful connection between EtherNet/IP and GE Ethernet Global Data networks. The module provides one Ethernet port. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common. This common database provides the "backbone" communications for various field devices using different networks
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client Specifications General One client
Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
EGD GE Fanuc Automation and GE Drive Systems developed an Ethernet Global Data, or EGD, exchange for PLC and computer data in 1998. GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume. The module supports the following functions specified in the EGD protocol: Code Description 3 Retrieve Configuration Request (example provided)
4 Retrieve Configuration Response (example provided)
7 Summary Request
8 Summary Response
9 Capabilities Request
10 Capabilities Request
15 Statistics Request
16 Statistics Response
18 Command NAK
32 Read Request
33 Read Response
34 Write Request
35 Write Response
36 Masked Write Request
37 Masked Write Response
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification DescriptionPower Supply 24 VDC nominal
18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification DescriptionLED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5201-DFNT-EGD EtherNet/IP to GE Ethernet Global Data Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2014. All Rights Reserved.
April 29, 2014
EtherNet/IP to Garvens Remote Control Checkweigher Gateway 5201/5202-DFNT-GRCM(4)
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol has been implemented in the ProLinx units to providethe data transfer link between the ProLinx units and Rockwell Automation hardware. (Implicit Messaging - connected I/O communications - is not supported). The GRCM driver permits the module to interface Garvens Checkweighers using Garvens Remote Control (GARECO) serial protocol with EtherNet/IP devices. The gateways provides one or four serial ports that allow connection of one to four GARECO serial devices, one per port.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to Garvens Remote Control Checkweigher Gateway 5201/5202-DFNT-GRCM(4) The ProLinx EtherNet/IP to Garvens Remote Control Checkweigher Gateway creates a powerful connection between devices on an EtherNet/IP network and Garvens high speed checkweighers. The module provides a single Ethernet port and up to four configurable serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
GARECO Protocol for Hi-Speed Checkweigher The GRCM driver permits the gateway to interface checkweighers using Garvens Remote Control serial protocol to Rockwell Automation®EtherNet/IP™ devices over Ethernet. The 5201 has one GARECO serial port and the 5202 has four GARECO serial ports to providecommunication access for one GARECO serial device per port.
General Specifications
Ports One to four ports to receive and/or transmit data; One GARECO device allowed per port
Receive Buffer Size 255 bytes Receive Termination Termination character Receive Database Location
0 to 7000
Supports device types of Topline VS/VO, "S" Series, and "E" Series
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-GRCM 5202-DFNT-GRCM4
EtherNet/IP to GARECO Protocol for Hi-Speed Checkweigher Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to HART Multi-drop Gateway 5207-DFNT-HART
The DFNT-HART modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate HART Multi-drop devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to HART Multi-drop Gateway 5207-DFNT-HART The ProLinx EtherNet/IP to HART Multi-drop gateways create a powerful connection between devices on an EtherNet/IP network and HART Multi-drop devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and four HART Multi-drop channels. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver Command List Up to 100 fully configurable commands per
channel Polling of command list User configurable polling of commands,
including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max Operating Temperature -20 to 50°C (-4 to 122°F) Storage Temperature -40 to 85°C (-40 to 185°F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status HART Channel Activity (Green)
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
HART Interface Four (4) HART Multi-drop channels Screw terminals for each channel
24VDC power Screw terminal for 24VDC Provides HART loop power
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) HART Terminal Block connector
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5207-DFNT-HART EtherNet/IP to HART Multi-drop Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved. February 08, 2008
EtherNet/IP to HART Analog Gateway 5208-DFNT-HART / 5228-DFNT-HART
The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on an EtherNet/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.
DATASHEET
EtherNet/IP to HART Analog Gateway
5208-DFNT-HART / 5228-DFNT-HART
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx® units to provide the data transfer link between the ProLinx units and the Rockwell Automation® hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengthsFloating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
CIP Services Supported
0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client
Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
HART Analog The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
Communication parameters
Number of HART Preambles: 2 to 50Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
Isolated HART Analog Input Specifications
Input Range Current: 4 to 20mA with HART
Resolution 16bits
Input Filter First Order Sync: 10 Hz
Current Input Resistance 247.6 ohms +/- 1%
Open circuit detection time
1/2 second maximum
Over current +/-40mA continuous, maximum
Common Mode Noise Rejection
105dB
Isolated HART Analog Input Specifications
Calibrated Accuracy @ 25°C
4 to 20 mA: 0.05% of reading
Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated
24V DC Isolation Voltage 1500 VDC
HART® is a registered trademark of the HART Communication Foundation
Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications The ProLinx® Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 1-4 ch: 190 mA max@ 32 VDC max 5-8 ch: 250 mA max@ 32 VDC max
Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status HART Channel Activity (Green)
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
HART Interface Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel
Specification Description
Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Common Mode Rejection
105db @ DC
Over current +/- 40mA continuous, maximum
Overvoltage Protection
All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection
Accuracy 4 to 20 mA: 0.05% of reading @ 25°C
24VDC loop output power
1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power
Shipped with Each Unit
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector
Certifications CE and ATEX
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Compatible products in this product line also include:
Modbus TCP/IP to HART Analog Gateway
(5208-MNET-HART / 5228-MNET-HART)
DF1Master/Slave to HARTAnalog Gateway
(5108-DFCM-HART / 5128-DFCM-HART)
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5208-DFNT-HART / 5228-DFNT-HART
EtherNet/IP to HART Analog Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52 Specifications are subject to change without notice.
Copyright © ProSoft Technology, Inc. 2013. All Rights Reserved.
11/7/13
EtherNet/IP to Modbus Master/Slave Gateway 5201/5202-DFNT-MCM(4)
The DFNT-MCM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate Modbus serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to Modbus Master/Slave Gateway 5201/5202-DFNT-MCM(4) The ProLinx EtherNet/IP to Modbus Master/Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DFNT-MCM 5202-DFNT-MCM4
EtherNet/IP to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to PROFIBUS DP Master Gateway 5204-DFNT-PDPM
The DFNT-PDPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to PROFIBUS DP Master Gateway 5204-DFNT-PDPM The ProLinx EtherNet/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable. Status Data Error codes, counters and port status
available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5204-DFNT-PDPM EtherNet/IP to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to PROFIBUS DPV1 Master Gateway 5204-DFNT-PDPMV1
The DFNT-PDPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to PROFIBUS DPV1 Master Gateway 5204-DFNT-PDPMV1 The ProLinx EtherNet/IP to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client
Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
PROFIBUS DP Master V1 The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol. The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network. • Master Busview configuration interface via included ProSoft
Configuration Builder software (see PSW-PCB)• Project-unique GSD file import library• Monitoring and Modification of process data and DPV1 acyclic data• Multi-drop on a PROFIBUS DPV1 network drop with other compatible
devices• Ability to be used with a repeater as a PROFIBUS Master with
PROFIBUS PA slaves on the network• Automatic project documentation• Automatic Bus Parameter calculation• Online slave diagnostics• Supports all standardized baud rates, up to 12Mbps• Supports extended diagnostic data (DPV1)• Auto baud detection at all valid PROFIBUS DPV1 rates• Multiple modules can be placed in a single rack• CRC checksum determination of slave configuration consistency to
processor• Master Status LED Indicators for Operations, Network Drop
Communication, Master Token-Hold• FDT/DTM PROFIBUS master transport communication DTM software
included (see PSW-CDTM-PDPM)
PROFIBUS Master Specifications • Up to 125 Slaves can be connected with a repeater• Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words)
output data• Supports Extended Diagnostic Data• RS-485 optically isolated PROFIBUS Interface with on board DC-DC
converter• Acyclic communications (DPV1), Read and Write• Alarm Handling (DPV1)• Supports Sync and Freeze commands• Supports PROFIdrive 3.1 compliant parameter read and write
operations• Supports Multicast and Broadcast telegrams (DPV1)
PROFIBUS Master Port • DB-9F Optically Isolated RS-485• Ready, Run, Error and Token LED Indicators• PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female
connector and isolated Opto-Couplers
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification DescriptionPower Supply 24 VDC nominal
18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Specification DescriptionOperating Temperature -20 to 50°C (-4 to 122°F) Storage Temperature -40 to 85°C (-40 to 185°F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x
5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5204-DFNT-PDPMV1 EtherNet/IP to PROFIBUS DPV1
Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved.
February 29, 2008
EtherNet/IP to PROFIBUS DP Slave Gateway 5205-DFNT-PDPS
The DFNT-PDPS modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP master device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to PROFIBUS DP Slave Gateway 5205-DFNT-PDPS The ProLinx EtherNet/IP to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications Polling of command list User configurable polling of commands,
including disabled, continuous and on change of data (write only).
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5205-DFNT-PDPS EtherNet/IP to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
EtherNet/IP to Rockwell Automation Remote I/O Gateway 5210-DFNT-RIO
The DFNT-RIO modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a Remote I/O device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
EtherNet/IP to Rockwell Automation Remote I/O Gateway 5210-DFNT-RIO The ProLinx EtherNet/IP to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on an EtherNet/IP network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
EtherNet/IP Client Specifications Polling of command list User configurable polling of commands,
including disabled, continuous and on change of data (write only).
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port DB-9M RS-232 only
No hardware handshaking Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5210-DFNT-RIO EtherNet/IP to Rockwell Automation Remote I/O Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DF1 Serial Port Expander Gateway 5102-DFS3-DFM
The Serial Port Expander adds three additional slave ports for a DF1 based device. This allows users to connect programming software, HMI, and modems to processors simultaneously. Commands from the host devices are passed through the module and routed directly to the front port of the processor. This allows a processor’s port to be expanded to allow communication with a variety of devices at the same time. Typical applications include local ladder configuration, local operator interface, and wireless concentrator for remote programming and data collection.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DF1 Serial Port Expander Gateway 5102-DFS3-DFM The ProLinx DF1 Serial Port Expander Gateway allows you to attach up to three separate DF1 master devices to a single DF1 slave.
The module is designed to act as a multiplexer, allowing simultaneous connections from multiple DF1 masters to a single DF1 slave. A common use for the module is to have an HMI panel, SCADA package, and Programming software all communicating to the same DF1 channel 0 port of the Rockwell Automation processor.
The module provides a single DF1 Master port and three DF1 Slave ports.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC
Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
DF1 Master Driver
Polling of Command List
User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex – Slave (not peer mode) Half Duplex – Polled
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DFS3-DFM DF1 Serial Port Expander Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to IEC 60870-5-103 Master Gateway 5102-DH485-103M
The DH485-103M modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate an IEC 103 slave device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to IEC 60870-5-103 Master Gateway 5102-DH485-103M The ProLinx DH-485 to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a DH-485 network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one IEC 103 Master configurable serial port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters Communication parameters Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters Baud Rate
Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DH485-103M DH-485 to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to ASCII Generic Serial Gateway 5102-DH485-ASCII3
The DH485-ASCII modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate ASCII serial input device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to ASCII Generic Serial Gateway 5102-DH485-ASCII3 The ProLinx DH-485 to ASCII Generic Serial Gateway creates a powerful connection between devices on a DH-485 network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and three ASCII configurable serial ports.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DH485-ASCII3 DH-485 to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to Honeywell DE Master Gateway 5106/5126-DH485-DEM(2)
The DH485-DEM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate Honeywell DE devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE device support, the module provides a very powerful interface to the many Honeywell DE devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to Honeywell DE Master Gateway 5106/5126-DH485-DEM(2) The ProLinx DH-485 to Honeywell DE Master Gateway creates a powerful connection between devices on a DH-485 network and Honeywell DE devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and up to eight configurable Honeywell DE Master channels.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
DE Communications • Built in accordance with the Honeywell DE specification • Supports up to 8 single PV transmitters, 2 multivariable
transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal Assembly (FTA)
with ProSoft-supplied cable • Supports redundant and non-redundant FTA implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
LEDs for Visual Module Status
DE Active DE Error
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port DB-9M RS-232 only
No hardware handshaking Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5106-DH485-DEM 5126-DH485-DEM2
DH-485 to Honeywell DE Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to DF1 Master/Slave Gateway 5102-DH485-DFCM3
The DH485-DFCM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate DF1 devices into a system. The DH- 485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
DISCONTINUED DH-485 to DF1 Master/Slave Gateway 5102-DH485-DFCM3 The ProLinx DH-485 to DF1 Master/Slave Gateway creates a powerful connection between devices on a DH-485 network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and three DF1 Master or Slave configurable serial ports.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC
Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and
word/bit count Polling of command list User configurable polling of commands,
including disabled, continuous and on change of data (write only)
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Specification Description Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x
5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x
Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd
6.934cmW x 11.48cmD) LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
RTS Timing delays: 0 to 65535 ms Error Checking BCC and CRC
Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multi-drop support
Configuration Serial Port Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators
Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address,
register to/from addressing and word/bit count
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable
RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL 1577
3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or
4, depending on ports)
ProSoft Configuration Builder Polling of Command List
User-configurable polling of commands, including disabled, continuous, and on change
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your
of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled
application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a
Configurable parameters per slave
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words)
complete list of products.
port Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
DH-485 to DNP 3.0 Master Gateway 5102-DH485-DNPM
The DH485-DNPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a DNP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED DH-485 to DNP 3.0 Master Gateway
5102-DH485-DNPM The ProLinx DH-485 to DNP 3.0 Master gateways create a powerful connection between a DH-485 device and a DNP 3.0 slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and one DNP 3.0 master configurable serial port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
DH485 Functioning as a Master
Polling of command list User configurable polling of commands, including disabled, continuous and on
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
DNP 3.0 Master
change of data (write only) Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2 DNP Object Support DNPM Driver Manual contains full Object
Definition documentation
DNP Master
Node address 0 to 65534 – software selectable Slave count Up to 40 slave devices Command count Up to 300 user defined commands to
interface with remote slave devices
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
DH-485 to DNP 3.0 Slave Gateway 5102-DH485-DNPS
The DH485-DNPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a DNP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to DNP 3.0 Slave Gateway 5102-DH485-DNPS The ProLinx DH-485 to DNP 3.0 Slave Gateway creates a powerful connection between a DH-485 device and a DNP 3.0 master device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and one DNP 3.0 slave configurable serial port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
DH485 Functioning as a Master
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DH485-DNPS DH-485 to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to HART Multi-drop Gateway 5107/5127-DH485-HART(2)
The DH485-HART modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate HART Multi-drop devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED DH-485 to HART Multi-drop Gateway
5107/5127-DH485-HART(2) The ProLinx DH-485 to HART Multi-drop Gateway creates a powerful connection between devices on a DH-485 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and up to eight configurable HART Multi-drop channels.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and
word/bit count Polling of command list User configurable polling of commands,
including disabled, continuous and on change of data (write only)
HART The HART Master Protocol exists in 4 channel implementations with
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
HART2 allowing 8 channels. This driver can be configured on an Ethernet Port (Ethernet RJ45 Connector
individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters Communication parameters Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
modules only) Link and Activity LED indicators Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL
1577 3000V DC min. port to ground and port to
logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way
Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy
to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 16, 2013
extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most
widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
DH-485 to Modbus Master/Slave Gateway 5102-DH485-MCM3
The DH485-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a DH-485 device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to Modbus Master/Slave Gateway 5102-DH485-MCM3 The ProLinx DH-485 to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and a DH-485 master or slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and three Modbus Master or Slave configurable serial ports. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters
Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature 0 to 50°C (32 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5102-DH485-MCM3 DH-485 to Modbus Master/Slave Gateway
Note: The 5102-DH485-MCM3 is in a Final Sales Period of two years, effective October 14, 2008 until October 14, 2010. Thereafter, the product will continue to be supported until October 14, 2014. Recommended replacement product is the 5201-MNET-DH485 Modbus TCP/IPClient/Server to DH485 Master/Slave Communication Gateway. For more information on the Product Retirement Program, please visit: http://www.prosoft-technology.com/products/product_retirement_program To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to PROFIBUS DP Master Gateway 5104-DH485-PDPM
The DH485-PDPM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a PROFIBUS DP slave device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with
DISCONTINUED DH-485 to PROFIBUS DP Master Gateway
5104-DH485-PDPM The ProLinx DH-485 to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DH-485 network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and PROFIBUS DP Master port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC
unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft-
Communication Parameters
Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd
technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed
with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master
port, each fully configurable for
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED
Serial Activity and Error LED Status
function, slave address, register Configuration Serial DB-9M RS-232 only
to/from addressing and word/bit Port No hardware handshaking
count Ethernet Port (Ethernet RJ45 Connector
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data
(write only)
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
modules only) Link and Activity LED indicators Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
Communication Baud Rate: 9.6 kbit/s – 12 Mbit/s ProSoft Configuration Builder parameters PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable. Status Data Error codes, counters and port
status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x
11.48cmD)
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products. Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
DH-485 to PROFIBUS DP Slave Gateway 5105-DH485-PDPS
The DH485-PDPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a PROFIBUS DP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Discontinued DH-485 to PROFIBUS DP Slave Gateway
5105-DH485-PDPS The ProLinx DH-485 to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DH-485 network and a PROFIBUS DP master device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and PROFIBUS DP Slave port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED
Serial Activity and Error LED Status Configuration Serial Port DB-9M RS-232 only
No hardware handshaking
change of data (write only) Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s
Supported I/O length 244 bytes Input data 244 bytes Output data
400 bytes total
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to
logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode
application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125
Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier
Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in.
(13.2cmH x 6.934cmW x 11.48cmD)
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 16, 2013
DNP 3.0 Master to DF1 Master/Slave Gateway 5102-DNPM-DFCM3
The DNP-DFCM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate a DNP Slave device into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP Slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Master to DF1 Master/Slave Gateway 5102-DNPM-DFCM3 The ProLinx DNP 3.0 Master to DF1 Master/Slave Gateway creates a powerful connection between devices on a DF1 network and a DNP Slave device. This stand-alone DIN-rail mounted protocol gateway provides one DNP configurable serial port and three DF1 Master/Slave configurable serial ports.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2 DNP Object Support DNPM Driver Manual contains full Object
Definition documentation
DNP Master Node address 0 to 65534 – software selectable Slave count Up to 40 slave devices Command count Up to 300 user defined commands to
interface with remote slave devices
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC
General Parameters
Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex – Slave (not peer mode) Half Duplex – Polled
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DNPM-DFCM3 DNP 3.0 Master to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 Master to Modbus Master/Slave Gateway 5102-DNPM-MCM3
The DNPM-MCM modules are the ideal solution for the many applications where DNP Master connectivity can be used to integrate Modbus devices into a system. The DNP gateway is a powerful module designed with both Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Master to Modbus Master/Slave Gateway 5102-DNPM-MCM3 The ProLinx DNP 3.0 Master to Modbus Master/Slave Gateway creates a powerful connection between devices on a DNP network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides up to four serial ports.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2 DNP Object Support DNPM Driver Manual contains full Object
Definition documentation
DNP Master
Node address 0 to 65534 – software selectable Slave count Up to 40 slave devices Command count Up to 300 user defined commands to
interface with remote slave devices
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
General Parameters – Modbus Protocol
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave
Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DNPM-MCM3 DNP 3.0 Master to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 Master to PROFIBUS DP Master Gateway 5204-DNPM-PDPM
The DNPM-PDPM modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Master device into a system. The DNP 3.0 Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Master to PROFIBUS DP Master Gateway 5105-DNPM-PDPM The ProLinx DNP 3.0 Master to PROFIBUS DP Master creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2
DNP Object Support DNPM Driver Manual contains full Object Definition documentation
DNP Master
Node address 0 to 65534 – software selectable
Slave count Up to 40 slave devices
Command count Up to 300 user defined commands to interface with remote slave devices
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Specification Description
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5204-DNPM-PDPM DNP 3.0 Master to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
DNP 3.0 Master to PROFIBUS DP Slave Gateway
5105-DNPM-PDPS
The ProLinx DNP 3.0 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port. The DNP 3.0 Master protocol supports Master implementations of the protocol on one port. This port is fully configurable. The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished, using the provided ProSoft Configuration Builder software.
Features Benefits
Powerful network integration Allows movement of data between dissimilar networks using two communication protocols on one gateway
Protocols share access to a common memory database to exchange data between networks
View diagnostic data for both networks from a single configuration/debug port
DNP 3.0 Master protocol interface DNP 3.0 Master – Level 2 Connects to up to 40 slave devices Up to 300 commands
PROFIBUS DP-V0 Slave protocol interface
Adds PROFIBUS DP Slave device monitoring and control to a DNP 3.0 Master network Easy configuration - GSD file provided 122 words input/122 words output, 200 words maximum I/O
ProSoft Configuration Builder software included
Graphical drag-and-drop configuration tool for simple module configuration Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics View module database contents through serial connection to a desktop PC
Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind
Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft software tools tightly integrate with our hardware...a simple and quick, total
solution to help you make our products fit your applications
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
The PROFIBUS DP-V0 Slave driver provides a powerful and easy-to-use interface between a PROFIBUS DP network and other networks. This slave implementation gives access to up to 244 bytes of PROFIBUS Input data and up to 244 bytes of PROFIBUS Output data, with a maximum configurable limit of 400 total data bytes. These Input and Output data areas are fixed in the ProLinx gateway’s data memory, allowing the user to monitor or manipulate this data with either of the installed gateway protocols.
Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
DNP 3.0 Master Functional Specifications The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, and so on). General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master - Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition
documentation DNP Master Node address 0 to 65534 (software selectable) Slave count Up to 40 slave devices Command count Up to 300 user defined commands to interface with remote
slave devices
PROFIBUS DP Slave Functional Specifications GSD File PRLX05A5.GSD
Available on Product DVD, or downloadable from ProSoft Technology® web site
Communication parameters Baud Rate: 9.6 kbps to 12 Mbps Supported I/O length 244 bytes Input data
244 bytes Output data 400 total data bytes, maximum
Supported PROFIBUS DP-V0 features
PROFIBUS DP-V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 0 to 125 Data byte swapping Action on loss of PROFIBUS connection Communication Fail Timeout Multiplier Status Data location in Internal Database
Where Automation Connects™ Global Distribution ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, technical support and a three year warranty. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under About Us on the web site at:
www.prosoft-technology.com
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications Specification Description Power Supply 24 Vdc nominal
18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum Operating Temperature -4°F to 122°F (-20°C to 50°C) Storage Temperature -40°F to 185°F (-40°C to 85°C) Relative Humidity 5% to 95% RH with no condensation Shock IEC 60068-2-6; 5G @ 10-150HZ Vibration IEC 60068-2-27; 20G @ 11ms, 3-Axis (Operational) Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators (On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s)
2 DB-9F Female Modbus Plus Ports
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped WITH Each Unit
Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals and Certifications ATEX CE cULus CB Safety
Where Automation Connects™ Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology.com
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information To order this product, please use the following:
DNP 3.0 Master to PROFIBUS DP Slave Gateway 5105-DNPM-PDPS
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select How to Buy from the menu.
Copyright © 2013 ProSoft Technology, Inc., all rights reserved. 5/31/2013
Specifications subject to change without notice.
DNP 3.0 Slave to DF1 Master/Slave Gateway 5102-DNPS-DFCM3
The DNPS-DFCM modules are the ideal solution for the many applications where DNP connectivity can be used to integrate DF1 Master or Slave devices into a system. The DNP 3.0 Slave gateway is a powerful module designed with level 2 Slave support, enabling easy connection between DNP masters and devices on a dissimilar network. In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Slave to DF1 Master/Slave Gateway 5102-DNPS-DFCM3 The ProLinx DNP 3.0 Slave to DF1 Master/Slave Gateway creates a powerful connection between devices on a DNP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one DNP Slave serial port and three DF1 serial ports individually configurable as either Master or Slave.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
General Parameters Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DNPS-DFCM3 DNP 3.0 Slave to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 Slave to Modbus Master/Slave Gateway 5102-DNPS-MCM3
The DNPS-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a DNP 3.0 Master device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Slave to Modbus Master/Slave Gateway 5102-DNPS-MCM3 The ProLinx DNP 3.0 Slave to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and a DNP master device. This stand-alone DIN-rail mounted protocol gateway provides one DNP 3.0 Slave configurable serial port, and three Modbus Master or Slave configurable serial ports.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master
port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list
Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-DNPS-MCM3 DNP 3.0 Slave to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 Slave to PROFIBUS DP Master Gateway 5104-DNPS-PDPM
The DNPS-PDPM modules are the ideal solution for the many applications where DNP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The DNP 3.0 Slave gateway is a powerful module designed with Client support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Slave to PROFIBUS DP Master Gateway 5104-DNPS-PDPM The ProLinx DNP 3.0 Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on a PROFIBUS network and DNP devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one DB9F port configurable for PDPM.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for
configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 VDC to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max @ 24 VDC
Operating Temperature 32° F to 122° F (0° C to 50° C)
Storage Temperature –40° F to 185° F (–40° C to 85° C)
Relative Humidity 5% to 95% (with no condensation)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5104-DNPS-PDPM DNP 3.0 Slave to PROFIBUS DP Master Gateway
To place an order please contact your local ProSoftTechnology distributor. For a list of ProSoft distributorsnear you, go to: http://www.prosoft-technology.com
Distributors Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2010. All Rights Reserved.
April 12, 2010
DNP 3.0 Slave to PROFIBUS DP Slave Gateway 5105-DNPS-PDPS
The DNPS-PDPS modules are the ideal solution for the many applications where PROFIBUS connectivity can be used to integrate DNP serial devices into a system. The PROFIBUS gateway is a powerful module designed with Client support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 Slave to PROFIBUS DP Slave Gateway 5105-DNPS-PDPS The ProLinx DNP Slave to PROFIBUS DP Slave Gateway creates a powerful connection between DNP and PROFIBUS master devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS Slave port.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped
by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters
PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-DNPS-PDPS DNP 3.0 Slave to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 over Ethernet to IEC 60870-5-103 Master Gateway 5201-DNPSNET-103M
The DNPSNET-103M modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate an IEC 103 slave device into a system. The DNP over Ethernet gateway is a powerful module designed with level 2 Server support, enabling easy connection to other DNP devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 over Ethernet to IEC 60870-5-103 Master Gateway 5201-DNPSNET-103M The ProLinx DNP over Ethernet to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a DNP over Ethernet network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000
Protocols TCP (1 connection) and UDP
Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses)
• Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses)
• Configurable Time Sync and General Interrogation messages during initialization
• Supports General Interrogation, General Command and Time Synchronization Commands.
General Parameters Communication parameters
Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters
Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DNPSNET-103M DNP 3.0 over Ethernet to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 over Ethernet to DF1 Master/Slave Gateway 5201-DNPSNET-DFCM
The DNPSNET-DFCM modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate DF1 devices into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 over Ethernet to DF1 Master/Slave Gateway 5201-DNPSNET-DFCM The ProLinx DNP over Ethernet to DF1 Master/Slave Gateway creates a powerful connection between devices on a DNP over Ethernet network and DF1 Master/Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters Internal Database Binary Inputs: 8000 points (500 words)
Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2 DNP Server Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
General Parameters Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature 0 to 50°C (32 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DNPSNET-DFCM DNP 3.0 over Ethernet to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DH-485 to DNP 3.0 over Ethernet Gateway 5201-DH485-DNPSNET
The DH485-DNPSNET modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a DH-485 device into a system. The DNP over Ethernet gateway is a powerful module designed with level 2 Server support, enabling easy connection to other DNP 3.0 devices. In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED DH-485 to DNP 3.0 over Ethernet Gateway 5201-DH485-DNPSNET The ProLinx DH-485 to DNP over Ethernet Gateway creates a powerful connection between devices on a DNP over Ethernet network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
DH485 Functioning as a Master Specification Description
Polling of command list User configurable polling of commands, Ethernet Port (Ethernet RJ45 Connector
including disabled, continuous and on change of data (write only)
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters Internal Database Binary Inputs: 8000 points (500 words)
Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
modules only) Link and Activity LED indicators Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL
1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 16, 2013
DNP 3.0 over Ethernet to Modbus Master/Slave Gateway 5201/5202-DNPSNET-MCM(4)
The DNPSNET-MCM modules are the ideal solution for the many applications where DNP Ethernet connectivity can be used to integrate MCM serial devices into a system. The DNP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 over Ethernet to Modbus Master/Slave Gateway 5201/5202-DNPSNET-MCM(4) The ProLinx DNPSNET to Modbus Master/Slave Gateway creates a powerful connection between devices on a DNP Ethernet network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DNPSNET-MCM 5202-DNPSNET-MCM4
DNP 3.0 over Ethernet to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 over Ethernet to PROFIBUS DP Master Gateway 5204-DNPSNET-PDPM
The DNPSNET-PDPM modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP slave device into a system. The DNP over Ethernet gateway is a powerful module designed with Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Master support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED DNP 3.0 over Ethernet to PROFIBUS DP Master Gateway
5204-DNPSNET-PDPM The ProLinx DNP over Ethernet to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DNP over Ethernet network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Master configurable DB9F port.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2 DNP Server
Service Port 20000
Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables Communication parameters
PROFIBUS Master
Baud Rate: 9.6 kbit/s – 12 Mbit/s 4 ft RS-232 configuration cable 2.5mm screwdriver
CD (docs and Configuration utility) Command List Read Diag
Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway 5205-DNPSNET-PDPS
The DNPSNET-PDPS modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP master device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway 5205-DNPSNET-PDPS The ProLinx DNP over Ethernet to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP over Ethernet network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000 Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory
allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5205-DNPSNET-PDPS DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DNP 3.0 over Ethernet to Rockwell Automation Remote I/O Gateway 5210-DNPSNET-RIO
The DNPSNET-RIO modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate as a Remote I/O Adapter in a system. The DNP over Ethernet gateway is a powerful module designed with Server support, enabling easy connection to other DNP devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED DNP 3.0 over Ethernet to Rockwell Automation Remote I/O Gateway
5210-DNPSNET-RIO The ProLinx DNP over Ethernet to Remote I/O Gateway creates a powerful connection between devices on a DNP over Ethernet network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters
Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2 DNP Server
Service Port 20000
Protocols TCP (1 connection) and UDP Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
Specification Description
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination
included Serial Port Isolation 2500V RMS port signal isolation per
UL 1577 3000V DC min. port to ground and
port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver
Rack Number Addressing
0 to 63 CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional Specifications Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack
size configuration BTW Command – up to 64 words BTR Command – up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination
connector
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types.
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways,
providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x
11.48cmD) LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
Configuration Serial DB-9M RS-232 only Port No hardware handshaking
Modbus Plus to IEC 60870-5-101 Slave Gateway 5301-MBP-101S
The MBP-101S modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an IEC 101 master device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 101 Slave support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
DISCONTINUED Modbus Plus to IEC 60870-5-101 Slave Gateway
5301-MBP-101S The ProLinx Modbus Plus to IEC 60870-5-101 Slave Gateway creates a powerful connection between devices on a Modbus Plus network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one IEC 101 Slave configurable serial port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
+603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America
Address Scope 1 to 64 Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
+1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected]
Polling of command list
Configurable polling of command list, including continuous and on change of data
Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
General specifications include: Configuration Serial DB-9M RS-232 only
• User-definable module memory usage Port No hardware handshaking
• Storage of IEC time used in module is available in Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
the database • Protocol implementation conforms to the IEC 60870-
5-101 specification with fully configurable parameters
• Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination
included Serial Port Isolation 2500V RMS port signal isolation per
UL 1577 3000V DC min. port to ground and
port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable 2.5mm screwdriver
Communication parameters
IEC 60870-5-101 Slave Configurable Parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal
Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x
11.48cmD)
industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
Modbus Plus to IEC 60870-5-103 Master Gateway 5301-MBP-103M
The MBP-103M modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an IEC 103 slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 103 Master support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
DISCONTINUED Modbus Plus to IEC 60870-5-103 Master Gateway
5301-MBP-103M The ProLinx Modbus Plus to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a Modbus Plus network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one IEC 103 Master configurable serial port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.)
Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com
Global data write (32 words max.) Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Languages spoken include: French, English
North America +1.661.716.5100, [email protected]
Polling of command list
Configurable polling of command list, including continuous and on change of data
Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports: Specification Description
• 16 slaves (sessions with distinct Data Link Addresses)
• Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses)
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
• Configurable Time Sync and General Interrogation messages during initialization
• Supports General Interrogation, General Command and Time Synchronization Commands.
General Parameters
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577
Communication parameters
IEC 60870-5-103 Master
Configurable Parameters
Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
Modbus Plus to IEC 60870-5-104 Server Gateway 5303-MBP-104S
The MBP-104S modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate a Modbus Plus device into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 devices. In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to IEC 60870-5-104 Server Gateway 5303-MBP-104S The ProLinx Modbus Plus to IEC60870-5-104 Server Gateway creates a powerful connection between devices on an IEC 104 Server network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2)
16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64 Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include: • User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5303-MBP-104S Modbus Plus to IEC 60870-5-104 Server Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
.
Modbus Plus to ASCII Generic Serial Gateway 5301/5302-MBP-ASCII(4)
The MBP-ASCII modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an ASCII generic serial input device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to ASCII Generic Serial Gateway 5301/5302-MBP-ASCII(4) The ProLinx Modbus Plus to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus Plus network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and up to four ASCII configurable serial ports.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list
Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII
communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5301/5302-MBP-ASCII(4) Modbus Plus to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to DF1 Master/Slave Gateway 5301/5302-MBP-DFCM(4)
The MBP-DFCM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DF1 devices into a system. The Modbus Plus gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to DF1 Master/Slave Gateway 5301/5302-MBP-DFCM(4) The ProLinx Modbus Plus to DF1 Master/Slave Gateway creates a powerful connection between devices on a Modbus Plus network and DF1 Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB-9F port and up to four configurable serial ports.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2)
16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port,
fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave Node address 1 to 64 – software selectable
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC
General Parameters Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5301-MBP-DFCM 5302-MBP-DFCM4
Modbus Plus to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to EtherNet/IP Gateway 5303-MBP-DFNT
The MBP-DFNT modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a Modbus Plus device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to EtherNet/IP Gateway 5303-MBP-DFNT The ProLinx Modbus Plus to EtherNet/IP Gateway creates a powerful connection between devices on an EtherNet/IP network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5303-MBP-DFNT Modbus Plus to EtherNet/IP Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to DH-485 Gateway 5301-MBP-DH485
The MBP-DH485 modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DH-485 devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to DH-485 Gateway 5301-MBP-DH485 The ProLinx Modbus Plus to DH-485 Gateway creates a powerful connection between devices on a Modbus Plus network and DH-485 devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus DB9F port and one DH-485 configurable serial port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list
Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC Communication Parameters
Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port,
each fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list
User configurable polling of commands, including disabled, continuous and on change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports
RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5301-MBP-DH485 Modbus Plus to DH-485 Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to DNP 3.0 Slave Gateway 5301-MBP-DNPS
The MBP-DNPS modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DNP serial devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus Plus devices with peer to peer support. In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to DNP 3.0 Slave Gateway 5301-MBP-DNPS The ProLinx Modbus Plus to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Modbus Plus network and DNP master devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable DB9F port and one serial port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5301-MBP-DNPS Modbus Plus to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to DNP 3.0 over Ethernet Gateway 5303-MBP-DNPSNET
The MBP-DNPSNET modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a Modbus Plus device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to DNP 3.0 over Ethernet Gateway 5303-MBP-DNPSNET The ProLinx Modbus Plus to DNP over Ethernet Gateway creates a powerful connection between devices on a DNP over Ethernet network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN.
General Parameters Internal Database Binary Inputs: 8000 points (500
words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points
DNP Mode DNP 3.0 Slave – Level 2
DNP Server
Service Port 20000
Protocols TCP (1 connection) and UDP
Node address 0 to 65534 (software selectable)
The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5303-MBP-DNPSNET Modbus Plus to DNP 3.0 over Ethernet Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to HART Multi-drop Gateway 5307-MBP-HART
The MBP-HART modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate HART Multi-drop devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART Multi-drop support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to HART Multi-drop Gateway 5307-MBP-HART The ProLinx Modbus Plus to HART Multi-drop Gateway creates a powerful connection between devices on a Modbus Plus network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and four HART Multi-drop channels.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list
Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters Communication parameters
Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver Command List Up to 100 fully configurable
commands per channel Polling of command list
User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5307-MBP-HART Modbus Plus to HART Multi-drop Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to Modbus Master/Slave Gateway 5301/5302-MBP-MCM(4)
The MBP-MCM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate Modbus devices into a system. The Modbus Plus gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to Modbus Master/Slave Gateway 5301/5302-MBP-MCM(4) The ProLinx Modbus Plus to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus Plus network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus port and up to four Modbus enabled serial ports.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2)
16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port,
fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave Node address 1 to 64 – software selectable
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
General Parameters – Modbus Protocol
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave
Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5301-MBP-MCM 5302-MBP-MCM4
Modbus Plus to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to Modbus TCP/IP Gateway 5303-MBP-MNET
The MBP-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Modbus Plus device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to Modbus TCP/IP Gateway 5303-MBP-MNET The ProLinx Modbus Plus to Modbus TCP/IP Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
Modbus Plus The Modbus Plus protocol driver operates as a single peer-to-peer Modbus Plus Port with dual media-redundantconnectors which are not configurable as separate ports.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list
Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports Modbus Plus Connector Two DB9 female standard Modbus Plus connectors
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000 VDC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver DVD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5303-MBP-MNET Modbus Plus to Modbus TCP/IP
Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe
[email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2014. All Rights Reserved. May 9, 2014
Modbus Plus to PROFIBUS DP Master Gateway 5304-MBP-PDPM
The MBP-PDPM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to PROFIBUS DP Master Gateway 5304-MBP-PDPM The ProLinx Modbus Plus to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one PROFIBUS DP Master configurable DB9F port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list
Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5304-MBP-PDPM Modbus Plus to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus Plus to PROFIBUS DPV1 Master Gateway
5304-MBP-PDPMV1
The ProLinx Modbus Plus to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one PROFIBUS DPV1 Master configurable DB9F port.
The Modbus Plus protocol supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The PROFIBUS DPV1 Master protocol supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
Features Benefits
Powerful network integration ♦ Move data between dissimilar networks using two communication protocols on one gateway
♦ Protocols share access to a common memory database to exchange data between networks
♦ View diagnostic data for both networks from a single configuration/debug port
Modbus Plus protocol interface ♦ Modbus Plus serial port with dual media-redundant connectors
PROFIBUS DPV1 Master protocol interface
♦ CIPConnect® enabled. Module supports communications with ProSoft Configuration Builder
and FDT comDTM via Ethernet routing using Rockwell Automation Ethernet interface.
Backed by ProSoft Technology ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics.
PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
General Specifications - ProLinx ProLinx
® Communication gateways provide connectivity for two or more dissimilar
network types. The gateway, enclosed in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
General Specifications - MBP Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 milliseconds
Modbus Modes RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Data
Floating point data movement supported, including configurable support for Enron implementation
Modbus Function Codes
1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register15: Force( Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
General Specifications - PDPMV1 The PROFIBUS DPV1 Master implementation is a powerful communication interface for ® ® processors. Developed under license from , the module incorporates proprietary
backplane technology that enables powerful data exchange with processors.
The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The module acts as an input/output module between the PROFIBUS network and the processor. Data transfer from the processor is asynchronous with the I/O data transfer on the PROFIBUS network.
Schematic
Functional Specifications - Modbus Plus The Modbus Plus protocol (MBP) operates as a single, peer-to-peer, Modbus Plus Port with dual media-redundant connectors, which are not configurable as separate ports.
General Parameters
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words per node max.) Global data write (32 words per node max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous read or write commands and write on change of data (Function Code 16 Write command only)"
Modbus Plus Functioning as a Slave
Node address 1 to 64 (software selectable)
Functional Specifications - PROFIBUS DP Master V1 • Easy-to-use drag and drop Master Busview configuration interface via ProSoft
Configuration Builder software
• Project-unique GSD file import library
• Monitoring and Modification of process data and DPV1 acyclic data
• Multi-drop on a PROFIBUS DPV1 network with other compatible devices
• Automatic project documentation
• Automatic Bus Parameter calculation
• Online slave diagnostics
• Supports all standardized baud rates, up to 12Mbps
• Supports extended diagnostic data (DPV1)
• Auto baud detection at all valid PROFIBUS DPV1 rates
• CRC checksum determination of slave configuration consistency to processor
• Master Status LED Indicators for Operations, Network Communication, Master Token-Hold and Network Configuration.
• FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM)
• Up to 125 Slaves can be connected with a repeater
• Up to 1536 cyclic bytes input and 1536 bytes output data
• Supports Extended Diagnostic Data
• RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter
• Acyclic communications (DPV1), Read and Write
• Alarm Handling (DPV1)
• Supports Sync and Freeze commands
• Supports PROFIdrive 3.1 compliant parameter read and write operations • Supports Multicast and Broadcast telegrams (DPV1)
Where Automation Connects™
Global Distribution
We think like you do
ProSoft Technology® products are
distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support
We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices
We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology. com.
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications Specification Description
Power Supply 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum
Operating Temperature -4°F to 122°F (-20°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Relative Humidity 5 to 95% (without condensation)
Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators
(On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port
(Ethernet protocol gateways only)
10Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s)
(Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals & Certifications cULus ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cULus C22.2 No. 213-M1987
183151
Additional Products
ProSoft Technology® offers a full
complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information
To order this product, please use the following:
Modbus Plus to PROFIBUS DPV1 Master Gateway
5304-MBP-PDPMV1
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] fax to +33 (0) 5.61.78.40.52
Copyright © 2010 ProSoft Technology, Inc., all rights
reserved. 10/19/2010
Specifications subject to change without notice.
Modbus Plus to PROFIBUS DP Slave Gateway 5305-MBP-PDPS
The MBP-PDPS modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DP master device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS DP master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus to PROFIBUS DP Slave Gateway 5305-MBP-PDPS The ProLinx Modbus Plus to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and PROFIBUS DP Slave configurable DB9F port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters
Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Address Scope 1 to 64
Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Polling of command list Configurable polling of command list, including continuous and on change of data
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5305-MBP-PDPS Modbus Plus to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Plus to Rockwell Automation Remote I/O Gateway 5310-MBP-RIO
The MBP-RIO modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a Remote I/O device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
DISCONTINUED Modbus Plus to Rockwell Automation Remote I/O Gateway
5306-MBP-RIO The ProLinx Modbus Plus to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on a Modbus Plus network and a Remote I/O device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and Remote I/O port.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected]
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected]
Address Scope 1 to 64 Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected]
Polling of command list
Configurable polling of command list, including continuous and on change of data
Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
Rockwell Automation Remote I/O Specification Description The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit)
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activityity LED indicators
with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and
Rack Number 0 to 63 port to logic power isolation Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional Specifications Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack
size configuration BTW Command – up to 64 words
BTR Command – up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination
connector
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products. Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
Modbus Serial Port Expander 5102-MBS3-MBM
The Serial Port Expander adds three additional slave ports for a Modbus based device. This allows users to connect SCADA software, HMI, and modems to processors simultaneously. Commands from the host devices are passed through the module and routed directly to the front port of the processor. This allows a processor’s port to be expanded to allow communication with a variety of devices at the same time. Typical applications include SCADA software, local operator interface, and wireless concentrator for remote data collection.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Serial Port Expander Gateway 5102-MBS3-MBM The ProLinx Modbus Serial Port Expander module allows you to attach up to three separate Modbus master devices to a single Modbus slave.
The module is designed to act as a multiplexer, allowing simultaneous connections from multiple Modbus masters to a single Modbus slave. A common use for the module is to have an HMI panel and a SCADA package all communicating to the same Modbus slave port of a Modicon processor.
This stand-alone DIN-rail mounted protocol gateway provides a single Modbus Master port and three Modbus Slave ports.
All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
Modbus The serial port(s) on the gateway can be individually configured to support the Modbus protocol (RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Slave
Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MBS3-MBM Modbus Serial Port Expander
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 16, 2007
Modbus Master/Slave to IEC 60870-5-101 Slave Gateway 5102-MCM3-101S
The MCM-101S modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC 101 master device into a system. The IEC60870-5-101 Slave gateway is a powerful module designed with Slave support, enabling easy connection to an IEC 101 master device. In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to IEC 60870-5-101 Slave Gateway 5102-MCM3-101S The ProLinx Modbus Master/Slave to IEC60870-5-101 Slave Gateway creates a powerful connection between devices on a Modbus network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one IEC 101 Slave configurable serial port and three Modbus Master or Slave configurable serial ports.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in the database • Protocol implementation conforms to the IEC 60870-5-101
specification with fully configurable parameters • Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters
Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave
Configurable Parameters Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MCM3-101S Modbus Master/Slave to IEC 60870-5-101 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
IEC 60870-5-103 Master to Modbus Master/Slave Gateway 5102-MCM-103M
The MCM-103M modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC60870-5-103 slave device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Modbus devices (Modicon processors and many others). In combination with the IEC 103 device support, the module provides a very powerful interface to the many IEC 103 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to IEC 60870-5-103 Master Gateway 5102-MCM-103M The ProLinx Modbus Master/Slave to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a Modbus network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Master or Slave configurable serial port and one IEC 103 Master configurable serial port.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses) • Each slave (session) supports up to 3 sectors (with distinct
Common ASDU Addresses) • Configurable Time Sync and General Interrogation messages
during initialization • Supports General Interrogation, General Command and Time
Synchronization Commands.
General Parameters Communication parameters Baud Rate: 110 to 19200 baud
Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters Baud Rate
Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MCM-103M IEC 60870-5-103 Master to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Master/Slave to 'C' Programmable Application Development Module 5102-MCM4-ADM4
The 5102 MCM4-ADM4 module is the ideal solution for many applications where serial connectivity needs to be added to a Modbus Master/Slave platform. Example applications involving the 5102 MCM4-ADM4 module include:
• Bar code scanner interface • Legacy ASCII protocol connections • Terminal port emulation • Printer driver (alarm/status printer) • Customized protocol implementations
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to 'C' Programmable Application Development Module 5102-MCM4-ADM4 The ProLinx 'C' Programmable Application Development Module provides a powerful platform for bridging communications between your custom serial protocols. This stand-alone DIN-rail mounted protocol gateway provides four fully programmable serial ports.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
General Parameters – Modbus Protocol Polling of command list Configurable polling of command list,
including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
ADM The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module's hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API.
Applications for the ADM module may be developed using industry-standard DOS programming tools and the appropriate API components.
The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers.
Development Environment
• Operating system: General software DOS 6-XL • Compatible compiler (16-bit DOS target)
o Digital Mars C++ V8.49 (included) o Borland C++ V5.02
Application Programming Interfaces (API)
• Serial Port API: serial port functions • Backplane API: low level backplane functions • ADM API debug port functions: debug port functions, database
functions timer functions, high level backplane transfer functions, LED functions, flash read functions
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Specification Description
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MCM4-ADM4 Modbus Master/Slave to 'C' Programmable Application Development Module
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Master/Slave to ASCII Generic Serial Gateway 5102-MCM-ASCII3
The MCM-ASCII modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate ASCII serial devices into a system. The Modbus gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to ASCII Generic Serial Gateway 5102-MCM-ASCII3 The ProLinx Modbus Master/Slave to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus configurable serial port and three ASCII configurable serial ports.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
General Parameters – Modbus Protocol
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave
Node address 1 to 247 – software selectable
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MCM-ASCII3 Modbus Master/Slave to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Master/Slave to Honeywell DE Master Gateway 5106/5126-MCM-DEM(2)
The MCM-DEM modules are the ideal solution for the many applications where DEM connectivity can be used to integrate Modbus serial devices into a system. The Honeywell DE gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module
DISCONTINUED Modbus Master/Slave to Honeywell DE Master Gateway
5106/5126-MCM-DEM(2) The ProLinx Modbus Master/Slave to Honeywell DE Master Gateway creates a powerful connection between devices on a Honeywell DE network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable serial port and one 8 channel DEM block.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron
implementation Function Codes 1: Read Output Status
2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits
16: Write Multiple Data Register Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit
count. Polling of command list Configurable polling of command list,
including continuous and on change of data, and dynamically user or automatic enabled. Modbus Slave Node address 1 to 247 – software selectable
Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
DE Communications • Built in accordance with the Honeywell DE specification • Supports up to 8 single PV transmitters, 2 multivariable
transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal Assembly (FTA)
with ProSoft-supplied cable • Supports redundant and non-redundant FTA implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new
LEDs for Visual Module Status
DE Active DE Error
configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Modbus Master/Slave to DF1 Master/Slave Gateway 5102-MCM4-DFCM4
This module is fully configurable, allowing any of its four serial ports to be configured as either a Master or Slave utilizing either the DF1 or Modbus Protocols. This provides a great deal of application flexibility as the module can be used as a data concentrator (when configuring all four ports for the same protocol) or the module database can be shared between the DF1 and Modbus networks to allow the module to work as a bridge between the two different protocols. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to DF1 Master/Slave Gateway 5102-MCM4-DFCM4 The ProLinx Modbus Master/Slave to DF1 Master/Slave Gateway creates a powerful connection between Modbus Master/Slave and DF1 Master/Slave networks and devices. This stand-alone DIN-rail mounted protocol gateway provides four serial ports, each individually configurable as a Modbus or DF1 Master or Slave.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing
radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Specification Description Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH
x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5102-MCM4-DFCM4 Modbus Master/Slave to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Master/Slave to HART Multi-drop Gateway 5107/5127-MCM-HART(2)
The MCM-HART modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate HART serial devices into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART device support, the module provides a very powerful interface to the over two-million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to HART Multi-drop Gateway 5107/5127-MCM-HART(2) The ProLinx Modbus Master/Slave to HART Multi-Drop Gateway creates a powerful connection between devices on a Modbus network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight configurable HART channels.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5107-MCM-HART 5127-MCM-HART2
Modbus Master/Slave to HART Multi-drop Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus Master/Slave to PROFIBUS DP Master Gateway 5104-MCM-PDPM
The MCM-PDPM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus Master/Slave gateway is a powerful module designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to PROFIBUS DP Master Gateway 5104-MCM-PDPM The ProLinx Modbus Master/Slave to PROFIBUS Master Gateway creates a powerful connection between devices on a Modbus network and a PROFIBUS DP Slave device. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS Master DB9F port.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable. Status Data Error codes, counters and port status
available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5104-MCM-PDPM Modbus Master/Slave to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus Serial to PROFIBUS DPV1 Master Gateway
5104-MCM-PDPMV1
The ProLinx Modbus Master/Slave to PROFIBUS DPV1 Master gateway creates a powerful connection between devices on a Modbus serial network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS Master DB9F port. The Modbus protocol supports both Master and Slave implementations. All Modbus serial ports are individually configurable, providing a choice of Modbus RTU or Modbus ASCII serial protocol support. The PROFIBUS DPV1 Master protocol supports complete Master specifications according to IEC 61158 Version 1 on either a single or multiple Master network. The gateway offers both cyclic and acyclic data transfers from PROFIBUS DPV1 slaves, as well as cyclic data transfers from DPV0 slaves.
Features Benefits
Powerful network integration Allows movement of data between dissimilar networks using two communication protocols on one gateway
Protocols share access to a common memory database to exchange data between networks
View diagnostic data for both networks from a single configuration/debug port
Modbus slave protocol interface Emulate Modbus slave device on each individually-configurable application port
Supports Modbus RTU and Modbus ASCII protocol versions
Floating point data movement supported, including support for Enron, Daniel®, and other implementations
Suitable for SCADA and field device interface applications
PROFIBUS DPV1 Master protocol interface
Supports cyclic communications in V0 and both cyclic and acyclic communications in V1
Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind
Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
Three-Year Warranty ensures reliability and protects against equipment failures
Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
Modbus Serial Port Specifications - PLX Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 milliseconds
Modbus Modes RTU mode (binary) with CRC-16, ASCII mode with LRC error checking
Modbus Function Codes
1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register15: Force( Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
General Specifications - PDPMV1 Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services, allowing communication with slave devices supporting PROFIBUS DPV0 or V1 protocols. The gateway acts as a link between the PROFIBUS network and the other gateway protocol. Data transfer by the other protocol is asynchronous from data transfer on the PROFIBUS network.
Functional Specifications Modbus Master
A port configured as a virtual Modbus Master actively issues Modbus commands to other nodes on the Modbus network. The Master ports have an optimized polling characteristic that polls slaves with communication problems less frequently. Command List Up to 100 command per Master port, each fully configurable for
function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained per active Modbus Master port.
Modbus Slave
A port configured as a Modbus slave permits a remote Master to interact with all data contained in the module. This data can be derived from other Modbus slave devices on the network, through a Master port, or from the gateway. Node address 1 to 247 (software selectable) Status Data Error codes, counters and port status available per configured
slave port
Functional Specifications - PROFIBUS DP Master V1 Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services, allowing communication with slave devices supporting PROFIBUS DPV0 or V1 protocols. The gateway acts as an input/output link between the PROFIBUS network and the other gateway protocol. Data transfer by the other protocol is asynchronous from data transfer on the PROFIBUS network. Easy-to-use drag and drop Master Busview configuration interface via ProSoft
Configuration Builder software Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network with other compatible devices Automatic project documentation, and Bus Parameter calculation Supports online slave diagnostics, and extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates up to 12Mbps CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Communication, Master Token-
Hold and Network Configuration. Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes input and 1536 bytes output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations
Where Automation Connects™
Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology. com.
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications Specification Description
Power Supply 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum
Operating Temperature -4°F to 122°F (-20°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Relative Humidity 5 to 95% (with no condensation)
Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators (On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s) (Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals & Certifications cULus ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cULus C22.2 No. 213-M1987
183151
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information
To order this product, please use the following:
Modbus Serial to PROFIBUS DPV1 Master Gateway
5104-MCM-PDPMV1
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to:
www.prosoft technology.com
and select Where to Buy from the menu.
Copyright © 2016 ProSoft Technology, Inc.
All rights reserved. 8/24/2016
Specifications subject to change without notice.
Modbus Master/Slave to PROFIBUS DP Slave Gateway 5105-MCM-PDPS
The PROFIBUS DP slave interface enables Siemens PLCs or a similar host supporting the PROFIBUS DP protocol to exchange data with other protocols. As such, possible applications of the PDPS product exist in nearly every sector of industry.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Master/Slave to PROFIBUS DP Slave Gateway 5105-MCM-PDPS The ProLinx Modbus Master/Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable serial port and one DB9F PDPS port.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5105-MCM-PDPS Modbus Master/Slave to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to IEC 60870-5-101 Slave Gateway 5201-MNET-101S
The MNET-101S modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 101 master device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 101 Slave support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to IEC 60870-5-101 Slave Gateway 5201-MNET-101S The ProLinx Modbus TCP/IP to IEC60870-5-101 Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 101 Slave configurable serial port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in the database
• Protocol implementation conforms to the IEC 60870-5-101 specification with fully configurable parameters
• Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters
Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave
Configurable Parameters Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-101S Modbus TCP/IP to IEC 60870-5-101 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to IEC 60870-5-103 Master Gateway 5201-MNET-103M
The MNET-103M modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 103 slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 103 Master support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to IEC 60870-5-103 Master Gateway 5201-MNET-103M The ProLinx Modbus TCP/IP to IEC60870-5-103 Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses)
• Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses)
• Configurable Time Sync and General Interrogation messages during initialization
• Supports General Interrogation, General Command and Time Synchronization Commands.
General Parameters Communication parameters
Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters
Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-103M Modbus TCP/IP to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to IEC 60870-5-104 Server Gateway 5201-MNET-104S
The MNET-104S modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 104 master device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC60870-5-104 Server device support, the module provides a very powerful interface to the many IEC 104 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to IEC 60870-5-104 Server Gateway 5201-MNET-104S The ProLinx Modbus TCP/IP to IEC60870-5-104 Server Gateway creates a powerful connection between devices on a Modbus TCP/IP network and IEC 104 client devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from an IEC-60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include: • User-definable module memory usage • Protocol implementation conforms to the IEC 60870-
5-104 specification with fully configurable parameters
• SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server Configurable Parameters
Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature
–40 to 85°C (–40 to 185°F)
Relative Humidity
5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports
RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation
2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-104S Modbus TCP/IP to IEC 60870-5-104 Server Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus TCP/IP to 'C' Programmable Serial 4 Port Gateway
5202-MNET-ADM4
The ProLinx® 'C' Programmable Application Development Module to Modbus TCP/IP creates a powerful platform for developing and running 'C' applications to communicate with Modbus TCP/IP networks and devices. The gateway provides one Ethernet port and four serial ports.
The Modbus TCP/IP protocol driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections. The driver recognizes both Modbus TCP/IP MBAP and Encapsulated Modbus messages.
The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers.
Features Benefits Powerful network integration ♦ Communicate between dissimilar networks
♦ Shared database exchanges information from devices on both networks
♦ View diagnostics between both networks
Modbus TCP/IP protocol interface ♦ Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols
♦ Suitable for SCADA and "foreign device" interface applications
♦ Floating point data movement supported, including configurable support for Enron and Daniel® floating point applications
♦ Communicate with programmable controllers, intelligent devices, sensors and instruments
♦ Allows PCs and HMIs to monitor field devices
'C' Programmable ♦ Develop and deploy 'C' applications for a custom implementation, or to protect a proprietary algorithm
♦ Interface Modbus TCP/IP devices to serial devices such as bar code scanners, alarm/status printers, terminal port emulation, and legacy serial protocols
♦ Up to four fully programmable serial ports available
♦ Rapidly create specialized applications using a familiar programming language
♦ Libraries include functions for backplane, ports, configuration, and data communication
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration The 'C' Programmable modules are completely configurable. The included API offers the option of text or binary configuration files, configuration through ladder logic, or hard-coded configuration within the application.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
Modbus TCP/IP ProSoft’s Modbus TCP/IP implementation uses the gateway’s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks.
Configurable floating point data movement is supported, including support for Enron or Daniel® floating point applications.
Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages..
• Supports five independent server connections for Service Port 502 (MBP) • Supports five independent server connections for Service Port 2000 (Encapsulated) • Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up
to 64,000 bits in any combination of data types throughout the memory database • Modbus data types overlap in the gateway’s memory database, so the same data
can be conveniently read or written as bit-level or register-level data.
Modbus TCP/IP Client (Master) • Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP
or Encapsulated Modbus message formats • Offers one client connection with up to 100 commands to talk to multiple severs
Status Data Error codes, counters, and port status available
'C' Programmable The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module’s hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API.
Applications for the ADM module may be developed using industry-standard DOS programming tools and the appropriate API components.
Development Environment • Operating system: General software DOS 6-XL • Compatible compiler (16-bit DOS target)
o Digital Mars C++ V8.49 (included) o Borland C++ V5.02
SDK Includes • ADM API LIB (library) File • ADM API Header File
• Complete API Documentation • Image file creation utility
• Image file download utility • DigitalMars 'C' compiler
• General software DOS 6-XL • Example Code Files
Functional Specifications Modbus TCP/IP Modbus Commands Supported (Client and Server)
1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
Configurable Parameters: (Client and Server)
Gateway IP Address, Modbus data type starting address offsets, Floating point start address and database offset
Schematic
Modbus TCP/IP (continued)
Configurable Parameters: Client Only
Minimum Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully-configurable Client commands Status Data Error codes reported individually for each command Command List Polling
Each command can be individually enabled or disabled; write-only-on-data-change is available
'C' Programmable Each API provides a library of function calls. This library supports any programming language that is compatible with the 'C' calling convention.
Initialization Open and close the API
Debug Port Debug port user interface
Database Read and write data to database
Timer Start and check timers
LED Set user LED indicators
Flash Parse configuration files
Hardware Specifications Specification Description Power Supply 24 VDC nominal, 18 to 32 VDC allowed
Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F) Relative Humidity 5% to 95% (non-condensing) Dimensions 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD)LED Indicators Power and Module Status, Application Status, Serial Port
Activity LED, Serial Activity and Error LED Status Configuration Serial Port
DB-9M RS-232 only, No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports
RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. isolation port to ground and port to logic
Shipped with Each Unit
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Agency Approval & Certification UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D cUL C22.2 No. 213-M1987
243333 183151
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information If you are unsure which product to select, please contact your local distributor. To order this product, please use the following:
Modbus TCP/IP to 'C' Programmable Gateway 5202-MNET-ADM4
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe / Middle East / Africa [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2009. All Rights
Reserved. June 02, 2009
Specifications subject to change without notice.
Modbus TCP/IP to ASCII Generic Serial Gateway 5201/5202-MNET-ASCII(4)
The MNET-ASCII modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate ASCII generic serial input devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to ASCII Generic Serial Gateway 5201/5202-MNET-ASCII(4) The ProLinx Modbus TCP/IP to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus TCP/IP network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four ASCII configurable serial ports.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Transmit and Receive buffer size
255 bytes each
Transmit character with pacing
0 to 65535 millisecond delay between each transmitted character.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-ASCII 5202-MNET-ASCII4
Modbus TCP/IP to ASCII Generic Serial Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus TCP/IP to BACnet/IP Client Gateway
5201-MNET-BACNET The ProLinx Modbus TCP/IP to BACnet/IP Client Gateway creates a powerful connection between devices on a Modbus TCP/IP network and BACNET devices. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port. The Modbus TCP/IP driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP. The driver allows Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. The BACnet protocol provides mechanisms by which computerized equipment of arbitrary function may exchange information, regardless of the particular building service it performs. As a result, the BACnet protocol may be used by head-end computers, general-purpose direct digital controllers, and application specific or unitary controllers with equal effect.
Features Benefits Powerful network integration ♦ Communicate between dissimilar networks
♦ Shared database exchanges information from devices on both networks
♦ View diagnostics between both networks
Modbus TCP/IP protocol interface ♦ Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols
♦ Suitable for SCADA and "foreign device" interface applications
♦ Floating point data movement supported, including configurable support for Enron and Daniel® floating point applications
♦ Communicate with programmable controllers, intelligent devices, sensors and instruments
♦ Allows PCs and HMIs to monitor field devices
BACnet/IP Client ♦ Standard protocol for Building Automation and Control limited to Analog and Digital I/O commands
♦ Communicate with Building Automation controllers, HVAC, Fire and Safety equipment
♦ Support for Trane Building Control Unit (BCU)
Easy to Configure and Monitor ♦ Graphical drag-and-drop configuration tool for simple module configuration
♦ LED diagnostics for at-a-glance health check
♦ Easy to use diagnostics window with menu-driven hardware and protocol diagnostics
♦ View module database contents through serial connection to a desktop PC
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. The 5201-MNET-BACNET Setup Guide and sample configuration provide a quick and easy example with step-by-step instructions on how to move data from one network to the other.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
Modbus TCP/IP ProSoft’s Modbus TCP/IP implementation uses the module’s shared internal memory for data transfer. Sharing the memory with another protocol driver allows the module to transfer data between Modbus TCP/IP devices and other devices on other networks. Configurable floating-point data movement is supported, including support for Enron or Daniel® floating-point applications.
Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages.. • Supports five independent server connections for Service Port 502 (MBAP) • Supports five independent server connections for Service Port 2000 (Encapsulated) • Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up
to 64,000 bits in any combination of data types throughout the memory database • Modbus data types overlap in the gateway’s memory database, so the same data
can be conveniently read or written as bit-level or register-level data.
Modbus TCP/IP Client (Master) • Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP
or Encapsulated Modbus message formats • Offers one client connection with up to 100 commands to talk to multiple severs
Status Data Error codes, counters, and port status available
BACnet/IP Client • The BACnet driver supports a single UDP client to interface with one or more
devices that contain a BACnet/IP server • The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP
protocol primarily used with the Trane BCU • The module controls the read/write data transfer between the gateway and other
BACnet/IP devices
Functional Specifications Modbus TCP/IP Modbus Commands Supported (Client and Server)
1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
Configurable Parameters: (Client and Server)
Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset
Configurable Parameters: Client Only
Minimum Command Delay Response Timeout Retry Count Command Error Pointer
Command List Up to 100 fully-configurable Client commands Status Data Error codes reported individually for each command Command List Polling Each command can be individually enabled or disabled;
write-only-on-data-change is available
BACnet/IP Client The BACnet/IP (Building Automation and Control networking) protocol is designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, and air-conditioning control, lighting control, access control, and fire detection systems.
The BACnet/IP Client can be used to interface many different protocols with Ethernet-enabled BACnet devices.
Schematic
BACnet/IP General One client Command List Support for 100 commands, each configurable for
command, IP address, register to/from addressing and word/bit count.
Service Port 1 to 65535 Function Code 12=Read Single Property
14=Read Multiple Properties 15=Write Single Property 16=Write Multiple Property.
Data Type 0=Analog Input 1=Analog Output 3=Binary Input 4=Binary Output.
Point Count 1 to 25
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20 H x 2.07 W x 4.52 D inches (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 H x 2.73 W x 4.52 D inches (13.2 cm H x 6.934 cm W x 11.48cm D)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. isolation port to ground and port to logic
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Agency Approval & Certification UL/cUL ISA 12.12.01 Class I, Div 2 Groups A, B, C, D
cUL C22.2 No. 213-M1987
243333 183151
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information If you are unsure which product to select, please contact your local distributor. To order this product, please use the following:
Modbus TCP/IP to BACnet/IP Client Gateway 5201-MNET-BACNET
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe / Middle East / Africa [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2009. All Rights
Reserved. July 15, 2009
Specifications subject to change without notice.
Modbus TCP/IP to BOSCH Packaging Machinery Gateway 5201/5202-MNET-BSCH(4)
The MNET-BSCH modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate BOSCH Packaging Machinery devices into a system. The Modbus TCP/IP gateway in combination with the BOSCH Packaging Machinery device support, provides a very powerful interface to the many BOSCH devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to BOSCH Packaging Machinery Gateway 5201/5202-MNET-BSCH(4) The ProLinx Modbus TCP/IP to BOSCH Packaging Machinery Gateway creates a powerful connection between devices on an EtherNet/IP network and BOSCH packaging machinery. The module provides a single Ethernet port and up to four BOSCH configurable serial ports.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The BOSCH Master protocol driver supports Master implementations of the protocol on up to four ports. Each of the ports is individually configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
BOSCH Packaging Machinery The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc).
General Parameters Type Specifications
Internal Database 4000 registers (words) available BOSCH Modes Full-Duplex Error Checking BCC
BOSCH Master Driver Type Specifications
General Full-Duplex, Point to Point Configurable Parameters per Master port
Min Command Delay, Number of Commands, Response Timeout, Retry Count, Slave List Error Pointer
BOSCH Commands supported
0x00 Protected Write 0x01 Unprotected Read
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-BSCH 5202-MNET-BSCH4
Modbus TCP/IP to BOSCH Packaging Machinery Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus TCP/IP to CC-Link Local &
Intelligent Station Gateway 5209-MNET-CCLINK
ProSoft Technology's Modbus TCP/IP to CC-Link communication gateway allows Schneider Electric control platform users to integrate CC-Link Master compatible products with existing Modbus TCP/IP control networks.
The Modbus TCP/IP driver supports Schneider Electric processors as well most other devices that use Modbus TCP/IP. The driver allows Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. An optional web interface can be ordered separately to add FTP (ftp://) support.
The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.
Features Benefits Powerful network integration ♦ Communicate between dissimilar networks
♦ A shared 10.000-word database exchanges information from devices on both networks
♦ Allows integration of Modbus TCP/IP-based systems into a CC-Link Master-controlled network
Modbus TCP/IP ♦ Client and/or Server communication configurations supported
♦ Five simultaneous Server connections on TCP/IP Service Port 502 and five additional Server connections on any unreserved service port (typically TCP/IP Service Port 2000)
♦ One Client connection supports up to 100 commands to interface with processors or other Server-based devices
CC-Link Intelligent or Local Station
♦ Compatible with CC-Link Version 1.10
♦ Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity
♦ Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station
♦ As a Local Station, provides a read-only list of all network slaves’ cyclic and status data
♦ CC-Link Partner Association (CLPA) Certification
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.
General Specifications
ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation.
Modbus TCP/IP
ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks.
Floating point data movement is supported, including configurable support for Enron or Daniel® floating point implementations.
Modbus Server (Slave)
The server driver accepts incoming connections on Service Port 502 for clients using the Modbus TCP/IP MBAP message format and from clients on Service Port 2000 (or other Service Ports) for clients using the Encapsulated Modbus message format.
♦ Supports five independent server connections for Service Port 502
♦ Supports five independent server connections for Service Port 2000
♦ Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination
♦ Modbus data types overlap in the gateway's memory database, so the same data can be read or written as bit-level or register-level data, whichever is most convenient.
Modbus Client (Master)
♦ Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats
♦ Offers one client connection with up to 100 commands to talk to multiple severs
Status Data
Error codes, counters, and port status available
CC-Link
CC-Link (Control & Communication Link) is an open-standard communication protocol that enables easy connection to Mitsubishi and other Master controllers.
♦ CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide.
♦ The ProLinx CCLINK interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer.
♦ The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector.
Schematic
Functional Specifications
Modbus TCP/IP
Modbus Commands Supported (Server and Client)
1 : Read Coils 2 : Read Input Status 3 : Read Holding Registers 4 : Read Input Registers 5 : Force (Write) Single Coil 6 : Preset (Write) Single Holding Register 15 : Force (Write) Multiple Coils 16 : Preset (Write) Multiple Holding Registers
Configurable Parameters: Server
ProLinx IP Address Modbus data type starting address offsets
Configurable parameters: Client Min Command Delay Response Timeout Retry Count Command Error Pointer
Command List Up to 100 fully-configurable Client commands
Status Data Error codes reported individually for each command
Polling of command list Each command can be individually enabled or disabled; write-only-on-data-change is available
CC-Link CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing its I/O data transfer capacity.
Maximum Number of Occupied Stations
4 stations, consecutive addresses
Maximum Number of Devices per network
26-64 Devices depending on Local and Slave Stations configured
Device Types Supported Intelligent Device and Local Station
CC-Link Version supported CC-Link Version 1.10 cyclic data transmission
Message handling Cyclic Messages and Transient Messages
Cyclic Data Capacity 24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave
Additional I/O Data Transfer Capacity
Transient Messaging extends the data transfer capacity to more than 8,000 additional words
Transient Message Commands
System Information, Memory Access Information, RUN, STOP, Line Test. Memory Read and Memory Write commands
Communication speed 10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps
Transmission path format Bus format (EIA RS485 conformance)
Transmission format HDLC conformance
Error control system CRC (X16+X12+X5+1)
Conformance Testing Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.
Where Automation Connects Global Distribution We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at www.prosoft-technology. com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, and Ground terminals 2.5 mm screwdriver blade-sized terminals
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
General LED Indicators Power and General Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
CC-Link LED Indicators Run (Network Status) L Run (Data Link Execution) L Err (Data Link Comm Error) SD (Sending Data LED) RD (Receiving Data LED) ERR (Switch Setting Error)
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
CC-Link Interface Pin Description
DA Data Communication line A
DB Data Communication line B
DG Digital Ground
SLD Shield
FG Frame Ground
Shipped with Each Unit Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) CC-Link to Terminal Block connector
Agency Approval & Certification ISA
CC-Link Partner Association
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor.
Modbus TCP/IP to CC-Link Local Station & Intelligent Device Gateway 5209-MNET-CCLINK
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to http://www.prosoft-technology.com
Distributors:
Place your order by email or fax to:
North American / Latin American / Asia Pacific
[email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2013. All
Rights Reserved. 11/7/2013
Specifications subject to change without notice.
Modbus TCP/IP to Honeywell DE Master Gateway 5206-MNET-DEM
The MNET-DEM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate Honeywell DE slave devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa
DISCONTINUED Modbus TCP/IP to Honeywell DE Master Gateway 5206-MNET-DEM The ProLinx Modbus TCP/IP to Honeywell DE Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Honeywell DE slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and eight Honeywell DE Master configurable channels.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
+33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
Configurable Parameters
Modbus TCP/IP Client
Module IP Address Modbus address offsetting
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected]
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
Honeywell DE Master Specification Description The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
DE Communications • Built in accordance with the Honeywell DE
specification • Supports up to 8 single PV transmitters, 2
multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal
Assembly (FTA) with ProSoft-supplied cable • Supports redundant and non-redundant FTA
implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files
LEDs for Visual Module Status
DE Active DE Error
customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
Modbus TCP/IP to DF1 Master/Slave Gateway 5201-MNET-DFCM and 5202-MNET-DFCM4
The MNET-DFCM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DF1 devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to DF1 Master/Slave Gateway 5201-MNET-DFCM and 5202-MNET-DFCM4 The ProLinx Modbus TCP/IP to DF1 Master/Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The Modbus TCP/IP protocol driver supports Client and Server connections, connecting many different devices into Schneider Electric Quantum processors, as well other solutions supporting the protocol. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent
connections each to Modbus TCP/IP clients on Service Port 502 using the MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client General Actively reads and writes data with Modbus
TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Command parameters, Min Command Delay, Response Timeout, Retry Count, and more
Command List Up to 100 fully configurable commands on the Client port
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support; Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Full-Duplex or Half-Duplex Command List Up to 100 commands per Master port,
each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order these products, please use the following:
5201-MNET-DFCM 5202-MNET-DFCM4
(One DF1 Master/Slave Serial Port) (Four DF1 Master/Slave Serial Ports)
The 5201-MNET-DFCM-WEB is in a Final Sales Period of two years, effective October 14, 2008 until October 14, 2010. Thereafter, the product will continue to be supported until October 14, 2014. The recommended replacement for this product is 5201-MNET-DFCM. Only the WEB option version of this product is being discontinued.
For more information on the Product Retirement Program,please visit: http://www.prosofttechnology. com/products/product_retirement_program
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Modbus TCP/IP to EtherNet/IP Gateway
5201-MNET-DFNT
The ProLinx Modbus TCP/IP to EtherNet/IP Gateway creates a powerful connection between Modbus TCP/IP and EtherNet/IP networks. The module provides one Ethernet port. The Modbus TCP/IP driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP. This implementation allows both Client (Master) and server (slave) configurations using standard Ethernet TCP/IP connections. The gateway can use both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. The EtherNet/IP protocol supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a server, the EtherNet/IP port is a very powerful data transfer tool.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation protocols.
Specifications The Modbus TCP/IP driver allows multiple independent, concurrent Ethernet connections. The connections may be all Clients, all servers, or a combination of both Client and server connections.
Modbus TCP/IP Client Actively reads data from and writes data to Modbus TCP/IP devices using MBAP
One Client connection with multiple commands to talk to multiple servers
Modbus TCP/IP Server The server driver accepts incoming connections on Service Port 502 for Clients using Modbus TCP/IP MBAP messages and
connections on Service Port 2000 (or other Service Ports) for Clients using Encapsulated Modbus messages.
Supports multiple independent server connections for any combination of Service Port 502 (MBAP) and Service Port 2000 (Encapsulated)
Up to 20 Servers are supported
EtherNet/IP™ Server In server mode, the gateway accepts commands from one or more Clients to read/write data stored in the gateway’s internal registers. Number of Connections 5 Supported PLC Types PLC2, PLC5, SLC and ControlLogix file types
supported Internal Database Data Table File Size: 100 or 1000 words
Data Table File Start: N10 to N109 (based on file size set to 100) or N10 to N19 (based on file set to 1000)
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client In Client mode, the gateway controls the read/write data transfer between the gateway and other EtherNet/IP devices. Number of Clients Supported 1 Command List Support for 100 commands per Client, each
configurable for command type, IP address, register to/from addressing and word/bit count.
Polling of Command List User-configurable polling of commands, including disabled, continuous and on change of data (write only).
Other Configurable Parameters Number of Commands (up to 100 per Client) Min Command Delay Response Timeout Retry Count Command Error Pointer
Modbus TCP/IP Number of Clients Supported 1 Modbus Commands Supported (Client and Server)
1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
Configurable Parameters (Client and Server)
Gateway IP Address Modbus data type starting address offsets Floating-point start address and database offset
Configurable Parameters (Client Only)
Minimum Command Delay Response Timeout Retry Count Command Error Pointer
Command List Up to 100 fully configurable Client commands Status Data Error codes reported individually for each
command Command List Polling Each command can be individually enabled or
disabled; write-only-on-data-change is available
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information To order this product, please use the following:
Modbus TCP/IP to EtherNet/IP Gateway 5201-MNET-DFNT
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Distributors from the menu.
Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] Fax to +1 661.716.5101
Europe / Middle East / Africa [email protected] Fax to +33 (0) 5.61.78.40.52
Hardware Specifications Specification Description Power Supply 24 Vdc nominal
18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA maximum @ 32 Vdc maximum Operating Temperature -4°F to 122°F (-20°C to 50°C) Storage Temperature -40°F to 185°F (-40°C to 85°C) Relative Humidity 5% to 95% RH with no condensation Dimensions (Height x Width x Depth)
Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x 11.48 cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x 6.934 cm x 11.48 cm)
LED Indicators (On all gateways)
Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet protocol gateways only)
10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Port(s) (Serial protocol gateways only)
RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols.
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 3000 Vdc min. isolation port to ground and port to logic
Shipped WITH Each Unit
Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only)
Agency Approvals and Certifications ATEX CE cULus CB Safety
Where Automation Connects™ Global Distribution ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support We are there for you
All ProSoft Technology products are backed with free technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
www.prosoft-technology.com
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Copyright © 2014 ProSoft Technology, Inc., All rights reserved. 4/23/2014
Specifications subject to change without notice.
DH-485 to Modbus TCP/IP Gateway 5201-DH485-MNET
The DH-485-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a DH-485 device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DH-485 to Modbus TCP/IP Gateway 5201-DH485-MNET The ProLinx DH-485 to Modbus TCP/IP Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information
Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-DH485-MNET DH-485 to Modbus TCP/IP Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to DNP 3.0 Master Gateway 5201-MNET-DNPM
The MNET-DNPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DNP Master devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the DNP 3.0 Master device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to DNP 3.0 Master Gateway 5201-MNET-DNPM The ProLinx Modbus TCP/IP to DNP 3.0 Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and DNP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2
DNP Object Support DNPM Driver Manual contains full Object Definition documentation
DNP Master
Node address 0 to 65534 – software selectable
Slave count Up to 40 slave devices
Command count Up to 300 user defined commands to interface with remote slave devices
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-DNPM Modbus TCP/IP to DNP 3.0 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to DNP 3.0 Slave Gateway 5201-MNET-DNPS
The MNET-DNPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DNP Slave devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Modbus Processors (Modicon and many others). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to DNP 3.0 Slave Gateway
5201-MNET-DNPS The ProLinx Modbus TCP/IP to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Modbus network and DNP master devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-DNPS Modbus TCP/IP to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to DNP 3.0 over Ethernet Gateway 5201-MNET-DNPSNET
The MNET-DNPSNET modules are the ideal solution for joining Modbus TCP/IP and DNP over Ethernet networks. This Ethernet to Ethernet gateway is a powerful module designed with both Client and Server support for each protocol, enabling easy connections between the dissimilar network types. The module utilizes a shared database so that the two protocols can quickly and easily transfer data between themselves. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to DNP 3.0 over Ethernet Gateway 5201-MNET-DNPSNET The ProLinx Modbus TCP/IP to DNP over Ethernet Gateway creates a powerful connection between devices on Modbus TCP/IP and DNP over Ethernet networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port 20000. This port is fully configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
DNP 3.0 over Ethernet The DNP 3.0 over Ethernet driver provides support as a server using the TCP and UDP protocols using service port 20000.
General Parameters Internal Database Binary Inputs: 0 to 500 word count
Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 125 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Server – Level 2
DNP Server Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in (13.2H x 5.25W x 11.48D cm) Extended: 5.20H x 2.73W x 4.52D in (13.2H x 6.934W x 11.48D cm)
LED Indicators Power and Module Status Application Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Shipped with Each Unit Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5 mm screwdriver
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our website at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-DNPSNET Modbus TCP/IP to DNP 3.0 over Ethernet Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected] fax to +1 661.716.5101
[email protected] fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2017.
All Rights Reserved. August 11, 2017
Modbus TCP/IP to GE Ethernet Global Data Gateway 5201-MNET-EGD
The MNET-EGD modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The Modbus TCP/IP driver is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the GE Ethernet Global Data device support, the module provides a powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to GE Ethernet Global Data Gateway 5201 MNET-EGD The ProLinx Modbus TCP/IP to GE Ethernet Global Data Gateway creates a powerful connection between Modbus TCP/IP and GE Ethernet Global Data networks. The module provides one Ethernet port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections.
The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database. This common database provides the "backbone" communications for various field devices using different networks.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
EGD GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Specification Description
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-EGD Modbus TCP/IP to GE Ethernet Global Data Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe
fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2014. All Rights Reserved.
April 29, 2014
Modbus TCP/IP to HART Multi-drop Gateway 5207 MNET-HART
The MNET-HART modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate HART Multi-drop devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the more than two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to HART Multi-drop Gateway 5207-MNET-HART The ProLinx Modbus TCP/IP to HART Multi-drop Gateway creates a powerful connection between devices on an EtherNet/IP network and HART Multi-drop devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and four configurable HART channels.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters Communication parameters
Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver Command List Up to 100 fully configurable
commands per channel Polling of command list User configurable polling of
commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5207 MNET-HART Modbus TCP/IP to HART Multi-drop Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to HART Analog Gateway 5208-MNET-HART / 5228-MNET-HART
The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a Modbus TCP/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.
DATASHEET
Modbus TCP/IP to HART Analog Gateway
5208-MNET-HART / 5228-MNET-HART
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices.
One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
HART Analog The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the
use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
Communication parameters
Number of HART Preambles: 2 to 50Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
Isolated HART Analog Input Specifications
Input Range Current: 4 to 20mA with HART
Resolution 16bits
Input Filter First Order Sync: 10 Hz
Current Input Resistance 247.6 ohms +/- 1%
Open circuit detection time
1/2 second maximum
Over current +/-40mA continuous, maximum
Common Mode Noise Rejection
105dB
Calibrated Accuracy @ 25°C
4 to 20 mA: 0.05% of reading
Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated
24V DC Isolation Voltage 1500 VDC
HART® is a registered trademark of the HART Communication Foundation
Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications The ProLinx® Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 1-4 ch: 190 mA max@ 32 VDC max 5-8 ch: 250 mA max@ 32 VDC max
Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status HART Channel Activity (Green)
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
HART Interface Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel
Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Common Mode Rejection
105db @ DC
Over current +/- 40mA continuous, maximum
Overvoltage Protection
All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection
Accuracy 4 to 20 mA: 0.05% of reading @ 25°C
24VDC loop output power
1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power
Shipped with Each Unit
Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector
Certifications CE and ATEX
MTBF
5-Year PerformanceProbability
937,320 Hours
95.43%
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Compatible products in this product line also include:
EtherNet/IP to HART Analog Gateway
(5208-DFNT-HART / 5228-DFNT-HART)
DF1Master/Slave to HARTAnalog Gateway
(5108-DFCM-HART / 5128-DFCM-HART)
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following: 5208-MNET-HART / 5228-MNET-HART
Modbus TCP/IP to HART Analog Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to:
North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52 Specifications are subject to change without notice.
Copyright © ProSoft Technology, Inc. 2015.
All Rights Reserved. 2/25/15
Modbus TCP/IP to Modbus Master/Slave Gateway 5201/5202-MNET-MCM(4)
The MNET-MCM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate Modbus Master/Slave serial devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP Devices (Modicon processors and many others). In combination with the Modbus Master/Slave device support, the module provides a very powerful interface to the many Modbus Master/Slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to Modbus Master/Slave Gateway 5201/5202-MNET-MCM(4) The ProLinx Modbus TCP/IP to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Modbus serial devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server General Server supports up to 5 independent
connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client General Actively reads and writes data with Modbus
TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNET-MCM 5202-MNET-MCM4
Modbus TCP/IP to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to PROFIBUS DP Master Gateway 5204-MNET-PDPM
The MNET-PDPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system.
The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to PROFIBUS DP Master Gateway 5204-MNET-PDPM The ProLinx Modbus TCP/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB-9F port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5204-MNET-PDPM Modbus TCP/IP to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to PROFIBUS DPV1 Master Gateway 5204-MNET-PDPMV1
The MNET-PDPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system.
The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to PROFIBUS DPV1 Master Gateway 5204-MNET-PDPMV1 The ProLinx Modbus TCP/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB-9F port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices.
One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
PROFIBUS DP Master V1 The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.
• Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB)
• Project-unique GSD file import library • Monitoring and Modification of process data and DPV1 acyclic data • Multi-drop on a PROFIBUS DPV1 network drop with other compatible
devices
• Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network
• Automatic project documentation • Automatic Bus Parameter calculation • Online slave diagnostics • Supports all standardized baud rates, up to 12Mbps • Supports extended diagnostic data (DPV1) • Auto baud detection at all valid PROFIBUS DPV1 rates • Multiple modules can be placed in a single rack • CRC checksum determination of slave configuration consistency to
processor • Master Status LED Indicators for Operations, Network Drop
Communication, Master Token-Hold • FDT/DTM PROFIBUS master transport communication DTM software
included (see PSW-CDTM-PDPM)
PROFIBUS Master Specifications • Up to 125 Slaves can be connected with a repeater • Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words)
output data • Supports Extended Diagnostic Data • RS-485 optically isolated PROFIBUS Interface with on board DC-DC
converter • Acyclic communications (DPV1), Read and Write • Alarm Handling (DPV1) • Supports Sync and Freeze commands • Supports PROFIdrive 3.1 compliant parameter read and write
operations • Supports Multicast and Broadcast telegrams (DPV1)
PROFIBUS Master Port • DB-9F Optically Isolated RS-485 • Ready, Run, Error and Token LED Indicators • PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female
connector and isolated Opto-Couplers
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5204-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DPV1 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved. February 29, 2008
Modbus TCP/IP to PROFIBUS DP Slave Gateway 5205-MNET-PDPS
The MNET-PDPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to PROFIBUS DP Slave Gateway 5205-MNET-PDPS The ProLinx Modbus TCP/IP to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS DP Master device. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port and a single DB9F PROFIBUS port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters
PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5205-MNET-PDPS Modbus TCP/IP to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Modbus TCP/IP to Rockwell Automation Remote I/O Gateway 5210-MNET-RIO
The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP to Rockwell Automation Remote I/O Gateway 5210-MNET-RIO The ProLinx Modbus TCP/IP to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters
Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters
Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5210-MNET-RIO Modbus TCP/IP to Rockwell Automation Remote I/O Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DISCONTINUED
Modbus TCP/IP to Siemens 3964R Protocol Gateway
5202-MNET-S3964R4
The ProLinx® Modbus TCP/IP to Siemens 3964R Gateway allows point-to-point communication between a Modbus TCP/IP Ethernet network and 3964R serial communication partners.
The Modbus TCP/IP protocol driver supports Schneider Electric processors as well most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus messages. The Modbus TCP/IP implementation on this gateway has been specially developed to provide tight integration with 3964R protocol requirements.
The 3964R protocol was designed by Siemens for bi-directional data communication. It provides a point-to-point, serial interface connection that supports assigning high-priority or low-priority read and write access to each communication partner. This reduces initialization errors and improves data messages, increasing its versatility and range of possible applications.
Features Benefits
Powerful network integration ♦ Communicate between dissimilar networks
♦ Shared database exchanges information from devices on both networks
♦ View diagnostics between both networks
Modbus TCP/IP protocol interface ♦ Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols
♦ Suitable for SCADA and 'foreign device' interface applications
♦ Floating point data movement supported, including configurable support for Enron and Daniel® floating point applications
♦ Communicate with programmable controllers, intelligent devices, sensors and instruments
♦ Allows PCs and HMIs to monitor field devices
S3964R Protocol Interface (on four serial ports)
♦ Integrates with Schneider Electric baggage-handling projects using Siemens 3964R protocol
♦ Bi-directional data communication with communication partner high/low priority assignment
♦ Support simultaneous connections to as many as four 3964R communication partners
♦ Shares common database with Modbus TCP/IP network
Backed by ProSoft Technology® ♦ 20-year history of delivering high-quality, reliable solutions designed with you in mind
♦ Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
♦ Three-Year Warranty ensures reliability and protects against equipment failures
♦ Free ProSoft Software tools tightly integrated with our hardware...a simple and quick, total solution to help you make our products fit your applications
Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. The 5202-MNET-S3964R4 Setup Guide and sample configuration provide an quick and easy example with step-by-step instructions on how to move data from one network to the other.
General Specifications ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation.
Modbus TCP/IP ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks.
Configurable floating point data movement is supported, including support for Enron or Daniel® floating point applications.
Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages..
♦ Supports five independent server connections for Service Port 502 (MBAP)
♦ Supports five independent server connections for Service Port 2000 (Encapsulated)
♦ The Modbus TCP/IP implementation in this gateway has been specially designated to meet the unique requirements of the 3964R protocol. This provides a more tightly integrated solution for data transfer between the two protocols.
♦ Modbus data types overlap in the gateway's memory database, so the same data can be conveniently read or written as bit-level or register-level data.
Modbus TCP/IP Client (Master) ♦ Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP
or Encapsulated Modbus message formats
♦ Offers one client connection with up to 100 commands to talk to multiple severs
Status Data Error codes, counters, and port status available
S3964R
• Supported baud rates: 600 through 19200 are typical; up to 115200 is possible
• Supported protocols: 3964 with RK512, 3964 without RK512
• Priority setting to define the behavior of the protocol in case of an initialization conflict.
• Offers four independently configurable serial ports. Each port can communicate using 3964R protocol with or without RK512 formatting. Each port can be set to use an RS-232 or RS-422 serial signal interface. The ports operate independently from each other and each port is assigned its own space in the gateway's user memory database.
• When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can initiate or receive DB-SEND instructions.
• RK512 mode on Port 0, Port 1, Port 2, and Port 3 allow evaluation of RK512 header information: DB data block, DW data word, Coordination Byte 9, and CPU Coordination Byte 10.
• When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can send or receive standard communication telegrams (message packets).
• In either mode, 512 bytes is the maximum amount of data transferred per data transfer operation
• Data byte order can be swapped to support different device-specific word formats
• Communication activity indications and diagnostic information are available through LEDs and acknowledgment telegrams.
Schematic
Functional Specifications - Modbus TCP/IP Modbus Commands Supported (Client and Server)
Configurable Parameters: (Client and Server)
Configurable Parameters: Client
1 : Read Coils Status 2 : Read Input Status 3 : Read Holding Registers 4 : Read Input Registers 5 : Force (Write) Single Coil 6 : Preset (Write) Single Holding Register 15 : Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers
Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset
Minimum Command Delay Response Timeout Retry Count Command Error Pointer
Where Automation Connects Global Distribution
We think like you do
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at www.prosoft- technology.com
Global Support
We are there for you
Command List Up to 100 fully-configurable Client commands
Status Data Error codes reported individually for each command
Polling of command list Each command can be individually enabled or disabled;
write-only-on-data-change is available
Functional Specifications - S3964R
Ports 4 independent RS-232/422 serial application ports
Baud rates Typical: 600, 1200, 2400, 4800, 9600, 19200 bps
(available on all four ports) Additional Possible: 38400, 57600, 115200 bps (available only on Port 1, Port 2, and Port 3)
Parity Even, odd, None
All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email.
Global Offices
We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at www.prosoft- technology. com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Data bits 8
Stop bits 1
Maximum distance RS 232 - 15 cable meters
RS 422 - 1230 cable meters
Maximum Data Transfer
512 bytes per data transfer operation
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max @ 32 VDC max
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and General Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Configuration Serial Port
Mini DIN8 RS-232 only (Mini-DIN8/DB9M adapter included) No hardware handshaking
Ethernet Port 10Base-T half duplex RJ45 Connector
Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports RS-232/422/485
RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577
3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cable adapters
4 ft RS-232 null-modem DB9F configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor
Agency Approval & Certification
ISA ISA 12.12.01 Class 1 Div 2
CSA/cUL C22.2 No. 213-1987
243333
Copyright © ProSoft Technology, Inc. 2013. All Rights
Reserved. December 29, 2013
Specifications subject to change without notice.
Modbus TCP/IP Multi Client to EtherNet/IP Gateway 5201-MNETC-DFNT
The MNETC-DFNT modules are the ideal solution for the many applications where Modbus TCP/IP Client connectivity can be used to integrate EtherNet/IP devices into a system. The Modbus TCP/IP gateway is a powerful module designed with up to five Clients, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the EtherNet/IP device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus TCP/IP Multi Client to EtherNet/IP Gateway 5201-MNETC-DFNT The ProLinx Modbus TCP/IP Multi Client to EtherNet/IP Gateway creates a powerful connection between Modbus TCP/IP and EtherNet/IP networks. The module provides one Ethernet port.
The Modbus TCP/IP Multi Client protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNETC driver supports up to ten Client connections, and when coupled with the Web option provides a web/ftp interface as well.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
Modbus TCP/IP Multi Client The Modbus TCP/IP Multi Client driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP Client and other networks and devices.
Modbus TCP/IP Multi Client General Actively reads and writes data with Modbus
TCP/IP compatible devices. The MNET driver supports 5 MNET Modbus TCP/IP servers
(port 2000) 5 MBAP Modbus TCP/IP servers
(port 502) 10 Modbus TCP/IP clients (MNET or
MBAP), each supporting up to 16 Modbus TCP/IP commands.
The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks.
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 16 fully configurable commands on the Client port
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
Data File Data Table File Start – Fixed at N10 Data Table File Size – 100 or 1000 words
CIP Services Supported 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5201-MNETC-DFNT Modbus TCP/IP Multi Client to EtherNet/IP Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
September 27, 2007
PROFIBUS DP Slave to Honeywell DE Master Gateway 5306-PDPS-DEM
The PDPS-DEM modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate Honeywell DE slave devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the Honeywell DE support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa
DISCONTINUED PROFIBUS DP Slave to Honeywell DE Master Gateway 5506-PDPS-DEM The ProLinx PROFIBUS DP Slave to Honeywell DEM Gateway creates a powerful connection between devices on a PROFIBUS DP network and Honeywell DE slave device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and eight configurable Honeywell DE channels. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications
+33 (0) 5.34.36.87.20, support.EMEA@prosoft- Communication Baud Rate: 9.6 kbit/s – 12 Mbit/s
technology.com Languages spoken include: French, English
North America
parameters Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
+1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only)
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode
+1.281.298.9109, [email protected] Auto Baud Setting Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Configurable Parameters
PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal
Database
Honeywell DE Master Specification Description
The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
DE Communications • Built in accordance with the Honeywell DE
specification • Supports up to 8 single PV transmitters, 2
multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal
Assembly (FTA) with ProSoft-supplied cable • Supports redundant and non-redundant FTA
implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not
LEDs for Visual Module Status
DE Active DE Error
only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 13, 2013
PROFIBUS DP Slave to HART Multi-drop Gateway 5507-PDPS-HART
The PDPS-HART modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate HART Multi-drop devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the HART support, the module provides a very powerful interface to the more than two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
PROFIBUS DP Slave to HART Multi-drop Gateway 5507-PDPS-HART The ProLinx PROFIBUS DP Slave to HART Multi-drop Gateway creates a powerful connection between devices on a PROFIBUS DP network and HART field devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and 4 configurable HART Multi-drop channels.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART
channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5507-PDPS-HART PROFIBUS DP Slave to HART Multi-drop Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
PROFIBUS DPV1 Master FDT Communications DTM PSW-cDTM-PDPM
FDT (Field Device Tool) technology standardizes the communication interface between field devices and systems. The key feature is its independence from the communication protocol and the software environment of either the device or the host system. FDT allows any device to be accessed from any host through any protocol.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
PROFIBUS DPV1 Master PSW-cDTM-PDPM The PROFIBUS DPV1 Master FDT (Field Device Tool) communication DTM (comDTM) software is an interface between any compliant FDT software container, an FDT device DTM and applicable PROFIBUS slave devices.
The FDT PROFIBUS comDTM and a compatible FDT 1.2.1 frame application connect multiple device DTMs to their respective PROFIBUS connected field instruments using the Ethernet port on the PC and PROFIBUS DPV1 master module.
Typical FDT frame applications are Fieldcare (Endress + Hauser), PACTware (PACTware association) or fdtCONTAINER (MM-Software). The PROFIBUS DPV1 master modules support Class 1 and 2 services thereby allowing for PLC cyclic Class 1 services to co-exist with acyclic comDTM Class 2 services over the same network.
General Specifications General specifications for comDTM software include:
• Support for PTQ-PDPMV1 Ethernet port (no serial connectivity)
• Support for MVI56-PDPMV1 COM 2 serial port (no Ethernet connectivity, use Serial to Ethernet converter)
• FDT 1.2.1 compatible • Official FDT-JIG certificate • PROFIBUS-DPV1 master Class II operation (acyclic
master/slave services)
• PROFIBUS DPV1 Class II Services: o Initiate o Read o Write o Data transport o Abort
• Can be used to access Slaves concurrently as the master is scanning (Class I) the network I/O for the PLC.
• Supports many FDT containers such as FieldCare and PACTware.
• Built-in Ethernet and serial transport communication providers
• Software license provides full support of all configured device DTMs and communication of up to 15 master modules.
• Additional Functions performed: o Scan list function o Set Slave address
System Requirements • A ProSoft Technology PROFIBUS DPV1 Master
module with available user Ethernet or Serial port. • FDT v1.2.1 Frame program such as FieldCare or
PACTware. • Hardware Requirements (Recommended)
o Pentium 4 with 2 GHz Processor, 256 MB RAM o 450 MB disk space (for DTM Libraries) o Monitor 1024 X 768, 64k colors
• Software Requirements (Minimum) o Windows NT 4.0 Service Pack 6A, Windows
2000 SP3 or Windows XP o Microsoft Internet Explorer Version 6.0 o Microsoft Management Console* o Adobe Acrobat Reader 5.0*
*Some FDT Containers require these components
Additional Products ProSoft Technology offers a full complement of PROFIBUS DPV1 Master/Slave communication solutions for a variety of ProLinx Communication Gateways and PLC processor platforms:
PTQ-PDPMV1 ProTalk PROFIBUS DPV1 Master MVI56-PDPMV1 inRAx ControlLogix PROFIBUS DPV1
Master PCB ProSoft Configuration Builder. Software
required to configure all PROFIBUS DPV1 Masters and slaves.
ProLinx Gateways
Please visit our WEB site for listing of these products. http://www.prosoft-technology.com
Visit our web site or contact the factory for a complete and up-to-date list of available ProSoft Technology products.
Ordering Information To order this product, please use the following:
PSW-cDTM-PDPM PROFIBUS DPV1 Master FDT Communications DTM
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
April 26, 2007
Rockwell Automation Remote I/O to IEC 60870-5-101 Slave Gateway 5601-RIO-101S
The RIO-101S modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a Remote I/O master device into a system. The IEC60870-5-101 Slave gateway is a powerful module designed with Slave support, enabling easy connection to IEC 101 master devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to IEC 60870-5-101 Slave Gateway 5601-RIO-101S The ProLinx Rockwell Automation Remote I/O Adapter to IEC60870-5-101 Slave Gateway creates a powerful connection between devices on an IEC 101 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one IEC 101 Slave configurable serial port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
IEC 60870-5-101 Slave The 101S module acts as an input/output module between the IEC 60870-5-101 and other protocols and networks, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Storage of IEC time used in module is available in
the database • Protocol implementation conforms to the IEC 60870-
5-101 specification with fully configurable parameters
• Priority Queues • Invalid Bit Monitoring • Supports Balanced and Unbalanced Mode • Supports CP24 and CP56 time formats for events • Event generation configurable per point or data type
General Parameters Communication parameters
Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to 65535 ms
IEC 60870-5-101 Slave Configurable Parameters
Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-101S Rockwell Automation Remote I/O to IEC 60870-5-101 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to IEC 60870-5-103 Master Gateway 5601-RIO-103M
The RIO-103M modules are the ideal solution for the many applications where IEC 103 Master connectivity can be used to integrate a Remote I/O master or slave device into a system. The IEC60870-5-103 Master gateway is a powerful module designed with Master support, enabling easy connection to other IEC 103 devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O master or slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to IEC 60870-5-103 Master Gateway 5601-RIO-103M The ProLinx Rockwell Automation Remote I/O Adapter to IEC60870-5-103 Master Gateway creates a powerful connection between devices on an IEC 103 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one IEC 103 Master configurable serial port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
IEC 60870-5-103 Master The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).
The module supports:
• 16 slaves (sessions with distinct Data Link Addresses)
• Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses)
• Configurable Time Sync and General Interrogation messages during initialization
• Supports General Interrogation, General Command and Time Synchronization Commands.
General Parameters Communication parameters
Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
IEC 60870-5-103 Master Configurable Parameters
Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-103M Rockwell Automation Remote I/O to IEC 60870-5-103 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to ASCII Generic Serial Gateway 5601/5602-RIO-ASCII(4)
The RIO-ASCII modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate ASCII serial input devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with
DISCONTINUED Rockwell Automation Remote I/O to ASCII Generic Serial Gateway
5601/5602-RIO-ASCII(4) The ProLinx Rockwell Automation Remote I/O to ASCII Generic Serial Gateway creates a powerful connection between devices on a Remote I/O network and ASCII input devices. The module provides one Remote I/O port and up to four ASCII configurable serial ports.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Rack Number Addressing
0 to 63
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
Transmit and Receive buffer size
Transmit character with pacing
255 bytes each 0 to 65535 millisecond delay between each transmitted character.
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed
also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December18, 2013
Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED
Serial Activity and Error LED Status
Configuration Serial Port
Ethernet Port (Ethernet modules only)
DB-9M RS-232 only No hardware handshaking
RJ45 Connector Link and Activity LED indicators
Rockwell Automation Remote I/O to Honeywell DE Master Gateway 5606-RIO-DEM
The RIO-DEM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate Honeywell DE devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to Honeywell DE Master Gateway 5606-RIO-DEM The ProLinx Rockwell Automation Remote I/O Adapter to Honeywell DE Master Gateway creates a powerful connection between devices on a Remote I/O network and Honeywell DE slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and eight Honeywell DE Master channels.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module.
DE Communications • Built in accordance with the Honeywell DE
specification • Supports up to 8 single PV transmitters, 2
multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels
• Instrument database mismatch verification • Interfaces directly to Honeywell Field Terminal
Assembly (FTA) with ProSoft-supplied cable • Supports redundant and non-redundant FTA
implementations • Single cable connection from DEM module to FTA
Physical Specifications
Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power
LEDs for Visual Module Status
DE Active DE Error
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5606-RIO-DEM Rockwell Automation Remote I/O to Honeywell DE Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to DF1 Master/Slave Gateway 5601/5602-RIO-DFCM(4)
The RIO-DFCM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate DF1 Master/Slave devices into a system. The Remote I/O gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to DF1 Master/Slave Gateway 5601/5602-RIO-DFCM(4) The ProLinx Rockwell Automation Remote I/O Adapter to DF1 Master/Slave Gateway creates a powerful connection between devices on a Remote I/O network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and up to four serial ports.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters Communication parameters Local Station ID: 0 to 254
Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver DF1 Modes Full-Duplex – Master (Module generates
commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Specification Description Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-DFCM 5602-RIO-DFCM4
Rockwell Automation Remote I/O to DF1 Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to DH-485 Gateway 5601-RIO-DH485
The RIO-DH485 modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate Remote I/O devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to DH-485 Gateway 5601-RIO-DH485 The ProLinx Rockwell Automation Remote I/O Adapter to DH-485 Gateway creates a powerful connection between devices on DH-485 and Remote I/O networks. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and Remote I/O port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave.
General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to 19200 baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network.
DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
DH485 Functioning as a Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count
Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-DH485 Rockwell Automation Remote I/O to DH-485 Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to DNP 3.0 Master Gateway 5601-RIO-DNPM
The RIO-DNPM modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate Remote I/O serial devices into a system. The DNP Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to DNP 3.0 Master Gateway 5601-RIO-DNPM The ProLinx Rockwell Automation Remote I/O Adapter to DNP 3.0 Master Gateway creates a powerful connection between devices on a DNP 3.0 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one RIO port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points
DNP Mode DNP 3.0 Master – Level 2
DNP Object Support DNPM Driver Manual contains full Object Definition documentation
DNP Master
Node address 0 to 65534 – software selectable
Slave count Up to 40 slave devices
Command count Up to 300 user defined commands to interface with remote slave devices
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Specification Description
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-DNPM Rockwell Automation Remote I/O to DNP 3.0 Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway 5601-RIO-DNPS
The RIO-DNPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate DNP serial devices into a system. The RIO gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway 5601-RIO-DNPS The ProLinx Rockwell Automation Remote I/O Adapter to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Remote I/O network and DNP devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable serial port and one RIO port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters
Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 ms
DNP Mode DNP 3.0 Slave – Level 2
DNP Slave
Node address 0 to 65534 (software selectable)
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-DNPS Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to HART Multi-drop Gateway 5607-RIO-HART
The RIO-HART modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate HART Multi-drop devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED Rockwell Automation Remote I/O to HART Multi-drop Gateway
5607-RIO-HART The ProLinx Rockwell Automation Remote I/O Adapter to HART Multi-drop Gateway creates a powerful connection between devices on a Remote I/O network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and four configurable HART Multi-drop channels.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal,
Specification Description LED Indicators Power and Module Status
Application Status Serial Port Activity LED
Serial Activity and Error LED Status Configuration Serial Port DB-9M RS-232 only
No hardware handshaking Common Practice and Device Specific Commands. Each HART channel is independently configured to
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters Communication parameters Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable
RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL
1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility)
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in.
(13.2cmH x 6.934cmW x 11.48cmD)
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 18, 2013
Rockwell Automation Remote I/O to Modbus Master/Slave Gateway 5601/5602-RIO-MCM(4)
The RIO-MCM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate Modbus devices into a system. The Remote I/O gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to Modbus Master/Slave Gateway 5601/5602-RIO-MCM(4) The ProLinx Rockwell Automation Remote I/O Adapter to Modbus Master/Slave Gateway creates a powerful connection between devices on a Remote I/O network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and up to four serial ports.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol
Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master
Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave
Node address 1 to 247 – software selectable
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description Power Supply 24 VDC nominal
18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in.
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description Configuration Serial Port DB-9M RS-232 only
No hardware handshaking Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5601-RIO-MCM 5602-RIO-MCM4
Rockwell Automation Remote I/O to Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway 5604-RIO-PDPM
The RIO-PDPM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway 5604-RIO-PDPM The ProLinx Rockwell Automation Remote I/O Adapter to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Remote I/O network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and PROFIBUS DP Master configurable DB9F port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing
0 to 63
Rack Size ¼-rack, ½-rack, ¾-rack and full rack
Starting Group 0,2,4,6
Last Rack Yes or No
Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner
Supports I/O data movement. Amount determined by rack size configuration
BTW Command – up to 64 words
BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters
Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable.
Status Data Error codes, counters and port status available per configured slave on the network.
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Specification Description
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5604-RIO-PDPM Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
DATASHEET
Rockwell Automation® Remote I/O to PROFIBUS DP-V1 Master Gateway
5604-RIO-PDPMV1
The ProLinx® family Allen Bradley Remote I/O Adapter to PROFIBUS DPV1 Master communications module (5604-RIO-PDPMV1) creates a powerful connection between devices on a Remote I/O network and PROFIBUS slave devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Remote I/O port and a PROFIBUS DPV1 Master with a RS-485 9-pin D shell female connector interface with isolated Opto-Couplers.
The RIO interface is an adapter (slave) which can be connected to a RIO scanner (master) that controls the data transfer.
The PROFIBUS DPV1 Master (PDPMV1) protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. The DPV1 master supports FDT/DTM communication when using the PSW-cDTM-PDPM FDT communication DTM. The PROFIBUS DPV1 Master FDT communication DTM software is an interface between any compliant FDT software container, an FDT device DTM and applicable PROFIBUS slave devices.
The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in the industrial automation today.
Features Benefits Unique PROFIBUS DPV1 to A-B RIO standalone solution
Enhances existing A-B RIO networks in support distributed or remote PROFIBUS DPV1 I/O devices
FDT communication DTM compliant
Allows FDT Asset Management users to connect to field devices through Ethernet communications
Supported by ProSoft Configuration Software (PCB)
Supported by ProSoft Configuration Software (PCB)
Three Year Warranty Low risk investment with great cost savings, backed up by a better than average equipment failure protection plan, from the industrial communications experts who know protocols, devices, and automation
Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
General Specifications • Allows for legacy in-chassis PROFIBUS DPV1 master applications to
migrate to and/or sustain support for Allen-Bradley 1771 Remote I/O™. • ProSoft Configuration Builder (PCB) software with easy-to-use PROFIBUS
master network and gateway configuration. Sample PCB configuration file included.
• The gateway provides an Ethernet port and supports FDT/DTM Ethernet communications using the included communication DTM for use with FDT compliant software containers.
• The RIO gateway enables the migration of distributed PROFIBUS I/O without impacting existing Allen-Bradley Remote I/O networks.
• 24VDC Power supply for current loops is included. • 1771 PLC 5 Sample ladder logic provided • Sample PCB configuration file included
Functional Specifications
Remote I/O • Rack Number Addressing: 0 to 63 • Rack Size: ¼-rack, ½-rack, ¾-rack and full rack • Starting Group: 0, 2, 4, 6 • Last Rack: Yes or No • Baud Rate: 57.6K, 115K, 230K • Supports block-transfers of data with scanner • Supports I/O data movement. Amount determined by rack size
configuration • BTR Command - up to 63 words • BTW Command - up to 64 words
PROFIBUS DPV1 • Easy-to-use drag and drop Master Busview configuration interface via
ProSoft Configuration Builder software • Project-unique GSD file import library • Monitoring and Modification of process data and DPV1 acyclic data • Multi-drop on a PROFIBUS DPV1 network with other compatible devices • Automatic project documentation • Automatic Bus Parameter calculation • Online slave diagnostics • Supports all standardized baud rates, up to 12Mbps • Supports extended diagnostic data (DPV1) • Auto baud detection at all valid PROFIBUS DPV1 rates • CRC checksum determination of slave configuration consistency to
processor • Master Status LED Indicators for Operations, Network Communication,
Master Token-Hold and Network Configuration. • FDT/DTM PROFIBUS master transport communication DTM software
included (see PSW-CDTM-PDPM) • Up to 125 Slaves can be connected with a repeater • Up to 1536 cyclic bytes input and 1536 bytes output data • Supports Extended Diagnostic Data • RS-485 optically isolated PROFIBUS Interface with on board DC-DC
converter • Acyclic communications (DPV1), Read and Write • Alarm Handling (DPV1) • Supports Sync and Freeze commands • Supports PROFIdrive 3.1 compliant parameter read and write operations • Supports Multicast and Broadcast telegrams (DPV1)
Schematic
Hardware Specifications Specification Description
Power Supply 24 VDC nominal 18-32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 32 VDC max
Operating Temperature
-20 to 50 Deg C -4 to 122 Deg F
Storage Temperature -40 to 85 Deg C -40 to 185 Deg F
Relative Humidity 5-95% (w/o condensation)
Dimensions Standard 5.20H x 2.07W x 4.52D inches 13.2cmH x 5.25cmW x 11.48cmD Extended 5.20H x 2.73W x 4.52D inches 13.2cmH x 6.934cmW x 11.48cmD
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Configuration Serial Port
Mini-DIN RS-232 only No hardware handshaking
Ethernet Port 10Base-T Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
RIO Connector 3 pos screw-terminal adaptor(J803)
RIO LED Indicators Active - Green
PROFIBUS Connector DB-9F Standard PROFIBUS connector and isolated Opto-Couplers
PROFIBUS LED Indicators
Ready, Run, Error and Token LED Indicators
Shipped with each unit Mini-DIN to DB-9M cables per serial port 4 ft RS-232 configuration cable 2.5mm screwdriver CD (documentation and Configuration utility)
Regulatory Approvals ISA ISA 12.12.01 Class 1 Div 2
CSA/cUL C22.2 No. 213-1987
243333
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor.
Rockwell Automation® Remote I/O to PROFIBUS DP-V1 Master Gateway 5604-RIO-PDPMV1
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to http://www.prosoft-technology.com
Distributors:
Place your order by email or fax to:
North American / Latin American / Asia Pacific
[email protected], fax to +1 661.716.5101
Europe [email protected], fax to +33 (0) 5.61.78.40.52
Copyright © ProSoft Technology, Inc. 2000 - 2008. All
Rights Reserved.. 11/18/2008
Specifications subject to change without notice.
Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway 5605-RIO-PDPS
The RIO-PDPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP master device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway 5605-RIO-PDPS The ProLinx Rockwell Automation Remote I/O Adapter to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Remote I/O network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one PROFIBUS DP Slave configurable DB9F port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters
Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K
Functional Specifications
Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command – up to 64 words BTR Command – up to 63 words
Physical Connection
Remote I/O connector Standard 3-screw termination connector
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters
GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site
PROFIBUS Specifications
Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
General Specifications The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade
Current Load 500 mA max@ 24 VDC
Operating Temperature –20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status
Specification Description
Configuration Serial Port DB-9M RS-232 only No hardware handshaking
Ethernet Port (Ethernet modules only)
RJ45 Connector Link and Activity LED indicators
Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included
Serial Port Isolation 2500V RMS port signal isolation per UL 1577 3000V DC min. port to ground and port to logic power isolation
Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
5605-RIO-PDPS Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Wireless IEC 60870-5-104 Server Gateway 6201-WA-104S
The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 devices. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Wireless IEC 60870-5-104 Server Gateway 6201-WA-104S The ProLinx Wireless IEC60870-5-104 Server Gateway creates a powerful wireless connection between devices on an IEC 104 Server network.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
IEC 60870-5-104 Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers.
The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.
General specifications include:
• User-definable module memory usage • Protocol implementation conforms to the IEC 60870-5-104
specification with fully configurable parameters • SNTP (Simple Network Time Protocol) timestamping for detailed
logging of data transactions The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
IEC 60870-5-104 Server
Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels: user selectable 1 through 11* **
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports Two RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10-5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications
Specification Description Power Supply 24 VDC nominal, 18 to 32 VDC allowed.
Positive, Negative, GND Terminals.
Current Load 500 mA max@ 24 VDC Operating Temperature -20 to 50°C (-4 to 122°F) Storage Temperature -40 to 85°C (-40 to 185°F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Specification Description Configuration Serial Port Mini-DIN, RS-232 only
No hardware handshaking Ethernet Port RJ45 10Base-T Connector. Link and Activity
LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna ports Two RP-SMA connectors, with automatic antenna diversity.
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
6201-WA-104S Wireless IEC 60870-5-104 Server Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved. February 27, 2008
Wireless ASCII Generic Serial Gateway 6201-WA-ASCII
The WA-ASCII module is the ideal solution for the many applications where wireless connectivity can be used to integrate an ASCII generic serial input device into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe - Middle East - Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED Wireless ASCII Generic Serial Gateway
6201-WA-ASCII The ProLinx Wireless ASCII Generic Serial Gateway creates a powerful wireless connection between ASCII input devices.
The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).
The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both.
ASCII Specifications
Ports Available in up to four port configurations to receive and/or transmit data.
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only)
Transmit and Receive buffer size
Transmit character with pacing
255 bytes each
0 to 65535 millisecond delay between each transmitted character.
+1.281.298.9109, [email protected] Languages spoken include: Spanish, English
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each
other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications - Radio Modules These modules utilize a full function wireless network
Specification Description
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share
Configuration Serial Port
Application Serial Ports
Mini-DIN RS-232 only No hardware handshaking
Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder Channels: user selectable
1 through 11* ** ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports Two RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10-5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC
customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Wireless DF1 Master/Slave Gateway 6201-WA-DFCM
The WA-DFCM modules are the ideal solution for the many applications where wireless connectivity can be used to integrate DF1 devices into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED Wireless DF1 Master/Slave Gateway
6201-WA-DFCM The ProLinx Wireless DF1 Master/Slave Gateway creates a powerful wireless connection between DF1 Slave devices.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking BCC and CRC Miscellaneous Full hardware handshaking control,
providing radio, smart modem and Multi- drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
DF1 Master Driver
DF1 Modes Full-Duplex – Master (Module generates commands) Half-Duplex – Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver DF1 Modes Full Duplex – Slave (not peer mode)
Half Duplex – Polled
Specification Description
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words)
Configuration Serial Port Mini-DIN RS-232 only No hardware handshaking
Data Table location in database (0 to 3999)
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications – Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description Frequency 2.4 GHz band (2400 to 2483.5 MHz)* Wireless medium DSSS – Direct Sequence Spread Spectrum
(802.11b) Output power 32 mW (15 dBm) Channel data rates 11, 5.5, 2, 1 Mbps Channels – user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP
key rollover management Antenna Ports (2) RP-SMA connectors, automatic
antenna diversity Bit Error Rate (BER) Better than 10–5 * Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
Wireless EtherNet/IP Gateway 6201-WA-DFNT
The WA-DFNT modules are the ideal solution for the many applications where wireless EtherNet/IP connectivity can be used to integrate devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe - Middle East - Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED Wireless EtherNet/IP Gateway 6201-WA-DFNT The ProLinx Wireless EtherNet/IP Gateway creates a powerful wireless connection between devices on an EtherNet/IP network.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information Messaging PCCC on CIP
Explicit Messaging supported Miscellaneous 125 word read and write data lengths
Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications Connections Five independent TCP server sockets permit
remote clients to interact with all data contained in the module.
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications General One client Command List Support for 100 commands, each
configurable for command, IP address, register to/from addressing and word/bit count.
Polling of command list User configurable polling of commands, including disabled, continuous and on
change of data (write only).
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels: user selectable 1 through 11* **
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports Two RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10-5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals.
Current Load 500 mA max@ 24 VDC
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port Mini-DIN, RS-232 only No hardware handshaking
Ethernet Port RJ45 10Base-T Connector. Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per- second and less than or equal to 5 minutes duration
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna ports Two RP-SMA connectors, with automatic antenna diversity.
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products. Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Wireless EtherNet/IP to DF1 Master/Slave Gateway 6202-WA-DFNT-DFCM3
The WA-DFNT-DFCM modules are ideal for the many applications where wireless EtherNet/IP connectivity can integrate DF1 devices into a system. The EtherNet/IP gateway is designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs. With the DF1 Master/Slave device support, the module provides a powerful interface to the many DF1 devices in the industrial marketplace today. Data is exchanged between devices and/or networks using a shared common database and an efficient wireless protocol. This common database provides "backbone" communications for various devices using different networks. Applications are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe - Middle East - Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
DISCONTINUED Wireless EtherNet/IP to DF1 Master/Slave Gateway
6202-WA-DFNT-DFCM3 The ProLinx Wireless EtherNet/IP to DF1 Master/Slave Gateway creates a powerful wireless connection between devices on an EtherNet/IP network and DF1 devices.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User- configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool.
The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware.
General Protocol Information
Messaging PCCC on CIP Explicit Messaging supported
Miscellaneous 125 word read and write data lengths Floating point data supported
EtherNet/IP Server Specifications In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
EtherNet/IP Server Specifications
Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module.
DF1 Master Driver
DF1 Modes Full-Duplex - Master (Module generates commands)
Half-Duplex - Polling
Command List Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count
Data File Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
Polling of Command List
User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
CIP Services Supported
0x4C - CIP Data Table Read 0x4D - CIP Data Table Write
DF1 Slave Protocol Specifications
EtherNet/IP Client Specifications In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
EtherNet/IP Client Specifications
General One client
The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.
DF1 Slave Driver
DF1 Modes Full Duplex - Slave (not peer mode) Half Duplex - Polled
Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.
Configurable parameters per slave port
Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0
Polling of command list
User configurable polling of commands, including disabled, continuous and on change of data (write only).
to 3999)
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where
DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).
General Parameters
a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network
Communication parameters
Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 milliseconds
can produce these types of messages and each device determines which of these messages to consume.
General Specifications - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial
Error Checking BCC and CRC
Miscellaneous Full hardware handshaking control, providing radio, smart modem and multi-drop support Floating point data supported
DF1 Master Protocol Specifications The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.
applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Channels: user selectable
1 through 11* ** Additional Products ProSoft Technology® offers a full complement of
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports Two RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10-5
* Varies with country regulation ** Some European countries such as France allow fewer
hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals.
Current Load 500 mA max@ 24 VDC
Operating Temperature
-20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port
Application Serial Ports
Mini-DIN, RS-232 only No hardware handshaking
Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna ports Two RP-SMA connectors, with automatic antenna diversity.
Shipped with each unit
Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
Wireless HART Multi-drop Gateway 6207/6227-WA-HART(2)
The ProLinx High Speed Wireless to HART Multi-drop Gateways create a powerful connection between devices on an wireless network and HART Multi-drop devices. The module provides one wireless port and four HART Multi-drop channels. The ProLinx 6000 series of wireless gateways will provide users more flexibility than ever before seen in wireless solutions. Users will be able to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by selecting the appropriate protocol/network that provides a connection to the hardwire device, the protocol is then converted into a common radio packet, "ProSoft Wireless Protocol" (PWP) or to standard industry protocols such as HART to other wireless gateways in the system.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa +33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
DISCONTINUED Wireless HART Multi-drop Gateway
6207/6227-WA-HART(2) The ProLinx Wireless HART Multi-drop Gateway creates a powerful connection between devices on a wireless network and HART devices.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
General Parameters
Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Configurable Parameters per Channel
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
HART Driver
Command List Up to 100 fully configurable commands per channel
Polling of command list User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
HART® is a registered trademark of the HART Communication Foundation
General Specifications – Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS – Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels – user selectable 1 through 11* **
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports (2) RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10–5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Specification Description
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
HART HART modules ship with the necessary screw terminal adapters to connect your devices directly to the gateway. ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F) Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port Mini-DIN RS-232 only No hardware handshaking
Wireless Modbus Plus Gateway 6303-WA-MBP The WA-MBP modules are the ideal solution for the many applications where wireless Modbus Plus connectivity can be used to integrate devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others).Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless
DISCONTINUED Wireless Modbus Plus Gateway
6303-WA-MBP The ProLinx Wireless Modbus Plus Gateway creates a powerful wireless connection between devices on a Modbus Plus network.
The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.
General Parameters protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support
Modbus Function Codes
3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.)
All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa
Address Scope 1 to 64 Modbus Plus Functioning as a Master
Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count
+33 (0) 5.34.36.87.20, support.EMEA@prosoft- technology.com Languages spoken include: French, English
Polling of command list
Configurable polling of command list, including continuous and on change of data
North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish
Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English
Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Modbus Plus Functioning as a Slave
Node address 1 to 64 – software selectable
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless
bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
Specification Description
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
General Specifications – Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial
Configuration Serial Port
Application Serial Ports
Mini-DIN RS-232 only No hardware handshaking
Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS – Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not
Channels – user selectable
1 through 11* ** only a powerful solution for new configuration files, but also allows you to import information from previously
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports (2) RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10–5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC
installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Copyright © ProSoft Technology, Inc. 2000 - 2013. All Rights Reserved.
December 17, 2013
Operating Temperature
–20 to 50°C (–4 to 122°F)
Storage Temperature –40 to 85°C (–40 to 185°F)
Relative Humidity 5 to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
Wireless Modbus Master/Slave Gateway 6201-WA-MCM
The WA-MCM modules are the ideal solution for the many applications where wireless Modbus connectivity can be used to integrate devices into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Wireless Modbus Master/Slave Gateway 6201-WA-MCM The ProLinx Wireless Modbus Master/Slave Gateway creates a powerful wireless connection between devices on a Modbus network.
The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).
General Parameters – Modbus Protocol Communication parameters
Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Floating point data movement supported, including configurable support for Enron implementation
Function Codes 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register
Modbus Master Command List Up to 100 command per master port, each
fully configurable for function, slave address, register to/from addressing and word/bit count.
Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Modbus Slave Node address 1 to 247 – software selectable
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications – Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS – Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels – user selectable 1 through 11* **
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports (2) RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10–5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port Mini-DIN RS-232 only No hardware handshaking
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
6201-WA-MCM Wireless Modbus Master/Slave Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007
Wireless Modbus TCP/IP Gateway 6201-WA-MNET
The WA-MNET modules are the ideal solution for the many applications where wireless Modbus TCP/IP connectivity can be used to integrate devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Wireless Modbus TCP/IP Gateway 6201-WA-MNET The ProLinx wireless Modbus TCP/IP Gateway creates a powerful wireless connection between devices on a Modbus TCP/IP network.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server
General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000.
Configurable Parameters Module IP Address Modbus address offsetting
Modbus TCP/IP Client
General Actively reads and writes data with Modbus TCP/IP compatible devices.
One client connection (up to 100 servers/devices with 100 commands)
Configurable parameters Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer
Command List Up to 100 fully configurable commands on the Client port
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast
group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
Specification Description
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels: user selectable 1 through 11* **
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports Two RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10-5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals.
Current Load 500 mA max@ 24 VDC
Operating Temperature -20 to 50°C (-4 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port Mini-DIN, RS-232 only No hardware handshaking
Specification Description
Ethernet Port RJ45 10Base-T Connector. Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna ports Two RP-SMA connectors, with automatic antenna diversity.
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
6201-WA-MNET Wireless Modbus TCP/IP Gateway
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved. February 27, 2008
Wireless PROFIBUS Gateways 6104-WA-PDPM / 6105-WA-PDPS
The modules offer one-to-one or one-to-many PROFIBUS interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.
How to Contact Us: Sales and Support All ProSoft Technology® products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email:
Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English
Wireless PROFIBUS DP Gateways 6104-WA-PDPM 6105-WA-PDPS
PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.
General Parameters Communication parameters
Baud Rate: 9.6 kbit/s – 12 Mbit/s
PROFIBUS Master
Command List Read Diag Global Cmd Read Cntrs Reset Cntrs
Node address 0 - 125 – software selectable. Status Data Error codes, counters and port status
available per configured slave on the network.
PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters GSD File PRLX05A5.GSD
Downloadable from ProSoft Technology web site
PROFIBUS Specifications Communication parameters Baud Rate: 9.6 kbit/s – 12 Mbit/s Supported I/O length 244 bytes Input data
244 bytes Output data 400 bytes total
Supported PROFIBUS DP features
PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting
Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database
ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume.
General Specifications – Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications.
These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.
General Radio Specifications Specification Value
Frequency 2.4 GHz band (2400 to 2483.5 MHz)*
Wireless medium DSSS – Direct Sequence Spread Spectrum (802.11 b)
Output power 32 mW (15 dBm)
Channel data rates 11, 5.5, 2, 1 Mbps
Channels – user selectable 11 – North America 13 – Europe** 14 – Japan
Security PWP + WEP 64/128 Encryption with WEP key rollover management
Antenna Ports (2) RP-SMA connectors, automatic antenna diversity
Bit Error Rate (BER) Better than 10–5
* Varies with country regulation ** Some European countries such as France allow fewer channels
Hardware Specifications Specification Description
Power Supply 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals
Current Load 500 mA max@ 24 VDC Operating Temperature –20 to 50°C (–4 to 122°F)Storage Temperature –40 to 85°C (–40 to 185°F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches
(13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)
Specification Description
LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status
Configuration Serial Port Mini-DIN RS-232 only No hardware handshaking
Application Serial Ports Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included
Antenna Ports Two RP-SMA connectors, with automatic antenna diversity.
Port Isolation 2500V Opto-Isolators 500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports)
ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms.
Visit our web site at http://www.prosoft-technology.com for a complete list of products.
Ordering Information To order this product, please use the following:
6104-WA-PDPM 6105-WA-PDPS
Wireless PROFIBUS DP Master Wireless PROFIBUS DP Slave
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com
Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.
May 03, 2007