17
V IEC61850 & DDFR 10 th Nov. 2020 Distribution Management System

Distribution Management System · 2020. 11. 10. · Distribution Management System. Outline •Electricity System Network •Substation Structure •Modern Electricity System Network

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

  • VIEC61850 & DDFR

    10th Nov. 2020

    Distribution Management System

  • Outline

    • Electricity System Network• Substation Structure • Modern Electricity System Network• IEC61850 Communication Protocol • Digital Disturbance& Fault Recorder(DDFR)• Using IEC61850 & DDFR in MEDC Network

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Electricity System Network

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Substation Structure

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Substation Structure

  • Copper wire

    Communication

    Event Record

    &

    Analyses

    Relays

    medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Challenges

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Modern Electricity System Network

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    What Is IEC61850

    same communication

    Protocol

    IEC 61850 is High Speed Peer to Peer Ethernet communication protocol Used in electrical substations. It is a standardized method of communications

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    What Is The Purpose Of IEC61850

    Automation, Protection

    ,Control

    • Monitoring

    • Measurement

    • Recording

    • Communication

    Provide Platform

    Substation Equipment

    • Designing

    • Integrity

    • Maintaining

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    IEC61850 Infrastructure

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Features of IEC61850

    IEC61850

    • Reducing the overall system costs.

    • An open system for protection, automation and data sharing.

    • Increasing the power quality and reducing the outage response

    • Fast Peer –to-Peer communication.

    • Reduction of Hard Wires connection.

    • Reporting Features

  • Copper wire

    Communication

    Event Record

    &

    Analyses

    Relays

    medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Why should we consider IEC61850 Protocol

  • medcoman.comPowerTallKs ©Muscat Electricity Distribution Company

    Digital Disturbance& Fault Recorder(DDFR)

  • medcoman.comPowerTallks ©Muscat Electricity Distribution Company

    DDFR Infrastructure

  • Fast Event Record Communication with

    Relay

    Database Reduced Human Error

    medcoman.comPowerTallks ©Muscat Electricity Distribution Company

    Why we Need DDFR

    Decision Making

    Understand the Fault

  • medcoman.comPowerTallks ©Muscat Electricity Distribution Company

    Using IEC61850 & DDFR in MEDC Network

    1

    20

    5

    12%

    0

    5

    10

    15

    20

    25

    IEC61850 DDFR

    GRID Primary persentage