As a precaution, gloves and eye protection should be worn when handling drug substances and using test units.Do not puncture any part of unit. Do not remove probe once locked into unit.
In the unlikely event of a spill, rinse affected area thoroughly with water.Keep out of reach of children.
All results are presumptive. If necessary, further confirmatory testing by a competent drug testing lab may provide additional identification and quantification using gas chromatography/mass spectrometry analysis.
World Leader inForensic Products
DentaI Manufactured by IDenta Corp.www.identa-corp.com • +972-2-5872220
• Patented Technology Made in Israel
Tablets
Fi rmly p r e s s t he Smart-Tip™ on tablet while scrubbing in a circular motion until the tip is completely c o v e r e d w i t h substance.
Powders2R e m o v e t h e S m a r t - Ti p ™ probe from test unit.
1
Test
Pre
para
tion
Sample suspected substance.
T o u c h a d h e s i v e Smart-Tip™ to sample.
G e n t l y shake test unit for 2-3 seconds.
4With
, squeeze chamber 1 until capsule breaks.
thumb and forefinger 5
Cha
mbe
r 1 Id
entif
icat
ionLock Smart-
Tip™ probe into test unit. Press firmly.
3
Test
Pre
para
tion
Cham
ber 1
Res
ults
If the substance is a brown powder, the appearance of a red-violet color strongly indicates the presence of Brown Heroin.
If red-violet color develops, proceed to Disposal.If no color develops, Brown Heroin is not present. Proceed to step 7.
G e n t l y shake test unit for 2-3 seconds.
7With
, squeeze chamber 2 until capsule breaks.
thumb and forefinger 8
Cham
ber 2
Iden
tific
atio
nLock Smart-Tip™ probe into test unit. Press firmly.
6
Test
Pre
para
tion
Cham
ber 2
Res
ults If the substance is a powder, the appearance of a purple-violet
color indicates the presence of Heroin.
Proceed to Acid Dilution (steps 9-10),regardless of whether or not a color appeared.
If no color develops, neither Heroin nor Morphine are present.
Disp
osal The test kit
is now safe to dispose of in the trash.
Aci
d D
ilutio
n 9 10Withsqueeze chamber 3 until capsule breaks. , thumb and forefinger Gently shake test unit for 2-3 seconds.The test window will warm up.This is normal.
If the substance is a tablet, the appearance of a purple-violet color indicates the presence of Morphine.
99% accurate presumptive field screening when used correctly.
If the suspected substance is a , proceed to .If the suspected substance is a or a , proceed to .
brown powdersteps 3-5
white powdertablet steps 6-10
White Heroin - Morphine testing: If Capsule 1 was broken by mistake, it will have no effect. Continue and follow the regular steps of the procedure.
Do not continue
unless probe is locked below the Flex Pins and cannot be removed from the test unit.
A click sound will indicate the probe is
locked.
Do not continue
unless probe is locked below the Flex Pins and cannot be removed from the test unit.
A click sound will indicate the probe is
locked.
IDenta Heroin (Brown & White) - Morphine Substance
DRUG TESTING KIT
Procedure Card for IDT 2200
READ BEFORE USE
10-13