Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
Series SYJ3000/5000/7000
4, 5 Port Solenoid ValveRubber Seal
SYJ3000
SYJ5000
SYJ7000
Series VJ
VJ3000
VJ5000
VJ7000
Low power consumption: 0.5W(Without light)(Current draw: 21mA at 24V DC)
Bright colour tone and state of the art design
Standard valve suitable for copper free applications
Completely interchangeable with the previous series VJ3000/5000/7000 and VZ3000/5000Mounts on the same sub-plates and manifolds as
the VJ3000/5000/7000 and the VZ3000/5000.
Series VZ
—
VZ3000
VZ5000
Choice of pilot exhaust styles
1.3-1
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Port sizeEffective areamm2(Nl/min)
SYJ3000
SYJ5000
SYJ7000
SYJ3000
SYJ5000
SYJ7000
Variations
Series
Grommet
DC
With surge voltagesuppressor
Actuation
SingleDouble
2 position
Closed centreExhaust centrePressure centre
3 position
Voltage Electric entry
Option
Light and surgevoltage suppressor
Manualoverride
M3 : 0.9(49.08)
M5 X 0.8: 3.6(196.30)C4 : 3(166.86)C6 : 3.4(169.39)
1/8: 11(588.90) C6: 8.6(471.12)
C8: 9.9(539.83)
M5 : 1.8(98.15)
1/8: 4.5(245.38)
1/8, 1/4: 12.6(687.05)
24V DC12V DC
6V DC5V DC3V DC
DC
L plugconnector
M plugconnector
With light and surgevoltage suppressor
Non-lockingpush style
Push-turn-locking slotted style
Bo
dy
po
rted
Bas
e m
ou
nte
d
Series SYJ3000/5000/7000
4, 5 Port Solenoid ValveRubber Seal
1.3-2
SYJ3000
SYJ5000
SYJ7000
SYJ3000
SYJ5000
SYJ7000
M3
Manifold Variations
Valve seriesA, B portlocation
A, B port size
With built-in One-touch fitting
Applicable tube O.D.1/8M5
ø4 ø6 ø8
Manifold options
IndividualSUP spacer
ass'y
IndividualEXH spacer
ass'y
Interfaceregulator
Flat cable manifold
Base mounted
Body ported Individual SUP spacer ass'y
Individual EXH spacer ass'y
Interface regulatorMixed mounting of 3 port valves and 4, 5 port valves
21P Type
P
R1
R2
4, 5 Port3 Port
32P Type
A, B port
R port
P port
A, B port
R port
P port
A, B port
R port
P port
A, B port
P port
R port
A, B port
P port
R port
P port(regulation)
Top
Side
Bottom
Side
Bottom
Side
Bottom
· Refer to p.1.3-21 for SYJ3000, p.1.3-44 for SYJ5000 and p.1.3-65 for SYJ7000.
P port(regulation)
Body
por
ted
Bas
e m
ou
nte
d
1.3-3
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000/5000/7000
SYJ3000, SYJ300······································P.1.3-21SYJ5000, SYJ500······································P.1.3-44SYJ7000, SYJ700······································P.1.3-65
Operation of Manual OverrideWarning
Use caution since manual override operation will operate any connected actuators.
Common Exhaust Port for the Pilot and Main ValveCaution
Series SYJ3000/5000/7000 and SeriesSYJ300/500/700 can be mounted on thesame manifold.How to mount on the same manifold is shown on thefollowing pages.
�Non-locking push style[Standard]
�Push-turn-locking slotted style[D]
Press in the direction of arrow.
While pressing, turn in the direction of the arrow.If you do not turn, the mechanism does not lock.
A second manual override is located on the pilot valve assembly. It is only available as a non-locking push style. Simply depress in the direction of the arrow.
Note)
How to Use Plug Connector
�Connection Push the connentor straight onto the pins of the solenoid, making sure the lip of the lever securely "locks" into the groove of the solenoid cover.�Disconnection Press the lever against the connector housing and pull it outward from the solenoid.
Strip 3.2 to 3.7mm of the lead wire ends, insert each stripped wire into a socket and crimp it using a special crimping tool.Be careful that the outer insulation of the lead wires does not interfere with the socket contact part.(Contact SMC for special crimping tools.)
qConnection/Discconnection of connector
wCrimping connection of lead wire and socket
eConnection/Disconnection of socket with lead wire�Connection
Insert lead wire and crimped socket into square holes (indicated as positive or negative) of connector. Press the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked position by lightly pulling on the lead wire.
In case that 4 or 5 port valve is used as 3 port valveSeries SYJ 3000, 5000, 7000 may be used as a N.C.or N.O. 3 port valve by plugging one of the A,B ports.Be sure not to plug the exhaust ports. Can be used when adouble solenoid, 3 port valve is required.
Plug position
Configuration
Num
ber
of
sole
noid
s
Sin
gle
Dou
ble
B port
N.C.
A port
N.O.
(JIS Symbols above: Series SYJ5000)
Locked position
Connector housing
Lead wire
Socket
Hook
Lead wireSocket
Crimping areaCore wire contact area
Hook Insulation
Max cover diameter: ø1.7mm
0.2 to 0.33mm2Core Wire
Plug Plug
(A)4
5(R1)
1(P)
3(R2)
(B)2
(A)4
5(R1)
1(P)
3(R2)
(B)2
(A)4
5(R1)
1(P)
3(R2)
(B)2
(A)4
5(R1)
1(P)
3(R2)
(B)2
Plug Plug
PUSHLO
CKCover
GroovePin
CoverGroovePin
Connectorhousing
Lever
DC indicator
Hook
SocketDXT170-71-1
Lead wire
Caution
Caution
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
Precautions
�DisconnectionTo remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screw driver (or similar). If the socket is to be re-used, reposition the hook again.
Pilot air is exhausted through the main valve body ratherthan directly to atmosphere.�Suitable for applications where exhausting the pilot valve to
atmosphere would be detrimental to the surrounding working environment.
�For use in extremely dirty environments where there is thepossibility that dust could enter the pilot exhaust anddamage the valve.
Ensure that the piping of exhaust air is not too restrictive.
1.3-4
Series SYJ3000/5000/7000
Plug Connector Lead Wire Length
Standard length is 300mm, but the following length is also available.
How to Order Connector Assembly
For DC:
How to OrderTo order a valve with lead wire length of other than 300mm, indicate part numbers of the valve without connector and the required connector ass'y separately.(Example)2000mm lead wire length
SY100 30 4A
Without lead wire: SY100 30 A
Lead wire length— 6101520253050
300mm600mm
1000mm1500mm2000mm2500mm3000mm5000mm
For DCSYJ3120-5LO-M3SY100-30-4A-20
With surge voltage suppressor (�R)
(–)(+)
(+)(–)
Zener diode
Zener diode
�Non polar
Indicator light and surge voltage suppressor (�U)
Please correctly connect the lead wires to (positive) and (negative) indications on the connector.For non-polar type,the lead wires can be connected to either one.For DC voltages other than 12, 24 incorrect wiring will cause damage to the surge suppressor circuit. (Wrong polarity will cause trouble).Solenoids, whose lead wires have been pre-wired, are positive side red and negative side black.
Caution
Coi
lC
oil
(–)(+)
(+)(–)
(with connector and 2pcs. of socket)
Surge Voltage Suppressor
Grommet, L and M plug connectorFor DC
With surge voltage suppressor (�S)�Standard (With polarity)
Red (+)
Black (–)
Diode to prevent reverse connection
Coi
l
Indicator light and surge voltage suppressor (�Z)
Diode to prevent reverse connection
LED
Caution
Dio
de
Red (+)
Black (–)
Coi
l
1.3-5
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000/5000/7000
Connector Ass'y with Protective Cover
Connector ass'y with protective cover enhances dust protection.Effective in preventing possible short circuit problems due to contaminants in contact with connector section.Cover material is chloroprene rubber which has excellentweatherability and electric insulation properties. Howeverbe careful not to allow contact with cutting oil.
How to Order
SY100 68 A
Lead wire length
6101520253050
300mm600mm
1000mm1500mm2000mm2500mm3000mm5000mm
Connector Ass'y with Cover/Dimenions
Flat Cable Manifold
With the flat cable manifold, each valve is wired to the manifold base. A single MIL flat cable connects theentire manifold to your power source. This greatly reducesinstallation time.
Type 21P Type 32P
Internal wiring of manifold
Note) Terminal number is not indicated on the connector.The terminal number is indicated on the connection schematic of connector, as show in the reference,means a relation of 1, 2, 3........26 from the triangle mark side on the flat cable of connector.
For more than 10 stations, both poles of the common should be wired.
For single solenoid, connect to the solenoid B side.
The maximum number of stations is 12. If more than 12 stations are
required, consult SMC.
Only non-polar valves are available for the flat cable manifold, therefore,
either negative COM or positive COM wiring of the manifold is possible.
BracketFor bracket attached styles of SYJ3000 (Single) and SYJ7000, do not use it without bracket.
Red
Gray
Black
(40)
(8)
(14.5) L
(8)
12ststation
Coil
Triangle mark
indicated position
Note) Connector
135723
24
25
262468
Triangle mark 123
242526Reference
4ststation
3rdstation
2ndstation
1ststation
12thstation
4thstation
3rdstation
2ndstation
1ststation
Connectedon the printedboard
(Max. 12 stations)
Caution Caution
Caution
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
How to Order Connector Ass’y with Protective CoverSpecify the part numbers of the solenoid valve without connector and the connector ass’y with protective cover separately.
EX.1) In case of 2000mm of lead wire
SYJ3120-5LOZ-M3
SY100-68-A-20EX.2) In case of 300mm of lead wire (Standard)
SYJ3120-5LPZ-M3
Symbol of connector ass’y with protective cover
It is not necessary to indicate the part number of connector ass’y with protective cover separately in this case.
Precautions
(–)
Sol
enoi
d A
(–)
Sol
enoi
d B
(+)
Com
mon
(+)
Com
mon
(–)
Sol
enoi
d A
(–)
Sol
enoi
d B
(–)
Sol
enoi
d A
(–)
Sol
enoi
d B
(–)
Sol
enoi
d A
(–)
Sol
enoi
d B
(–)
Sol
enoi
d A
(–)
Sol
enoi
d B
Solen
oid A
Solen
oid B
Solen
oid A
Solen
oid B
Solen
oid A
Solen
oid B
Solen
oid A
Solen
oid B
Solen
oid A
Solen
oid B
∗
(ø4.
1)
(6.5
)
(10)
1.3-6
Series SYJ3000/5000/7000
Interface Regulator
Installing an interface regulator between a valve and the manifold base makes it possible to reduce the supply pressure to that valve without changing the supply pressure of the other stations on the manifold.SpecificationsInterface regulator
Applicatable solenoid valve
Regulating port
Proof pressure
Max. operating pressure
Setting pressure range
Ambient and fluid temperature
Thread size for connection
of pressure gauge
Weight (kg)
Effective area at supply side(mm2)S at P1-0.7MPa, P2 = 0.5MPa
Effective area at exhaust side (mm2)S at P2 = 0.5MPa
(3)
(3)
P
P
A
B
A
B
EA
EB
ARBYJ5000
SYJ5000
P
1.5MPa
1.0MPa
0.05 to 0.7MPa
5 to 60°C
M5 X 0.8
0.06
1.9
2.1
4.5
4.5
ARBYJ7000
SYJ7000
P
0.09
5.1
5.8
12.6
12.6
(2)
(1)
Note 1) Set the pressure within the operating pressure range of the solenoid valve.Note 2) The maximum operating temperature for the valve is 50°C.Note 3) The effective area listed is for a single solenoid 2 position valve mounted on a sub-plate.Note 4) The interface regulator is only capable of regulating the "P" port pressure.
Flow rate (P A)�ARBYJ5000-00-P
�ARBYJ7000-00-P
0.6
0.5
0.4
0.3
0.2
0.1
0 50 100 150 2000
0.6
0.5
0.4
0.3
0.2
0.1
00 100 200 300 400
Flow rate (l/min(ANR))
Sec
onda
ry p
ress
ure
(M
Pa)
Caution
Flow rate (l/min(ANR))
Sec
onda
ry p
ress
ure
(M
Pa)
Condition: Supply pressure 0.7MPa
1.3-7
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000/5000/7000
Series SYJ3000
4, 5 Port Solenoid ValveRubber Seal
SYJ312�SYJ322�SYJ332�SYJ342�SYJ352�SYJ314�SYJ324�SYJ334�SYJ344�SYJ354�SYJ313�SYJ323�SYJ333�SYJ343�SYJ353�
M3
M5
0.9(49.08)
1.8(98.15)
1.2(65.76)
Gromet
33
47
50
59(33)
73(47)
76(50)
33
47
50
3551
54
61(35)77(51)
80(54)
3551
54
Model
Fluid
Configuration Port sizeEffective
areamm2(Nl/min)
Weight (g)L/M
plug connector
Specifications
Valve model
5 portBody ported
5 portBase mounted(With sub-plate)
4 portBase mounted(For manifold use only)
Operating pressure range(MPa)
Ambient and fluid temperature °C
Response time (ms) at 0.5MPa
Max. operating frequency (Hz)
Manual override
Pilot exhaust
Lubrication
Mounting position
Impact/Vibration resistance (m/s2 )
Protection structure
Solenoid SpecificationsElectrical entry
Coil rated voltage (V)
Allowable voltage
Power consumption (W)( 6)
Surge voltage suppressor
Indicator light
Grommet(G)/(H), L plug connector(L),M plug connector(M)
24, 12, 6, 5, 3
±10% rated voltage
0.5 (With light: 0.55)
Diode
LED
Note 1) In case of M5 and mounted on manifold base.Note 2) ( ): Without sub-plate.
2 position
3 position
2 position
3 position
2 position
3 position
Single
Double
Closed centre
Exhaust centre
Pressure centre
Single
DoubleClosed centre
Exhaust centre
Pressure centre
Single
Double
Closed centre
Exhaust centre
Pressure centre
2 position single
2 position double
3 position
2 position single, double
3 position
2 position single, double
3 position
Air
0.15 to 0.7
0.1 to 0.7
0.2 to 0.7
Max. 50
≤15
≤30
10
3
Non-locking push type, Push-turn-locking slotted style
Individual pilot exhaust, Common exhaust (pilot and main valve)
Not required
Free
150/30
Dust proof
Note 6) At rated voltage
DC
2 position sinle
2 position double
(B)2
1(P)
1(P)
3(R)
3(R)
5(R)
(A)4
(B)2
(A)4
1(P)
3(R)
(B)2
(A)4
1(P)
3(R)
(B)2
(A)4
1(P)
3(R)
(B)2
(A)4
1(P)
3(R)
(B)2
(A)4
(B)2
1(P)
3(R)
5(R)
(A)4
(B)2
1(P)
3(R)
5(R)
(A)4
(B)2
1(P)
3(R)
5(R)
(A)4
(B)2
1(P)
3(R)
5(R)
(A)4
2 position sinle
2 position double
3 position closed centre
3 position exhaust centre
3 position prssure centre 3 position prssure centre
3 position exhaust centre
3 position closed centre
JIS Symbol5 Port 4 Port (manifold)
Body ported
Base mounted
(4)
P.1.2-72OrderMade
(5)
(2)(1)
— (1)
Note 4) According to dynamic performance test JIS B8375-1981 (Coil temperature 20°C, at rated voltage, without surge voltage suppressor)
Note 5) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. (Value in the initial stage)
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000Hz.Test was performed at both energized and de-energized states to axis and right angle direction of the main valve and armature. (Value in the initial stage)
DC
1.3-8
CJ2 CylinderCylinder bore size (mm)
Bracket Mounting Cylinder Maximum Operating SpeedqInsert the lower hook of the mounting bracket into the groove on the bottom of the valve as shown.
wPress the valve and mounting bracket together until the upper hook of the bracket snaps into place in the groove on top of the valve.
Max
. op
erat
ing
spee
d (
mm
/s)
CM2 Cylinder
�System Figure q
Operating conditions) Pressure: 0.5MPa, Load rate: 50%At cylinder extended, cylinder stroke CJ2: 60mm
CM2: 300mmSystem components
System Solenoid valve
SYJ3000M5
(S = 1.8mm2)
AS1301F-M5-04
AS1301F-M5-06
AS2301F-01-06
AS2001F-06
Silencer
AN120-M5(S=5mm2)
Fitting(Tube O.D. X Port size)
ø4 XM5
ø6 XM5
ø6 X1/8
ø6 XM5
ø6 XM5
SysytemFigure
Solenoid valve
Silencer
Fitting
Speed controllerFittingSolenoid valve
Silencer
Fitting
Speed controller
700
600
500
400
300
200
100
6 10 16 20 25 32 40
A
D
B
C
A
Piping length1m
Piping length 5m
Speed controller
�System Figure wA
ir cy
linde
r
Air
cylin
der
�
�
�
�
q
w
1.3-9
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
SYJ3 3 5 M
SYJ3 4 M
2
2
12345
2 positon single solenoid2 positon double solenoid3 positon closed centre3 positon exhaust centre3 positon pressure centre
5
0
0
SYJ3 2 5 M1 M30
Single Double56VSR
9
24V DC12V DC6V DC5V DC3V DC
Less than 50 VDC
R Port P, E Port
Manifold type31, S31, 32, S32
5 port
(For manifold type 20)
Body ported
Base mounted(4 port)
Base mounted(5 port)
5 port
For sub-plate,Manifold type41, S41, 46, S46
4 port Port size
(With gasket and screws)
M5: With M5 port sub-plate
Manual override
—: Without sub-plate—: Non-locking push style
D: Push-turn-locking slotted style
Configuration—SZU
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
Light and surge voltage suppressorBracket
—: Without bracketF: With bracket
How to Order
Body option
0: Individual exhaust for the pilot valve
3: Common exhaust for the pilot and main valves
Rated voltageFor DC
Note)
R Port P, E Port
Electrical entry
G: 300mm lead wire
L: 300mm lead wire
M: 300mm lead wire
MN: Without lead wire
H: 600mm lead wire
LN: Without lead wire
LO: Without connector
MO: Without connector
LN and MN types are with 2 sockets.
24, 12, 6, 5, 3V DCGrommet L plug connector M plug connector
(For manifold use only.)
∗
�The double solenoid mounting bracket is supplied unattached.
�To order the double solenoid bracket for use with a single solenoid valve, order the single solenoid valve without a bracket and order the double solenoid bracket separately.Example) SYJ3120-5M-M3,
VJ3000-13-1
Protective classclass III (Mark: )
Contact SMC for other voltages (9)OrderMade
-Q
-Q
-Q
1.3-10
Series SYJ3000
SY114
—SZU
56VSR
GHL
LNLOM
MNMO
Construction
Component Parts Replacement PartsNo. Description Material
Zinc die castResinResinResin
Notewhitewhitewhite
No. NoteZinc die cast
Part No.SYJ3000-22-1-Q
SY114-���
How to Order Pilot Valve Assembly How to Order Connector Assembly
5 G
Electrical entry
24V DC12V DC6V DC5V DC3V DC
Light and surge voltage suppressor
Voltage
Grommet (Lead wire length: 300mm)Grommet (Lead wire length: 600mm)
With lead wireWithout lead wireWithout connectorWith lead wireWithout lead wireWithout connector
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
DC
Without lead wire
(with connector and 2pcs. of socket)
: SY100-30-4A-
:SY100-30-A
—6101520253050
300mm 600mm1000mm1500mm2000mm2500mm3000mm5000mm
Lead wire length
2 position single 2 position double
3 position closed centre/exhaust centre/pressure centre
(A)4
5(R)
3(R)
1(P)
(B)2
(A)4
5(R)
3(R)
1(P)
(B)2
(A)4
5(R)
3(R)
1(P)
5(R)
3(R)
1(P)
5(R)
3(R)
1(P)
(B)2
(A)4
(B)2
(A)4
(B)2
3 position closed centre
3 position exhaust centre
3 position pressure centre
R P R
A B
R P R
A B
R P R
A B
(This construction shows a closed centre.)
BodyPiston plateEnd coverPistonSpool Ass'y
DescriptionSub-platePilot valve
L plugconnector
M plugconnector
qwert
yu
e t q rw
w t q r
u
u
w q t r
y
u
-Q
-Q
1.3-11
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Grommet (G), (H): SYJ3120-� ��-M3-Q
L plug connector (L): SYJ3120-�L��-M3-Q
2 Position Single
With bracket
Other dimensions are the same as the grommet style.
Other dimensions are the same as the grommet style.
G: ≅ 300H: ≅ 600
(Lead wire length)
54.4 (GZ, GS: 55.1)
49.5
15
13.520
R RP
15
7 7
1011
5-M3
(Piping port)
(Non-locking)Manual override
15.6
9
28
56.4
(G
Z, G
S: 5
7.1)
51.5
2
20
15(Bracket)
15.6
9
28
54.7
49.5
15
20
13.5
8.2 4
2-ø1.8(Mounting holes for manifold)
BA
11.5 7
33.5
13.2 7.1
50.7
33.5
13.2 7.1
8.2 4
2-ø1.8(Mounting holes for manifold)
A B
11.5 7
Depress and turn tooperate and lock override.
Manual override
BA
2-ø1.8(Mounting holes for manifold)
53.6 (GZ, GS: 54.6)
33.5
13.2 7.1
8.2 4
11.5 7
GH
64.3
49.5
15
20
13.5
(Lead wire length)
≅ 300
28
9
39.1
(Lea
d w
ire le
ngth
)
≅ 30
0
28.4
22 3.2
16.4
10
2-ø3.5
(Mounting holes)
34.8
15.7
22.3
M plug connector (M): SYJ3120-�M��-M3-Q
Other dimensions are the same as the grommet style.
∗
∗∗
1.3-12
Series SYJ3000
2 Position Double
L plug connector (L): SYJ3220-�L��-M3-Q
98.6
69
18.5
18.520
13.5
2-ø3.2 equivalent
(Mounting holes)
15.6
9
28
BA
37
7.1
71.4
1.8
8.2
4
2-ø1.8
(Mounting holes for manifold)
7
28
9
39.1
≅
300
(Lea
d w
ire le
ngth
)
BA
2-ø1.8(Mounting holes for manifold)
77.2 (GZ, GS: 79.2)
37
7.1
1.8
8.2
4
7Depress and turn tooperate and lock override.
Manual override
2-ø3.2 equivalent
(Mounting holes) 18.5
G: ≅ 300H: ≅ 600
78.8 (GZ, GS: 80.2)
6918
.5
13.520
(Lead wire length)Bracket
15.6
9
28
(Non-locking)Manual override
A B
37
7.11.8
8.2
4
2-ø1.8
(Mounting holes for manifold)
7
≅ 300
(Lead wire length)
79.4
69
18.5
18.520
13.5
2-ø3.2 equivalent(Mounting holes)
Bracket
R RP
7 7
10110.
5 5-M3(Piping port)
Grommet (G), (H): SYJ3220-� ��-M3-QGH
Other dimensions are the same as the grommet style.
M plug connector (M): SYJ3220-�M��-M3-Q
Other dimensions are the same as the grommet style.∗∗
1.3-13
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Grommet (G), (H): SYJ3 20-� ��-M3-Q
3 Position Closed Centre/Exhaust Centre/Pressure Centre
L plug connector (L): SYJ3 20-�L��-M3-Q
R RP
7 7
10110.
5 5-M3
(Piping port)
15.6
9
28
28
9
39.1
≅
300
(Lea
d w
ire le
ngth
)
345
345
15.6
9
28
(Non-locking)Manual override
BA
50.5 (GZ, GS: 51.5) 39.6 (GZ, GS: 40.6)
30.5 19.5
5.31.8
8.2
4
7Depress and turn tooperate and lock override.
Manual override2-ø1.8
(Mounting holes for manifold)
GH
2-ø3.2 eauivalent
18.5
91.7 (GZ, GS: 93.1)
40.4 (GZ, GS: 41.1)
46.5 35.5
20 18.5
13.5
Bracket
G: ≅ 300H: ≅ 600
(Lead wire length)(Mounting holes)
A B
8.2
4
7
30.5
5.3
19.5
1.8≅ 300
(Lead wire length)
2-ø1.8(Mounting holes for manifold)
111.6
50.4
18.5
18.520
13.5
Bracket
2-ø3.2 equivalent(Mounting holes)
M plug connector (M): SYJ3 20-�M��-M3-Q345
BA
30.5 19.5
84.4
36.7
8.2
4
7
1.8 5.3
2-ø1.8(Mounting holes for manifold)
92.4
40.7
18.5
18.520
13.5
Bracket2-ø3.2 equivalent
(Mounting holes)
Other dimensions are the same as the grommet style.Other dimensions are the same as the grommet style.∗ ∗
1.3-14
Series SYJ3000
2 Position Single
L plug connector (L): SYJ3140-�L��-M5-Q
R2 R1P
28.5
5
33.5
10 10
14 14
15
5-M5
(Piping port)
5
10
10 10
22.5
41.5
13
52.6
≅
300
(Lea
d w
ire le
ngth
)
29.1
22.5
13
41.5
Grommet (G), (H): SYJ3140-� ��-M5-QGH
29.1
22.5
13
41.5
(Non-locking)Manual override
A
A
B
B
17.511
2.5
54.4 (GZ, GS: 55.1)
53.6 (GZ, GS: 54.6)
33.5
22 4(Mounting holes)Depress and turn to
operate and lock override.
Manual override
G: ≅ 300H: ≅ 600
(Lead wire length)
2-ø3.2
B
B
AA
17.5112.
5
33.5
22 4
64.3≅ 300
(Mounting holes)2-ø3.2
(Lead wire length)
R2 R1P
5
33.5
10 10
14 14
15
5-M5
(Piping port)
R2 R1P
5
33.5
10 10
14 14
15
5-M5
(Piping port)
Other dimensions are the same as the grommet style. Other dimensions are the same as the grommet style.
A
A
B
B
33.5
22 4
17.511
2.5
50.7
54.7
(Mounting holes)2-ø3.2
M plug connector (M): SYJ3140-�M��-M5-Q
∗∗
1.3-15
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Grommet (G), (H): SYJ3240-� ��-M5-Q
2 Position Double
L plug connector (L): SYJ3240-�L��-M5-Q
5
10
10 9
22.5
41.5
13
52.6
(Lea
d w
ire le
ngth
)
≅ 30
0
R2 R1P
5
33.5
10 10
28
5-M5
(Piping port)
29.1
22.5
13
41.5
GH
29.1
22.5
13
41.5
(Non-locking)
Manual override
Other dimensions are the same as the grommet style. Other dimensions are the same as the grommet style.
M plug connector (M): SYJ3240-�M��-M5-Q
2-ø3.2
A
A
B
B
37
22
17.511
2.5
71.4
14
79.4
(Mounting holes)B
B
A
A
17.511
2.5
37
22
98.6
14
≅ 300
(Lead wire length)
2-ø3.2(Mounting holes)
R2 R1P
5
33.5
10 10
285-M5
(Piping port)
A
A
B
B
17.511
2.5
78.8 (GZ, GS: 80.2)
77.2 (GZ, GS: 79.2)
14
37
22Depress and turn tooperate and lock override
Manual override
G: ≅ 300H: ≅ 600
(Lead wire length)
2-ø3.2
(Mounting holes)
R2 R1P
5
33.5
10 10
285-M5
(Piping port)
∗∗
1.3-16
Series SYJ3000
Grommet (G), (H): SYJ3 40-� ��-M5-Q
3 Position Closed Centre/Exhaust Centre/Pressure Centre
L plug connector (L): SYJ3 40-�L��-M5-Q
5
10
10 9
R2 R1P
5
33.5
10 10
28
14
5-M5
(Piping port)
29.1
22.5
13
41.5
345
345
GH
R2 R1P
5
33.5
10 10
14
28 5-M5
(Piping port)
29.1
22.5
13
41.5
(Non-locking)
Manual override
M plug connector (M): SYJ3 40-�M��-M5-Q345
Other dimensions are the same as the grommet style. Other dimensions are the same as the grommet style.
AA
B
B
17.511
2.5
91.7 (GZ, GS: 93.1)
53.5 (GZ, GS: 54.5) 36.6 (GZ, GS: 37.6)
37.4 (GZ, GS: 38.1)
16.533.5
22 3Depress and turn tooperate and lock override
Manual override
G: ≅ 300H: ≅ 600
(Lead wire length)
2-ø1.8(Mounting holes)
B
B
A
A
17.511
2.5
33.5 16.5
22 3
111.6
47.4
≅ 300
(Lead wire length)
2-ø3.2(Mounting holes)
22.5
41.5
13
52.6
≅
300
(Lea
d w
ire le
ngth
)
R2 R1P
5
33.5
10 10
28
14 5-M5
(Piping port)
2-ø3.2
A
A
B
B
33.5 16.5
22 3
17.511
2.5
50.7 33.7
92.3
39.2
(Mounting holes)
∗∗
1.3-17
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Standard
Location
Direction
P, R port
A, B port
Body portedSYJ3�2�
Base mountedSYJ3�3�
Valve
Top
0.9 (49.08)
__
__
Single base style/B mount
P: 1/8R: M5
M5, C4 (ø4 One-touch fitting)
Manifold Specifications
Type
Manifold style
P(SUP)/R(EXH)style
Valve stations
A, B port specifications
Port size
Effective area(1)
mm2(Nl/min)
Base mountedSYJ3�4�
M5
M3
__
0.9 (49.08)
__
__
1.2(65.76)
__
__
__
1.5(78.52)
__
__
1.0(53.98)
1/8
Base
Side
Common SUPIndividual EXH
Note 1) Value for a single operation valve mounted on the manifold base.
How to Order Valve Manifold
Specify the part numbers for the valve(s), blank plate a'ssy and the manifold base.
Example1 pc. (Manifold base)
2 pcs. (Valve)
1 pc. (Blank plate ass'y)
1 pc. (Manifold base)
2 pcs. (Valve)
1 pc. (Blank plate ass'y)
�SS5YJ3-20-03-Q SYJ3120-5G-M3-Q SYJ3000-21-1A-Q
�SS5YJ3-S41-03-C4-Q SYJ3140-5LZ-Q SYJ3000-21-2A-Q
Use manifold specification sheet.
20 31,S31 32,S32 41,S41 46,S46
Common SUP, Common EXH
2 to 20 stations
∗
Manifold Series SYJ3000
1.3-18
Flat Cable Manifold
How to Order Valve How to Order Connector Ass’y
Multiple valve wiring is simplified through the use of the flat cable connector.
Clean appearanceWith the flat cable manifold, each valve is wired to the manifold base.A single MIL specification flat cable connects the entrie manifold to the powersource.This greaty reduces installation time.
Flat Cable Manifold Specifications/(Refer to p.1.2-28 for dimensions.)
Type
Manifold style
P(SUP)/R(EXH)style
Valve stations
Location
Direction
P, R port
A, B port
SYJ3�23
SYJ3�33
A,B portspecifications
Port size
Effective areamm2(Nl/min)
Rated voltage
Connector
Internal wiring
Single base style/B mount
Common SUP/CommonEXH
4 to 12 stationsValve
Top
Base
Side
1/8
M3
0.9 (49,08)__
M5, C4 (ø4 One-touch fitting)__
1.2 (65.76)
Socket: 26 poles MIL type with strain reliefconforms to MIL-C-83503
Both for +COM and –COM
24V DC, 12V DC
Note 1) Value for a single operation of 2 position valve mounted on manifold base.Note 2) The withstand voltage specification for the wiring unit section conforms to JIS C0704, Grade .or its equivalent.
How to Order Valve ManifoldSS5YJ3-32P-07-C4- QSYJ3133-5LOU-QSYJ3233-5LOU-Q
SYJ3000-21-4A-Q SY3000-37-28ASY3000-37-29A
1 pc. (Manifold base)
3 pcs. (Valve)
3 pcs. (Valve)
∗Use manifold specification sheet.
Type 21P
Type 32P
21P 32P
(1)
The manifold can be wired for either positive or negative common because only non-polar valves are used.The use of valves other than non polar types are not recommended and may cause damage to the electrical circuit.
Caution
SYJ3DC
12345
5 LOU
2 position single solenoid2 position double solenoid3 position closed centre3 position exhaust centre3 position pressure centre
Configuration
—DE
Non-locking push stylePush-locking slotted stylePush-loking kob style
Manual override
A/B port size
56
24V DC12V DC
Single solenoid SY3000-37-28A
SY3000-37-29ADouble solenoid3 position
Rated voltage For 12V/24V DC
Flat cable style:“U” type is for DC specification. Contact SMC for other specifications.
1 323
—M3
Base mountedM3
Single solenoid SY3000-37-46A
SY3000-37-47ADouble solenoid3 position
For 100V DC
(2)
1 pc. (Blank plate ass'y)
3 pcs. (Connector ass'y)
3 pcs. (Connector ass'y)
Protective classclass III (Mark: )
1.3-19
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
20 Type (5 Port/Body ported)
31 Type (4 Port/Base mounted)
32 Type (4 Port/Base mounted)
How to Order
Applicable blank plateassembly
Appilcable blank plateassembly
SYJ3000-21-1A-Q
SYJ3000-21-2A-Q
How to Order
SS5YJ3-- 31-- 05 --M3-Q
02
:
20
2 stations
:
20 stations
Stations
How to Order
SS5YJ3-- 32-- 05 -- M5
M5
C4
M5
ø4 One-touch fitting
A, B port side
Common SUP/Common EXH
Common SUP/Individual EXH
46 Type (5 Port/Base mounted)
Applicable blank plateassembly
How to Order
41 Type (5 Port/Base mounted)
Appicable blank plateassembly
SYJ3000-21-2A-Q
SYJ3000-21-2A-Q
How to Order
02
:
20
2 stations
:
20 stations
Stations
SS5YJ3-- 41-- 05 -- C4
SS5YJ3-- 46-- 05 -- M5
Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Single solenoid coil is located on opposite side as the A, B port.Single solenoid coil is located on same side as the A, B port.
Valve mounting direction
—
S
02
:
20
2 stations
:
20 stations
Stations
Single solenoid coil is located on opposite side as the A, B port.Single solenoid coil is located on same side as the A, B port.
Valve mounting direction
Single solenoid coil islocated on opposite side as the A, B port.Single solenoid coil is located on same side asthe A, B port.
Valve mounting direction02
:
20
2 stations
:
20 stations
Stations
M5
C4
M5
A, B port side
M5
C4
M5
A, B port side
02
:
20
2 stations
:
20 stations
Stations
31 Type S31 Type
32 Type S32 Type
41 Type S41 TypeSingle solenoid coil is located on same side as the A, B port.
46 Type S46 Type Single solenoid coil is located on same side as the A, B port.
Note) For more than 10 stations, supply air to both sides of "P" port.
A/B portM3
P portM5
R portM5
M5
A/B portM3 X 0.5
A/B portM3 P portP port
R portM5
R portM5
M5
A/B portM5, C4
A/B portM5, C4
P port1/8
P port1/8
R port1/8
R port1/8
M5
A/B portM5, C4
A/B portM5, C4P port
1/8 P port1/8
R1/R2 port
M5R1/R2 port
A/B portM5 X 0.8, C4 A/B port
M5, C4
P port1/8
P port1/8
R port1/8
R port1/8
Single solenoid coil is located on same side as the A, B port.
Single solenoid coil is located on same side as the A, B port.
Single solenoid coil is located on opposite sideas the A, B port.Single solenoid coil is located on same side as the A, B port.
Valve mounting direction
Applicable solenoid valveSYJ3�20-����-M3-QSYJ3�23-����-M3-Q
Applicable solenoid valveSYJ3�30-����-QSYJ3�33-����-Q
Applicable solenoid valveSYJ3�40-����-QSYJ3�43-����-Q
Applicable solenoid valveSYJ3�40-����-QSYJ3�43-����-Q
SS5YJ3--20-- 05
—
S
—
S
—
S
ø4 One-touch fitting
ø4 One-touch fitting
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
Protective classclass lll (Mark: )
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
1.3-20
Series SYJ3000
21P Type
32P Type
How to Order
Applicable connector assemblyRefer to the p.1.3-19.
Applicable connector assemblyRefer to the p.1.3-19.
SS5YJ3--21P-- 07
How to Order
SS5YJ3--32P-- 07 -- C4
04
:
12
4 stations
:
12 stations
Stations
Flat Cable Manifold
M5
C4
M5
ø4 One-touch fitting
A, B port side04
:
12
4 stations
:
12 stations
Stations
Common SUP/Individual EXH Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Installation of the SYJ300 Valves on the SY3000 Manifold.
The SYJ3000 series valves can be mounted on the manifold for the SYJ3000 series.
qSS5YJ3-20, SS5YJ3-21PThe 3 port valve can be used on the 4 port manifoldby simply sealing off the unused "R" port with plugSYJ3000-33-1.Applicable solenoid valveSYJ312, SYJ312MSYJ322, SYJ322M
wSS5YJ3-31, -S31, SS5YJ3-32, -S32, SS5YJ3-46, -S46, SS5YJ3-32PThe 3 port valve can be used on the 4 port manifoldwithout modification. The A port of the valve will flowout of the B port of the manifold.Applicable solenoid valveSYJ314, SYJ314MSYJ324, SYJ324M
eSS5YJ3-41, -S41The 3 port valve can be used on the 4 port manifoldby simply sealing off the unused "R" port with plugSYJ3000-33-1. The A port of the valve will flow out ofthe B port of the manifold.Applicable solenoid valveSYJ314, SYJ314MSYJ324, SYJ324M
Plug (SYJ3000-33-1)
Seal the unused "R" portat the end of the manifold.
Plug (SYJ3000-33-1)
Seal the unused "R" portat the end of the manifold.
(SYJ300 3 port valve)
(SYJ300 3 port valve)
A port of the 3 port valve flows out of the manifold B port.
SS5YJ3-41SS5YJ3-20
P port R port
A, B portM3
P port1/8 1/8
1/8 1/8
R port
A, B portM5, C4
Applicable blank plateassemblySYJ3000-21-3A-Q(With dust cap)
Applicable blank plateassembly
Applicable valveRefer to the p.1.3.-19.
Applicable valveRefer to the p.1.3-19.
SYJ3000-21-3A-Q(With dust cap)
-Q
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
1.3-21
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Combination of Blank Plate Ass'y and Manifold Base
Combination of Solenoid Valve, Manifold Gasket and Manifold Base
4 port base mounted(SYJ3�3 )
Applicable manifold baseSS5YJ3-20SS5YJ3-21P
5 port body ported(SYJ3�2 )
5 port base mounted(SYJ3�4 )
Blank plate ass'ySYJ3000-21-1A-Q
Blank plate ass'ySYJ3000-21-2A-Q
Blank plateSYJ3000-21-1
SYJ3000-14-7
Phillips head screwSY100-33 -2(M1.7 X 7, mattednickel plated)
Configuration ofsurface is different.
Steel ball is driven in.
SYJ3000-21-1-Q
SYJ3000-14-2
Applicable manifold baseSS5YJ3-31SS5YJ3-S31SS5YJ3-32SS5YJ3-S32SS5YJ3-32P
Applicable manifold baseSS5YJ3-41SS5YJ3-S41SS5YJ3-46SS5YJ3-S46
Applicable manifold baseSS5YJ3-20
Applicable manifold base(sub-plate)SS5YJ3-41SS5YJ3-S41SS5YJ3-46SS5YJ3-S46SS5YJ3-31SS5YJ3-S31SS5YJ3-32SS5YJ3-S32
SS5YJ3-31-S31-32-S32
Blank plate ass'ySYJ3000-21-4A-Q
Blank plate ass'ySYJ3000-21-3A-Q
Applicable manifold base
SS5YJ3-32PApplicable manifold base
SS5YJ3-21P
Phillips head screwSY100-33 -2(M1.7 X 7, mattednickel plated)
Blank plateSYJ3000-21-1-Q
Phillips head screwSY100-33 -2(M1.7 X 7, mattednickel plated)
Blank plate
Manifold gasket
A Mark
SYJ3000-14-7 SYJ300014-6 SYJ3000-14-2
Phillips head screwSY100-33-3(M1.7 X 17, matted nickel plated)
A Mark A Mark
Manifold gasket Manifold gasket
A Mark A Mark
SYJ3000-14-7
Dust cap
A MarkA Mark
SYJ3000-14-6
SYJ3000-21-1-Q
SYJ3000-42-1
Difference between SYJ3�3 and SYJ3�4
SYJ3�30, 3�33 (4 port)
SYJ3�40, 3�43 (5 port)
Blank plate
Note) Manifold gasket "VJ3000-14-2" canbe used with the following manifold bases.
03
03
03
03
03
Manifold gasket Manifold gasket
Manifold gasketManifold gasket
1.3-22
Series SYJ3000
20 Type Manifold: Top Ported/SS5YJ3-20- Station -Q
Grommet (G), (H)
L plug connector (L) M plug connector (M)
235.528.5
34639
456.549.5
56760
677.570.5
78881
898.591.5
9109102
10119.5112.5
11130123
12140.5133.5
13151144
14161.5154.5
15172165
16182.5175.5
17193186
18203.5196.5
19214207
20224.5217.5
StationsL1
L2
1110 14
5
G: ≅
300
H: ≅
600
(: L
ead
wire
leng
th)
6-M5
(P, R port)
≅ 30
0
(Lea
d w
ire le
ngth
)
111.
6
98.6
1
62.8
92.3
79.4
1
53.2
53.1
42
≅ 300
(Lead wire length)
42 [4
8.5]
29.6
23
13.5
(Non-locking)Manual override
Other dimensions are the same as the grommet style.Other dimensions are the same as the grommet style.∗ ∗
RP
R R
PRA
B
A
B
A
B
A
B
A
B
2-ø3.5
(Mounting holes)
2n-M3
(A, B port)
78.8
(G
Z, G
S: 8
0.2)
52.9
(GZ,
GS:
53.
6)
322919.5
1.5
710
91.7
(G
Z, G
S: 9
3.1)
53.9
(GZ,
GS:
54.
6)
17
335
4
(Pitch)P=10.5
9
L2 3.5
L1
Depress and turn tooperate and lock override
Manual override
1.3-23
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
235.528.5
34639
456.549.5
56760
677.570.5
78881
898.591.5
9109102
10119.5112.5
11130123
12140.5133.5
13151144
14161.5154.5
15172165
16182.5175.5
17193186
18203.5196.5
19214207
20224.5217.5
Grommet (G), (H)
StationsL1
L2
S31 Type/Side Ported
L plug connector (L) M plug connector (M) SS5YJ3-S31- Station -M3-Q
127.
5
25
7.5
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
4-M5
(P, R port)
≅ 30
0
(Lea
d w
ire le
ngth
)98
.6
111.
6
1
61.3
92.3
79.4
1
51.7
31.1
54.6 ≅ 300
(Lead wire length)
B B
A A15 12
3
2n-M3
(A, B port)(Pitch)P=10.5
14.5
1
31 Type Manifold: Side Ported/SS5YJ3-31- Station -M3 -Q
A A
BB
43.5
31.1
24.5
15 12
3
2n-M3
(A, B port)(Pitch)P=10.5
11.5
1
(Non-locking)Manual override
Single solenoid coil is located on same side as the A, B port.
R
P P
R
A
B
A
B
A
B
A
B
A
B
2-ø3.5
78.8
(G
Z, G
S: 8
0.2)
51.4
(GZ,
GS:
52.
1)
30.5
13.5
3
91.7
(G
Z, G
S: 9
3.1)
52.4
(GZ,
GS:
53.
1)
18.5
31.5
6.5
(Pitch)P=10.5
9
L2 3.5
L1Depress and turn tooperate and lock override.
Manual override
(Mounting holes)
Other dimensions are the same as the grommet style.
Other dimensions are the same as the grommet style.
Other dimensions are the same as style 31.
R
P P
R
B
A
B
A
B
A
B
A
B
A
2-ø3.5
78.8
(G
Z, G
S: 8
0.2)
51.4
(GZ,
GS:
52.1)
30.513
.53
91.7
(G
Z, G
S: 9
3.1)
52.4
(GZ,
GS:
53.
1)18
.5
31.5
6.5
(Pitch)P = 10.5
9
L2 3.5
L1
(Mounting holes)
∗∗∗
1.3-24
Series SYJ3000
242.533.5
35344
463.554.5
57465
684.575.5
79586
8105.596.5
9116107
10126.5117.5
11137128
12147.5138.5
13158149
14168.5159.5
15179170
16189.5180.5
17200191
18210.5201.5
19221212
20231.5222.5
32 Type Manifold: Side Ported/SS5YJ3-32- Station -M5, C4�-Q
Grommet (G), (H) C4(Built-in One-touch fitting)
StationsL1
L2
L plug connector (L) M plug connector (M) SS5YJ3-S32- Station -M5, C4�-Q
241.533.5
35244
462.554.5
57365
683.575.5
79486
8104.596.5
9115107
10125.5117.5
11136128
12146.5138.5
13157149
14167.5159.5
15178170
16188.5180.5
17199191
18209.5201.5
19220212
20230.5222.5
StationsL1
L2
SS5YJ3-32, S32- Station -C4
SS5YJ3-32, S32- Station -M5
A A
BB
1017
7.5
31.5
10
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
4-1/8
(P,R port)
58.4
(GZ,
GS:
59.
1)
36.5
12.5
17
MA
X.591
.7 (
GZ
, GS
: 93.
1)
78.8
(GZ,
GS
: 80.
2)
1
20155
2n-One-touch fittiing
(A, B port)(Pitch)P=10.5
16
1.5
L2
124.5
L1
Applicable tube: T0425
98.6
111.
6
1
63.3
92.3
79.4
1
53.7
36.159.6 ≅ 300
(Lead wire length)
BA
BA20 15 5
2n-M5(A, B port)
(Pitch)P=10.5 17.5
1
A A
BB
48.5
[55]
36.1
29.5
20 15
5
(With light and surge voltage suppressor)
2n-M5
(A, B port)(Pitch)P=10.5
14.5
1
(Non-locking)Manual override
≅ 30
0
(Lea
d w
ire le
ngth
)
BA
BA
L211
4.5L1
2n-One-touch fittiing
(A,B port)Applicable tube: T0425
(Pitch)P=10.5 18
1.5
C4 (Built in One-touch fitting)
S32 Type/Side Ported Single solenoid coil is located on same side as the A, B port.
RP
PR
A
B
A
B
A
B
A
B
A
B
2-ø4.5
78.8
(G
Z, G
S: 8
0.2)
53.4
(GZ,
GS:
54.
1)
32.5
161
91.7
(G
Z, G
S: 9
3.1)
54.4
(GZ,
GS:
55.
1)
16.5
33.5
4.5
(Pitch)P=10.5 11.5
L2 4
L1Depress and turn tooperate and lock override
Manual override
(Mounting holes)
Other dimensions are the same as the grommet style.
Other dimensions are the same as the grommet style.
Other dimensions are the same as the type 32.
Other dimensions are the same as the M5.
R
P P
R
B
A
B
A
B
A
B
A
B
A
2-ø4.5
78.8
(GZ,
GS:
80.
2)
56.4
(GZ,
GS: 5
7.1)
35.515
.51.
5
91.7
(GZ
,GS
:93.
1)
57.4(
GZ,G
S:58
.1)
36.5
13.5
(Pitch)P=10.5
11.5
L2 4L1
(Mounting holes)
∗
∗∗∗
�-Q
�-Q
1.3-25
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
239.531.5
35042
460.552.5
57163
681.573.5
79284
8102.594.5
9113105
10123.5115.5
11134126
12144.5136.5
13155147
14165.5157.5
15176168
16186.5178.5
17197189
18207.5199.5
19218210
20228.5220.5
41 Type Manifold: Side Ported/SS5YJ3-41- Station -M5, C4
Grommet (G), (H) C4 (Built-in One-touch fitting)
StationsL1
L2
L plug connector (L) M plug connector (M)
A A
BB
10
36.5
MA
X.5
21.5
20 15 5
2n-One-touch fitting
(A, B port)
(Pitch)P=10.5 12
2
Applicable tube: T0425
≅ 30
0
(Lea
d w
ire le
ngth
)98
.6
111.
6
1
70.8
92.3
79.4
1
61.2
36.159.6 ≅ 300
(Lead wire length)
BA
BA
B
A
B
A
20 15 5
2n-M5
(A, B port)
(Pitch)P=10.5 15
2
20 15 5
2n-One-touch fitting
(A, B port)
(Pitch)P=10.5 15
2
applicable tube: T0425
A A
BB
48.5
36.1
29.5
20 15 5
2n-M5(A, B port)
(Pitch)P=10.5 12
2
(Non-locking)Manual override
C4 (Built-in one-touch fitting)
S41 Type/Side Ported Single solenoid coil is located on same side as the A, B port.
SS5YJ3-S41- Station -M5, C4
RR
P
A
B
A
B
A
B
A
B
A
B
2-ø4.5
21.5 36
.5
10
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
1/8(P port)
78.8
(G
Z, G
S: 8
0.2)
60.9
(GZ,
GS:
61.
6)
403
18
10
21/8(P port)
11.5
91.7
(G
Z, G
S: 9
3.1)
61.9
(GZ,
GS:
62.
6)
39
41
(Pitch)P=10.5 9
L2 4
L1Depress and turn tooperate and lock overrride.
Manual override
(Mounting holes)
Other dimensions are the same as the M5.
Other dimensions are the same as type 41.Other dimensions are the same as the grommet style.
Other dimensions are the same as the grommet style.
P RR
B
A
B
A
B
A
B
A
B
A
2-ø4.5
78.8
(GZ,
GS
: 80.
2)
54.4
(GZ,
GS: 5
5.1)
33.5
3.5
91.7
(G
Z, G
S: 9
3.1)
55.4
(GZ,
GS: 5
6.1)
33.5
34.5
15.5
(Pitch)P=10.5 12
L2 4
L1
(Mounting holes)
∗
∗∗∗
�-Q
�-Q
1.3-26
Series SYJ3000
239.531.5
35042
460.552.5
57163
681.573.5
79284
8102.594.5
9113105
10123.5115.5
11134126
12144.5136.5
13155147
14165.5157.5
15176168
16186.5178.5
17197189
18207.5199.5
19218210
20228.5220.5
46 Type Manifold: Side Ported/SS5YJ3-46- Station -M5, C4
Grommet (G), (H) C4 (Built-in One-touch fitting)
StationsL1
L2
L plug connector (L) M plug connector (M) SS5YJ3-S46- Station -M5, C4
A A
BB
10
2-1/8(P port)
35
19
MA
X.5
20155
2n-One-touch fitting(A, B port)
(Pitch)P=10.5 15.5
1.5
Applicable tube: T0425
≅ 30
0
(Lea
d w
ire le
ngth
)98
.6
111.
6
1
69.8
92.3
79.4
1
60.2
36.159.6 ≅ 300
(Lead wire length)
S46 Type/Side Ported Single solenoid coil is located on same side as the A, B port.
A A
BB48
.5
36.1
29.5
2015
5
2n-M5
(A, B port)(Pitch)P=10.5
15.7
1.5
19
35
10
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
2-1/8(P port)
BA
BA 20155
2n-M5(A, B port)
(Pitch)P=10.5 15.7
1.5
BA
BA 2015
5
2n-One-touch fitting(A, B port)Applicable tube: T0425
(Pitch)P=10.5 15.7
1.5
P
P
A
B
A
B
A
B
A
B
A
B
2-ø4.5
78.8
(G
Z, G
S: 8
0.2)
59.9
(GZ,
GS:
60.
6)
39
2
91.7
(G
Z, G
S: 9
3.1)
60.9
(GZ,
GS:
61.
6)
40
1010
(Pitch)P=10.5 10.5
L2 4
L1
Depress and turn tooperature and lock override.
Manual override
(Mounting holes)
Other dimensions are the same as the M5.
Other dimensions are the same as type 46.Other dimensions are the same as the grommet style.
Other dimensions are the same as the grommet style.
P
P
B
A
B
A
B
A
B
A
B
A
2-ø4.5
78.8
(GZ,
GS:
80.
2)
53.9
(GZ,
GS: 5
4.6)
4
330.
5
91.7
(G
Z, G
S: 9
3.1)
54.9
(GZ,
GS: 5
5.6)
2516
34
(Pitch)P=10.5 10.5
L2 4
L1
(Mounting holes)
∗
∗ ∗ ∗
�-Q
�-Q
1.3-27
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ3000
Flat Cable Manifold
SS5YJ3-21P- Station
C4(Built-in One-touch fitting)
20
48.5
265.8
28.5
Triangle mark
Connector polarity indicationApplicable connector: 26-pole MIL type(Conforms to MIL-C-83503)
177.
5
31.5
10
4-1/8(P, R port)
A
B
A
B
29.5 15
5
(Pitch)P=12.5 19.5
1
2n-One-touch fitting
(A, B port)
Applicable tube:T0425
1712
.5
36.5
MA
X.5
10
4-1/8(P, R port)
29.5
(Non-locking)Manual override
(Non-locking)
Manual override
A
B
A
B
29.8 15
5
(Pitch)P=12.5 19.5
1
2n-M5
(A, B port)
(Non-locking)
Manual override
PR
RP
B
A
B
A
B
A
B
A
B
A
B
A
62.3
49.3
31.5
18.5
166.
5
15.5
8.5
45.5
37.3
(Pitch)P=12.5 14.5
22
L2 4L1
61.3
3
65.4
2-ø4.5
2n-M3
(A, B port)Depress and turn tooperate and lock override.
Manual override
(Mounting holes)
P
R
RP
B
A
B
A
B
A
B
A
B
A
B
A
(Pitch)P=12.5 14.5
L2 4L1
63.3
1
65.4
64.3
47.3
33.5
16.5
164.
5
45.5
35.3
Depress and turn tooperate and lock override.
Manual override
2-ø4.5(Mounting holes)
Triangle mark
20
48.5
265.8
28.5Connector polarity indicationApplicable connector: 26-pole MIL type(Conforms to MIL-C-83503)
177.
5
31.5
10
4-1/8(P, R port)
�-Q
SS5YJ3-32P-��-M5, C4�-Q
StationsL1
L2
472.564.5
58577
697.589.5
7110102
8122.5114.5
StationsL1
L2
9135127
10147.5139.5
11160152
12172.5164.5
1.3-28
Series SYJ3000
1.3-29
( )
Series SYJ5000
5 Port Solenoid ValveRubber Seal
Model
3.6 (196.30)3.6 (196.30)3.2 (176.67)
3.6 (196.3) [2.7 (147.23)]P A,B: 4.0(215.93)
[2.7 (147.23)]A, B R1, R2: 3.4 (186.49)
3 (166.86)3 (166.86)3 (166.86)
3 (166.86) [2.4 (127.60)]P A, B: 3.5(186.49)
[2.9 (157.04)]A, B R1, R2: 3.1(166.86)
3.5 (186.49)3.5 (186.49)3.2(176.67)
3.2 (176.67) [2.4 (127.60)]P A, B: 3.8 (206.12)
[3.0 (166.86)]A, B R1, R2: 3.2 (176.67)
4.5 (245.38)4.5 (245.38)3.4 (186.49)
4.5 (245.38) [2.7 (147.23)]P A, B: 5.3 (245.38)
[3.1 (166.86)]A, B R1, R2: 4.0 (215.93)
Grommet
4358
69
5065
76
5065
76
77 (43)92 (58)
103 (69)
L/Mplug connector
4562
73
5269
80
5269
80
79 (45)96 (62)
107 (73)
2 position
3 position
2 position
3 position
2 position
3 position
2 position
3 position
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
M5
A, B port : C4 ø4 One-touch
fittingP, R port
: M5
A, B port : C6
ø6 One-touch fitting
P, R port : M5
1/8
( )
Note 1) [ ] for normal position. Exhaust centre: A, B R1 ,R2 Pressure centre: P A, BNote 2) ( ): Without sub-plate.
Air0.15 to 0.70.1 to 0.70.15 to 0.7
Max. 50≤ 25≤ 40
53
Non-locking push, Push-turn-locking slotted styleIndividual pilot exhaust, Common exhaust (pilot and main valve)
Not requiredFree
150/30Dust proof
SYJ5�20- -M5-Q
SYJ5�20- -C4-Q
SYJ5�20- -C6-Q
SYJ5�40- -01- -Q
(B)2
1(P)
1(P)
5(R1)
3(R2)
3(R)
1(P)
3(R)
1(P)
3(R)
1(P)
3(R)
1(P)
3(R)
(A)4
(B)2
1(P)
5(R1)
3(R2)
1(P)
5(R1)
3(R2)
1(P)
5(R1)
3(R2)
1(P)
5(R1)
3(R2)
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
(B)2
(A)4
JIS Symbol
2 position double
2 position single
3 position closed centre
3 position exhaust centre
3 position pressure centre
Body ported
2 position double
2 position single
3 position closed centre
3 position exhaust centre
3 position pressure centre
Base mounted (with sub-plate)
Body ported
Base mounted
Configruration Effective areamm2 (Nl/min)
Weight (g)Valve model
Fluid
Specifications
Operating pressure range(MPa)
Ambient and fluid temperature °C
Response time (ms) at 0.5MPa
Max. operating frequency (Hz)
Manual overridePilot exhaustLubricationMounting positionImpact/Vibration resistance (m/s2)Protection structure
(4)
2 position single2 position double
3 position
2 position single,double3 position
2 position single,double3 posittion
Note 4) According to dynamic performance test JIS B8375-1981 (Coil temperature 20°C, at rated voltage, without surge voltage suppressor)Note 5) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test
was performed on the axis and right angle direction of the main valve and armature, for both energized andde-energized states. (Value in the initial stage)
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000Hz. Test was performedat both energized and de-energized states to axis and right angle direction of the main valve and armature. (Value in the initial stage)
P.1.3-72OrderMade
(1) (2)
Bo
dy
po
rted
Bas
e m
ou
nte
d
Port size
(5)
Solenoid Specifications
Note 6) At rated voltages
Grommet (G)/(H), L plug connector (L), M plug connector (M)24, 12, 6, 5, 3
±10% rated voltage0.5 (With light: 0.55)
Electric entryCoil rated voltage (V)Allowable voltagePower consumpution (W)Surge voltage suppressor
Indicator light
DC
DC
(6)
DiodeLED
1.3-30
Cylinder Maximum Operating Speed
700
600
500
400
300
200
100
20
Max
.ope
ratin
g sp
eed
(m
m/s
)
CM2 cylinder CA1 cylinderCylinder bore size (mm)
�System Figure
Operating conditions: Pressure 0.5MPa, Load rate 50%At cylinder extended, cylinder stroke CM2: 300mm
CA1: 500mm
System components
System Solenoid valve
SYJ5�40-01Rc(PT)1/8
(S = 4.5mm2)
AS2301F01-04
AS2301F01-06
AS3301F -06
AS3301F -08
Silencer
AN110-01(S = 35mm2)
Fitting(Tube O.D. X Port size)
ø4 X 1/8
ø6 X 1/8
ø8 X 1/8
Solenoid valve
Fitting
Speed controller
Built-in Speed Controller Style
SYJ5�5�� Built-in exhaust flow controls enable simple cylinder speed adjustments.� When mounted on the manifold, the common exhaust discharges the pilot and main valve exhaust through a common exhaust port to enable simple exhausting.
JIS Symbol
(Single)
How to order valve with built-in speed controller
SYJ5� 5�--�� � �--�
Config.
800
25 32 40 40 50 63 80 100
Body option
Rated voltage
Electrical entryLight and surge voltage suppressor
Manual override
Port size
Flow control specifications( �R)
2
1
Effe
ctiv
e ar
ea (
mm
2 )
1
0 2 3 4 5 6 7(Fully open)(Fully closed)
Note)
0203
0203
B A
R P
Piping length1m
Piping length5m
AB
Plate fixing screw
C
B
A D
C
Note) Do not loosen plate fixing screw.
Air
cylin
der
Speed controller
Silencer
A
B
C
D
�When using SYJ5�53 model the speed controller must be opened more than 1 complete rotation from fully closed in order to function properly.
�Adjust the speed controller with a torque of 0.3Nm or less.
-Q
1.3-31
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
How to Order
SYJ5 2
SYJ5 4
12345
2 position single solenoid2 position double solenoid3 position closed centre3 position exhaust centre3 position pressure centre
Configuration
(For manifold type 20)
—SZU
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
Light and surge voltage suppressor
Note)
Manual override—: Non-loking push style
D: Push-turn-locking slotted style
Bracket
—: Without bracket
56VSR
24V DC12V DC6V DC5V DC3V DC
Rated voltageFor DC
Port size—: Without sub-plate
01: With 1/8 sub-plate
Body option
(With gasket and screws)
R port P, E port
M5C4C6
M5 ø4 One-touch fittingø6 One-touch fitting
A, B port size
F : With bracket
0: Individual exhaust for the pilot valve
3: Common exhaust for the pilot and main valves
R port P, E port
Base mounted
Body ported 5 L
L
1
2 5
0
0
M5
For sub-plate,manifold type40, 41, 42, 43
G: 300mm lead wire
L: 300mm lead wire
M: 300mm lead wire
MN: Without lead wire
H: 600mm lead wire
LN: Without lead wire
LO: Without connector
MO: Without connector
∗LN and MN types are with 2 pcs. of socket.
Electrical entry24V, 12V, 6V, 5V, 3V DC
Grommet L plug connector M plug connector
For electrical entry G,H,L and M
· The double solenoid mounting bracket is supplied unattached.
9 (Less than 50VDC)
-Q
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
Protective classclass III (Mark: )
Contact SMC for other voltages (9)OrderMade
1.3-32
Series SYJ5000
SY114
56VSR
Construction
Component Parts Replacement PartsNo.q
w
e
r
t
y
BodyPiston plateEnd coverPistonSpool ass´ySpool spring
MaterialAluminum die cast
ResinResinReain–––SUS
NoteWhiteWhiteWhite–––––––––
No.��
NoteAluminum die cast
Part No.SYJ5000-22-1-QSY114-���-Q
How to Order Pilot Valve Assembly How to Order Connector Assembly
5 G
24V DC12V DC6V DC5V DC3V DC
Voltage
DC : SY100-30-4A-
––6101520253050
300mm600mm1000mm1500mm2000mm2500mm3000mm5000mm
Lead wire length
R1 P R2 R1 P R2
R1 P R2
A BA B
A B
2 position single 2 position double
3 position closed centre/exhaust centre/pressure centre3 position closed centre
3 position exhaust centre
3 position pressure centre
(This construction shows a closed centre)
Description DescriptionSub-platePilot valve
GHL
LNLOM
MNMO
Electrical entryGrommet (Lead wire length: 300mm)Grommet (Lead wire length: 600mm)
With lead wireWithout lead wireWithout connectorWith lead wireWithout lead wireWithout connector
L plugconnector
M plug connector
A
R1 R2P
B A
R1 R2P
B
A
R1 R2P
B
A
R1 R2P
B
A
R1 R2P
B
e y t r w w
w
q
q
t
t
r
r
i
i
u
i
q
-Q
—SZU
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
Light and surge voltage suppressorFor electrical entry G,H,L and M
1.3-33
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Grommet (G), (H): SYJ5120-� ��-M5-Q
L plug connector (L): SYJ5120-�L��-M 5-Q M plug connector (M): SYJ5120-�M��-M 5-Q
With bracket
∗ Other dimensions are the same as the grommet style.
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
Built-in One-touch fitting:SYJ5120-� ��-G
HC4C6
65.4
(GZ,
GS:
66.
1)
2.3
29.5[36]
2-ø3.5(Mounting holes)
37
30
18 25
3.5
10.6
A B
2-One-touch fitting(A, B port)Apricable tube C4: T0425 C6: T0604
C4:
(3)
C6:
(3.
2)32
.3
26.6
20
11 2-ø2.6
(Mounting holes)19.558.2
73
3
29.5
17.1
10.5
10
15
16
23
26.6
20
11
19.5
58.2
3
2-ø2.6(Mounting holes)
10
15
16
40.6
[47.
1]
10.5
≅
300
(Lea
d w
ire le
ngth
)
23
2 Position SingleGH
(Non-locking)Manual override
29.5
23
10
15
16
10.5
17.1 26
.6
20
3.5 4 11
19.5
58.2
62.3 (GZ, GS: 63.3)
2-ø2.6(Mounting holes)
3
215-M5
(Piping port)
R2
R1 P
18
10.62-M3
(Mounting screw)
Manual override
Depress and turn tooperate and lock override.
BA
63.1 (GZ: 63.8) G: ≅ 300H: ≅ 600
(Lead wire length)42.2
10
192-ø2.6(Mounting holes for mainfold)
11 5
63.459.4
42.2
10
19 2-ø2.6(Mounting holes for manifold)
11 5 A B
42.2 ≅ 300(Lead wire length)
511
10
19 2-ø2.6(Mounting holes for manifold)
A B
-Q
1.3-34
Series SYJ5000
Grommet (G), (H): SYJ5220-� ��-M 5-Q
L pulg connector (L): SYJ5220- �L��-M 5-Q M plug connector (M): SYJ5220-�M��-M 5-Q
2 Position Double
Built-in One-touch fitting:SYJ5220-� ��-
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
GH
C4C6
3.5
A B
10.6
2-One-touch fitting(A, B port)Applicable tube C4: T0425 C6: T0604
C4:
(3)
C6:
(3.
2)32
.3
215-M5
(Pipng port)
R1 P
R2
29.5
17.1
10.5
10
15
23
23
40.6
10.5
≅ 30
0
(Lea
d w
ire le
ngth
)
10
15
GH
77.4
85.6 (GZ, GS: 87.6)
2-ø2.6(Mounting holes)
11
3
26.6
2-ø2.6
(Mounting holes)
26.6
77.4
11
3
2-ø2.6(Mounting holes)
11
77.4
3
26.6
29.5
23
10
15
10.5
17.1
(Non-locking)Manual override
45.4
≅ 300
(Lead wire length)
5
11
10
19
2-ø2.6(Mounting holes for manifold)
107
A B87.8
79.8
45.4
10
19
2-ø2.6 (Mounting holes for manifold)
5
11
A B
87.2 (GZ, GS: 88.6) G: ≅ 300H: ≅ 600
(Lead wire length)45.4
10
19 2-ø2.6(Mounting holes for manifold)
A B
5
11
Depress and turn tooperate and lock override.
Manual override
-Q
1.3-35
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Grommet (G), (H): SYJ5 20-� ��-M 5-Q
3 Position Closed Centre/Exhaust Centre/Pressure Centre
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
L plug connector (L): SYJ5 20- �L��-M 5-Q M plug connector (M): SYJ5 20- �M��-M5-Q
345
GH
10.6
B
3.5
A
C4:
(3)
C6:
(3.
2)32
.3
2-One-touch fitting(A, B port)Applicable tube C4: T0425 C6: T0604
93.4
103.2 (GZ, GS: 104.6)
2-ø2.6(Mounting holes)
11
3
26.6
39.3
20
29.5
Manual override(Non-locking)
23
10
15
10.5
17.1
215-M5
(Piping port)
R1 P
R2
29.5
17.1
10.5
10
15
23
2-ø2.6(Mounting holes)
11
93.4
3
26.6
20
39.3
123
(54.1)
10
15
23
40.6
10.5
≅ 30
0
(Lea
d w
ire le
ngth
)
11
93.4
3
2-ø2.6
(Mounting holes)
26.6
20
39.3
Built-in One-touch fitting:SYJ5 20-� ��-
345
GH
C4C6
345
345
(Lead wire length)
58.2 (GZ, GS: 59.2) 43.4 (GZ, GS: 44.4)
44.2 (GZ, GS: 44.9)
38.1
10
19 2-ø2.6(Mounting holes for manifold)
Manual overrideDepress and turn tooperate and lock override.
A B
511
23.3
G: ≅ 300H: ≅ 600
5
10
19
11
38.1 23.3
2-ø2.6(Mounting holes for manifold)
54.1 ≅ 300
(Lead wire length)
A B
103.8
44.5
55.3 40.5
38.1 23.3
10
19
2-ø2.6(Mounting holes for manifold)
511
A B
-Q
1.3-36
Series SYJ5000
Grommet (G), (H): SYJ5140-� ��-01
L plug connector (L): SYJ5140-�L��-01�-Q M plug connector (M): SYJ5140-�M��-01�-Q
2 Position Single
Built-in speed controllerSYJ5150-� ��-01�-Q
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
GH
GH
19.4 10.3
MA
X.1
3.5
5.5
32
10
15
16
24
Manual override
51.5
45
39.1
32.5
21.5
17 11.5
8.5
32
10
15
24
51.5
45
39.1
32.5
21.5
24(M
ount
ing
hole
s pi
tch)
37.5 (Mounting holes pitch)
42.7
4
73.5≅ 300
(Lead wire length)
2-ø4.3(Mounting holes)
A
B
AB
R P 24(M
ount
ing
hole
s pi
tch)
37.5(Mounting holes pitch)
42.7
4
63.9
2-ø4.3(Mounting holes)
A
B
AB
R P
59.9
32
10
15
24
62.6
45
32.5
21.5
≅ 30
0
(Lea
d w
ire le
ngth
)
6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port)
6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port) 6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port)
24(M
ount
ing
hole
s pi
tch)
37.5(Mounting holes pitch)
42.7
4
63.6 (GZ, GS: 64.3)
62.8 (GZ, GS: 63.8) G: ≅ 300H: ≅ 600
(Lead wire length)
2-ø4.3(Mounting holes)
A
B
AB
R P
Depress and turn tooperate and lock override.
Manual override
�-Q
1.3-37
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Grommet (G), (H): SYJ5240-� ��-01� -Q
L plug connector (L): SYJ5240-�L��-01� -Q M plug connector (M): SYJ5240-�M��-01� -Q
2 Position Double
Built-in speed controllerSYJ5250-� ��-01
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
19.4 10.3
MA
X.1
3.5
5.5
24(M
ount
ing
hole
s pi
tch)
37.5(Mounting holes pitch)
42.7 19.9
4
87.8
23.9
A
B
AB
R P
59.9
2-ø4.3(Mounting holes)
2.7
32
10
15
24
62.6
32.5
21.5
45≅
300
(Lea
d w
ire le
ngth
)
32
10
15
24
51.5
45
39.1
32.5
21.5
24(M
ount
ing
hole
s pi
tch)
37.5(Mounting holes pitch)
42.7
4
107≅ 300
(Lead wire length)
2-ø4.3(Mounting holes)
A
B
AB
R P
2.7
33.5
GH
GH
6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port) 6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port)
Depress and turn tooperate and lock override.
Manual override
24(M
ount
ing
hole
s pi
tch)
37.5(Mounting holes pitch)
42.7
4
87.2 (GZ, GS: 88.6)
85.6 (GZ, GS: 87.6)
22.8 (GZ, GS: 23.8)
23.6 (GZ, GS: 24.3)
G: ≅ 300H: ≅ 600
2-ø4.3(Mounting holes)
A
B
AB
R P
2.7
(Lead wire length)
32
10
15
24
51.5
45
39.1
32.5
21.5
(Non-locking)Manual override
17 11.5
8.5
6 6
48.6
8.5
17 17
45.5
4-1/8(Piping port)
�-Q
1.3-38
Series SYJ5000
Grommet (G), (H): SYJ5 40-� ��-01� -Q
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
L plug connector (L): SYJ5 40-�L��-01� -Q M plug connector (M): SYJ5 40-�M��-01� -Q
19.4 10.3
MA
X.1
3.5
5.5
Depress and turn tooperate and lock override.
Manual override
G: ≅ 300H: ≅ 600
(Lead wire length)
37.5(Mounting holes pitch)
43.3
4
103.2 (GZ, GS: 104.6) 101.6 (GZ, GS: 103.6)
38.2 (GZ, GS: 39.2)
39 (GZ, GS: 39.7) 2-ø4.3(Mounting holes)
A
B
AB
R P
18.1
24(M
ount
ing
hole
s pi
tch)
4-1/8(Piping port)
6 6
8.5
17 17
45.5
51.5
15
10
2432
4539
.1
32.5
21.5
≅ 30
0
(Lea
d w
ire le
ngth
)
32
10
15
24
32.5
21.5
4562
.6
345
GH Built-in speed controller
SYJ5 50-� ��-01� -Q345
GH
345
345
3 Position Closed Center/Exhaust Center/Pressure Center
8.517 11.5
4-1/8(Piping port)
6 6
8.5
17 17
45.5
24
(Mou
ntin
g ho
les
pitc
h)
B
18.1
37.5(Mounting holes pitch)
43.3
4
60.5 35.339.3
103.8
A
B
A
R P
2-ø4.3(Mounting holes)
51.5
32
15
24
10
39.1
32.5
21.5
Manual override
(Non-locking)
24(M
ount
ing
hole
s pi
tch)
A
B
AB
R P
2-ø4.3(Mounting holes)
37.5(Mounting holes pitch)
43.3
4
≅ 300
(Lead wire length)
123
48.9
18.1
4-1/8(Piping port)
6 6
8.5
17 17
45.5
1.3-39
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Manifold Series SYJ5000
Standard
Body portedSYJ5�2�
Base mountedSYJ5�4�
Valve
Top
M5: 3.4 (186.49)C4: 3 (166.86) C6: 3.4 (186.49)
Single base style/B mount
Common SUP, Common EXH
2 to 20 stations
1/8
C4 (ø4 One-touch fitting)
Manifold Specifications
M5C4C6
M5 X 0.8
__ __ __ __
1/8
Base
Side
Note 1) Value for a solenoid 2 position valve mounted on the manifold base.
How to Order Valve ManifoldSpecify the part numbers for the valve(s), blank plate ass'y, and manifold base.
Example �SS5YJ5-20-03-Q ················ 1 pc. (Manifold base)
SYJ5120-5G-M5-Q ············ 2 pcs. (Valve)
SYJ5000-21-1A-Q ············· 1 pc. (Blank plate ass'y)
�SS5YJ5-43-03-C4-Q ········· 1 pc. (Manifold base)
SYJ5140-5LZ-Q ·················· 1 pc. (Valve)
SYJ5240-5LZ-Q ·················· 1 pc. (Valve)
SYJ5000-21-1A-Q ·············· 1 pc. (Blank plate ass'y)
∗ Use manifold specification sheet.
20 40 41 42 43
Base
Bottom
1/41/8, C6
(ø6 One-touchfitting)
__ 3.0 (166.86) 2.9 (157.04) 3.8 (206.12) 3.2 (176.67)
Type
Manifold style
P (SUP), R (EXH) style
Valve stations
A, B port specifications
Port size
Valve effective areamm2(Nl/min) (1)
Location
Direction
P, R port
A, B port
1.3-40
Flat Cable Manifold
�Multiple valve wiring is simplified through the use of the flat cable connector.
�Clean appearance With the flat cable manifold, each valve is wired to the manifold base. A single MIL specification flat cable connects the entire manifold to the power source. This greatly reduces installation time.
Flat Cable Manifold Specifications
Location
Direction
P, R port
Rated voltage
Connector (2)
Internal wiring
Single base style/B mount
Common SUP, Common EXH
3 to 12 stations
Valve
Top
1/8
Base
Side
1/8
M5: 3.4 (186.49)C4: 3 (166.86)C6: 3.4 (186.49)
C4 (ø4 One-touch fitting)
Socket: 26 poles MIL type with strain reliefconforms to MIL-C-83503
Both for +COM and –COM
24V DC, 12V DCNote 1) Value fo single operation of 2 position valve mounted on manifold base.Note 2) The withstand voltage specification for the wiring unit section conforms to JISC0704, Grade 1 or its equivalent.
How to Order Valve Manifold
�SS5YJ5-41P-07-C4-Q ········1 pc.(Manifold base)
SYJ5143-5LOU-Q ················3 pcs.(Valve)
SYJ5243-5LOU-Q ················3 pcs.(Valve)
SYJ5000-21-3A-Q ················1 pc.(Blank plate ass'y)
SY3000-37-3A ··················3 pcs. (Connector ass'y)
SY3000-37-4A ··················3 pcs. (Connector ass'y)
∗Use manifold specifications sheet.
20P 41P 43P
A, B port
Body portedSYJ5�23
Base mountedSYJ5�43
__
M5
__
3.2 (176.77)2.9 (157.04)
__
M5C4 (ø4 One-touch fitting)C6 (ø6 One-touch fitting)
Specify the part numbers for the valve(s), blank plate ass'y, and manifold base.
Example
ModelManifold style
P (SUP), R (EXH) style
Valve stations
A, B portspecifications
Port size
Valve effective areamm2(Nl/min) (1)
The manifold can be wired for either positive or negative common because only non-polar valves are used.The use of valves other than non polar types are not recommended. It may cause damage to the electrical circuit.
Caution
How to Order Valve
How to Order Connector Ass'ySYJ5
12345
5 LOU
2 position single solenoid2 position double solenoid3 position closed centre3 position exhaust centre3 position pressure centre
ConfigurationA/B port size
56
24V DC12V DC
Single solenoid SY3000-37-28A
SY3000-37-29A
SY3000-37-40A
SY3000-37-41A
Double solenoid3 position
Singlewith interface ass'y
Double solenoid 3 position with inter face ass'y
Rated voltage
For 12V/24V DC
Note) Flat cable style: "U" type is for DC specification. Contact SMC for other specifications.
1 324
—DE
Non-locking push stylePush-turn-locking slotted stylePush-turn-looking knob style
Manual override
—M5C4C6
Base mountedM5
ø4 One-touch fittingø6 One-touch fitting
DC -Q
Protective classclass III (Mark: )
1.3-41
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
20 Type (5 Port/Body ported)
41 Type (5 Port/Base mounted)
42 Type (5 Port/Base mounted )
How to Order Applicable solenoid valveSYJ5�20-����-
SYJ5�23-����-
Applicable blank plateassemblySYJ5000-21-1A-QApplicable individualexhaust spacer assemblySYJ5000-17-1A-Q
Applicable solenoid valveSYJ5�40-����SYJ5�43-����SYJ5�50-����SYJ5�53-����
Applicable blank plateassemblySYJ5000-21-1A-2-Q
How to Order
02
:
20
2 stations
:
20 stations
Stations
How to Order
01
C6
Rc(PT)
ø6 One-touch fitting
A, B port side
Common SUP/Common EXH
40 Type (5 Port/Base mounted) Applicable solenoid valveSYJ5�40-����SYJ5�43-����SYJ5�50-����SYJ5�53-����Applicable blank plateassemblySYJ5000-21-1A-2-Q
How to Order
02
:
20
2 stations
:
20 stations
Stations
Note) For more than 8 stations, supply air to both sides of "P" port and exhaust air from both "R" port.
02
:
20
2 stations
:
20 stations
Stations
02
:
20
2 stations
:
20 stations
Stations
M5 M5
A, B port side
M5-QC4-QC6-QM5-QC4-QC6-Q
Applicable individualexhaust spacer assemblySYJ5000-17-1A-2-Q
Applicable interfaceregulator assemblyARBYJ5000-00-P-Q
M5 M5
A, B port side
Applicable individualexhaust spacer assemblySYJ5000-17-1A-2-Q
Applicable individualsupply spacer assemblySYJ5000-16-2A-2Q
Applicable interfaceregulator assemblyARBYJ5000-00-P-2Q
43 Type (5 Port/Base mounted) How to Order
C4 ø4 One-touch fitting
A, B port side
02
:
20
2 stations
:
20 stations
Stations
A, B portC4
R port
P port
A, B port
R port
P port
A, B portM5
R port
P port
A, B portM5
P port
R port
A, B portM5
P port
R port
SS5YJ5-- 41-- 05 --M5
SS5YJ5--20-- 05
SS5YJ5-- 40-- 05 -- M5
SS5YJ5-- 42-- 05 -- C6
SS5YJ5-- 43-- 05 -- C4
1 8
1 8
1 8
1 8
1 8
1 8
1 4
1 4
1 8
1 8
1 8, C61 8
-Q
00F-
G(PF)Rc(PT)
00T00N
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
Protective classclass III (Mark: )
-Q
-Q-Q
-Q
-Q
-Q-Q
-Q
1.3-42
Series SYJ5000
20P Type (5 Port/Body ported)
41P Type (5 Port/Base mounted)
How to Order Applicable solenoid valveRefer to the p.1.2-41.
Applicable blank plate assemblySYJ5000-21-3A-Q
How to Order
SS5YJ5--41P-- 05 --M5
03
:
12
3 stations
:
12 stations
Stations
Flat Cable Manifold
03
:
12
3 stations
:
12 stations
Stations
Common SUP/Common EXH Note) For more than 8 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base
Applicable manifold baseSS5YJ5-20
SYJ5000-21-1A-1-Q
Blank Plate Assembly
Applicable manifold baseSub-plateSS5YJ5-40SS5YJ5-41SS5YJ5-42SS5YJ5-43
Applicable connector assemblyRefer to the p.1.3-41.
43P Type (5 Port/Base mounted) How to Order
SS5YJ5--43P-- 05 --C4
03
:
12
3 stations
:
12 stations
Stations
Applicable solenoid valveRefer to the p.1.3-41.
Applicable blank plate assemblySYJ5000-21-3A-Q
Applicable connector assemblyRefer to the p.1.3-41.
Applicable manifold baseSS5YJ5-20
A, B port
P port
R port
P port
R port
A, B portM5 X 0.8
P port
R port
A, B portC4
Phillips head screwM2.5 X 25, mattednickel plated(With spring washer)
Phillips head screwM2.5 X 7, mattednickel plated(With spring washer)
GasketDXT192-10-14
GasketDXT192-10-15
GasketDXT192-10-16
Blank plateSYJ5000-21-1
SS5YJ5--20P-- 05
SYJ5000-21-3A-1-Q
Applicable manifold baseSS5YJ5-20PSS5YJ5-41PSS5YJ5-43P
Phillips head screwM2.5 X 7, Mattednickel plated(With spring washer)
GasketDXT192-10-15
Blank plateSYJ5000-21-1
Dust capSY3000-42-1
1 8
1 8
1 8
1 8
1 8
1 8
-Q
00F-
G(PF)Rc(PT)
00T00N
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
Applicable manifold baseSS5YJ5-40SS5YJ5-41SS5YJ5-42SS5YJ5-43
SYJ5000-21-1A-2-Q
1.3-43
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Individual EXH Spacer Ass'y
Installation of the SYJ500 Valve on the SYJ5000 Manifold
Applicable manifold baseSS5YJ5-20
SYJ5000-17-1A-1-Q
Applicable manifold baseSS5YJ5-40SS5YJ5-41SS5YJ5-42SS5YJ5-43
Applicable mainfold baseSS5YJ5-20
Individual SUP Spacer Ass'y
SYJ5000-16-2*A-Q
Applicable manifold baseSS5YJ5-41SS5YJ5-42SS5YJ5-43
Interface Regulator (P regulation)
ARBYJ5000-00-P-Q
Applicable manifoldbaseSS5YJ5-40SS5YJ5-41SS5YJ5-42SS5YJ5-43
�Use of an adapter plate makes it possible to mount series SYJ500 on the manifold bases of series SYJ5000.�When mounting the SYJ500 valve on the SYJ5000 manifold, the SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid SYJ5000. (See the figure below.)�For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.
Putting interface regulator on the manifoldbase makes it possible to reduce supplypressure to a valve individually.
Adapter plate ass'ySYJ500-3-1A-1-Q
R5
R3
2-M5 (R port)
R
2-M5 (R3,R5 port)
Series SYJ500Body ported
Series SYJ500Base mounted
Base mounted
Body Ported Base mounted
P
2-M5 (P port)
Base mounted
Adapter plate ass'ySYJ500-3-1A-2-Q
Applicable mainfold baseSS5YJ5-40SS5YJ5-41SS5YJ5-42SS5YJ5-43
R
SYJ5000-17-1A-2-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
With position pin With position pin
1.3-44
Series SYJ5000
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗Other dimensions are the same as the grommet style. ∗Other dimensions are the same as the grommet style.
≅ 300
(Lead wire length)
25840
37456
49072
510688
6122104
7138120
8154136
9170152
10186168
11202184
12218200
13234216
14250232
15266248
16282264
17298280
18314296
19330312
20346328
StationsL1
L2
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
12.5
16.5
16.5
23.5
49
6-1/8(P, R port)
2-One-touch fitting(A, B port)Applicable tubeC4: T0425C6: T0604
C4: (3)C6: (3.2) 52.8
≅ 30
0
(Lea
d w
ire le
ngth
)
123
107
0.6
37.6
50
77
103.
8
87.8
69
61.1
43.5
0.6
Built-in One-touch fitting
20 Type Manifold: Top Ported/SS5YJ5-20- Station
50
37.6
31
20
(Non-locking)Manual override
A
B
A
B
A
B
A
B
A
B
RR
P
RR
P
(Pitch) P = 16
2.5 2.5
0.8
46.2
67.1
(GZ,
GS:
67.
8)
20.1
(G
Z, G
S: 2
0.8)
9
103.
2 (G
Z, G
S: 1
04.6
)
35.5
(GZ,
GS
: 36.
2)
46.8
14.6
16.5
15.2
1018
.5
L2
L1
2n-M5(A, B port)
4-ø4.5(Mounting holes)
Depress and turn tooperate and lock override.
Manual override
21
�-Q
1.3-45
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
25840
37456
49072
510688
6122104
7138120
8154136
9170152
10186168
11202184
12218200
13234216
14250232
15266248
16282264
17298280
18314296
19330312
20346328
StationsL1
L2
MAX: 13.5
5.5 43.5
103.
8
87.8
69
61.1
0.6
≅ 3
00
(Lea
d w
ire le
ngth
)
123
107
0.6
37.6
50
77
Built-in speed controller
6-1/8(P, R port)
13
4733
8.5
2.5
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
40 Type Manifold: Bottom Ported/SS5YJ5-40- Station -M5
A A
BB
2n-M5(A, B port)
12 24
23
(Pitch)P=16
50
37.6
31
20(Non-locking)
Manual override
≅ 300
(Lead wire length)
RR
P
A
B
A
B
A
B
A
B
A
B
L2
L1
RR
P
944.2
(GZ,
GS:
44.
9)38
.1
22.7
23.3
103.
2 (G
Z, G
S: 1
04.6
)
(Pitch)P=16
43.6
(GZ,
GS
: 44.
3)
16.5 22
.723
.5
4-ø4.5(Mounting holes)
87.2
(G
Z, G
S: 8
8.6)
Depress and turn tooperate and lock override
Manual override
21
�-Q
1.3-46
Series SYJ5000
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
≅ 300(Lead wire length)
25243
36859
48475
510091
6116107
7132123
8148139
9164155
10180171
11196187
12212203
13228219
14244235
15260251
16276267
17292283
18308299
19324315
20340331
StationsL1
L2
MAX: 13.5
5.5 47.5
123
107
0.6
41.6
54
69.5
103.
8
87.8
61.5
65.1
0.6
4-1/8(P, R port)
12
35217
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
Built-in speed controller
41 Type Manifold: Side Ported/SS5YJ5-41- Station -M5
RP
L2
L1
RP
43 (G
Z, G
S: 4
3.7)
39.3
22.1
103.
2 (G
Z, G
S: 1
04.6
)
P=16(Pitch)
27.6
(GZ,
GS:
28.
3)
3.5
17.5
6.7
38.7
2-ø5.5(Mounting holes)
59.6
(GZ,
GS:
60.3)
BB B B B
A
4.5
A A A A
13.5
Depress and turn tooperate and lock override
Manual override
A
B
A
B
54 [6
0.5]
41.6
35
24
13
(Pitch)P=16
2n-M5 (A, B port)
5.5
18.5
(Non-locking)Manual override
≅ 30
0(L
ead
wire
leng
th)
� -Q
1.3-47
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
StationL1
L2
L1
L2
266536552
383708168
4100879784
5117104113100
6134121129116
7151138145132
8168155161148
9185172177164
10202189193180
11219206209196
12236223225212
13253240241228
14270257257244
15287274273260
16304291289276
17321308305292
18338325321308
19355342337324
20372359353340
A, B port size
Rc(PT)1/8
C6(ø6 One-touch fitting)
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
C6 (Built-in One-touch fitting)
∗ Other dimensions are the same as the grommet style.
123
107
0.6
50.6
63
74.5
A
B
A
B
63
50.6
44
33
20(Pitch) P=16
2n-One-touch fitting(A, B port)
8.5
25
1
4-1/4(P, R port)
10.5
17.5
24 44
MA
X.6
4-1 4
(P, R port)
10.5
17.5
24 44
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
≅ 30
0(L
ead
wire
leng
th)
103.
8
87.8
66.5
74.1
0.6
≅ 300(Lead wire length)
G: ≅
300
(Lea
d w
ire le
ngth
)
56.5
Applicable tube: T0604
42 Type Manifold: Side Ported/SS5YJ5-42- Station -01,C6
MAX: 13.5
5.5 56.5
G: ≅
300
(Lea
d w
ire le
ngth
)
Built-in speed controller
L2
L1
38 (G
Z, G
S: 3
8.7)
44.3
17.1
103.
2 (G
Z, G
S: 1
04.6
)
P=17(Pitch)
22.6
(GZ,
GS:
23.
3)1.7
23
43.7
2-ø6.5(Mounting holes)
64.6
(GZ,
GS:
65.
3)
6.5
18R
P
PR
BB B B B
A A A A A
Depress and turn tooperate and lock override
Manual override
A
B
A
B
63
50.6
44
33
24.5(Pitch)
P=17
2n-1/8(A, B port)
8.5
24.5
6
(Non-locking)Manual override
(Non-locking)Manual override
� -Q
1.3-48
Series SYJ5000
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
25243
36859
48475
510091
6116107
7132123
8148139
9164155
10180171
11196187
12212203
13228219
14244235
15260251
16276267
17292283
18308299
19324315
20340331
StationsL1
L2
123
107
0.6
41.6
54
72
64
103.
8
87.8
65.1
0.6 47.5
4-1/8(P, R port)
12
3717.5
11.5
MA
X.5
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
≅ 300
(Lead wire length)
≅ 30
0
(Lea
d w
ire le
ngth
)
43 Type Manifold: Side Ported/SS5YJ5-43- Station -C4
MAX: 13.5
5.5 47.5
≅ 30
0
(Lea
d w
ire le
ngth
)Built-in speed controller
L2
L1
40.5
(GZ,
GS:
41.
2) 41.8
19.6
103.
2(G
Z, G
S: 1
04.6
)
P=16
(Pitch) (GZ,
GS
: 25.
8)
1
4.2
25.1
41.2
2-ø5.5(Mounting holes)
62.1
(GZ,
GS:
62.8)
4.5
13.5
20.3
RP
BB B B B
A A A A A
RP
Depress and turn tooperate and lock override
Manual override
A
B
A
B
54 [6
0.5]
41.6
35
24
13.7
(Pitch)P=16
2n-One-touch fitting(A, B port)
6
18
Applicable tube: T0425
(Non-locking)Manual override
� -Q
1.3-49
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
StationsL1
L2
494.576.5
511294
6129.5111.5
7147129
8164.5146.5
9182164
10199.5181.5
11217199
12234.5216.5
Flat Cable Manifold
37759
StationL1
L2
494.579.5
511297
6129.5114.5
7147132
8164.5149.5
9182167
10199.5184.5
11217202
12234.5219.5
37762
C4, C6(Built-in One-touch fitting)
Built-in speed controller
7.8
24 29
28.5
47.554
Polarity indication
Applicable connector: 26-pole MIL type(Conforms to MIL-C-83503)
SS5YJ5-20P- Station 23
.549
16
16.5
16.5
12.5
6-1/8(P, R port)
C4: (3)C6: (3.2) 52.8
2-One-touch fitting(A, B port)Applicable tube C4: T0425 C6: T0604
SS5YJ5-41P- Station -M5
12
217
3516
4-1/8(P, R port)
31
(Non-locking)Manual
35
5.5
18.5
2n-M5(A, B port)
(Pitch) P=17.5 26
BA
BA
(Non-locking)Manual
2-ø5.5(Mounting holes)
123
39.3
22.1
17.5
69
69.538
.73.
5
Triangle mark
L1
L2 7.5
13.5(Pitch)P = 17.5
A Side
B
A
B
A
B
A
B
A
B
A
37.5
6.7
70.1 R
P
B Side
PR
(Non-locking)Manual override
5020 5.
8
24.3
28.5Polarity indication
Applicable connector: 26-pole MIL type(Conforms to MIL-C-83503)
RR
P
4-ø4.5(Mounting holes)
123
77.6
77
82.845
.40.
830
46.8
14.6
18.5
10
15.2
16.5
Triangle mark
L1
L2 9
12
2.52.5
(Pitch)P=17.5
A Side2n-M5(A, B port)
B Side
RR
P
BA
BA
BA
BA
BA
Depress and turn tooperate and lock override
Manual override
MAX: 13.55.5
� -Q
�-Q
1.3-50
Series SYJ5000
StationsL1
L2
494.579.5
511297
6129.5114.5
7147132
8164.5149.5
9182167
10199.5184.5
11217202
12234.5219.5
Flat Cable Manifold
37762
MAX: 13.55.5
7.8
24 29
28.5
47.554
Polarity indication
Applicatable connector: 26-pole MIL(Conforms to MIL-C-83503) Built-in speed controller
SS5YJ5-43P- Station -C4
35
618
2n-One-touch fitting(A, B port)Applicable tube: T0425
(Pitch)P=17.5 25.3
BA
BA
(Non-locking)Manual override
12
17.5
11.5
37
4-1/8(P, R port)
MA
X.5
16
2-ø5.5(Mounting holes)
123
41.8
19.6
20.3
71 72
41.2
1
Triangle mark
L2 7.5
13.5(Pitch)P=17.5
A Side
B Side
354.2
72.6 R
P PRB
A
B
A
B
A
B
A
B
A
L1
Deperess and turn tooperate and lock override.
Manual override
� -Q
1.3-51
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ5000
Series SYJ7000Model
Valve model Configuration Port size
11 (588.90)11 (588.90)8.5 (461.31)
9 (490.75) [6.5 (353.34)]P�A, B: 13.5 (736.13)
[7 (382.79)]A, B�R1, R2: 7 (382.79)
8.6 (471.12)8.6 (471.12)7.1 (382.79)
8.4 (461.31) [6.2 (333.71)]P�A, B: 7.7 (412.23)
[5.5 (294.45)]A, B�R1, R2: 7.1 (382.79)
9.9 (539.83)9.9 (539.83)8.2 (451.49)
9.7 (530.01) [6.7 (363.16)]P�A, B: 9.3 (510.38)
[5.6 (294.45)]A, B�R1, R2: 7.6 (412.23)
12.6 (687.05)12.6 (687.05)8.5 (4461.31)9 (490.75) [6.5 (353.34)]P�A, B: 13.5 (736.13)
[7 (382.79)]A, B�R1, R2: 7 (382.79)
Weight (g)
Grommet
8292
102
93103
113
93103
113
162 (82)172 (92)
182 (102)
L / Mplug connector
8496
106
95107
117
95107
117
164 (84)176 (96)
186 (106)
2 position
3 position
2 position
3 position
2 position
3 position
2 position
3 position
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
SingleDouble
Closed centreExhaust centre
Pressure centre
1/8
A, B port : C6 ø6 One-touch
fittingP, R port
: 1/8
A, B port : C8 ø8One-touch
fittingP, R port
: 1/8
1/81/4
( )
( )
Fluid
Specifications
Operating pressure range(MPa)
Ambient and fluid temperature(°C)Response time (ms) at 0.5MPa (4)
Max.operating frequency (Hz)
Manual overridePilot exhaustLubricationMounting orientationImpact/Vibration resistance (m/s2) (5)
Protection structure
2 position single2 position double
3 position
2 position single, double3 position
2 position single, double3 position
Air0.15 to 0.70.1 to 0.70.15 to 0.7
Max.50≤ 30≤ 60
53
Non-locking push, Push-turn-locking slotted styleIndividual pilot exhaust, Common exhaust (pilot and main valve)
Not requiredUniversal150/30
Dust proof
Solenoid SpecificationsElectrical entryCoil reted voltage (V)Allowable voltagePower consumption (W)Surge voltage suppressorIndicator light
Grommet (G)/(H), L plug connector (L), M plug connector (M)24, 12, 6, 5, 3
�10% rated voltage0.5 (With light: 0.55)
DiodeLED
0102
JIS Symbol
2 position double
2 position single
3 position closed centre
3 position exhaust centre
3 position pressure centre
Body ported
2 position double solenoid
2 position single solenoid
3 position closed centre
3 position exhaust centre
3 position pressure centre
Base mounted
Body ported
Base mounted
DC
DC
Effectivearea
mm2(Nl/min)
5 Port Solenoid ValveRubber Seal
(B)2
1(P)
5(R1)
3(R2)
1(P)
3(R2)
5(R1)
(A)4
(B)2
(A)4
(B)2
1(P)
5(R1)
3(R2)
1(P)
3(R2)
5(R1)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
(A)4
1(P)
3(R2)
5(R1)
(B)2
(A)4
1(P)
3(R2)
5(R1)
(B)2
(A)4
1(P)
3(R2)
5(R1)
(B)2
(A)4
(1) (2)
Bod
y po
rted
Bas
e m
ount
ed
(6)
SYJ7�20- -01
SYJ7�20- -C6
SYJ7�20- -C8
SYJ7�40- -
Note 1) In case of M5 and mounted on monifold base.Note 2) ( ): Without sub-plate.
Note 6) At rated voltage
Note 4) According to dynamic performance test JIS B8375-1981 (Coil temperature 20°C, at rated voltage, without surge voltage suppressor)Note 5) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test
was performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. (Value in the initial stage)
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000Hz. Test was performed at both energized and de-energized states to axis and right angle direction of the main valve and armature. (Value in the initial stage)
� -Q
� -Q
� -Q
� -Q
1.3-52
Cylinder Maximum Operating Speed
• System Figure �
System components
System Solenoid valve
AS2301F-01-04
AS3301F- -06
AS3301F- -08
AS3301F- -10
AS4001F-12
SilencerFitting
(Tube O.D. X Port size)
Solenoid valve
Silencer
Fitting
Speed controller
• System Figure �
Operating conditions: Pressure 0.5MPa, Load rate 50%At cylinder extended, cylinder stroke CM2: 300mm
CA1: 500mm
Solenoid valve
Silencer
Fitting
Speed controller
SYJ7�40-021/4
(S = 12.6mm2)
AN200-02(S = 35mm2)
SYJ7�40-011/8
(S = 12.6mm2)
0203
0203
0203
AN110-01(S = 35mm2)
ø4 X 1/8
ø6 X 1/4
ø8 X 1/4
ø10 X 1/4
ø12 X 1/4
—
—
—
—
ø12 X 1/2
900
1000
800
500
600
700
400
300
200
100
20 25 32 40 40 50 63 80 100
Piping length 1m
CM2 cylinder CA1 cylinder
Piping length 5m
D
B
C
E
B
A
Max
.ope
ratin
g sp
eed
(mm
/s)
Cylinder bore size (mm)
Fitting
Speed controller Systemfigure
Air
cylin
der
Air
cylin
der
A
B
C
D
E
q
w
1.3-53
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
How to Order
SYJ7 2
SYJ7 4
12345
2 position single solenoid2 position double solenoid3 position closed centre3 position exhaust centre3 position pressure centre
ConfigurationLight and surge voltage suppressor
56VSR9
24V DC12V DC6V DC5V DC3V DC
(Less than 50 VDC)
Rated voltageFor DC
Body option
01C6C8
Rc(PT)1/8ø6 One-touch fittingø8 One-touch fitting
A/B port size
Note) R1and R2 port size1/4
5 M
M
1
2 5
0
0
01
Bracket
—: Without bracketF: With bracket
Port size—: Without sub-plate
01: With 1/8 sub-plate Note)
(With gasket and screws)
02: With 1/4 sub-plate
Manual override—: Non-locking push style
D: Push-turn-locking slotted style
R port P, E port
0: Individual exhaust forthe pilot valve
3: Common exhaust forthe pilot and main valve
R port P, E port
(For manifold type 20, 21)
For sub-plate,manifold type 40, 41, 42
Base mounted
Body ported
G: 300mm lead wire
L: 300mm lead wire
M: 300mmlead wire
MN: Withoutlead wire
H: 600mmlead wire
LN: Withoutlead wire
LO: Withoutconnector
MO: Withoutconnector
∗LN and MN types are with 2 pcs. of socket.
Electrical entry24V, 12V, 6V, 5V, 3V DC
Grommet L plug connector M plug connector
—SZU
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
"U" types are available for DC voltage valves.
Note)Do not remove the factory installed bracket from modelswith the bracket option.Removal of the bracketwill cause the valveto leak.
-Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
-Q
Protective classclass III (Mark: )
Contact SMC for other voltages (9)OrderMade
1.3-54
Series SYJ7000
SY114
56VSR
Construction
Replacement PartsNo.
Sub-plate
Pilot valve
NoteParts No.SYJ7000-22-1-QSYJ7000-22-2-Q
SY114-���
How to Order Pilot Valve Assembly
5 G
24V DC12V DC6V DC5V DC3V DC
: SY100-30-4A-
: SY100-30A
—6101520253050
300mm600mm1000mm1500mm2000mm2500mm3000mm5000mm
Aluminumdie cast
1/81/4
A A B
R1 P R2
B
A B
R1 P R2
R1 P R2
(This construction shows a closed centre.)
—
2 position single 2 position double
3 position closed centre/exhaust centre/pressure centre
3 position closed centre
3 position exhaust centre
3 position pressure centre
Component PartsNo.
BodyPiston plateEnd coverPistonSpool ass,ySpool spring
MaterialAluminum die cast
ResinAluminum die cast
Resin—
SUS
Notewhitewhitewhite
———
Description Description
How to Order Connector Assembly
DC:
Without lead wire(with connector and 2 pcs. of socket) Lead wire length
Voltage
Electrical entryGHL
LNLOM
MNMO
Grommet (Lead wire length: 300mm)Grommet (Lead wire length: 600mm)
With lead wireWithout lead wireWithout connectorWith lead wireWithout lead wireWithout connector
L plugconnector
M plugconnector
(A)4
5(R1)
3(R2)
1(P)
(B)2
(A)4
5(R1)
3(R2)
1(P)
(B)2
(A)4
5(R1)
3(R2)
1(P)
(B)2
(A)4
5(R1)
3(R2)
1(P)
(B)2
(A)4
5(R1)
3(R2)
1(P)
(B)2
qwerty
u
i
Light and surge voltage suppressor—SZU
Without light and surge suppressorWith surge suppressorWith light and surge suppressorWith light and surge suppressor (Non-polar)
ey q t
t q r w
i
r w w q t r
i
u
i
-Q
-Q
1.3-55
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet (G), (H): SYJ7120- � ��-01
L plug connector(L): SYJ7120- �L���-01 M plug connector (M): SYJ7120- �M��-01
2 Position Single
With bracket
∗ Other dimensions are the same as the grommet style.
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
(Mounting holes)
31.1
28 25 21
35
28.3
77.182 (GZ, GS: 82.7)
2-ø3.2G: ≅ 300H: ≅ 600
(Lead wire length)
1.6
5-1/8(Piping port)
27.2
R1 P R2
44
36
34
27.9
18 26 34
(Mounting holes)
2-ø4.5
85.6
(G
Z, G
S: 8
6.3)
3.6
(Bracket)
2-One-touch fitting(A, B port)Applicable tube C6: T0604 C8: T0806
36(4
.9)
A B
17
GH
34
15.3
21.6
10
18
(Mounting holes)
31.1
28 25 21
35
28.3
77.1
2-ø3.2 (Mounting holes)
31.1
28 25 21
35
28.3
77.1
2-ø3.2
45.1
3415
10
18
≅ 3
00
(Le
ad w
ire le
ngth
)
( Mounting holes for manifold )
13 3
17
78.3
82.3
35
61.1
2-ø3.2
A B
(Mounting holes for maniford)
13 3
17
91.9
35
≅ 300
(Lead wire length)
61.1
2-ø3.2
A B
Built-in One-touch fitting:SYJ7120-� ��-G
HC6C8
(Mounting holes for manifold )
13 3
17
35
61.181.2 (GZ, GS: 82.2)
2-ø3.2
A B
Depress and turn tooperate and lock override.
Manual override
34
21.6
15
28
10
18
(Non-locking)Manual override
� -Q
� -Q
� -Q � -Q
1.3-56
Series SYJ7000
Grommet (G), (H): SYJ7220-� ��-01�-Q
L plug connector(L): SYJ7220-�L��-01� -Q M plug connector (M):SYJ7220- �M��-01� -Q
2 Position Double
Built-in One-touch fittingSYJ7220-� ��-
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
97.6
35
2125
31.1
107.4 (GZ, GS: 108.8)
2-ø3.2(Mounting holes)
27.21.6
5-1/8(Piping port)
R1 P R2
(A, B port) Applicable tube C6: T0604 C8: T0806
2-One-touch fitting
36(4
.9)
108
100
3
1735
65.6(Mounting holes for manifold)
13
2-ø3.2
A B
18
10
15 21.6 28 34
GH
GH
C6C8
97.6
35
2125
31.1
(Mounting holes) 2-ø3.2
105.8 (GZ, GS: 107.8) (Mounting holes for manifold)
17
35
65.6
13
3
2-ø3.2
A B
Depress and turn tooperate and lock override
Manual override
15
28
21.6 34
10
18
-+
(Non-locking)Manual override
(Mounting holes)
97.6
2125
31.1
35
2-ø3.2
10
18
1528
3445.1
≅ 3
00
(Le
ad w
ire le
ngth
)
17
A B
173565.6
127.2
3
13
(Mounting hole for manifold) 2-ø3.2
A B
≅ 300
(Lead wire length)
� -Q
1.3-57
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet (G), (H): SYJ7 20-� ��-01� -Q
3 Position Closed Centre/Exhaust Centre/Pressure Centre
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
L plug connecter (L): SYJ7 20- L -01 M plug connector (M): SYJ7 20-�M��-01
1.6
5-1/8(Piping port)
R2
27.2
R1 P
G: ≅ 300H: ≅ 600
(Lead wire length)35(Mounting holes)
31.1
25 21
62.6 54.5 (GZ, GS: 55.2)49.6
122 (GZ, GS: 123.4)
2-ø3.2
28
15 21.6 34
10
18
Manual override(Non-locking)
17
A B
36(4
.9)
2-One-touch fitting (A, B port) Applicable tube C6: T0604 C8: T0806
Built-in One-touch fitting:SYJ7 20-� -��
34
15 21.6 28
10
18
35
(Mounting holes)
31.1
25 21
49.6
112.2
2-ø 3.2
35(Mounting holes)
31.1
25 21
49.6
112.2
2-ø3.2
34 5
345
345
GH
345
GH
C6C8
46.6
63.8
122.6
33.6
50.8 54.8
3
35
17
(Mounting holes for manifold)
13B
2-ø 3.2
AA
46.6
141.8
33.6
64.4
3
35
17
(Mounting holes for manifold)
13
2-ø3.2
A B
≅ 300
(Lead wire length)
45.1
342815
10
18
≅ 3
00
(Lea
d w
ire le
ngth
)
46.6
120.4 (GZ, GS: 122.4)
33.653.7 (GZ, GS: 54.7)
3
35
17
(Mounting holes for manifold)
13A B
2-ø3.2
Manual overrideDepress and turn tooperate and lock override
� -Q
���� -Q �-Q
1.3-58
Series SYJ7000
Grommet (G), (H): SYJ7140- � ��-
L plug connector (L): SYJ7140-�-��- M plug connector (M): SYJ7140- �M��-
2 Position Single
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
22 22
63
31.5
11.5
12
2057
.1
3-1/4, 1/8
(P, A, B port)
2-1/4 (R1, R2 port)
22 22
63
31.5
11.5
1220
57.1
(P, A, B port)
(R1, R2 port)
3-1/4, 1/8
2-1/4
2-1/4 2222
63
31.5
11.5
12
2057
.1
(P, A, B port)3-1/4, 1/8
(R1, R2 port)
B
A
A
R2 R1P
≅ 300
(Lead wire length)95.1
64.3
34 8.5
27 34
(Mounting holes)
B
2-ø4.3
A
A
R2 R1P
85.5 81.5
64.334 8.5
27 34
(Mounting holes)
B
2-ø4.3
B
GH
0102
10
41.6
25.5 41
54 60
18
Manual override (Non-locking)
0102
0102
22
12
20.5
B
A
A
R2 R1P
G: ≅ 300H: ≅ 600
(Lead wire length)
85.2 (GZ, GS: 85.9) 84.4 (GZ, GS: 85.4)
64.3
34 8.527 34
(Mounting holes)
B
2-ø4.3Depress and turn tooperate and lock override.
Manual override
10
25.5 41
54 60 71.1
18
≅ 3
00
(Lea
d w
ire le
ngth
)
�-Q
�-Q �-Q
10
25.5 41 47
.6 54 60
18
1.3-59
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet (G), (H): SYJ7240-� ��-
L plug connector (L): SYJ7240-�L��- M plug connector (M): SYJ7240- �M��-
2 Position Double
∗ Other dimensions are the same as the grommet style.∗ Other dimensions are the same as the grommet style.
GH
0102
0102
0102
10
47.6
25.5 41
54 60
18
Manual override(Non-locking)
10
25.5 41
5460 71
.1≅
300
(Lea
d w
ire le
ngth
)
1822 22
63
11.5
12
2057
.1
(P, A, B port)3-1/4, 1/8
(R1, R2 port)2-1/4
27 34
B
AA
R2 R1P
≅ 300
(Lead wire length)127.2
65.6
31.5
34
1.3
B
(Mounting holes)2-ø4.3
8.5
22 22
63
11.5 12 20
57.1
(R1, R2 port)2-1/4
(P, A, B port)
3-1/4, 1/8
B
A
A
R2 R1P
108 10065.6
31.5
34 8.5
1.3
27 34
B
(Mounting holes)2-ø4.3
B
A
A
R2 R1P
G: ≅ 300H: ≅ 600
(Lead wire length)
107.4 (GZ, GS: 108.8) 105.8 (GZ, GS: 107.8)
65.6
31.5
34 8.5
1.3
27 34
B
21.4 (GZ, GS: 22.4)
(Mounting holes)2-ø4.3
22.2 (GZ, GS: 22.9) Depress and turn tooperate and lock override
Manual override
22
12
20.5
22 22
63
11.5
12
20
57.1
3-1/4, 1/8 (P, A, B port)
2-1/4(R1, R2 port)
10
25.5 41 47
.6 54 60
18
�-Q
�-Q �-Q
1.3-60
Series SYJ7000
Grommet(G), (H): SYJ7 40-� ��-
3 Position Closed Centre/Exhaust Centre/Pressure Centre
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
M plug connector (M): SYJ7 40-�M��-L plug connector (L): SYJ7 40-�L��-
10
25.5
41 47.6 54 60
18 10
25.5
4154 71
.1
18
≅ 30
0
(Lea
d w
ire le
ngth
)
27 34
B
A
A
R2 R1P
141.8
65.1 45.9
31.5
34 8.5
15.1
B
(Mounting holes)2-ø4.3
≅ 300
(Lead wire length)
B
A
A
R2 R1P
122.6 36.3 82.3
65.131.5
34 8.5
15.132.3
27 34
B
(Mounting holes)2-ø4.3
10
47.6
25.5 41
5460
18
Manual override(Non-locking)
345
GH
0102
345
0102
345
0102
B
A
A
R2 R1P
122 (GZ, GS: 123.4) 120.4 (GZ, GS: 122.4)
65.1
31.5
34 8.5
15.1
27 34
B
36 (GZ, GS: 36.7)
35.2 (GZ, GS: 36.2)
(Mounting holes)2-ø4.3
G: ≅ 300H: ≅ 600
(Lead wire length)
Depress and turn tooperate and lock override.
Manual override
22 2263
11.5
12
20
57.1
(P, A, B port)
3-1/4,1/8
(R1, R2 port)
2-1/4
22 22
63
11.5 12 20
57.1
3-1/4,1/8
(P, A, B port)
2-1/4(R1, R2 port)
22
12
20.5
22 22
63
11.5
12
20
57.1
(P, A, B port)
3-1/4,1/8
(R1, R2 port)2-1/4
�-Q
�-Q �-Q
1.3-61
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
ManifoldSeries SYJ7000
Standard
Location
Direction
P, R port
A, B port
Body portedSYJ7�2�
Base mountedSYJ7�4�
Valve
Top
1/8: 11 (588.90) C6: 8.6 (471.12) C8: 9.9 (539.83)
Single base style/B mount
Common SUP, Common EXH
Manifold Specifications
Type
Manifold style
P (SUP), R (EXH) style
Valve stations
A, B port specifications
Port size
Valve effective areamm2(Nl/min)
__ __ __
1/8
Base
Side
Note 1) Value for a single solenoid 2 position valve mounted on the manifold.
How to Order Valve ManifoldSpecify the part numbers for the valve(s), blank plate ass'y, and manifold base.
Example �SS5YJ7-20-03-Q ................1 pc. (Manifold base)
SYJ7120-5G-01-Q ..............2 pcs. (Valve)
SYJ7000-21-1A-Q .............1 pc. (Blank plate ass'y)
�SS5YJ7-41-03-01-Q ..........1 pc. (Manifold base)
SYJ7140-5LZ-Q .................1 pc. (Valve)
SYJ7240-5LZ-Q .................1 pc. (Valve)
SYJ7000-21-1A-Q .............1 pc. (Blank plate ass'y)
∗ Use manifold specification sheet.
20 21 40 41 42
Base
Bottom
1/4
Rc(PT)1/8C6 (ø6 One-touch fitting)C8 (ø8 One-touch fitting)
__ 11.9 (647.79) 9.5 (520.20) C6: 8.5 (461.31)C8: 9.7 (530.01)
2 to 20 stations2 to 15 stations
1/8
C6 (ø6 One-touch fitting)C8 (ø8 One-touch fitting)
__
(1)
1.3-62
Flat Cable Manifold
�Multiple valve wiring is simplified through the use of the flat cable connector.
�Clean appearance With the flat cable manifold, each valve is wired to the manifold base. A single MIL specification flat cable connects the entire manifold to the power source. This greatly reduces installation time.
Flat Cable Manifold SpecificationsType
Manifold style
P (SUP), R (EXH) sytle
Valve stations
P, R port
A, B port
A, B port specifications
Port size
Valve effective areamm2(Nl/min) (1)
Rated voltage
Connector
Internal wiring (2)
Single base style/B mount
Common SUP, Common EXH
3 to 12 stations
Valve
1/4
1/8,C6, C81/8: 11 (588.90)C6: 8.6 (471.12)C8: 9.9 (539.83)
Socket: 26 poles MIL type with strain reliefconforms to MIL-C-83503
Both for +COM and –COM
24V DC, 12V DCNote 1) Value for a single operation of 2 position valve mounted on the manifold base.Note 2) The withstand voltage specification for the unit with section conforms to JISC0704, Grade 1 or its equivalent
How to Order Valve Manifold
�SS5YJ7-21P-07-Q................1 pc.(Manifold base)
SYJ7123-5LOU-C8-Q .........3 pcs.(Valve)
SYJ7223-5LOU-C8-Q .........3 pcs.(Valve)
SYJ7000-21-3A-Q ...............1 pc.(Blank plate ass'y)
SY3000-37-42A ............... 3 pcs. (Connector ass'y)
SY3000-37-43A ............... 3 pcs. (Connector ass'y)
∗ Use manifold specification sheet.
21P
Specify the part numbers for the valve(s), blank plate ass'y, and manifold base.
Example
SYJ7�23
The manifold can be wired for either positive or negative common because only non-polar valves are used.The use of valves other than non polar types are not recommended. It may cause damage to the electrical circuit.
Caution
How to Order Valve How to Order Connector Ass'y
SYJ7
12345
5 LOU
2 position single solenoid2 position double solenoid3 position closed centre3 position exhaust centre3 position pressure centre
Configuration
—DE
Non-locking push stylePush-turn-locking slotted stylePush-turn-locking knob style
Manual override
A/B port size
56
24V DC12V DC
Single solenoid SY3000-37-42A
SY3000-37-43A
SY3000-37-44A
SY3000-37-45A
Double solenoid3 position
Singlewith spacer ass'y
Double solenoid 3 position with spacer ass'y
Rated voltage For 12V/24V DC
1 23
—01C6C8
Base mounted1/8
ø6 One-touch fittingø8 One-touch fitting
DC -Q
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
Note ) Flat cable style:"U" type is for DC specification.Contact SMC for other specifications
Protective classclass III (Mark: )
1.3-63
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
20 Type (5 Port/Body ported)
21 Type (5 Port/Body ported)
40 Type (5 Port/Base mounted)
42 Type (5 Port/Base mounted)
How to Order
Applicable solenoid valve
SYJ7�20-����-
SYJ7�23-����-
Applicable blank plateassemblySYJ7000-21-1A-1-Q
Applicable individualEXH spacer assemblySYJ7000-17-1A-Q
Applicable solenoid valveSYJ7�40-����SYJ7�43-����
Applicable blank plateassemblySYJ7000-21-1A-2-Q
Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Note) For more than 6 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
How to Order
02
:
20
2 stations
:
20 stations
Stations
How to Order
02
:
20
2 stations
:
20 stations
Stations
02
:
15
2 stations
:
15 stations
Stations
C6
C8
C6(ø6 One-touch fitting)
C8(ø8 One-touch fitting)
A, B port size
How to Order
02
:
20
2 stations
:
20 stations
Stations
01 1/8
A, B port size
Common SUP/Common EXH
41 Type (5 Port/Base mounted)
Applicable interface regulatorARBYJ7000-00-P-Q
Note) For more than 8 stations, supply air to both sides of "P" port and exhaust air fromboth sides of "R" port.
How to Order
02
:
20
2 stations
:
20 stations
Stations
Note) For more than 8 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
01C6C801C6C8
Applicable individualEXH spacer assemblySYJ7000-17-2A-Q
Applicable individualSUP spacer assemblySYJ7000-16-2A-Q
01 1/8
A, B port size
A, B port
P port 1/8
R port 1/8
A, B port
P port 1/4
R port 1/4
P port 1/4
R port 1/4 A, B port
1/8
P port 1/4
R port 1/4
A, B port 1/8
R port 1/4
P port 1/4
A, B portC6, C8
SS5YJ7--20-- 05
SS5YJ7--21-- 05
SS5YJ7--40-- 05 -- 01
SS5YJ7-- 42-- 05 -- C6
SS5YJ7--41-- 05 -- 01
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
P, R port thread-- -- Q
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
P, R port thread
P, R port thread
P, R port thread
-- -- Q
Rc (PT)G (PF)NPT
NPTF
F-
NT
-- Q
Rc (PT)G (PF)NPT
NPTF
F-
NT
-- Q
Rc (PT)G (PF)NPT
NPTF
F-
NT
P, R port thread
-- Q
-Q
-Q-Q
-Q
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
P, R port thread
-- -- Q
Flat Cable Manifold/Common SUP/Common EXH
21P Type (5 Port/Body ported)
Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
Applicable solenoid valveRefer to the below.
Applicable blank plateassemblySYJ7000-21-3A-Q
How to Order
03
:
12
3 stations
:
12 stations
Stations
R port 1/4
P port 1/4
A, B port
Applicable connectorassemblyRefer to the below.
SS5YJ7--21P-- 05
1.3-64
Series SYJ7000
Individual Exhaust Interface Ass'y
Installation of the SYJ700 Valve on the SYJ7000 Manifold
Applicable manifold baseSS5YJ7-20SS5YJ7-21
SYJ7000-17-1*A-Q
Applicable manifold baseSub-plate: SYJ7000-22-1/2*-QSS5YJ7-40SS5YJ7-41SS5YJ7-42
Applicable manifold baseSS5YJ7-20SS5YJ7-21
SYJ7000-17-2*A-Q
Applicable manifold baseSS5YJ7-40SS5YJ7-41SS5YJ7-42
Adaptor Plate Ass'ySYJ700-3-2A-Q
Applicable manifold baseSS5YJ7-40SS5YJ7-41SS5YJ7-42
�Use of an adaptor plate makes it possible to mount series SYJ700 on the manifold bases of SYJ7000 series .�Pilot valve should be installed to be located in the same side as the single solenoid of series SYJ7000 as shown in the following drawing.�For base mounted style, the A port of the 3 port valve flows out the B port of manifold base.
Pillips head screwM3 X 31, matted nickel plated(With spring washer)
GasketDXT199-21-4
GasketDXT199-21-7
R5
R3
R5
R3
2-1/8(Exhaust port)
2-1/8(Exhaust port)
With positioning pin
Pillips head screwM3 X 47, mattednickel plated(With spring washer)
R1
2-1/8(SUP port)
With positioning pin
Base mounted Base mounted
Series SYJ700Body ported type
Series SYJ700Base mounted type
SY3000-42-1
Dust cap
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base
Individual Supply Interface Ass'y Interface Regulator(P regulation)
Applicable manifold baseSS5YJ7-20SS5YJ7-21
Adaptor Plate Ass'ySYJ700-3-1A-Q
Applicable manifold baseSS5YJ7-40SS5YJ7-41SS5YJ7-42
Applicable manifold baseSS5YJ7-40SS5YJ7-41SS5YJ7-42
Refer to p.1.3-7 prior to handling
Applicable manifold baseSS5YJ7-21P
Applicable manifold baseSS5YJ7-20SS5YJ7-21
Blank Plate Assembly
SYJ7000-16-2*A-Q
SYJ7000-21-3A-Q
SYJ7000-21-1A-1-Q
ARBYJ5000-00-P-Q
Putting interface regulator on the manifoldbase makes it possible to reduce supplypressure to a valve individually.
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
With positioning pin
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
F-
G(PF)Rc(PT)
TN
NPTFNPT
Thread
With positioning pin
Applicable manifold baseSS5YJ7-40SS5YJ7-41SS5YJ7-42
SYJ7000-21-1A-2-Q
With positioning pin
1.3-65
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet(G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
25947
37866
49785
5116104
6135123
7154142
8173161
9192180
10211199
11230218
12249237
13268256
14287275
15306294
StationsL1
L2
(A, B port)Applicable tube C6: T0604 C8: T0806
2-One-touch fitting
(4.9) 60
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
34
15.5
8
50
6-1/8(P, R port)
≅ 30
0
(Lea
d w
ire le
ngth
)
88.6
141.
8
127.
20.
8
5845.6
≅ 300(Lead wire length)
80.6
108
122.
6
0.8
69.1 52
Built-in One-touch fitting
20 Type Manifold: Top Ported/SS5YJ7-20- Station
45.6
23.53958
[64.
5]
(Non-locking)Manual override
A
L1
L2 6
RR
P
122
(GZ
, GS
: 123
.4)
42.5
(G
Z, G
S: 4
3.2)
28.7
(GZ,
GS:
29.
4)
78.7
(GZ,
GS:
79.
4)
17
21.6
A A
B
A
RR
P
253.
3
57.8
7.8
58.6
P=19 20
3
BBBB
A
(Pitch)
(Mounting holes) 4-ø4.5
(A, B port)2n-1/8
Depress and turn tooperate and lock override.
Manual override
� -Q
1.3-66
Series SYJ7000
Grommet(G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
26646
38565
410484
5123103
6142122
7161141
8180160
9199179
10218198
11237217
12256236
13275255
14294274
15313293
16332312
17351331
18370350
19389369
20408388
StationL1
L2
6-1/4(P, R port)
16.5
11.5
42 60
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
0.8 54.5
71.6
108
122.
6
85.6
≅ 300
(Lead wire length)
127.
20.
8
141.
8
93.6
60.5 48.1
≅ 30
0
(Lea
d w
ire le
ngth
)
2-One-touch fitting(A, B port)Applicable tube
C6: T0604C8: T0806
(4.9) 62.5
Built-in One-touch fitting
21 Type Manifold: Top Ported/SS5YJ7-21- Station
4-ø4.5(Mounting holes)
P=19 23.5 (pitch)
3
10
17
30
63.6
122
(GZ
, GS
: 123
.4)
83.7
(GZ,
GS
: 84.
4) 37
.5 (G
Z, GS
: 38.2
)
23.7
(GZ,
GS: 2
4.4)
16.6
L2
L12n-1/8(A, B port)
RR
AB
AB
AB
AB B
P
RR
P 21
62.8
2.8
A
Depress and turn tooperate and lock override.
Manual override
48.1
41.5
26
60.5
(Non-locking)Manual override
� -Q
1.3-67
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet(G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
26646
38565
410484
5123103
6142122
7161141
8180160
9199179
10218198
11237217
12256236
13275255
14294274
15313293
16332312
17351331
18370350
19389369
20408388
StationL1
L2
16.5
11.5
0.5
6042
6-1/4(P, R port)
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)14
1.8
127.
20.
8
93.6
48.160.5
122.
6 10
8 0.
8
85.6
≅ 300
(Lead wire length)
71.6
≅ 30
0
(Lea
d w
ire le
ngth
)
40 Type Manifold: Bottom Ported/SS5YJ7-40- Station -01
122
(GZ
, GS
: 123
.4)
63.6
3016
.6
212.
8
62.8
83.7
(GZ,
GS:
84.
7)
4-ø4.5
(Mounting holes)
P=19 23.5
L2
L1
(Pitch)
10
P
RR
P
RRA AA
BBBBB
AA
37.5
(GZ,
GS:
38.
2)
23.7
(GZ,
GS:
24.
4)
Depress and turn tooperate and lock override.
Manual override
4019
2
23.5P=19(Pitch)
2n-1/8(A, B port)
AA
BB
60.5
48.1
41.5
26
(Non-locking)Manual override
� -Q
1.3-68
Series SYJ7000
Grommet (G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
27850
39870
411890
5138110
6158130
7178150
8198170
9218190
10238210
11258230
12278250
13298270
14318290
15338310
16358330
17378350
18398370
19418390
20438410
StationL1
L2
0.8
141.
8
127.
2
95.1
≅ 30
0
(Lea
d w
ire le
ngth
)
63.1
75.5
0.8
≅ 300
(Lead wire length)
86.6
87.1
108
122.
6
41 Type Manifold: Side Ported/SS5YJ7-41- Station -01G
: ≅ 3
00H
: ≅ 6
00
(Lea
d w
ire le
ngth
)
6-1/4(P, R port)
20.5
31.5
31.5
1919
L2
L1
36 (G
Z, G
S: 3
6.7)
65.1
15.1
122
(GZ
, GS
: 123
.4)
P=20(Pitch)
22.2
(GZ,
GS:
22.
9)
1.3
2219 60 64
.3
4-ø4.5(Mounting holes)
85.2
(GZ,
GS
: 85.
9)
14
15
RP
R
RP
R
B
A A
B
A
B
A
B
A
B
Depress and turn tooperate and lock override.
Manual override
75.5
63.1
56.5
41
6.5 10.5
30.5
26.5
2n-1/8(A, B port)
Manual override(Non-locking)
P=20(Pitch)
A
B
A
B
� -Q
1.3-69
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Grommet(G), (H)
L plug connector (L) M plug connector (M)
∗ Other dimensions are the same as the grommet style. ∗ Other dimensions are the same as the grommet style.
27749
39668
411587
5134106
6153125
7172144
8191163
9210182
10229201
11248220
12267239
13286258
14305277
15324296
16343315
17362334
18381353
19400372
20419391
StationL1
L2
G: ≅
300
H: ≅
600
(Lea
d w
ire le
ngth
)
6-1/4(P, R porrt)
19
32.5
31.5
C8:
Max
.6.5
C6:
Max
.6
18.5
18
19
32.5
0.8
141.
8
127.
2
95.1
≅ 30
0
(Lea
d w
ire le
ngth
)
64.1
76.5
0.8
70.5
19
32.5
≅ 300(Lead wire length)
87.6
70.5
87.1
108
122.
6
42 Type Manifold: Side Ported/SS5YJ7-42- Station -C6, C8
L2
L1
36 (G
Z ,G
S: 3
6.7)
65.1
15.1
122
(GZ
, GS
: 123
.4)
P=19(Pitch)
22.2
(GZ,
GS:
22.
9)
1.3
2219 60 64
.3
4-ø4.5(Mounting holes)
85.2
(GZ,
GS
: 85.
9)
14
15
B
A
B
A
B
A
B
A
B
A
RP
R
RP
R
Depress and turn tooperate and lock override.
Manual override
76.5
[83]
64.1
57.5
42
8
8.5
29.5
252n-One-touch fitting(A, B port) P=19
(Pitch)Applicable tube: C6: T0604 C8: T0806
A
B
A
B
(Non-locking)Manual override
� -Q
1.3-70
Series SYJ7000
Flat Cable Manifold
SS5YJ7-21P- Station
38868
4108.588.5
5129109
6149.5129.5
7170150
8190.5170.5
9211191
10231.5211.5
11252232
12272.5252.5
StationL1
L2
16.5
11.5
2121
3060
16
6-1/4(P, R port)
62.5(4.9)
2-One-touch fitting(A, B port)Applicable tube C6: T0604 C8: T0806
60.5
26 8.8
28.5Polarity indication
Applicable connector: 26-pole MIL type(Conforms to MIL-C-83503)
31.8
C6, C8(Built-in One-touch fittings)
4-ø4.5(Mounting holes)
141.
8
94.4
21
62.8
93.6
93.8
19.5
2.8
33.6
63.6
16.6
21.5
17
Triangle mark
L1
L2 10
13.5
1.51.5
(Pitch) P=20.5A Side
2n-1/8(A, B port)
RR
P
BAR
RP
BA
BA
BA
BA
B Side
Depress and turn tooperate and lock override.
Manual override
41.5
(Non-locking)Manual override
� -Q
1.3-71
SV
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQZ
VQD
VFS
VS
VS7
VQ7
Series SYJ7000
Specifications
Made to Order SpecificationsSeries SYJ3000/5000/7000
Series
Coil rated voltage (V)
Power consumption(W)
SYJ T
Inrush
Holding
12, 24DC
Specifications other than above are the same as standard models.
0.55
0.22
300050007000
Power SaverPower consumption is decreased by 1/3 by reducing the wattage required to hold the valvein an energized state.
SYJ357
T Z
56
24V DC12V DC
Rated voltage
Specify the same as standard
How to Order
Operating PrinciplesThe circuit shown below reduces currentconsumption at holding which reducesthe overall power consumption.Refer to following power wave form.
Electrical circuit (For power saver)
1:Starting current 2:Holding current
<Low Power consumption/Power wave style SYJ T>300050007000
2
Red (+)
Black (–)
Coil
Applied voltage
Standard
Power saver
62ms
Dio
de
LED
Tim
er c
ircui
t
1
24V
0V
0.55W
0.22W
0W
OrderMade
External Pilot for Body Ported Style
Operating pressure range MPa
Operating pressure range
Pilot pressure range
–100kPa to 0.7
0.15 to 0.7
Applicable solenoid valve series SYJ5�20, SYJ7�22
SYJModel No. 57 20 X20
Same as standard.
External pilot port size
Dimensions
SYJ5000: Overall length 8mm longer
SYJ7000: Overall length 8mm longer
Series
SYJ5000, SYJ7000
Port size
M5
JIS symbol
2 position double2 position single 3 position closed centre 3 position exhaust centre 3 position pressure centre
Body ported
(B)2
1(P)
5(R1)
3(R2)
X X X X X
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
(B)2
1(P)
5(R1)
3(R2)
(A)4
1.3-72