Drill Pipe

  • View
    36

  • Download
    0

Embed Size (px)

Transcript

  • Page Index

    HEVIWATE DRILLPIPE SPECIFICATION SHEETS

    3-1/2 OD, INTEGRAL HEVIWATE DRILLPIPE w/ NC38 DSTJ CONNECTIONS4 OD, WELDED HEVIWATE DRILLPIPE w/ XT39 CONNECTIONS5 OD, INTEGRAL HEVIWATE DRILLPIPE w/ NC50 DSTJ CONNECTIONS5 OD, INTEGRAL HEVIWATE DRILLPIPE w/ NC50 4-1/2"IF CONNECTIONS5-1/2 OD, WELDED HEVIWATE DRILLPIPE w/ 5-1/2"FH DSTJ CONNECTIONS5-7/8 OD, WELDED HEVIWATE DRILLPIPE w/ XT 57 CONNECTIONS

    DRILLPIPE SPECIFICATION SHEETS

    2-7/8 OD, 10.40 LBS/FT, S-135 DRILLPIPE w/ HYDRIL WT23 CONNECTIONS2-7/8 OD, 10.40 LBS/FT, S-135 DRILLPIPE w/ HYDRIL WT26 CONNECTIONS3-1/2 OD, 15.50 LBS/FT, S-135 DRILLPIPE w/ NC38 DSTJ CONNECTIONS4 OD, 14.00 LBS/FT, S-135 DRILLPIPE w/ XT39 CONNECTIONS5 OD, 19.50 LBS/FT, S-135 DRILLPIPE w/ NC50 DSTJ CONNECTIONS5-1/2 OD, 21.90 LBS/FT, S-135 DRILLPIPE w/ 5-1/2 FH DSTJ CONNECTIONS5-7/8 OD, 23.40 LBS/FT, S-135 DRILLPIPE w/ XT57 CONNECTIONS

    Page 01020304060708

    Page 101112131415

  • Saltire Energy LtdBadentoy RoadBadentoy ParkPortlethenAberdeenAB12 4YA

    VAT No. 671 1126 64EU No. EU/0908/147/08 Registered No. 165384Registered Oce: 23 Rubislaw Terrace, Aberdeen AB10 1XE

    Telephone: (01224) 872228Fax: ((01224) 897541

    E mail: enquiries@saltire-energy.com

    DRILLPIPE SPECIFICATION SHEET

    2-7/8 OD, 10.40 LBS/FT, S-135 DRILLPIPE w/ HYDRIL WT23 CONNECTIONS

    PIPE SPECIFICATION NEW PREMIUM 80% REMAINING BODY WALL

    NOMINAL PIPE OD 2-7/8 2.209 NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 10.40 AVERAGE WEIGHT (TUBE & TOOL JOINT) (LBS) 320 AVERAGE LENGTH 30.5 ADJUSTED WEIGHT (LBS/FT) 10.50 NOMINAL WALL THICKNESS 0.362 0.290 NOMINAL INSIDE DIAMETER 2.151 2.151 TYPE OF UPSET IU GRADE S-135 INTERNAL PLASTIC COATING TK-34 PIPE CAPACITIES NEW PREMIUM

    80% REMAINING BODY WALL PIPE BODY YIELD STRENGTH (LBS) 386,000 PIPE TORSIONAL YIELD (FT-LBS) 21,000 PIPE API COLLAPSE (PSI) 29,720 PIPE BURST RESISTANCE (PSI) 29,750 TOOL JOINT SPECIFICATION NEW PREMIUM

    CONNECTION HYDRIL WT23 PIN / BOX OD 3-1/8 PIN / BOX ID 1-1/2 HARDBANDING ARMACOR M TOOL JOINT TENSILE YIELD (LBS) 387,000 TOOL JOINT TORSIONAL YIELD (FT-LBS) 10,400 PIN / BOX LENGTH 12 / 10 MAKE-UP TORQUE (MINIMUM) (FT-LBS) 2,200 MAKE-UP TORQUE (MAXIMUM) (FT-LBS) 8,300 FLUID DISPLACEMENT (GAL/FT) 0.16 FLUID CAPACITY (GAL/FT) 0.18 DRIFT SIZE 1.375

    The information on this specification sheet is provided for illustration purposes only and is taken from information available from the manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

    Page 1

  • Saltire Energy LtdBadentoy RoadBadentoy ParkPortlethenAberdeenAB12 4YA

    VAT No. 671 1126 64EU No. EU/0908/147/08Registered No. 165384Registered Oce: 23 Rubislaw Terrace, Aberdeen AB10 1XE

    Telephone: (01224) 872228Fax: ((01224) 897541

    E mail: enquiries@saltire-energy.com

    DRILLPIPE SPECIFICATION SHEET

    2-7/8 OD, 10.40 LBS/FT, S-135 DRILLPIPE w/ HYDRIL WT26 CONNECTIONS

    PIPE SPECIFICATION NEW PREMIUM 80% REMAINING BODY WALL

    NOMINAL PIPE OD 2-7/8 2.209 NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 10.40 AVERAGE WEIGHT (TUBE & TOOL JOINT) (LBS) 320 AVERAGE LENGTH 30.5 ADJUSTED WEIGHT (LBS/FT) 10.50 NOMINAL WALL THICKNESS 0.362 0.290 NOMINAL INSIDE DIAMETER 2.151 2.151 TYPE OF UPSET IU GRADE S-135 INTERNAL PLASTIC COATING TK-34 PIPE CAPACITIES NEW PREMIUM

    80% REMAINING BODY WALL PIPE BODY YIELD STRENGTH (LBS) 386,000 PIPE TORSIONAL YIELD (FT-LBS) 21,000 PIPE API COLLAPSE (PSI) 29,720 PIPE BURST RESISTANCE (PSI) 29,750 TOOL JOINT SPECIFICATION NEW PREMIUM

    CONNECTION HYDRIL WT26 PIN / BOX OD 3-3/8 PIN / BOX ID 1-3/4 HARDBANDING ARNCO 200XT TOOL JOINT TENSILE YIELD (LBS) 416,000 TOOL JOINT TORSIONAL YIELD (FT-LBS) 12,300 PIN / BOX LENGTH 12 / 10 MAKE-UP TORQUE (MINIMUM) (FT-LBS) 2,800 MAKE-UP TORQUE (MAXIMUM) (FT-LBS) 9,800 FLUID DISPLACEMENT (GAL/FT) 0.16 FLUID CAPACITY (GAL/FT) 0.18 DRIFT SIZE 1.625

    The information on this specification sheet is provided for illustration purposes only and is taken from information available from the manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

    Page 2

  • Saltire Energy LtdBadentoy RoadBadentoy ParkPortlethenAberdeenAB12 4YA

    VAT No. 671 1126 64EU No. EU/0908/147/08Registered No. 165384Registered Oce: 23 Rubislaw Terrace, Aberdeen AB10 1XE

    Telephone: (01224) 872228Fax: ((01224) 897541

    E mail: enquiries@saltire-energy.com

    DRILLPIPE SPECIFICATION SHEET

    3-1/2 OD, 15.50 LBS/FT, S-135 DRILLPIPE w/ NC38 DSTJ CONNECTIONS

    PIPE SPECIFICATION NEW PREMIUM 80% REMAINING BODY WALL

    NOMINAL PIPE OD 3-1/2 3.320 NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 15.50 AVERAGE WEIGHT (TUBE & TOOL JOINT) (LBS) 535 AVERAGE LENGTH 31.5 ADJUSTED WEIGHT (LBS/FT) 16.96 NOMINAL WALL THICKNESS 0.449 0.359 NOMINAL INSIDE DIAMETER 2.602 2.602 TYPE OF UPSET EUE GRADE S-135 INTERNAL PLASTIC COATING TK-34P PIPE CAPACITIES NEW PREMIUM

    80% REMAINING BODY WALL PIPE BODY YIELD STRENGTH (LBS) 581,000 451,120 PIPE TORSIONAL YIELD (FT-LBS) 37,950 29,060 PIPE API COLLAPSE (PSI) 30,180 25,960 PIPE BURST RESISTANCE (PSI) 30,310 27,710 TOOL JOINT SPECIFICATION NEW PREMIUM

    CONNECTION NC38 DSTJ PIN / BOX OD 5 4-11/16 PIN / BOX ID 2-9/16 HARDBANDING ARNCO 300XT TOOL JOINT TENSILE YIELD (LBS) 703,300 703,250 TOOL JOINT TORSIONAL YIELD (FT-LBS) 26,940 23,390 PIN / BOX LENGTH 10.5 / 15.0 MAKE-UP TORQUE (MINIMUM) (FT-LBS) 16,200 14,000 MAKE-UP TORQUE (MAXIMUM) (FT-LBS) 18,900 16,400 FLUID DISPLACEMENT (GAL/FT) 0.259 FLUID CAPACITY (GAL/FT) 0.275 DRIFT SIZE 2-7/16

    The information on this specification sheet is provided for illustration purposes only and is taken from information available from the manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

    Page 3

  • Saltire Energy LtdBadentoy RoadBadentoy ParkPortlethenAberdeenAB12 4YA

    VAT No. 671 1126 64EU No. EU/0908/147/08Registered No. 165384Registered Oce: 23 Rubislaw Terrace, Aberdeen AB10 1XE

    Telephone: (01224) 872228Fax: ((01224) 897541

    E mail: enquiries@saltire-energy.com

    DRILLPIPE SPECIFICATION SHEET

    4 OD, 14.00 LBS/FT, S-135 DRILLPIPE w/ XT39 CONNECTIONS

    PIPE SPECIFICATION NEW PREMIUM 80% REMAINING BODY WALL

    NOMINAL PIPE OD 4 3.868 NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 14.00 AVERAGE WEIGHT (TUBE & TOOL JOINT) (LBS) 494 AVERAGE LENGTH 31.64 ADJUSTED WEIGHT (LBS/FT) 15.44 NOMINAL WALL THICKNESS 0.330 0.264 NOMINAL INSIDE DIAMETER 3.340 3.340 TYPE OF UPSET IU GRADE S-135 INTERNAL PLASTIC COATING TK-34P PIPE CAPACITIES NEW PREMIUM

    80% REMAINING BODY WALL PIPE BODY YIELD STRENGTH (LBS) 513,600 403,500 PIPE TORSIONAL YIELD (FT-LBS) 41,900 32,800 PIPE API COLLAPSE (PSI) 20,141 13,836 PIPE BURST RESISTANCE (PSI) 19,491 17,820 TOOL JOINT SPECIFICATION NEW PREMIUM

    CONNECTION XT39 PIN / BOX OD 4.875 4.594 PIN / BOX ID 2.688 HARDBANDING ARNCO 300XT TOOL JOINT TENSILE YIELD (LBS) 667,600 TOOL JOINT TORSIONAL YIELD (FT-LBS) 35,300 PIN / BOX LENGTH 10.0 / 15.0 MAKE-UP TORQUE (MINIMUM) (FT-LBS) 12,400 MAKE-UP TORQUE (MAXIMUM) (FT-LBS) 21,200 FLUID DISPLACEMENT (GAL/FT) 0.236 FLUID CAPACITY (GAL/FT) 0.436 DRIFT SIZE 2.563

    The information on this specification sheet is provided for illustration purposes only and is taken from information available from the manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

    Page 4

  • VAT

    No.

    671

    112

    6 64

    EU N

    o. E

    U/0

    908/

    147/

    08Re

    gist

    ered

    No.

    165

    384

    Salt

    ire

    Ener

    gy L

    tdBa

    dent

    oy R

    oad

    Bade

    ntoy

    Par

    kPo

    rtle

    then

    Abe

    rdee

    nA

    B12

    4YA

    Tele

    phon

    e: (0

    1224

    ) 872

    228

    Fax:

    ((01

    224)

    897

    541

    E m

    ail:

    enqu

    iries

    @sa

    ltire

    -ene

    rgy.

    com

    4.87

    5 X 2

    .68

    8 XT3

    9 Too

    l Joi

    nt W

    ear

    -5,

    0000

    5,00

    0

    10,0

    00

    15,0

    00

    20,0

    00

    25,0

    00

    30,0

    00

    35,0

    00

    40,0

    00

    4.88

    4.75

    4.63

    4.50

    4.38

    4.25

    4.13

    Tool

    Join

    t OD

    (in)

    Torsional Strength (ft-lbs)

    2.68

    8 in

    ID

    XT

    39

    80%

    4"

    14

    .00

    IU S-

    135

    Prem

    Pi

    pe

    Max

    Re

    com

    men

    ded

    Mak

    e-u

    p To

    rqu

    e

    Min

    Re

    com

    men

    ded

    Mak

    e-u

    p To

    rqu

    e

    Page 5

  • Saltire Energy LtdBadentoy RoadBadentoy ParkPortlethenAberdeenAB12 4YA

    VAT No. 671 1126 64EU No. EU/0908/147/08Registered No. 165384Registered Oce: 23 Rubislaw Terrace, Aberdeen AB10 1XE

    Tel