Drive the Next New Mini Solar Controller Features 1. Remote multi function key pad backlite LCD screen available (option) 2. Function safety compliance 3. ISO13849-1 PL-e Cat3 ISO1800-5-2 STO SIL3 4. Global standard Compliance 5. Solar Panel voltage set point calculation at every start 6. True Maximum Power Point Tracking (MPPT) function 7. Available with IP54 Certified Panel With Remote monitoring functionality for Pump Controller & integrated data logging • Server functionality is also available. RMU can work with internal Drive supply. The digital outputs can be configured freely. In order to operate the inverter it is only required (must) to give the run command (FWD or REV). P(+) N(-) L1 L2 L3 3 ~ AC Motor U V W Y1 TANK FULL CM 13 +10V PLC CMY FWD LOW SOURCE SINK 12 TANK LEVEL R1 R1 RX Tank level resistive sensor X1 TANK HL X2 TANK LL Optional (if tank level resistive sensor is not available) PV solar panel Start/Stop signal Indication signals 11 0V Q1 New Mini Solar Controller Type Name Description Comments Digital input FWD Run Command Run permission Digital input TANK HL Maximum tank level If this signal is ON inverter can not RUN Digital input TANK LL Minimum tank level To define the behaviour. Only indication. Digital output LOW POWER Low Power Indication Indicates that power is lower than expected value Digital output TANK FULL Tamk maximum level Indication Indicates that tank is at or above maximum level Digital output TANK LOW Tank low level Indication Indicates that tank is at or below minimum level Analog input TANK LEVEL Tank level signal Analog signal to indicate tank level CONTROL SIGNALS FEI/DP/Solar/032/R0

Drive the Next New Mini Solar Controller

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Drive the Next New Mini Solar Controller

Drive the NextNew Mini Solar Controller

Features1. Remote multi function key pad backlite LCD screen available (option)2. Function safety compliance3. ISO13849-1 PL-e Cat3 ISO1800-5-2 STO SIL34. Global standard Compliance5. Solar Panel voltage set point calculation at every start6. True Maximum Power Point Tracking (MPPT) function7. Available with IP54 Certified Panel

With Remote monitoring functionality for Pump Controller & integrated data logging • Server functionality is also available.• RMU can work with internal Drive supply.

• The digital outputs can be configured freely.• In order to operate the inverter it is only required (must) to

give the run command (FWD or REV).

P(+) N(-)

L1

L2

L3

3 ~AC Motor

U

V

W

Y1TANK FULLCM

13+10V

PLCCMY FWDLOW

SOURCESINK

12TANK LEVEL

R1 R1

RX

Tank level resistive sensor

X1TANK HL

X2TANK LL

Optional (if tanklevel resistive sensor is not

available)

PV solar panel

Start/Stopsignal

Indication signals

110V

Q1

New Mini Solar Controller

Type Name Description CommentsDigital input FWD Run Command Run permissionDigital input TANK HL Maximum tank level If this signal is ON inverter can not RUNDigital input TANK LL Minimum tank level To define the behaviour. Only indication.Digital output LOW POWER Low Power Indication Indicates that power is lower than expected valueDigital output TANK FULL Tamk maximum level Indication Indicates that tank is at or above maximum levelDigital output TANK LOW Tank low level Indication Indicates that tank is at or below minimum levelAnalog input TANK LEVEL Tank level signal Analog signal to indicate tank level

CONTROL SIGNALS

FEI/DP/Solar/032/R0

Page 2: Drive the Next New Mini Solar Controller

Solar Pump ControllerIndicative Technical Specification chart from MNRE:- with mentioned Fuji Electric Pump controller Part no’s

Optimal Operationg Point Calculation FunctionAt every Start the inverter determines the optimal operating point depending on current conditions.

MPPT FunctionDuring Operation is searches the working point that provides maximum power. The conditions (Mainly temperature and irradiance) will change during operation

Start Criteria by PV Panel Voltage and TimeStop Criteria Selectable by Frequency or Power At every Start / Stop the inverter determines the optimal operating point depending on current conditions.

Detection of Sudden Changes of Conditions (Especially irradiance)Detects a sudden changes in the operating conditions and changes the working point accordingly.

Dry Pump Detection FunctionDetects that the water is not reaching the pumpWater tank maximum Level DetectionIf the Tank level reaches the maximum level the pump will stop

Two Sets of PID gainsThe PID Controller has to respond rapidly or slowly depending on the operating conditions changes.

Low Power FunctionIt indicates that the output power is low.For example due to dust on the solar PV Panels.

IEC ApprovalFor rated output efficiency measurement (IEC61683) and climate test (IEC60068) as per standard.

220V : 0.1KW ~ 2.2KW440V : 0.4KW ~ 220KW

Induction &BLDC Motor

Submersible &Surface Pump

Description Model-1 Model-2 Model-3 Model-4 Model-5 Model-6 Model-7 Model-8

PV ARRAY 1200 Wp 1800 Wp 3000Wp 3000Wp 3000Wpw 4800Wp 4800Wp 4800Wp

Motorcapacity

1hp submersible pump

2hp submersible pump

3hp submersible pump

3hp submersible pump

3hp submersible pump

5hp submersible pump

5hp submersible pump

5hp submersible pump

SolarPump Controller FRN0006C2S-7SL FRN0010C2S-7SL FRN0012C2S-7SL FRN007C2S-4SL FRN0007C2S-4SL FRN0011C2S-4SL FRN0011C2S-4SL FRN0011C2S-4SL

Shut Off Dynamic Head 45 metre 45 metre 45 metre 75 metre 100 metre 70metre 100metre 150metre

Water output

38,400 litre /dayfrom a total head of

30 metre

57,600 litre /dayfrom a total head of

30 metre

96000 litre /dayfrom a total head of

30 metre

57000litre /dayfrom a total head of

30 metre

39000 litre /dayfrom a total head of

30 metre

91200 litre /dayfrom a total head of

30 metre

62400 litre /dayfrom a total head of

30 metre

40800litre /dayfrom a total head of

30 metre

High Performance Functions in Solar Pump Controller

Fuji Electric India Pvt. Ltd.409-410, Meadows, Sahara Plaza, Andheri Kurla Rd,Andheri (E), Mumbai-400059,Tel: +91-022-40104870/71E-mail: [email protected]