POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
v AC CURRENT / VOLTAGE
v WATT / VAR
v WATTHOUR / VARHOUR
v POWER FACTOR
CONTENTSCONTENTS
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
v FREQUENCY
v DC VOLTAGE / SIGNAL ISOLATOR / DC CURRENT
v RTD
v Vo, Ao(PEAK HOLDER)
v POTENTIOMETER / POWER DISTRIBUTOR
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
AC CURRENT TRANSDUCER
Ø CURRENT MODEL CODE DT- A- 1) 2) 3) 4) 5)
Ø 기능 및 특성v Accuracy : ±0.2%v Input overload : 120% continuous, 200% for 10 secondsv Input loss : 0.5VA or lessv 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)
1) CONNECTION 2) INPUT 3) OUTPUT 4) SENSING TYPE 5) AUX.POWER1 1in 1packaging(1P) A 5A (AC 0~5A) 1 DC 4~20mA A Average A AC 110/220V3 3in 1packaging(3P) B 1A (AC 0~1A) 2 DC 0~1mA B R.M.S B AC 115/230V
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
Ø CONNECTION DIAGRAM
3 3in 1packaging(3P) B 1A (AC 0~1A) 2 DC 0~1mA B R.M.S B AC 115/230V3 Specify Current(0~20mA max) C AC 120/240V4 DC 0~5V D DC 24V5 DC 1~5V E DC 48V6 DC 0~10V F DC 110V7 Specify Voltage(0~10V max) G DC 125V8 Specify Current Limit H DC 220V
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
AC VOLTAGE TRANSDUCER
Ø VOLTAGE MODEL CODE DT- V- 1) 2) 3) 4) 5)
Ø 기능 및 특성v Accuracy : ±0.2%v Input overload : 120% continuous, 150% for 10 secondsv Input loss : 0.5VA or lessv 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)
1) CONNECTION 2) INPUT 3) OUTPUT 4) SENSING TYPE 5) AUX.POWER1 1in 1packaging(1P) A AC 0~150V 1 DC 4~20mA A Average A AC 110/220V3 3in 1packaging(3P) B AC 0~259V 2 DC 0~1mA B R.M.S B AC 115/230V
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
Ø CONNECTION DIAGRAM
3 3in 1packaging(3P) B AC 0~259V 2 DC 0~1mA B R.M.S B AC 115/230VC AC 0~300V 3 Specify Current(0~20mA max) C AC 120/240VD AC 0~520V 4 DC 0~5V D DC 24V
5 DC 1~5V E DC 48V6 DC 0~10V F DC 110V7 Specify Voltage(0~10V max) G DC 125V
H DC 220V
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
WATT TRANSDUCER
Ø 기능 및 특성v ACCURACY : ±0.2%v Input overload
1) CT : 1000% for 10 seconds2) PT : 150% for 10 seconds
v Input loss/Element : 0.5VA(C), 0.3VA(V)v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
Ø 표1Ø WATT MODEL CODE DT- W- 1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER12 1Phase 2Wire 1 표1 참조 1 DC 4~20mA A AC 110/220V13 1Phase 3Wire 2 DC 0~1mA B AC 115/230V33 3Phase 3Wire 3 Specify Current(0~20mA max) C AC 120/240V34 3Phase 4Wire 4 DC 0~5V D DC 24V
5 DC 1~5V E DC 48V6 DC 0~10V F DC 110V7 Specify Voltage(0~10V max) G DC 125V8 DC 4~12~20mA(±Watt input) H DC 220V9 DC -1~0~1mA(±Watt input)
10 Current Limit – about 23mA max11 Current Limit (±Watt input) – about 23mA max
v 비표준 Cal. Watt 계산 예시1. CT비 : 2500/5A, 2. PT비 : 460/115, 3. F.S : 1500kW 일 경우- CT비 × PT비 × Cal. Watt = F.S이므로 500 × 4 × Cal.watt = 1500kW는
Cal.watt = = 750Watt 입니다.1500kW2000
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
VAR TRANSDUCER
Ø 기능 및 특성v ACCURACY : ±0.2%v Input overload
1) CT : 1000% for 10 seconds2) PT : 150% for 10 seconds
v Input loss/Element : 0.5VA(C), 0.3VA(V)v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
Ø 표1Ø VAR MODEL CODE DT- R- 1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER12 1Phase 2Wire 1 표1 참조 1 DC 4~12~20mA A AC 110/220V13 1Phase 3Wire 2 DC -1~0~1mA B AC 115/230V33 3Phase 3Wire 3 Specify Current(0~20mA max) C AC 120/240V34 3Phase 4Wire 4 DC -5~0~5V D DC 24V
5 DC 1~3~5V E DC 48V6 DC -10~0~10V F DC 110V7 Specify Voltage(±10V max) G DC 125V
H DC 220V
1) 2) 3) 4)
v 비표준 Cal. Var 계산 예시 (Var TD는 기본이 양방향임)
1. CT비 : 2500/5A, 2. PT비 : 460/115, 3. F.S : ±1500kVar 일 경우- CT비 × PT비 × Cal. Var = F.S이므로 500 × 4 × Cal.Var = 1500kVar는
Cal.watt = = ±750Var 입니다.1500kVar2000
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
WATTHOUR TRANSDUCER
Ø 기능 및 특성v ACCURACY : ±0.4%v Input overload
1) CT : 1000% for 10 seconds2) PT : 150% for 10 seconds
v Input loss/Element : 0.5VA(C), 0.3VA(V)v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER
Ø 표1Ø WATT MODEL CODE DT- WH-
1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER12 1Phase 2Wire 1 표1 참조 1 1 Watthour / 1 Pulse A AC 110/220V13 1Phase 3Wire 2 10 Watthour / 1 Pulse B AC 115/230V33 3Phase 3Wire 3 1 Watthour / 10 Pulse C AC 120/240V34 3Phase 4Wire 4 1 kWatthour / 1 Pulse D DC 24V
5 10 kWatthour / 1 Pulse E DC 48V6 100 kWatthour / 1 Pulse F DC 110V
G DC 125VH DC 220V
v Pulse 누적량 계산
= kWH/1Pulse 입니다.
예1) CT비 : 500/5A, 2. PT비 : 3300/110, 3. Cal. Watt : 1000Watt 4. Pulse : 1000P 일 경우
= 3kWH/1Pulse
예2) CT비 : 500/5A, 2. PT비 : 3300/110, 3. Cal. Watt : 1000Watt 4. Pulse : 3000P 일 경우
= 1kWH/1Pulse
CT비 × PT비 × Cal.wattPulse
100 × 30 × 10001000
100 × 30 × 1000
3000
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
VARHOUR TRANSDUCER (단방향전용)
Ø 기능 및 특성v ACCURACY : ±0.4%v Input overload
1) CT : 1000% for 10 seconds2) PT : 150% for 10 seconds
v Input loss/Element : 0.5VA(C), 0.3VA(V)v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER
Ø 표1Ø VARHOUR MODEL CODE DT- RH-
1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER12 1Phase 2Wire 1 표1 참조 1 1 Varhour / 1 Pulse A AC 110/220V13 1Phase 3Wire 2 10 Varhour / 1 Pulse B AC 115/230V33 3Phase 3Wire 3 1 Varhour / 10 Pulse C AC 120/240V34 3Phase 4Wire 4 1 kVarhourr / 1 Pulse D DC 24V
5 10 kVarhour / 1 Pulse E DC 48V6 100 kVarhour / 1 Pulse F DC 110V
G DC 125VH DC 220V
v Pulse 누적량 계산
= kVarh/1Pulse 입니다.
예1) CT비 : 500/5A, 2. PT비 : 3300/110, 3. Cal. Var : 1000Var 4. Pulse : 1000P 일 경우
= 3kVarh/1Pulse
예2) CT비 : 500/5A, 2. PT비 : 3300/110, 3. Cal. Var : 1000Var 4. Pulse : 3000P 일 경우
= 1kVarh/1Pulse
CT비 × PT비 × Cal.VarPulse
100 × 30 × 10001000
100 × 30 × 1000
3000
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
Ø CONNECTION DIAGRAM
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
POWER FACTOR TRANSDUCER
Ø 기능 및 특성
1) CONNECTION 2) INPUT 3) OUTPUT 4) AUX.POWER12 1Phase 2Wire A 110V(190/R3) / 0.5~5A 1 DC 4~12~20mA A AC110/220V
v ACCURACY : ±0.5% ±1Degreev Input overload
1) CT : 1000% for 10 seconds2) PT : 150% for 10 seconds
v Input loss/Element : 0.5VA(C), 0.3VA(V)v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
Ø POWER FACTOR MODEL CODE DT- PF- 1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
12 1Phase 2Wire A 110V(190/R3) / 0.5~5A 1 DC 4~12~20mA A AC110/220V33 3Phase 3Wire B 220V(380/R3) / 0.5~5A 2 DC 0~0.5~1mA B AC 115/230V34 3Phase 4Wire C 63.5V(110/R3) / 0.5~5A 3 Specify Current(0~20mA max) C AC 120/240V
4 DC 0~2.5~5V D DC 24V5 DC 1~3~5V E DC 48V6 DC 0~5~10V F DC 110V7 Specify Voltage(0~10V max) G DC 125V
H DC 220V
Ø CONNECTION DIAGRAM
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
FREQUENCY TRANSDUCER
Ø 기능 및 특성
1) INPUT 2) OUTPUT 3) AUX.POWERA 55~65Hz (AC 30~300V) 1 DC 4~12~20mA A AC110/220V
v Accuracy : ±0.1%v Input overload : 115% continuousv Input loss : 0.1VA or lessv 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
Ø POWER FACTOR MODEL CODE DT-F- 1) 2) 3)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
B 45~55Hz (AC 30~300V) 2 DC 0~0.5~1mA B AC 115/230V3 Specify Current(0~20mA max) C AC 120/240V4 DC 0~2.5~5V D DC 24V5 DC 1~3~5V E DC 48V6 DC 0~5~10V F DC 110V7 Specify Voltage(0~10V max) G DC 125V
H DC 220V
Ø CONNECTION DIAGRAM
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
DC VOLTAGE & MILLIVOLTAGE TRANSDUCER
Ø 기능 및 특성v ACCURACY : ±0.3%v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)v OPTION(2 O/P)
1) INPUT 2) OUTPUT 3) AUX.POWERA 0~150V 1 DC 4~20mA A AC 110/220VB 0~300V 2 DC 0~1mA B AC 115/230VC 0~1V 3 DC 0~20mA C AC 120/240V
Ø DC VOLTAGE MODEL CODE DT-DV- 1) 2) 3)
1) INPUT 2) OUTPUT 3) AUX.POWERA 0~50mV 1 DC 4~20mA A AC 110/220VB 0~100mV 2 DC 0~1mA B AC 115/230VC 0~10mV 3 DC 0~20mA C AC 120/240V
Ø DC MILLIVOLTAGE MODEL CODE DT-DMV- 1) 2) 3)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
C 0~1V 3 DC 0~20mA C AC 120/240VD 0~5V 4 Specify Current(0~20mA max) D DC 24VE 0~10V 5 DC 0~5V E DC 48VF 1~5V 6 DC 1~5V F DC 110V
G Specify voltage(0~1000V max) 7 DC 0~10V G DC 125V
8 Specify voltage(0~10V max) H DC 220V
Ø CONNECTION DIAGRAM
C 0~10mV 3 DC 0~20mA C AC 120/240VD -50~0~50mV 4 Specify Current(0~20mA max) D DC 24V
E Specify voltage(0~999mV max) 5 DC 0~5V E DC 48V
6 DC 1~5V F DC 110V7 DC 0~10V G DC 125V8 Specify voltage(0~10V max) H DC 220V
(1 O/P)
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
SIGNAL ISOLATOR & DC CURRENT
Ø 기능 및 특성v ACCURACY : ±0.3%v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)v OPTION(2 O/P)
Ø ISOLATOR MODEL CODE DT-DV- -1) 2) 3) 4)
Ø DC CURRENT MODEL CODE DT-DCA- -1) 2) 3) 4)
1) INPUT 2) OUTPUT 3) AUX.POWER 4) OPTIONA DC 4~20mA A DC 4~20mA A AC 110/220V S 1 O/PB DC 0~1mA B DC 0~1mA B AC 115/230V D 2 O/PC DC 0~10mA E DC 0~20mA C AC 120/240V
I Specify Current H Specify Current D DC 24V
1) INPUT 2) OUTPUT 3) AUX.POWER 4) OPTIONA DC 0~1A A DC 4~20mA A AC 110/220V S 1 O/PB Specify Current(0~1A max) B DC 0~1mA B AC 115/230V D 2 O/P
C DC 0~20mA C AC 120/240VD DC 1~5V D DC 24V
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
Ø CONNECTION DIAGRAM
I Specify Current H Specify Current(0~20mA max) D DC 24V
4 DC 0~10V 4 DC 0~10V E DC 48V5 DC 0~5V 5 DC 0~5V F DC 110V6 DC 1~5V 6 DC 1~5V G DC 125V
7 Specify voltage 7 Specify voltage(0~10V max) H DC 220V
D DC 1~5V D DC 24VE DC 0~5V E DC 48VF DC 0~10V F DC 110V
G DC 125VH DC 220V
(1 O/P) (2 O/P)
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
RTD TRANSDUCER
Ø 기능 및 특성v ACCURACY : ±0.3%v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)
1) INPUT (PT100Ω) 2) OUTPUT 3) AUX.POWER 4) OPTIONA 0~50 1 DC 4~20mA A AC110/220V S 1 O/PB 0~100 2 DC 0~20mA B AC 115/230V D 2 O/PC 0~150 3 DC 0~1mA C AC 120/240VD 0~200 4 Specify Current (0~20mA max) D DC 24V
Ø ISOLATOR MODEL CODE DT-DV- -1) 2) 3) 4)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
D 0~200 4 Specify Current (0~20mA max) D DC 24VJ -50~100 5 DC 0~5V E DC 48VK -50~150 6 DC 1~5V F DC 110V
7 DC 0~10V G DC 125V8 Specify voltage (0~10V max) H DC 220V
Ø CONNECTION DIAGRAM
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
Vo / Ao TRANSDUCER
Ø 기능 및 특성
1) INPUT OUTPUT AUX.POWERA AC 0~150V (110V) 1 DC 4~20mA A AC 110/220VB AC 0~259V (190V) 2 DC 0~1mA B AC 115/230VC AC 0~5A 3 Specify Current (0~20mA max) C AC 120/240V
v Accuracy : ±0.5%vInput loss : 0.5VA or lessv 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 150(W) × 75(H) ×112(D)
Ø MODEL CODE DT-Vo- 1) 2) 3)
Ø MODEL CODE DT-Ao- 1) 2) 3)
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
Ø CONNECTION DIAGRAM
C AC 0~5A 3 Specify Current (0~20mA max) C AC 120/240V4 DC 0~5V D DC 24V5 DC 1~5V E DC 48V6 DC 0~10V F DC 110V7 Specify voltage (0~10V max) G DC 125V
H DC 220V
(Ao) (Vo)
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
POTENTIOMETER / POWER DISTRIBUTOR
Ø 기능 및 특성v ACCURACY : ±0.3%v 사용 환경 조건: 온도: -10~60, 습도: 5%~95%(Non-condensing)v Wall or 35mm DIN Rail 취부v ABS Resinv SIZE : 60(W) × 75(H) ×112(D)
1) INPUT 2) OUTPUT 3) AUX.POWERA 0~500Ω 1 DC 4~20mA A AC 110/220VB 0~1KΩ 2 DC 0~1mA B AC 115/230VC 0~5KΩ 3 DC 0~20mA C AC 120/240V
Ø MODEL CODE DT-PM- 1) 2) 3)
Ø MODEL CODE DT-DB- 1) 2) 3) 4)
1) INPUT 2) OUTPUT 3) AUX.POWER 4) OPTIONA DC 24~28V 1 DC 4~20mA A AC 110/220V S 1 O/PB Specify input 2 DC 0~1mA B AC 115/230V D 2 O/P
3 DC 0~20mA C AC 120/240V
DAEJOO TD SYSTEMDAEJOO TD SYSTEM
Ø CONNECTION DIAGRAM
C 0~5KΩ 3 DC 0~20mA C AC 120/240VD 0~10KΩ 4 Specify Current (0~20mA max) D DC 24VE Specify input 5 DC 1~5V E DC 48V
6 DC 0~5V F DC 110V7 DC 0~10V G DC 125V8 Specify voltage(0~10V max) H DC 220V
(POTENTIOMETER) (POWER DISTRIBUTOR)
3 DC 0~20mA C AC 120/240V
4 Specify Current(0~20mA max) D DC 24V
5 DC 1~5V E DC 48V6 DC 0~5V F DC 110V7 DC 0~10V G DC 125V
8 Specify voltage(0~10V max) H DC 220V
POWER TRANSDUCERPOWER TRANSDUCER DT SERIESDT SERIES
DAEJOO TD SYSTEMDAEJOO TD SYSTEM