DX SYSTEM
HEAT RECOVERY, DEMAND CONTROLLED VENTILATION SYSTEM
2 AERECO – DX system
DX SYSTEMA COMPLETELY NEW HEAT RECOVERY VENTILATION RANGEBased on the large experience in demand-controlled ventilation, Aereco introduces several new innovative heat recovery ventilation systems providing room by room airflow control.
These products are dedicated to residential applications and can be either installed in false ceiling, thanks to a small thickness, or in kitchen cupboard, due to optimized dimensions.
Best energy efficiency
In terms of control strategy, DX System is composed of 4 versions starting by the most performant - “Excellence”, ensuring individual room-by-room air supply and exhaust control, down to simpler versions such as “Premium”, “Evolution” and “Reference”. It makes the range scalable and adaptable precisely to the needs of each user.
The DX System optimally uses the exhaust heat to preheat the fresh air and thus offers an energy-efficient solution, whatever the version. Moreover, the demand-controlled management enables to scientifically reduce the electrical consumption of the system. The best energy-efficiency class A+ is achieved by three versions of the DX System.
Comfort and Indoor Air Quality at their best
The DX System enhances indoor comfort by providing healthy air, at a milder temperature, preheated by the integrated heat exchanger. To feel good at home, the “Excellence” and “Premium” versions, adapt, at any time, airflows to the occupants needs in every room based on the sensor’s inputs (CO2 or presence). The demand control strategy specific to the DX System follows two main purposes: to reduce inherent noise from the heat recovery system while guaranteeing the best Indoor Air Quality. Besides, in order to maximize the filters life-time, their dimensions and filtration surface have been optimized to prevent from outdoor particles.
Touch screen or control modules for visualization, setup and diagnosis
A colour LCD touch screen, supplied with “Excellence” and “Premium” allows the occupant to view system parameters, to diagnose operation, to control setups such as automatic bypass temperature, to boost ventilation or to action a free cooling on demand. It also notifies the occupant when the filters need to be replaced. The “Evolution” and “Reference” benefit from a control module and wifi connection for setup and visualization on Smartphone.
*specific to Excellence version
AERECO – DX System 3
BRING SERENITY AND COMFORT IN YOUR HOME WITH THE NEW DX SYSTEMThe DX System is a range of smart heat recovery ventilation system that supply pollen-free and dust-free preheated fresh air to living areas, ensuring a comfortable feel-good climate. Using a smart airflow control management, the DX System offers optimal indoor air quality while limiting all inherent noises from the ventilation units. In addition to the air quality and comfort it also ensures a substantial energy saving thanks to heat recovery and accurate and automatic airflow adaptation to the occupants needs in all rooms.
Conventional heat recovery
Average airflow
Average power consumption
DX SYSTEM
How a full demand controlled airflows can reduce electrical consumption of the fans
In addition to significant energy savings on heat losses, the DX System reduces primary energy consumption by reducing fan power of the unit. The fan type used (highly efficient brushless electronic commutation motors), low pressure operation and average airflow reduction through demand controlled ventilation (50%) allow the DX System to work at an average power greatly reduced compared to that of a standard heat recovery system using one or several speeds. Power consumption is thereby reduced by more than 50%.
Filters kept clean longer = less power consumption
By reducing the average airflows (by about 50%) with an equivalent indoor air quality, the DX System reduces the rate of filters clogging, thanks to the reduce volume of air passing through the filters at any given period. Filter durability is doubled compared to traditional heat recovery systems, thereby reducing pressure drops and the power consumption of the motors.
4 AERECO – DX system
Modulation enables a significant reduction in average airflows while providing excellent air quality, with heat losses produced by ventilation lowered by half on average in comparison with a constant airflow ventilation. The heat exchanger operates with a yield of about 87% recovery (DXR efficiency: 82%; DXA efficiency: 93%). Combined, these features achieve about 92% energy savings when compared with a mechanical exhaust ventilation system at constant airflow, with the same indoor air quality.
50% savings on electrical consumption
The average airflow reduction, due to the demand control ventilation offered by the DX System, also generates important savings on electrical consumption and the impact of this on preheating and fan power (see below) is very positive, saving more than 50% electrical power in comparaison with a constant airflow heat recovery with 92% efficiency.
DYNAMIX® TECHNOLOGY : AN OUTSTANDING ENERGY PERFORMANCE THROUGHOUT THE YEARBy combining the benefits of full demand controlled airflows and heat recovery, which are the pillars of the DynamiX® technology, the DX System, in Excellence version, delivers outstanding energy performance.
MODULATION
50%savings
on the airflows
HEAT EXCHANGER
87%heat recovery
more than
92%savings on air renewal heating
+ =
50% savings on the electrical consumption
Aereco DX System heat recoveryHeat recovery 92% e�ciency
Heat losses through ventilation
Pre-heating (electrical)Fans consumption (electrical)
AERECO – DX System 5
DXR - False ceiling installation
Designed for ceiling installation within the heated space, the DXR provides a truly elegant solution for multi-apartments buildings, where available space for systems is often limited, particularly in renovation projects. Its very low thickness (26 cm) and its reduced width (65 cm) allow easy installation in ceiling spaces (for example in a corridor false ceiling).
DXA - Wall mounted application
The DXA has been specifically designed for cupboards installation. Thanks to its well-fitted dimensions, the DXA can be installed both in kitchen and in other technical rooms, wall-mounted. A creamy white metal sheet covers the front face of the the DXA which allows it to be unnoticed as a technical equipment.
DXR and DXA have been specifically designed to ensure that only one person is required to install them. Wether it is done by using an ingenious concept for the DXR or by specific handles on the side fore the DXA, both of these new products use innovative concept to simplified their installation.
Filters can be easily replaced without dismounting the unit, both on the DXR and on the DXA, by just simply removing the trapdoors.
DX SYSTEM - AS FLEXIBLE AS NEEDED, FOR RENOVATION AND NEW BUILD
SIMPLIFIED INSTALLATION AND EASY FILTERS CHANGE
Through the DX System, a completely new range of heat recovery ventilation systems has been designed by Aereco to offer you the maximal flexibility in your choice for the adequate ventilation solution.
6 AERECO – DX system
DX SYSTEM INSTALLATION LAYOUT
Main difference of Premium & Evolution DX Systems is that the exhaust airflow is still regulated individually in each room, while the supply air is modulated globally for all the dwelling.
Premium, Evolution and Reference version
Compared to the Excellence version, the Premium version does not use any hub. At least, one sensor on the supply side helps adjust the airflow.
In the Evolution version, the supply side is replicating the demand controlled extract side
The Reference version brings further simplification of the control algorithm, providing constant airflow at supply and exhaust. For more details please refer to our selection guide.
12
33
3
3
5
9
54
5
5
6
6
78
Excellence version
Airflows are automatically controlled according to the needs of each dwelling’s room. Outdoor filtered air is supplied 3 in the bedrooms and in the living room. Stale air is extracted 6 , 7 from the kitchen, bathroom and WC.
The supply airflows to all main rooms are regulated based on the inputs from one or many CO2 sensors or presence detectors 5 . On the exhaust 6 side, the airflow is adjusted, according to parameters read by various sensors (BXC): humidity in the kitchen and bathroom), and presence detector in WC.
The total supply and exhaust airflows are balanced thanks to an exhaust-controlled compensation valve 8 , installed in the bathroom or in the kitchen 7 . An additional compensation valve, integrated in the DX Hub 2 , adjusts supply compensation airflow, supplying preheated 4 fresh
air in the living room, in the kitchen or in a corridor.
Principle of operation
The DX System is comprised of a main unit 1 DXA (wall-mounted) or DXR (ceiling-mounted) connected to exhaust and supply ductworks. The counter-flow heat exchanger, integrated into the main unit, ensures the recovery and transfer of most of the energy from the exhaust air to the supply air, thus limiting the energy required to heat the fresh air.
Excellence version
Premium version
Evolution version
Reference version
1DX Unit
Heat recovery unit with balanced demand controlled airflows
1 (DXR or DXA)
DXR DXA
2DX Hub
Distribution box for demand controlled supply airflows
1 hub only for excellence
- - -
DX HUB 5 DX HUB 6
3 SDCSupply unit
1 to 6 1 to 6 1 to 6 1 to 6
4 SDCSupply unit for balance
1 - - -
5 CO2 sensors
1 to 5 at least 1 - -
5 Presence sensors(CO2 or/and
presence sensors)
6BXC
Exhaust unit with integrated humidity, presence detection or other sensors
1 to 5 1 to 5 1 to 5 -
7 BXC bExhaust unit for balance
1 1 - -
8 Exhaust compensation valve 1 1 - -
9Preheater
Galvanised steel body with built-in resistance
1 (optional)
1 (optional)
1 (optional)
1 (optional)
Touch screenDisplay and control module for the user also
used for maintenance1 1 - -
Control module / WiFi - - 1 1
Note: Some other components may be used in the system such as condensation exhaust pump, acoustic silencers, etc. See page 18 to page 19.
AERECO – DX System 7
DX System components:
VERSION EXCELLENCE PREMIUM EVOLUTION REFERENCE
Design
DXRWhite painted galavanized
steelWhite painted galavanized
steel Galvanized steel Galvanized steel
DXAEPP with optional white
metal sheet coverEPP with optional white
metal sheet coverEPP with optional white
metal sheet coverEPP with optional white
metal sheet cover
HUB5 Galvanized steel - - -
HUB6 Galvanized steel - - -
Demand controlled ventilation
@ ExhaustRoom by room demand
controlRoom by room demand
controlRoom by room demand
controlConstant exhaust airflow
@ supplyRoom by room demand
controlGlobal flow demand control
Global flow modulated to balance exhaust airflow
Constant airflow ( same that exhaust airflow)
Sensors @ supply 1 to 5 At least 1 - -
Sensors @ exhaust 1 to 5 1 to 5 1 to 5 -
Airflow
Max. Airflow 230 230 230 230
Other nominal airflows 80 / 140 / 200 80 / 140 / 200 80 / 140 / 200 80 / 140 / 200
Free-cooling Yes Yes Yes Yes
Preheating Yes (optional) Yes (optional) Yes (optional) Yes (optional)
Power consumption
Ecodesign label A+ A+ A+ A
Others
Interface Touchscreen Touchscreen Control module / WiFi Control module / WiFi
Condensation management Siphon or pump Siphon or pump Siphon or pump Siphon or pump
8 AERECO – DX system
WHICH VERSION FOR WHICH NEEDS
AERECO – DX System 9
10 AERECO – DX system
Base
Control and power supply box
Fans
Heat exchanger
Condensation receiver
Access cover
Filter G4
Filter F7
Filter trapdoors
DXR: Top efficient heat recovery unit with a top model size
With a base, a distribution box and vital parts all being made of metal, DXR wins on quality and maximum durability. Most of its components (motor, fans, and heat exchanger) are manufactured in Germany and assembled in Aereco, in France.
HIGH QUALITY MANUFACTURE
AERECO – DX System 11
DXA: So much discreet that it will go unnoticed in the technical room
The DXA is produced using mainly the EPP (Expanded Polypropylene), which is a ¨green¨, environment friendly material, 100% recyclable. It doesnot include any VOC (volatile organic compound), CFC (chlorofluorocarbon) or other compounds known to be particularly harmful to the environment. Inaddition, weighting only 16 kg, DXA has a very high resistance to weight ratio.The touchscreen interface may be integrated in the DXA unit (in its interface base ) or fixed on the wall at max 10m from the main unit.
Ductwork white metal sheet cover (optional)
Exhaust and supply galvanized ducts
Control and power supply box
Fan
Bypass
White metal sheet cover
Filter trapdoors
Interface base
Base
Filter G4
Bypass
Condensate pump / siphon
Heat exchanger
Filter F7
Condensation receiver
Base
Condensation receiver
Fan
Filter F7
Base
12 AERECO – DX system
DXA - Dimensions in mm
DXR - Dimensions in mm
140
116012
4
158
246
258
1260
140
328
328
714
650
DN160 DN16
0316
125
ø160 ø160 88
101
166
164 210
248 151 155
1189
240
R2,50
80
1184
130
545
40
482
545 138 118
151
R80
248
155
554
R80
101
AERECO – DX System 13
DX Hub 6 - Dimensions in mm
DX Hub 5 - Dimensions in mm
755
124
280
100
12920
0114
63663
6
685
695
78 134
254
340
Ø158
Ø158
695773
126685
DN75105
Ø13
200
100
DN 100 DN 100 DN 125
DN
100 11
8
100
151
DN 160
151
100
DN 160
640
546
494
433
520
31,5
21,5
DN 13
468
577
14 AERECO – DX system
DXR
Standard codeDXR1225 (Excellence / Premium)
DXR1714 (Evolution)DXR1708 (Reference)
EcodesignLabel (EU Ecodesign Directive) A+ (for Excellence, Premium, Evolution) - A (for Reference)Airflow characteristicsMax. airflow m3/h 230Other nominal airflows m3/h 80 / 140 / 200 / 230Airflow compensation (filter clogging) automaticAirflow balance (supply and exhaust) automaticAcousticsSound power level Lw @ 161 m3/h, 50 Pa dB(A) 40Certifications dB CE, EACElectricsPower supply 230 VAC, 50 HzMotor type EC (x2)Power consumption @ 161 m3/h @50 Pa W 34,2Power consumption @ 230 m3/h @50 Pa W 91,0Sensors connections RJ12 / RJ45Demand controlCompatible versions of DX System Excellence / Premium / Evolution / ReferenceMin - Max Number of sensors for modulation at supply (1 - 5) for Excellence / PremiumMin - Max Number of sensors for modulation at exhaust (1 - 5) for Excellence / PremiumSensors type at supply presence / C02
Exhaust units type humidity / presence / switch / C02 / VOCCharacteristicsExchanger aluminium / counter flow type / 82% efficiencyFilters on supply air: 1 x F7 / on exhaust air: 1 x G4Weight kg 46Colour white for Excellence / Premium - galvanized steel for Evolution / ReferenceMaterial (main) galvanised steel with phonic and thermal insulationDimensions mm with duct connectors: 260 x 650 x 1200 / without duct connectors: 260 x 650 x 1160InstallationMax. number of main rooms 6Max. number of technical rooms 5Connections 2 x (2 x ø160 mm)Installation horizontal only, to the false ceiling / 4 points of attachmentOther functionsInterface 2.8” Colour Touch Screen interface (Excellence / Premium) - Control module / WiFi (Evolution / Reference)Bypass controlled by outdoor temperature / also used for free coolingPreheating (optional) with resistance in fresh air ductwork from outsideCondensation management exhaust through lateral tube / optional condensate pumpTemperature of useInstallation room frost free: +5°C < T°< +50°CIncoming outdoor fresh air or Extract -5°C < T° < +50°C without preheating / -26°C < T° < +50°C with preheating
DXR Heat recovery unit for ceiling installation
A B C D E F G
A+A B C D E F G
A+
AERECO – DX System 15
DXA
Standard codeDXA1240 (Excellence / Premium)
DXA1712 (Evolution)DXA1705 (Reference)
DXA1247 (Excellence / Premium)DXA1711 (Evolution)DXA1706 (Reference)
EcodesignLabel (EU Ecodesign Directive) A+ (for Excellence, Premium, Evolution) - A (for Reference)Airflow characteristicsMax. airflow m3/h 230Other nominal airflows m3/h 80 / 140 / 200 / 230Airflow compensation (filter clogging) automaticAirflow balance (supply and exhaust) automaticAcousticsSound power level Lw @ 161 m3/h, 50 Pa dB(A) 52
Certifications CEElectricsPower supply 230 VAC, 50 HzMotor type EC (x2)Power consumption @ 161 m3/h @50 Pa W 36,5Power consumption @ 230 m3/h @50 Pa W 92,0Sensors connections RJ12Demand controlCompatible versions of DX System Excellence / Premium / Evolution / ReferenceMin - Max Number of sensors for modulation at supply (1 – 5) for Excellence - At least 1 for Premium - No for othersMin - Max Number of sensors for modulation at exhaust (1 - 5) for Excellence / PremiumSensors type at supply presence / C02 (Excellence / Premium)Exhaust units type humidity / presence / switch / C02 / VOC (Excellence / Premium / Evolution)CharacteristicsExchanger polystyrene / counter flow type / 93% efficiencyFilters on supply air: 2 x F7 / on exhaust air: 1 x G4Weight kg 23Colour black / Grey EPP - white painted Galvanized steel houssing (option)Material (main) expanded polypropylene (EPP) covered by a white galvanized metal sheet (optional)Dimensions mm with duct connectors: 1428 x 552 x 545 / without duct connectors: 1188 x 552 x 545InstallationMax. number of main rooms 6Max. number of technical rooms 5Connections 2 x (2 x ø160 mm)Installation 2 wall fixed railsOther functions (in option)Interface 2.8” Colour Touch Screen interface (Excellence / Premium) - Control module / WiFi (Evolution / Reference)Bypass controlled by outdoor temperature / also used for free coolingPreheating (optional) with resistance in fresh air ductwork from outsideCondensation management condensate pump exhaust through siphonTemperature of useInstallation room frost free: +5°C < T°< +50°CIncoming outdoor fresh air or Extract -5°C < T° < +50°C without preheating / -26°C < T° < +50°C with preheating
DXA Heat recovery unit for wall installation
A B C D E F G
A+A B C D E F G
A+
16 AERECO – DX system
0 50 100 150 200 2500
50
100
150
200
250
300
350
a bc d
Pressure in Pa
Airflow in m3/h
80 m3/h140 m3/h
200 m3/h230 m3/h
DXR Unit maximal airflow setting :
a = 40 dBb = 43 dB
c = 46 dBd = 49 dB
Sound power level Lwa
0 50 100 150 200 2500
50
100
150
200
250
300
350
ab
c d
Pressure in Pa
Airflow in m3/h
80 m3/h140 m3/h
200 m3/h230 m3/h
a = 40 dBb = 43 dB
c = 46 dBd = 49 dB
80 m3/h140 m3/h
200 m3/h230 m3/h
DXA Unit maximal airflow setting :
a = 49 dBb = 54 dB
c = 59 dBd = 60 dB
Sound power level Lwa
0 50 100 150 200 2500
10
20
30
40
50
60
70
80
90
100
Power in W
Airflow in m3/h
80 m3/h140 m3/h
200 m3/h230 m3/h
DXR Unit maximal airflow setting :
0 50 100 150 200 2500
10
20
30
40
50
60
70
80
90
100
Power in W
Airflow in m3/h
80 m3/h140 m3/h
200 m3/h230 m3/h
DXA Unit maximal airflow setting :
DXR - Airflow characteristics
DXA - Airflow characteristics
AERECO – DX System 17
Standard code HUB1288
Airflow characteristics
Pressure at supply Pa 25
Acoustics
Phonic enveloppe
Phonic silencers -
Electrics
Electrical connections (sensors) 5 x RJ12
Characteristics
Weight kg 10,9
Dimension mm 592 x 490 x 206
Colour metal
Material (main) galvanised steel with phonic and thermal insulation
Inlet duct connections (to DXR or DXA) choice among 2 x ø160 mm
Outlet duct connections (to the supply units) 5 x ø100 mm + 1 x ø125 mm
Installation
Installation horizontal or vertical
Installation room frost free: +5°C < T°< +50°C
Standard code HUB1434
Airflow characteristics
Pressure at supply Pa 65
Acoustics
Phonic enveloppe
Phonic silencers
Electrics
Electrical connections (sensors) 5 x RJ12
Characteristics
Weight kg 18
Dimension mm 695 x 684 x 199
Colour metal
Material (main) galvanised steel with phonic and thermal insulation and acoustic silencers
Inlet duct connections (to DXR or DXA) choice among 3 x ø160 mm
Outlet duct connections (to the supply units) 6 x ø75 mm
Installation
Installation horizontal or vertical
Installation room frost free: +5°C < T°< +50°C
DX HUB 6 Active air supply distribution box
DX HUB 5 Active air supply distribution box
standard
standard
18 AERECO – DX system
DXR Heat recovery unit for ceiling installation Excellence / Premium
DXR 230
Code
Exhaust compensation
valve
Code
Exhaust compensation
unit
Code
Exhaustunit
Code
Supplyunit
Code
DXR1225 ADX1224 BFX114 BXCxxx SDC1107
+ Quantity Quantity Quantity Quantity Quantity
SiphonX1 X1 X1
1 / main room
up to 5
1 / main room
up to 6
Preheater
Code
x1 F7x1 G4
Filter kit
Code
Condensatepump
Code
Fixing suspension
system
Code
ADX1098 ADX1254 ADX1099 ADX1106
Acousticsilencer
RJ45 cable
Code
RJ12 cable
Code
5 m : ADX119710 m : ADX1123
5 m : ADX124910 m : ADX125020 m : ADX125130 m : ADX1252
DX HUB 5
Code
Supply compensation
unit
Code
Wallinterface
Code
HUB1288 SDC1108 IHM1293
Quantity Quantity Quantity
X1 X1 X1
Wallinterface
Code
CO2sensor
Code
Presencesensor
Code
IHM1195 CAP1100 CAP1101
Quantity Quantity
X1 at least 1, up to 5
CO2sensor
Code
Presencesensor
Code
CAP1100 CAP1101
Quantity
at least 1, up to 5
DX HUB 6
Code
Wallinterface
Code
HUB1434 IHM1362
Quantity Quantity
X1 X1
CO2sensor
Code
²
Presencesensor
Code
CAP1100 CAP1101
Quantity
at least 1, up to 5
PREM
IUM
VER
SIO
N:
GLO
BAL
DCV
HRV
BASI
C IT
EMS
EXCE
LLEN
CE V
ERSI
ON
:FU
LL D
CV H
RVAC
CESS
ORI
ES
OR
AERECO – DX System 19
DXR Heat recovery unit for ceiling installation Evolution / Reference
DXR
Code
Supplyunit
Code
DXR1708 SDC1107
+ Quantity Quantity
SiphonX1
1 / main room
up to 6
Preheater
Code
x1 F7x1 G4
Filter kit
Code
Condensatepump
Code
Fixing suspension
system
Code
ADX1098 ADX1254 ADX1099 ADX1106
Acousticsilencer
RJ45 cable
Code
5 m : ADX119710 m : ADX112320 m : ADX171530 m : ADX1716
SmartInterface
Code
IHM1707
10 m
A m
ax5V
DC
OUT
1
OUT
2
IN 2
IN 1
0 Vo
lt
2I2O
MOD
ULE
Power ON
Modbus tra�c
Modbus connection
Module2I2O
Code
ADX1673
BASI
C IT
EMS
REF
REN
CE
Preheater
Code
x1 F7x1 G4
Filter kit
Code
Condensatepump
Code
Fixing suspension
system
Code
ADX1098 ADX1254 ADX1099 ADX1106
Acousticsilencer
RJ45 cable
Code
5 m : ADX119710 m : ADX112320 m : ADX171530 m : ADX1716
SmartInterface
Code
IHM1707
10 m
A m
ax5V
DC
OUT
1
OUT
2
IN 2
IN 1
0 Vo
lt
2I2O
MOD
ULE
Power ON
Modbus tra�c
Modbus connection
Module2I2O
Code
ADX1673
BASI
C IT
EMS
EVO
LUTI
ON
DXR 230
Code
Exhaustunit
Code
Supplyunit
Code
DXR1714 BXCxxx SDC1107
+ Quantity Quantity Quantity
SiphonX1
1 / main room
up to 5
1 / main room
up to 6
20 AERECO – DX system
Excellence / PremiumDXA Heat recovery unit for wall installation
DXA230
Code
DXA1240
+ Quantity
Condensatepump
X1
DXA230
Code
DXA1247
+ Quantity
SiphonX1
Exhaust compensation
valve
Code
Exhaust compensation
unit
Code
Exhaustunit
Code
Supplyunit
Code
ADX1224 BFX114 BXCxxx SDC1107
Quantity Quantity Quantity Quantity
X1 X11 / main
roomup to 5
1 / main room
up to 6
Wallinterface
Code
IHM1439
Quantity
X1
Built-ininterface
Code
IHM1438
Quantity
X1
CO2sensor
Code
Presencesensor
Code
CAP1100 CAP1101
Quantity
at least 1, up to 5
OR
OR
Wallinterface
Code
IHM1295
Quantity
X1
Built-ininterface
Code
IHM1294
Quantity
X1
Wallinterface
Code
IHM1441
Quantity
X1
Built-ininterface
Code
IHM1440
Quantity
X1
PREM
IUM
VER
SIO
N:
GLO
BAL
DCV
HRV
BASI
C IT
EMS
DX HUB 5
Code
Supply compensation
unit
Code
HUB1288 SDC1108
Quantity Quantity
X1 X1
DX HUB 6
Code
HUB1434
Quantity
X1
CO2sensor
Code
Presencesensor
Code
CAP1100 CAP1101
Quantity
at least 1, up to 5
EXCE
LLEN
CE V
ERSI
ON
:FU
LL D
CV H
RV
OR
OR
OR
Preheater
Code
ADX1098
x2 F7x1 G4
Filter kit
Code
ADX1428
Upper designcover
Code
ADX1449
RJ45 cable
Code
5 m : ADX119710 m : ADX1123
RJ12 cable
Code5 m : ADX124910 m : ADX125020 m : ADX125130 m : ADX1252
ACCE
SSO
RIES
Acousticsilencer
Metal white front cover
for IHM 1438IHM 1294IHM 1440
Code
ADX1448
Metal white front cover
for IHM 1439IHM 1295IHM 1441
Code
ADX1555
AERECO – DX System 21
Evolution / ReferenceDXA Heat recovery unit for wall installation
DXA230
Code
DXA1705
+ Quantity
Condensatepump
X1
DXA230
Code
DXA1706
+ Quantity
SiphonX1
Supplyunit
Code
SDC1107
Quantity
1 / main room
up to 6
OR
BASI
C IT
EMS
Preheater
Code
x2 F7x1 G4
Filter kit
Code
Metal whitefront cover
Code
ADX1098 ADX1428 ADX1555
Acousticsilencer
RJ45 cable
Code
5 m : ADX119710 m : ADX112320 m : ADX171530 m : ADX1716
SmartInterface
Code
IHM1707
10 m
A m
ax5V
DC
OUT
1
OUT
2
IN 2
IN 1
0 Vo
lt
2I2O
MOD
ULE
Power ON
Modbus tra�c
Modbus connection
Module2I2O
Code
ADX1673
REFE
REN
CE
DXA230
Code
DXA1712
+ Quantity
Condensatepump
X1
DXA230
Code
DXA1711
+ Quantity
SiphonX1
OR
BASI
C IT
EMS
Exhaustunit
Code
Supplyunit
Code
BXCxxx SDC1107
Quantity Quantity
1 / main room
up to 5
1 / main room
up to 6
Preheater
Code
x2 F7x1 G4
Filter kit
Code
Metal whitefront cover
Code
ADX1098 ADX1428 ADX1555
Acousticsilencer
RJ45 cable
Code
5 m : ADX119710 m : ADX112320 m : ADX171530 m : ADX1716
SmartInterface
Code
IHM1707
10 m
A m
ax5V
DC
OUT
1
OUT
2
IN 2
IN 1
0 Vo
lt
2I2O
MOD
ULE
Power ON
Modbus tra�c
Modbus connection
Module2I2O
Code
ADX1673
EVO
LUTI
ON
22 AERECO – DX system
Notes:
AERECO – DX System 23
Notes:
FLY6
51GB
_v9
– Co
pyrig
ht A
erec
o –
Imag
es: A
erec
o, F
otol
ia –
All
data
and
pict
ures
in th
is do
cum
ent a
re n
on c
ontra
ctua
l and
are
sub
ject
to c
hang
e wi
thou
t prio
r not
ice.
Aereco S.A.62 rue de Lamirault – Collégien – 77615 MARNE LA VALLEE CEDEX 3 – FRANCE – tel. +33 1 60 06 26 63 – fax +33 1 64 80 47 26
www.aereco.com