2
TORK 57 USA 800.321.5847 www.nsiindustries.com DIGITAL CONTROLS APPLICATIONS ORDERING INFO FEATURES E & E-PB SERIES MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 24 HOUR TIME SWITCH Signs Air conditioning Lighting Sump pumps Ventilating fans SCHEDULING: 20 ON/OFF set points repeat each day Minimum setting 1 minute DAYLIGHT SAVING: Automatic adjustment (can be omitted) LEAP YEAR: Automatic Compensation MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes CLOCK FORMAT: AM/PM POWER OUTAGE BACKUP: Permanent schedule retention Supercapacitor provides 4 days of real time backup MOMENTARY OPTION: For mechanically held contractors: Model E201B only Configure with simple jumper change for single-channel momentary operation CATALOG NO. UPC CODE INPUT SUPPLY (VAC) 50/60Hz NO. OF CHANNELS OUTPUT DRY CONTACTS E101B 82401 120-277 1 SPST E103B 82411 120-277 1 DPST E120B 82406 120-277 1 SPDT E201B 82466 120-277 2 SPST E101PB 82461 120 1 SPST BACK-UP WITHOUT BATTERY, ECO FRIENDLY!

E & E-PB SERIES - W. W. GraingerE-PB 120VAC, 50/60Hz . TERMINAL RANGE: #8 - #16AWG . OPERATING TEMPERATURE:-40° to +149°F (-40° to +65°C) . POWER CONSUMPTION: 6VA Max . ENCLOSURE:

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E & E-PB SERIES - W. W. GraingerE-PB 120VAC, 50/60Hz . TERMINAL RANGE: #8 - #16AWG . OPERATING TEMPERATURE:-40° to +149°F (-40° to +65°C) . POWER CONSUMPTION: 6VA Max . ENCLOSURE:

TORK 57

A DIVISION OF NSi INDUSTRIES, LLCUSA • 800.321.5847 • www.nsiindustries.com

DIGITALCONTROLS

APPLICATIONS

ORDERING INFO

FEATURES

E & E-PB SERIESMULTIPURPOSE CONTROLS1 OR 2 CHANNEL24 HOUR TIME SWITCH

SignsAir conditioningLightingSump pumpsVentilating fans

SCHEDULING: 20 ON/OFF set points repeat each day . Minimum setting 1 minute .

DAYLIGHT SAVING: Automatic adjustment (can be omitted) .

LEAP YEAR: Automatic Compensation .

MANUAL OVERRIDE: Until the nextregularly scheduled ON or OFF, automaticoperation then resumes .

CLOCK FORMAT: AM/PM .

POWER OUTAGE BACKUP: Permanentschedule retention . Supercapacitor provides 4 days of real time backup .

MOMENTARY OPTION: For mechanically held contractors: Model E201B only . Configure with simple jumper change for single-channel momentary operation .

CATALOG NO.

UPCCODE

INPUT SUPPLY(VAC) 50/60Hz

NO. OF CHANNELS

OUTPUTDRY CONTACTS

E101B 82401 120-277 1 SPST

E103B 82411 120-277 1 DPST

E120B 82406 120-277 1 SPDT

E201B 82466 120-277 2 SPST

E101PB 82461 120 1 SPST

BACK-UP WITHOUT BATTERY, ECO FRIENDLY!

Page 2: E & E-PB SERIES - W. W. GraingerE-PB 120VAC, 50/60Hz . TERMINAL RANGE: #8 - #16AWG . OPERATING TEMPERATURE:-40° to +149°F (-40° to +65°C) . POWER CONSUMPTION: 6VA Max . ENCLOSURE:

WIRING DIAGRAMS

DPST

TIMERSUPPLY

TIMERSUPPLY

3

3 5 6

SPST

4

LOAD

120/277VAC

120/277VAC

120/277VAC

4

3 4 5

SPDT

E120B

E201B

E103B

E101B

1 2

NL N

L LN

TIMERSUPPLY

1 2

1 2

LOAD

N

L N

LOAD LOAD

N N

LOAD

N

TIMERSUPPLY

120/277VAC

E201B ONLY: UNIT MUSTBE CONFIGURED FOR MOMENTARY OPTION.

3 4 5

CH 1 SPST

CH 2 SPST

1 2

L N

LOAD

N

6LOAD

N

3

DPST

4

LOAD208 OR 240VAC

1 2

L1 L2

TIMERSUPPLY

65

3

MOMENTARY CONFIGURATION

4

120/277VAC

1 2

L N PULSE ON

CH 1

PULSE OFF

TIMERSUPPLY

65

LDPST

TIMERSUPPLY

TIMERSUPPLY

3

3 5 6

SPST

4

LOAD

120/277VAC

120/277VAC

120/277VAC

4

3 4 5

SPDT

E120B

E201B

E103B

E101B

1 2

NL N

L LN

TIMERSUPPLY

1 2

1 2

LOAD

N

L N

LOAD LOAD

N N

LOAD

N

TIMERSUPPLY

120/277VAC

E201B ONLY: UNIT MUSTBE CONFIGURED FOR MOMENTARY OPTION.

3 4 5

CH 1 SPST

CH 2 SPST

1 2

L N

LOAD

N

6LOAD

N

3

DPST

4

LOAD208 OR 240VAC

1 2

L1 L2

TIMERSUPPLY

65

3

MOMENTARY CONFIGURATION

4

120/277VAC

1 2

L N PULSE ON

CH 1

PULSE OFF

TIMERSUPPLY

65

L

DPST

TIMERSUPPLY

TIMERSUPPLY

3

3 5 6

SPST

4

LOAD

120/277VAC

120/277VAC

120/277VAC

4

3 4 5

SPDT

E120B

E201B

E103B

E101B

1 2

NL N

L LN

TIMERSUPPLY

1 2

1 2

LOAD

N

L N

LOAD LOAD

N N

LOAD

N

TIMERSUPPLY

120/277VAC

E201B ONLY: UNIT MUSTBE CONFIGURED FOR MOMENTARY OPTION.

3 4 5

CH 1 SPST

CH 2 SPST

1 2

L N

LOAD

N

6LOAD

N

3

DPST

4

LOAD208 OR 240VAC

1 2

L1 L2

TIMERSUPPLY

65

3

MOMENTARY CONFIGURATION

4

120/277VAC

1 2

L N PULSE ON

CH 1

PULSE OFF

TIMERSUPPLY

65

L

DPST TIMERSUPPLY

TIMERSUPPLY

3 3 5 6

SPST

4

LOAD

120VAC 120VAC120VAC

4 3 4 5

SPDTE120PBE103PBE101PB

1 2

NL N L LN

TIMERSUPPLY

1 2 1 2

LOAD

NL N

LOAD LOAD

N N

LOAD

N

TORK 58

CONTACT RATINGSSPECIFICATIONS

TIMING ACCURACY: Line Frequency .

INPUT VOLTAGE: E SERIES120 - 277VAC, 50/60Hz (automatic detection) .E-PB120VAC, 50/60Hz .

TERMINAL RANGE: #8 - #16AWG .

OPERATING TEMPERATURE:-40° to +149°F (-40° to +65°C) .

POWER CONSUMPTION: 6VA Max .

ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R is standard with lockable hasp (see page 153 for enclosure dimensions) .

TYPEE101B, E103B, E201B E120B E101PB

VOLTAGE RATING RATING VOLTAGE RATINGNO NO NC NO

General Purpose 120-277VAC 40A 30A 30A 120/240VAC277VAC

30A12A

Inductive 120-277VAC 40A 30A 30A 120/240VAC277VAC

30A12A

Ballast120VAC 30A 30A 10A 120VAC 20A

208-277VAC 20A 20A 10A 277VAC 6A

Tungsten 120VAC 15A 15A 2A 120VAC 5A

Pilot Duty 120-277VAC 720VA 720VA 720VA 120-277VAC 470VA

Motor120VAC 1HP 1HP 1HP 120VAC 1HP208VAC 11⁄2HP 11⁄2HP 11⁄2HP 240VAC 2HP

240-277VAC 2HP 2HP 2HP

Resistive 28VDC 30A 30A 30A 28VDC 20A

DPST

TIMERSUPPLY

TIMERSUPPLY

3

3 5 6

SPST

4

LOAD

120/277VAC

120/277VAC

120/277VAC

4

3 4 5

SPDT

E120B

E201B

E103B

E101B

1 2

NL N

L LN

TIMERSUPPLY

1 2

1 2

LOAD

N

L N

LOAD LOAD

N N

LOAD

N

TIMERSUPPLY

120/277VAC

E201B ONLY: UNIT MUSTBE CONFIGURED FOR MOMENTARY OPTION.

3 4 5

CH 1 SPST

CH 2 SPST

1 2

L N

LOAD

N

6LOAD

N

3

DPST

4

LOAD208 OR 240VAC

1 2

L1 L2

TIMERSUPPLY

65

3

MOMENTARY CONFIGURATION

4

120/277VAC

1 2

L N PULSE ON

CH 1

PULSE OFF

TIMERSUPPLY

65

L

SPECIFICATION WRITER’S GUIDEE100B only – 1 . Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT contacts, model E120B) . 2 . Unit shall be capable of 20 set points . 3 . Unit shall repeat the same schedule each day . 4 . (Model E201B ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary 5 . Unit shall have automatic Daylight Savings Time and Leap Year compensation . 6 . Unit shall program in AM/PM format . 7 . Unit shall have LCD display . 8 . Unit shall have permanent schedule retention . 9 . Unit real time clock shall be retained by super capacitor for 100 hours in a power failure . 10 . Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently . 11 . Unit shall have a NEMA 3R Indoor/Outdoor plastic enclosure . 12 . Unit shall have Load Status indication . 13 . Unit shall have Power Failure indication . 14 . To order specify TORK Model E101B (E103B) (E120B) (E201B) .