12
UK 2737 V(0)a Issue Date: Valid Until: Reference No: 15 October 2014 14 October 2024 T1128/0213 Signatory: for G Stones Chief Executive 0135 National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7252 | Fax +44 (0)20 8943 7270 | Web www.bis.uk/nmo NMO is an Executive Agency of the Department for Business Innovation & Skills NAWI Rev. 2 01 April 2011 EC Type Approval Certificate UK 2737 Revision 9 Issued by the: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-Automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC Type-Approval Certificate has been issued to: Avery Berkel Foundry Lane Smethwick West Midlands B66 2LP United Kingdom In respect of a class III Non-Automatic Weighing Instrument designated the Avery Berkel M 2 1xx series and having the following characteristics: 3 kg Maximum capacity 30 kg e 1 g n 6000 for Class III instruments with single interval n 3000 for Class III instruments per partial weighing range, with a maximum of two partial weighing ranges The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. This revision replaces previous versions of the certificate.

EC Type Approval Certificate UK 2737 Revision 9

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EC Type Approval Certificate UK 2737 Revision 9

UK 2737

V(0)a

Issue Date: Valid Until: Reference No:

15 October 2014 14 October 2024 T1128/0213

Signatory: for

G Stones Chief Executive

0135

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7252 | Fax +44 (0)20 8943 7270 | Web www.bis.uk/nmo

NMO is an Executive Agency of the Department for Business Innovation & Skills

NAWI Rev. 2 01 April 2011

EC Type Approval Certificate UK 2737 Revision 9

Issued by the:

National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Non-Automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC Type-Approval Certificate has been issued to:

Avery Berkel Foundry Lane Smethwick West Midlands B66 2LP United Kingdom

In respect of a class III Non-Automatic Weighing Instrument designated the Avery Berkel M2 1xx series and having the following characteristics:

3 kg Maximum capacity 30 kg

e 1 g

n 6000 for Class III instruments with single interval

n 3000 for Class III instruments per partial weighing range, with a maximum of two partial weighing ranges

The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

This revision replaces previous versions of the certificate.

Page 2: EC Type Approval Certificate UK 2737 Revision 9

2/12

Descriptive Annex

1 NAME AND TYPE OF INSTRUMENT

The Avery Berkel M2 1xx series Non-Automatic Weighing Instruments are mains-powered, Class III, price-computing, stand-alone instruments intended for use in the presence of a purchaser. The “xx” defines any minor product variation. Maximum capacities are from 3 kg to 30 kg.

2 DESCRIPTION

2.1 Construction (Figure 1)

2.1.1 Mechanical

Main features:

Vendor’s keyboard having 24 fixed keys and up to 40 programmable keys.

Vendor’s display having four numeric fields, one alphanumeric field, and several annunciators. A typical layout is shown in Figure 2.

Customer’s display. The layout and legends are identical to the vendor’s display.

Diecast chassis and plastic housing.

Stainless steel load receptor having four pillars fitting through holes in housing.

2.1.2 Load cell

The load cell is an Avery T103.

2.1.3 Circuit boards

The main PCB is mounted horizontally, above the power supply unit, which is in a metal box. The two displays each have their own PCB.

2.2 Operation

2.2.1 Switch-on

At switch-on, the instrument performs a self-test during which all the relevant segments of both displays are lit. The instrument attempts to set zero provided that it is within a range of 20% of its capacity.

2.2.2 Zero-tracking

Zero-tracking operates provided that the instrument is within a range of 4% of its capacity.

Page 3: EC Type Approval Certificate UK 2737 Revision 9

3/12

2.2.3 Semi-automatic zero setting

The zero button operates provided that the instrument is within a range of 4% of its capacity.

2.2.4 Automatic zero setting

Automatic zero setting operates only when the instrument has been stable below zero for at least 5 seconds.

2.2.5 Over-and under- range

If the load is less than gross zero, then the weight and price-to-pay indications are inhibited and replaced by a series of bars using the lower display segments.

If the load is more than nine divisions above the maximum capacity, then the weight and price-to-pay indications are inhibited and replaced by a series of bars using the upper display segments.

2.2.6 Tare

Semi-automatic subtractive tare balancing or tare weighing can be performed, dependent upon configuration. The maximum tare is equal to capacity.

Preset tares may be associated with PLU (Price Look-Up) files, or may be keyboard assigned in which case the instrument is set up with a subtractive tare weighing device. The maximum tare is equal to capacity (single interval versions only) or the limit of the first partial weighing range (multi-interval versions).

2.3 Software

The software version numbers for the instrument are shown on the ‘test report’ printout which may be obtained by double pressing the ‘test button’ and shall be as follows:

"772C11M series BOOT va.x.x " "773C11M series APP vb.x.x"

(where “a” maybe 3, 4, 5, 6, or 7, “b” may also be 3, 4, 5, 6, or 7, and "x" reflects minor, non-legally relevant software changes).

3 TECHNICAL DATA

3.1 Technical characteristics

3.1.1 Power supply 110 - 240 V AC. 50/60 Hz.

4 PERIPHERAL DEVICES AND INTERFACES

4.1 Interfaces

Having a combination of any of the three available interface types: Ethernet, RS232 and a cash drawer.

Page 4: EC Type Approval Certificate UK 2737 Revision 9

4/12

4.2 Peripheral devices

The following peripheral devices may be connected to the interfaces provided:

Peripheral devices that have been issued with a EC Test Certificate by a Notified Body responsible for Type Approval under Directive 2009/23/EC; or

Peripheral devices without a EC Test Certificate under the following conditions:

- it bears the CE marking for conformity to the EMC Directive;

- it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation;

- it prints weighing results and other data as received from the weighing instrument without any modification or further processing;

- it complies with the applicable requirements of EN45501, i.e. 4.2, 4.4, 4.6 and 4.7.

A printing device may print additional information such as date or number to identify the printed weighing result(s) or sets of weighing results.

5 APPROVAL CONDITIONS

This certificate is issued subject to the following conditions:

5.1 Legends

5.1.1 The instrument bears the following legends:

Max Min e = Class III

5.1.2 The instrument shall bear the following legends:

Accuracy class CE marking Green M Serial number Manufacturer’s mark or name Certificate number

The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the Directive 2009/23/EC.

Page 5: EC Type Approval Certificate UK 2737 Revision 9

5/12

6 LOCATION OF SEALS AND VERIFICATION MARKS

6.1 The data plate is located on the left-hand side of the instrument as seen by the vendor. It is secured, either by sealing or by being of a form such that it is destroyed when removed.

6.2 Components that may not be dismantled or adjusted by the user must be secured by a suitable mark placed over the securing screws of the cabinet. The securing mark may be either:

a mark of the manufacturer and/or manufacturer’s representative, or

an official mark of a verification officer.

Verification marks, and the CE marking, are located on, or adjacent to, the data plate.

7 ALTERNATIVES

7.1 Having the M2 2xx series, which has the addition of a tower mounted single or double sided LCD display.

7.2 Having the M2 3xx series, which has the addition of a tower mounted self service keyboard and customer display only.

7.3 Having the M2 4xx series, utilising a two-piece construction shown in Figure 3.

7.4 Having the M2 410, utilising a construction as shown in Figure 4.

7.5 Having the M2 420, which incorporates two printers, utilising a construction as shown in Figure 5.

7.6 Having an R.F. Radio LAN communications card internally fitted.

7.7 Having the M2 5xx series, utilising a hanging scale construction as shown in Figure 6.

7.8 Having the M2 series incorporating a touch screen on the vendors display for selection of PLU and function keys as shown in Figure 7. (M2 3xx and M2 5xx series excluded).

7.9 Having the M2 601 / 603, utilizing a construction as shown in Figure 9. The M2 603 variant may be integrated into a manual or Auto Wrapper system.

7.10 Having the M2 601 / 603 connected to any other remote bottom works, which incorporates a T103 load cell.

The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, “Guide for Load cells”.

Page 6: EC Type Approval Certificate UK 2737 Revision 9

6/12

7.11 Having the M2 601 / 603 connected to any other remote bottom works, which incorporates a T110 load cell.

The maximum capacity of this combination is between 30 kg and 300 kg with no more than 3000 digital scale intervals.

The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, “Guide for Load cells”.

7.12 Having the M2 601 / 603 connected to any other remote bottom works, which incorporates a T109 load cell, with the following capacities:

Single interval instrument

6 kg < Max capacity < 30 kg

n < 3000e

Multi interval instrument

15 kg < Max capacity < 30 kg

n < 3000e per partial weighing range, with a maximum of two partial weighing ranges.

The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, “Guide for Load cells”.

7.13 Having the manufacturer designated Avery Weigh-Tronix.

7.14 Having the M 2 651, utilising a construction as shown in Figure 10, connected to a remote bottom work incorporating an Avery Berkel T103, T109 or T110 load cell with the following characteristics:

Load cell Instrument capacity and verification scale interval

T103 3 kg ≤ Max ≤ 30 kg ; e ≥ 1 g n ≤ 6000 (single range) n ≤ 3000 (per partial weighing range, max of two partial weighing ranges)

T109 Single interval: 6kg Max 30kg ; e 2g

n 3000 (single range).

Multi-interval: 15kg Max 30kg ; e 5g ;

n 3000 (per partial weighing range, max of two partial weighing ranges )

T110 30kg Max 300kg ; e 10g

n 3000 (single range)

The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, "Guide for Load cells". The instrument may be integrated into a manual or Automatic Wrapper system.

Page 7: EC Type Approval Certificate UK 2737 Revision 9

7/12

7.15 Having the instrument configured for self-service operation, in which case the semi-automatic zero-setting and semi-automatic tare devices are not available to the user (disabled keys). The product designation shall be printed, when the instrument is used to sell different products, if a receipt/label is produced for the customer.

Access to the software information described in section 2.3 requires, in the self service configuration, the intervention of the owner to activate normally disabled function keys. The method of performing this is described in the user manual.

8 ILLUSTRATIONS

Figure 1 The instrument Figure 2 Typical keyboard and vendor’s display legends Figure 3 M2 4xx series Figure 4 M2 410 series Figure 5 M2 420 Figure 6 M2 5xx series Figure 7 Touch screen keyboard and vendors display legends showing typical

PLU screen Figure 8 Touch screen keyboard and vendors display legends showing primary

indications Figure 9 M2 6xx series Figure 10 M2 651

CERTIFICATE HISTORY

Issue № Date Description

UK 2737 12 October 2004 Type approval first issued.

UK 2737 Revision 1 29 April 2005 Revision 1 issued, creation of Sections 7.7 and 7.8.

UK 2737 Revision 2 8 December 2005 Revision 2 issued, creation of Sections 7.9 to 7.12.

UK 2737 Revision 3 08 May 2008 Revision 3 issued, creation of Section 2.2.6 – Tare descriptions corrected and company name changed from Avery Weigh-Tronix Ltd to Avery Berkel.

UK 2737 Revision 4 21 May 2009 Revision 4 issued, creation of Section 7.14.

UK 2737 Revision 5 10 March 2011 Authorised alternative 7.15 added.

UK 2737 Revision 6 13 September 2012 2nd paragraph added to section 7.15.

UK 2737 Revision 7 28 December 2012 Section 2.3 modified (complete software information now included).

UK 2737 Revision 8 19 March 2014 Section 2.3 modified to include older software versions. Sections 4.2 and 5.1.2 added.

UK 2737 Revision 9 15 October 2014 Certificate renewed for a further 10 years.

Page 8: EC Type Approval Certificate UK 2737 Revision 9

8/12

Figure 1 The instrument

Figure 2 Typical keyboard and vendor’s display legends

Page 9: EC Type Approval Certificate UK 2737 Revision 9

9/12

Figure 3 M2 4xx series

Figure 4 M2 410

Page 10: EC Type Approval Certificate UK 2737 Revision 9

10/12

Figure 5 M2 420

Figure 6 M2 5xx series

Page 11: EC Type Approval Certificate UK 2737 Revision 9

11/12

Figure 7 Touch screen keyboard and vendors display legends showing typical PLU

screen

Figure 8 Touch screen keyboard and vendors display legends showing primary

indications

Page 12: EC Type Approval Certificate UK 2737 Revision 9

12/12

Figure 9 M2 6xx series

Figure 10 M2 651

© Crown Copyright 2014 NATIONAL MEASUREMENT OFFICE Department for Business, Innovation & Skills