18
Eco ICID LIT DOC/CP3/63 March 2014 UPDATED RANGE includes new Stove Pipe and Accessories Eco ICID Twin Wall Insulated System Chimney designed for Stove Applications Eco ICID LIT DOC/CP3/63 SAP Issue 2 June 2014 Part of the BRAAS MONIER BUILDING GROUP

Eco icid brochure

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Eco icid brochure

Eco ICID LIT DOC/CP3/63 March 2014

UPDATEDRANGEincludes new

Stove Pipe andAccessories

Eco ICIDTwin Wall Insulated System Chimneydesigned for Stove Applications

Eco ICID LIT DOC/CP3/63 SAP Issue 2 June 2014 Part of the BRAAS MONIER BUILDING GROUP

Page 2: Eco icid brochure

2

Product DescriptionEco ICID is a Twin Wall Insulated System Chimney designed specifically for use on open or closed stoves with continuous operating temperatures of up to 450°C.

The system is designed so that the outer case is load bearing and the inner liner is free to expand independently, therefore thermal expansion is accommodated within each and every joint of the system.

Available in two versions with a choice of either a bright annealed or a matt black painted stainless steel outer case, Eco ICID is available in the following range of diameters:- 125, 150, 180 and 200mm.

• Manufactured under a Quality Management Scheme approved to BS EN ISO 9001: 2008• 4 Hour Fire Rating to BS476 Part 20• Certified for corrosion resistance on gas, oil and solid fuel by Gastec, MPA and TÜV• HETAS listed for use on solid fuel applications.

Eco ICID is CE Certified to EN1856-1 TÜV 0036 CPD 9195 010 with designations:Eco ICID is CE Certified to EN1856-2 TÜV 0036 CPD 9195 042 with designations:

Approvals

Joint DesignTwist-lock bayonet jointing system. Secured by locking band.

Advanced corrosion resistant design and construction uses laser welded 316L stainless steel inner liner and stainless steel case.

The 25mm of high density rockwool insulation maintains flue gas temperature, maximising efficiency, improving flue draught on start up and minimising condensation.

Low external case temperature.

The inner liner is free to expand through the female collar, allowing for maximum thermal expansion even during a soot fire.

The inner liner has an inward bead at the female end which acts as a capillary break preventing moisture being drawn through the joint.

FuelFiring TempShort Firing TempThermal ShockMode of OperationPressure CapabilitiesFire RatingOuter Case (Standard)Outer Case (Option)Outer Case ThicknessSeamLinerLiner Thickness (mm)SeamInsulationInsulation ThicknessAverage ThermalResistance (200°C)

Wood, solid fuel450° C550° C1000° CZero & negative pressure40Pa4 Hour Fire Rating to BS 476 Part 20Stainless SteelPainted matt black0.5mmLaser or inert gas welded316L : 1.4404 : X2CrNiMo 17-12-20.5mmLaser or inert gas weldedHigh performance mineral fibre25mm0.4m2 k/W

The chimney size should be as recommended by the appliance manufacturer. Where there is a requirement for a flue diameter smaller than the appliance spigot, then the operational requirements of the appliance and the configuration of the flue must satisfy the flue sizing requirements of EN13384-1 for single appliances, and EN13384-2 for multi appliances.

CHIMNEY DIAMETER

CORROSION RESISTANCEChimneys are subject to significant corrosion attack by flue gas condensates, particularly from solid fuel. Eco ICID is specifically designed and manufactured to resist this corrosion.

Tecnical Data

Connecting Flue PipeEN 1856-2

System ChimneyEN 1856-1

T450 N1 W V2 L50050 G60T450 N1 D V3 L50050 G60

60mm Distance to combustiblesin a combustible shaft*

T450 N1 W V2 L50050 G50T450 N1 D V3 L50050 G50

50mm Distance to combustibles in a non combustible shaft or in free air*

T450 N1 D V2 L50050 G100 M

* For full information refer to p.16 and p.17

Page 3: Eco icid brochure

3

Typical Installations

INTERNAL HOUSECombustible Floors

INTERNAL BUNGALOW(VENTILATED LOFT SPACE)Combustible and Non-Combustible floors

INTERNAL HOUSENon Combustible Floors

EXTERNALSystem Chimney

Raincap (without mesh)

Angled Flashing

Roof Support

Ventilated Firestop Plate

Ventilated Support PlateCombustible floor

Ventilated Firestop PlateCombustible floor Plate

SW-DW Stove Pipe Starter Section

Prima Smooth Connecting Flue Pipe

Combustible shaft

Protective wire mesh(required in loft space)

Taper Terminal

Storm Collar

Uni-flash

Roof Support

Firestop Plate

Support PlateNon combustible floor

Firestop PlateNon combustible floor

Adjustable Pipe

Anchor Plate

Non combustible shaft

Protective wire mesh(required in loft space)

Taper Terminal

Structural Wall Band

Structural Wall Band

Structural Wall Band Extension

45˚ Bend

Adjustable Top Plate

Cantilever Support

135˚ Tee

Mitred Wall Sleeve 45˚

Raincap (with sparkguard)

Angled Flashing

Roof Support

Prima Smooth Connecting Flue Pipe

Protective wire mesh(required in loft space)

Round BungalowFirestop Kit (unventilated)

SW-DW Stove Pipe Starter Section

Page 4: Eco icid brochure

127

Int Ø

4

DimensionsThe dimensions of the flue are:

FinishPaint - Eco ICID can be supplied painted in any RAL colour (additional costs apply)

(all article codes are for plain stainless steel versions, for black painted codes refer to product ordering paragraph above)Starting Components

Int Ø mmExt Ø mm

125180

150200

180235

200256

A

Int Ø

B

C

A

Int Ø

3530

Int Ø

100

Int Ø

100

Appliance Connector (Open) DN8A047

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125307

125308

150200

126082

126079

180235

126827

126825

200256

127410

COA

Appliance Connector (Closed) DN8A144

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125287

125288

150200

126060

126059

180235

126810

COA

200256

127393

COA

Uninsulated Increasing Adaptor DN8A143

Int ØmmExt Ømm ASAP Code Plain

SAP Code Black

12518098

125320

COA

150200123

125321

125319

180235148 COA

COA

200256178COA

COA

Insulated Increasing Adaptor DN8A136

Int ØmmExt ØmmABCSAP Code Plain

SAP Code Black

125180989849

125305

COA

15020012311352

126077

126078

18023514811352

126824

COA

20025617811352

127408

COA

Adaptor Prima Plus to Eco ICID S027

Int ØmmExt ØmmASAP Code Plain

125180130

125688

150200150

126278

180235180

126967

200256200

127575

Adaptor Prima Smooth to Eco ICID PS027

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

109992

109991

150200

110270

110268

180235

126981

126980

200256

127588

127587

COA : Code on application

127

Int Ø

A

Page 5: Eco icid brochure

Int ØmmExt ØmmSAP Code Plain

180235

126860

Adaptor Eco ICID to TecnoFlex Plus DN8A079

125180

125354

150200

126132

200256

127443

9042

C Ø

A

B

Anchor Plate DN8A0D6

Int ØmmExt ØmmABCSAP Code Plain

125180300280123

125300

150200320300148

126072

180235355335178

126774

200256375356198

127344

SW-DW Stove Pipe Starter Section1023mm Effective Length DN8A152

Int ØmmExt Ømm ASAP Code Plain

SAP Code Black

125180123

125344

125347

150200148

126124

126125

180235178

126854

126855

200256198

127439

COA

SW-DW Stove Pipe Starter Section473mm Effective Length DN8A149

Int ØmmExt Ømm ASAP Code Plain

SAP Code Black

125180123

125349

125346

150200148

126126

126123

180235- -

-

200256

--

-A Ø

473

40

A Ø

1023

40

5

COA : Code on application

100

A Adaptor Eco ICID to Prima Plus DN8A133

Int ØmmExt ØmmASAP Code Plain

125180130

125292

150200150

126062

180235180

126813

200256200

127396

A Ø

1018

40

A Ø

473

100

SW-DW Adjustable Starter Section DN8A159

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

125180125

125394

125339

150200150

126300

126117

180235180

126989

126849

200256200

127593

127434

Increasing SW-DW Stove Pipe Starter Section DN8A153

Int ØmmExt Ømm ASAP Code Plain

SAP Code Black

125180

--

-

150200123

125345

125348

180235--

-

200256

--

-

Page 6: Eco icid brochure

Pipes

Eff.

leng

thEf

f. le

ngth

Eff.

leng

thEf

f. le

ngth

Eff.

leng

thEf

f. le

ngth

4040

4040

4040

6

1460mm Effective Length DN8A128

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125253

125251

150200

126019

126017

180235

126780

126778

200256

127350

COA

960mm Effective Length DN8A001

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125285

125286

150200

126058

126056

180235

126808

126809

200256

127392

127388

750mm Effective Length DN8A157

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125273

125274

150200

126045

126046

180235

126797

126798

200256

127380

127379

460mm Effective Length DN8A002

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125269

125270

150200

126039

126037

180235

126793

126794

200256

127376

127372

293mm Effective Length DN8A003

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125261

125262

150200

126030

126028

180235

126786

COA

200256

127362

127358

160mm Effective Length DN8A004

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125258

125259

150200

126025

126023

180235

126784

COA

200256

127357

COA

Eff.

Adj

ustm

ent

Adjustable Pipe 50-230mm 1 Piece - DN8A009

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125298

125294

150200

126071

126064

180235

126819

126815

200256

127402

COA

Eff.

Adj

ustm

ent

Telescopic Pipe 215-310mm 2 Piece - DN8A151

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125295

COA

150200

126066

126068

180235

126816

COA

200256

127399

COA

Telescopic Pipe 350-570mm 2 Piece - DN8A150

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125297

COA

150200

126069

126065

180235

126818

COA

200256

127401

127398

Eff.

Adj

ustm

ent

COA : Code on application

Page 7: Eco icid brochure

7

Ext Ø

108

Int Ø

A

B

C

D

Supplied as standard with all components with a female collar

Locking Band DN8A083

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125330

125331

150200

126106

126107

180235

126842 COA

200256

127426

COA

Structural Locking Band DN8A092

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

125317

125318

150200

126092

126093

180235

126835

COA

200256

127419

COA

Inspection Length DN8A011

Int ØmmExt ØmmABCDSAP Code Plain

SAP Code Black

12518046095260230

125323

COA

15020046095260230

126099

126097

18023546095260230

126837

COA

20025646095260230

127421

COA

Tees

Int Ø

AB

C

Int Ø

A

B

B

90˚ Tee including Tee Cap DN8A135

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180246127

125282

125283

150200329162

126054

126055

180235354175

126805

COA

200256394195

127387

COA

135˚ Tee including Tee Cap DN8A137

Int ØmmExt ØmmABCSAP Code Plain

SAP Code Black

125180336259259

125249

125250

150200365283283

126015

126016

180235414326326

126777

COA

200256444351351

127347

131796

COA : Code on application

A

Tee Plug with Drain DN8A138

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

12518075

125312

COA

15020077

126088

126089

18023573

126831

COA

20025678

127415

COA

Draught Stabiliser Section DN8A026

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180COA

COA

150200COA

COA

180235

126833

COA

200256

127417

COA

Page 8: Eco icid brochure

8

A

B

15˚ Bend DN8A018

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

1251806355

125256

125254

1502006356

126022

126020

1802356356

126782

COA

2002566457

127353

COA

30˚ Bend DN8A019

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

1251806657

125264

COA

1502007061

126033

126031

1802357364

126788

COA

2002567768

127366

COA

45˚ Bend DN8A017

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

1251807970

125267

125265

1502008374

126036

126034

1802359182

126791

126789

2002569586

127371

127367

90˚ Bend DN8A015

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180146137

125277

125275

150200156147

126049

126047

180235174165

126800

COA

200256184175

127382

COA

90˚ Inspection Bend DN8A0A2

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180184139

125280

COA

150200194149

126052

COA

180235209164

126803

COA

200256219174

127385

COA

A

B

A

B

A

B

A

B

Bends

COA : Code on application

Page 9: Eco icid brochure

9

B

A

B

A

Effe

ctive

Pip

e

B

Effe

ctive

Pip

eA

Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe

ABABABABABAB

1251801642408115927995622567615051510638772

1502001644409116127995822567815051710738872

1802351644409116127995822567815051710738872

2002561648409116528096222568215052110739273

15˚ Bend offset with Standard Pipe Length

Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe

ABABABABABAB

12518014947921061542879437628292483208368142

15020015097961076546894441643296498212383146

18023515207991087549905444654299509215394149

20025615358031102553920448669303524219409153

30˚ Bend offset with Standard Pipe Length

A

B

A

B

A

B

Offsets (made by assembling 2 bends)15˚ Offset

Int ØmmExt Ømm AB

12518023231

15020023431

18023523431

20025623831

30˚ Offset

Int ØmmExt ØmmAB

12518023062

15020024466

18023525669

20025627173

45˚ Offset

Int ØmmExt ØmmAB

125180254105

150200268111

180235295122

200256309128

Offsets for 135˚ Tee and 45˚ Bend

Int ØmmExt Ømm AB

125180389310

150200425334

180235497376

200256532402

Typical Offsets (made by assembling 2 bends and a standard pipe section)

Page 10: Eco icid brochure

10

B

A

Effec

tive P

ipe

Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe

ABABABABABAB

12518012871138933784785636580431462313367218

15020013001143947790798641593436475318381224

18023513281151974801826653621448503330408235

20025613411160988807839658634453516335422241

45˚ Bend offset with Standard Pipe Length

Firestop Components

BA

BA

Round Ventilated Firestop Plate- Combustible Floor

Int ØmmExt ØABSAP Code Plain

SAP Code Black

SAP Code White

125180183380

126661

126659

126660

150200203400

127227

127225

127226

180235241430

128117

128115

128116

200256259450

128601

128599

128600

1 Piece - 9423*

* Codes and Finish Options Plain Galvanised Steel 9423P0 + Ext Ø Black RAL 9005 Matt 9423B0 + Ext Ø White RAL 9016 Matt 9423W0 + Ext Ø

** One piece firestop available for use exclusively with stove starter pipe

Round Ventilated Firestop Plate- Combustible Floor

Int ØmmExt ØABSAP Code Plain

SAP Code Black

SAP Code White

125180183380

126664

126662

126663

150200203400

127230

127228

127229

180235241430

128120

128118

128119

200256259450

128604

128602

128603

2 Piece - 9424*

* Codes and Finish Options Plain Galvanised Steel 9424P0 + Ext Ø Black RAL 9005 Matt 9424B0 + Ext Ø White RAL 9016 Matt 9424W0 + Ext Ø

Magnetic Firestop Cover Plate Kit 9509

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

SAP Code White

125180183380

126945

126946

126947

150200203400

127552

127553

127554

180235241430

128127

128128

128129

200256259450

128611

128612

128613

BA

Tees (contd.)

Page 11: Eco icid brochure

11

Bungalow Firestop Kits

BC

A

BC

A

Ventilated Support Plate - Combustible Floor 2 Piece - 95260

Int ØmmExt ØmmABCSAP Code Plain

125180183380190

126667

150200203400200

127234

180235241430215

128124

200256259450225

128607

Rectangular Ventilated Firestop Plate- Combustible Floor 2 Piece - 94250

Int ØmmExt ØmmABCSAP Code Plain

125180183380190

126666

150200203400200

127232

180235241430215

128122

200256259450225

128606

B

A

A

AB

Firestop Plate- Non Combustible Floor 94670

Int ØmmExt ØmmABSAP Code Plain

125180450280

126624

150200450300

127200

180235450338

128099

200256610356

128584

Support Plate- Non Combustible Floor 95680

Int ØmmExt ØmmABSAP Code Plain

125180330280

126646

150200350300

127210

180235450338

128107

200256406356

128591

Bungalow Round Firestop Plate- Unventilated

Int ØmmExt ØABSAP Code Plain

SAP Code Black

SAP Code White

125180183380

126526

126528

126529

150200203400

127108

127110

127111

180235241430

128084

128086

128087

200256259450

128571

128572

128573

1 Piece - 9428*

* Codes and Finish OptionsPlain Galvanised Steel 9428P0 + Ext ØBlack Ral 9005 Matt 9428B0 + Ext ØWhite Ral 9016 Matt 9428W0 + Ext Ø

B

A

Page 12: Eco icid brochure

Bungalow Firestop Kits (contd.)

B

A

B

A

12

These unventilated fire stop plates may only be used on a combustible ceiling in a bungalow where there is a minimum 60mm distance to combustibles where the chimney penetrates the ceiling area and where the roof space above the ceiling is open and ventilated. Within the roof space, a protective wire mesh framework must be built around the chimney to ensure the minimum 60mm distance to combustibles is maintained.

* Codes and Finish OptionsPlain Galvanised Steel 9430P0 + Ext ØBlack Ral 9005 Matt 9430B0 + Ext ØWhite Ral 9016 Matt 9430W0 + Ext Ø

Bungalow Square Firestop Plate- Unventilated 1 Piece - 9430*

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

SAP Code Black

125180183380

127015

127016

COA

150200203400

127619

127620

COA

180235241430COA

COA

COA

200256259450COA

COA

128614

BD C

E

A

Top Plate DN8A0D3

Int ØmmExt ØmmABCDESAP Code Plain

SAP Code Black

125180276280240160140

125140

COA

150200296300260180150

125833

125834

180235334335298210168

126572

COA

200256352356316230178

127151

COA

Wall Support Side Plates DN8A0D2

Int ØmmExt ØmmBCDESAP Code Plain

SAP Code Black

125180275160470100

125357

125355

150200295180470100

126136

126133

180235325210470100

126862

COA

200256345230470100

127445

COA

B

D

C

E

Bungalow Round Firestop Plate- Unventilated

Int ØmmExt ØABSAP Code Plain

SAP Code Black

SAP Code White

125180183380

126527

131122

COA

150200203400

127109

127106

127107

180235241430

128085

COA

COA

200256259450

131123

COA

COA

2 Piece - 9429*

* Codes and Finish OptionsPlain Galvanised Steel 9429P0 + Ext ØBlack Ral 9005 Matt 9429B0 + Ext ØWhite Ral 9016 Matt 9429W0 + Ext Ø

Support Components

COA : Code on application

Page 13: Eco icid brochure

13

Cantilever Support

Type 325 - 95420001Type 475 - 95420002

TypeInt Ømm RangeABSAP Code Plain

SAP Code Black

325125 - 150

325242

101742

130686

475125 - 200

475242

101743

130687

Used in combination with Adjustable Top Plate.

Cantilever Support

Type 570 - 95420003

TypeInt Ømm RangeABSAP Code Plain

SAP Code Black

570125 - 200

570330

101744

130688

Used in combination with Adjustable Top Plate.

Ceiling Joist Support Arms (Pair) 9459001

TypeInt Ømm RangeABSAP Code Plain

570125 - 200

39700

130694

Used in combination with Ceiling Joist Support.

B

A

B

A

50

BA

Wall Band (60mm) 92930

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180180140

126648

126620

150200200150

127213

127196

180235238168

128110

128095

200256256178

128594

128580

A

Adjustable Back Bracketfor Wall Band 60-300mm

95950

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

125180112

126623

126622

150200132

127199

127198

180235162

128098

128097

200256186

128583

128582

Structural Wall Band (50mm) 95430

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

12518015055

101265

126654

15020017055

101266

127218

18023520055

128112

COA

20025622055

128596

COA

B

A

Structural Wall Band Extension

W1 - 95440001L1 - 95440004L2 - 95440005

TypeAdj.A B C SAP Code Plain

SAP Code Black

W155 - 100

13036-

101735

130824

L1100 - 250

300-

32101738

130825

L2100 - 440

450-

32101739

130826

AB

A

C

Type W1

Types L1, L2

Ceiling Joist Support 94590

Int ØmmExt ØmmASAP Code Plain

125180321

126669

150200341

127238

180238379

128125

200256397

128609

COA : Code on application

A A

700

39

Page 14: Eco icid brochure

14

Support Components (contd.)

A

A

BA

330

330

B

A

* Codes and Finish OptionsPlain BA Stainless Steel 9580P0 + Ext Ø Black Painted RAL 9005 Matt 9580B0 + Ext Ø

1 Piece Trim Collar 90˚ 9580*

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180184330

127038

127039

150200204350

127642

127643

180235242388

128133

128134

200256260406

128618

128619

* Codes and Finish OptionsPlain BA Stainless Steel 9599P0 + Ext Ø Black Painted RAL 9005 Matt 9599B0 + Ext Ø

2 Piece Trim Collar 90˚ 9599*

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

125180184330

127040

127041

150200204350

127644

127645

180235242388COA

COA

200256260406

COA

COA

Roof Support 94640

Int ØmmExt ØmmSAP Code Plain

125180

100962

150200

100963

180235

128126

200256

128610

Guy Wire Bracket 95900

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

100641

131808

150200

100642

127202

180235

128101

COA

200256

128586

COA

Wall Sleeve 90˚

Int ØmmExt ØmmA Masonry

A Timber F

SAP Code Masonry

SAP Code Timber F

125180230300

126642

126647

150200250320

127206

127212

180235288358

COA128108

200256306376

COA128592

Masonry - 94980Timber Frame - 94810

Supplied as a 1m long mitred tube to be cut to length on site

Wall Sleeve 45˚

Int ØmmExt ØmmA Masonry

A Timber F

SAP Code Masonry

SAP Code Timber F

125180230300

126641

126643

150200250320

127205

127207

180235288358

128102

128103

200256306376

128587

128588

Masonry - 94620 Timber Frame - 94910

COA : Code on application

Page 15: Eco icid brochure

15

BD

A C

B

D

A C

* Codes and Finish OptionsPlain BA Stainless Steel 9589P0 + Ext Ø Black Painted RAL 9005 Matt 9589B0 + Ext ØWhite Painted RAL 9016 Matt 9589W0 + Ext Ø

1 Piece Trim Collar 45˚ 9589*

Int ØmmExt ØmmABCDSAP Code Plain

SAP Code Black

SAP Code White

125180184259330454

126612

126613

126614

150200204287350483

127186

127187

127188

180235242341388536

128089

128090

128091

200256260366406562

128575

128576

128577

* Codes and Finish OptionsPlain BA Stainless Steel 9579P0 + Ext Ø Black Painted RAL 9005 Matt 9579B0 + Ext ØWhite Painted RAL 9016 Matt 9579W0 + Ext Ø

2 Piece Trim Collar 45˚ 9579*

Int ØmmExt ØmmABCDSAP Code Plain

SAP Code Black

SAP Code White

125180184130330227

127035

127036

127037

150200204144350242

127639

127640

127641

180235242171388268

128130

128131

128132

200256260183406281

128615

128616

128617

Flashings

AA

150

Angled Flashing Kit 5˚- 45˚ 95510

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

125180610

126621

COA

150200700

127197

130662

180235700

128088

COA

200256800

128574

COA

Flat Flashing Kit 95530

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

125180610

126625

COA

150200610

127201

131807

180235610

128100

COA

200256610

128585

COA

150

A A

Storm Collar 95560

Int ØmmExt ØmmSAP Code Plain

SAP Code Black

125180

106140

126645

150200

106141

127209

180235

128106

128105

200256

128590

COA

Uniflash

Product CodeExt ØmmASAP Code

9454000180 - 100

500112198

94540002150 - 300

685112197

94540003250 - 450

800114341

Universal EPDM rubber/aluminium flashing. Just pull the required diameter tab on the rubber seal.

50

A A

COA : Code on application

Page 16: Eco icid brochure

Terminals

Distance to Combustibles (see p.17)

A

A

B

60mm

60mm

INTERNAL HOUSECombustible Floors

Fig. 1 Fig. 2

60mm

INTERNAL BUNGALOW(VENTILATED LOFT SPACE)Combustible and Non-Combustible Floors

Raincap with10mm sparkguard DN8A145

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

12518026690

125336

COA

15020026690

126112

COA

180235362217

126846

COA

200256362220

127430

COA

Raincap with 25mm anti-bird mesh DN8A140

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

12518026690

125337

125335

15020026690

126113

126115

180235362217

126847

126845

200256362220

127431

127432

Raincap without mesh DN8A142

Int ØmmExt ØmmABSAP Code Plain

SAP Code Black

12518026690

125144

125145

15020026690

125837

125839

180235362217

126574

126575

200256362220

127153

COA

Insulated Tapered Terminal DN8A038

Int ØmmExt ØmmASAP Code Plain

SAP Code Black

125180200

125351

125352

150200200

126130

126129

180235204

126857

126858

200256240

127441

COA

COA : Code on application

16

Page 17: Eco icid brochure

17

InstallationThese notes should be read in conjunction with the detailed Eco ICID Installation Instructions.

MANDATORY REQUIREMENTSConnection to an appliance that is connected to the fuel supply must be carried out by a GAS SAFE (gas) or OFTEC (oil) registered installer. We recommend the use of HETAS approved installers for solid fuel applications. For full design and installation details the key referral documents are:

• BS EN 1856-1: Chimneys - System Chimney Products• BS EN 1859: Metal Chimneys - Testing Methods• BS EN 1443: Chimneys - General Requirements• BS EN 15287-1: Chimneys. Design, installation and commissioning of chimneys. Chimneys for non-roomsealed heating appliances.• BS 5440-1: Fluing and ventilation for gas appliances of rated input not exceeding 70kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys.• Approved Document J: - Combustion appliances and fuel storage systems (England & Wales)• DFP Technical Booklet L: - Combustion appliances and fuel storage systems (NI)• Technical Handbook (Domestic & Non Domestic), Section 3 - Environment (Scotland)• Appliance Installation Instructions and related standards.

Other standards covering specific applications will also be relevant and must be adhered to.

Planning permission may be required, and reference should be made to the local Building Control Department.

ENCLOSURE/SHAFTSWith the exception of the room containing the appliance, where the chimney passes through any part of the building, where there is a risk of accidental human contact, i.e a bedroom etc., or where there is a risk of contact with combustible materials stored in a cupboard or in the roof-space, the chimney must be enclosed in an appropriate way to meet Building Regulations. This can be achieved by boxing in the chimney in habitable rooms, or by the use of a protective wire mesh frame in roof spaces etc. In all cases the minimum distance to any combustible material, including loft insulation, must be respected according to the table on p.2, and any enclosure should be ventilated using the appropriate ventilated fire stops (see p.7).

DISTANCE TO COMBUSTIBLES In accordance with building regulations its is essential that the correct distance to combustible material is maintained. On solid fuel applications, where there is a risk of soot fire, a distance of 60mm to combustibles must be maintained within a combustible floor and within a combustible shaft (see Fig.1 p.10). There is no need to line the area within the floor cavity with plasterboard; however the ventilated fire stop plate and ventilated support plate must be used.*

On gas and oil applications, a distance of 50mm to combustibles must be maintained within a combustible floor and within a combustible shaft. The ventilated fire stop plate and ventilated support plate must be used.*Where the chimney penetrates a non combustible floor and where a non combustible shaft is used, a distance of 50mm to the shaft is sufficient. In this case, non ventilated fire stops and non ventilated support plates may be used at first floor level with a ventilated fire stop being used where the chimney penetrates into the roof space.*

*On bungalow applications where the chimney runs through either a combustible or non-combustible ceiling, an unventilated bungalow fire stop plate kit can be used. Please note that an unventilated support plate can not be used above the ceiling in this case. The weight of the chimney should be supported using the roof support (see p.9). Distance to combustibles must be respected within the ceiling space (see Fig. 2 p.10) and mesh frame should be used within the loft space, which must be ventilated (see Fig. 2 p.10).

JOINTING SYSTEMAll joints in the Eco ICID chimney range, which require a locking band, are made by means of a simple twist lock jointing method. This is achieved by pushing together the male and female collars on each end of the main chimney components and twisting the components through 1/6 of a turn to lock the collars into place. t should be noted that the female collars on elbows and tees are not fluted in order to allow for these items to be positioned according to requirements on site. In all cases the joints should be held securely in place using the locking band, which is supplied with all components with a female collar.

Joints are not permitted within wall and ceiling spaces. Any flue pipe (i.e. single wall) connection to the chimney must be made in the same room as the appliance. The chimney must project at least 425mm below the ceiling. Where a chimney passes through a wall, a wall sleeve must be used to prevent damage to the chimney and the building.

CONNECTION TO APPLIANCEUse the appropriate appliance connector, sealing with fire rope and fire cement or high temperature sealant on solid fuel. The length of the inner liner can be trimmed where required to allow for thermal expansion within the appliance outlet spigot.

APPLIANCE REMOVALUse of an adjustable length immediately above the appliance enables removal of the appliance later without dismantling the full system.

INSPECTIONTo conform to Building Regulations, provisions should be made to enable a chimney to be inspected and cleaned. An inspection length or an insulated 90˚ or 135˚ Tee can form a suitable inspection point. To aid cleaning, sufficient distance should be left between changes of direction to permit the safe passage of cleaning brushes within the system. This is particularly important on solid fuel applications. It is recommended that chimneys serving solid fuel appliances be swept as frequently as necessary, but at least twice a year.

CHIMNEY DIAMETERThe chimney size should be as recommended by the appliance manufacturer and must satisfy the flue sizing requirements of EN13384-1 for single appliances, and EN13384-2 for multi appliances.

CHIMNEY ROUTEThe chimney should remain as straight as possible through its verticalrun to assist flow. Should it be necessary to offset a chimney run then the following guidelines should be adhered to: It is recommended that a vertical run of at least 600mm should be allowed immediately above the appliance prior to any change of direction. Within a system, on all fuels, there should be no more than 4 changes of direction of maximum 45˚. 90˚ Factory made bends or tees within the system may be treated as being equal to two 45˚ bends (as per Document J of the Building Regulations issued October 2010).

For a direct link to the Eco ICID Installation Instructions scan the QR code.

Scan QR code to download the Schiedel Installation App incorporating Product Warranty Registration function.

Page 18: Eco icid brochure

Schiedel Chimney SystemsCrowther EstateWashingtonTyne & Wear NE38 0AQTel. +44 (0)191 416 1150Fax. +44 (0)191 415 [email protected]

Complementary products and servicesfrom Schiedel Chimney Systems

ICSTwin Wall Insulated System Chimney for gas,oil and multi-fuel applications.

• Simple push-fi t jointing system• High effi ciency Superwool insulation blanket• Capillary break prevents moisture being drawn through the joint• 80-300mm Diameter range

PRIMA PLUSSingle Wall Stainless Steel Flue System.

• Prima Plus available 0.6mm or 1mm options for domestic multi-fuel stoves• Prima Plus for large residential & commercial condensing gas & oil appliances & chimney relining• 80-300mm Diameter range

PRIMA SMOOTHSingle Wall Stainless Steel Connecting Flue Pipe for use on wood and multi-fuel applications.

• 316L Grade stainless steel• Available in matt black or steel fi nish• Excellent aesthetics• Lightweight• 125-200mm internal diameters

DM & LINERSPumice System Chimneys, Firechests and Liners.

full details at www.schiedel.co.uk

www.youtube.com/user/SchiedelUK www.linkedin.com/company/schiedel-ukwww.linkedin.com/company/schiedel-uk

HETAS TRAININGCourses H001-H006 available. See website for course prospectus and application form downloads.

TECNOFLEX PLUSFor relining existing chimneys to take gas, oil,wood, multi-fuel appliances and open fi res.

• Twin skin TecnoFlex Plus available in 316L or 904L options for oil, wood, multi-fuel & open fi res• 80-300mm Diameter range

ABSOLUT XPERTThe world’s 1st Passivhaus certifi ed chimney system.

• GW3 rated - condensate resistant after a chimney fi re

• Safe connection to room sealed appliances passes blower door test with no additional rendering of the blocks