8
[email protected] www.ecococon.lt Ltd. Ecococon detailed structural views STRAW PANELS

ECOcocon_A4_12-EN

Embed Size (px)

DESCRIPTION

arquitectura de casa eco amigable

Citation preview

Page 1: ECOcocon_A4_12-EN

[email protected] www.ecococon.lt Ltd. Ecococon

detailed structural views

straw panels

Page 2: ECOcocon_A4_12-EN

wall - insulated roof detailed view

TilesTimber 50x50, interval dependant on tile specs.

Timber 50x25Breather membrane

Truss 200x50, spacing 600 insolated gapsTimber 50x50, spacing 600 insolated gaps

Reflective membraneTimber 25x50

Decking

180

30

100

Timber 50x100 l=300Timber 25x50 l=800

Timber 100x100

Timber beam 200x50 along the perimeterTimber joint

CardboardFloor joist 150x100, spacing 600

Floor decking- planks 25x100

Timber 50x100

[email protected] www.ecococon.lt Ltd. Ecococon

Page 3: ECOcocon_A4_12-EN

TilesTimber 50x50 spacing dependant on tile spec.Timber 50x25Breather membraneTruss 200x50, spacing 600

Timber 50x25 spacing 600

Timber beam 200x50spacing 600, insulated gaps

Cardboard

Timber 100x50spacing 600, insulated gaps

600

367

100

200

Plasterboard, single layer

Flooir decking 25x100

Timber beam fastening

Timber beam 200x50 along the perimeter

Thermo - reflective membrane

Timber 50x100 l=300

Timber 100x100

30

100

Timber 50x100

[email protected] www.ecococon.lt Ltd. Ecococon

insulated slab/wall/roof detailed view

Page 4: ECOcocon_A4_12-EN

curtain wall detailed view

PlasterGypsum board 2xTimber 150x50Gypsum board 2xPlaster

Plank 45x150 as curtain wall baseWaterproofing layer

Floor deckingConcrete d=130 mmPolisterene M150 d=200mmCompacted sand

Reinforced concreted=210 mm. 12A111Polisterene M150 d=200mmCompacted sand

[email protected] www.ecococon.lt Ltd. Ecococon

Page 5: ECOcocon_A4_12-EN

foundation detailed view

PlasterRendering 30mmStraw panel 400mmClay rendering d=30-50mmPlaster

Floor deckingConcrete d=130 mmPolisterene M150 d=200mmCompacted sand

Waterproof membraneReinforced concreted=210 mm. 12A111Polisterene M150 d=200mmCompacted sand

2

1

4

5

1. Pole d=300 l~10001m interval, concrete c20/252. Reinforced something200x600 concrete c20/25Reinforced structure 12A1113. Wood fiber insulation,reinforcement mixture, rendering.4. Planks 45x95 under structure5. Waterproofing layer6. Steel U profile

3

6

[email protected] www.ecococon.lt Ltd. Ecococon

Page 6: ECOcocon_A4_12-EN

angular and rectangular panel

1225

3000

Sta

ndar

d

400 - 1200 Option

300

- 300

0O

ptio

n

400

95 95210

4545 45

1200 Standard

45

45

300

- 300

0 O

ptio

n

400 - 1200 Option

45° - 90° Option

45

12

Fixed

[email protected] www.ecococon.lt Ltd. Ecococon

Page 7: ECOcocon_A4_12-EN

lintel and sill

400 - 3000 Option

300

- 300

0 O

ptio

n

45 95 95 12

9595

400 - 3000 Option

4512

12

9595

300

- 120

0 O

ptio

n

95

[email protected] www.ecococon.lt Ltd. Ecococon

Page 8: ECOcocon_A4_12-EN

installation

~ 47

3~

473

~ 468~ 468

45

9595

210

400

1000600600600

8x100 Screw

STEICO underfloor 5mm

Anchor to foundation