3
PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E INDOOR UNIT Wall mounted type Elegant Design and Compact Dimensions Ideal for Offices, Stores and Residential Uses. PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E PKFY-P VFM PKFY-P VGM PKFY-P VAM Front grille opens out P20 Capacity P25 P32 P40 P50 VAM VGM VFM P63 P100 Capacity range 3 1 2 Width reduced by 20% to a compact 990mm*. *: 39in. Extra compactness has been achieved thanks to a 20%(260mm(10- 1 /4in.)) reduction in which compared with previous models. Compact design with 990mm* width (PKFY-P VGM) The front power supply box allows electrical wiring work to be done after the indoor unit has been installed. For easier installation, all the screws required for securing the indoor unit to the wall are accessible from the front of the unit. Front power supply box for easier wiring even after installation All piping including drainage can be connected from the rear, right, base, and left of the unit, providing much greater flexibility out piping and selecting installation site. 5-way piping provides more flexibility in selecting installation sites Compact 295mm(11- 5 /8in.) high body fits snugly in even limited spaces (PKFY-P VAM) Lightweight 8.5kg(20lbs) unit easy to transport and install (PKFY-P VAM) Auto-flap shutter enhances good looks In room air conditioning style, the grille opens out allowing the filter to be removed. The filter and open grille can therefore be thoroughly and easily cleaned. Among the quietest in the industry Airflow passage configuration that assures quiet operations 1. The unit incorporates a randon pitch cycling fan. By changing fan intervals reduction in airflow. Optimal design of the airflow passage gives a shorted fan diameter and allows a highly compact installation. 2. Thanks to a highly practical casing configuration, airflow generated by the fan is distributed uniformly. 3. Due to careful positioning of the vertical vane axis, air is blown evenly from the fan. This prevents mixing with secondary air, and also suppresses condensation. Quiet operation (PKFY-P VGM) Front grille opens out - easy filter cleaning (PKFY-P VGM) 37

Elegant Design and Compact Dimensions Ideal for Offices ... · PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E INDOOR UNIT Wall mounted type Elegant Design and Compact Dimensions Ideal for

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Elegant Design and Compact Dimensions Ideal for Offices ... · PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E INDOOR UNIT Wall mounted type Elegant Design and Compact Dimensions Ideal for

PKFY-P VAM-EPKFY-P VGM-EPKFY-P VFM-E

INDOOR UNIT

Wall mountedtype

Elegant Design and Compact Dimensions Ideal for Offices,

Stores and Residential Uses.

PKFY-P VAM-EPKFY-P VGM-EPKFY-P VFM-E

PKFY-P VFM

PKFY-P VGMPKFY-P VAM

Front grille opens out

P20Capacity P25 P32 P40 P50

VAM

VGM

VFM

P63 P100

Capacity range

3

1

2

Width reduced by 20% to a compact

990mm*. *: 39in.

Extra compactness has been achieved thanks

to a 20%(260mm(10-1/4in.))

reduction in which compared with previous

models.

Compact design with 990mm* width

(PKFY-P VGM)

The front power supply box allows electrical

wiring work to be done after the indoor unit

has been installed. For easier installation, all

the screws required for securing the indoor

unit to the wall are accessible from the front

of the unit.

Front power supply box for easier wiring even after installation

All piping including drainage can be

connected from the rear, right, base, and left

of the unit, providing much greater flexibility

out piping and selecting installation site.

5-way piping provides more flexibility in selecting installation sites

Compact 295mm(11-5/8in.) high body fits snugly in even limited spaces (PKFY-P VAM)

Lightweight 8.5kg(20lbs) unit easy to transport and install (PKFY-P VAM)

Auto-flap shutter enhances good looks

In room air conditioning style, the grille

opens out allowing the filter to be removed.

The filter and open grille can therefore be

thoroughly and easily cleaned.

Among the quietest in the industryAirflow passage configuration that assures quiet operations

1. The unit incorporates a randon pitch cycling fan. By changing fan

intervals reduction in airflow. Optimal design of the airflow passage

gives a shorted fan diameter and allows a highly compact installation.

2. Thanks to a highly practical casing configuration, airflow

generated by the fan is distributed uniformly.

3. Due to careful positioning of the vertical vane axis, air is blown

evenly from the fan. This prevents mixing with secondary air,

and also suppresses condensation.

Quiet operation (PKFY-P VGM)

Front grille opens out - easy filter cleaning (PKFY-P VGM)

37

Page 2: Elegant Design and Compact Dimensions Ideal for Offices ... · PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E INDOOR UNIT Wall mounted type Elegant Design and Compact Dimensions Ideal for

External Dimensions

Specifications

INDOOR UNIT

Specifications & External Dimensions

Unit : mm

PKFY-P VAM-EPKFY-P VGM-E

PKFY-P20VAM-E~ 220-240V 50Hz ~ 220V 60Hz

PKFY-P25VAM-E PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E

2,000 2,500 5,000

2.2 2.8 5.6

2.5 3.2 6.3

0.040.040.200.20

Power source

Cooling capacity

kWCoolingHeatingCoolingHeating

kWA

A

kg(lbs.)

m 3/min

Pa

L/scfm

kW

mm(in.)

mm(in.)

dB(A)

Heating capacity

Powerconsumption

Current

External finish(Munsel No.)

Net weight Heat exchanger

Fan

Type

Airflow rate g 3

(Lo-Mid2-Mid1-Hi)

External static pressure

MotorOutput

Type

Air filter

Refrigerant pipe diameter

Gas(Flare)

Liquid(Flare)

Drain pipe diameterNoise level (Lo-Mid2-Mid1-Hi) g3 g4

Plastic 2.60Y 8.66/0.69

8.5(19)

Line flow fan 51

4.9-5.2-5.6-5.982-87-93-98

173-184-198-208133-158-175-192283-335-371-406

150-167-183-200318-353-388-424

0Single phase induction motor

PP Honeycomb (long life)

ø 12.7(1/2")

ø 6.35(1/4")

I.D. ø16 (VP-16) I.D. ø20 (VP-20)

32-33-35-36

0.017

Cross fin (Aluminum plate fin and copper tube)

3,150 4,000

3.6 4.5

4.0 5.0

0.070.070.320.32

Plastic <PS,ABS> white 0.70Y 8.59/0.97

16(36)

8-9.5-10.5-11.5

33-36-38-41

0.030

9-10-11-12

34-37-40-43

7,500 9,600 12,3002.3 2.9 3.7

15,400 19,1005.84.7

2,200 2,800 3,4008,500 10,900 13,600

4,300 5,40017,100 21,500

ø 12.7(1/2") / ø 15.88(5/8")(Compatible)

ø 6.35(1/4") / ø 9.52(3/8")(Compatible)

mm(in.)Dimension H x W x D 295 x 815 x 158 (11-5/8" x 32-1/8" x 6-1/4") 340 x 990 x 235 (13-7/16" x 39" x 6-5/16")

kcal/h

kWg 1

g 2

kcal/hkWg 1

g 1

BTU/hkW

g 1

g 2

BTU/hg 1

Note:

g 3 Airflow rate/noise level are in (low-middle2-middle1-high).g 4 It is measured in anechoic room.

g 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DBHeating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB

g 2 Cooling capacity indicates the maximum value at operation under the following condition.Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F))Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F))

2.5 60 150

520 Liquid pipe

450 Gas pipe

660 (Total length of drain piping 760) 110

116

5

60

146

37.4

70.3

630 Intake dimensions

13

13

25

.5

695 Outlet dimensions

29

5

21.5

815

783

158

PKFY-VAMMITSUBISHI

Adress board

Remote controlterminal plate

Power terminal plate

Inta

ke

dim

en

sio

ns

Dip switch (switches functions)

Rotary switch (own address)

Rotary switch (pair No.)

Address board

Installation board

Terminal plateOutletdimensionsOutlet

direction

Intakedirection

Outletangle

17˚

247.5 Intake dimensions

The address board is protected bya plastic cover.Remove the cover with a screwdriver(one screw) to set the board.

Liquid pipe ø6.35

Gas pipe ø12.7

PKFY-P20, 25VAM-E

Knock out hole for right piping Refrigerant pipe.Drain pipe.Wiring hole

Gas pipeLiquid pipe

Address board

Terminal block for power supply

Terminal block forremote control

Filter grip

2121

Knock out hole for under pipingRefrigerant piping.Drain pipe.Wiring hole

Service panel(Power supply access)

Gas pipe

ø12.7

Liquid pipe

ø6.35

50

32,40

Model

(Flexible hose total length 800)(Right side piping installation)

(Left side piping installation)

Drain pipe (O.D. ø20)

Front view(to open the grille)

12-Louvers (manual)

Air outletLower side

Auto vane

Left sideFront view

Air intake

Air intake

Air intake

Air

inta

ke

Knock out hole for left piping Refrigerant pipe.Drain pipe.Wiring hole.

Right side

35

700 153

549 86

481 54

3128

0

80

60

7024

5

50

395400

190

60

70 35

79

160 40

705 235

Less than 15

198

7024

5

60

235

53

340

715 225

340 80 280 233

990

MITSUBISHI ELECTRIC

ø 6.35(R410A) ø9.52(R407C,R22)

ø 12.7(R410A) ø15.88(R407C,R22)

PKFY-P32,40,50VGM-E

54

Page 3: Elegant Design and Compact Dimensions Ideal for Offices ... · PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E INDOOR UNIT Wall mounted type Elegant Design and Compact Dimensions Ideal for

External Dimensions

Specifications

INDOOR UNIT

Specifications & External Dimensions

PKFY-P63VFM-E PKFY-P100VFM-E Unit : mm

PKFY-P63VFM-E PKFY-P100VFM-EPower source

kcal/h

kW

BTU/hCooling capacity

g 1

g 2

g 1

g 1

g 1

kW

BTU/hkWCooling

Heating

Cooling

Heating

kW

A

A

mm(in.)

mm(in.)

mm(in.)

kg(lbs.)

m3/min

Pa

kW

mm(in.)

mm(in.)

dB(A)

Heating capacity

Powerconsumption

Current

External finish(Munsel No.)

Dimension

Height

Width

Depth

Net weight

Heat exchanger

Fan

Type

Airflow rate g 3(Lo-Hi)

External static pressure

MotorOutput

Type

Air filter

Refrigerant pipe diameter

Gas(Flare)

Liquid(Flare)

Drain pipe diameter

Noise level (Lo-Hi) g3 g4

220-230-240V 50Hz / 220V 60Hz

6,300

7.1

24,200

8.0

27,300

0.12

0.12

0.55

0.55

Plastic, white : <3.4Y7.7/0.8>

340(13-3/8)

1,400(55-1/8)

235(9-1/4)

340(13-3/8)

235(9-1/4)

24(53)

Line flow fan 5 2

15-20

0

Single phase induction motor

PP Honeycomb (antibacterial)

ø15.88(5/8)

I.D. ø20 (VP-20)39-45

0.040

Cross fin (Aluminum plate fin and copper tube)

10,000

11.2

38,200

12.5

42,700

0.14

0.14

0.64

0.64

28(62)

22-28

ø15.88(5/8) / ø19.05(3/4)

ø9.52(3/8)

41-46

0.070

1,680(66-1/8)

PKFY-P VFM-E

g1 Cooling Indoor: 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB, Outdoor: 35˚C(95˚F)DB

Heating Indoor: 20˚C(68˚F)DB, Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB

g2 Cooling Indoor: 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB, Outdoor: 35˚C(95˚F)DB

g3 Airflow rate/noise level are in (low-high).

g4 It is measured in anechoic room.

Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition.

91

225

184

30

240 180 280 314

18 18

10X91=(910) 285

30

30

19900

90610

280

60

245455

29

10

990

80

12-ø6 holefor tapping screw

32-ø12 hole

for bolt

Wall fixture

Rear piping hole

66-ø6 hole

for tapping

screw

Unit center

Bolt

Less than 15

Drain hose

111

Drain hose for

left-hand side piping

107

183

55(Gas pipe)

120(Liquid pipe)

42 58

Drain hose

45 45 45

Knock out hole for wiring

A B C3030

39

B

A

74

C

9837

7437

65

4

39

39

100

32

37

100

4

552 Air outlet

1120

340 197

13

62.5

235 235

1400

240

1090 Air intake

235

552 Air outlet

235

235

1

2

25

1110 (Drain hose)

Knock out hole

for left piping

Drainage range on left hand side

Knock out hole for under-piping

Refrigerant pipe .Drain pipe

Drainage range on right-hand side

Left side

Lower side louvers(manual)Auto vanes

Range for left rear piping hole

Under panel(Removable at

left-hand side piping)

Unit out line

Wall fixture

Rear piping hole

295 225

Range for left rear piping hole

30

184

240 180 280 314

1818

80

13X91=(1183)

91

1270

10

30

30

19900

595

750

60

245

285

90

29

280

84-ø6 hole

for tapping

screw

41-ø12 hole

for bolt

12-ø6 hole

for tapping screw

Unit center

Bolt

Range for left rear piping hole

Drainage range on left hand side

Drainage range on right-hand side

1

2

A

A CB

100

439

7437

65

37

393298

4

7437

39100

30 30

Drain hose for

left-hand side piping

42

58

694 Air outlet240

45

340

13

45

62.5

235 45235

1400

235

1370 (Air intake)

235

183

55 (Gas pipe)

Under panel(Removable at left-hand side piping)

120 (Liquid pipe)

694 Air outlet

235

C

Drain hose

1680

Less than 15

111

102

1110 (Drain hose)

25

197

235

Knock out hole

for left piping

Knock out hole for under-piping

Refrigerant pipe .Drain pipe

Right side

Left side

Top

45

Lower side

louvers(manual) B

Knock out hole for wiring

Auto vanes

Front Knock out hole

for right piping

55