Upload
nguyenthuy
View
215
Download
1
Embed Size (px)
Citation preview
Eloma Genius T6-11 Gas Full-Size Combination Oven Performance Test
Application of ASTM Standard
Test Method F 1639- 05 SCGAT060116A
Energy Resource Center Downey, CA
February 2007
Prepared by: The Gas Company
© 2009 Southern California Gas Company. All trademarks belong to their respective owners. All rights reserved.
Disclaimer "The information and analysis contained in this report is based on data collected at the Energy Resource Center. The Gas Company has made reasonable efforts to ensure that all information is correct; however, the Gas Company makes no representation or warranty, express or implied, as to the accuracy, correctness or usefulness of any data or information in this report. Nothing contained in this report is intended to constitute a recommendation, endorsement, approval or guaranty of any product or service. The Gas Company shall not be responsible for errors or omissions in this report or for claims or damages relating to the use of this report, even if it has been advised of the possibility of such damages. All trademarks, methods, processes or other intellectual property contained in or described in this report are the property of their respective owners and the Gas Company makes no representation or warranty that their use will not infringe privately owned rights." Legal Notice “This report was prepared as a result of work sponsored by the California Public Utilities Commission (Commission). It does not necessarily represent the views of the Commission, its employees, or the State of California. The Commission, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, or assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the Commission nor has the Commission passed upon the accuracy of the information in this report."
Executive Summary
The Eloma Genius T6-11 gas-fired combination oven (Fig.1) was tested
by the Gas Company for inclusion into its cooking energy efficiency
program. Gas Company engineers tested the gas combination oven
according to the specifications of the American Society for Testing and
Materials’ (ASTM) standard test method F 1639. To be considered
energy efficient, a convection oven must achieve at least 40% efficiency
for the heavy-load cooking-energy efficiency test. The Eloma Genius
T6-11 oven passed the standards as set forth. The test results for the
Eloma Genius T6-11 are as follows: Fig.1
Table ES-1. Summary of ASTM Convection Oven Performance Results
Rated Energy Input Rate (Btu/h) 40,100 Measured Energy Input Rate (Btu/h) 42,917 Preheat Time to 340°F (min) 13.6 Preheat Energy to 340°F (Btu) 9,956 Idle Energy Rate @ 350°F (Btu/h) N/A Pilot Energy Rate (Btu/h) N/A Heavy-load cooking-energy Efficiency (%) 58.4 Production Capacity (lb/h) 54.2
The heavy-load cooking-energy efficiency test consists of cooking whole
chickens on the maximum number of chicken racks allowable by the
manufacturer (in this case, 16). As specified by the ASTM test method,
cooking-energy efficiency is a measure of how much of the energy that
an appliance consumes is actually delivered to the food product during
the cooking process. Cooking-energy efficiency is therefore defined by
the following relationship:
Appliance Energy toFood Energy toEfficiencyEnergy Cooking =
Commercial Foodservice Equipment Testing Program
Recent advances in equipment design have produced commercial
foodservice equipment that operates more efficiently, quickly, safely and
conveniently. Energy efficient commercial equipment reduces energy
consumption primarily through advanced technology and design.
The purpose of the The Gas Company’s Energy Efficiency Commercial
Foodservice Equipment Testing Program is to provide energy efficiency
measurement data for cost effectiveness modeling in order to establish
energy efficiency standards and ratings for commercial food service
equipment. This measurement data is then utilized and integrated with
typical equipment usage profiles for California utility customer
participants for the Food Service Equipment Rebate program.
ERC FOODSERVICE TEST CENTER RESULTS REPORTING SHEET COMMERCIAL COOKING EQUIPMENT TESTING PERFORMANCE OF COMBINATION OVENS SCG PROJ. NO.: W0601 FEBRUARY 12, 2006 ASTM F 1639-05 – 1
Performance of Combination Ovens RESULTS REPORTING SHEET
ASTM F 1639-05
Manufacturer ELOMA
Model GENIUS T 6-11
Serial # 775908
Date 1/22/07 – 1/23/07
Test Reference Number (Optional)
Test Oven Description
Description of operational characteristics:
Physical Dimensions
Size of oven: 29.25 H x 36.5 W x 31.5 D in.
Number of racks: 6
Space between racks: 2.00 in.
Apparatus
√ Check if testing apparatus conformed to specifications in Section 5.
Deviations:
Thermostat Calibration
As-Received:
Oven temperature control setting (°F) 351
Oven cavity temperature (°F) 342.4
As-Adjusted:
Oven temperature control setting (°F) 361
Oven cavity temperature (°F) 354.6
RESULTS REPORTING SHEET ERC FOODSERVICE TEST CENTER PERFORMANCE OF COMBINATION OVENS COMMERCIAL COOKING EQUIPMENT TESTING FEBRUARY 12, 2006 SCG PROJ. NO.: W0601 ASTM F 1639-05 – 2
Energy Input Rate
Test Voltage (V) 117.5
Gas Heating Value (Btu/ft3) 1032
Rated (Btu/h) 40,100
Measured (Btu/h) 42,917
Percent Difference between Measured and Rated (%) 7.0
Fan/Control Energy Rate (kW) 0.1362
Preheat Energy and Time
Test Voltage (V) 118.4
Gas Heating Value (Btu/ft3) 1030
Energy Consumption (Btu) 9,956
Time from °F to 350°F (min) 13.6
Idle Energy Rate
Test Voltage (V)
Gas Heating Value (Btu/ft3)
Humidity Setting Maximum (100%)
Idle Energy Rate (Btu/h)
Water Consumption Rate (gal/h)
Pilot Energy Rate
Gas Heating Value (Btu/ft3) N/A
Pilot Energy Rate (Btu/h) N/A
Cooking Energy Efficiency and Cooking Energy Rate Check if oven was set at 350°F and full combination mode (maximum humidity) for the
duration of the tests.
Alternate Cooking Program:
Tests were performed using the factory installed program of “grilled chicken.”
ERC FOODSERVICE TEST CENTER RESULTS REPORTING SHEET COMMERCIAL COOKING EQUIPMENT TESTING PERFORMANCE OF COMBINATION OVENS SCG PROJ. NO.: W0601 FEBRUARY 12, 2006 ASTM F 1639-05 – 3
Light-Load:
Test Voltage (V)
Gas Heating Value (Btu/ft3)
Cooking Energy Efficiency (%)
Cooking Energy Rate (Btu/h)
Electric Energy Rate (kW)
Cooking Time (min)
Shrinkage (%)
Water Consumption (gal/h)
Condensate Temperature Max. (°F)
Condensate Temperature Average (°F)
Heavy-Load:
Test Voltage (V) 118.0
Gas Heating Value (Btu/ft3) 1031
Cooking Energy Efficiency (%) 58.4 ± 1.17
Production Capacity (lb/h) 54.2 ± 1.93
Cooking Energy Rate (Btu/h) 32,489
Electric Energy Rate (kW) 0.1368
Cooking Time (min) 39.9
Shrinkage (%) 17.2
Water Consumption (gal/h) 0.79
Condensate Temperature Max. (°F) 119.3
Condensate Temperature Average (°F 97.8
RESULTS REPORTING SHEET ERC FOODSERVICE TEST CENTER
Preheat Curve
50
75
100
125
150
175
200
225
250
275
300
325
350
375
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Time (min)
Tem
pera
ture
(°F)
Signatures: The undersigned have performed the above test and have verified that the results recorded were the actual results observed.
SCG’s Tester: 02/12/07 (signature) (date)
ANDRE SALDIVAR (print name)
PERFORMANCE OF COMBINATION OVENS COMMERCIAL COOKING EQUIPMENT TESTING FEBRUARY 12, 2006 SCG PROJ. NO.: W0601 ASTM F 1639-05 – 4
ERC FOODSERVICE TEST CENTER UNCERTAINTY CALCULATION PROCEDURE COMMERCIAL COOKING EQUIPMENT TESTING FOODSERVICE TESTING SCG PROJ. NO.: W0601 FEBRUARY 12, 2006 Annex – 1
Foodservice Testing UNCERTAINTY CALCULATION PROCEDURE
Annex
Make: ELOMA
Model: GENIUS T6-11
Equipment Type: Combination Oven
Test Results from Form: ASTM F 1639 – 05 (10.7)S
Results Evaluated: Cooking Energy Efficiency
A. Test results
1. Iteration 1 X1 = 58.8
2. Iteration 2 X2 = 57.1
3. Iteration 3 X3 = 59.3
4. Iteration 4 X4 =
5. Iteration 5 X5 =
6. Number of test results being evaluated: n = 3
B. Calculations
1. Xan = (1/n) * (X1 + X2 + … + Xn) Xan = 58.4
2. Sn = 2
nn BA − Sn = 0.01177
a. An = (X1)² + (X2)² + … + (Xn)² An = 1.0242
b. Bn = (1/n) * (X1 + X2 + … + Xn) ² Bn = 1.0239
3. Un= Cn * Sn Un = 0.02919
a. Cn is found in the following table: Cn = 2.48
Uncertainty Factors
Test Results, n Uncertainty Factors, Cn
3 2.48 4 1.59 5 1.24 6 1.05 7 0.92 8 0.84 9 0.77 10 0.72
UNCERTAINTY CALCULATION PROCEDURE ERC FOODSERVICE TEST CENTER
4. %Un = (Un / Xan) * 100% %Un = 5.0
C. Evaluation YES NO N/A
1. Is %Un ≤ ±10% [yes]
a. If %Un ≥ ±10% then repeat the test. Notes:
1. Expected results are shown between brackets. Comments:
Signatures: The undersigned have performed the above test and have verified that the results recorded were the actual results observed.
SCG’s Tester: 2/12/07 (signature) (date)
ANDRE SALDIVAR (print name)
FOODSERVICE TESTING COMMERCIAL COOKING EQUIPMENT TESTING FEBRUARY 12, 2006 SCG PROJ. NO.: W0601 ANNEX – 2
ERC FOODSERVICE TEST CENTER UNCERTAINTY CALCULATION PROCEDURE COMMERCIAL COOKING EQUIPMENT TESTING FOODSERVICE TESTING SCG PROJ. NO.: W0601 FEBRUARY 12, 2006 Annex – 1
Foodservice Testing UNCERTAINTY CALCULATION PROCEDURE
Annex
Make: ELOMA
Model: GENIUS T6-11
Equipment Type: Combination Oven
Test Results from Form: ASTM F 1639 – 05 (10.7)S
Results Evaluated: Production Capacity
A. Test results
1. Iteration 1 X1 = 52.1
2. Iteration 2 X2 = 54.6
3. Iteration 3 X3 = 55.9
4. Iteration 4 X4 =
5. Iteration 5 X5 =
6. Number of test results being evaluated: n = 3
B. Calculations
1. Xan = (1/n) * (X1 + X2 + … + Xn) Xan = 54.2
2. Sn = 2
nn BA − Sn = 1.932
a. An = (X1)² + (X2)² + … + (Xn)² An = 8816.3
b. Bn = (1/n) * (X1 + X2 + … + Xn) ² Bn = 8808.8
3. Un= Cn * Sn Un = 4.79
a. Cn is found in the following table: Cn = 2.48
Uncertainty Factors
Test Results, n Uncertainty Factors, Cn
3 2.48 4 1.59 5 1.24 6 1.05 7 0.92 8 0.84 9 0.77 10 0.72
UNCERTAINTY CALCULATION PROCEDURE ERC FOODSERVICE TEST CENTER
4. %Un = (Un / Xan) * 100% %Un = 8.8
C. Evaluation YES NO N/A
1. Is %Un ≤ ±10% [yes]
a. If %Un ≥ ±10% then repeat the test. Notes:
1. Expected results are shown between brackets. Comments:
Signatures: The undersigned have performed the above test and have verified that the results recorded were the actual results observed.
SCG’s Tester: 2/12/07 (signature) (date)
ANDRE SALDIVAR (print name)
FOODSERVICE TESTING COMMERCIAL COOKING EQUIPMENT TESTING FEBRUARY 12, 2006 SCG PROJ. NO.: W0601 ANNEX – 2