6
SUPERIOR STRENGTH * & PROFILE FOR UNCOMPROMISED PERFORMANCE ORTHOLOC 2 with Technology Ankle Fracture LP System 3Di

eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

SUPERIOR STRENGTH * & PROFILE FOR

UNCOMPROMISED PERFORMANCE

ORTHOLOC™ 2 with Technology

Ankle Fracture LP System

3Di

Page 2: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

15° 15°

Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary

plate hole design strikes a perfect balance for an unsurpassed locking mechanism

» Off axis locking up to 15°, in any direction, with the ability to relock screws up to 3 times

» Available in 2.7mm and 3.5mm diameters

Technology

* Data on file.**Based on publicly available product literature

SpeedImplants and Instruments Designed to Reduce Steps and Improve Efficiency

ASTM F138 ASTM F136 ASTM F136

Fati

gu

e St

ren

gth

at

10 M

illio

n C

ycle

s(%

) Material Fatigue Strength*

60%Stronger

33%Stronger

Type IIAnodized

ColorAnodized

StainlessSteel

100.00

80.00

60.00

40.00

20.00

0.00

Strength of Type II Anodized TitaniumProfile

Low-Profile Plates Designed to Reduce Soft Tissue Irritation

Strength*

Type II Ti Alloy Provides Increased Material Fatigue Strength Superior to Color Anodized Ti Alloy & Stainless Steel

Superior Strength* & Profile for Uncompromised Performance

1.3mm1.5mm

Lateral Fibula PlateLateral Fibula Plate

14% Decrease in Plate Thickness VS Arthrex Lateral Fibula Plate**

Page 3: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

Offset Lateral Fibula Plates » 1.5mm to 1.3mm proximal to distal plate

profile transition » Lengths range from 77mm to 125mm » Feature syndesmotic holes positioned

posterior, relative to the plate axis, allowing for syndesmotic fixation in the same plane as the syndesmosis

Straight Lateral Fibula Plates Feature a linear hole configuration with syndesmotic holes that allow for up to 30 degrees of anterior angulation

Straight Lateral Fibula Plate

Offset Lateral Fibula Plate

Page 4: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

GRAVITY™ SYNCHFIX™ Syndesmosis Fixation Device

System features low-profile non-locking , polyaxial, cortical, cancellous, and cannulated compression screws

System features bone clamps and other surgical instrumentation designed to facilitate treatment of numerous indications

2.7mm 3.5mm 4.0mm

Screws and corresponding instrumentation are color-coded, which streamlines use and reduces complexity

Technique Minimizes Soft-Tissue and Neurovascular Impingement

The GRAVITY™ SYNCHFIX™ technique facilitates open attachment of the medial button, allowing for placement on bone, below the periosteum and visualization of the saphenous vein and nerve.

Closed medial button placement has been shown to impinge the local neurovascular structures at a rate of 55%.1

Color-Coded9 Different Screw Options

Comprehensive Instrumentation

1 Assessment of Anatomic Risk During Syndesmotic Stabilization With the Suture Button Technique Pirozzi, Kelly M. et al. The Journal of Foot and Ankle Surgery , Volume 54 , Issue 5 , 917 – 919

Page 5: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

Hook Plate » 2 different hook offsets address medial and lateral anatomy

» Hook width accepts up to 4.0mm screw

» Proximal compression slot designed to maximize bony apposition

Medial Tibia Plate » Low-profile design minimizes the likelihood of

soft-tissue irritation

» Distal screw cluster provides multiplanar stability

» Beveled plate tip eases subcutaneous insertion

Posterior Tibia Plate » Multiplanar screw configuration provides

rotational stability

» Distal screw trajectories avoid intra-articular anatomy

» Beveled plate tip eases subcutaneous insertion

1/3 Tubular Plate » 1.3mm profile facilitates contouring and reduces

soft-tissue irritation

» Beveled plate tip eases subcutaneous insertion

» Comprehensive range of sizes address a wide range of fracture patterns

Syndesmosis Plate » Offset designed to ensure fixation in the centroidal axis

of the syndesmosis

» Syndesmotic slots allow up 30 degrees of anterior screw angulation

» Plates accept syndesmotic screws

Plate Options

Page 6: eMedia - ORTHOLOC 2...Ankle Fracture LP System 3Di 15 15 Unsurpassed Polyaxial Locking » Titanium Nitride coated heads coupled with proprietary plate hole design strikes a perfect

™ and ® denote Trademarks and Registered Trademarks of Wright Medical Group N.V. or its affiliates.©2018 Wright Medical Group N.V. or its affiliates. All Rights Reserved.

015571B_16-Jan-2018

1023 Cherry Road Memphis, TN 38117 800 238 7117 901 867 9971 www.wright.com

56 Kingston RoadStaines-upon-ThamesSurrey TW18 4NLUnited Kingdom+44 (0)845 833 4435

161 Rue Lavoisier38330 Montbonnot Saint MartinFrance+33 (0)4 76 61 35 00