Report No.: RE150707C22B Page No. 1 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
EN 300 440 RF Test Report
Report No.: RE150707C22B
Test Model: EYAGJN
Received Date: Jul. 07, 2015
Test Date: Jul. 14, 2015
Issued Date: Apr. 14, 2017
Applicant: TAIYO YUDEN CO., LTD.
Address: 8-1, Sakae-cho, Takasaki-shi, Gunma, 370-8522, Japan
Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C.
Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN (R.O.C.)
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: RE150707C22B Page No. 2 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Table of Contents Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ...................................................................................................................... 4
2 Summary of Test Results ..................................................................................................................... 5
2.1 Test Instruments .................................................................................................................................. 6 2.2 Measurement Uncertainty ................................................................................................................... 7 2.3 Maximum Measurement Uncertainty .................................................................................................. 7 2.4 Modification Record ............................................................................................................................ 7
3 General Information .............................................................................................................................. 8
3.1 General Description of EUT ................................................................................................................ 8 3.2 Description of Test Modes ................................................................................................................... 9 3.2.1 Test Mode Applicability and Tested Channel Detail ........................................................................... 10 3.3 Description of Support Units ............................................................................................................. 12 3.3.1 Configuration of System under Test .................................................................................................. 12 3.4 General Description of Applied Standards ........................................................................................ 12
4 Test Procedure and Results .............................................................................................................. 13
4.1 Equivalent Isotropic Radiated Power ................................................................................................ 13 4.1.1 Limits of Equivalent Isotropic Radiated Power .................................................................................. 13 4.1.2 Test Procedures ................................................................................................................................. 13 4.1.3 Deviation from Test Standard ............................................................................................................ 13 4.1.4 Test Setup .......................................................................................................................................... 13 4.1.5 Test Results ....................................................................................................................................... 13 4.2 Permitted Range of Operating Frequencies ..................................................................................... 14 4.2.1 Limits of Permitted Range of Operating Frequencies ....................................................................... 14 4.2.2 Test Procedures ................................................................................................................................. 14 4.2.3 Deviation of Test Standard ................................................................................................................ 14 4.2.4 Test Setup .......................................................................................................................................... 14 4.2.5 Test Results ....................................................................................................................................... 14 4.3 Unwanted Emissions in the Spurious Domain .................................................................................. 15 4.3.1 Limit of Unwanted Emissions in the Spurious Domain ...................................................................... 15 4.3.2 Test Procedure .................................................................................................................................. 15 4.3.3 Deviation from Test Standard ............................................................................................................ 15 4.3.4 Test Setup .......................................................................................................................................... 15 4.3.5 Test Results ....................................................................................................................................... 16 4.4 Duty Cycle ......................................................................................................................................... 18 4.4.1 Limit of Duty Cycle ............................................................................................................................. 18 4.4.2 Test Procedures ................................................................................................................................. 18 4.4.3 Test Setup .......................................................................................................................................... 18 4.4.4 Test Results ....................................................................................................................................... 18 4.5 Receiver Spurious Radiation ............................................................................................................. 19 4.5.1 Limit of Receiver Spurious Radiation ................................................................................................ 19 4.5.2 Test Procedure .................................................................................................................................. 19 4.5.3 Deviation from Test Standard ............................................................................................................ 19 4.5.4 Test Setup .......................................................................................................................................... 19 4.5.5 Test Results ....................................................................................................................................... 20
5 Photographs of the Test Configuration ............................................................................................ 21
Appendix – Information on the Testing Laboratories ................................................................................ 23
Report No.: RE150707C22B Page No. 3 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Release Control Record
Issue No. Description Date Issued
RE150707C22B Original release Apr. 14, 2017
Report No.: RE150707C22B Page No. 4 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
1 Certificate of Conformity
Product: Wireless Module
Brand: TAIYO YUDEN
Test Model: EYAGJN
Sample Status: Engineering sample
Applicant: TAIYO YUDEN CO., LTD.
Test Date: Jul. 14, 2015
Standards: EN 300 440 V2.1.1 (2017-03)
The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.
Prepared by :
, Date: Apr. 14, 2017
Celine Chou / Specialist
Approved by
:
, Date: Apr. 14, 2017
Ken Liu / Senior Manager
Report No.: RE150707C22B Page No. 5 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
2 Summary of Test Results
The EUT has been tested according to the following specifications:
EN 300 440
Clause Test Parameter Result
4.2.2 Equivalent Isotropic Radiated Power (e.i.r.p) Pass
4.2.3 Permitted Range of Operating Frequencies Pass
4.2.4 Unwanted Emission in the Spurious Domain Pass
4.2.5.4 Duty Cycle Pass
4.3.5 Receiver spurious radiation Pass
Report No.: RE150707C22B Page No. 6 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
2.1 Test Instruments
Description & Manufacturer Model No. Serial No. Calibrated Date Calibrated UntilSpectrum Analyzer Agilent
E4440A MY46185282 Mar. 09, 2015 Mar. 08, 2016
BILOG Antenna SCHWARZBECK
VULB 9168 9168-161 Feb. 04, 2015 Feb. 03, 2016
HORN Antenna ETS
3117 00034130 Feb. 10, 2015 Feb. 09, 2016
HORN Antenna SCHWARZBECK
BBHA 9170 BBHA9170243 Feb. 05, 2015 Feb. 04, 2016
Preamplifier Agilent
8449B 3008A01976 Aug. 22, 2014 Aug. 21, 2015
Preamplifier Agilent
8447D 2944A10634 Aug. 22, 2014 Aug. 21, 2015
RF signal cable HUBER+SUHNER
SUCOFLEX 104 246272/4 Aug. 22, 2014 Aug. 21, 2015
RF signal cable HUBER+SUHNER
SUCOFLEX 104 254644+251640 Aug. 22, 2014 Aug. 21, 2015
RF signal cable HUBER+SUHNER
CA3501-3501-G.90(3m) &
CA3501-3501-F.90 (2m)
NF090(3m)*2 & TCF427S(2m)*1
Apr. 07, 2015 Apr. 06, 2016
Software ADT.
ADT_Radiated_ V7.6.15.9.4
NA NA NA
Antenna Tower Max-Full MFA-440H 1308111 NA NA
10dB Attenuation JFW
50HF-010-SMA NA NA NA
Turn Table ADT
NA SN30303 NA NA
Controller Max-Full MF7802 MF780208363 NA NA
Temperature & Humidity chamber TERCHY
MHU-225AU 920842 Jun. 18, 2015 Jun. 17, 2016
Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
to NML/ROC and NIST/USA. 2. The test was performed in HwaYa RF Chamber 2. 3. The horn antenna and preamplifier (model: 8449B) are used only for the measurement of emission
frequency above 1GHz if tested.
Report No.: RE150707C22B Page No. 7 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
2.2 Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.
Parameter Uncertainty
Radio frequency ±1.06x10-8
Radiated emission of transmitter, valid up to 26.5GHz ±3.294dB
Radiated emission of receivers, valid up to 26.5GHz ±3.294dB
Temperature ±0.23 °C
Humidity ±0.3 %
Voltages(DC) ±0.1 %
Voltages(AC, <10kHz) ±0.22 %
2.3 Maximum Measurement Uncertainty
For the test methods, according to ETSI EN 300 440 standard, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 [7] and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian)).
Maximum measurement uncertainty Parameter Uncertainty
Radio frequency ±1x10-7
Radiated emission of transmitter, valid to 26.5GHz ±6.0 dB Radiated emission of receiver, valid 26.5GHz ±6.0 dB Temperature ±1°C Humidity ±5.0 % Voltages(DC) ±1.0 % Voltages(AC, <10kHz) ±2.0 %
2.4 Modification Record
There were no modifications required for compliance.
Report No.: RE150707C22B Page No. 8 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
3 General Information
3.1 General Description of EUT
Product Wireless Module
Brand TAIYO YUDEN
Test Model EYAGJN
Status of EUT Engineering sample
Nominal Voltage 3Vdc (Host equipment)
Voltage Operation Range Vnom= 3.0 Vmin= 1.8 Vmax= 3.6
Temperature Operating
Range -40~85℃
Modulation Type GFSK
Transfer Rate 1Mbps
Operating Frequency 2403 ~ 2480MHz
Number of Channel 78
EIRP Power
(Measured Max. Average)4.38dBm
Antenna Type PCB antenna with -1.5dBi gain
Accessory Device NA
Data Cable Supplied NA
Note: This report is issued as a duplicate report to the original BV ADT report no.: RE150707C22-1. The difference compared with original report is updating standard to the latest version. Due to no effect on any test item, we didn’t re-test.
Report No.: RE150707C22B Page No. 9 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
3.2 Description of Test Modes
78 channels are provided to this EUT:
Channel FREQ. (MHz)
Channel FREQ. (MHz)
Channel FREQ. (MHz)
Channel FREQ. (MHz)
1 2403 21 2423 41 2443 61 2463
2 2404 22 2424 42 2444 62 2464
3 2405 23 2425 43 2445 63 2465
4 2406 24 2426 44 2446 64 2466
5 2407 25 2427 45 2447 65 2467
6 2408 26 2428 46 2448 66 2468
7 2409 27 2429 47 2449 67 2469
8 2410 28 2430 48 2450 68 2470
9 2411 29 2431 49 2451 69 2471
10 2412 30 2432 50 2452 70 2472
11 2413 31 2433 51 2453 71 2473
12 2414 32 2434 52 2454 72 2474
13 2415 33 2435 53 2455 73 2475
14 2416 34 2436 54 2456 74 2476
15 2417 35 2437 55 2457 75 2477
16 2418 36 2438 56 2458 76 2478
17 2419 37 2439 57 2459 77 2479
18 2420 38 2440 58 2460 78 2480
19 2421 39 2441 59 2461
20 2422 40 2442 60 2462
Report No.: RE150707C22B Page No. 10 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
3.2.1 Test Mode Applicability and Tested Channel Detail
EUT Configure
Mode
Applicable to Description
EIRP PR SE<1G SE1G
- √ √ √ √ -
Where EIRP: Equivalent Isotropic Radiated Power PR: Permitted Range
SE<1G: Spurious Emissions below 1GHz SE1G: Spurious Emissions above 1GHz
Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane.
Equivalent Isotropic Radiated Power:
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below. EUT Configure Mode Available Channel Tested Channel Modulation Type
- 1 to 78 1, 39, 78 GFSK
Permitted Range Test:
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below. EUT Configure Mode Available Channel Tested Channel Modulation Type
- 1 to 78 1, 39, 78 GFSK
Spurious Emissions Test (Below 1 GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below. EUT Configure Mode Available Channel Tested Channel Modulation Type
- 1 to 78 1 GFSK
Spurious Emissions Test (Above 1 GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below. EUT Configure Mode Available Channel Tested Channel Modulation Type
- 1 to 78 1, 78 GFSK
Report No.: RE150707C22B Page No. 11 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Test Condition:
Applicable to Environmental Conditions Input Power Tested by
EIRP 25deg. C, 60%RH 3Vdc Leo Chan
PR 25deg. C, 60%RH 3Vdc Leo Chan
SE<1G 25deg. C, 65%RH 3Vdc Cedric Wu
SE1G 25deg. C, 65%RH 3Vdc Cedric Wu
Report No.: RE150707C22B Page No. 12 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
3.3 Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.
ID Product Brand Model No. Serial No. FCC ID Remarks
A. DC Power
Supply Topward 6603D NA NA -
B. Notebook DELL E5430 2RL3YW1 FCC Doc Approved -
Note:
1. All power cords of the above support units are non-shielded (1.8 m).
2. Item A and B were placed under the testing table.
ID Descriptions Qty. Length (m)Shielding
(Yes/No) Cores (Qty.) Remarks
1. Power cable 1 1.8 N 0 -
2. USB cable 1 1.8 Y 0 -
3.3.1 Configuration of System under Test
3.4 General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the requirements of the following standards:
EN 300 440 V2.1.1 (2017-03)
All test items have been performed and recorded as per the above standards.
EUT (Power from host equipment)
Test table
Notebook (B) Power Supply (A)
(1) (2)
Report No.: RE150707C22B Page No. 13 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4 Test Procedure and Results
4.1 Equivalent Isotropic Radiated Power
4.1.1 Limits of Equivalent Isotropic Radiated Power
Condition Limit (e.i.r.p)
Under all test conditions AV:10dBm
4.1.2 Test Procedures
Refer to EN 300 440 V2.1.1 clause 4.2.2.3
4.1.3 Deviation from Test Standard
No deviation.
4.1.4 Test Setup
The test setup has been constructed as the normal use condition. Controlling software (provided by manufacturer) has been activated to set the EUT on specific status.
4.1.5 Test Results
Test Condition EIRP Power (dBm)
(CH1) 2403 MHz
(CH39) 2441 MHz
(CH78) 2480 MHz
Tnom(℃) +25 Vnom(v) 4.03 3.89 3.47
Tmin(℃) -40 Vmin(v) 4.37 4.31 3.90
Vmax(v) 4.38 4.30 3.91
Tmax(℃) +85 Vmin(v) 3.10 2.90 2.44
Vmax(v) 3.11 2.86 2.46
Report No.: RE150707C22B Page No. 14 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.2 Permitted Range of Operating Frequencies
4.2.1 Limits of Permitted Range of Operating Frequencies
The width of the power envelope is fH –fL for a give operating frequency. In equipment that allows adjustment or selection of different frequencies, the power envelope take up different positions in the allowed band. The frequency range is determined by the lowest value of fL and the highest value of fH resulting from the adjustment of the equipment to the lowest and highest operating frequency.
4.2.2 Test Procedures
Refer to EN 300 440 V2.1.1 clause 4.2.3.3.
4.2.3 Deviation of Test Standard
No deviation.
4.2.4 Test Setup
The EUT has been placed in an environment where the temperature can be controlled. The power source should be replaced by a power supply for voltage change. Before testing, the transmitter has to be able to send signal to receiver.
4.2.5 Test Results
Test Condition Frequency (MHz)
Lowest Highest
Tnom(℃) +25 Vnom(v) 2402.09 2480.87
Tmin(℃) -40 Vmin(v) 2402.09 2480.87
Vmax(v) 2402.04 2480.87
Tmax(℃) +85 Vmin(v) 2402.09 2480.87
Vmax(v) 2402.13 2480.86
Measured frequency (lowest and highest) FL= 2402.04 FH= 2480.87
Report No.: RE150707C22B Page No. 15 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.3 Unwanted Emissions in the Spurious Domain
4.3.1 Limit of Unwanted Emissions in the Spurious Domain
Frequency Range
47MHz to 74MHz 87.5MHz to 108MHz 174MHz to 230MHz 470MHz to 862MHz
Other Frequencies Below 1GHz
>1GHz
Limit (Operating) 4nW (–54dBm) 250nW (–36dBm) 1μW (–30dBm)
Limit (Standby) 2nW (–57dBm) 2nW (–57dBm) 2nW (–47dBm)
4.3.2 Test Procedure
Refer to EN 300 440 V2.1.1 clause 4.2.4.3.
4.3.3 Deviation from Test Standard
No deviation.
4.3.4 Test Setup
1. For the actual test configuration, please refer to the related Item in this test report (Photographs of the Test
Configuration).
2. The test setup has been constructed as the normal use condition. Controlling software (provided by
manufacturer) has been activated to set the EUT on specific status.
Report No.: RE150707C22B Page No. 16 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.3.5 Test Results
Worst-case Data:
Frequency Range 25MHz ~ 1GHz Operating Channel 1
Operating State Operating
Spurious Emission Level
Frequency (MHz)
Antenna Polarization
Level (dBm)
Limit (dBm)
Margin (dB)
64.95 H -72.45 -54.00 -18.45
87.47 V -63.86 -36.00 -27.86
97.57 H -72.63 -54.00 -18.63
195.81 V -76.92 -54.00 -22.92
199.30 H -73.19 -54.00 -19.19
480.05 H -73.83 -54.00 -19.83
480.83 V -69.70 -54.00 -15.70
624.50 H -69.13 -54.00 -15.13
647.80 H -70.60 -54.00 -16.60
699.45 V -67.15 -54.00 -13.15
817.49 V -67.37 -54.00 -13.37
839.24 V -66.69 -54.00 -12.69
Frequency Range 1GHz ~ 25GHz Operating Channel 1, 78
Operating State Operating
Spurious Emission Level
Channel Frequency
(MHz) Antenna
Polarization Level (dBm)
Limit (dBm)
Margin (dB)
1 4806.10 H -62.23 -30.00 -32.23
4806.18 V -61.88 -30.00 -31.88
78 4960.02 H -60.77 -30.00 -30.77
4960.08 V -61.08 -30.00 -31.08
Report No.: RE150707C22B Page No. 17 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Frequency Range 25MHz ~ 1GHz Operating Channel 1
Operating State Standby
Spurious Emission Level
Frequency (MHz)
Antenna Polarization
Level (dBm)
Limit (dBm)
Margin (dB)
338.62 H -64.33 -57.00 -7.33
484.87 V -63.31 -57.00 -6.31
497.87 H -62.91 -57.00 -5.91
507.62 V -64.00 -57.00 -7.00
530.37 V -63.81 -57.00 -6.81
564.50 H -61.59 -57.00 -4.59
574.25 V -62.77 -57.00 -5.77
611.62 H -61.22 -57.00 -4.22
623.00 V -62.92 -57.00 -5.92
634.37 H -62.06 -57.00 -5.06
761.12 V -61.92 -57.00 -4.92
793.62 H -63.58 -57.00 -6.58
Frequency Range 1GHz ~ 25GHz Operating Channel 1, 78
Operating State Standby
Spurious Emission Level
Channel Frequency
(MHz) Antenna
Polarization Level (dBm)
Limit (dBm)
Margin (dB)
1 2250.07 H -56.55 -47.00 -9.55
2251.18 V -54.54 -47.00 -7.54
78 2250.72 V -54.15 -47.00 -7.15
2251.22 H -56.03 -47.00 -9.03
Report No.: RE150707C22B Page No. 18 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.4 Duty Cycle
4.4.1 Limit of Duty Cycle
Frequency Band Duty Cycle Application
2400 MHz to 2483.5 MHz No Restriction Generic use
2400 MHz to 2483.5 MHz No Restriction Detection, movement and alert applications
(a) 2446 MHz to 2454 MHz No Restriction RFID
(b) 2446 MHz to 2454 MHz 15% RFID
5725 MHz to 5875 MHz No Restriction Generic use
9200 MHz to 9500 MHz No Restriction Radiodetermination: radar, detection, movement and alert applications
9500 MHz to 9975 MHz No Restriction Radiodetermination: radar, detection, movement and alert applications
10.5 GHz to 10.6 GHz No Restriction Radiodetermination: radar, detection, movement and alert applications
13.4 GHz to 14.0 GHz No Restriction Radiodetermination: radar, detection, movement and alert applications
17.1 GHz to 17.3 GHz DDA or equivalent
techniques
Radiodetermination: GBSAR detecting and movement and alert applications
24.00 GHz to 24.25 GHz No Restriction Generic use and for Radiodetermination: radar, detection, movement and alert applications
4.4.2 Test Procedures
Refer to EN 300 440 V2.1.1 clause 4.2.5.3.
4.4.3 Test Setup
The EUT was operated in normal operation condition.
4.4.4 Test Results
The duty cycle of this device declared by client is 100%.
Report No.: RE150707C22B Page No. 19 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.5 Receiver Spurious Radiation
4.5.1 Limit of Receiver Spurious Radiation
Frequency Range Frequencies below 1GHz Frequencies above 1GHz
Limit 2nW (–57dBm) 20nW (–47dBm)
4.5.2 Test Procedure
Refer to EN 300 440 V2.1.1 clause 4.3.5.3.
4.5.3 Deviation from Test Standard
No deviation.
4.5.4 Test Setup
1. For the actual test configuration, please refer to the related Item in this test report (Photographs of the
Test Configuration).
2. The test setup has been constructed as the normal use condition. Controlling software (provided by
manufacturer) has been activated to set the EUT on specific status.
Report No.: RE150707C22B Page No. 20 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
4.5.5 Test Results
Worst-case Data:
Frequency Range 25MHz ~ 1GHz Operating Channel 1
Spurious Emission Level
Frequency (MHz)
Antenna Polarization
Level (dBm)
Limit (dBm)
Margin (dB)
51.75 H -73.17 -57.00 -16.17
96.40 H -71.97 -57.00 -14.97
120.09 V -71.32 -57.00 -14.32
186.10 H -72.90 -57.00 -15.90
186.10 V -71.90 -57.00 -14.90
199.69 V -73.42 -57.00 -16.42
299.10 V -69.83 -57.00 -12.83
304.54 H -65.81 -57.00 -8.81
551.11 H -68.17 -57.00 -11.17
620.62 V -68.53 -57.00 -11.53
637.71 V -66.60 -57.00 -9.60
712.65 V -64.53 -57.00 -7.53
824.87 H -64.67 -57.00 -7.67
Frequency Range 1GHz ~ 25GHz Operating Channel 1, 78
Spurious Emission Level
Channel Frequency
(MHz) Antenna
Polarization Level (dBm)
Limit (dBm)
Margin (dB)
1 2250.27 V -54.52 -47.00 -7.52
2250.37 H -56.44 -47.00 -9.44
78 2249.93 H -56.63 -47.00 -9.63
2250.40 V -54.70 -47.00 -7.70
Report No.: RE150707C22B Page No. 21 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
5 Photographs of the Test Configuration
TX / RX Spurious Emission Test
Report No.: RE150707C22B Page No. 22 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Report No.: RE150707C22B Page No. 23 / 23 Report Format Version: 6.1.2Reference No.: 150707C22, 170412C40
Appendix – Information on the Testing Laboratories We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and approved according to ISO/IEC 17025. If you have any comments, please feel free to contact us at the following:
Linko EMC/RF Lab
Tel: 886-2-26052180
Fax: 886-2-26051924
Hsin Chu EMC/RF/Telecom Lab
Tel: 886-3-6668565
Fax: 886-3-6668323
Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892
Email: [email protected]
Web Site: www.bureauveritas-adt.com
The address and road map of all our labs can be found in our web site also. --- END ---