Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500
UV Electrical Cabinet (Machines 16 and above)
Confidential 2
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500General
Confidential 3
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500General (Cont.)
Confidential 4
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500General (Cont.)
The power cabinet is responsible for the following functions:
Supplying voltages & controlling the UV lamp system
Supplying voltages & controlling the cooler unit
Supplying voltages & controlling the extraction unit
Confidential 5
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500General (Cont.)
Wiring Notes:
Blue wire: 24VDC
Red wire: 110VAC
Black wire 400VAC
Confidential 6
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Units Description
Earth Leakage Relay
Electro Magnetic Compatibility
Filter A1.1
Q1.1 -Mains circuit breaker
Q2 -Transformer breaker
K2-UV Main Contactor
Confidential 7
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Units Description (cont.)
Safety Switch Relay K9:
Verify that the UV lamphead cover is closed and enables the UV main contactor K2.
Confidential 8
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Fuses
F1: 110 V out from the transformer, 2 Amps fuse
F2: 24VDC power supply output protection, 2 Amps fuse
F3: Shutter open signal to the shutter valve, 1.6 Amps fuse
Fuses
Confidential 9
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Safety Relays
Shutter Open
Shutter Close 1
Shutter Close 2
Over Tem’ (Lamp)
Lamp pressure
E.M Contact 1&2
Fusses
Confidential 10
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Units Description (cont.)
UV lamp High Voltage contactors:
Enable the high voltage to the lamp by levels (30%-100%).
K3 K4 K5.1 K5.2
Confidential 11
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Units Description (cont.)
Overload Relays:
• Q6.11 - Cooler Pump
• Q6.12 - Cooler Fan1
• Q6.22 - Cooler Fan2
• Q7 - Extract Fan Frequency Inverter A7
Contactors:
• K6.11-Cooler Pump Contactor
• K6.12-Cooler Fan1 Contactor
• K6.22-Cooler Fan2 Contactor
Confidential 12
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500
Extraction Fan Frequency Extraction Fan Frequency Inverter A7Inverter A7
Units Description (cont.)
Extraction fan frequency inverter A7:
Controls the air extraction flow rate, depending on the UV lamp power.
Confidential 13
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Units Description (cont.)
PLC Panel
Confidential 14
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel
Inputs:
R1: Shutter ON, from the machine
R3, R4 and R5: UV power bits, from the machine
R6: Extraction fan operation indication, from A7 (Inverter)
Confidential 15
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel (Cont.)
Inputs:
R7: Cooler pump or cooler fans trip indication
R8: Lamp head pressure switch, from the UV lamp head
R9: Lamp head cover status (closed/opened) indication
R10: Transformer Contactor Operation K2
R12: Alarm reset button
V2: 24VDC
0VD: 0VDC
Confidential 16
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel (Cont.)
Inputs and outputs:
I1: Transformer breaker
I2: Shutter opened indication, from the UV lamphead
I3: Shutter closed indication, from the UV lamphead
I4: Lamp head over temperature indication
Confidential 17
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel (Cont.)
Inputs and outputs (cont.):
I5: Emergency switch from the machine
I6: Cooler over temperature indication, from the thermal switch in the Cooler
I7: UV lamp power indication
I9: Cooler low level indication
I10: UV ON signal from the machine
0VD: 0VDC
QA1: Output signal to the extraction fan frequency inverter A7
Confidential 18
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel (Cont.)
Outputs:
Q1: Extraction fan frequency inverter A7
Q2: Operating power to the UV main contactor K2
Q3, Q4 and Q5: Output power for enabling the high voltage contactors
Q6: Enabling cooler pump and fans
Confidential 19
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500PLC Panel (Cont.)
Outputs Signals:
S1: UV ready signal to the machine
S2: Shutter open signal to the shutter valve
S3, S4 and S5: UV fault signal to the machine
Confidential 20
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Transformer
Receives an input of 380-480VAC.
Converts the voltage to 110VAC.
Confidential 21
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ850024VDC Power Supply
Receives an input voltage of 110VAC.
Converts the voltage to 24VDC for the PLC.
Confidential 22
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500High Voltage Transformer
Receives an input voltage of 230VAC.
Converts the voltage to 2000VAC for the UV lamp.
Confidential 23
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Capacitors
Supply the high voltage to the UV lamp
Confidential 24
Engineer Training
UV Electrical Cabinet (16 and above)
TJ8300 / TJ8500Electrical Connections
XPC1: Connected to the cooler.
XPC2: Connected to the cooler.
XPPT: Connected to the UV lamp head.
XPF7: Connected to the extraction fan.