    Contents

    Overview of parameter changes

    Changes of northbound interface parameters are listed as follows:

    1. Added parameters

    2. Optimized parameter value ranges

    Modified sequence of enumeration values

    Expanded parameter value ranges

    Narrowed parameter value ranges

    3. Modified parameter units

    4. Modified parameter default values

    Modified parameter default values because of optimized

    algorithms

    5. Optimized parameter IDs and names

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    3/14

    Overview of Parameter Changes

    Number of added parameters: 48

    Number of deleted parameters: 6

    Number of modified parameters: 22

    Number of parameters with modified IDs and names: 95

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    4/14

    Page 4

    Change Reason:

    The RscGroupand NODETORSCGRPMOs are associated by key parameters. In

    this version, three key parameters are added to the RscGroupMO. Accordingly,

    three parameters are also added to the NODETORSCGRPMO to ensure the

    accurate association between the two MOs. Note that the three added parameters

    in the NODETORSCGRPMO are not key ones. PTand SBTare mandatory

    parameters.

    Change Description (Three Examples):

    Added Parameters

    MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    Value Range Default Value

    NODETORSCGRP Added PN Added0~15 0

    NODETORSCGRP AddedPT

    Added PPP~6, MPGRP~8, ETH~9,

    ETHTRK~10N/A

    NODETORSCGRP Added SBT AddedBASE_BOARD~0,

    E1_COVERBOARD~3N/A

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    5/14

    Change Reason:

    According to the protocol, the sequence of enumeration values 480msand 512ms

    for the TimeToTriggerparameter in the CellDLIcicMcParaMO must be modified.

    After the modification, 480msis placed ahead of 512ms. In this version, the

    sequence of enumeration values for altogether five parameters are modified.

    Change Description (Two Examples):MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    Actual Value Range (New) Actual Value Range (Old)

    CellDLIcicMcPara Modified

    TimeToTrigger

    Modified0ms, 40ms, 64ms, 80ms, 100ms,

    128ms, 160ms, 256ms, 320ms,

    480ms, 512ms, 640ms, 1024ms,

    1280ms, 2560ms, 5120ms

    0ms, 40ms, 64ms, 80ms, 100ms,

    128ms, 160ms, 256ms, 320ms,

    512ms, 480ms, 640ms, 1024ms,

    1280ms, 2560ms, 5120ms

    CellULIcicMcPara Modified

    TimeToTrigger

    Modified 0ms, 40ms, 64ms, 80ms, 100ms,

    128ms, 160ms, 256ms, 320ms,

    480ms, 512ms, 640ms, 1024ms,

    1280ms, 2560ms, 5120ms

    0ms, 40ms, 64ms, 80ms, 100ms,

    128ms, 160ms, 256ms, 320ms,

    512ms, 480ms,640ms, 1024ms,

    1280ms, 2560ms, 5120ms

    Modified Sequence of Enumeration Values

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    6/14

    Page 6

    Change Reason:

    In the earlier versions, the UL and DL data rates at the logical port are set to 300 Mbit/s and

    450 Mbit/s respectively. Due to the addition of transmission overhead, the UL or DL data rate at

    the MAC layer over the air interface is lower than that at the logical port. The LTE, however,

    requires the UL and DL data rates at the MAC layer to reach 300 Mbit/s and 450 Mbit/s

    respectively. Therefore, the rate at the logical port must be higher than that at the MAC layer.

    Consider the peak rate case: The average packet size is 500 bytes and the UL and DL data

    rates at the MAC layer are 300 Mbit/s and 450 Mbit/s respectively. In this case, if the

    transmission overhead is 20%, the UL and DL data rates at the logical port must be 360 Mbit/s

    and 540 Mbit/s respectively.

    Change Description (Four Examples):

    Expanded Parameter Value Ranges

    MOC Parameter ID Parameter Name Value TypeGUI Value Range

    (New)

    GUI Value Range

    (Old)

    Actual Value Range

    (New)

    Actual Value Range

    (Old)

    RscGroup RXBW Rx Bandwidth Interval values 32~540000 32~450000 32~540000 32~450000

    RscGroup RXCIRRX Commited

    Information RateInterval values 64~540000 64~450000 64~540000 64~450000

    RscGroup RXPIRRX Peak Information

    RateInterval values 64~540000 64~450000 64~540000 64~450000

    RscGroup TXBW Tx Bandwidth Interval values 32~360000 32~300000 32~360000 32~300000

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    7/14

    Page 7

    MOCParameter

    IDParameter Name Value Type GUI Value Range (New) GUI Value Range (Old)

    Actual Value

    Range (New)

    Actual Value

    Range (Old)

    OMCh RT Route Type Enumeration values NEXTHOP(Next Hop)NEXTHOP(Next Hop),

    IF(Exit Interface)NEXTHOP NEXTHOP, IF

    OMCh SBT Subboard Type Enumeration values BASE_BOARD(Base Board)

    BASE_BOARD(Base Board),

    E1_COVERBOARD(E1 Cover

    Board)

    BASE_BOARD

    BASE_BOARD

    ,

    E1_COVERBO

    ARD

    Change Reason:

    For one parameter, its enumeration values in the associated MO are different from

    those in the associated MML commands. Therefore, the GUI value range of the

    parameter is modified by deleting unnecessary enumeration values to ensure the

    consistency.

    Change Description (Two Examples):

    Narrowed Parameter Value Ranges

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    8/14

    Change Reason:

    The unit of the PreAllocationWeight parameter in the ExtendedQci MO is

    incorrectly written as none in the earlier versions. In this version, the unit is

    modified to 0.1. The unit of only one parameter is modified in this version. The

    modification has no impact on the interconnection at the northbound interface.

    Change Description:

    Modified Parameter Units

    MOC MOC Change Type Parameter ID Parameter Change Type Unit (New) Unit (Old)

    ExtendedQci Modified PreAllocationWei

    ght

    Modified 0.1 none

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    9/14

    Change Reason:

    The GbrRbUsedHighThdand GbrRbUsedLowThdparameters in the

    CellRacThdMO are used to limit resources used by GBR services. In the earlier

    versions, the two parameters are set to relatively large values to prevent the

    eNodeB from limiting the resources used by GBR services. In this version, a

    dedicated switch is added to disable this limitation. Therefore, the default values ofthe parameters are optimized, which meet the requirements of various scenarios.

    The modifications have no impact on the interconnection at the northbound

    interface.

    Change Description

    Modified Parameter Default Values Because of

    Optimized Algorithms

    MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    Default Value

    (New)

    Default Value

    (Old)

    CellRacThd Modified GbrRbUsedHighThd Modified 95 100

    CellRacThd Modified GbrRbUsedLowThd Modified 90 99

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    10/14

    Change Reason:

    Names of some parameters are too brief and difficult for users to understand.

    Therefore, the names of altogether 95 parameters are modified. The modifications

    have no impact on the interconnection at the northbound interface.

    Change Description (Two Examples):

    Optimized Parameter Names

    MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    Parameter Name

    (New)

    Parameter Name

    (Old)

    ServiceIrHoCfgGro

    up

    Modified InterRatHoState Modified Inter-RAT handover

    state

    InterRatHoState

    RatFreqPriorityGro

    up

    Modified RatFreqPriorityGro

    upId

    Modified RAT frequency

    priority group ID

    RatFreqPriorityGro

    upId

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    11/14

    Change Reason:

    The Access attribute of these parameters is Read Only. If user want to modify

    these parameters, it need to be deleted first and then added. These parameters

    are not included in the last parameter list document, and Huawei provide these

    parameters in this version in order to provide the enhancement operation via

    northbound interface.

    Change Description (Two Examples):

    Added Parameters

    MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    Value Range Default Value

    RscGroup Modified OID Added 0~3 0

    IPPath Modified CN Added 0~7 0

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    12/14

    Change Reason:

    The current version supports the function that is used to automatically establish an

    IPSec tunnel between the eNodeB and the Mobility Management Entity (MME).

    However, the actual application scenario only require the system to establish

    IPSec tunnel between the eNodeB and the Security Gateway (Se-GW). Therefore

    the parameters related to MME are deleted.

    Change Description (Two Examples):

    Deleted Parameters

    MOC MOC Change

    Type

    Parameter ID Parameter

    Change Type

    MME Modified FirstIKEPeerName Deleted

    MME Modified FirstIPSecFlag Deleted

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)

    13/14

    Change Reason:

    To simplify creating an eNodeB or a cell via the northbound interface, eNodeB and

    cell templates are introduced in the northbound interface.

    Change Description (Two Examples):

    Added Parameters

    NBI MOC MOC Change

    Type

    NBI Parameter ID Parameter

    Change Type

    Value Range

    CELL Modified TEMPLATENAME Added 1~255

    ENODEB Modified TEMPLATENAME Added 1~255

  • 8/11/2019 ENodeB Material for Parameter Changes (V100R003C00 vs V100R003C00T)