PERFORMANCE Republic offers a complete line of regenerative blowers for high vacuum or compressed air applications in both horizontal and vertical mounted positions. TEFC motors are rated for 50/60 Hz operation and are cUL, UL, and CE certified. The impeller is directly connected to the motor shaft, providing powerful air force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. Constructed in robust die- cast aluminum, this low-maintenance, oil-free design provides continuous, dependable service to our customers. REGENERATIVE BLOWERS HRC 1102/1202 R MANUFACTURING EPUBLIC The performance curves are based on air at a temperature of 59 o F and an atmospheric pressure of 29.91 inch Hg with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 o F. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/-5% tolerance. The frequency tolerance is +/-2% maximum. Vacuum Pressure ©Republic Manufacturing 0 -160 100 200 300 400 Pressure -80 in. H2O m /hr 3 Vacuum mbar cfm 200 400 0 -300 0 100 300 0 500 400 200 50 100 150 -100 -200 -400 300 100 800 Suction Capacity Total Pressure Difference -40 -120 200 250 600 700 600 50 Hz 60 Hz 300 50 Hz 60 Hz -200 -500 700 1102 1202 1102 1202 1102 1202 1102 1202 Model Phase Frequency (Hz) Air flow (CFM/m 3/ hr) Rated Vacuum (in. H 2 O/mbar) Rated Pressure (in. H 2 O/mbar) Motor (HP/kW) Voltage (V) Current (A) Sound Level (dB) Weight (lb/kg) HRC 1102 3 50 306/520 173/430 265/660 14.8/11.0 200-240 r/345-415 Y 48.5 r/28.0 Y 74 230/104 60 364/620 185/460 241/600 16.9/12.6 220-275 r/380-480 Y 50.1 r/29.0 Y 78 HRC 1202 3 50 306/520 185/460 269/670 20.1/15.0 200-240 r/345-415 Y 56.3 r/32.5 Y 74 265/120 60 364/620 197/490 301/750 23.2/17.3 220-275 r/380-480 Y 60.0 r/34.5 Y 78

EPUBLIC HRC 1102/1202 MANUFACTURING REGENERATIVE … · MANUFACTURING HRC 1102/1202 The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EPUBLIC HRC 1102/1202 MANUFACTURING REGENERATIVE … · MANUFACTURING HRC 1102/1202 The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of

PERFORMANCE

Republic offers a complete line of regenerative blowers for high vacuum or compressed air applications in both horizontal and vertical mounted positions. TEFC motors are rated for 50/60 Hz operation and are cUL, UL, and CE certified. The impeller is directly connected to the motor shaft, providing powerful air force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. Constructed in robust die-cast aluminum, this low-maintenance, oil-free design provides continuous, dependable service to our customers.

REGENERATIVE BLOWERSHRC 1102/1202RMANUFACTURING

EPUBLIC

The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of 29.91 inch Hg with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 oF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/-5% tolerance. The frequency tolerance is +/-2% maximum.

Vacuum Pressure

©Republic Manufacturing

0-160

100

200

300

400

Pressure

-80 in. H2Om /hr3

Vacuum

mbar

cfm

200 4000-300

0

100

300

0

500

400

200

50 100 150

-100-200-400 300100 800

Suct

ion

Capa

city

Total Pressure Di�erence

-40-120 200 250

600

700

60050 Hz60 Hz

300

50 Hz60 Hz

-200

-500 700

11021202

11021202

11021202

11021202

Model PhaseFrequency

(Hz)Air flow

(CFM/m3/hr)Rated Vacuum (in. H2O/mbar)

Rated Pressure (in. H2O/mbar)

Motor(HP/kW)

Voltage(V)

Current(A)

Sound Level (dB)

Weight (lb/kg)

HRC 1102 350 306/520 173/430 265/660 14.8/11.0 200-240 r/345-415 Y 48.5 r/28.0 Y 74

230/10460 364/620 185/460 241/600 16.9/12.6 220-275 r/380-480 Y 50.1 r/29.0 Y 78

HRC 1202 350 306/520 185/460 269/670 20.1/15.0 200-240 r/345-415 Y 56.3 r/32.5 Y 74

265/12060 364/620 197/490 301/750 23.2/17.3 220-275 r/380-480 Y 60.0 r/34.5 Y 78

Page 2: EPUBLIC HRC 1102/1202 MANUFACTURING REGENERATIVE … · MANUFACTURING HRC 1102/1202 The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of

©Republic Manufacturing • Revised 20181218

APPROXIMATE DIMENSIONS

All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD’s, PLC’s, or starter panels.

Available Options

VACUUM KIT PRESSURE KIT

RMANUFACTURINGEPUBLIC 5131 Cash Road, Dallas, TX 75247, USA

800.847.0380 • [email protected] • republic-mfg.com

Model Unit A B D E F G J K M N O P

HRC1102

in 19.57 19.80M12

27.36 10.31 11.46 7.76 9.412.50

3.70 0.24 4.06

mm 497 503 695 262 291 197 239 94 6 103

HRC1202

in 19.57 19.80M12

27.36 10.31 11.46 7.76 9.412.50

3.70 0.24 4.06

mm 497 503 695 262 291 197 239 94 6 103

Model Unit Q R S T U V W X Y Z Z1

HRC1102

in 31.46 19.80 6.61 8.90 15.51 14.02 9.29 6.69 28.27 8.54 0.59

mm 799 202 168 226 394 356 236 170 718 217 15

HRC1202

in 31.46 19.80 6.61 8.90 15.51 14.02 9.29 6.69 28.26 8.54 0.59

mm 799 202 168 226 394 356 236 170 718 216 15