Extension Manual 2011

Embed Size (px)

Citation preview

  • 7/28/2019 Extension Manual 2011

    1/67

    STRAKONpremiumSTRAKONstandardSTRAKONlight

    Extension Manual

    Version 2011

  • 7/28/2019 Extension Manual 2011

    2/67

    This manual is protected by copyright law.

    2011 DICAD Systeme GmbH. All rights reserved.

    No part of this manual may be duplicated, translated or amended without the express written consent of DICAD Sys-

    teme GmbH.

    DICAD Systeme GmbH reserves the right to alter or revise this publication at any time without prior notice.

    DICAD Systeme GmbH accepts no liability except as set forth in its General Terms and Conditions.

    The instructions contained in this manual shall not be construed as a warranty of particular product capabilities.

  • 7/28/2019 Extension Manual 2011

    3/67

    STRAKON 1

    Contents

    Installation Instructions Version 2011 4New Features of STRAKON Version 2011 8Part 1 Basics 8

    STRAKON Products 8New Product Names 8

    STRAKON Start 8Viewer Mode 8Graphic Settings 8

    STRAKON Dialogues 9New Look 9

    User Guidance 9SmartClick 9Placing New / Moving Existing Dialogue Windows 9New Selection Option in the Dialogue Windows 10

    Filtering in Selection Menus 10Detailed Texts in the Function Toolbars 11Accelerated Selection in the Combo Boxes 11Texts with the New Space-holder 11

    Function Toolbars 12Expanded Menu Bar 12Expanded Toolbar 13

    Segments 13Create Segment Polygon > Automatically Snap to Points 13New 3D Segment 133D Model Point 13Segment and Level Administration 14Selecting the Segment Functions Using the Pointer Command C 15

    Drawing Texts 15Expanded Drawing Texts 15Create / Open Drawing Set 16

    Create Drawing Set 16Open Drawing Set 16

    Settings 17New Selection via Submenu 17Other: Help Window 17Other: Drawing Elements > Create Wall Hatching 18Save Settings 18Settings in the Windows Program Bar 18

    Material Administration 19Editing Functions 19

    Polygonal Sections 19

    Copy Section to New Segment: Segment Scale 21Quick Call Up of Editing Functions Individually Free 21Move Connection Points 21

    Interfaces 21Priamos 21

    Part 2 Formwork 22Drawing 22

    Walls 22Freehand Lines 23Multiple Lines 24Insert Elements > Center Lines/Bisecting Lines 25Template 26

    Part 3 Reinforcement 28Rebar and Mesh 28

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    4/67

    2

    Eurocode: EC2 28Anchoring Lengths and Overlap Lengths 28MV, Present MV: Displaying the Reference Point 29BR, MR: Switching off the Connection to a Reference Point 29MV Stirrup Binders: Virtual Display of Binder Type and Binder Hook Position 30Copy Reinforcement 30Project Steel Totals 30

    Rebar 30

    CV: Laying Field Corrections are Retained When Moving 30CV: Move Individually and Freely Even When Correcting the Bar Position 31BR: Thread/Couplers for From-To Bar 313D Bending Shape with From-To Leg Lengths 31BR Group: Expanded Functionality 32

    Mesh 33MV: Formwork Dimension for Bar Lengths in the Z-Direction 33CV Free: Free Definition of Laying Fields and Settings 33Settings 33MV/MR: Cut Bars in 1:1 Representation 34MV/MR: Bar Position in the Z-Direction 34Design Mesh 35Item Corrections 36

    AdHoc Reinforcement 37Putting AdHoc Reinforcement Favorites in the QuickBox 37Placing AdHoc Reinforcements Using the QuickBox 37

    Reinforcement Schedules on the Drawing 38Correct Individually Free for From-To Table 38

    Part 4 Accessories 39QuickBox with Layer Information, Macros and Buil t-in Parts (Macro) 39Variants (Macros, Buil t-in Parts (Macro), etc.) 39

    Creation with Automatic Search via Section 39Maximum Element Limits Increased 39Placing Subdetail with Reinforcement in Subdetail 40

    World Coordinates 40Inserting and Exporting Lists 40Displaying Coordinates 41

    Calculation Program for Sandwich Panel Anchors (Halfen SPA) 41Settings 42Picking off Geometrical Data 43

    Steel Construction 45Taking over Steel Construction Functions into the Toolbar 45Displaying Welding Symbols as Site Welds 46Welding Symbols Texts: Pen Weight Determines the Font Size 46New Help Windows in the Parameter Input 46

    Part 5 Element Breakdown 47Unitechnik File, Version 6.0 47

    Long File Name 47Volume 47

    Slab/Wall/Facade 47Update Individual Plate Representation 47Calculating the Segment Size and the Scale 47

    Part 6 Cube3D 49Cube3D 49

    3D Segment with Level Input 493D Model Point 51CubeViewer 52Update Cube View 55Breakdown Cube View 55Settings 56

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    5/67

    STRAKON 3

    Part 7 Import /Export 57Publish 57

    Output Parameters 57DXF/DWG Import 59Import DXF/DWG as Template 61Import Pixel Graphics 61

    Proportional Image Dimensions with Drag & Drop 61Part 8 Data Export 62

    Data Export to Priamos 62Part 9 Output 63

    Print Reinforcement Schedules 63Cover Sheet 63Parts List 63Supporter Report 63

    Print Section 63Appendix 65

    New Icons for the Toolbar 65

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    6/67

    4 Installation Instructions

    Installation Instructions Version 2011

    Contents

    Important Information 4System Requirements 4Windows Vista/7 4Initial, Parallel and Update Installations 4

    Installation 5License 6

    Version License for the Dongle 6Licensing the Modules for the Computer 6Registering the Unlock Code 7

    Important Information

    System Requirements

    Operating system: Windows XP, Vista or 7

    Screen resolution: min. 1280 x 768 pixels

    Products: - .NET runtime modules 2.0

    - Products from Microsoft

    Office >2000 (for outputting lists (reports, schedules) to Excel)

    If the setup program cannot find the .NET runtime modules and/orruntime libraries (vcredist_x86), it will offer to

    install them and you will have to perform this installation as User With Administrator Rights.

    Windows Vista/7

    To ensure that STRAKON will be able to run, the installation must not be made in the following paths: c:\Windows

    and c:\Programs .

    Initial, Parallel and Update Installations

    Initial installation

    If STRAKON is not available on the computer, or only in a version lower than 5.2, then an initial installation will be

    automatically performed. That is, unless a license has been enabled; it is automatically licensed for 10 days as a

    demo. After this, you can start STRAKON without a license in Viewer Mode.

    Parallel and update installation

    If STRAKON is available on the computer in a version 5.2 or higherand earlier than 2010, you can choose between

    a parallel or an update installation.

    Parallel installation

    As an option, the settings of an installed 2010 version can be taken over. The following are taken over:

    Plotter/printer drivers and diversion files (not STRAKONs own files), tablet configuration, screen settings, layer sets,

    colors, editor settings, Excel template files, images from the template directory, input units, text modules, title block

    data, back-up file (secur.sic), settings for data export (PPC, BVBS, etc.), default sets, translation files for the

    DWG/DXF import/export, dialogue settings for back-up levels, element breakdown (all SYS files), settings for auto-

    matic snapping to points, einbau-s.dat for PPC export, definition files for design meshes and settings from Extras >

    Settings > Other. All files are copied locally into the 2011 version.

    Update installation

    Select the version onto which you want to install the 2011 update.

    If your version is lower than 5.2, please request the STRAKON CD 5.2A, then conduct the update up to version 5.2Aand restart the installation of the 2011 version.

    We recommend you perform the installation with the user-profile set as theAdministratororUser With Administra-

    tor Rights. An update must be performed using the same user-profile as was used for the initial installation.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    7/67

    STRAKON 5

    The chosen installation path must not contain any accented letters or special characters.

    Perfect functioning is only guaranteed if the useris given full access to the installed directories and working directo-

    ries of STRAKON.

    Installation1. Select the language and accept the license agreement.

    2. Select the STRAKON product (only possible with an initial installation).

    3. Select between Update and Parallel Installation.

    With the parallel installation, you can optionally take over the settings from the 2010 version.

    4. If conducting an Update, select the existing version onto which the update is to be installed.

    As an option, you can delete the old program folder from the start menu. A new folder with the current entries

    is automatically created.

    5. As an option, a link to STRAKON 2011 can be created for you on the desktop.

    6. Continue by following the instructions in the installation dialogue prompts.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    8/67

    6 Installation Instructions

    License

    Version License for the Dongle

    No version license is necessary for the dongle in Service!

    Check the version number in the hardlock via: Start > Programs > DICAD 2011 > Test dongle protection :

    Requesting a version license for the hardlock with pre-2011 versions

    Open the license via Start > Programs > DICAD 2011 > Unlock softw are:

    Click on Request, complete the input boxes and send the request to the responsible customer services department.

    Licensing the Modules for the Computer

    You can unlock modules (e.g. Steel Construction Variants etc.) only for the computer in question via an unlock code.

    Open the license via Start > Programs > DICAD 2011 > Unlock softw are:

    Highlight the modules, click on >> and Continue, complete the input boxes and send the request to the responsible

    customer services department.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    9/67

    STRAKON 7

    Registering the Unlock Code

    Open the license via Start > Programs > DICAD 2011 > Unlock software, enter the unlock code in capital letters

    and click on Register.

    We wish you every success in all your work with the 2011 version!

    Should you have any further questions, please do not hesitate to contact us.

    Your DICAD Support Team

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    10/67

    8 New Features of STRAKON Version 2011

    New Features of STRAKON Version 2011

    Part 1 Basics

    STRAKON Products

    New Product Names

    While of course retaining their familiar, unchanged product scope, the STRAKON products have been renamed to

    make the individual product levels more easily identifiable.

    STRAKONpremium formerly: STRAKON/SSTRAKONstandard formerly: STRAKON/NP

    STRAKONlight formerly: STRAKIT

    STRAKON Start

    Viewer Mode

    If no dongle is connected to the computer, or if the necessary software license is missing, STRAKON can be started

    in Viewer mode. Viewer mode allows you to open and view drawings, to zoom into the drawings, to measure ele-

    ments and to plot the current drawing and the reinforcement reports.

    If you always start STRAKON without a dongle directly in Viewer Mode and therefore want to bypass this prompt

    window, select the option: Without Dongle, always start i n Viewer mode.

    Graphic Settings

    In the STRAKON graphic settings (Start > Programs > DICAD 2011 > Settings > Graphic settings) the optionsJoin Toolbars and Flat toolbarare switched on as default. A user-dependent setting is no longer possible.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    11/67

    STRAKON Part 1 Basics 9

    STRAKON Dialogues

    New Look

    While retaining the same user guidance and prompts, the familiar STRAKON dialogue windows have been given a

    new look. The graphic help windows have been revamped with modern images that are appealing to the eye.

    User Guidance

    SmartClick

    The familiar click function has been renamed as SmartClick.

    Placing New / Moving Existing Dialogue Windows

    By dragging the title bar you can move all dialogue windows and place them in a new location, even beyond the

    screen.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    12/67

    10 New Features of STRAKON Version 2011

    New Selection Option in the Dialogue Windows

    If the dialogue windows have any selection areas, such as with the labeling types for the re-bar, you can now also

    make the selection using theArrow keys.

    The background color of the selection area has the following meaning:

    Dark This is the (default) selection as determined in the settings

    Light, with orange border This is the current selection

    Filtering in Selection Menus

    The filter function in the selection menus for the fonts and layers has been revised. Using the Filter icon you cancontrol the columns to be searched through, whereby also partial texts will be searched (e.g. mes > Mesh). You canswitch from the filter view to the complete menu by marking and deleting the search string (Del key).

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    13/67

    STRAKON Part 1 Basics 11

    Detailed Texts in the Function Toolbars

    No more guessing what the tool bar functions are! Understandable and fully detailed texts make it easier for you to

    make inputs and selections and to call up the functions in the user prompts, e.g. in the dimension correction windows

    or in the selection menus for the rebar, etc.

    Accelerated Selec tion in the Combo Boxes

    By using the greater than/smaller than key on the keypad, you can also select (toggle function) the individual

    options without having to open the combo boxes (selection menus). E.g. to select the input type in the Rectanglesfunction,

    or to select the stirrup binder types in the stirrup binder inputs main view in the Comfort mode for reinforcement

    input

    or to select the reinforcement report to be placed in the drawing. Here you can toggle between the full list of all possi-

    ble reinforcement reports and your favorites list.

    Texts with the New Space-holder

    When copying (also copying individually), moving or loading texts, they are now always shown with a new space-

    holder box (rectangle + diagonal).

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    14/67

    12 New Features of STRAKON Version 2011

    Function Toolbars

    Expanded Menu Bar

    Accessories > Sandwich panel anchor > Halfen SPA

    TheAccessories menu has been expanded by the addition of the Sandwich panel anchor > Halfen SPA interface

    (see menu explanations:Accessor ies > Sandwich panel anchor, page 41).

    Cube3D

    The new Cube3D menu enables you to create 3D structures and to construct building sections (see Cube3D, page

    49)

    Other > Mikogo

    In addition to the Netviewerprogram, the Mikogo program is now also available (Internet presentation / support

    program).

    Extras > Colors

    In the color configuration you can use the Cross, Cross (small) and Arrow cursor displays. The separate cursor

    selection for the Toolbar is no longer available.

    ? > Modules

    The STRAKON Modules option has been discontinued.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    15/67

    STRAKON Part 1 Basics 13

    Expanded Toolbar

    The scope of selectable functions has been expanded in the Extras > Toolbarmenu by the addition of:

    Category: File >Drawing data

    Category: Side > Zoom all segments, determine zoom (all functions), e.g. Zoom all segments

    Category: Edit > Identify (various functions), e.g. Identify text point

    New functions

    (seeAppendix, page 65)

    Segments

    The selection of segment functions (see Toolbar > Extras: Segments) has been expanded for working with the func-

    tions of the new Cube3D menu (see Cube3D, page 49).

    Using the New 3D segment and 3D model po int functions, you can give the segment the necessary 3D information

    directly when creating the segment and also subsequently move the 3D model point.

    Create Segment Polygon > Automatically Snap to Points

    When creating a segment via a polygon, you can also use the Automatical ly Snap to Points function; whereby, it is

    also possible to snap to the drawing border.

    New 3D Segment

    (not in STRAKONlight)

    After entering the segment scale and name and determining the segments bordering frame, select the required level.

    3D Model Point

    (not in STRAKONlight)

    The models placement point (see Cube3D, page 49) is automatically set as the segment origin point and marked

    with a + character.

    Using the 3D model poin t function, the models placement point can be subsequently moved to any point required,

    e.g. to a building corner.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    16/67

    14 New Features of STRAKON Version 2011

    Segment and Level Adminis tration

    The segment administration has been expanded by the addition of the level administration and the dialogue window

    has been revised.

    Click on theAct ive column to highlight the segment in which you want to continue working after closing the segment

    and level administration.

    Clicking on the Name orScale column will change the segment name or segment scale. Please note: you can only

    alter the scale ofempty segments.

    The other columns and icons can be used as follows:

    Draw the marked segments, on/off

    Highlight one or several lines and switch the display of the segment contents on or off. Individual seg-

    ments can also be switched on or off directly by using the check boxes in Draw column.

    Switched-off segments are indicated in the drawing with a cross (Nplo).

    Remove level for marked segment

    The level belonging to the highlighted segments is deleted and the Cube3D export is automatically

    switched off. Segments without any level specified are identified in the Level column with the words:Not used.

    3D export of marked segments, on/off

    For highlighted segments where a level is specified, the Cube3D export can be switched on or off. The

    Cube3D export of individual segments can also be switched on or off directly by using the check boxes

    in the Cube3D column.

    Level administration

    In the level administration, define the required general or even project-specific levels by giving their

    Name (description text) and the level value (height) in the currently set input units (see Toolbar).

    To Create new level, there is a new line at the ready, marked with an astarisc *.

    Add levels f rom file

    The selected levels in the recalled level file (*.xml) are taken over into the current level

    administration.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    17/67

    STRAKON Part 1 Basics 15

    Save as

    All displayed levels are saved in an XML file (*.xml). The target path of %stra-

    kon%\niveau is offered as a default here. The saved levels can be inserted into new

    drawings/projects for further usage.

    Segment data

    The segment data of the highlighted segment (e.g. number of elements, angle of rotation and grid) is

    displayed in a further dialogue window.

    Selecting the Segment Funct ions Using the Pointer Command C

    (not in STRAKONlight)

    To save time, the options of the Segments function (see Toolbar > Extras: Segments) can also be called up by

    selecting a segment border with the Pointer Command C. The Modify fence function is preset and can be directly

    confirmed if this default is appropriate. Please note: the segment borders must be selected by moving to them from

    the inside.

    Drawing Texts

    Expanded Drawing Texts

    The name and scale of the active segment can be taken over into the segment by using the new drawing texts.

    Drawing text for the segment name: !SEG;TEXT;

    Drawing text for the segment scale: !SEG;MASS;

    Example: segment 2 is to be labeled.

    Activate segment 2, select the text function and enter the drawing texts:

    Text input: Segment: !SEG;TEXT;

    Text input: Scale: 1:!SEG;MASS;

    Result:

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    18/67

    16 New Features of STRAKON Version 2011

    Create / Open Drawing Set

    When working on your project you will want to have quick and easy-to-understand access to all necessary drawings

    at all times, even if the drawings are located in several working directories.

    You can now save time-consuming searching for and opening the individual drawings by combining and saving sev-

    eral opened drawings in a drawing set.

    Create Drawing Set

    In the Window > Show all windows menu, highlight the drawings you want to save in a drawing set and click on the

    Create drawing set button.

    The drawing set is saved in an SPS file (*.sps) and, as a default, stored in the %strakon%\sessions directory.

    Open Drawing Set

    Via the File > Open drawing set menuor in the drawing data via the new icon , select the drawing set whosedrawings (i.e. the saved statuses of the drawings) are to be directly opened. Here, the last drawing from the drawingset is displayed on the screen.

    Note:

    The status opened is always the last saved status of a drawing.

    A network path can also be selected as the storage location.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    19/67

    STRAKON Part 1 Basics 17

    Settings

    New Selection via Submenu

    In the Extras > Settings menu, the settings Other, Set selection for drawings, etc. are now selected in the ex-

    panded and reorganized submenu.

    Other: Help Window

    In the Extras > Settings > Other > Help window menu, define which help windows are to be automatically opened

    when calling up the relevant functions. TheAutomatically open help w indow option switches the automatic function

    on and off.

    Note:

    The settings for the pen selection via the help window are now also located in the Extras > Settings > Other > Help

    window > Pens menu.The old option ofSelection always via d ialogue has been discontinued.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    20/67

    18 New Features of STRAKON Version 2011

    Other: Drawing Elements > Create Wall Hatching

    (not in STRAKONlight)

    In the Extras > Settings > Other > Drawing elements menu, switch the Create wall hatching option on if you want

    to directly color the walls in the material color (see Material administration, page 19).

    Note:

    The check boxs setting does not have any retro-active effect on any existing walls.

    Save Settings

    The Save settings function has been moved from the settings selection menu directly to the Extras menu.

    Settings in the Windows Program Bar

    A new dialogue prompt has also been integrated in the Windows program bar: Start > Programs > DICAD 2011 >

    Settings. To save your settings, select the last entry in the list: Save settings.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    21/67

    STRAKON Part 1 Basics 19

    Material Administration

    In the Extras > Material Administration menu, the dialogue window has now been given a new look. The user

    prompts correspond to those of the rebar administration, i.e. To Create new material, there is a new line at the ready,

    marked with an astarisc *.

    Each material can be assigned a priority (see Drawing, Walls, page 22) and a color for the wall hatching. The se-

    quential order and the level of priority is arbitrary. To delete the materials from the administration, mark the line and

    use the Del key.

    Editing Functions

    Polygonal Sections

    The selection of section options in the editing functions (see menu Edit > Delete section, etc.) has been group to-

    gether in the combo box and expanded by the addition of the Polygon option.

    To recess any elements in the section, select Polygon.

    After entering all of the points of the polygon, end the section definition, e.g. using . An intersection of the start andend lines automatically closes the polygon. If these lines do not intersect, the section is automatically closed by aconnecting line drawn between the first and last points of the polygon.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    22/67

    20 New Features of STRAKON Version 2011

    Example 1:

    End line

    Start line

    Example 2:

    Note:

    If the section polygon is entered in clockwise rotation, then all the elements are marked without further prompting and

    you can directly choose the reference point.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    23/67

    STRAKON Part 1 Basics 21

    Copy Section to New Segment: Segment Scale

    If you copy a section into a new segment, then the drawings main scale and the sections original segment scale are

    offered as a new segment scale. The original segment scale is given as a default and, by confirming, can be directly

    taken over for the new segment.

    Quick Call Up of Editing Functions Individually Free

    The editing functions individually free can be quickly selected by pressing the Alt key and the familiar pointer

    commands forDelete section, Copy section, etc.:

    Delete individually free Al t+ pointer commandCopy individually free Al t+ Pointer commandMove individually free Al t+ Pointer command>

    Correct individually free Al t+ Pointer command

    The starting point for the pointer command determines the element to be edited.

    All other pointer commands for the editing functions individually free, such as ~ or C etc. are retained.

    Move Connection Points

    (not in STRAKONlight)

    When making changes to the geometry or the display, the Edit > Move connection points menu can be used to

    move the connection points (e.g. of the hatching, reinforcement, dimensions and polygon) anywhere about a Sec-

    tion, Polygon or a Segment. E.g. reinforcement

    Select point 1, 2

    Section

    Using Section orApp ly move to all po ints in the additional function toolbar, you can optionally also move selected

    connection points or all highlighted connection points by the same amount all in one go.

    The connection points are shown as a small square. Move to the required points to select them and then stipulate

    their new position. The reinforcement is automatically adjusted to suit the new coordinates.

    Note:

    You can undo the Move connection points operation using theUndo function!

    Interfaces

    PriamosUsing the File > Interfaces menu, you can export your drawing data as a calculation file to the Priamos interface

    (see Data expor t, page 62).

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    24/67

    22 New Features of STRAKON Version 2011

    Part 2 Formwork

    Drawing

    Walls(not in STRAKONlight)

    Changing the Position of the Wall Line Using Additional Key Combination

    You can change the position of the wall line by pressing the B key (capital letter) or by using the keyboard shortcut

    Shift+ .

    Wall Input Using a Rectangle

    The selection of the wall input functions (see menu Draw > Building Components >Walls) has been brought to-

    gether in the combo box and expanded by the addition of the Rectangle option.

    This input function makes it possible to quickly and easily create a closed, rectangular wall polygon. In addition to

    stretching a rectangle, it is also possible to confirm the first point of the rectangle and then to immediately specify the

    size of that rectangle by entering the X and Y values, e.g. 150,500.

    Individually Copy Wall Rectangle

    Immediately after placing a wall rectangle in the drawing, you can copy it using the Edit > Copy Individually func-

    tion.

    Priority-dependent Creation of Wall ConnectionsIn obvious wall situations (wall corners, wall intersections, etc.), you can define the automatically created wall con-

    nections in a priority-dependent manner, e.g. according to concrete grades. For this purpose, the Priority column

    has been added to the Extras > Material Administration menu.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    25/67

    STRAKON Part 2 Formwork 23

    The higherpriority decides on which will be the continuous wall, e.g.:

    Concrete grade C25/30 > Priority 60

    Concrete grade C16/20 > Priority 20

    Concrete grade C16/20 > Priority 20

    Concrete grade C25/30 > Priority 60

    Note:

    As alternative to repeatedly selecting the wall attributes via the Material Administration, you can also predefine

    frequently used wall elements and save them in theAccessories >QuickBox menu (see STRAKON Help).

    When taking over the wall elements into the QuickBox, the material and its settings are also saved with it.

    If the abutting walls are of different material and you change this to the same material, the wall connections must

    then be changed manually.

    Freehand Lines

    (not in STRAKONlight)

    Freehand lines are now entered by pressing theAlt GrorCtrl+Alt key and drawing with the left mouse key. When

    doing this you can also use all the familiar pointer commands, e.g. for zooming into the section, ending (terminating

    the function), etc.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    26/67

    24 New Features of STRAKON Version 2011

    Multiple Lines

    Parallel double lines and multiple lines can be entered quickly and simply either individually or as a polygon. These

    parallel lines can then be closed of at the ends if required, e.g. to form walls.

    Double Lines

    Two parallel lines are simultaneously drawn using the Double lines function.

    In the additional function toolbar, select the line polygon, the line style and the pen weight, and also specify the input

    line (left, right, middle) analogous to the line/wall input. In addition, define the Spacing between the two lines.

    The Terminating line option for the two end faces allows closed building components to be displayed in the plan,

    e.g. walls etc. Line connections are automatically created at the obvious corner points of the lines.

    Multiple Lines

    The Multiple lines option allows you to create parallel lines simultaneously.

    In the additional function toolbar, select the line polygon and, if necessary, the Terminating line option for the end

    faces. The clearance between the lines, the line style and the pen weight as well as the reference line for the position

    of the lines are all defined using the settings (>>).

    Here, the reference line has the position 0.00, in the example this is the middle line. The position of all further lines is

    entered via the Clearance or the Position. The corresponding values are directly recalculated. Line connections are

    automatically created at the obvious corner points of the lines.

    When entering the lines, you can change the reference line using the keyboard shortcut Shift+ .

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    27/67

    STRAKON Part 2 Formwork 25

    Important!

    The last input of a line (double or multiple line) can be undone using the Edit > Delete last input function.

    Insert Elements > Center Lines/Bisecting LinesThe input helps that act as design-aids have been expanded by the addition of the elements: Centre lines and Bi-

    secting lines.

    Center Lines

    The Center lines option enables the input of up to 99 lines arranged in a fan formation between two existing lines.

    In the additional function toolbar, select the line style, the pen weight and the quantity of center lines to be inserted

    (max. 99). The start and end points of the center lines are defined by the lengths of the initial two lines.

    Center lineCenter lines

    Quantity = 1 Quantity = 5

    Bisecting Lines

    The Bisecting lines option enables the input of up to 99 lines that bisect the angle and are arranged in a fan forma-

    tion between two existing lines.

    In the additional function toolbar, select the line style, the pen weight and the quantity of bisecting lines to be inserted

    (max. 99). The start and end points of the bisecting lines are derived from the theoretical intersection point (M) and

    from the lengths of the initial two lines.

    yBisecting line Bisecting lines

    Important:

    The last input of a line (center line or bisecting line) can be undone using the Edit > Delete last input function.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    28/67

    26 New Features of STRAKON Version 2011

    Template

    (not in STRAKONlight)

    As design aid for the current editing, you can use Templates (drawing sections) either in the same drawing and/or

    from another drawing or a DXF/DWG file.

    Templates allow you to trace existing drawing elements such as lines, circles, rectangles etc., but not texts, dimen-sions and hatching. For this purpose, the drawing elements of the template are shown in only one pen weight and in

    the line style 1 and this cannot be changed. It is not possible to attach or link other elements such as reinforcement,

    hatching etc. to the template elements.

    Template New plan view

    A template can be created and placed in the drawing either in reusable or temporary format (i.e. only created and

    placed once) or it can be directly placed from a DXF/DWG file. For the reusable format, select Create, define the

    template content and save it in a SCA file (*.sca). The name of the drawing is offered to you as a file name and the

    directory %strakon%\templates as the target directory.

    The placement of a template from a DXF/DWG file is a quick and easy input method and always includes all the

    drawing elements of the file (e.g. lines etc.), but there are no prior selection options. The conversion factor is fixed as

    1.

    The placement of the template is done to scale but is independent of segment and layer, whereby you can optionally

    select a scaling factor, an angle of rotation and a different pen weight. After placement, you can move the template

    wherever and whenever you want using the Move Individually Free editing function.

    All the templates placed in a drawing are displayed in the list. After completing various drawing sections or the entire

    drawing, you can delete the previously placed templates either all in one go using the Delete all option or individually

    using the Delete Individually Free editing function. You can recall a deleted template using the Undo function (Re-

    do/Undo).

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    29/67

    STRAKON Part 2 Formwork 27

    Note:

    When placing a template, a maximum of 500 elements are shown on the cursor. All the elements will only be dis-

    played after completing the placement.

    Placed templates are not saved with the drawing or in a backup. Templates are deleted when a drawing is closed.

    Any templates present in a drawing are ignored when outputting (plotting) and when exporting data.

    The placement of a template from a DXF/DWG file is made using the standard settings of the DXF/DWG import. It

    is not possible to modify the imported file contents.

    An extended template creation with all the familiar options of the DXF/DWG import is offered by the menu: File >

    Import/Export>Import DXF/DWG as Template (see explanation in Part 7, page 57).

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    30/67

    28 New Features of STRAKON Version 2011

    Part 3 Reinforcement

    Rebar and Mesh

    Eurocode: EC2

    Basis of Calculation as per Eurocode

    The basis of calculation for rebar and mesh according to Eurocode and the new rebar administration set EC2 (steel

    grades B500A, B500B) have both been integrated into STRAKON.

    The required basis of calculation is selected in the Rebar/Mesh settings > General settings > Reinforcement set-

    tings.

    Important!

    When a STRAKON update is made, the basis of calculation is set to Eurocode EC2 regardless of the selected

    rebar set.

    Take note: the setting of the required basis of calculation is made independent of the selected rebar/mesh ad-

    ministration set. The administration set required for editing the drawing is still selected as before in the Rebar

    and/or Mesh Administration.

    Anchor ing Lengths and Over lap Lengths

    The figures given in the dialogue window for the anchoring lengths and overlap lengths are made in accordance with

    the selected basis of calculation (see above explanations), e.g. to EC2:

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    31/67

    STRAKON Part 3 Reinforcement 29

    Calculating the Overlap Lengths and Anchoring Lengths Using Formula

    If the bar length in the main view (MV) exceeds the maximum bar length, the lengths of overlap or anchoring can alsobe calculated using the relevant variables (in a formula) in the reinforcement input modes Comfort orQuick. The

    following variables are available for this:

    lb = Lb,rqd

    le = LB,eq

    ld = Lbd,dir

    li = Lbd,ind

    l0 = l0

    Example:

    Input: li + le - ld

    MV, Present MV: Displaying the Reference PointIf you want to place the view of a piece of reinforcement into a drawing again (e.g. using the rebar function Present

    MV), the selection bar directly shows the relevant reference point, identified by a cross.

    BR, MR: Switching off the Connection to a Reference Point

    It is now also possible to place bar representations/mesh representations (BR/MR) without having a connection to the

    formwork (e.g. for placing in another segment). The size of the representation is automatically adjusted to suit the

    scale of the actual segment.

    The connecting link to the reference point is switched on or off using the Ref po int option in the additional function

    toolbar. Alternatively, the connection can also be switched off via End/Continue during the reference point prompt.

    Unlinked bar representations/mesh representations are given a virtual connection point (small circle = hook) on the

    bar starting point to facilitate further editing, e.g. position correction etc.

    >Reference point (switched on) Reference point (switched off)

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    32/67

    30 New Features of STRAKON Version 2011

    MV Stirrup Binders: Virtual Display of Binder Type and Binder Hook Posi-tion

    When entering the binder in the reinforcement input modes Comfort and Quick, the type of binder and the position

    of the binder hooks are displayed virtually.

    Copy Reinforcement

    The reinforcement copied using the Reinforcement > Copy reinforcement menu (see STRAKON help) can now be

    repeatedly placed in a drawing. Before placement, the reference point can be changed using Shift+B orShift+ .

    Note:

    It is now also possible to copy main views of mesh.

    Project Steel Totals

    (not in STRAKONlight)

    The project steel totals report that is integrated into the Reinforcement menu now also contains the weight of the

    prestressing steel and the gross weight of the individual mesh types (standard, special list, design mesh) and also

    states all the mesh types used.

    Note:

    The Excel template file DICADStahlmassen.xls is located in the strakon\ExcelVorlagen directory and must be

    altered to suit the required company title block data.

    Rebar

    CV: Laying Field Corrections are Retained When Moving

    If you change the geometry of a laying field by moving (Menu: Edit > Move section (individually f ree)) in the Bar

    direction, then any corrections made to the laying field are retained (repositioning, deletion, insertion). The same

    also applies to the Move points option, e.g.:

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    33/67

    STRAKON Part 3 Reinforcement 31

    Bar direction

    Laying line

    CV: Move Individually and Freely Even When Correcting the Bar Position

    You can now correct the position of the bar in the count view using the editing function Move individually free with-

    out having to call up the correction function CV > Quanti ty, spacing > Position.

    BR: Thread/Couplers for From-To Bar

    (not in STRAKONlight)

    In the bar representation, the threaded connections thread and couplers can now also be defined for the from-to

    bar function as well.

    3D Bending Shape with From-To Leg Lengths

    Bending shapes with bar legs in the Z direction (e.g. D2 shape support stirrup or corbel bar) can now also be exe-cuted with variable leg lengths (from-to bar).

    The from-to legs are laid in the count view usingA-Leg (area leg).

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    34/67

    32 New Features of STRAKON Version 2011

    Note:

    If you create a variable bar of the bending shape D2 without a main view, for the Display in the bar representation it

    will then be necessary to initially enter the variable legs in the input window with a constant bar length. The adjust-

    ment of the true from-to leg lengths will then be made when positioning the item in the drawing.

    BR Group: Expanded Functionality

    (not in STRAKONlight)

    When entering bar representations using the BR group function, you can choose between the Symbolic represen-

    tation (>BR symbol group) and the display to scale (BR symbol group).

    Symbolic representation Display to scale

    Note:

    In the BR group function, it is also possible to place bar representations into the drawing to scale without having a

    connection to the formwork (e.g. for placing in another segment) (see BR, MR: switching off the connection to a

    reference point, page 29).

    Only consider items without BR

    This is for checking your drawing for any missing bar representations. Regardless of the selected display type (to

    scale or symbolic), the new function BR group > Only items without BR allows all the missing bar representations

    of an item range to be created in one step.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    35/67

    STRAKON Part 3 Reinforcement 33

    Mesh

    MV: Formwork Dimension for Bar Lengths in the Z Direction

    (not in STRAKONlight)

    It is now also possible to define the mesh lengths/widths in the Z direction by entering the Formwork dimension, as

    is familiar with the rebar,or by using the From formwork option.

    CV Free: Free Definition of Laying Fields and Settings

    (not in STRAKONlight)

    Free Definit ion of Laying Fields

    In the reinforcement in the Comfort orQuick mode, you can enter items such as edge rebar and additional rebar

    quickly and easily using freely defined laying fields.

    After calling up the CV free function, in the additional function toolbar select the mesh type, the quantity of mesh to

    be laid and the mesh dimensions and butts.

    The placement options and correction possibilities can be used analogously to the familiarCV individually function.

    To determine the free mesh position, the load-bearing direction is shown in line style 2 and the transverse/load-

    distributor in line style 3. For the laying field, Nplo lines are automatically created

    Settings

    The settings selected here are linked to the global settings in the mesh function.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    36/67

    34 New Features of STRAKON Version 2011

    MV/MR: Cut Bars in 1:1 Representation

    In the 1:1 representation of main views (MV) and mesh representations (MR), the cut bars of the mesh are now also

    shown.

    Depending on the chosen position (Left/Right looking towards the input line), the cut bars will lie inside or outside onthe mesh bar. The amount of concrete cover is always maintained here.

    The arrangement of the cut bars corresponds to the specifications from the Mesh Administration and starts at the first

    polygon point of the mesh bar.

    Note:

    The position of the cut bar (inside/outside) can be changed during the input using the Shift+ orShift+B keys.

    MV/MR: Bar Position in the Z-Direction

    You can correct the bar position (Left/Right) in the Z-direction for the symbolic representation in the Mesh Represen-

    tation (MR) and for the 1:1 display in the main view (MV) during the input by using the Left/Right option (toggle func-

    tion), e.g.

    MR via bending shape (withou t MV):

    MV stirrup binder in the Comfort reinforcement input mode:

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    37/67

    STRAKON Part 3 Reinforcement 35

    Note:

    The position of the cut bar (inside/outside) can be changed during the input using the Shift+ orShift+B keys.

    Design Mesh

    MV: New Polygon Inputs and Correction Options

    (not in STRAKONlight)

    When inputting a new design mesh in the main view (MV), the layout and position of the cut bar are now directly

    shown for you regardless of the type of display (Normal, Rnd , 1:1) and then offered for correction.

    The initially displayed layout and position of the bar are a result of the specifications of the bar and mesh definitions.

    Note:

    If the display type 1:1 is selected for this, then the cut bar will also be displayed in the finished main view (see previ-

    ous explanations, page 34).

    After selecting the bent wire (load-bearing/load-distributing wire, single/double wire, wire diameter), select the posi-tion of the cut bar (left/right looking towards the input line) in the additional function toolbar and enter the polygon, the

    mesh width, the type of display (in the example: 1:1) and the mesh definitions.

    The layout and the position of the cut bar can then be edited using the new correction bar. The arrow symbol shows

    the starting point of the bending shape.

    Individually posit ion, delete, insert

    For deleting, adding or moving the position of individual bars.

    Using the function Individually position, it is only necessary to input the distance (Attention: minus sign necessary

    for negative X or Y direction) in the selected input units (see Toolbar) measured from a formwork edge point or froman identifiable bar (via the Z key). The bar is automatically re-laid on the mesh wire.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    38/67

    36 New Features of STRAKON Version 2011

    Distance

    Re-specifies the spacingand/orquantity of cut bar (in the input unit shown). In this case, the overhangs (O1, O2)

    are retained and the bar spacing is adjusted accordingly.

    If you additionally switch on the Distribute option in the additional function toolbar, the bar spacings will be retained

    and the overhangs will be uniformly adjusted.

    It is also possible here to enterquantity,spacing, whereby the bar laying is made starting from the first overhang, inthe example 25,15 (cm)

    Overhang

    The two Overhangs (O1, O2) at the start and end of the mesh are (in the input units shown) re-specified, in the ex-

    ample 10,20 (cm). The bar spacing is retained here, whereby the last cut bar may be omitted.

    Mirror

    The laying of the cut bar is mirrored within the mesh, i.e. the laying direction is swapped over.

    Original

    The laying of the cut bar is reset to its original status, i.e. to the specifications in the bar and mesh definitions.

    Continue

    The correction of the cut bar is ended and the familiar design mesh editor is opened.

    Item Corrections

    Correcting the Item Number: Close Gaps

    The mesh function now also allows you to close all the gaps in the item numbering for the current drawing in one

    step using the familiarItem correction > Item number.

    The items are renumbered so that each smallest free item is replaced by the next highest item number.

    Note:

    This correction can be reversed using the Undo function in the icon bar.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    39/67

    STRAKON Part 3 Reinforcement 37

    AdHoc Reinforcement

    Putting AdHoc Reinforcement Favorites in the QuickBox

    (not in STRAKONlight)

    The Derivation f rom sample function is replaced by the new name AdHoc reinforcement. For quick access to the

    drawing elements, you can now also put AdHoc reinforcements in the QuickBox (Menu: Accessor ies > Quick-Box, see STRAKON Help).

    For daily use in your office, STRAKON offers you the most widely used standard templates of AdHoc reinforcement.

    Placing AdHoc Reinforcements Using the QuickBox

    (not in STRAKONlight)

    You can place theAdHoc reinforcements from the QuickBox into the drawing using the Comfort input mode (quick

    coordinate input using the contour search cursor) and also, without answering any further prompts, using the addi-

    tional option: Quick. The Classic input mode also remains available, e.g.:

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    40/67

    38 New Features of STRAKON Version 2011

    If you want to place the AdHoc reinforcement into the drawing even quicker (i.e. with very few prompts), then switch

    the Quick option on in the Comfort input mode. In this case, the pre-specified diameter and the pre-specified con-

    crete cover thicknesses are both directly taken over and the automatic main view item comparison is executed.

    Polygon point 1 Polygon point 2

    Here, the formwork geometry is always searched for in the direction of the selected line (arrow labeling), whereby the

    next closest formwork edge point is the starting point for the placement of the reinforcement (point labeling). The

    contour search cursor is automatically rotated to the direction of the selected line.

    Note:

    When searching the formwork geometry, if possible, the contour search cursor and therefore the reinforcement as

    well are automatically mirrored.

    Reinforcement Schedules on the Drawing

    Correct Individually Free for From-To Table

    You can quickly correct the position and/or the appearance of the from-to table using the icon or the PointerCommand C on or rather in the table.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    41/67

    STRAKON Part 4 Accessor ies 39

    Part 4 Accessories

    QuickBox with Layer Information, Macros and Built -in Parts

    (Macro)(not in STRAKONlight)

    With immediate effect, the layer information of the drawing elements (lines, circles, rectangles, dimensions, datum

    levels, texts, hatching, walls and columns) are also saved when taken over into the QuickBox. Using the New from

    administration icon, you can additionally also take over the macros and the Built-in Parts (macro) into the QuickBox.

    Variants (Macros, Built-in Parts (Macro), etc.)

    Creation with Automatic Search via Section

    Analogous to the editing functions Move, Copy, etc., via section, you can similarly define the search area of the sub-

    details when creating macros, built-in parts, etc.

    The search via all elements of the subdetail is performed automatically when the section is stretched around an

    area from top to bottom (Quick section):

    If the search section is stretched from bottom to top, the manual search functions and the correction dialogue window

    of the subdetail selection (SD selection) will be available as usual:

    Note:

    If only one subdetail is created using the Quick section function, the SD selection correction dialog window will be

    omitted.

    Maximum Element Limits Increased

    The maximum element limits have been increased as follows:

    Coordinates : 3000Lines : 2500

    Dimensions : 1500

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    42/67

    40 New Features of STRAKON Version 2011

    Placing Subdetail with Reinforcement in Subdetail

    If the subdetail to be placed contains any reinforcement, the following subdetail variables will be available:

    TxxyyBnr = 0 The reinforcement is not placed

    TxxyyBnr = 1 The reinforcement is placed immediately

    TxxyyBnr = 2 The reinforcement is placed later

    World Coordinates

    Inserting and Exporting Lists

    The world coordinates defined in the drawing can now be placed directly into the drawing as a list or exported to

    Excel as a list.

    The lists are called up in theAccessor ies > World Coordinates menu.

    Insert Schedule

    The world coordinates list is placed in the drawing using the familiar list options.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    43/67

    STRAKON Part 4 Accessor ies 41

    Exporting List to Excel

    For further use, the world coordinates of the drawing are exported to Excel as an XLS file (*.xls). The

    DICADWKSLISTE.xls file in the strakon\ExcelVorlagen directory is available for you as a template file for this.

    Displaying CoordinatesIn the selection menu opened via the Accessor ies > World Coordinates > Ind ividual menu, you can select the

    following options for displaying the world coordinate points: Single-lined , Double-lined , Number (only the point

    number), Single-lined with numberorDouble-lined with number.

    In addition, in the additional function toolbar define the Start numberand, if necessary, a headertext.

    Calculation Program for Sandwich Panel Anchors (Halfen SPA)

    Start the HALFEN calculation program for sandwich panel anchors (Version >3.32) via the menu: Accessor ies

    > Sandwich Panel Anchor > Halfen SPA.

    The prerequisites for the calculation are that there is a sandwich panel drawn in the current drawing, that the calcula-

    tion program from HALFEN (www.halfen.de) is installed and that the correct settings have been made.

    The interface is the link from STRAKON to the sandwich panel anchor calculation program version 3.32 or higher

    from the HALFEN company. Transfer the geometry of your drawn sandwich panel to the calculation program, then

    have the necessary anchors and pins calculated and, finally, as an option, have them placed in your sandwich panel

    in STRAKON.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    44/67

    42 New Features of STRAKON Version 2011

    Settings

    Before picking the points from the geometry, open the Settings menu and enter the necessary data.

    Paths

    Path of the calculation program

    Select the path including the name of the calculation program using the button.

    Path of the transfer file

    Select the path including the file name of the transfer file. This file not only transfers the geometrical data to the calcu-lation program, but also returns the calculated anchors and pins to STRAKON. The drawing name is automatically

    offered as the file name.

    Geometry

    Select the layer thicknesses and concrete cover thicknesses for the current sandwich panel.

    Other

    For the exterior layer, the color and the rotational information are also required.

    If the interior and exterior layers have identical geometries, switch the option on. The selected geometry of the

    interior layer is internally copied for the exterior layer.

    Switch the Place item text function off if you do not want to have any item text on the pins and anchors that areplaced in STRAKON.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    45/67

    STRAKON Part 4 Accessor ies 43

    Picking off Geometrical Data

    Interior layer orexterior layer

    Opening

    Strengthening =window

    Strengthening =corner amplif.

    Strengthening = exterior layer

    Strengthening =insulation layer

    Interior Layer/Exterior Layer

    Select the corner points of the outer geometry one by one. The points can be chosen going round in any direction(either clockwise or counter-clockwise) and any point can be chosen as the first point. The interior and exterior layers

    may consist of n corner points.

    If the exterior layer has the same geometry as the interior layer, then, to simplify the inputs, you can switch on the

    Interior and exterior l ayers identical option in the settings. The Function Toolbar will then no longer offer the exte-

    rior layer for picking.

    Opening

    You can pick the geometry of any number ofopenings as a rectangle via two points (diagonals).

    Strengthening

    Strengthening can be defined here.

    Select the type of strengthening:

    Exterior layer This is a strengthening on the visible side of the exterior layer

    Insulation layer A strengthening within the insulation layer. This is located on the exterior layer and can extend to

    just before the interior layer as a maximum.

    Corner amplifi-

    cation

    A strengthening as a corner reinforcement. The contour of the interior layer is executed at a cer-

    tain distance around this strengthening.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    46/67

    44 New Features of STRAKON Version 2011

    Window Strengthening around a window. This is located on the exterior layer and can extend to just be-

    fore the interior layer as a maximum.

    For the strengthening, you will also need to define the Thickness and confirm the input with Take over settings.

    Calculated

    Use the Calculated function tostart the calculation program from the HALFEN company.

    If you do not make any changes to the geometry, the openings or the strengthening, select Recalculate and transfer

    the calculation data to STRAKON using the DICAD button.

    2. Transfer

    1. Recalculate

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    47/67

    STRAKON Part 4 Accessor ies 45

    The calculated anchors and pins can now be placed immediately into the drawing.

    To simplify the placement, the sandwich panels geometry is shown virtually on the cursor. The lines of the geometry

    are not redrawn however.

    Note:

    The calculation program is available for downloading from the HALFEN company website (www.halfen.de).

    The instructions for using HALFENs calculation program can be obtained from the respective help functions.

    Steel Construct ion

    Taking over Steel Construc tion Functions into the Toolbar

    Take over the steel construction functions (see menu:Accessories > Steel Construction Var iants/Design ) into the

    Toolbar (see menu: Extras > Toolbar > Accessory category).

    Steel construction variants

    Steel construction design

    Activating the functions will open the relevant context menu where you can select the required steel components etc.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    48/67

    46 New Features of STRAKON Version 2011

    Displaying Welding Symbols as Site Welds

    Via theAccessories > Steel Construct ion > Welds menu, you can optionally switch the supplementary symbol for

    the site weld in the welding symbol on or off.

    Welding Symbols Texts: Pen Weight Determines the Font Size

    The font size (text height) is automatically adjusted here too by selecting the pen weight.

    New Help Windows in the Parameter Input

    In various input dialogue windows, the ? icon (in the title bar) can be used to open help windows containing clear

    information on parameters, e.g. node plates.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    49/67

    STRAKON Part 5 Element Breakdown 47

    Part 5 Element Breakdown

    Unitechnik File, Version 6.0

    Long File NameThe file name can now be a maximum of20 characters long.

    Volume

    The net volume is now output in SLABDATE in dm3.

    Slab/Wall/Facade

    Update Individual Plate RepresentationIf you want to update your existing individual plate representation with changed settings (e.g. reinforcement specifica-

    tions, built-in parts or title block symbol), then select Update IPR (Individual Plate Representation).

    Note:

    Any drawing elements inserted manually in the Individual Plate Representation will be deleted when the Update IPR

    function is executed.

    Calculating the Segment Size and the Scale

    Consider Title Block

    Switch the title block off if it is to be ignored when calculating the necessary segment size or segment scale.

    Title blockswitched on

    Title blockswitched off

    Calculated size Calculated size

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    50/67

    48 New Features of STRAKON Version 2011

    Placement Options

    The following options are available when placing the elements in the drawing:

    Keep scale 1:xx and segment si ze

    The scale and segment size specified in the settings are used. This may mean that the drawing content protrudes

    beyond the segment border.

    Keep scale 1:xx

    The scale specified in the settings is retained. The segment size calculated on this basis may be larger than the set

    segment size.

    Keep segment size

    The segment size specified in the settings is used and the scale calculated on that basis is displayed.

    Input 1:xx

    Enter a scale for the drawing. The segment size calculated from this cannot be less than the segment size specified

    in the settings.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    51/67

    STRAKON Part 6 Cube3D 49

    Part 6 Cube3D

    Cube3D

    (not in STRAKONlight)

    Cube3D enables you to create 3D structures and construct building sections, e.g.:

    All building components (walls, columns, ceilings) drawn in STRAKON can be taken over into the new Cube3D

    menu, where they can be displayed, sectioned and exported into the STRAKON drawing. The following requirements

    are necessary for this:

    3D Segment with Level Input

    The desired building components are drawn directly in 3D segments, i.e. via the segment function in the Toolbar >

    Extras: Segments menu

    you create beforehand a New 3D segment with scale, segment descriptive text and level input. The 3D model point

    is automatically put in the segment origin point and identified by a cross. The 3D model point serves as the segments

    reference point for stacking up the building components.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    52/67

    50 New Features of STRAKON Version 2011

    Note:

    You can also convert an existing 2D segment into a 3D segment, whereby the assignment of the level and the 3D

    model point can also be done subsequently via the segment function in Toolbar > Extras: Segments > Segment

    admin. & level admin.

    After entering the new segment, you are prompted to select the level, e.g.:

    The segments and the levels belonging to them are managed in the new Segment and level administration

    In addition to the familiar segment functions such as draw segment and scale, you can also assign the level to an

    existing segment here by clicking in the Level column.

    The following functions are also available via the icons:

    Draw the marked segments, on/off

    Remove level for marked segments

    The level is set to: Not used.

    3D export o f marked segments (with level reference), on/off(see CubeViewer, page 52)

    Level administration

    For creating, opening and saving level information about the current drawing.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    53/67

    STRAKON Part 6 Cube3D 51

    For further use (i.e. by clicking in the line), you can create various levels for the current drawing here,

    which you then assign to the desired 3D segment.

    Using the icons you can Add levels from an existing fi le and Save the level administration as an

    XML file (*.xml).

    Segment data

    3D Model Point

    You can assign the 3D model point to any segment and place it in that segment. In the CubeViewer (see CubeVie-

    wer, page 52), the segments are then placed via the 3D model point and set above each other in accordance with

    their level.

    Material administration

    The prerequisite for displaying the building components in the CubeViewer (see CubeViewer, page 52) is that the

    density [t/m3

    ] and the color are specified in the Material Administration (see STRAKON Help).

    Wall connections are automatically created here according to the chosen priority (see Priority-dependent creation

    of wall connections, page 22).

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    54/67

    52 New Features of STRAKON Version 2011

    CubeViewer

    In the CubeViewer, the building components contained in the 3D segments are displayed with the current settings

    from the Segment admin. & level admin. and the Material administration.

    Icon Bar

    The following functions are available via the integrated icon bar:

    Export into drawing

    The model is taken over into the STRAKON drawing in whatever is its current display (view, section).

    To do this, select the desired segment in the drawing and place the model; an angle of rotation and/or

    a scaling factor may be included as an option. The models lines (pens, line styles) are displayed using

    the settings for Cube Element/Views (see Settings, page 56).

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    55/67

    STRAKON Part 6 Cube3D 53

    Sectioning

    Firstly, the model is rotated in its entirety in the plan view.

    In the following explanations, six section planes are defined and the result is then displayed in an iso-

    metric view in the CubeViewer. During the entire sectioning process, this is identified by a cross-hair

    cursor. Determine the section width using two points

    Define points 1 and 2 using the cursor. As a default, point 2 is entered at right angles to point 1. If an

    angled section is required, the right angle default can be switched off with the r key.

    Then determine the viewing direction and viewing depth by stretching the window section using the

    cursor.

    The model is then rotated into the sectional view.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    56/67

    54 New Features of STRAKON Version 2011

    Determine the section height (top and bottom edge) by stretching the box around it using the cursor

    The order in which this box is stretched (whether from top to bottom or vice versa) is immaterial.

    The model is then displayed with the chosen sectioning and rotated into the isometric view.

    Display whole modelThe sectioning is deleted, the whole model redisplayed and rotated back to its original position.

    Zoom +, Zoom -

    The display of the model is increased or decreased a step at a time.

    Select display mode

    Select various display modes for the view in the CubeVieweronly:

    - Visible lines

    - Hidden lines

    - Without lines, material

    - Visible lines, material (default setting)- Hidden lines, material

    - Wire model

    Note:

    For the display of the model in the drawing, see Export to the drawing, page 52 .

    Material-based volume/weight calculation

    Allows you to calculate the material-dependent building volume (m3) and the building weight (t) directly

    in the CubeViewer.The values are listed in the relevant dialogue window.

    For further use, these can be copied and inserted into an Excel table etc. using Cut/Paste Ctrl+C/V.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    57/67

    STRAKON Part 6 Cube3D 55

    Cube Contro l

    The Cube control is used for rotating the elevation of the model into the desired viewing direction.

    To do this, click on the individual facets of the Cube and the view is instantly redisplayed,

    rotated accordingly. The automatic rotation of the cube offers additional viewing possibili-

    ties.

    Further Control Options in the CubeViewer

    For adjusting the display and position of the model in the CubeViewer, the familiar STEAKON functions are also

    available here in the CubeViewer, e.g.:

    Panning

    Arrow keys

    Image up/down

    Shift + Arrow keys Rotates model

    Moves model using the Ctrl key + left mouse button

    Moves view step by step

    Zooms in/out (larger/smaller)

    Update Cube View

    After altering the geometry of a building component, one or all the Cube Views in a drawing can be updated in one go

    using the Update Cube View option.

    After selecting one Cube View or after switching on the Update all cube views option, the model is recalculated and

    the selected Cube Views are updated.

    Note:

    For any linked elements such as reinforcement for instance, free coordinates are automatically created. These can

    be edited using the menu: Edit > Move connection points .

    Breakdown Cube View

    The Breakdown Cube View option allows you to breakdown one or all the Cube Views in the drawing in one go.

    After selecting one Cube View or after switching on the Breakdown all cube views option, the model is converted

    into a normal 3D line group that can no longer be updated.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    58/67

    56 New Features of STRAKON Version 2011

    Settings

    The CubeView settings in the drawing are defined using the Settings option.

    Display Hidden Lines in Cube View

    This switches the display of hidden lines on and off when placing the Cube View in the drawing.

    The hidden lines are placed in the drawing using the pen/line style that you defined in the settings window (see fol-

    lowing explanations).

    Use Pen Settings

    This switches the pen settings from the Settings for cube elements Cube Views dialogue window on and off.

    If this option is switched off, the Cube View is displayed using the colors and line styles that were set in the Extras >

    Pens menu.

    Section Lines, Visible Lines, Hidden Lines > Pen, Line Style

    Pen/line style settings for the various lines.

    Other

    The Otheroption allows you to continue to execute the familiar STRAKON functions 3D general, 3D wall and 3D

    reinforcement as before.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    59/67

    STRAKON Part 7 Import/Export 57

    Part 7 Import/Export

    Publish

    (only in STRAKONpremium)

    Select Publish in the File > Import / Export menu, if you want to export several output files, such as KON, PDF,

    DWG, PLT, PPS etc. all in one go from one or more drawings or from the reinforcement reports of one Working Di-

    rectory.

    Output Parameters

    Path

    Enter the export path directly or select it by clicking in the line and clicking on the button from the file selection dia-

    logue window.

    When entering the path, you can use the identifiers of the drawing data texts as well as the Windows system variable:

    %userprofile%, whereby %userprofile% stands for the profile path of the active user, e.g. c:\Documents and set-

    tings\John Sample orc:\User\John Sample.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    60/67

    58 New Features of STRAKON Version 2011

    File name, file extension, file format

    When entering the File name you can use the identifiers of the drawing data texts as well as a combination of several

    drawing data texts, e.g. !1!26 or just part of a drawing data text, e.g. !1[1:10] .

    It is not necessary to include the file extension in the file name.

    For the output of the HP-GL/2 file, select the File extension via the selection menu. Extensions not offered here can

    be directly entered in the box.

    For the output of the calculation file, select the File format beforehandvia the selection menu.

    Standard file name

    If no new file name is defined, the Standard file name will be used as a default in the PPS data export. This stan-

    dard file name is generated from the drawing data texts, such as: Building section, etc.

    Settings

    Some settings dialogue windows can be opened by clicking on . The necessary check boxes for the Output

    (printing) can be directly selected here however.

    PDF: color

    If the PDF output is to be in color, select the check box.

    The PDF files are output using the newly installed output devices PDF mono and PDF colo r.

    HP-GL/2: color and output devices

    If the HP-GL/2 output is to be in color, select the check box.

    The output is made using the selected output devices. In STRAKON versions 2011 and higher, these are set as a

    default with the newly installed devices HPGL mono and HPGL color.

    Note:

    The definition of the paths, file names or the selected settings are only saved here for the Publish function.

    In STRAKON versions 2011 and higher, the output devices installed by STRAKON (PDF mono, PDF color,HPGL mono and HPGL color) are available to you in every print function. These output devices and the assigned

    standard* drivers should not be changed because they are overwritten with every STRAKON update.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    61/67

    STRAKON Part 7 Import/Export 59

    DXF/DWG Import

    The dialogue window and the user prompts of the DXF/DWG import have been adapted to suit STRAKON Version

    2011.

    When calling up the DXF/DWG import function in the File > Import / Export menu, you now have to first select the

    DXF/DWG file.

    The new dialogue window for the DXF/DWG export is only opened after the file has loaded.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    62/67

    60 New Features of STRAKON Version 2011

    The new layout and modified text make the dialogue window easier to understand and use:

    Import color hatching previously: Import Color Areas

    Import bodies as color areas previously: Import Solids as Color Hatches

    The segment options and the settings have been expanded by the addition of the following points:

    Set WCS Coordinates Accord ing to Accumulation of Drawing Elements

    In many drawings the drawing elements are distributed over a wide area. Thus, for instance, the labelling of the coor-

    dinate origin point may be very far away from the building component elements of a plan view. When placing the file

    in the drawing, this results in a very large bounding box and it makes it difficult to define a conversion factor.

    If the options WCS in the segment origin and Set WCS coordinates according to accumulation of drawing

    elements are switched on, a small bounding box is created that only surrounds the building component elements of

    the plan view and omits the labeling of the coordinate origin which is far outside this box. No building component

    elements are left out. After completing the file import, all the elements, including those that were outside the bounding

    box, are displayed in the drawing.

    Import Splines

    For the import of AutoCAD Splines activate the check box.

    Only Import Visible Layers

    For the import of visible AutoCAD layers (i.e. layers that are active and thawed in AutoCAD), select the check box.

    Set Blocked Layer to Inactive

    Layers that are blocked in AutoCAD are set to inactive when imported.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    63/67

    STRAKON Part 7 Import/Export 61

    Import DXF/DWG as Template

    (not in STRAKONlight)

    The Import DXF/DWG as template function in the File > Import / Export menu allows you to import a template into

    the drawing with all the familiar options of the DXF/DWG import.

    After selecting the DXF/DWG file, only those settings that are relevant for the template import are offered as active inthe dialogue window:

    The template is placed in the drawing as previously described (see Template, page 26).

    Import Pixel Graphics

    Proportional Image Dimensions with Drag & Drop

    (not in STRAKONlight)

    After placing a pixel graphic in the drawing using Drag & Drop, as an option the image size can be scaled as required

    by defining the size proportionally using: Proportional.

    This ensures everything is displayed correctly, e.g. special text characters.

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    64/67

    62 New Features of STRAKON Version 2011

    Part 8 Data Export

    Data Export to Priamos

    The menu File > Interfaces > Priamos enables you to export your drawing data to the Priamos interface as a calcu-lation file.

    Specify the time point when the Priamos calculation file (*.dis) of the current drawing is to be created.

    In addition to the manual data export, it is also possible to export data automatically. The prerequisite for this is that

    the Calculation option in the Extras > Settings > Data export menu is switched on. A prompt regarding the data

    export is then given when the drawing is saved.

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    65/67

    STRAKON Part 9 Output 63

    Part 9 Output

    Print Reinforcement Schedules

    Cover SheetYou can now also output the cover sheet separately or with the steel schedule or mesh schedule.

    Parts List

    When this option is switched on, not only rebar items but also mesh items are now output in the parts list.

    Supporter Report

    As an option, the supporters can now be output only on the cover sheet orsimultaneously on both the cover sheetand the steel schedule or mesh schedule.

    Print Section

    The familiar function in the File > Print section menu has been given a new look and additional selection options are

    available.

    Selection menu of the printers/plotters set up on the computer

    Version 2011 DICAD Systeme GmbH

  • 7/28/2019 Extension Manual 2011

    66/67

    64 New Features of STRAKON Version 2011

    Device For calling up the printer settings (see STRAKON Help)

    Plot file For entering the file name and selecting the storage location

    DICAD Systeme GmbH Version 2011

  • 7/28/2019 Extension Manual 2011

    67/67

    STRAKON Appendix 65

    AppendixNew Icons for the Toolbar

    Center lines/Bisecting lines Identify intersection point

    Copy individually free Identify point on dimension line

    Breakdown Cube View Identify center of circle

    Update Cube View Identify help point

    CubeViewer Template

    Sheet dimensions as drawing (section) Steel Construction Design

    Current section as drawing (section) Steel Construction Variants

    Zoom in memory Export world coordinate list to Excel

    Publish Insert world coordinate list

    Drawing data

    Zoom out memory

    Multiple lines

    Move connection points

    Import DXF/DWG as template

    Identify text point

    Identify rebar point