16
USER MANUAL www.espuk.com EZTAG3 | PROXIMITY AND KEYPAD DOOR ENTRY EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 1

EZTAG3 | PROXIMITY AND KEYPAD DOOR ENTRY

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

U S E R M A N U A L

w w w . e s p u k . c o m

E Z T A G 3 | P R O X I M I T Y A N D K E Y P A D D O O R E N T R Y

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 1

2

System Components

Proximity and Keypad Reader 10 x Proximity Tags 1 x Hex Key 4 x Plastic wall plug

4 x Countersunk screws 1 x Diode and 1 x Capacitor

Optional Accessories

EVBPSBBLock Power Supply

EV-EXITPush to Release

EV-EBGEmergency Release

EV-ML-250/500XTElectro-magnetic Lock

ENTERDElectric Lock

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 2

3

Contents

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4EZTAG3 Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 EZTAG3 Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Advanced Programming GuideHow to set-up Access Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6How to set-up Access Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Deleting Access Pin or Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Changing Programming Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Clear all Pin and Tag Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Default to Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Lock 1 Output Operating Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Enable ‘Door Bell’ Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Enable ‘Tamper Alarm’ facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Access Pin Number for Lock 2 Output . . . . . . . . . . . . . . . . . . . . . . . . 10Deleting Access Pin for Lock 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Lock Output Operating Time for Lock 2 Output . . . . . . . . . . . . . . . . 11

System setup record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 3

4

Installation

Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart

(Side View)Push the keypad up to release from mount plate

Release hex screw from the bottom of the keypad

Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate,

re-fit the hex screw to secure into position.

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 4

5

EZTAG3 Wiring Example 1

43

+

+

+_

_

_

Red

NC

BlackGreenPurpleGreyPink

Electro-magnetic lock Electronic lock

Tag Reader

Indication LEDs

Keyp

ad

Tag Reader

Indication LEDs

Keyp

ad

EZTAG3 Wiring Example 2

Red

Black

Green/White

Purple/White

Yellow

White

Blue/White

Output forLock 2

(Volt-free)

N.O

COM

N.C

Speaker connectionfor ‘door bell’ facility

(8 0.5w recommended)

Input DC: +12V - +24V

Input AC: 12V - 24Vor

+_

Grey

Orange

Pink

Push button for Lock 1

(N.O) P.b for Lock 2

(N.O)

Green

Purple

Blue

Output forLock 1

(Volt-free)

N.O

COM

N.C

Lock -release time

N.C for Electro-magnetic lockN.O for Electronic lock

Capacitor for Electro-magnetic lock

Diode for Electronic Lock

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 5

6

ess Pin Number cc-up Aow to setHctionANumber

tepS

9

0 2

? ? ? ?

# #6

5

4

3

2

1

ogrammingo end prT

t be used)(1234 noter a 4 digit pinEn

0 0 0 9location number

ter a startingEn

ogrammingPrter En

(Default)1 2 3 4 1 2

Indicationypad eK

oneTToong L3 4

e

one TToong L

one TToong L

oneTToDouble9 9 9

ags ess TTaccA-up ow to setH

ctionANumbertepS

9

0 5

1

5

4

3

2

? ? ?

0 0 0 9location number*

ter a unusedEn

ed egistertags to be rter number ofEn

ogrammingPrter En

(Default)1 2 3 4 1

Indicationypad eK

one Tong L2 3 4

one Tong L

oneTTo

one Tong L9 9

# #

6

7 ogrammingpro endTTo

oneTTo

*Each tag will use up a location number

egister will auto rther batch tagsAll o

est serial number wlot the tag with theesenPr

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 6

7

ag ess Pin or TTaccDeleting ActionANumber

tepS

1

4

3

2 0 0 0 9pinnumber of tag/

ter the location En

ogrammingPrter En

(Default)1 2 3 4 1

teo deleTTo

# # ogrammingo end prTTo

Indicationypad eK

one Tong L

9 9

2 3 4

ogramming Pin Changing PrctionANumber

tepS

3

# #5

4

3

2

1 ogrammingPrter En

ogrammingo end prTTo

? ? ? ?ogramming pinpr

w 4 digitter neEn

? ? ? ? ogramming pinprw 4 diter nee-enR

(Default)1 2 3 4 1

Indicationypad eK

one TToong L2 3 4

one Tong Lgit

eed in twicterode is enogramming cprogramming mode, the 4 digit s prypad’eess kco acte; ToN

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 7

8

ag DataClear all Pin and TTactionANumber

tepS

8

8 8

# #

ogrammingPrter En

ogrammingo end prTo4

3

2

1(Default)

1 2 3 4 1 2

Indicationypad eK

oneTToong L2 3 4

one TToong L

actory SettingsDefault to FctionANumber

tepS

8

9 9

# #

ogrammingPrter En

ogrammingo end prTo4

3

2

1(Default)

1 2 3 4 1Indication

ypad eK

one TToong L2 3 4

oneTToong L

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 8

9

Lock 1 Output Operating Time ctionANumber

tepS

1

# #

onds 00-99of secter number En

ogrammingPrter En

ogrammingo end prTTo4

3

2

1

? ?

(Default)1 2 3 4 1 2

Indicationypad eK

oneTToong L2 3 4

one TToong L

acilityEnable ‘Door Bell’ FctionANumber

tepS

2

# #

ogrammingPrter En

ogrammingo end prTTo4

3

2

1

0 2 o enable To

door bell’ push in normal modeomes the ‘Bec

(Default)1 2 3 4 1 2

0 1 T

Indicationypad eK

one TToong L2 3 4

one TToong Lo disableTTo

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 9

10

’ facilityamper AlarmEnable ‘TctionANumber

tepS

6

# #

ogrammingPrter En

ogrammingo end prTTo4

3

2

1

0 2

xposed t sensor is edoor bell’ output if the ligh‘er and ternal buzzs inypad’eates the kamper alarm activT

o enableTo

(Default)1 2 3 4 1 2

0 1 oTTo

Indicationypad eK

oneTToong L2 3 4

e

one TToong Lo disable

or Lock 2 Outputess Pin Number fccActionANumber

tepS

9

0 3

? ? ? ?5

4

3

2

1

t be used)(1234 should noter a 4 digit pinEn

0 0location number

ter an unusedEn

ogrammingPrter En

(Default)1 2 3 4 1 2

0 9

t

Indicationypad eK

one TToong L3 4

oneTToong L

oneTToong L

one TToDouble9

# #6 ogrammingo end prT

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 10

11

or Lock 2 ess Pin fccDeleting ActionANumber

tepS

1 ogrammingPrter En

number of pinter the location En

4

3

2

(Default)1 2 3 4 1

teo deleTTo

# # ogrammingo end prTTo

0 0 0

4

5

Indicationypad eK

2 3 4oneTToong L

0 9

or LockLock Output Operating Time f

ctionANumbertepS

5

# #

onds 00-99of secter number En

ogrammingPrter En

ogrammingo end prTTo4

3

2

1

? ?

(Default)1 2 3 4 1 2

k 2 Output

Indicationypad eK

oneTToong L2 3 4

oneTToong L

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 11

12

To assist in future programming, it is recommended that arecord is made of the system setup.

System Location Tag Serial Tag Owner Notes Number (000-999) Number

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 12

13

System Location Tag Serial Tag Owner Notes Number (000-999) Number

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 13

14

ed tagegisterrt a esenPr

(B)

ess Pin numberccAogrammed ter a prEn(A)

ock 1elease Lo rTTo T ogramming mode ess prco acTTo

(Default)1 2 3 4 1 2 3 4

User Guide

Technical SpecificationDC input 12 - 24voltsAC input 12 - 24voltsStandby current 80maOperating current (without lock) 110ma

Working temperature -20c to +50c Reader frequency 125KHzIP rating 65Dimension 150 x 44 x 24mm

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 14

15

EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 15

w w w . e s p u k . c o m

Elite Security ProductsUnit 7, Target Park, Shawbank RdLakeside, Redditch B98 8YN

Telephone: 01527 51 51 50Fax: 01527 51 51 43

email: [email protected]

E&OE - Errors and omissions excepted. L15