ObjectiveProvide a simple, highly robust solution that possesses the following features:
• SevereAccident/StationBlackout(SBO)survivability
• Remoteelectronicoperation-upto1000feet
• Continuous,accuratereadingsgreaterthan1”resolution
• Simpleandflexibleinstallation–nopenetrationstoSFPliner orunderwatermodifications
• LowMaintenance–singlecable,nosensordriftovertime
• In-situfunctionaltests
• MeetsorexceedsUSNRCEA-12-051,JLD-ISG-2012-03,and NEI12-02requirements
• Optionaltemperaturesensorformonitoringandtrending
Features • ProprietaryTimeDomainReflectometry(TDR)technology
• Twochannelsof1EqualifiedNUMACelectronicswithqualified 1Esoftware
• NUMACelectronicscanbelocatedupto1000feetfromSFP
• Configurablealarms -3pre-setwaterlevelalarms -Suddenlossofcoolinginventoryalarm
-Optionalhightemperaturealarm
• Optionalcapabilitytointerfacewithplantcomputer
• Trendingdisplays–plotwaterleveland/ortemperature
• CommercialEthernet-basedwirelesscompatibility
• Reliablepowermanagement -40Wattsoperatingpower -25Wattsoperatingpowerindisplay“Sleep”mode -“OnDemand”operationforextendedbatteryoperation -72hourexternalbatterypower/UPScapability
• Passivesensor–nomovingpartsorelectronicsinSFParea
• Robuststainlesssteel,heavy-wallprobelargelyimperviousto temperature,radiation,saturationandcorrosionassociatedwith severeaccidentconditions
• Single,~0.5”diameterlow-losscoaxialcable–nocomplexwiring; simple,flexiblerouting
NUMAC QualificationSeismic(IEEEStd344),Environmental(IEEEStd323)5°Cto50°C,EMC (EPRITR-102323-R3).
AllNUMACelectronicassembliesmeetIPC-610requirements.
factsheet
GEHitachiNuclearEnergy
For more information, contact your GE Hitachi Nuclear Energy sales representative.
©2012GEHitachiNuclearEnergyAmericasLLC.AllRightsReserved.
SafetyEnhancementSpentFuelPoolLevelMonitor
The Spent Fuel Pool Level Monitor (SFPLM) is a robust liquid-level measurement system that provides accurate measurement of the Spent Fuel Pool (SFP) water level with NUMAC electronics located up to 1000’ from the SFP.
Our Commitment
Quality: GEHitachiNuclearEnergy(GEH)worksinaccordancewiththeUnitedStatesNRCacceptedGEHQualityAssuranceProgramDescriptionthatisineffectatthetimeworkisperformed,andinaccordancewiththeGEHISO-9001QualityManagementSystemDescription,asapprovedbyourISOregistrar
NUMAC SFPLM Chassis
•Narrow(nsec)PulseGeneration •ReflectedPulsedTMeasurement •DisplayWaterLevel1000ft.Low-LossCable
(inconduit)
ShortProbe CalibrationCable
GEHitachiNuclearEnergy
visit us at www.ge-energy.com/nuclear
©2012GEHitachiNuclearEnergyAmericasLLC.AllRightsReserved.
NUMAC InstrumentationTheNUMACSpentFuelPoolLevelMonitor(SFPLM)Systemconsistsoftwo(2)channelsof19”rack-mountedNUMACchassis,two(2)stainlesssteelpassiveprobes,andtwo(2)interfacecoaxialcables.
SFPLM Standard Features • ProprietaryTDRImpulsegeneratorandhighspeed discriminatorsforreflectedpulses–providescontinuouslevel measurement with high signal to noise ratio and high accuracy(<1inch).Electronicscanbelocatedinacontrolled environmentupto1000ftfromtheSFP.Nopost-installation sensorcalibrations.
• AutomaticbatterybackuponlossofACpowerprovidesupto 72hoursofoperation.Estimatedbatterycapacityremaining availableondisplay.
• LeveragestheNUMACSafety-RelatedOperatingSystem, includingwatchdogtimerstoguardagainstfaultyinputsand commonmodefailures.
• Built-inSelf-Testsystemmaximizeschannelavailabilityby detectingandannunciatingsystemfailuresin<1minute.
• DisplayscreensareNUREG0711HumanFactorsEngineered. Primaryinformationavailableonmaindisplaywithsoft-keys fortrenddisplays,diagnostics,surveillance,anduserhelp. Configurablealarmsandotherparametersarestoredinnon- volatilememorywithkey-lockandpasswordaccesscontrol.
• Digitalaccuracyforwaterlevel,lowdrift,and24month surveillanceintervals.Calibration/Surveillancefunctionsare controlledfromthefrontpanelwithoutdisconnectingcables orprobinginternalcircuits.
SFPLM Standard Features (continued) • Relayoutputs(Form-C)forwaterlevel,temperature,loss-of- inventoryalarmsareadjustable,plusanINOP/Trouble notificationalarmisincluded.
• Outputsforextendedmonitoringrange:
- Ethernetoutputprovidessystemparametersandvaluesforremote monitoringanddatastorage,andiscapableofinterfacingwithan 802.11wirelessrouter(transmit-onlyprotocol)
- Outputforlevelconfiguredfor0-10V,0-1V,or4-20mA
SFPLM Optional Enhancements • Optionalfuelpooltemperaturemeasurementwithdigital readoutsdisplayedonthefrontpanel,and0-10V,0-1V, or4-20mAoutput
• Optionalmulti-probecalibrationenablesinterchangeable electronicsforadditionalflexibility
• Optionalportableelectronicspackagingthatsatisfies“partial portability”guidanceasdescribedinNEI12-02,Revision1,Sect3.1
SFPLM Dimensions & Connections4U(EIAstandard)19”wideX7”highrack-mountchassisweighing32.5lbs.Chassis,retentionfasteners,andtopcoverareseismically-qualified.Connectorbracketinrearofchassisinterfacesallelectricalsignals.RetractorarmprovidescableroutingbehindNUMACchassisforfieldcabling.
SFPLM Power120VAC(90-132VAC),50-60Hertz,<40Watts,Eachchannelincludesaself-containedback-up24VDCsourcecapableofSFPLMoperationfor72hours.Thisutilizesa120VACpowersupplyanda24VDCpowersupplywhichareauctioned.The24VDCUPS(UninterruptiblePowerSupply)consistsofabattery,tricklecharger,andmonitoringcircuit.
Minimization of Obsolescence IssuesLeveragesindustry-standardNUMACdesign.1100+NUMACchassisinoperationwithover16,000yearsofoperationalexperience.GEHiscommittedtoprovidespareparts,trainingandeaseofmaintenancetominimizeobsolescenceconcerns.
TheSFPLMsharesmanycommoncomponentssuchaschassis,frontpanel,powersupplies,andelectronicmoduleswithotherNUMACfamilymemberstherebyfacilitatingsparesprovisioning.
NUMACobsolescenceismanagedatthecardlevel,minimizingtheimpactoftechnologychanges.Newcardsmanufacturedtodaymaintaincompatibilitywithexistinginstallations.ThisallowsGEHtocontinuesupportingtheNUMACChassisinstalledasfarbackas1985withoutrequiringasystemlevelchangeout.