Objective Provide a simple, highly robust solution that possesses the following features: Severe Accident/Station Blackout (SBO) survivability Remote electronic operation - up to 1000 feet Continuous, accurate readings greater than 1” resolution Simple and flexible installation – no penetrations to SFP liner or under water modifications Low Maintenance – single cable, no sensor drift over time In-situ functional tests Meets or exceeds US NRC EA-12-051, JLD-ISG-2012-03, and NEI 12-02 requirements Optional temperature sensor for monitoring and trending Features Proprietary Time Domain Reflectometry (TDR) technology Two channels of 1E qualified NUMAC electronics with qualified 1E software NUMAC electronics can be located up to 1000 feet from SFP Configurable alarms - 3 pre-set water level alarms - Sudden loss of cooling inventory alarm - Optional high temperature alarm Optional capability to interface with plant computer Trending displays – plot water level and/or temperature Commercial Ethernet-based wireless compatibility Reliable power management - 40 Watts operating power - 25 Watts operating power in display “Sleep” mode - “On Demand” operation for extended battery operation - 72 hour external battery power/UPS capability Passive sensor – no moving parts or electronics in SFP area Robust stainless steel, heavy-wall probe largely impervious to temperature, radiation, saturation and corrosion associated with severe accident conditions Single, ~0.5” diameter low-loss coaxial cable – no complex wiring; simple, flexible routing NUMAC Qualification Seismic (IEEE Std 344), Environmental (IEEE Std 323) 5°C to 50°C, EMC (EPRI TR-102323-R3). All NUMAC electronic assemblies meet IPC-610 requirements. fact sheet GE Hitachi Nuclear Energy For more information, contact your GE Hitachi Nuclear Energy sales representative. © 2012 GE Hitachi Nuclear Energy Americas LLC. All Rights Reserved. Safety Enhancement Spent Fuel Pool Level Monitor The Spent Fuel Pool Level Monitor (SFPLM) is a robust liquid-level measurement system that provides accurate measurement of the Spent Fuel Pool (SFP) water level with NUMAC electronics located up to 1000’ from the SFP. Our Commitment Quality: GE Hitachi Nuclear Energy (GEH) works in accordance with the United States NRC accepted GEH Quality Assurance Program Description that is in effect at the time work is performed, and in accordance with the GEH ISO-9001 Quality Management System Description, as approved by our ISO registrar NUMAC SFPLM Chassis • Narrow (nsec) Pulse Generation • Reflected Pulse dT Measurement • Display Water Level 1000ft. Low-Loss Cable (in conduit) Short Probe Calibration Cable

fact sheet - GE Hitachi Nuclear Energy · Objective Provide a simple, highly robust solution that possesses the following features: • Severe Accident/Station Blackout (SBO) survivability

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: fact sheet - GE Hitachi Nuclear Energy · Objective Provide a simple, highly robust solution that possesses the following features: • Severe Accident/Station Blackout (SBO) survivability

ObjectiveProvide a simple, highly robust solution that possesses the following features:

• SevereAccident/StationBlackout(SBO)survivability

• Remoteelectronicoperation-upto1000feet

• Continuous,accuratereadingsgreaterthan1”resolution

• Simpleandflexibleinstallation–nopenetrationstoSFPliner orunderwatermodifications

• LowMaintenance–singlecable,nosensordriftovertime

• In-situfunctionaltests

• MeetsorexceedsUSNRCEA-12-051,JLD-ISG-2012-03,and NEI12-02requirements

• Optionaltemperaturesensorformonitoringandtrending

Features • ProprietaryTimeDomainReflectometry(TDR)technology

• Twochannelsof1EqualifiedNUMACelectronicswithqualified 1Esoftware

• NUMACelectronicscanbelocatedupto1000feetfromSFP

• Configurablealarms -3pre-setwaterlevelalarms -Suddenlossofcoolinginventoryalarm

-Optionalhightemperaturealarm

• Optionalcapabilitytointerfacewithplantcomputer

• Trendingdisplays–plotwaterleveland/ortemperature

• CommercialEthernet-basedwirelesscompatibility

• Reliablepowermanagement -40Wattsoperatingpower -25Wattsoperatingpowerindisplay“Sleep”mode -“OnDemand”operationforextendedbatteryoperation -72hourexternalbatterypower/UPScapability

• Passivesensor–nomovingpartsorelectronicsinSFParea

• Robuststainlesssteel,heavy-wallprobelargelyimperviousto temperature,radiation,saturationandcorrosionassociatedwith severeaccidentconditions

• Single,~0.5”diameterlow-losscoaxialcable–nocomplexwiring; simple,flexiblerouting

NUMAC QualificationSeismic(IEEEStd344),Environmental(IEEEStd323)5°Cto50°C,EMC (EPRITR-102323-R3).

AllNUMACelectronicassembliesmeetIPC-610requirements.

factsheet

GEHitachiNuclearEnergy

For more information, contact your GE Hitachi Nuclear Energy sales representative.

©2012GEHitachiNuclearEnergyAmericasLLC.AllRightsReserved.

SafetyEnhancementSpentFuelPoolLevelMonitor

The Spent Fuel Pool Level Monitor (SFPLM) is a robust liquid-level measurement system that provides accurate measurement of the Spent Fuel Pool (SFP) water level with NUMAC electronics located up to 1000’ from the SFP.

Our Commitment

Quality: GEHitachiNuclearEnergy(GEH)worksinaccordancewiththeUnitedStatesNRCacceptedGEHQualityAssuranceProgramDescriptionthatisineffectatthetimeworkisperformed,andinaccordancewiththeGEHISO-9001QualityManagementSystemDescription,asapprovedbyourISOregistrar

NUMAC SFPLM Chassis

•Narrow(nsec)PulseGeneration •ReflectedPulsedTMeasurement •DisplayWaterLevel1000ft.Low-LossCable

(inconduit)

ShortProbe CalibrationCable

Page 2: fact sheet - GE Hitachi Nuclear Energy · Objective Provide a simple, highly robust solution that possesses the following features: • Severe Accident/Station Blackout (SBO) survivability

GEHitachiNuclearEnergy

visit us at www.ge-energy.com/nuclear

©2012GEHitachiNuclearEnergyAmericasLLC.AllRightsReserved.

NUMAC InstrumentationTheNUMACSpentFuelPoolLevelMonitor(SFPLM)Systemconsistsoftwo(2)channelsof19”rack-mountedNUMACchassis,two(2)stainlesssteelpassiveprobes,andtwo(2)interfacecoaxialcables.

SFPLM Standard Features • ProprietaryTDRImpulsegeneratorandhighspeed discriminatorsforreflectedpulses–providescontinuouslevel measurement with high signal to noise ratio and high accuracy(<1inch).Electronicscanbelocatedinacontrolled environmentupto1000ftfromtheSFP.Nopost-installation sensorcalibrations.

• AutomaticbatterybackuponlossofACpowerprovidesupto 72hoursofoperation.Estimatedbatterycapacityremaining availableondisplay.

• LeveragestheNUMACSafety-RelatedOperatingSystem, includingwatchdogtimerstoguardagainstfaultyinputsand commonmodefailures.

• Built-inSelf-Testsystemmaximizeschannelavailabilityby detectingandannunciatingsystemfailuresin<1minute.

• DisplayscreensareNUREG0711HumanFactorsEngineered. Primaryinformationavailableonmaindisplaywithsoft-keys fortrenddisplays,diagnostics,surveillance,anduserhelp. Configurablealarmsandotherparametersarestoredinnon- volatilememorywithkey-lockandpasswordaccesscontrol.

• Digitalaccuracyforwaterlevel,lowdrift,and24month surveillanceintervals.Calibration/Surveillancefunctionsare controlledfromthefrontpanelwithoutdisconnectingcables orprobinginternalcircuits.

SFPLM Standard Features (continued) • Relayoutputs(Form-C)forwaterlevel,temperature,loss-of- inventoryalarmsareadjustable,plusanINOP/Trouble notificationalarmisincluded.

• Outputsforextendedmonitoringrange:

- Ethernetoutputprovidessystemparametersandvaluesforremote monitoringanddatastorage,andiscapableofinterfacingwithan 802.11wirelessrouter(transmit-onlyprotocol)

- Outputforlevelconfiguredfor0-10V,0-1V,or4-20mA

SFPLM Optional Enhancements • Optionalfuelpooltemperaturemeasurementwithdigital readoutsdisplayedonthefrontpanel,and0-10V,0-1V, or4-20mAoutput

• Optionalmulti-probecalibrationenablesinterchangeable electronicsforadditionalflexibility

• Optionalportableelectronicspackagingthatsatisfies“partial portability”guidanceasdescribedinNEI12-02,Revision1,Sect3.1

SFPLM Dimensions & Connections4U(EIAstandard)19”wideX7”highrack-mountchassisweighing32.5lbs.Chassis,retentionfasteners,andtopcoverareseismically-qualified.Connectorbracketinrearofchassisinterfacesallelectricalsignals.RetractorarmprovidescableroutingbehindNUMACchassisforfieldcabling.

SFPLM Power120VAC(90-132VAC),50-60Hertz,<40Watts,Eachchannelincludesaself-containedback-up24VDCsourcecapableofSFPLMoperationfor72hours.Thisutilizesa120VACpowersupplyanda24VDCpowersupplywhichareauctioned.The24VDCUPS(UninterruptiblePowerSupply)consistsofabattery,tricklecharger,andmonitoringcircuit.

Minimization of Obsolescence IssuesLeveragesindustry-standardNUMACdesign.1100+NUMACchassisinoperationwithover16,000yearsofoperationalexperience.GEHiscommittedtoprovidespareparts,trainingandeaseofmaintenancetominimizeobsolescenceconcerns.

TheSFPLMsharesmanycommoncomponentssuchaschassis,frontpanel,powersupplies,andelectronicmoduleswithotherNUMACfamilymemberstherebyfacilitatingsparesprovisioning.

NUMACobsolescenceismanagedatthecardlevel,minimizingtheimpactoftechnologychanges.Newcardsmanufacturedtodaymaintaincompatibilitywithexistinginstallations.ThisallowsGEHtocontinuesupportingtheNUMACChassisinstalledasfarbackas1985withoutrequiringasystemlevelchangeout.