608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, WA 98312 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/12401 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

3925 NW Hope St, Bremerton, WA 98312 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/12401 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Inspection Report for Mr. Jordan JohnsonProperty Address: 3925 NW Hope St., Bremerton, Washington 98312

NW WASHINGTON HOME INSPECTIONS LLC

Carl Liberman License #1758Bainbridge Island, Washington

Page 3: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Table of Contents

Cover Page.................................................................1

Table of Contents ........................................................2

Intro Page ...................................................................3

Significant Issues ........................................................5

Repair & Maintenance Summary ................................7

Future Improvements................................................10

1 Roof .......................................................................12

2 Attic ........................................................................16

3 Exterior...................................................................17

4 Wall Exteriors.........................................................21

5 Structure ................................................................23

6 Electrical ................................................................29

7 Interior....................................................................34

8 Plumbing ................................................................37

9 Heating...................................................................41

10 Bathrooms............................................................45

11 Kitchen and Built-in Appliances............................48

12 Laundry Room .....................................................51

Invoice.......................................................................53

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 2 of 53

Page 4: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Date: 7/10/2018 Time: 01:00 PM Report ID: 180710 AProperty:3925 NW Hope St.Bremerton Washington 98312

Customer:Mr. Jordan Johnson

Real Estate Professional:Chris EllisFaira.com

Dear Mr. Johnson,

Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.

Three summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. Future improvements are provided for your consideration.

The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.

If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at [email protected]. I look forward to providing future home inspection needs to you, yourfriends, and family.

Warm Regards,

Carl Liberman

Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.

Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.

Future Improvements ( ) = Items or discoveries indicate that these systems or components should be considered forupgrade and/or modernization. Improved safety and/or energy efficiency may apply.

Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence ofpests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does notrespond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 3 of 53

Page 5: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

Standards of Practice:Washington State Standards of Practice forHome Inspectors & Inspections (WAC308-408C)

Type of building::Single Family (2-story)

Approximate Square Footage::1220

Approximate Year of OriginalConstruction::1941

Occupancy::Unoccupied, empty of furniture

Attending the Inspection::Vacant (inspector only)

Weather during the Inspection::Clear

Significant precipitation in last 3 days::No

Temperature during inspection::Over 65 (F) = 18 (C)

Ground/Soil surface condition:Dry

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 4 of 53

Page 6: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.

1. Roof

1.6 Asphalt Composition ShingleThis asphalt shingle roof may be near the end of it's life as indicated by generally loss of shingle dexterity, loss ofaggregate, significant moss build-up, and a sagging roof-line. The typical life expectancy of asphalt shingle roofs inthis climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofingcontractor for roof replacement options and costs.

3. Exterior

3.6 Deck, Balcony, Bridge and Porch,The elevated deck and steps on the west side of the home is in poor condition. The floor joists have beenweakened by rot and decay. Additional temporary support has been added. I do not recommend using this area ofdecking in it's current condition. I would recommend further evaluation, repairs/replacement by a licensed deckingcontractor.

5. Structure

5.1 Floor Structure(1) The bathroom floor has a noticeable slope in the floor. Temporary bracing has been constructed on the outsideof the structure as a means of additional support. The floor is supported by a main cross beam that is supported inan unconventional manner (post to wooden footer). I would recommend further assessment by a structural engineerand/or qualified contractor.(2) The front entry floor has a noticeable slope in the floor. The front door and closet door bind at the thresholds. Ahydraulic jack is providing support to the framing. I would recommend further assessment by a structural engineerand/or qualified contractor.

6. Electrical

6.21 Carbon Monoxide DetectorsCarbon monoxide alarms must be located outside of each separate sleeping area, in the immediate vicinity of thebedroom and on each level of the residence. Install in accordance with manufactures recommend guidance or hire alicensed contractor for proper installation.

Reference WAC 51-51-315: http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315

12. Laundry Room

12.2 Washer/DryerGas to dryer should be capped until connected to an appliance.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 5 of 53

Page 7: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Please note this section is not all-inclusive, please read the complete report.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 6 of 53

Page 8: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.

1. Roof

1.3 Roof Drainage System(1) This downspout elbow on the southeast corner of the home shows signs of leakage.

1.5 Chimney at Roof(1) I would recommend installing a masonry chimney cap to best shed water.

(2) The chimney cap for the living room wood stove is not properly installed.

3. Exterior

3.5 Porch(1) This planter box on the east side of the home is damaged and rotten. These conditions are conducive to wooddestroying organisms.(2) Debris below the deck on the west side of the home near the foundation. These conditions are conducive towood destroying organisms.

3.7 Exterior StairsBalusters are recommend for front steps not to exceed 4 inch spacing.

4. Wall Exteriors

4.2 Exterior Wall Penetrations(1) Gaps in the wood skirt around the bathroom may allow entry of rodents and pests.

(2) Gaps in the siding and missing trim around the exterior of the bathroom as a result of repairs/re-construction mayallow water penetration and subsequent damage. These conditions are conducive to wood destroying organisms.

5. Structure

5.0 Exterior Wall ConstructionI would recommend cutting back vegetation away from the foundation and wooden skirt of the home. Theseconditions are conducive to wood destroying organisms.

5.3 FoundationI noted this 1/8 inch wide crack in the block foundation wall on the west side. I would monitor and furtherrecommend consulting a foundations specialist and/or structural engineer if conditions are noted to change.

6. Electrical

6.19 Visible Branch Wiring

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 7 of 53

Page 9: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

This branch wiring on the outside of the west side of the home is not in an approved conduit. I would recommendcorrection by a licensed electrician.

6.20 Smoke Detectors1. Smoke detectors are recommended on each floor of the home, in each bedroom of the home, outside

common bedroom areas. Install in accordance with manufactures recommend guidance or hire a licensedcontractor for proper installation. Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040

2. The National Fire Protection Association (NFPA) recommend replacement of smoke detectors greater than10 years old.

7. Interior

7.8 StairsI would recommend as graspable hand-rail be installed in the basement stairwell.

8. Plumbing

8.2 Water Supply and DistributionCopper plumbing in the basement ceiling is poorly supported. I would recommend additional hangers be installed atapproximately 4 feet intervals by a qualified contractor.

8.4 Gas Water Heater(1)

1. Water heaters are required to be anchored or strapped to resist horizontal displacement due to earthquakemotion. Strappings shall be at points within the upper one-third and lower one-third of its verticaldimensions. At the lower point, a distance of not less than four (4) inches (102 mm) shall be maintainedfrom the controls to the strapping.

2. The pressure/temperature relief valve should be plumbed to the exterior of the home.3. Delivered hot water temperature was measured at the sink was 125 deg F. I would recommend adjusting

hot water temperature to deliver 120 deg F to reduce the risk of scalding.

I would recommend repairs by a licensed plumbing contractor.

8.5 Electric Water HeaterI believe this electric hot-water heater has been retired in-place. I would recommend removal. Seismic straps arerequired otherwise.

9. Heating

9.1 Furnace(1) The furnace cabinet is visibly dirty. I would recommend servicing by a licensed heating contractor and annuallythere-after.

9.5 Wood StoveThe living room wood-stove hearth surround is damaged and requires repair.

10. Bathrooms

10.10 Bathtub

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 8 of 53

Page 10: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

(1) The basement bathroom tub access panel has been removed.

(2) The upstairs bathroom shower actuator does not fully engage the shower.

10.14 SinkThe hot-water is not functional at the sink in the basement bathroom.

11. Kitchen and Built-in Appliances

11.2 CeilingsThe tile ceiling in the kitchen is sagging in places. An area has been removed previously. Budget for a ceilingreplacement/refurbishment.

11.10 RangePlease note, the exhaust to the conventional side of the oven is not connected to anything and terminate in thebasement stairwell.

12. Laundry Room

12.0 Receptacles, Switches, ConnectionsPlease note, dryer power has been disconnected.

12.3 Deep SinkThe deep sink has a crack in the left tub.

Please note this section is not all-inclusive, please read the complete report.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 9 of 53

Page 11: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

Future Improvements

1. Roof

1.2 Roof FlashingNo rake or drip edge flashing was installed at the time of the inspection. Lack of edge flashings may leave the edgesof roof sheathing and underlayment exposed to the deteriorating effects of weather, with damage from moisturesuch as delamination and decay possible. I would recommend further consulting a roofing contractor for options andcost to upgrade.

6. Electrical

6.15 Conventional Electrical Receptacles (interior)The homes outlets throughout are ungrounded. These outlets are marked to suggest they are protected by GFCI,however I was unable substantiate this. I would recommend upgrading this wiring and providing grounded outlets inaccordance with modern electrical safety standards in the future. Please further consult a licensed electricalcontractor for options and costs.

6.16 GFCI/AFCI Electrical ReceptaclesLimited fault circuit interrupter (GFCI) protection of home electrical receptacles was provided in the home at the timeof inspection. Although GFCI protection may not have been required at the time the home was built, I recommendthat electrical receptacles located in basements, crawlspaces, garages, the home exterior, and interior receptacleslocated within 6 feet of a plumbing fixture be provided with ground fault circuit interrupter (GFCI) protection forimproved electrical safety.

7. Interior

7.2 CeilingsPlease note, the basement living room and stair-well has a low ceiling and obstructions as low as 6 feet.

8. Plumbing

8.4 Gas Water Heater(2) Please note, this water heater may have exceeded it's typical life-span of 12 to 18 years. Consider a homewarranty to mitigate repair/replacement costs. Budget for a replacement in the future.

9. Heating

9.0 Presence of installed heat source in each roomPlease note, the sole heating source for the upstairs is a single heating register at the top of the stairs in the hallway.

9.1 Furnace(2) Typical expected life-span of a gas-fired medium efficiency furnace is 16 - 20 years. Please budget accordingly.Service annually.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 10 of 53

Page 12: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

11. Kitchen and Built-in Appliances

11.9 Kitchen AppliancesPlease note, kitchen appliances are generally older models. Consider purchasing a home warranty that covers suchappliances.

11.11 Range HoodNo range hood or exhaust system was installed at the time of the inspection. I would recommend that an exhausthood or air filtration system be installed to prevent possible moisture damage and grease accumulation on walls andceiling adjacent to the range. All work should be performed by a qualified contractor.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 11 of 53

Page 13: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.

Styles & Materials

Method of inspection:Walked the roof

The roof style was:Gable

Primary roof-covering type:3-tab Fiberglass Asphalt Shingle

Drainage system description:Gutters and downspouts installed

Chimney flue material:Unlined CMU

Underlayment/Interlayment::Not Visible

Sky Light(s):None

Items

1.0 Roof Structure ExteriorComments: Limitation

1.1 UnderlaymentComments: Not Inspected

1.2 Roof FlashingComments: Inspected

1.3 Roof Drainage SystemComments: Inspected

Generally not visible, limited attic area.

No rake or drip edge flashing wasinstalled at the time of the inspection.Lack of edge flashings may leave theedges of roof sheathing andunderlayment exposed to thedeteriorating effects of weather, withdamage from moisture such asdelamination and decay possible. Iwould recommend further consulting aroofing contractor for options and costto upgrade.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 12 of 53

Page 14: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

1.4 Plumbing and Combustion VentsComments: Inspected

1.5 Chimney at RoofComments: Inspected

(1) This downspout elbow on thesoutheast corner of the home showssigns of leakage.

(2) Unconventional gutter anddownspout arrangement.

(1) I would recommend installinga masonry chimney cap to best shedwater.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 13 of 53

Page 15: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

1.6 Asphalt Composition ShingleComments: Inspected

(2) The chimney cap for theliving room wood stove is not properlyinstalled.

This asphalt shingle roof may be near the end of it's life as indicated by generally loss of shingledexterity, loss of aggregate, significant moss build-up, and a sagging roof-line. The typical life expectancy ofasphalt shingle roofs in this climate is approximately 20 years, please budget accordingly. Please furtherconsult a licensed roofing contractor for roof replacement options and costs.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 14 of 53

Page 16: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 15 of 53

Page 17: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).

Styles & Materials

Attic info:Attic hatch

Attic inspected from:Inside the attic

Attic thermal insulation material:Fiberglass Batt

Approximate attic thermal insulationdepth:

Less than 6 inches

Roof Structure Ventilation:Attic ventilation appeared sufficient

Roof structure ventilation device type:Roof vents

Roof Framing Type:Conventional Framing

Roof Sheathing Material:Wood boards

Items

2.0 Attic AccessComments: Inspected

2.1 Roof Framing (from attic)Comments: Inspected

2.2 Roof SheathingComments: Inspected

2.3 Roof Structure VentilationComments: Inspected

2.4 Attic ElectricalComments: Inspected

2.5 Venting Systems (Kitchens, Baths and Laundry)Comments: Inspected

2.6 Attic Rodent ActivityComments: Inspected

The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 16 of 53

Page 18: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.

The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.

Styles & Materials

Driveway Material:Gravel

Walkway Materials:Gravel

Appurtenance:Covered porch

Downspout Discharge:Above Grade

Lot Description:Moderate Slope

Clearance to Grade:Non-Standard

Items

3.0 Exterior ViewsComments: Inspected

3.1 DrivewayComments: Inspected

3.2 WalkwaysComments: Inspected

3.3 General GroundsComments: Inspected

3.4 Exterior TrimComments: Inspected

3.5 PorchComments: Inspected

(1) This planter box on the eastside of the home is damaged androtten. These conditions areconducive to wood destroyingorganisms.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 17 of 53

Page 19: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

3.6 Deck, Balcony, Bridge and Porch,Comments: Inspected

(2) Debris below the deck on thewest side of the home near thefoundation. These conditions areconducive to wood destroyingorganisms.

The elevated deck and steps on the west side of the home is in poor condition. The floor joists havebeen weakened by rot and decay. Additional temporary support has been added. I do not recommend usingthis area of decking in it's current condition. I would recommend further evaluation, repairs/replacement by alicensed decking contractor.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 18 of 53

Page 20: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

3.7 Exterior StairsComments: Inspected

3.8 Additional StructuresComments: Not Inspected

Balusters are recommend for front steps not to exceed 4 inch spacing.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 19 of 53

Page 21: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

Detached garage - not inspected.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 20 of 53

Page 22: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.

The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.

Styles & Materials

Exterior wall-covering Material:Vertical Wood SidingCedar shingle

Exterior Doors:Solid wood

Items

4.0 Door ExteriorsComments: Inspected

4.1 Window ExteriorsComments: Inspected

4.2 Exterior Wall PenetrationsComments: Inspected

(1) Gaps in the wood skirtaround the bathroom may allow entryof rodents and pests.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 21 of 53

Page 23: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

4.3 Exterior Wall MembraneComments: Inspected

The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

(2) Gaps in the siding andmissing trim around the exterior of thebathroom as a result of repairs/re-construction may allow waterpenetration and subsequent damage.These conditions are conducive towood destroying organisms.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 22 of 53

Page 24: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.

Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.

Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.

Styles & Materials

Typical Ceiling Structure:Drywall attached to dimensional lumber

ceiling joists

Exterior Wall Structures:Wood Frame

Wall Insulation:Not Visible

Foundation Configuration:Partially-finished basementBasement walkoutCrawlspace

Foundation Method/Materials:Concrete Masonry Unit (CMU) foundation

wallsPost and Pier

Main Floor Structure:2x8 wood joistsWood Boards

Main Floor Structure- Perimeter Bearing:Rests on top of foundation wall

Main Floor Structure- IntermediateSupport:

Wood beam girderWood-framed wallsWood posts

Floor System Insulation:NONE

Evidence of Seismic Protection:None Noted

Crawl Space Vapor Barrier:Plastic

Items

5.0 Exterior Wall ConstructionComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 23 of 53

Page 25: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

5.1 Floor StructureComments: Inspected

I would recommend cutting back vegetation away from the foundation and wooden skirt of the home.These conditions are conducive to wood destroying organisms.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 24 of 53

Page 26: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

(1) The bathroom floor has a noticeable slope in the floor. Temporary bracing has been constructed onthe outside of the structure as a means of additional support. The floor is supported by a main cross beamthat is supported in an unconventional manner (post to wooden footer). I would recommend furtherassessment by a structural engineer and/or qualified contractor.

temporary bracing

foundation wall

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 25 of 53

Page 27: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 26 of 53

Page 28: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

5.2 Insulation Under Floor SystemComments: Inspected

(2) The front entry floor has a noticeable slope in the floor. The front door and closet door bind at thethresholds. A hydraulic jack is providing support to the framing. I would recommend further assessment by astructural engineer and/or qualified contractor.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 27 of 53

Page 29: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

5.3 FoundationComments: Inspected

5.4 Crawl Space Rodent ActivityComments: Inspected

The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

I noted this 1/8 inch wide crack inthe block foundation wall on the westside. I would monitor and furtherrecommend consulting a foundationsspecialist and/or structural engineer ifconditions are noted to change.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 28 of 53

Page 30: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.

The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting

Styles & Materials

Electrical Service Conductors:Overhead serviceAluminum120/240 volt service

Service Panel Ampacity:200 amps

Service Panel Type:Load Center

Service Panel Manufacturer:Cuttler Hammer

Service Disconnect Location:At Service Panel

Service Disconnect Type:Breaker

Service Grounding Electrode:Not Visible

Wiring Methods:Romex

Type of Branch Wiring:Solid CopperStranded Copper

Ground Fault Circuit Interruptor (GFCI)Protection:

YES

Arc Fault Circuit Interruptor (AFCI)Protection:

NO

Items

6.0 General Electrical System DescriptionComments: Inspected

6.1 General Electrical System ConditionComments: Inspected

6.2 Service Drop, Drip Loop, Splice and AttachmentComments: Inspected

6.3 Mast & WeatherheadComments: Inspected

6.4 Electric MeterComments: Inspected

6.5 Service Entrance ConductorsComments: Inspected

6.6 Service Panel ManufacturerComments: Inspected

6.7 Service Panel Exposure RatingComments: Inspected

6.8 Service Panel Cabinet, Ampacity, and CoverComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 29 of 53

Page 31: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

6.9 Service Panel WiringComments: Inspected

6.10 Service DisconnectComments: Inspected

6.11 Overcurrent Protection DevicesComments: Inspected

6.12 Service Grounding Electrode System & Service BondComments: Inspected

6.13 Equipment Grounding & BondingComments: Inspected

6.14 Exterior Electrical ReceptaclesComments: Inspected

6.15 Conventional Electrical Receptacles (interior)Comments: Inspected

The homes outlets throughout are ungrounded. These outlets are marked to suggest they are protectedby GFCI, however I was unable substantiate this. I would recommend upgrading this wiring and providinggrounded outlets in accordance with modern electrical safety standards in the future. Please further consult alicensed electrical contractor for options and costs.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 30 of 53

Page 32: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

6.16 GFCI/AFCI Electrical ReceptaclesComments: Inspected

6.17 SwitchesComments: Inspected

6.18 LightingComments: Inspected

6.19 Visible Branch WiringComments: Inspected

Limited fault circuit interrupter(GFCI) protection of home electricalreceptacles was provided in the homeat the time of inspection. AlthoughGFCI protection may not have beenrequired at the time the home wasbuilt, I recommend that electricalreceptacles located in basements,crawlspaces, garages, the homeexterior, and interior receptacleslocated within 6 feet of a plumbingfixture be provided with ground faultcircuit interrupter (GFCI) protection forimproved electrical safety.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 31 of 53

Page 33: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

6.20 Smoke DetectorsComments: Inspected

6.21 Carbon Monoxide DetectorsComments: Inspected

This branch wiring on the outsideof the west side of the home is not inan approved conduit. I wouldrecommend correction by a licensedelectrician.

1. Smoke detectors arerecommended on each floorof the home, in eachbedroom of the home,outside common bedroomareas. Install in accordancewith manufacturesrecommend guidance or hirea licensed contractor forproper installation. ReferenceWAC 212-10-040:http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040

2. The National Fire ProtectionAssociation (NFPA)recommend replacement ofsmoke detectors greater than10 years old.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 32 of 53

Page 34: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

6.22 DoorbellComments: Inspected

The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

Carbon monoxide alarms mustbe located outside of each separatesleeping area, in the immediatevicinity of the bedroom and on eachlevel of the residence. Install inaccordance with manufacturesrecommend guidance or hire alicensed contractor for properinstallation.

Reference WAC 51-51-315:http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 33 of 53

Page 35: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

7. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.

Styles & Materials

Walls and Ceilings:DrywallGypsum Board

Floor Covering Materials:CarpetSheet VinylHardwood

Interior Doors:Solid Wood

Window Material:VinylWoodAluminum

Window Glazing:Single-paneDouble-pane

Window Operation:Single-hungSliding

Smoke/CO Detectors:Smoke detectors installedCarbon Monoxide detectors were not

installedAdditional smoke detectors

recommendedAdditional carbon monoxide detector(s)

required

Items

7.0 FloorsComments: Inspected

7.1 WallsComments: Inspected

7.2 CeilingsComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 34 of 53

Page 36: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

7.3 LightingComments: Inspected

7.4 DoorsComments: Inspected

7.5 Windows and SkylightsComments: Inspected

7.6 Interior TrimComments: Inspected

7.7 Cabinets and CountertopsComments: Inspected

7.8 StairsComments: Inspected

Please note, the basement living room and stair-well has a low ceiling and obstructions as low as 6 feet.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 35 of 53

Page 37: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

I would recommend as graspable hand-rail be installed in the basement stairwell.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 36 of 53

Page 38: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

8. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).

Styles & Materials

Water Supply Source:Public Water Supply

Main Water Supply Pipe:Not Visible

Main Water Supply Location:Not Located

Water Distribution Pipes:1/2-inch and 3/4-inch copper

Distribution Pipe Bonding:Not Visible

Sewage System Type:Public

Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)Cast Iron

Water Heater Manufacturer:A O Smith

Date of Manufacture:Unable to determine

Water Heater Fuel Type:Gas

Water Heater Type:Tank (conventional)

Water Heater Tank Capacity:40 gallons

Water Heater Location:Basement

Washer Drain Size:Not located

Gas Pipe Material:Black Steel

Type of Gas:Natural Gas

Items

8.0 Exterior PlumbingComments: Inspected

8.1 Source of WaterComments: Inspected

8.2 Water Supply and DistributionComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 37 of 53

Page 39: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

8.3 Sewage and DWV SystemsComments: Inspected

8.4 Gas Water HeaterComments: Inspected

Copper plumbing in the basement ceiling is poorly supported. I would recommend additional hangers beinstalled at approximately 4 feet intervals by a qualified contractor.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 38 of 53

Page 40: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

8.5 Electric Water HeaterComments: Not Inspected

(1)1. Water heaters are required to be anchored or strapped to resist horizontal displacement due to

earthquake motion. Strappings shall be at points within the upper one-third and lower one-third of itsvertical dimensions. At the lower point, a distance of not less than four (4) inches (102 mm) shall bemaintained from the controls to the strapping.

2. The pressure/temperature relief valve should be plumbed to the exterior of the home.3. Delivered hot water temperature was measured at the sink was 125 deg F. I would recommend

adjusting hot water temperature to deliver 120 deg F to reduce the risk of scalding.

I would recommend repairs by a licensed plumbing contractor.

(2) Please note, this water heatermay have exceeded it's typical life-span of 12 to 18 years. Consider ahome warranty to mitigate repair/replacement costs. Budget for areplacement in the future.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 39 of 53

Page 41: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.

I believe this electric hot-waterheater has been retired in-place. Iwould recommend removal. Seismicstraps are required otherwise.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 40 of 53

Page 42: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

9. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).

Styles & Materials

Heating System Type:Gas-fired Furnace (medium efficiency)

Energy Source:Natural gas

Number of Heat Systems (excludingwood):

One

Heating/Cooling Ducts:Partially insulated

Air Filter:Disposable

Air Filter Location:Behind return air registers

Heating System Brand:Unable to determine (missing/illegible

information)

Types of FIreplaces:None

Number of Woodstoves:One

Items

9.0 Presence of installed heat source in each roomComments: Inspected

Please note, the sole heating source for the upstairs is a single heating register at the top of the stairs inthe hallway.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 41 of 53

Page 43: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

9.1 FurnaceComments: Inspected

(1) The furnace cabinet is visibly dirty. I would recommend servicing by a licensed heating contractor andannually there-after.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 42 of 53

Page 44: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

9.2 Fuel, Piping and SupportComments: Inspected

9.3 ThermostatComments: Inspected

9.4 Filter conditionComments: Inspected

9.5 Wood StoveComments: Inspected

(2) Typical expected life-span ofa gas-fired medium efficiency furnaceis 16 - 20 years. Please budgetaccordingly. Service annually.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 43 of 53

Page 45: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

The living room wood-stovehearth surround is damaged andrequires repair.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 44 of 53

Page 46: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

10. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation

Styles & Materials

Exhaust Fans:Fan only

Items

10.0 FloorsComments: Inspected

10.1 WallsComments: Inspected

10.2 CeilingsComments: Inspected

10.3 DoorsComments: Inspected

10.4 WindowsComments: Inspected

10.5 Electrical Receptacles and SwitchesComments: Inspected

10.6 LightingComments: Inspected

10.7 VentilationComments: Inspected

10.8 CabinetsComments: Inspected

10.9 ToiletComments: Inspected

10.10 BathtubComments: Inspected

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 45 of 53

Page 47: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

10.11 ShowerComments: Inspected

10.12 Medicine CabinetComments: Inspected

10.13 MirrorsComments: Inspected

10.14 SinkComments: Inspected

(1) The basement bathroom tubaccess panel has been removed.

(2) The upstairs bathroomshower actuator does not fully engagethe shower.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 46 of 53

Page 48: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.

The hot-water is not functional atthe sink in the basement bathroom.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 47 of 53

Page 49: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

11. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.

Styles & Materials

Cabinets:Solid Wood

Countertop Material:Laminate

Range:Gas/electric combination

Range/Oven Brand:Monarch

Range Hood:No hood installed

Items

11.0 FloorsComments: Inspected

11.1 WallsComments: Inspected

11.2 CeilingsComments: Inspected

The tile ceiling in the kitchen is sagging in places. An area has been removed previously. Budget for aceiling replacement/refurbishment.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 48 of 53

Page 50: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

11.3 DoorsComments: Inspected

11.4 WindowsComments: Inspected

11.5 Interior TrimComments: Inspected

11.6 Receptacles and SwitchesComments: Inspected

11.7 LightingComments: Inspected

11.8 CabinetsComments: Inspected

11.9 Kitchen AppliancesComments: Inspected

11.10 RangeComments: Inspected

Please note, kitchen appliancesare generally older models. Considerpurchasing a home warranty thatcovers such appliances.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 49 of 53

Page 51: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

11.11 Range HoodComments: Not Inspected

11.12 CounterComments: Inspected

11.13 SinkComments: Inspected

The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.

Please note, the exhaust to the conventional side of the oven is not connected to anything and terminatein the basement stairwell.

No range hood or exhaust system was installed at the time of the inspection. I would recommend that anexhaust hood or air filtration system be installed to prevent possible moisture damage and greaseaccumulation on walls and ceiling adjacent to the range. All work should be performed by a qualifiedcontractor.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 50 of 53

Page 52: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

12. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.

Styles & Materials

Dryer Power:Gas

Dryer Vent:Not Visible

Dryer 240-volt electrical receptacle:None

Dryer Gas Supply:Natural gas

Items

12.0 Receptacles, Switches, ConnectionsComments: Inspected

12.1 Dryer VentingComments: Not Inspected

12.2 Washer/DryerComments: Inspected

Please note, dryer power hasbeen disconnected.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 51 of 53

Page 53: FAIRA TRANSPARENCY REPORTS 3925 NW Hope St, Bremerton, … · this climate is approximately 20 years, please budget accordingly. Please further consult a licensed roofing contractor

12.3 Deep SinkComments: Inspected

The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.

Gas to dryer should be cappeduntil connected to an appliance.

The deep sink has a crack in the left tub.

NW WASHINGTON HOME INSPECTIONS LLC Johnson

3925 NW Hope St. Page 52 of 53