FAIRA TRANSPARENCY REPORTS
504 Cantershire Pl NE, Bremerton, WA 98311
Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.
You may view more detailed information for this home and can make an offer at
http://www.faira.com/listings/12160 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
Inspection Report for Ms. Lidia FarrowProperty Address: 504 Cantershire Pl BE, Bremerton, Washington 98311
NW WASHINGTON HOME INSPECTIONS LLC
Carl Liberman License #1758Bainbridge Island, Washington
Table of Contents
Cover Page.................................................................1
Table of Contents ........................................................2
Intro Page ...................................................................3
Significant Issues ........................................................5
Repair & Maintenance Summary ................................6
Future Improvements..................................................9
1 Roof ....................................................................... 11
2 Attic ........................................................................14
3 Exterior...................................................................16
4 Wall Exteriors.........................................................22
5 Structure ................................................................24
6 Electrical ................................................................28
7 Garage...................................................................33
8 Interior....................................................................36
9 Plumbing ................................................................40
10 Heating.................................................................44
11 Bathrooms............................................................48
12 Kitchen and Built-in Appliances ...........................51
13 Laundry Room .....................................................54
Invoice.......................................................................56
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 2 of 56
Date: 6/6/2018 Time: 11:00 AM Report ID: 180606 AProperty:504 Cantershire Pl BEBremerton Washington 98311
Customer:Ms. Lidia Farrow
Real Estate Professional:Chris EllisFaira.com
Dear Ms. Farrow,
Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.
Three summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. Future improvements are provided for your consideration.
The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.
If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at [email protected]. I look forward to providing future home inspection needs to you, yourfriends, and family.
Warm Regards,
Carl Liberman
Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.
Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
Future Improvements ( ) = Items or discoveries indicate that these systems or components should be considered forupgrade and/or modernization. Improved safety and/or energy efficiency may apply.
Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence ofpests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does notrespond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 3 of 56
effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Standards of Practice:Washington State Standards of Practice forHome Inspectors & Inspections (WAC308-408C)
Type of building::Single Family - Split Level
Approximate Square Footage::1834
Approximate Year of OriginalConstruction::1975
Occupancy::Unoccupied, empty of furniture
Attending the Inspection::Owner
Weather during the Inspection::Clear
Significant precipitation in last 3 days::No
Temperature during inspection::Below 60 (F) = 15.5 (C)
Ground/Soil surface condition:Dry
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 4 of 56
Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.
5. Structure
5.4 Crawlspace(1) Considerable amounts of fras from an unidentified wood destroying insect are present in the crawlspace alongthe foundation wall and framing below the living room adjacent to the front door. I did not notice any active insectactivity and did not note any visible structural damage. Further damage to the wooden structure, if any, may existand be concealed.
I would recommend further inspection and treatment as required by a licensed pest control operator.
(2) Approximately one half of the floor insulation has fallen from the floor above. The moisture barrier is made of anolder and thinner plastic than currently recommended.
I would recommend a general clean-up, insulation and moisture barrier replacement by a crawlspace remediationcontractor.
6. Electrical
6.8 Service Panel WiringSeveral circuit breakers in the main electrical panel are providing power to more than one branch circuit. I wouldrecommend correction by a licensed electrician.
6.15 GFCI/AFCI Electrical ReceptaclesNo ground fault circuit interrupter (GFCI) protection of homes kitchen, garage or exterior electrical receptacles wasprovided in the home at the time of inspection. Although GFCI protection may not have been required at the time thehome was built, I recommend that electrical receptacles located in basements, crawlspaces, garages, the homeexterior, and interior receptacles located within 6 feet of a plumbing fixture be provided with ground fault circuitinterrupter (GFCI) protection for improved electrical safety.
6.20 Carbon Monoxide DetectorsNo carbon monoxide detectors were installed. Carbon monoxide alarms must be located outside of each separatesleeping area, in the immediate vicinity of the bedroom and on each level of the residence. Install in accordance withmanufactures recommend guidance or hire a licensed contractor for proper installation.
Reference WAC 51-51-315: http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 5 of 56
Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
1. Roof
1.0 Roof Structure ExteriorThe soffit on the east side has some slight water damage to the 1 X 4 soffit board. These conditions are conduciveto wood destroying organisms.
1.2 Roof FlashingNo kick-out flashing was installed where walls extended past roof edges. Kick-out flashing is designed and installedto divert water from behind the exterior wall covering at areas of the home where a sidewall extends out past aconnecting roof eve. Please further consult with a qualified roofing contractor to discuss options and costs foradding kick-out flashing.
1.3 Roof Drainage SystemThis downspout on the southeast corner of the home discharges back towards the foundation. I would recommendadjusting the downspout and adding an extension so that it discharges down-grade and drains away from thefoundation.
2. Attic
2.0 Attic AccessI would recommend insulating the attic access panel for improved energy efficiency.
3. Exterior
3.1 Driveway(2) I noted some root damage to the asphalt driveway near the garage door and walk-way.
3.3 General Grounds(1) This tree is very close to the foundation. Some heaving of the concrete sidewalk is noted.
3.4 Exterior Trim(1) Some minor rot is noted in the trim adjacent to the front door. I would recommend removal and replacement ofaffected components. These conditions are further conducive to wood destroying organisms.(2) I noted some ant activity and damage to the trim in this area on the right hand side of the garage. I wouldrecommend further assessment and treatment by a licensed pest control operator and repairs to the trim by aqualified contractor. These conditions are further conducive to wood destroying organisms.
3.6 Deck, Balcony, Bridge and Porch,(1) Please note, I was unable to inspect the ledger detail or deck framing as it is not accessible.
I would recommend a coat of stain and/or preservative in order to maximize the remaining life-span of this outdoordeck.
(2) I would recommend extending the guard-rail as this area of the deck has an exposure greater than 24 inches.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 6 of 56
(3) This step is constructed in a temporary fashion. I would recommend a more permanent installation by a licenseddecking contractor.
3.8 Additional StructuresShed - not inspected.
4. Wall Exteriors
4.5 Wood Siding(1) Rot has developed in this section of siding due to past downspout leak. I would recommend verifying thedownspout is no longer leaking and replace this section of siding. These conditions are further conducive to wooddestroying organisms.(2) I would recommend cleaning and repainting this section of siding where some ivy was removed on the back ofthe home.
7. Garage
7.0 Vehicle Doors(1)
1. The garage vehicle door failed to reverse when a reasonable amount of resistance was applied. TheInspector recommends service by a qualified garage door contractor.
2. No photoelectric sensors were installed. Photoelectric sensors are devices installed to prevent injury byraising the vehicle door if the sensor detects a person in a position in which they may be injured by thedescending door. Installation of photo sensors in new homes has been required by generally-acceptedsafety standards since 1993. I woad recommend correction by a licensed garage door contractor.
(2)1. Both vehicle doors have some delamination of the lower-most wood panel.2. I would recommend replacing the rubber threshold on both garage doors.
8. Interior
8.5 Doors(1) This door's handle is loose.
(2) The bedroom door does not latch.
(3) I would recommend installing floor mounted door guides to the kitchen pantry sliding doors.
8.6 Windows and SkylightsThe master-bedroom windows are mounted very close to the floor and may pose a fall hazard if the windows areopen.
9. Plumbing
9.4 Electric Water Heater(2) Delivered hot water temperature measured at the kitchen sink was tepid at 104 deg F. I would recommendservicing and adjustment by a qualified contractor
10. Heating
10.1 Furnace
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 7 of 56
(1) The furnace cabinet is visibly dirty with soot and combustion debris. I would recommend servicing by a licensedheating contractor and annually thereafter.
10.5 FireplaceThe fireplace glass is visibly dirty and the flame more diffuse than I am typically used to seeing. I would recommendservicing by a qualified contractor.
11. Bathrooms
11.10 Shower(1) The shower surround in the hall bathroom requires cleaning and caulk replacement. Some buckling of the tile isnoted at the foot of the tub.(2) The showerhead in the hall bathroom requires replacement.
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 8 of 56
Future Improvements
1. Roof
1.5 Asphalt Composition ShingleThe typical life expectancy of asphalt shingle roofs in this climate is approximately 20 years, please budgetaccordingly.
3. Exterior
3.1 Driveway(1) The driveway drains towards the garage. Please keep the drain-path clear for to ensure water does not flowtowards the garage doors.
3.3 General Grounds(2) Large trees overhead will required periodic cleaning of the roof of debris, needles, and leaves.
5. Structure
5.2 Insulation Under Floor SystemNo insulation exists in the laundry room ceiling, which is an unconditioned space. Additionally, the great room hasno insulation above the drop ceiling. Consider insulating if these spaces are primarily kept unconditioned.
6. Electrical
6.7 Service Panel Cabinet, Ampacity, and CoverThis older style split panel electrical panel does not have a single isolation breaker. Consider replacing this panelwith a modern electrical panel in the future.
6.19 Smoke DetectorsSmoke detectors are recommended on each floor of the home, in each bedroom of the home, outside commonbedroom areas. Install in accordance with manufactures recommend guidance or hire a licensed contractor forproper installation.
Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040
9. Plumbing
9.1 Source of WaterPlease note, the main water cut-off valve is located in the crawlspace below the living room.
9.4 Electric Water Heater(1) Please note, this older model water heater may have exceeded the typical life-span of 12 - 18 years. Consider ahome warranty to mitigate repair/replacement costs. Budget for a replacement and the additional installation of asurge tank in the future.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 9 of 56
10. Heating
10.1 Furnace(2) This older model furnace (1975) has exceed it's typical life expectancy of 16 - 20 years. I would recommend youbudget for a replacement unit.
12. Kitchen and Built-in Appliances
12.10 Kitchen AppliancesConsider purchasing a home warranty that covers your kitchen and other appliances to mitigate any near-termrepair or replacement costs considering their age.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 10 of 56
1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.
Styles & Materials
Method of inspection:Walked the roof
The roof style was:Gable
Primary roof-covering type:3-tab Fiberglass Asphalt Shingle
Drainage system description:Gutters and downspouts installed
Chimney flue material:Tile
Underlayment/Interlayment::Not Visible
Sky Light(s):TwoSolar tube
Items
1.0 Roof Structure ExteriorComments: Inspected
1.1 UnderlaymentComments: Not Inspected
1.2 Roof FlashingComments: Inspected
The soffit on the east side hassome slight water damage to the 1 X 4soffit board. These conditions areconducive to wood destroyingorganisms.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 11 of 56
1.3 Roof Drainage SystemComments: Inspected
No kick-out flashing was installed where walls extended past roof edges. Kick-out flashing is designedand installed to divert water from behind the exterior wall covering at areas of the home where a sidewallextends out past a connecting roof eve. Please further consult with a qualified roofing contractor to discussoptions and costs for adding kick-out flashing.
This downspout on the southeastcorner of the home discharges backtowards the foundation. I wouldrecommend adjusting the downspoutand adding an extension so that itdischarges down-grade and drainsaway from the foundation.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 12 of 56
1.4 Plumbing and Combustion VentsComments: Inspected
1.5 Asphalt Composition ShingleComments: Inspected
The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The typical life expectancy of asphalt shingle roofs in this climate is approximately 20 years, pleasebudget accordingly.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 13 of 56
2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).
Styles & Materials
Attic info:Scuttle hole
Attic inspected from:Inside the attic
Attic thermal insulation material:Blown-in Fiberglass
Approximate attic thermal insulationdepth:
R-19 or better
Roof Structure Ventilation:Attic ventilation appeared sufficient
Roof structure ventilation device type:Roof ventsSoffit vents
Roof Framing Type:Manufactured Roof Trusses
Roof Sheathing Material:1x4 spaced boardsPlywood
Items
2.0 Attic AccessComments: Inspected
2.1 Roof Framing (from attic)Comments: Inspected
2.2 Roof SheathingComments: Inspected
2.3 Roof Structure VentilationComments: Inspected
2.4 Attic ElectricalComments: Not Inspected
2.5 Venting Systems (Kitchens, Baths and Laundry)Comments: Inspected
2.6 Ventilation Fans and Thermostatic Controls in AtticComments: Not Inspected
I would recommend insulating theattic access panel for improved energyefficiency.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 14 of 56
2.7 Attic Rodent ActivityComments: Inspected
The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 15 of 56
3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Driveway Material:Asphalt
Walkway Materials:Concrete
Appurtenance:Deck with steps
Downspout Discharge:Above Grade
Lot Description:Moderate Slope
Clearance to Grade:Standard
Items
3.0 Exterior ViewsComments: Inspected
3.1 DrivewayComments: Inspected
(1) The driveway drains towards the garage. Please keep the drain-path clear for to ensure water doesnot flow towards the garage doors.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 16 of 56
3.2 WalkwaysComments: Inspected
3.3 General GroundsComments: Inspected
(2) I noted some root damage tothe asphalt driveway near the garagedoor and walk-way.
(1) This tree is very close to thefoundation. Some heaving of theconcrete sidewalk is noted.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 17 of 56
3.4 Exterior TrimComments: Inspected
3.5 PorchComments: Inspected
(2) Large trees overhead willrequired periodic cleaning of the roofof debris, needles, and leaves.
(1) Some minor rot is noted inthe trim adjacent to the front door. Iwould recommend removal andreplacement of affected components.These conditions are furtherconducive to wood destroyingorganisms.
(2) I noted some ant activity anddamage to the trim in this area on theright hand side of the garage. I wouldrecommend further assessment andtreatment by a licensed pest controloperator and repairs to the trim by aqualified contractor. These conditionsare further conducive to wooddestroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 18 of 56
3.6 Deck, Balcony, Bridge and Porch,Comments: Limitation
(1) Please note, I was unable to inspect the ledger detail or deck framing as it is not accessible.
I would recommend a coat of stain and/or preservative in order to maximize the remaining life-span of thisoutdoor deck.
(2) I would recommendextending the guard-rail as this area ofthe deck has an exposure greater than24 inches.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 19 of 56
3.7 Chimney Structure/ExteriorComments: Inspected
3.8 Additional StructuresComments: Not Inspected
(3) This step is constructed in atemporary fashion. I wouldrecommend a more permanentinstallation by a licensed deckingcontractor.
Chimney cap.
Shed - not inspected.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 20 of 56
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 21 of 56
4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Exterior wall-covering Material:Horizontal Lapped Wood Siding
Exterior Doors:Solid wood
Items
4.0 Door ExteriorsComments: Inspected
4.1 Window ExteriorsComments: Inspected
4.2 Wall FlashingComments: Inspected
4.3 Exterior Wall PenetrationsComments: Inspected
4.4 Exterior Wall MembraneComments: Inspected
4.5 Wood SidingComments: Inspected
(1) Rot has developed in thissection of siding due to pastdownspout leak. I would recommendverifying the downspout is no longerleaking and replace this section ofsiding. These conditions are furtherconducive to wood destroyingorganisms.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 22 of 56
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(2) I would recommend cleaningand repainting this section of sidingwhere some ivy was removed on theback of the home.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 23 of 56
5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.
Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.
Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.
Styles & Materials
Typical Ceiling Structure:Drywall attached to dimensional lumber
ceiling joistsDrywall attached to roof trusses
Exterior Wall Structures:Conventional 2x6 Wood Frame
Wall Insulation:Not Visible
Foundation Configuration:Crawlspace
Foundation Method/Materials:Poured concrete foundation walls
Main Floor Structure:Plywood sheathing over wood joists
Main Floor Structure- Perimeter Bearing:Rests on top of foundation wall
Main Floor Structure- IntermediateSupport:
Wood beam girderWood postsConcrete Piers
Floor System Insulation:BattsFiberglass
Evidence of Seismic Protection:None Noted
Crawl Space Vapor Barrier:6 Mil Poly
Items
5.0 Exterior Wall ConstructionComments: Inspected
5.1 Floor StructureComments: Inspected
5.2 Insulation Under Floor SystemComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 24 of 56
5.3 FoundationComments: Inspected
5.4 CrawlspaceComments: Inspected
No insulation exists in the laundry room ceiling, which is an unconditioned space. Additionally, the greatroom has no insulation above the drop ceiling. Consider insulating if these spaces are primarily keptunconditioned.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 25 of 56
(1) Considerable amounts of fras from an unidentified wood destroying insect are present in thecrawlspace along the foundation wall and framing below the living room adjacent to the front door. I did notnotice any active insect activity and did not note any visible structural damage. Further damage to the woodenstructure, if any, may exist and be concealed.
I would recommend further inspection and treatment as required by a licensed pest control operator.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 26 of 56
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(2) Approximately one half of the floor insulation has fallen from the floor above. The moisture barrier ismade of an older and thinner plastic than currently recommended.
I would recommend a general clean-up, insulation and moisture barrier replacement by a crawlspaceremediation contractor.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 27 of 56
6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.
The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting
Styles & Materials
Electrical Service Conductors:Underground serviceAluminum120/240 volt service
Service Panel Ampacity:125 amps
Service Panel Type:Load Center
Service Panel Manufacturer:Cuttler Hammer
Service Disconnect Location:At Service Panel
Service Disconnect Type:Breaker - Split Panel
Service Grounding Electrode:Not Visible
Wiring Methods:Romex
Type of Branch Wiring:Solid CopperStranded CopperStranded Aluminum
Ground Fault Circuit Interruptor (GFCI)Protection:
Partial
Arc Fault Circuit Interruptor (AFCI)Protection:
NO
Items
6.0 General Electrical System DescriptionComments: Inspected
6.1 General Electrical System ConditionComments: Inspected
6.2 Service Drop, Drip Loop, Splice and AttachmentComments: Inspected
6.3 Electric MeterComments: Inspected
6.4 Service Entrance ConductorsComments: Inspected
6.5 Service Panel ManufacturerComments: Inspected
6.6 Service Panel Exposure RatingComments: Inspected
6.7 Service Panel Cabinet, Ampacity, and CoverComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 28 of 56
6.8 Service Panel WiringComments: Inspected
This older style split panelelectrical panel does not have a singleisolation breaker. Consider replacingthis panel with a modern electricalpanel in the future.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 29 of 56
6.9 Service DisconnectComments: Inspected
6.10 Overcurrent Protection DevicesComments: Inspected
6.11 Service Grounding Electrode System & Service BondComments: Inspected
6.12 Equipment Grounding & BondingComments: Inspected
6.13 Exterior Electrical ReceptaclesComments: Inspected
6.14 Conventional Electrical Receptacles (interior)Comments: Inspected
6.15 GFCI/AFCI Electrical ReceptaclesComments: Inspected
Several circuit breakers in the main electrical panel are providing power to more than one branch circuit.I would recommend correction by a licensed electrician.
No ground fault circuit interrupter (GFCI) protection of homes kitchen, garage or exterior electricalreceptacles was provided in the home at the time of inspection. Although GFCI protection may not have beenrequired at the time the home was built, I recommend that electrical receptacles located in basements,
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 30 of 56
6.16 SwitchesComments: Inspected
6.17 LightingComments: Inspected
6.18 Visible Branch WiringComments: Inspected
6.19 Smoke DetectorsComments: Inspected
crawlspaces, garages, the home exterior, and interior receptacles located within 6 feet of a plumbing fixture beprovided with ground fault circuit interrupter (GFCI) protection for improved electrical safety.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 31 of 56
6.20 Carbon Monoxide DetectorsComments: Inspected
6.21 DoorbellComments: Inspected
The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
Smoke detectors arerecommended on each floor of thehome, in each bedroom of the home,outside common bedroom areas.Install in accordance withmanufactures recommend guidance orhire a licensed contractor for properinstallation.
Reference WAC 212-10-040:http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040
No carbon monoxide detectorswere installed. Carbon monoxidealarms must be located outside ofeach separate sleeping area, in theimmediate vicinity of the bedroom andon each level of the residence. Installin accordance with manufacturesrecommend guidance or hire alicensed contractor for properinstallation.
Reference WAC 51-51-315:http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 32 of 56
7. GarageInspection of the garage typically includes examination of the following:general structure; floor, wall and ceiling surfaces; operation of all accessibleconventional doors and door hardware; vehicle door condition and operation proper electrical condition including Ground Fault Circuit Interrupter(GFCI) protection; interior and exterior lighting; stairs and stairways proper firewall separation from living space; and proper floor drainage
Styles & Materials
Garage Vehicle Door Type:SingleDouble
Number of Vehicle Doors:2
Number of Automatic Openers:1
Vehicle Door Automatic Reverse:Failure to reverseNo photosensor
Auto-opener Manufacturer:SEARS
Items
7.0 Vehicle DoorsComments: Inspected
(1)1. The garage vehicle door failed to reverse when a reasonable amount of resistance was applied. The
Inspector recommends service by a qualified garage door contractor.2. No photoelectric sensors were installed. Photoelectric sensors are devices installed to prevent injury
by raising the vehicle door if the sensor detects a person in a position in which they may be injured bythe descending door. Installation of photo sensors in new homes has been required by generally-accepted safety standards since 1993. I woad recommend correction by a licensed garage doorcontractor.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 33 of 56
7.1 Conventional DoorsComments: Inspected
(2)1. Both vehicle doors have some delamination of the lower-most wood panel.2. I would recommend replacing the rubber threshold on both garage doors.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 34 of 56
7.2 FloorsComments: Inspected
7.3 WallsComments: Inspected
7.4 CeilingComments: Inspected
7.5 Fire SeparationComments: Inspected
7.6 Garage ElectricalComments: Inspected
7.7 General Condition and VentilationComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 35 of 56
8. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.
Styles & Materials
Walls and Ceilings:Drywall
Floor Covering Materials:CarpetSheet VinylViny Tile
Interior Doors:Wood Hollow Core
Window Material:WoodAluminum
Window Glazing:Double-pane
Window Operation:Sliding
Smoke/CO Detectors:Smoke detectors installedCarbon Monoxide detectors were not
installedAdditional smoke detectors
recommendedAdditional carbon monoxide detector(s)
required
Items
8.0 FloorsComments: Inspected
8.1 WallsComments: Inspected
8.2 CeilingsComments: Inspected
8.3 LightingComments: Inspected
8.4 Misc. Components: Ceiling fans, doorbells, Env. Hazards, Detectors, etc.Comments: Inspected
8.5 DoorsComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 36 of 56
(1) This door's handle is loose.
(2) The bedroom door does notlatch.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 37 of 56
8.6 Windows and SkylightsComments: Inspected
(3) I would recommend installingfloor mounted door guides to thekitchen pantry sliding doors.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 38 of 56
8.7 Interior TrimComments: Inspected
8.8 Cabinets and CountertopsComments: Inspected
8.9 StairsComments: Inspected
8.10 Bathroom and Laundry VentilationComments: Inspected
The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
The master-bedroom windowsare mounted very close to the floorand may pose a fall hazard if thewindows are open.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 39 of 56
9. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).
Styles & Materials
Water Supply Source:Public Water Supply
Main Water Supply Pipe:Not Visible
Main Water Supply Location:Not Located
Water Distribution Pipes:3/4-inch copper
Distribution Pipe Bonding:Pipes were bonded
Sewage System Type:Septic System - not inspected
Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)
Water Heater Manufacturer:American Standard
Date of Manufacture:Unable to determine
Water Heater Fuel Type:Electric
Water Heater Type:Tank (conventional)
Water Heater Tank Capacity:50 gallons
Water Heater Location:Garage
Washer Drain Size:2" Diameter
Gas Pipe Material:Black Steel
Type of Gas:Natural Gas
Items
9.0 Exterior PlumbingComments: Inspected
9.1 Source of WaterComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 40 of 56
9.2 Water Supply and DistributionComments: Inspected
9.3 Sewage and DWV SystemsComments: Inspected
9.4 Electric Water HeaterComments: Inspected
Please note, the main water cut-off valve is located in the crawlspacebelow the living room.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 41 of 56
(1) Please note, this older model water heater may have exceeded the typical life-span of 12 - 18 years.Consider a home warranty to mitigate repair/replacement costs. Budget for a replacement and the additionalinstallation of a surge tank in the future.
(2) Delivered hot watertemperature measured at the kitchensink was tepid at 104 deg F. I wouldrecommend servicing and adjustmentby a qualified contractor
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 42 of 56
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 43 of 56
10. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).
Styles & Materials
Heating System Type:Gas-fired Furnace (medium efficiency)
Energy Source:Natural gas
Number of Heat Systems (excludingwood):
One
Heating/Cooling Ducts:Partially insulated
Air Filter:Disposable
Air Filter Location:Inside blower compartment
Heating System Brand:Payne
Types of FIreplaces:Vented gas logs
Operational Fireplaces:One
Number of Woodstoves:None
Items
10.0 Presence of installed heat source in each roomComments: Inspected
10.1 FurnaceComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 44 of 56
(1) The furnace cabinet is visibly dirty with soot and combustion debris. I would recommend servicing bya licensed heating contractor and annually thereafter.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 45 of 56
10.2 Fuel, Piping and SupportComments: Inspected
10.3 ThermostatComments: Inspected
10.4 Filter conditionComments: Inspected
10.5 FireplaceComments: Inspected
(2) This older model furnace(1975) has exceed it's typical lifeexpectancy of 16 - 20 years. I wouldrecommend you budget for areplacement unit.
The fireplace glass is visibly dirtyand the flame more diffuse than I amtypically used to seeing. I wouldrecommend servicing by a qualifiedcontractor.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 46 of 56
The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 47 of 56
11. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation
Styles & Materials
Exhaust Fans:Fan only
Items
11.0 FloorsComments: Inspected
11.1 WallsComments: Inspected
11.2 CeilingsComments: Inspected
11.3 DoorsComments: Inspected
11.4 WindowsComments: Inspected
11.5 Electrical Receptacles and SwitchesComments: Inspected
11.6 LightingComments: Inspected
11.7 VentilationComments: Inspected
11.8 CabinetsComments: Inspected
11.9 ToiletComments: Inspected
11.10 ShowerComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 48 of 56
11.11 Medicine CabinetComments: Inspected
11.12 MirrorsComments: Inspected
11.13 SinkComments: Inspected
(1) The shower surround in the hall bathroom requires cleaning and caulk replacement. Some bucklingof the tile is noted at the foot of the tub.
(2) The showerhead in the hallbathroom requires replacement.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 49 of 56
The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 50 of 56
12. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.
Styles & Materials
Cabinets:Solid Wood
Countertop Material:Laminate
Range:Electric
Range/Oven Brand:Kenmore
Range Hood:Vents to exterior
Range Hood Brand:Broan
Dishwasher:Present, Inspected
Dishwasher brand:Frigidair
Dishwasher Anti-siphon method:Air gap installed
Garbage Disposal brand:Kenmore
Refrigerator:Present, not inspected
Refridgerator Brand:JcPenny
Items
12.0 FloorsComments: Inspected
12.1 WallsComments: Inspected
12.2 CeilingsComments: Inspected
12.3 DoorsComments: Inspected
12.4 WindowsComments: Inspected
12.5 SkylightsComments: Inspected
12.6 Interior TrimComments: Inspected
12.7 Receptacles and SwitchesComments: Inspected
12.8 LightingComments: Inspected
12.9 CabinetsComments: Inspected
12.10 Kitchen AppliancesComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 51 of 56
Consider purchasing a home warranty that covers your kitchen and other appliances to mitigate anynear-term repair or replacement costs considering their age.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 52 of 56
12.11 RangeComments: Inspected
12.12 Range HoodComments: Inspected
12.13 Garbage DisposalComments: Inspected
12.14 DishwasherComments: Inspected
12.15 CounterComments: Inspected
12.16 SinkComments: Inspected
The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 53 of 56
13. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.
Styles & Materials
Dryer Power:Electric
Dryer Vent:Smooth-bore metal
Dryer 240-volt electrical receptacle:Installed
Dryer Gas Supply:Not Visible
Items
13.0 FloorsComments: Inspected
13.1 WallsComments: Inspected
13.2 CeilingsComments: Inspected
13.3 DoorsComments: Inspected
13.4 WindowsComments: Inspected
13.5 SkylightsComments: Not Inspected
13.6 Receptacles, Switches, ConnectionsComments: Inspected
13.7 LightingComments: Inspected
13.8 CabinetsComments: Inspected
13.9 Dryer VentingComments: Inspected
13.10 Washer/DryerComments: Not Inspected
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 54 of 56
The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
Washer/dryer.
NW WASHINGTON HOME INSPECTIONS LLC Farrow
504 Cantershire Pl BE Page 55 of 56