6
Photo/isometric drawing provided by manufacturer fermacell® gypsum fibreboard Description of Product This is an assessment of fermacell® gypsum fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system achieves 60 minutes fire resistance and can be used to assist in sound separation between dwellings. fermacell is formed using recycled gypsum from coal fired power stations and recycled paper. The system comprises a 15mm thick fermacell® gypsum fireboard fixed with both sides of timber frame manufactured by others having 70 x 44mm minimum timber size. Key Factors Assessed Safety in case of Fire Health, Hygiene and Environmental Protection against noise Validity This certificate was first issued on 12 th September 2019 and is valid until 12 th September 2020 Issue Dated 12 th September 2019 Certificate No: EWW1183

fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

Photo/isometric drawing

provided by manufacturer

fermacell® gypsum fibreboard

Description of Product

This is an assessment of fermacell® gypsum

fibreboards applied one layer each side for use

in non-habitable roof spaces for use in single

skin Spandrel Panels. The system achieves 60

minutes fire resistance and can be used to

assist in sound separation between dwellings.

fermacell is formed using recycled gypsum

from coal fired power stations and recycled

paper.

The system comprises a 15mm thick

fermacell® gypsum fireboard fixed with both

sides of timber frame manufactured by others

having 70 x 44mm minimum timber size.

Key Factors Assessed

Safety in case of Fire

Health, Hygiene and Environmental

Protection against noise

Validity

This certificate was first issued on 12th September 2019 and is valid until 12th September 2020

Issue Dated 12th September 2019

Certificate No: EWW1183

Page 2: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

Fixing

Phosphate coated fermacell 3.9 x 40mm fermacell™ screws at 250mm centres.

Alternatively 48 x 10 x 1.5mm galvanised staples can be used for fixing at 200mm centres.

If 89 x 38mm timbers are used an 18mm board is required, fixing details are to be obtained from the fermacell technical

department.

fermacell board must be fixed to the small face of timber only. If nail plates are used on timber frame they must be a

minimum 1mm thick with minimum 8mm long nails fixed to each face of the timbers and CE marked to EN 14545:2008.

Joints

Standard sheeting joints are tight dry-butt joint. Gaps require fire mastic or 150mm cover strip of fermacell with 55mm

fermacell™ screws into each timber at 250mm centres and 55mm long skew fixings to connect panels (see fermacell

brochure for details.)

Fire resistance

The spandrel panel in effect forms a barrier in the concealed space which is non-loadbearing but will provide resistance to

penetration (integrity) and resistance to transfer of excessive heat (insulation) for a period of 62 minutes proven in test to BS

476: Part 22:1987 which exceeds the recommended 60 minutes in table A2 of Approved Document B.

Sound

fermacell® gypsum fireboard can be used with Robust Details Walls to conform to AD E. Panels are now part of Appendix A

in Robust Details as an accepted solution. The supporting blockwork should extend 300mm minimum above finished ceiling

level with the cavity wall closed with a proprietary cavity stop. The junction between the spandrel panel and supporting

blockwork is to be sealed with flexible or acoustic sealant or mounted on a layer of mineral wool.

Installation to be in strict accordance with manufacturer’s instructions, guides and recommendations.

Page 3: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

For LABC Warranty purposes:

1. BBA certificate 90/2439 PS1 must remain valid 2. The product must be installed in strict accordance with the BBA certificate

3. The product is suitable for use in single skin spandrel panels installed as a separating wall in non-habitable roof spaces,

subject to:

a) Timber frame/trussed rafter manufacturer holding ISO9001 or equivalent Quality Management System.

b) Installation must be in accordance with Robust Details. c) Joints between panels must be protected by an additional cover

strip.

c) The board must be fixed to the timber frame in accordance with Fermacell specifications.

Page 4: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

LABC consider that, fermacell® gypsum fibreboard will meet the functional requirements of the

Building Regulations (listed below) if the criteria detailed in this certificate are met;

The Building Regulations 2010 (as amended) England & Wales

AD B Fire Safety

Note: The product is acceptable as per the Scope of Registration and Conditions of

Certificate.

AD E Resistance to the passage of sound

Note: The product is acceptable as per the Scope of Registration and Conditions of

Certificate.

The Building Regulations 2010 (as amended) England

AD B Fire Safety

Note: The product is acceptable as per the Scope of Registration and Conditions of

Certificate.

The Building Regulations 2010 (as amended) Wales

AD B Fire Safety

Note: The product is acceptable as per the Scope of Registration and Conditions of

Certificate.

The Building (Scotland) Regulations 2004 (as amended)

Pending assessment.

Page 5: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

LABC Warranty

LABC Warranty conditionally accepts the use of fermacell® gypsum fibreboard when installed and used

in accordance with the Scope and Conditions of this Certificate. Visit www.labcwarranty.co.uk for our

LABC Warranty Technical Manual requirements and Warranty conditions of acceptance.

Confirmation NHBC Spandrel Panel

392457-Exova Assessment- Spandrel Panel ancillary performance details-issue 2

Fermacell Brochure Spandrel Panel 2018

RDL Appendix A1

Spandrel Fire Test Report 385716 condensed V3 01-2018

Page 6: fermacell® gypsum fibreboard - LABC · 2019-12-18 · fibreboards applied one layer each side for use in non-habitable roof spaces for use in single skin Spandrel Panels. The system

Fermacell UK, Branch of James Hardie Europe GmbH

7 The Priory

Old London road

Canwell

West Midlands

B75 5SH

Tel: 0121 311 3480

Email: [email protected]

Web: www.fermacell.co.uk