Upload
walter-r-schulz
View
222
Download
0
Embed Size (px)
Citation preview
8/10/2019 FG_Construction Documents_07-003.pdf
1/19
8/10/2019 FG_Construction Documents_07-003.pdf
2/19
8/10/2019 FG_Construction Documents_07-003.pdf
3/19
8/10/2019 FG_Construction Documents_07-003.pdf
4/19
8/10/2019 FG_Construction Documents_07-003.pdf
5/19
8/10/2019 FG_Construction Documents_07-003.pdf
6/19
8/10/2019 FG_Construction Documents_07-003.pdf
7/19
8/10/2019 FG_Construction Documents_07-003.pdf
8/19
16 DN A-01-12
Right
A-01-1
A-01-2
A-01-2
1Rear
2
Left
1Front
1
1 1 1
3 1 1
1
2
1
1
42' - 0"
4' - 6" 7' - 0" 6' - 0" 7' - 0" 6' - 0" 7' - 0" 4' - 6"
42' - 0"
4' - 6" 7' - 0" 6' - 0" 7' - 0" 6' - 0" 7' - 0" 4' - 6"
32'-0"
7'-111/2"
R.O.
3'-1"
9'-11"
R.O.
3'-1"
7'-111/2"
32'-0"
7'-111/2"
R.O.
3'-1"
9'-11"
R.O.
3'-1"
7'-111/2"
1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2" 1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2" 1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2"
1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2" 1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2" 1' - 11 1/2"
R.O.
3' - 1"
1' - 11 1/2"
2-6x6-8
2-6x6-8
2-6x6-8
2-6x6-8
2-6x6-8
2-6x6-8
3-0x6-8 3-0x6-8 3-0x6-83-0x6-8
BATH 2 BATH 1
BED 1
BED 2
BED 3
WALL LEGEND
NOTE:
DIMENSIONS TO EXTERIOR WALLSREFERENCE FACE OF STUD.
DIMENSIONS TO INTERIORPARTITIONS REFERENCE CENTEROF 2x4 OR 2x6 STUD.
2x4 OR 2x6 STUD WALLOR 2x_ RAFTERSW/ INSULATION
2x4 OR 2x6 STUD WALLUN-INSULATED
4'-5
3/4"
11'-61/4"
10'-61/4"
2'-41/2"
3'-11/4"
16' - 9" 7' - 7" 16' - 9"
10' - 8 3/4"
6' - 0 1/4"
9' - 2 1/2" 2' - 4 1/2" 12' - 9"
ALIGNED TO END
ALIGNED TO END
2
3
3
TEMPERED
TEMPERED
EGRESS EGRESS
EGRESS
4
5
READINGNOOK
D
D
D
D
1
A-03-1
2
A-03-1
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
NOTES:
REVISION SCHEDULE:
348 MEDFORD ST. SUITE 1CHARLESTOWN, MA 02129
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
www.FreeGreen.com
1/4" = 1
A-02-2
UPPER LEVELFLOOR PLAN
07-0
SEASIDE BARN
07 APRIL, 20
BU,
D = COMBINA TION SMOKE & CARBON MONOXIDE DETECTOR DETECTORS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY BEDROOMS AND ON EACH STORY OF THE DWELLING INCLUDING BASEMENTS. ALL DETECTORS SHALL BE CONNECTED TO A SOUNDING DEVICE OR OTHER DETECTORS TO PROVIDE AN ALARM AUDIBLE IN ALL SLEEPING AREAS. ALL DETECTORS SHALL BE APPROV AND LISTED AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
FLOOR TO FLOOR HEIGHTS WILL VARY BASED ON DEPTH OFLOOR FRAMING AS DETERMINED BY STRUCTURALENGINEER. STAIR RISERS MUST NOT EXCEED 7 3/4", STAITREADS MUST NOT BE LESS THAN 10" AS PER IRC 2006.
WALL MOUNT STAIR RAIL. MAX PROJECTION MUST NOTEXCEED 4 1/2" FROM FACE OF FINISH WALL AS PER IRC 20
1
2
No. Description Dat
1/4" = 1'-0"1
UPPER LEVEL FLOOR PLAN
PROVIDE TEMPERED GLASS SHOWER ENCLOSURE.3
PROVIDE STATIONARY LADDER UP TO READING NOOK.4
SAFTY RAILS REQUIRED IN READING NOOK. TOP RAIL TO BMIN OF 36" ABOVE T.O. FINISH FLOOR.
5
8/10/2019 FG_Construction Documents_07-003.pdf
9/19
T.O. FOOTING EL: (-) 5'-0" (OR AS REQ)
T.O. FOUNDATION WALL EL: (-) 1'-3"
T.O. ENTRY LEVEL SUB FLR EL: 0'-0"
B.O. FLOOR FRAMING EL: 9'-1"
T.O. UPPER LEVEL SUB FLR EL: 10'-1"
T.O. GABLE WALL PANEL EL: 17'-2"
B.O. CEILING JOISTS / RAFTER TIES EL: 18'-2"
T.O. RIDGE RAFTER EL: +/- 24'-5 1/8"
+/-24'-51/8"V.I.F.
8'-1"
10'-1"
(-)5'-0"
1'-3"
9'-1"
1'-0"
1'-0"
7'-1"
+/-6'-31/8"V.I.F.
T.O. BEAM EL: 8'-4 1/8" ABOVET.O. ENTRY LEVEL SUB FLR
PT BEAM AS REQ W/ 1/2" CEDAR COVER BOARDS
6x6 POST ON GALV STEEL POSTANCHOR TYPICAL TO EXTERIOR
12" DIA CONC SUPPORTW/ FOOTING BELOWFROST DEPTH TYP (OR AS REQ)
6
12
6
12
20
12
20
12
312
312
DECK CONSTRUCTION: (TOP DOWN)TROPICAL HARDWOOD, PT WOOD OR COMPOSITE DECKING -
2x8 PT DECK JOISTS @16" O/C -
MASONRY CHIMNEY
DECK RAILS @36" MIN ABOVE DECK SURFACE
CRAWL SPACE- CONDITIONED CRAWL SPACE- SPRAY FOAM INSULATION ON INSIDE OFPERIMETER WALLS W/ IGNITION BARRIER- CONT POLYETHYLENE VAPOR BARRIER- COMPACTED SOIL
S PR AY FO AM IN SU LA TI ON W/ IG NI TI ON BA RR IE R C ON T P OL YE TH YL EN E V AP OR BA RR IE R
3/4" T&G SHEATHING OVER11 1/4" OPEN WEB FLR TRUSS
3/4" T&G SHEATHING OVER11 1/4" OPEN WEB FLR TRUSS
RAISED HEARTH
A-05-43
A-05-44
7' - 8 1/2"
36"
5'-01/2"
V.I.F.
5'-01/2"
3'-0"
1 2
3
4
16 UP
T.O. ENTRY LEVEL SUB FLR EL: 0'-0"
T.O. UPPER LEVEL SUB FLR EL: 10'-1"
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
NOTES:
REVISION SCHEDULE:
348 MEDFORD ST. SUITE 1CHARLESTOWN, MA 02129
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
www.FreeGreen.com
1/4" = 1
A-03-1
BUILDING SECTIONS
07-0
SEASIDE BARN
07 APRIL, 20
BU,
No. Description Dat
1/4" = 1'-0"1 SECTION 1
1/4" = 1'-0"
2STAIR SECTION
FLOOR TO FLOOR HEIGHTS WILL VARY BASED ON DEPTH OFLOOR FRAMING AS DETERMINED BY STRUCTURALENGINEER. STAIR RISERS MUST NOT EXCEED 7 3/4", STAITREADS MUST NOT BE LESS THAN 10" AS PER IRC 2006.
WALL MOUNT STAIR RAIL. MAX PROJECTION MUST NOTEXCEED 4 1/2" FROM FACE OF FINISH WALL AS PER IRC 20
1
2
PROVIDE STATIONARY LADDER UP TO READING NOOK.3
SAFTY RAILS REQUIRED IN READING NOOK. TOP RAIL TO BMIN OF 36" ABOVE T.O. FINISH FLOOR.
4
8/10/2019 FG_Construction Documents_07-003.pdf
10/19
8/10/2019 FG_Construction Documents_07-003.pdf
11/19
8/10/2019 FG_Construction Documents_07-003.pdf
12/19
8/10/2019 FG_Construction Documents_07-003.pdf
13/19
8/10/2019 FG_Construction Documents_07-003.pdf
14/19
8/10/2019 FG_Construction Documents_07-003.pdf
15/19
8/10/2019 FG_Construction Documents_07-003.pdf
16/19
D
D
3
3 3
3
3
3 3
S
R
M
M
GFI-WP
GFI-WP
GFI
GFI
GFI
240
A-01-12
Right
A-01-1
A-01-2
A-01-2
1Rear
2
Left
1Front
42' - 0"
32'-0"
42' - 0"
32'-0"
17' - 4 1/4" 7' - 3 1/2" 17' - 4 1/4"
7'-53/4"
8'-41/2"
16'-13/4"
FRAMING PAGE LEGEND
COLUMN SUPPORT BELOW
POINT LOAD FROM ABOVE
PLUMBING DROP
OPEN WEB FLOOR TRUSS
WOOD BEAM
STEEL BEAM
STRUCTURAL FRAMINGMEMBER AS NOTED
2x_ SOLID BRIDGING
LOAD BEARING PARTITION
JOIST OR BEAM HANGER
BOTTOM CHORD BEARING 11 1/4" OPEN WEB TRUSSES@16" O/C OR AS REQ PER STRUCTURAL ENGINEER
2x12 RIM JOIST2x12 RIM JOIST
2x12 RIM JOIST2x12 RIM JOIST
DBL 2x12 RIM JOIST
DBL 2x12 RIM JOIST
1 1
BEAM AS REQ BEAM AS REQ
T.O. BEAM EL: 8'-4 1/8" ABOVET.O. ENTRY LEVEL SUB FLR
PT BEAM AS REQ W/ 1/2" CEDAR COVER BOARDS
T.O. BEAM EL: 8'-4 1/8" ABOVET.O. ENTRY LEVEL SUB FLR
PT BEAM AS REQ W/ 1/2" CEDAR COVER BOARDS
BEAM AS REQ
BEAM AS REQ
6'-0"
6'-0"
5 1/2"41' - 1"
5 1/2"
6'-0"
6'-0"
5 1/2"41' - 1"
5 1/2"
1
A-03-1
2
A-03-1
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
GENERAL:
THE FRAMING LAYOUT ON THIS PAGE IS INTENDED TO BE ASUGGESTED LAYOUT ONLY. DESIGN LOADS & WEATHERCONDITIONS VARY BY REGION. AS A RESULT THE SIZE, SPACINGLAYOUT OF ALL STRUCTURAL ELEMENTS IN THIS HOME DESIGNMUST BE APPROVED BY A STRUCTURAL ENGINEERAND CODEOFFICIAL BASED ON YOUR SPECIFIC SITE LOCATION PRIOR TOCONSTRUCTION.
REVISION SCHEDULE:
348 MEDFORD ST. SUITE 1CHARLESTOWN, MA 02129
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
www.FreeGreen.com
MATERIAL SPECIFICATIONS: ( VERIFY W/ LOCAL CODE)
FLOOR SHEATHING:3/4" APA-RATED EXPOSURE 1, T&G,48/24 SPAN RATING, EXPOSURE 110d COMMON NAILS @6" O/C B.N. & E.N.,10d COMMON NAILS @10" O/C INT. FRAMING
ROOF SHEATHING:5/8" APA-RATED EXPOSURE 1,24" MINIMUM SPAN RATING,8d COMMON NAILS @6" O/C B.N. & E.N.,8d COMMON NAILS @10" O/C INT. FRAMING
SAWN STRUCTURAL FRAMING MEMBERS:MEMBERS GRADE2x_ WALL STUDS D.F. #22x_ FLOO R JOI ST S & RO OF RA FT ER S D .F . #2BEAMS & HEADERS D.F. #1
POSTS (4x,6x,8x) D.F. #1
WOOD BEAM MINIMUM ALLOWABLE BENDING STRESS:MEMBERS Fb (PSI)GLUED LAMINATED TIMBERS 2400LAMINATED VENEER LUMBER 2700
INTERIOR HEADERS:INTERIOR NON-BEARING SPANS USE:2x4 FLAT FOR SPANS UP TO 3'-0"4x4 D.F. #2 FOR SPANS UP TO 5'-0"4x6 D.F. #2 FOR SPANS UP TO 8'-0"
NOTES:
1/4" = 1
A-05-3
UPPER LEVEL FLRFRAMING PLAN
07-0
SEASIDE BARN
07 APRIL, 20
BU,
No. Description Dat
1/4" = 1'-0"1
UPPER LEVEL FLOOR FRAMING PLAN
1 PROVIDE 2x6 SOLID BRIDGING. SE CURELY FASTEN AT EATRUSS AND AT END WALLS.
8/10/2019 FG_Construction Documents_07-003.pdf
17/19
8/10/2019 FG_Construction Documents_07-003.pdf
18/19
16% OFWINDOWHEIGHT
D
H
16% OFWINDOWHEIGHT
D
H
H
D
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
ABOUT THIS PAGE:
EXTERNAL WINDOW SHADING DEVICES ARE AN EFFECTIVE METHFOR REDUCING HEAT GAINS THROUGH WINDOWS DURING SUMMIN FACT, EXTERNAL SHADING DEVICES CAN REDUCE HEAT GAINSUP TO 80% IF SIZED AND BUILT PROPERLY. WI TH THIS IN MIND,FREEGREEN HAS CREATED THIS PAGE TO ASSIST HOME BUILDERCONSTRUCTING EFFECTIVE WINDOW SHADING DEVICES. THEINFORMATION WE PROVIDE INCLUDES A ZONING MAP OF THE UNSTATES, ZONING CHARTS FOR PROPER SIZING OF SHADING DEVAND A VARIETY OF SHADING DEVICE STYLES AND MATERIALS TOSUITE DIFFERENT TASTES AND DIFFERENT HOME DESIGNS.
REVISION SCHEDULE:
348 MEDFORD ST. SUITE 1CHARLESTOWN, MA 02129
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
www.FreeGreen.com
OVERHANGDEPTH(ZONE4)
OVERHANGDEPTH(ZONE2)
OVERHANGDEPTH(ZONE3)
OVERHANGDEPTH
(ZONE1)
OVERHANGDEPTH(ZONE5)
STEP 1: FIND YOUR ZONESTEP 2: FROM THE TABLE, DETERMINE OVERHANG DEPTH FOR YOUR WINDOWSSTEP 3: CHOOSE YOUR WINDOW SUN SHADING DEVICESTEP 4: CHOOSE YOUR MATERIALS
OVERHANG DEPTH (INCHED), D
WINDO
WH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),
H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDO
WH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
1" = 1
A-06-1
WINDOW SHADINGDETAILS
07-0
SEASIDE BARN
07 APRIL, 20
Aut
Chec
MATERIAL SPECIFICATION:
WOOD TYPES:
PRES SUR E TREA TED WE STER N RE D CE DAR TROPICAL HARDWOOD (FSC CERTIFIED REQUIRED)
MAHOGANY M AS SA RA ND UB A
HARDWARE:
ALL HARDWARE MUST BE EITHER HOT DIPPED GALVANIZEDSTEEL OR STAINLESS STEEL. FREEGREEN RECOMMENDSONLY STAINLESS STEEL FOR HOUSE LOCATIONS IN CLOSEPROXIMITY TO THE OCEAN.
FINISHES:
IF USING PRESSURE TREATED WOOD SEAL & FINISH TO MATCHEXTERIOR WINDOW TRIM.
IF USING WESTERN RED CEDAR SEAL & FINISH TO MATCHEXTERIOR WINDOW TRIM
IF USING TROPICAL HARDWOOD FINISH MAY NOT BE REQUIREDSEALING AND FINISHING OF TROPICAL HARDWOODS WILLVARY BY SPECIES. CONS ULT WITH YOUR PROVIDER FORRECOMMENDED FINISHES FOR ALL TROPICAL HARDWOODPRODUCTS.
1" = 1'-0"1
BENCH WINDOW SHADING DEVICE
1" = 1'-0"2
BENCH WINDOW SHADING DEVICE
1" = 1'-0"3
BENCH WINDOW SHADING DEVICE
No. Description Dat
8/10/2019 FG_Construction Documents_07-003.pdf
19/19
240
GFI
GFI-WP
M
R
UC
S
3
D
F
2
16 UP
D
D
3
3 3
3
3
3 3
S
R
M
M
GFI-WP
GFI-WP
GFI
GFI
GFI
240
16 DN3
GFI
GFI
GFI
ELECTRICAL OUTLET LEGEND
110VRECEPTICAL
SWITCHRECEPTICAL
GROUND FAULT CURRENTINTERRUPTER RECEPTACLE
GFI AND WATER PROOFRECEPTACLE
MICROWAVE OVENRECEPTICAL
RANGERECEPTICAL
UNDER COUNTERRECEPTICAL
240VRECEPTICAL
110V FLOORRECEPTICAL
ELECTRICAL SWITCH LEGEND
LIGHT SWITCH
DOUBLE LIGHT SWITCH
KEY ROOMMASTER CONTROL
KEY SCENEMASTER CONTROL
GRAPHIC EYE
3-WAY LIGHT SWITCH
DIMMER LIGHT SWITCH
OCCUPANCY SENSORFAN SWITCH
KR
KS
G
LIGHTING LEGEND
RECESSED DOWN LIGHTENERGY STAR RATED
CEILING BOX
BATHROOM EXHAUST FAN
WALL MOUNTED FIXTURE
RECESSED WALL WASHER
RECESSED ACCENT
DIRECTIONAL
RECESSED GLASS
F
RD
RW
RA
RG
RD-ES
RECESSED DOWN LIGHT
LED LINEAR
IN-WALL LED STEP LIGHTW/ REMOTE TIMER CONTROL
FLUORESCENT STRIP
DRBL
CHIME
TEL
H20
#C#P
MICELANEOUS ELECTRICAL SYMBOL LEGEND
SMOKE & CARBONMONOXIDE DETECTOR
DOOR BELL
DOOR BELL CHIME
ICE MAKER
NATURAL GAS/PROPANEHOOKUP
MULTIMEDIA JACK(NETWORK/TV)
TELEPHONE JACK
THERMOSTAT
CEILING FAN
T
D
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
WH240V OR GAS INSTALLATIONTANKLESS WATER HEATER
D
D
RD-ES
RD-ES
RD-ES
RD-ES
RD-ES
RD-ES
RD
RD
RD
RD
RD
#C#P
#C#P
F
WH
CHIME
DRBL
TEL
T
H20
D
D
D
D
RD RD
RD F
RD F
RD
#C#P
#C#P
#C#P
RD
T
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
NOTES:
REVISION SCHEDULE:
348 MEDFORD ST. SUITE 1CHARLESTOWN, MA 02129
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
www.FreeGreen.com
1/4" = 1
E-01-1
ELECTRICAL PLAN
07-0
SEASIDE BARN
07 APRIL, 20
BU,
1/4" = 1'-0"ELECTRICAL SYMBOL LEGEND
No. Description Dat
1/4" = 1'-0"1
ENTRY LEVEL ELECTRICAL PLAN
1/4" = 1'-0"2
UPPER LEVEL ELECTRICAL PLAN