33
Fiber to the Antenna Fiber Certification Summer 2018

Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

  • Upload
    others

  • View
    5

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

Fiber to the Antenna

Fiber Certification

Summer 2018

Page 2: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

2© 2018 Viavi Solutions Inc.www.viavisolutions.com

FTTA Installation Webinars

• Fiber Inspection and Connectivity• Cable and Antenna Test• Fronthaul Installation Test• Fiber Certification

For more information, visit viavisolutions.com/ftta

Page 3: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

3© 2018 Viavi Solutions Inc.www.viavisolutions.com

Fiber Up the Tower – Interconnects

BBU and Fiber Patch Panel

Junction Box

RRU/RRH

Fiber Trunk Cable

Tx & Rx Fibers

RRU/RRH Jumper

RRU = Remote Radio UnitRRH = Remote Radio HeadBBU = Base Band Unit

Front haul Physical Layer CharacteristicsFiber Type : Singlemode or MultimodeConnector Type: Duplex LC/PC

Page 4: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

4© 2018 Viavi Solutions Inc.www.viavisolutions.com 4© 2017 Viavi Solutions Inc.www.viavisolutions.com

Inspection

Page 5: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

5© 2018 Viavi Solutions Inc.www.viavisolutions.com

Inspect Before You Connect!Fiber inspection/cleaning of the patch cord and bulkhead sides are SIMPLE steps with immense benefits. Connectors behind the bulkhead are frequently dirty and problematic.

4 Connect2 Clean1 Inspect 3 Re-inspect

SUBJECTIVE INSPECTION

???

2.4um

3.0um

8.6um

FAIL

OBJECTIVE INSPECTION

IEC 61300-3-35 Sets Requirements for Connector Quality

Dirt, oil, pits, scratchesnot seen

VS

VS

• Tools need to be automated and adhere to the defined standards• Move away from subjective to objective assessment

Page 6: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

6© 2018 Viavi Solutions Inc.www.viavisolutions.com 6© 2017 Viavi Solutions Inc.www.viavisolutions.com

MPO

Page 7: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

7© 2018 Viavi Solutions Inc.www.viavisolutions.com

First – What is MPO?

MPO (Multi-fiber Push On) is a connector for ribbon cables with 12 to 96 fibers (field usage is 12 or 24 fibers). Connectors for singlemode fiber have angled ends to minimize back-reflection, while multimode fiber versions typically have flat ends.

Fan-out/Break-out MPO cableOR native support in SFP

Page 8: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

8© 2018 Viavi Solutions Inc.www.viavisolutions.com

Fiber Plug & Play or Plug & Pray?

Particle of Dirt

Air Gap

1

2

3

45

6

7

8

9

1011

12

Dirt

Back Reflection

Insertion Loss

CONTAMINATION is the #1 source of troubleshooting in optical networks.

Responsible for around 80% of failures

Page 9: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

9© 2018 Viavi Solutions Inc.www.viavisolutions.com 9© 2017 Viavi Solutions Inc.www.viavisolutions.com

Insertion Loss (IL)

Page 10: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

10© 2018 Viavi Solutions Inc.www.viavisolutions.com

Insertion Loss (IL)• IL testing assesses how much optical power is lost across an optical link. If there is too

much link loss, an optical receiver (SFP or QSFP) will not function correctly. • Losses are due to fiber losses, splice and connector losses• When testing MM fiber, LS must be encircled flux compliant • Referencing (or zeroing) is key for accurate or realistic results

- Takes out losses due to patch cords leaving only the fiber of the installation• Design docs will specify total allowable link loss (or link budget) that cannot be exceeded

Light Source Power MeterPin

Pout

IL (dB) = Pin (dBm) – Pout (dBm)

Page 11: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

11© 2018 Viavi Solutions Inc.www.viavisolutions.com

A Word On Referencing

Tx FiberRx Fiber

Loopback Device

Light Source

Power Meter

1 cord reference

3 cord reference(using loopback device as 3rd cord)

jumper cords/cables – reference fibers are best

Light Source

Power Meter

1

1 2

LS PM

LS

PM

Page 12: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

12© 2018 Viavi Solutions Inc.www.viavisolutions.com

Causes of IL• Contributors to link loss include fiber attenuation and loss through mated

connectors or splices. - Contaminated, damaged, or poorly mated connectors are the most common

sources for excess link loss (~80%). - Stress on the fiber by over-bending, pinching, or kinking (typically found in

RRU enclosures, junction boxes and fiber trays) is also a frequent source of problems. Microbend loss

Macrobend loss

Page 13: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

13© 2018 Viavi Solutions Inc.www.viavisolutions.com 13© 2017 Viavi Solutions Inc.www.viavisolutions.com

Optical Return Loss (ORL)

Page 14: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

14© 2018 Viavi Solutions Inc.www.viavisolutions.com

Optical Return Loss (ORL)• ORL is the ratio of reflected to transmitted optical power levels for the end-to-end

fiber link. This represents the combined amount of reflected light from all the link components - connectors, splices plus the Rayleigh backscattering from the fiberitself.

• ORL usually only measured on SM fibers• Flat connectors will need terminating • Angled connector doesn’t need any termination

ORL (dB) = 10Log (PT/PB) (≥0)

PAPC PPC PAPC PAPC

PT

PF PF PF

ORL Meter(CombinedLS & PM)

PT: Output power of the light source

PAPC: Back-reflected power of APC connector

PPC: Back-reflected power of PC connector

PF: Backscattered power of fiber

PB: Total amount of back-reflected power

Page 15: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

15© 2018 Viavi Solutions Inc.www.viavisolutions.com

Causes of ORL• The largest contributor to reflected optical power is air gaps and connectors.

Exceeding ORL limits can cause data errors, increase system noise, and can sometimes damage transmitters in higher-power environments.

Page 16: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

16© 2018 Viavi Solutions Inc.www.viavisolutions.com 16© 2017 Viavi Solutions Inc.www.viavisolutions.com

Optical Time Domain Reflectometry (OTDR)

Page 17: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

17© 2018 Viavi Solutions Inc.www.viavisolutions.com

OTDR Testing & Certification It’s the single most important tester used in the installation, maintenance & troubleshooting of fiber plant

T-BERD/MTS-2000 OTDR with FTTA-SLM

Most versatile of Fiber Test Tools• Detect, locate and measure events at any location on the

fiber link• Identifies events & impairments (splices, bends,

connectors, breaks)• Provides physical distance to each event/ impairment• Measures fiber attenuation loss of each event or

impairment• Provides reflectance / return loss values for each reflective

event or impairment• Manages the data collected and supports data reporting

Page 18: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

18© 2018 Viavi Solutions Inc.www.viavisolutions.com

OTDR Testing & Certification

Tx Feeder

Receive Lead

Rx Feeder

Launch Lead

Loopback Device

AB

CD

E F

Page 19: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

19© 2018 Viavi Solutions Inc.www.viavisolutions.com

Interpreting OTDR traces with Smart Link Mapper (SLM)Making OTDR results easy to read

Dedicated FTTA-SLM

Page 20: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

20© 2018 Viavi Solutions Inc.www.viavisolutions.com 20© 2017 Viavi Solutions Inc.www.viavisolutions.com

Wavelength Division Multiplexing (WDM)

Page 21: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

21© 2018 Viavi Solutions Inc.www.viavisolutions.com

Types of WDM Networks

CWDM channels are spaced 20 nm apart DWDM channels are spaced ~0.4 to 0.8 nm apart

DWDM enables a much higher density, therefore a better usage of the fiber

8 CWDM Channels in the S+C+L band

Wavelength

Up to 96 DWDM Channels in the C Band

18 CWDM Channels

Page 22: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

22© 2018 Viavi Solutions Inc.www.viavisolutions.com

DWDM over CWDM Channel Expansion

DWDM

1550 nm

1570 nm

1510 nm

1530 nm

1590 nm

1490 nm

1470 nm

1610 nm

1550 nm

DWDMCW

DM

1547.72 nm

1548.51 nm

1549.32 nm

1550.12 nm

1550.92 nm

1551.72 nm

1552.52 nm

1553.33 nm

1570 nm

1510 nm

1530 nm

1590 nm

1490 nm

1470 nm

1610 nmCW

DM

1547.72 nm

1548.51 nm

1549.32 nm

1550.12 nm

1550.92 nm

1551.72 nm

1552.52 nm

1553.33 nm

To increase the capacity of an existing CWDM fiber optic network ,1530nm and 1550nm channels can be used to insert DWDM wavelengths.

Expanding CWDM networks with DWDM channels enables to achieve a much higher data transport capacity and connect more subscribers using the same fiber optic cable and infrastructure between the network sites

Example of 8 DWDM channels added to an existing 8-channel CWDM network

Page 23: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

23© 2018 Viavi Solutions Inc.www.viavisolutions.com

RAN Deployment ScenarioArchitecture

Cell SiteMobile

Switching Center

BSC/RNC SGW/MME

Backhaul

Dis

trib

uted

RA

NRRU

(Radio Radio Unit)

BBU(Baseband Unit)

FTTA (Fiber to the

Antenna)

Central Site

Mobile Switching Center

BSC/RNC SGW/MME

Cen

tral

ized

RA

N

Backhaul

RRU

BBU Hotel

FTTA

xWDM

Cell Site

Fibers

Page 24: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

24© 2018 Viavi Solutions Inc.www.viavisolutions.com

Services with xWDM

The risks• Longer wavelengths (L-band) more sensitive to bends• Delayed service/wavelength turn up• Repeat truck rolls – at own cost (contractors)• SLA penalties if you take down other services

Challenges• Validating specific wavelength routes and individual losses• Turn-up or troubleshooting without disrupting other

services/wavelengths• Number of fibers and wavelengths, total test time

What to test• At specific CWDM & DWDM wavelengths

• OTDR and LS • Verify individual power levels – channel test• Validate End-to-End Losses through MUX and DEMUX

Page 25: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

25© 2018 Viavi Solutions Inc.www.viavisolutions.com 25© 2017 Viavi Solutions Inc.www.viavisolutions.com

Workflow & Reporting

Page 26: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

26© 2018 Viavi Solutions Inc.www.viavisolutions.com

Report Generation – Proof and Protection.

Birth Certificate – Prove Day 1 Fibre Performance and Quality of Work

Inspection and LossOTDR and Inspection

Page 27: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

27© 2018 Viavi Solutions Inc.www.viavisolutions.com

Pulling It All Together

Meter is properly set up• Firmware version• Configuration• Options deployed

Job is properly defined• Required tests• Proper limits• Named correctly

Job is properly executed• All assigned jobs completed• All tests performed/job• All tests passed

Data is properly managed• Collected upon meter sync• Organized per your org structure• Centrally available

Proper reporting available• Emailed on defined cadence• Custom/ad-hoc reports anytime• Per tech/group/region/division/…

Proper meter is available• Right model• Right options• Valid calibration

Page 28: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

28© 2018 Viavi Solutions Inc.www.viavisolutions.com 28© 2017 Viavi Solutions Inc.www.viavisolutions.com

Conclusion

Page 29: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

29© 2018 Viavi Solutions Inc.www.viavisolutions.com

FTTA - Connector Certification / Losses / OTDR• Inspect and clean fiber end faces• Inspect and clean loopback device, reference

jumpers & light source

• Perform reference loss measurement• Connect loopback device• Perform loss measurement

• If no signal – use a VFL to validate continuity

• Inspect & clean Launch cable and connect to the OTDR

• Inspect & clean Receive Cable & Non Reflective Termination and connect

• Perform OTDR Measurement

Ste

p 1

Ste

p 2

Ste

p 3

Ste

p 4

Page 30: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

30© 2018 Viavi Solutions Inc.www.viavisolutions.com

Macrocell/FTTA Cell Site Deployment Solution

BBU

Junction Box

RRU/RRH

Fiber Trunk Cable

RRU/RRH Fiber Jumper

Front-haul

Backhaul

Junction Box

Rad

io

BB

U

Page 32: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

32© 2018 Viavi Solutions Inc.www.viavisolutions.com

Questions

Contact Doug Clague:[email protected]

Page 33: Fiber to the Antenna Fiber Certification...ORL is the ratio of reflected to transmitted optical power levels for the end-to-end fiber link. This represents the combined amount of reflected

www.viavisolutions.com