2
03-09-2013 UK Moulded gratings H BxL Grid size Open area E 0 o Weight Stock item mm mm mm % x10 3 MPa kg/m 2 - 12,5 1220x3658 50x50 72 - 4 25 1220x3658 38x38 70 15 12,3 25 1007x2007 40x40 68 15 12,3 25 1007x3007 40x40 68 15 12,3 25 1007x4047 40x40 68 15 12,3 30 1220x3658 38x38 70 15 14,6 30 1007x2007 40x40 68 15 14,7 30 1007x3007 40x40 68 15 14,7 30 1007x4047 40x40 68 15 14,7 38 1220x3658 38x38 70 15 18,6 38 1007x2007 40x40 68 15 18,5 38 1007x3007 40x40 68 15 18,5 38 1007x4047 40x40 68 15 18,5 50 1220x3658 38x38 72 15 21,9 Other grid sizes and panel sizes can be ordered separately. Moulded gratings are available in several qualities. H BxL Grid size Open area E 0 o Weight Stock item mm mm mm % x10 3 MPa kg/m 2 - 30 1007x3007 20x20 42 18,9 19 38 1220x3660 19x19 44 18,9 23 Other dimensions can be supplied as required. H BxL Grid size Open area E 0 o Weight Stock item mm mm mm % x10 3 MPa kg/m 2 - 38 1220x3658 38x152 55 - 21,5 Minimesh gratings Superspan gratings B h L B h L B h L Accessories for gratings Fiberline Gratings For offshore work platforms All steel parts are in acid-proof stainless steel.

Fiberline Gratings · PDF fileMoulded gratings H BxL Grid size Open area E ... EN 50308 I SO-14122 Dimensions: Column: 1100 mm above the walking level on the landing

Embed Size (px)

Citation preview

Page 1: Fiberline Gratings · PDF fileMoulded gratings H BxL Grid size Open area E ... EN 50308 I SO-14122 Dimensions: Column: 1100 mm above the walking level on the landing

03-09-2013 UK

Moulded gratings

H BxL Grid size Open area E0o Weight Stock item mm mm mm % x103 MPa kg/m2 -

12,5 1220x3658 50x50 72 - 4 •25 1220x3658 38x38 70 15 12,3 •25 1007x2007 40x40 68 15 12,3 •25 1007x3007 40x40 68 15 12,3 •25 1007x4047 40x40 68 15 12,3 •30 1220x3658 38x38 70 15 14,6 •30 1007x2007 40x40 68 15 14,7 •30 1007x3007 40x40 68 15 14,7 •30 1007x4047 40x40 68 15 14,7 •38 1220x3658 38x38 70 15 18,6 •38 1007x2007 40x40 68 15 18,5 •38 1007x3007 40x40 68 15 18,5 •38 1007x4047 40x40 68 15 18,5 •50 1220x3658 38x38 72 15 21,9 •Other grid sizes and panel sizes can be ordered separately. Moulded gratings are available in several qualities.

H BxL Grid size Open area E0o Weight Stock item mm mm mm % x103 MPa kg/m2 -

30 1007x3007 20x20 42 18,9 19 •38 1220x3660 19x19 44 18,9 23 •Other dimensions can be supplied as required.

H BxL Grid size Open area E0o Weight Stock item mm mm mm % x103 MPa kg/m2 -

38 1220x3658 38x152 55 - 21,5 •

Minimesh gratings

Superspan gratings

B

h

L

B

h

L

B

B

b

C

h

L

B

bC

h

L

B

b

Ch

D

h

L

B

h

D

B

h

L

B

h

L

B

h

D

B

h

L

B

h

L

B

B

b

C

h

L

B

bC

h

L

B

b

Ch

D

h

L

B

h

D

B

h

L

B

h

L

B

h

D

B

h

L

B

h

L

B

B

b

C

h

L

B

bC

h

L

B

b

Ch

D

h

L

B

h

D

B

h

L

B

h

L

B

h

D

Accessories for gratings

Fiberline GratingsFor offshore work platforms

All steel parts are in acid-proof stainless steel.

Page 2: Fiberline Gratings · PDF fileMoulded gratings H BxL Grid size Open area E ... EN 50308 I SO-14122 Dimensions: Column: 1100 mm above the walking level on the landing

03-09-2013 UK

H = 1100 mm

q [N/m]

L

L

Fiberline handrail profilesFor offshore work platforms

Relation between deflection and column distance

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

Deflection [mm]

Deflection limit acc.

to ISO 14122 and

EN 50308

Recommended maximum column distance is 1,5 [m] acc. to ISO 14122 and EN 50308

Column 50x50x5 at q=300N/m

Column 50x50x5 at q=500 N/m Column 60x60x5 at q=500 N/m

Column 60x60x5 at q=300N/m

Distance between the columns, L[m]

Foot plateItem no. 120486 Grey*Item no. 120567 White

Kneerailmm 40x3 48x3Item no. 020231 - Grey*Item no. 020237 010050 White

Columnmm 50x50x5 60x60x5 Item no. 060275 060274 Grey*Item no. 060189 060237 White

EN13706 grade E23

HandrailItem no. 121605 Grey*Item no. 121606 White

EN13706 grade E23

*Fire-retardant

Handrail connectionFor connecting handrails in all angles and in both horizontal and vertical direction.

Item no. 148875

Column end capsmm 50x50x5 60x60x5 Item no. 460020 460045

Kneerail connectionFor connecting kneerails in all angles and in both horizontal and vertical direction.

Item no. 148869

Kneerail end capsItem no. 460072

Column bracketsmm 50x50 60x60 60x80Item no. 147003 147032 147035*

* With cut in 80 side

Column bracketsmm 50x50 60x60 60x80Item no. 147006 147030 147034

Column bracketsmm 50x50 60x60 Item no. 147005 -

Handrail bracketsmm L=74 L=100Item no. 147016 147022

L

Complies with: Germanischer Lloyd: Guideline for the Certification of Offshore Wind Turbines Det Norske Veritas: DNV-OS-J101 EN 50308I SO-14122 Dimensions: Column: 1100 mm above the walking level on the landing. Distance between columns preferably limited to 1500 m. The guard-rail shall include at least one intermediate kneerail. Space between kneerail and handrail as well as between kneerail and foot plate shall not exceed 500 mm.Load/Deflections: The guard-rail is to withstand a minimum line load of 300 N/m. The maximum deflection is 30 mm

Kim LindhardtTechnical Solutions Manager, Wind Turbines