Introduction

• Fire extinguishers are located throughout all buildings in the district.

• This presentation will provide you with information regarding extinguisher responsibilities, inspections, recharging, and use. Also general fire safety and procedures.

Page 3: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Agenda

• Who is responsible for site / department & other extinguishers?• Who recharges extinguishers and coordinates recharging?• When is recharging accomplished & how does it get done?• Are there required inspections?• How are fires classified?• How to prevent fires & When not to fight a fire.• How fires start & How to extinguish small fires.• How to identify the proper fire extinguisher.• How to use a portable fire extinguisher & How to inspect your extinguishers.• Different extinguishers look different.• What if only part of the extinguisher is used.• How to evacuate a burning building & What to do if someone catches on fire.• Summary.

Page 4: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Who is responsible for school site extinguishers?

• Head custodians are responsible at their respective school sites.

Page 5: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Who is responsible for department extinguishers?

• Departments have assigned individuals that are responsible.

• Departments involved are:

• Transportation / Food Service

• Head custodians should also inspect kitchen extinguishers in addition to food service personnel.

Page 6: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Who is responsible for extinguishers in other areas?

• Individuals in special areas are responsible for their extinguishers.

Areas are:• Vehicles• Warehouse• District Office• Special extinguishers (kitchen overheads), are

inspected and maintained by an outside contractor.• Periodic inspection by Head custodians is required

to supplement this.

Page 7: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Who recharges extinguishers?

• An outside company recharges all district extinguishers.

• The company currently used is Fire Masters located in Reno, Nv.

Page 8: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Who coordinates the recharging?

• The district maintenance department coordinates recharging of all extinguishers except transportation.

• The transportation supervisor coordinates all transportation extinguishers.

Page 9: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

When is recharging accomplished?

• Once a year (annually)

• The month of August is the month of outside company inspection and recharging.

Page 10: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How do I get spent extinguishers recharged?

If there is a spent extinguisher from use or vandalism:

• Call the number on the fire extinguisher tag (Fire Masters) to come out and recharge the unit(s).

• Place the necessary information in the log, (document), including when the unit was recharged.

• Notify the maintenance department of the situation in order for proper billing and tracking to occur.

Page 11: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Are There Required Inspections?

Yes• Responsible individuals must inspect

extinguishers in areas of access to the public once a week. These area include hallways and meeting areas.

• Extinguishers in areas not accessed by the public must be inspected once every three (3) months.

• Recording of dates of inspections, findings, and repairs and / or actions taken, must be documented by the responsible idividual and kept in the back of the site safety binder.

Page 12: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How Fires Are Classified

CLASS AOrdinary combustibles or fibrous material, such as wood, paper, cloth, rubber and some plastics.

Page 13: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How Fires Are Classified

CLASS B Flammable or combustible liquids such as gasoline, kerosene, paint, paint thinners and propane.

Page 14: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How Fires Are Classified

CLASS CEnergized electrical equipment, such as appliances, switches, panel boxes and power tools.

Page 15: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How Fires Are Classified

CLASS DCertain combustible metals, such as magnesium, titanium, potassium and sodium. These metals burn at high temperatures and give off sufficient oxygen to support combustion. They may react violently with water or other chemicals, and must be handled with care.

Page 16: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How To Prevent Fires

Class A — Ordinary combustibles:

Keep storage and working areas free of trash Place oily rags in covered containers.

Page 17: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How To Prevent Fires

Class B — Flammable liquids or gases: Don't refuel gasoline-powered equipment in a confined space, especially in the presence of an open flame such as a furnace or water heater. Don't refuel gasoline-powered equipment while it's hot. Keep flammable liquids stored in tightly closed, self-closing, spill-proof containers. Pour from storage drums only what you'll need. Store flammable liquids away from spark-producing sources. Use flammable liquids only in well-ventilated areas.

Page 18: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How To Prevent Fires

• Class C — Electrical equipment: Look for old wiring, worn insulation and broken electrical fittings. Report

any hazardous condition to your supervisor. Prevent motors from overheating by keeping them clean and in good

working order. A spark from a rough-running motor can ignite the oil and dust in it.

Utility lights should always have some type of wire guard over them. Heat from an uncovered light bulb can easily ignite ordinary combustibles.

Don't misuse fuses. Never install a fuse rated higher than specified for the circuit.

Investigate any appliance or electrical equipment that smells strange. Unusual odors can be the first sign of fire.

Don't overload wall outlets. Two outlets should have no more than two plugs.

Page 19: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How To Prevent Fires

Class D — Flammable metals: Flammable metals such as magnesium and titanium generally

take a very hot heat source to ignite; however, once ignited are difficult to extinguish as the buring reaction produces sufficient oxygen to support combustion, even under water.

In some cases, covering the burning metal with sand can help contain the heat and sparks from the reaction. Class D extinguishing agents are available (generally as a dry powder in a bucket or box) which can be quite effective, but these agents are rare on the campus.

If you are planning a research project using a large amount of flammable metals you should consider purchasing a five or ten pound container of Class-D extinguishing agent as a precaution.

Page 20: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How To Prevent Fires

• Class D — Flammable metals: Pure metals such as potassium and sodium react violently

(even explosively) with water and some other chemicals, and must be handled with care. Generally these metals are stored in sealed containers in a non-reactive liquid to prevent decay (surface oxidation) from contact with moisture in the air.

White phosphorus is air-reactive and will burn/explode on contact with room air. It must be kept in a sealed container with a non-reactive solution to prevent contact with air.

All of these metals are not uncommon in labs on the OU campus, but are generally only found in small quantities and accidental fires/reactions can be controlled or avoided completely through knowledge of the properties of the metals and using good judgment and common sense.

Page 21: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

When Not to Fight a Fire

Never fight a fire: •If the fire is spreading beyond the spot where it started.  •If you can't fight the fire with your back to an escape exit.•If the fire can block your only escape.  •If you don't have adequate fire-fighting equipment.

In any of these situations,

DON'T FIGHT THE FIRE YOURSELF.CALL FOR HELP.

Page 22: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How Fires Start

Fire is a chemical reaction involving rapid oxidation or burning of a fuel. It needs three elements to occur:

FUEL - Fuel can be any combustible material - solid, liquid or gas. Most solids and liquids become a vapor or gas before they will burn.

OXYGEN - The air we breathe is about 21 percent oxygen. fire only needs an atmosphere with at least 16 percent oxygen.

HEAT - Heat is the energy necessary to increase the temperature of the fuel to a point where sufficient vapors are given off for ignition to occur.

Page 23: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

When Not to Fight a Fire

• CHEMICAL REACTION - A chain reaction can occur when the three elements of fire are present in the proper conditions and proportions. Fire occurs when this rapid oxidation, or burning takes place.

Take any one of these factors away, and the fire cannot

occur or will be extinguished if it was already burning.

Page 24: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Extinguish Small Fires

• Class A - Extinguish ordinary combustibles by cooling the material below its ignition temperature and soaking the fibers to prevent re-ignition.

Use pressurized water, foam or multi-purpose(ABC-rated) dry chemical extinguishers. DO NOT USE carbon dioxide or ordinary (BC-rated) dry chemical extinguishers on Class A fires.

Page 25: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Extinguish Small Fires

• Class B - Extinguish flammable liquids, greases or gases by removing the oxygen, preventing the vapors from reaching the ignition source or inhibiting the chemical chain reaction.

Foam, carbon dioxide, ordinary (BC-rated) dry chemical, multi-purpose dry chemical, and halon extinguishers may be used to fight Class B fires.

Page 26: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Extinguish Small Fires

• Class C - Extinguish energized electrical equipment by using an extinguishing agent that is not capable of conducting electrical currents.

Carbon dioxide, ordinary (BC-rated) dry chemical, multi-purpose dry chemical and halon* fire extinguishers may be used to fight Class C fires. DO NOT USE water extinguishers on energized electrical equipment.

* Even though halon is widely used, EPA legislation is phasing it out of use in favor of agents less harmful to the environment.

Page 27: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Extinguish Small Fires

• Class D - Extinguish combustible metals such as magnesium, titanium, potassium and sodium with dry powder extinguishing agents specially designated for the material involved.

In most cases, they absorb the heat from the material, cooling it below its ignition temperature.

Page 28: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Extinguish Small Fires

• NOTE: Multipurpose (ABC-rated)chemical extinguishers leave a residue that can harm sensitive equipment, such as computers and other electronic equipment. Because of this, carbon dioxide or halon extinguishers are preferred in these instances because they leave very little residue.

ABC dry powder residue is mildly corrosive to many metals. For example, residue left over from the use of an ABC dry powder extinguisher in the same room with a piano can seriously corrode piano wires.

Carbon dioxide or halon extinguishers are provided for most labs and computer areas on campus.

Page 29: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Identify the Proper Fire Extinguisher

• All ratings are shows on the extinguisher faceplate. Some extinguishers are marked with multiple ratings such as AB, BC and ABC. These extinguishers are capable of putting out more than one class of fire.

Class A and B extinguishers carry a numerical rating that indicates how large a fire an experienced person can safely put out with that extinguisher.

Page 30: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Identify the Proper Fire Extinguisher

• Class C extinguishers have only a letter rating to indicate that the extinguishing agent will not conduct electrical current. Class C extinguishers must also carry a Class A or B rating.

Class D extinguishers carry only a letter rating indicating their effectiveness on certain amounts of specific metals.

Page 31: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Use a Portable Fire Extinguisher

• HOW TO USE A PORTABLE FIRE EXTINGUISHERRemember the acronym, "P.A.S.S."—P......Pull the Pin.A......Aim the extinguisher nozzle at the

base of the flames.S......Squeeze trigger while holding the

extinguisher upright.S......Sweep the extinguisher from side to

side, covering thearea of the fire withthe extinguishing agent.

Page 32: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Use a Portable Fire Extinguisher

• REMEMBER:• Should your path of escape be threatened

 • Should the extinguisher run out of agent

 • Should the extinguisher prove to be ineffective

 • Should you no longer be able to safely fight the fire• ...THEN LEAVE THE AREA IMMEDIATELY!

Page 33: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Inspect Your Fire Extinguishers

• Know the locations of the fire extinguishers in your work area.

Make sure the class of the extinguisher is safe to use on fires likely to occur in the immediate area.

Check the plastic seal holding the pin in the extinguisher handle. Has the extinguisher been tampered with or used before? Report any broken/missing seals/pins to the Fire Safety Unit at 325-1015.

Look at the gauge and feel the weight. Is the extinguisher full? Does it need to be recharged?

Page 34: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Inspect Your Fire Extinguishers

• Water, some foam, and dry chemical extinguishers have gauges indicating the pressure inside the extinguisher. The pressure needle should be in the "green" area (generally 100-175 lbs., depending on the type of agent).

CO2 (carbon dioxide) extinguishers are high pressure cylinders with pressures ranging from 1500 lb to 2150 lb. These extinguishers DO NOT have gauges and must be weighed by Fire Safety Unit staff to determine the amount of contents remaining.

Page 35: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Inspect Your Fire Extinguishers

• Make sure the pin, nozzle and nameplate are intact.

The Fire Safety Unit inspects and services all OU fire extinguishers on a year-round basis, but we would still encourage you to be aware of the condition of your area's extinguishers by visual inspection on a frequent basis to ensure you have a working extinguisher there when you need one.

Report any missing, empty or damaged fire extinguishers to the Fire Safety Unit (325-1015) whenever you notice any discrepancies.

Page 36: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Different Extinguishers Look Different

• Generally, you can tell with a glance which type an extinguisher is hanging on the wall, or in the cabinet, just by looking at its shape. Check the labels of the extinguishers in your area and note the color and shape/size of the extinguisher. This may help if someone runs in to help you fight a fire with the WRONG extinguisher (i.e. water on an electrical fire) - you can STOP them before they are injured or make matters worse!

Page 37: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Different Extinguishers Look Different

BC-rated multipurpose dry powder extinguishers are the most common on campus,

particularly in the corridors of academic buildings. They are almost always RED in color and have either a long narrow hose or no hose (just a short nozzle). These extinguishers are very light (5-25 lbs total weight) Halon extinguishers look virtually identical to ABC multipurpose dry chemical extinguishers.

Page 38: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Different Extinguishers Look Different

• Water extinguishers are generally only found in the dormitories and are usually SILVER (crome-metal) in color, have a flat bottom, have a long narrow hose, are quite large (2-1/2 gallons). Foam extinguishers (rare on the OU campus, nowadays) look similar and the type without gauges have a handle inset in the flat bottom (you turn the extinquisher upside down to start it and use it)

Page 39: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Different Extinguishers Look Different

CO2 (carbon dioxide) extinguishers are generally red (often yellow around aircraft or on military sites), have a LARGE "tapered" nozzle (horn), are VERY HEAVY (15-85 lbs.) -some CO2 extinguishers for aircraft hangers or special industrial use are so large as to require roll-around carts to move them. These are all high-pressure cylinders.

Page 40: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Different Extinguishers Look Different

Care should be used not to drop a CO2 cylinder; if it is damaged it can punch a hole through the nearest wall(s) and end up on the other side of campus! (The containers are quite sturdy, but don't abuse them.) CO2 cylinders do not have a pressure gauge - they must be weighed to determine the amount of contents.

Page 41: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

What If I Don’t Use all of the Extinguisher Contents?

After ANY use a BC or ABC extinguisher MUST be serviced and recharged. This is very important for home extinguishers also; YOU MUST HAVE THE EXTINGUISHER REFILLED AFTER ANY USE.

You can't "test" an extinguisher and put it back in the cabinet!

Page 42: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Evacuate a Burning Building

The last one out of the room should not lock the door, just close it. Locking the door hinders the fire department's search and rescue efforts. 

Proceed to the exit as outlined in the Emergency Action Plan. 

NEVER, NEVER use elevators under any circumstances. 

Stay low to avoid smoke and toxic gases. The best air is close to the floor, so crawl if necessary.

Page 43: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Evacuate a Burning Building

If possible, cover your mouth and nose with a damp cloth to help you breathe. 

If you work in a building with multiple stories, a stairway will be your primary escape route. Most enclosed stairwells in buildings over two stories are "rated" enclosures and will provide you a safe means of exit; don't panic descend stairs slowly and carefully.

Page 44: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

How to Evacuate a Burning Building

Once in the stairwell, proceed down to the first floor. Never go up. 

Once outside the building, report to a predetermined area so that a head count can be taken.

Page 45: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

What to do if Trapped in a Burning Building

If you're trying to escape a fire, never open a closed door without feeling it first. Use the back of your hand to prevent burning your palm. If the door is hot, try another exit. If none exists, seal the cracks around the doors and vents with anything available.

If in a dorm room, use wet towels to seal the space under the door and prevent the entry of smoke. Cracks around the door can be sealed with masking tape if necessary.

Page 46: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

What to do if Trapped in a Burning Building

If trapped, look for a nearby phone and call the fire department, giving them your exact location.

If breathing is difficult, try to ventilate the room, but don't wait for an emergency to discover that window can't be opened.

If on an upper floor and your window is of a type that CANNOT be opened, DON'T break it out- you'll be raining glass down on rescuers and people exiting the building. If you can't contact the fire department by phone, wave for attention at the window. Don't panic.

Page 47: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

What to do if Someone Catches on Fire

If you should catch on fire:

STOP - where you are

DROP - to the floor

ROLL - around on the floor

This will smother the flames, possibly saving your life.

Just remember to STOP, DROP and ROLL.

If a co-worker catches on fire, smother flames by grabbing a blanket or rug and wrapping them up in it. That could save them from serious burns or even death.

Page 48: Fire Safety & Extinguishers. Introduction Fire extinguishers are located throughout all buildings in the district. This presentation will provide you

Summary

• Fire extinguisher training is necessary to prevent harm from misuse.

• Know your evacuation plan.

• Know the location of all fire extinguishers in your building.

• There are many types of fires and all are handled differently.