34

FireClass Overview 2 - tfppemea.comtfppemea.com/en/_layouts/fsassets/Docs/Detection_FireClass... · FireClass Overview ... Detector Combined Smoke and ... • Multiple tones and flash

Embed Size (px)

Citation preview

FireClass Overview 2

Tyco Heritage and Experience

• World leading fire and security company

• Over 50 years of technological expertise

• Driving innovative technology

• First triple sensing technology

• First with Carbon Monoxide technology

• Global network of engineers in 15 R&D facilities worldwide

• Creating solutions tailored to local markets and customer needs

• Sharing technology knowledge and ideas

Tyco R&D Centres of Excellence

FireClass Overview

• FireClass is a revolutionary new class of

commercial fire detection system

• Out-of-the-box, digital open-protocol

solution, that is easy to install

• FireClass is designed to appeal to both the

end user and installer

• Easy to install

• Part of Tyco International, the world leader

in fire and security solutions

• Tyco Heritage – specialising in control

equipment for the last 50 years

• Designed and engineered in Europe

What is FireClass?

3

FireClass Overview

• Open Protocol – Openly available

- Freedom of choice

• Out of the Box – complete solution • Easy to install and configure

• One provider - One stop shop solution

• Proven technology – over 50 year Heritage

• Extensive product range

• Comprehensive back-up and support

• Unrivalled Customer Service

• Approved to all Major European Standards

Benefits of FireClass

4

FireClass Overview 5

Who needs FireClass ?

• Who need to

know about

the latest

fire detection

technology to

specify including:

• Easy to design

• Flexible

• Open Protocol

• Covers a wide

range of risks

• Comprehensive

range

Engineers Consultants Installers

• Who want an

easy to

procure and

easy to install

system including:

• Complete fire

solution from

a single provider

• Open Protocol

• Products for

all risks and

applications

End - Users

• Who need a cost

effective, reliable,

False Alarm free

Fire Detection

System including:

• Open Protocol

• Easy and flexible

to maintain

• Meets regulations

• Minimal false alarms

• Flexible

• Future proof

FireClass Overview

FireClass product range gives the flexibility and versatility for most applications

Versatile and Flexible

6

Hotels Restaurants

Schools

Hospitals

Retail

Warehouse

Nursing homes

Offices

Special Hazards

FireClass Conventional

FireClass Conventional Products

• Comprehensive range

• Low Cost 2 Zone to Multiple Zone applications

• 2 Wire variants available

• Fully approved to EN54 and CPD

• Easy to install

• Proven technology

• Full range of repeater options available

• Surface and Flush mounting variants

Conventional Range

8

General Features

FireClass Conventional Products

• 2,4 & 8 Zone versions

• Easy to install, program and use.

Key operated controls

• Panels can be surface or semi flush mounted

• 20mm cable gland breakouts

• Low standby power consumption.

• 4 Sounder circuits 4 & 8 zone, 2 on

2 zone panel. Zonal & Alert sounder

options configurable

Conventional Control Panel - Duo-Cel

9

• 1.5A switched mode power supply with

temperature compensated battery charging

• 8 Zone repeaters available with 24V or mains

operation (suitable for 4 & 8 zone panels only)

• Short circuit zone activation option (Global)

• End of Line zone resistor option

for retrofitting (Global)

General Features

FireClass Conventional Products

Conventional Control Panel - Precept EN

10

General Features

• From 2 to 32 zones

• EN54-2 / CPD approval (BSi)

• 4 alarm circuits as standard

(4 zone panel and above)

• Up to 5 fully-functional repeaters

- 2-wire RS485

• Extensive configurable facilities

for the engineer via DIL switches

• Zonal one-man test feature.

• Short Circuit to fire setting for use with older type detectors

• Panel inputs for class change, evacuate, silence alarms,

system reset

• 3 outputs for evacuate, buzzer active, disablement active

• Auxiliary supply output - monitored fuse

• Extensive expansions

• Optional timer clock/counter module

• Optional Foreign Language text inserts available

• Optional Semi-flush and fully flush mounting bezels available

FireClass Conventional Products

Gas Suppression Release - Prescient III

11

General Features

• 1st stage, 2nd stage, 3rd stage and gas

discharged outputs

• Single or double knock operation

• Pre-discharge delay adjustable from 0 to

60 seconds with visible countdown timer

• Discharged indication with or without pressure switch

• Option for rapid buzzer pulse when gas imminent

• One man zone and sounder test General Features

• From 2 to 32 zones

• EN54-2 / CPD approval (BSi)

• 4 alarm circuits as standard

(4 zone panel and above)

• Up to 5 fully-functional repeaters

- 2-wire RS485

• Extensive configurable facilities

for the engineer via DIL switches

• Zonal one-man test feature.

FireClass Conventional Products

Features SLU1 SLU2 SLU3

Two core data link between panel and status unit

Two core power connection between panel and status unit

Indication of events/status only unit

Manual Release

Auto/Manual Keyswitch

Countdown timer

Abort and hold off switch

Gas Suppression Release – Status Indicator Units

12

FireClass Conventional Products

• Extensive range for all applications and risks

• Low profile, discreet and unobtrusive

• Superior proven performance and reliability

• Designed for fast, easy installation

• Integral alarm LED

Conventional Detection

13

Model Type Description

601PH High Performance Optical Detector

Combined Smoke and Heat ideal for use with slow smouldering fires or open flaming fires.

601CH Enhanced Carbon Monoxide Detector

Provides very early warning for slow smouldering fires ideal for sleeping risks.

601P Optical Smoke Detector Ideal for use with slow burning or smouldering fires

601HR/F Heat Detector A fixed temp or rate of rise heat detector ideal for use where smoke detectors cannot be situated.

601F Infra Red Flame Detector Ideal for protecting large open areas without sacrificing speed of response to flaming fires

13

FireClass Conventional Products

• Extensive range

• Standard and Diode Bases options

• Sounder Base with Adjustable volume

• Designed for fast, easy installation

• Remote alarm LED

• Relay Base option

Conventional Detection Ancillaries

14

Model Type Description

4 B Conventional Detector Base Standard Conventional detector mounting base

4B-D Conventional Diode Base Standard Conventional Detector base with Diode.

601 SB Conventional Sounder Base Conventional Sounder base with adjustable volume.

601 SBD Conventional Sounder Base with Diode

Conventional Sounder base with Diode and Adjustable volume

MC 600 Relay Base Conventional relay base

CTA Ceiling Tile Adaptor Kit Easy fit adaptor for Ceiling tile mounting of Detectors

14 14

FireClass Conventional Products

• Surface or Flush mounting.

• Test Key for easier commissioning and maintenance

• Optional Transparent hinged cover

• Hazardous area models available

• IP67 model for external use

• 2 Wire version for use with Duo-Cel 2 wire

Conventional Sounders • Extensive range of Bells and electronic sounders

• High sound output at low current

• Adjustable volume variants available

• Easy to install – reduces installation cost

• Weatherproof variants for external use

Conventional Call points

15 15

General Features

General Features

FireClass Addressable

• Digital addressable Open protocol

• 250 addresses per loop (Lite 125)

• Full EN 54 / CPD approvals.

• Easy to program

“Out of the box” simplicity

Quick Start guide.

• Fully networkable Panels

Programmable over the network.

• PC based Interactive Graphical

User Interface available.

• Extensive range of Detection

including Multi and Tri –Sensors

• Sensors approved in all

operating modes.

• Comprehensive range of Loop

Powered Sounders/Beacons.

• Full range of loop I/O modules

FireClass Addressable Range - Overview

17 17 FireClass Addressable Products

FireClass Addressable Products

• Digital Open protocol

• High resilience to electrical interference / earthing issues

• Supports wide variety of cables and installations

• Supports interrupts for priority devices eg. Callpoints

• 250 Addresses per loop ( Lite version -125)

• Full Sychronisation of loop sounders

• 500 mA loop current

• Max. 2 Km loop length

• Multiple modes of device operation

• Central processing of loop data incorporating Multiple

detection modes and Algorithms and Fuzzy logic.

• High immunity to electrical interference.

• Interrupt processing for fast response.

FireClass Digital Open Loop Protocol Features

18 18

Fireclass Lite - Single Loop Panel

19 FireClass Addressable Products 19

• Up to 125 addresses.

• Single loop non networkable

• 640 Character Display

• 32 Zone LED’s

• Integral 2.5A Power Supply unit.

• Out of the box “Quick Start” configuration

• Displays temperature, CO level and smoke

level at point in alarm

• 3000 event log

• Manual and Automatic walk test and

reporting functions

• Automatic battery test

• Detector service functions

General Features

General Features

Addressable – One Loop FireClass 32

20 FireClass Addressable Products 20

• Up to 250 addresses.

• Single Loop Networkable (up to 24 Panels)

• EN54 Part 2&4 and CPD approved.

• 640 Character Display

• 32 Zone LED’s

• Integral 2.5A Power supply unit

• Permanently display of system status

• Displays sensors temperature, CO level and smoke

level at point in alarm

• 3000 event log

• Manual and automatic walk test and reporting functions

• Detector service functions

• Extensive I/O Expansion options

General Features

Addressable Two – Four Loop FireClass 64

21

FireClass Addressable Products 21

• Up to 1000 addresses.

• Up to 250 addresses per loop

• Multi Loop Networkable (up to 24 Panels)

• EN54 Pt 2&4 and CPD approved

• 640 Character Display

• 64 Zone LED’s

• Integral 5A Power supply unit

• Displays sensors temperature, CO level and smoke

level at point in alarm

• 3000 event log

• Manual and automatic walk test and reporting functions

• Detector service functions

• Extensive I/O Expansion options

Addressable – Two or Four Loop FireClass 240

General Features

22

FireClass Addressable Products 22

• Up to 1000 addresses.

• Up to 250 addresses per loop

• Multi Loop Networkable (up to 24 Panels)

• EN54 Pt 2&4 and CPD approved

• 640 Character Display

• 240 Zone Non-LED

• Integral 5A Power supply unit

• Displays sensors temperature, CO level and

smoke level at point in alarm

• 3000 event log

• Manual and automatic walk test and reporting functions

• Detector service functions

• Extensive I/O Expansion options

FireClass Addressable Repeater Panels

23 FireClass Addressable Products 23

General Features

• 32, 64 and 240 Zone repeaters available

• Small compact enclosure

• Up to 7 repeaters per panel

• Integral 2.5A Power Supply

• AC and DC versions available

• Comprehensive Programming Software

• Simple and Intuitive

• Fast Panel set up

• Text / Device / Zone allocation

• Cause Effect Programming

• Import of project data

• Update Panel Firmware

• Export Date to FCG Graphics System

• Upload via Serial port and Programming lead

FireClass Express Software

24 FireClass Addressable Products 24

General Features

Network Platform

Networking Platform – Utilising the TLI800EN

25

General Features

• EN54 Approved

• Fault tolerant peer to peer networking

• Up to 24 Panel Network

• Up to 24,000 points maximum

• Programming can be achieved across the Network

• Allows connection to other networked panels

• Allows connection to FireClass Graphics System

• Supports Shielded twisted pair cabling

• EN54 and CPD approved

• Wide range including Multi and Tri Sensors

• FireClass HPO detection algorithms

• FireClass CO detection technology

• Up to 250 detectors per loop

• Extended service life

• Drift Compensation

• Fire, isolate and fault LED indications

• Standard base and isolator base available

Addressable Detectors FC460

26

A combined total of 22 approved modes and sensitivities to choose from

Model Type Description

FC 60PH High Performance Optical Detector

Combined Smoke and Heat ideal for detecting slow smouldering fires or open flaming fires.

FC460P Optical Smoke Detector Ideal for detecting slow burning or smouldering fires

FC460H Heat Detector A fixed temp or rate of rise heat detector ideal for use where smoke detectors cannot be situated.

F460PC Triple Sensing Detector Smoke, Heat and Carbon Monoxide

FireClass Addressable Products 26

• Loop powered - reduced installation costs

• High sound output characteristics

• Low current consumption

• Synchronisation of Sound output

• Clean lines, modern styling

• Easy to install, low installation costs

• Multiple tones and flash rate to suit individual requirements

• Integral line isolator

Addressable Sounders / Beacon Bases

27

Model Type Description

FC430LPSB Addressable Sounder Base Loop powered Addressable Sounder base with integrated base and Loop Isolator

FC430LPASB Addressable Sounder / Beacon Base

Loop powered Addressable Sounder Beacon base with integral base and Loop Isolator.

FireClass Addressable Products 27

• Loop powered - reduced installation costs

• High sound output characteristics

• Low current consumption

• Synchronisation of sound output

• Easy to install, low installation costs

• Weather proof units for outdoor use

• Multiple tones and flash rate to suit individual requirements

• Integral line isolator

Addressable Sounders

28

Model Type Description

FC410LPSY(R/W) Loop powered Sounder Addressable Loop Powered Sounder Red (R) White (W)

FC410LPSY Weatherproof Loop Powered Sounder

IP65 Addressable loop Powered Sounder Red

FC410LPAVR Loop powered Sounder / beacon

Addressable Loop Powered Sounder Beacon Red

FC410LPAV Weatherproof Loop Powered Sounder Beacon

IP65 Addressable Loop Powered Sounder Beacon Red

FireClass Addressable Products 28

• Integral LED indicator for easy identification of operation

• Surface or Flush Mounting

• Test key facility, speeds maintenance visits

• Optional transparent hinged cover

• IP67 Waterproof models for external applications

Addressable Call Points

29

Model Type Description

FC420CP Indoor Call Point Manual Call Point – Internal use

FC421CP Outdoor Call Point Manual Call Point IP 67 – External Use

FireClass Addressable Products 29

• Loop Powered.

• Built in loop isolator.

• Standard Housing

• Detachable connectors

Addressable Quad Modules

30

Model Type Description

FC410QMO Quad Output Module 4 x monitored Outputs that can be configured for spur or loop wiring

FC410QIO Quad I/O Module 4 x Monitored Inputs and 4x Volt free relay outputs

FC410QRM Quad Relay Module 4 x Volt free relay outputs – supply to relays can be monitored

FireClass Addressable Products 30

• Wide range.

• Comprehensive input / Output functions.

• Loop Powered where applicable.

• Easy connection terminals.

• Compact enclosures.

• LED indication.

Addressable Ancillary Modules

31

Model Type Description

FC410LI Line Isolator Module Short Circuit Isolator

F410MIM Mini Input Module Single Input – from N/O or N/C contacts

FC410CIM Contact Input module 2 Inputs – From N/O or N/C contacts

FC410DIM Detector Input Module Zone Input – supports 1 Zone of Conventional Detectors

FC410SIO Single Input / Output Module 1 Input and 1 Output

FC410MIO Multiple Input / Output Module 3 Inputs and 2 Outputs

FC410BDM Beam Detector module Connects Fireray 5000 to loop

FireClass Addressable Products 31

• Fast and accurate Address programming of Detectors

• Fast and accurate programming of ancillary devices

such as Loop Powered Sounders and Interface

modules

• Verification of Detector operation and condition

• convenient backlight

• Complete with charger, batteries & programming lead

for sounders / interfaces

• Undongled - no password or expiry

Loop Service Programmer FC490ST

FireClass Addressable Products 32

General Features

• Graphical Interface with addressable

control panels and Network

• High resolution detailed map of site

linked to floor plans

• Intuitive multi layered mapping

• Interactive Control of Panels / System

• Extensive event logging and Alarm

management tools.

FireClass Graphics

33 FireClass Addressable Products 33

General Features