Upload
trankhanh
View
219
Download
1
Embed Size (px)
Citation preview
Flamanville 3
December 15th, 2011
AIEA
Flamanville 3 - NUEU - PH - 111215 - P 2© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom4 Sectors (Total Sales 2010/2011)
Flamanville 3 - NUEU - PH - 111215 - P 3© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
AlstomIn the Top 3 in Its Main Activities
Flamanville 3 - NUEU - PH - 111215 - P 4© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom Human Resources96,500 employees in over 70 countries
11% 62%
17%6%
4%
Group
Power Sector
58%
22%1%
7%
12%
Flamanville 3 - NUEU - PH - 111215 - P 5© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom Power
��� ������������� ����������� � ����
� ����� � ���������� ��
Flamanville 3 - NUEU - PH - 111215 - P 6© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom in nuclear
Nuclear Island
Any reactor supplier
Turbine Island
Alstom
Nuclear Island + Turbine Island + BoP = Power Plant
Balance of Plant
Project specific(including Alstom Grid)
Flamanville 3 - NUEU - PH - 111215 - P 7© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
ARABELLE™ Steam TurbinePedigree
Auguste Rateau(1863-1930)
ARABELLE The maiden name is an acronym for
•ALSTOM The Leading supplier for Turbine Island equipment of Nuclear Power Plant
•RATEAU Auguste Rateau is the father of multi-stage impulse turbine technology. The RATEAU Company joined Alstom in 1976
•BELFORT The location of the factory in France where theARABELLE steam turbines are produced
•LEVALLOIS Alstom's Headquarters near Paris and where Alstom Nuclear Activity is based
Flamanville 3 - NUEU - PH - 111215 - P 8© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
ARABELLE™ Steam TurbineDesign for Performance
���������������� ����������������
MSRMSR
ARABELLEunique configuration�������������������������������� �������������������������������� ��������������������������������
MSRMSR
~70b 290°C
10b270°C
3b150°C
60% of single flow steam expansion
Flamanville 3 - NUEU - PH - 111215 - P 9© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 - layout
Shaft line:mass 1100 tlength 70 mdiameter 6,5 mspeed 1500tr/mn
Steam: Input 75 bar / 291 °C Output 44 mbar / 31 °C
Power:Input turbine 4524 MWthOutput generator 1680/1750 MWe
Voltage 23 000 V
Configuration:
Turbine: 1 module HIP + 3 modules LPGenerator: 4 poles, 3 phasesMoisture separator re-heater: 2 modules
Flamanville 3 - NUEU - PH - 111215 - P 10© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 - package
Turbo-Generator Package and Balance of Plant for European Pressurized Reactor / 1750 MW
− Steam turbine, auxiliaries and I&C system (regul./security).− Generator, auxiliaries and I&C system (AVR).
− Moisture separator re-heater.− Condenser.− Feed water tank− HP heaters, LP heaters.
− Vacuum system, Turbine bypass.− Steam and water piping.− Cooling water system, Compressed air distribution.− Extracting pumps.− Isolated phase bus, electrical cabling.
− Turbine hall installation: turbo generator and mechanical & electrical BoP,
Flamanville 3 - NUEU - PH - 111215 - P 11© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 - project management
Generator Heat ExchangersSteam Turbine Extraction pumps
ALSTOM Power Nuclear
Mechanical Equipment
----BOP-M Erection &
Commissioning
Turbo-GeneratorErection &
Commissioning
Electrical cabling----
BOP-E Erection & Commissioning
Flamanville 3 - NUEU - PH - 111215 - P 12© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – key dates
• Contract signed in September 2006.
• Engineering achieved.
• Manufacturing achieved.
• Erection ongoing:− Last site delivery of main equipment in June 2011.− Average of 400 people during the last months
• Erection planned to be achieved at the mid-2012.
• Preservation, commissioning from mid 2012 to 2016.
• Commercial operation date planned in 2016.
Flamanville 3 - NUEU - PH - 111215 - P 13© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
July 2010
Flamanville 3 - NUEU - PH - 111215 - P 14© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
December 2010
Flamanville 3 - NUEU - PH - 111215 - P 15© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
March 2011
Flamanville 3 - NUEU - PH - 111215 - P 16© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
August 2011
Flamanville 3 - NUEU - PH - 111215 - P 17© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
November 2011
Flamanville 3 - NUEU - PH - 111215 - P 18© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Turbine hall progress
Preservation start
Flamanville 3 - NUEU - PH - 111215 - P 19© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Site feed back
Short term evolution
Modular approachStick built assembly of equipment in lube oil room, chemical injection room, …
Use of electronic pad to facilitate information flow Extensive use of paperwork on site
LP exhaust hood assembled on a dedicated platform oustide the Turbine Hall
LP exhaust hood assembled at the operating floor: high mobilisation of the main crane
MSR delivered fully assembled on site:•Open top installation with special crawler crane•Erection with main turbine hall travelling crane
MSR final assembly on site: complex and high mobilisation of the main crane
Evolution Flamanville 3 actual
www.alstom.com
Flamanville 3 - NUEU - PH - 111215 - P 21© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – turbo generator package
Flamanville 3 - NUEU - PH - 111215 - P 22© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Flamanville 3 – Concrete Volute Pump
2 pumps x 30 m3/s (maxi 35)
Flamanville 3 - NUEU - PH - 111215 - P 23© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Key componentsHeat exchangers for nuclear plants
Moisture separator reheater (MSR)
LP heater
HP heater
Condenser
Nuclear purification system (NPS)
High velocity separators (HVS)
Auxiliary water/watercoolers
Feedwater tankand deaerator
1
1
2
2 3
4
4
5
5
3
Flamanville 3 - NUEU - PH - 111215 - P 24© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Key components Pump solutions for nuclear plants
Concrete volutecirculating water pump
Condensateextraction pump
Intermediatecooling pump
Essentialcooling pumpOpen/closed loopcooling pumpResidual heatremoval pump
Feedwater pump Vacuum pump
1
1
2
2 3
3
45
54
76
6
7
8
8
Flamanville 3 - NUEU - PH - 111215 - P 25© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Key components The steam turbine for any reactor
ARABELLE 1000: from 900 to 1400 MWe (50 and 60Hz)
ARABELLE 1700: from 1300 to 1800 MWe (50 and 60Hz)
Fit all nuclear reactors and site conditions
Reactor NSSSsupplier
Reactortype
ARABELLE model
EPR Areva NP PWR 1700
ESBWR GE-HITACHI BWR 1700
APWR MHI PWR 1700
AB1600 Toshiba BWR 1700
APR1400 KEPCO PWR 1700
ABWR GE-HITACHI BWR 1700
KERENA Areva NP BWR 1000
AP1000 Westinghouse PWR 1000
MIR1200 ROSATOM PWR 1000
ATMEA1 AREVA/MHI PWR 1000
VVER1000 ROSATOM PWR 1000
CPR1000 CGNPC PWR 1000
ACR1000 AECL PHWR 1000
Other reactors as appropriate
STN series for reactors range < 900 MWe
Flamanville 3 - NUEU - PH - 111215 - P 26© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom GroupOrders 2010/11 by destination
Flamanville 3 - NUEU - PH - 111215 - P 27© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom Power Headcount48000 employees in 70 countries
Flamanville 3 - NUEU - PH - 111215 - P 28© ALSTOM 2011. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom PowerOver 41 GW in execution