Pirani Gauge with Nickel Filament APN 2004 The adixen Pirani gauge APN 2004 with the standard Tungsten filament is a reliable and cost effective solution for general industral vacuum applications and also in research and development. Certain applications require a filament with improved resistance against corrosive gases. To address these applications adixen offers a new active Pirani gauge, the APN 2004. APPLICATIONS The APN 2004 is the best choice in all vacuum applications where the accuracy of a Pirani gauge is required but a Tungsten filament will suffer from corrosive gases or process by-product. • Industrial drying processes - outgassing of monomers or traces of acids • Freeze drying - high water vapour content • Sterilization - water vapour at high temperatures, Hydrogen peroxide • Reactive sputtering - Oxygen plasma • Fabrication of nano - structures - Silicon and Carbon chemistry PRODUCT BENEFITS The APN 2004 is equipped with a filament made of Nickel (Ni) instead of the standard Tungsten (W) filament used on the AP 2004. • Improved resistance in atmospheres with corrosive gases (except with high concentrations of Cl and F) • Considerably longer filament lifetime in high water vapour environments • Withstands sterilization processes in medical and pharmaceutical applications • Can replace AP 2004 without modification of circuitry, including setpoints • Fully integrated into the Series 2000 vacuum gauges family Adixen by Alcatel Vacuum Technology IMPROVED RESISTANCE TO CORROSIVE GASES AND WATER VAPOUR

Flyer the Adixen 2000 Series Vacuum Gauges

  • Upload
    pradung

  • View
    257

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Flyer the Adixen 2000 Series Vacuum Gauges

Pirani Gauge with Nickel Filament

APN 2004

The adixen Pirani gauge APN2004 with the standardTungsten filament is a reliableand cost effective solution forgeneral industral vacuumapplications and also inresearch and development.

Certain applications require afilament with improvedresistance against corrosivegases. To address theseapplications adixen offers anew active Pirani gauge, theAPN 2004.

APPLICATIONS

The APN 2004 is the bestchoice in all vacuumapplications where the accuracyof a Pirani gauge is requiredbut a Tungsten filament willsuffer from corrosive gases orprocess by-product.

• Industrial drying processes -outgassing of monomers ortraces of acids

• Freeze drying - high watervapour content

• Sterilization - water vapour athigh temperatures, Hydrogenperoxide

• Reactive sputtering - Oxygenplasma

• Fabrication of nano -structures - Silicon and Carbonchemistry

PRODUCT BENEFITS

The APN 2004 is equipped witha filament made of Nickel (Ni)instead of the standardTungsten (W) filament used onthe AP 2004.

• Improved resistance inatmospheres with corrosivegases (except with highconcentrations of Cl and F)

• Considerably longer filamentlifetime in high water vapourenvironments

• Withstands sterilizationprocesses in medical andpharmaceutical applications

• Can replace AP 2004 withoutmodification of circuitry,including setpoints

• Fully integrated into the Series2000 vacuum gauges family

Adixen by Alcatel Vacuum Technology

IMPROVED RESISTANCE TO CORROSIVE GASES AND WATER VAPOUR

Page 2: Flyer the Adixen 2000 Series Vacuum Gauges

Publication: Alcatel Vacuum Technology - Part Number 791662 - 03/2009 - All information can be modified without prior notice.

Measurement principle thermal conduction

Measurement range 5·10-4 - 1000 mbar

Accuracy 15 % of reading

Repeatability 2 % of reading

VACUUM MEASUREMENT

ORDERING INFORMATION APN 2004

Power supply

Voltage

Consumption max.

24 VDC (14 - 30 VDC)(tolerance ripple : below 2 Vp-p)

< 1 W

Analog output signal

Measurement range

Pressure signal

Error Signal

Minimum load

Cable length max.

Type of protection

2.2 V - 8.5 V

logarithmic 1 V / decade

< 0.1 V or = 0.4 V

100 kΩ

200 m (0.34 mm² )

IP40

ELECTRICAL SPECIFICATIONS

Set points

Dry contacts (2) 1 A 30 VDC

Temperature

Storage

Operation

Bakeout

Bakeout with high temp. O-Ring

- 20 °C / +70 °C

+5 °C / +60 °C

< 150 °C (without electronics)

< 300 °C (without electronics)

ENVIRONMENTAL SPECIFICATIONS

Pressure max. 10 bar*

DN 16 ISO KF, Output 0 - 10 V with 2 set-points 115 244

Compatible Controllers

ACS 2000 single channel controller with numerical display

ACM 2000 triple channel controller with graphical display

Measuring cable 5 m -10 m - 20 m

112711

112712

112751 – 112752 - 112753

Accessories

Filter DN 16 ISO KF 20 µm 305225

COMPATIBLE CONTROLLERS

• Stainless steel SUS304, SUS316

• Nickel, Fe/Ni

• Al2O3

Materials in contact

with vacuum

ACS 2000 ACM 2000

Pirani Gauge with Nickel Filament

APN 2004

Alcatel Vacuum Technology France98, avenue de Brogny - BP 2069 - 74009 ANNECY CEDEX - FRANCE - Tel.: (33) (0) 4 50 65 77 77 - Fax: (33) (0) 4 50 65 77 89

www.adixen.com

KoreaAlcatel VacuumTechnology KoreaTel: (82) 31 206 6277Fax: (82) 31 204 6279

ChinaAlcatel VacuumTechnology ShanghaiTel: (8621) 5027 0628Fax: (8621) 3895 3815

NetherlandsAlcatel VacuumTechnology NetherlandsTel: (31) 345 478 400Fax: (31) 345 531 076

France (Headquarters)Alcatel VacuumTechnology FranceTel: 33 (0)4 50 65 77 77Fax: 33 (0)4 50 65 77 89

SingaporeAlcatel-Lucent SingaporeTel: (65) 6254 0828Fax: (65) 6254 7018

GermanyAlcatel HochvakuumTechnik GmbHTel: (49) 9342 96 10 0Fax: (49) 9342 96 10 30

SwedenAdixen Scandinavia Tel: (46) 13 35 59 00Fax: (46) 13 35 59 01

IndiaAlcatel Vacuum Technology IndiaTel: (91) 124 473 7777 Fax: (91) 124 473 7799

TaiwanAlcatel VacuumTechnology TaiwanTel: (886) 3 5599 230Fax: (886) 3 5599 231